SLAC Magnetic Measurements Date: 08-01-2019 Time: 14:49:58 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_007 DATASET Number: 1 Tuning Stage: Tuning Run Number: 2 Measurement Type: Long Coil Scans Operator: VV Comment: tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_Y 0.000E-03 -0.164E-06 -2.180E-06 7.25000 7.24990 3.63100 7.24965 3.63190 7.24990 3.63090 7.24955 3.63180 I1Y_VS_Y 0.000E-03 -0.017E-06 -0.225E-06 7.25000 7.24975 3.63100 7.24935 3.63170 7.24980 3.63100 7.24935 3.63170