Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0923 262.7580 -0.6819 -0.0574 0.5087 7 333.0947 262.7605 -0.6840 -0.0558 0.0852 Mean 333.0935 262.7593 -0.6830 -0.0566 0.2969 Std 0.0017 0.0018 0.0015 0.0011 0.2994 Error 0.00378 0.00168 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -11.4469 4.3373 0.6777 30.0169 8.9354 4.0559 7 -9.2569 5.4473 4.8077 32.6169 11.3274 6.6461 Mean -10.3519 4.8923 2.7427 31.3169 10.1314 5.3510 Std 1.5485 0.7849 2.9203 1.8385 1.6914 1.8316