SLAC Magnetic Measurements Date: 07-01-2019 Time: 16:34:15 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_006 DATASET Number: 1 Tuning Stage: Tuning Run Number: 11 Measurement Type: Long Coil Scans Operator: VV Comment: tuning Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_Y 0.000E-03 1.173E-06 -94.172E-06 7.30000 7.29970 3.65310 7.29970 3.65630 7.29970 3.65310 7.29975 3.65630 I2X_VS_Y 0.000E-03 1.087E-06 -87.276E-06 7.30000 7.29960 3.65310 7.29965 3.65620 7.29960 3.65310 7.29965 3.65620 I2X_VS_Y 0.000E-03 1.742E-06 -139.872E-06 7.30000 7.29960 3.65310 7.29955 3.65620 7.29960 3.65310 7.29955 3.65620 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2X_VS_Y 0.000E-03 1.353E-06 -108.610E-06 8.00000 7.99990 4.00280 8.00020 4.00460 7.99995 4.00280 8.00030 4.00460