Magnet ID :     Calibration
Directory : S:\magdata\LCLS-II\Phase Shifter\Calibration\126Gcm_+Bx\Final Results\Stretched Wire
   
Date : 06-26-2018
Time : 13:16:05 - 14:21:00
Operator : VV
   
Project : DUMMY
Device Type : Phase Shifter
Run Number : 1
Data Type :
Run Comment : rewired; 126 Gauss*cm magnet (Bx positive)
   
gap I1Y I2Y I1X I2X
-
-12.1 0.9 (5)
-3.1 0.7 (5)
122.0 0.3 (5)
25.5 0.3 (5)

integral gap -02.00;+00.00 -01.00;+00.00 +00.00;+00.00 +01.00;+00.00 +02.00;+00.00
I1Y -
-14.7 3.4 (3)
-13.5 0.7 (3)
-12.9 0.4 (3)
-12.6 1.8 (3)
-13.1 0.1 (3)
I2Y -
-3.3 0.1 (2)
-3.6 0.2 (3)
-3.5 0.3 (3)
-3.5 0.1 (3)
-3.6 0.3 (3)
I1X -
123.6 2.6 (3)
112.3 14.2 (2)
124.7 2.4 (2)
115.7 11.6 (3)
114.3 17.1 (2)
I2X -
26.0 1.3 (2)
25.2 0.1 (3)
26.1 1.2 (2)
25.2 0.1 (3)
25.8 1.0 (3)

integral gap +00.00;-02.00 +00.00;-01.00 +00.00;+00.00 +00.00;+01.00 +00.00;+02.00
I1Y -
-11.4 0.8 (3)
-11.2 1.0 (3)
-11.3 1.1 (3)
-11.5 0.5 (3)
-11.2 1.0 (3)
I2Y -
-3.2 0.2 (3)
-3.0 0.1 (3)
-3.3 0.2 (3)
-3.0 0.1 (3)
-3.1 0.2 (3)
I1X -
121.4 0.8 (3)
119.9 0.3 (3)
120.7 1.0 (3)
121.3 2.3 (3)
120.0 0.4 (3)
I2X -
25.4 0.5 (3)
25.1 0.1 (3)
25.2 0.3 (3)
25.3 0.3 (3)
25.2 0.2 (3)