Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 8 333.0828 262.7550 -1.9736 -2.1849 -3.6033 7 333.0864 262.7539 -1.9745 -2.2293 -3.9071 Mean 333.0846 262.7545 -1.9741 -2.2071 -3.7552 Std 0.0025 0.0008 0.0007 0.0314 0.2149 Error 0.00118 0.00108 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 8 -7.1472 -6.7226 6.1979 6.2556 -0.5544 1.1286 7 -1.3872 -7.0026 4.1879 7.4956 2.9825 0.0003 Mean -4.2672 -6.8626 5.1929 6.8756 1.2141 0.5644 Std 4.0730 0.1980 1.4213 0.8768 2.5010 0.7978