Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0857 262.7589 -0.0987 -1.1809 -7.2029 7 333.0878 262.7577 -0.1041 -1.0949 -7.4444 Mean 333.0868 262.7583 -0.1014 -1.1379 -7.3236 Std 0.0015 0.0009 0.0038 0.0608 0.1708 Error 0.00362 0.00137 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -10.1277 4.5979 2.4278 15.2259 2.3418 5.0459 7 -6.8477 4.3379 0.2078 16.1460 4.4600 3.8249 Mean -8.4877 4.4679 1.3178 15.6860 3.4009 4.4354 Std 2.3193 0.1839 1.5698 0.6506 1.4978 0.8634