SLAC Magnetic Measurements Date: 07-27-2020 Time: 09:17:39 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_013 DATASET Number: 1 Tuning Stage: Tuning Run Number: 3 Measurement Type: PM Center Operator: YL Comment: fiducialization ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000691 -0.033357 0.516549 UPM 2 0.000535 -0.027022 1.364983 DPM 3 -0.000289 -0.027001 5.049654 DRM 4 -0.000093 -0.032889 5.836266 UPM 2 0.000535 -0.027025 1.364966 DPM 3 -0.000294 -0.026967 5.049620 DRM 4 -0.000093 -0.032896 5.836267 URM 1 0.000690 -0.033359 0.516545