Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 10 333.0778 262.7587 0.2585 -0.8295 1.7074 9 333.0762 262.7587 0.2591 -1.0577 1.2275 Mean 333.0770 262.7587 0.2588 -0.9436 1.4675 Std 0.0011 0.0000 0.0005 0.1614 0.3393 Error 0.00386 0.00167 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 10 -19.4377 5.9379 0.4478 8.7961 -5.5489 4.7568 9 -21.4275 5.0777 1.3378 7.5361 -7.1766 4.7548 Mean -20.4326 5.5078 0.8928 8.1661 -6.3628 4.7558 Std 1.4070 0.6082 0.6293 0.8909 1.1509 0.0014