Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0878 262.7588 0.0763 -0.8187 -0.0926 7 333.0880 262.7624 0.0771 -0.8549 -0.3406 Mean 333.0879 262.7606 0.0767 -0.8368 -0.2166 Std 0.0002 0.0025 0.0005 0.0256 0.1753 Error 0.00382 0.0017 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -18.7469 5.3873 1.3777 28.4269 4.4311 4.9355 7 -17.9668 6.0972 7.8976 28.1169 4.6783 8.4916 Mean -18.3569 5.7423 4.6376 28.2719 4.5547 6.7136 Std 0.5516 0.5020 4.6103 0.2192 0.1748 2.5145