SLAC Magnetic Measurements Date: 09-27-2022 Time: 17:16:04 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.000000, Y0=0.000000 Nominal Gap=20.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.439E-06 20.553E-06 20.00000 20.00070 0 20.00020 0 20.00075 0 20.00020 0 1 1.465E-06 20.920E-06 20.00000 20.00075 0 20.00020 0 20.00075 0 20.00020 0 2 1.536E-06 21.937E-06 20.00000 20.00075 0 20.00025 0 20.00075 0 20.00020 0 3 1.363E-06 19.472E-06 20.00000 20.00075 0 20.00020 0 20.00080 0 20.00025 0 4 1.489E-06 21.265E-06 20.00000 20.00080 0 20.00025 0 20.00085 0 20.00025 0