SLAC Magnetic Measurements Date: 03-25-2019 Time: 14:23:32 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_002 DATASET Number: 1 Tuning Stage: Tuning Run Number: 2 Measurement Type: Long Coil Scans Operator: VV Comment: checking after coil installment Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 0.777E-06 -17.260E-06 9.00000 9.00030 4.49932 9.00035 4.50000 9.00030 4.49932 9.00035 4.50010 I1Y_VS_X 0.000E-03 0.830E-06 -18.448E-06 9.00000 9.00035 4.49942 9.00040 4.50000 9.00040 4.49942 9.00040 4.50010 I1Y_VS_X 0.000E-03 0.759E-06 -16.864E-06 9.00000 9.00045 4.49942 9.00040 4.50010 9.00040 4.49942 9.00040 4.50010 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_X 0.000E-03 4.894E-06 108.728E-06 9.00000 9.00045 4.49942 9.00045 4.50010 9.00045 4.49942 9.00040 4.50010 I1X_VS_X 0.000E-03 5.033E-06 111.829E-06 9.00000 9.00050 4.49942 9.00045 4.50010 9.00050 4.49942 9.00045 4.50020 I1X_VS_X 0.000E-03 4.856E-06 107.889E-06 9.00000 9.00050 4.49942 9.00050 4.50020 9.00050 4.49942 9.00045 4.50010