SLAC Magnetic Measurements Date: 10-12-2022 Time: 17:53:54 Project: LCLS-II Magnet Type: Quad Magnet Name: 4266 Serial Number: Run Number: 1 Measurement Device: 1DQB26_DQB Operator: sda Comment: Integrated gradient vs current from -6 to 6 to -6 amps in 1 amp steps. Centers calculated with background dipole subtracted. Magnetic Center Data Time MAIN +/- sigma X sigX Y sigY (A) (microns) (microns) --------- ------------+---------- --------+-------- --------+-------- 20:05:25 -6.0014 0.0000 -16.708 -891.09 20:44:29 5.9997 0.0000 -82.638 -943.95