SLAC Magnetic Measurements Date: 09-28-2022 Time: 12:32:20 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 64 Measurement Type: Long Coil Scans Operator: YL Comment: 2H-TW; Skew Quad Center position: X0=-0.001000, Y0=0.000000 Nominal Gap=100.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -2.316E-06 -33.082E-06 100.00000 100.00005 0 100.00005 0 100.00005 0 100.00005 0 1 -2.442E-06 -34.873E-06 100.00000 100.00010 0 100.00005 0 100.00010 0 100.00005 0 2 -2.051E-06 -29.301E-06 100.00000 100.00010 0 100.00010 0 100.00015 0 100.00010 0 3 -2.151E-06 -30.725E-06 100.00000 100.00010 0 100.00010 0 100.00015 0 100.00010 0 4 -2.115E-06 -30.209E-06 100.00000 100.00015 0 100.00010 0 100.00015 0 100.00010 0