SLAC Magnetic Measurements Date: 11-18-2020 Time: 10:57:32 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: Calib_PC33408 Serial Number: PC33408 Run Number: 50 Measurement Device: WalkerVs Operator: sda Comment: Start of Full Tunnel Run 13. Turned on 25 minutes ago, warming up. 10:57:35 Ambient Measurement Device(s) Being Used, type = None 10:57:35 Magnet Voltage Measurement Device(s) Being Used, type = None 10:57:35 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 10:57:35 XMAG Device(s) Being Used, type = None 10:57:35 Ambient Measurement Device(s) Being Used, type = None 10:57:35   Voltage Measurement, V = 0.000000 V 10:57:36 Temperature Measurement, Probe Number = 0, T = 20.360000 C 10:57:36 Temperature Measurement, Probe Number = 1, T = 20.362000 C 10:57:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.36 P2 = 3458_Meas_Junction, Value = 20.36 10:57:36 Integrated Voltage Measurement... 10:58:01 Voltage Offset Correction: v_off_ini = -0.000028006 V, v_off_fin = -0.000028174 V 10:58:01 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099598328 Vs 10:58:01 Integrated Voltage Measurement... 10:58:26 Voltage Offset Correction: v_off_ini = -0.000027104 V, v_off_fin = -0.000026736 V 10:58:26 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099598624 Vs 10:58:27   Voltage Measurement, V = 0.000000 V 10:58:27 Temperature Measurement, Probe Number = 0, T = 20.334000 C 10:58:28 Temperature Measurement, Probe Number = 1, T = 20.382000 C 10:58:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.33 P2 = 3458_Meas_Junction, Value = 20.38 10:58:28 Integrated Voltage Measurement... 10:58:53 Voltage Offset Correction: v_off_ini = -0.000025285 V, v_off_fin = -0.000025094 V 10:58:53 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099598807 Vs 10:58:53 Integrated Voltage Measurement... 10:59:18 Voltage Offset Correction: v_off_ini = -0.000023486 V, v_off_fin = -0.000021736 V 10:59:18 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099593546 Vs 10:59:19   Voltage Measurement, V = 0.000000 V 10:59:19 Temperature Measurement, Probe Number = 0, T = 20.319000 C 10:59:20 Temperature Measurement, Probe Number = 1, T = 20.411000 C 10:59:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.32 P2 = 3458_Meas_Junction, Value = 20.41 10:59:20 Integrated Voltage Measurement... 10:59:45 Voltage Offset Correction: v_off_ini = -0.000021343 V, v_off_fin = -0.000021231 V 10:59:45 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099598733 Vs 10:59:45 Integrated Voltage Measurement... 11:00:11 Voltage Offset Correction: v_off_ini = -0.000020048 V, v_off_fin = -0.000019125 V 11:00:11 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099601372 Vs 11:00:12   Voltage Measurement, V = 0.000000 V 11:00:12 Temperature Measurement, Probe Number = 0, T = 20.304000 C 11:00:13 Temperature Measurement, Probe Number = 1, T = 20.443000 C 11:00:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.30 P2 = 3458_Meas_Junction, Value = 20.44 11:00:13 Integrated Voltage Measurement... 11:00:38 Voltage Offset Correction: v_off_ini = -0.000018764 V, v_off_fin = -0.000018029 V 11:00:38 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099600141 Vs 11:00:38 Integrated Voltage Measurement... 11:01:03 Voltage Offset Correction: v_off_ini = -0.000017825 V, v_off_fin = -0.000017636 V 11:01:03 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099600834 Vs 11:01:04   Voltage Measurement, V = 0.000000 V 11:01:05 Temperature Measurement, Probe Number = 0, T = 20.304000 C 11:01:05 Temperature Measurement, Probe Number = 1, T = 20.472000 C 11:01:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.30 P2 = 3458_Meas_Junction, Value = 20.47 11:01:05 Integrated Voltage Measurement... 11:01:31 Voltage Offset Correction: v_off_ini = -0.000016645 V, v_off_fin = -0.000016844 V 11:01:31 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099599882 Vs 11:01:31 Integrated Voltage Measurement... 11:01:58 Voltage Offset Correction: v_off_ini = -0.000015608 V, v_off_fin = -0.000015719 V 11:01:58 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.099601269 Vs