SLAC Magnetic Measurements Date: 08-27-2019 Time: 09:07:58 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4580 Serial Number: Run Number: 2 Measurement Device: 10wire Operator: sda Comment: BL vs current near 216.88 with trim at +/- 6 amps. Magnet stdz before measurements Standardization for MAIN: 3 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for MAIN (A): 216.82 216.82 216.82 216.82 216.82 300.00 Test Currents for TRIM (A): 0.00 -6.00 0.00 6.00 -6.00 0.00 Integrated Dipole Strength Distance the wire was to be moved = 0.009000 m Number of turns in the wire = 10 Number of measurements for averaging = 5 MAIN +/- sigma TRIM +/- sigma BL sigBL BL/I sigBL/I (A) (A) (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- ------------+---------- -------------+------------ -------------+------------- 216.7849 0.0003 0.0004 0.0001 0.243660 0.000034 0.001124 0.000000 216.7819 0.0002 -6.0044 0.0000 0.232869 0.000042 0.001074 0.000000 216.7788 0.0003 0.0004 0.0000 0.243675 0.000047 0.001124 0.000000 216.7760 0.0001 6.0035 0.0000 0.254849 0.000034 0.001176 0.000000 216.7743 0.0001 -6.0043 0.0000 0.233019 0.000040 0.001075 0.000000