SLAC Magnetic Measurements Date: 09-29-2022 Time: 16:33:06 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 68 Measurement Type: Long Coil Scans Operator: YL Comment: 2V; Bx field Center position: X0=0.000000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -1.398E-06 -19.974E-06 75.00000 75.00000 0 75.00000 0 75.00000 0 75.00005 0 1 -1.659E-06 -23.690E-06 75.00000 75.00005 0 75.00005 0 75.00010 0 75.00000 0 2 -1.349E-06 -19.272E-06 75.00000 75.00010 0 75.00000 0 75.00010 0 75.00005 0 3 -1.494E-06 -21.343E-06 75.00000 75.00010 0 75.00005 0 75.00010 0 75.00005 0 4 -1.365E-06 -19.497E-06 75.00000 75.00010 0 75.00000 0 75.00005 0 75.00010 0