SLAC Magnetic Measurements Date: 07-09-2019 Time: 11:01:52 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_004 DATASET Number: 1 Tuning Stage: Tuning Run Number: 1 Measurement Type: PM Center Operator: VV Comment: initial ------------------------------------------------------------- Magnet PM number X Y Z m m m ------------------------------------------------------------- URM 1 0.000724 -0.033281 0.516665