SLAC Magnetic Measurements Date: 08-01-2019 Time: 15:30:19 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_007 DATASET Number: 1 Tuning Stage: Tuning Run Number: 5 Measurement Type: Long Coil Scans Operator: VV Comment: tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_Y 0.000E-03 -0.566E-06 -27.205E-06 12.00000 11.99995 5.99720 11.99980 5.99690 11.99990 5.99710 11.99975 5.99690 I2Y_VS_Y 0.000E-03 -0.505E-06 -24.268E-06 12.00000 11.99980 5.99720 11.99960 5.99690 11.99985 5.99720 11.99960 5.99690 I2Y_VS_Y 0.000E-03 -0.490E-06 -23.576E-06 12.00000 11.99985 5.99720 11.99950 5.99680 11.99985 5.99710 11.99955 5.99680