SLAC Magnetic Measurements Date: 09-28-2022 Time: 11:52:53 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 64 Measurement Type: Long Coil Scans Operator: YL Comment: 2H-TW; Skew Quad Center position: X0=-0.001000, Y0=0.000000 Nominal Gap=33.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -2.388E-06 -34.109E-06 33.00000 33.00030 0 33.00020 0 33.00025 0 33.00020 0 1 -2.341E-06 -33.442E-06 33.00000 33.00030 0 33.00020 0 33.00030 0 33.00015 0 2 -2.273E-06 -32.471E-06 33.00000 33.00030 0 33.00015 0 33.00030 0 33.00015 0 3 -2.500E-06 -35.706E-06 33.00000 33.00030 0 33.00015 0 33.00030 0 33.00015 0 4 -2.385E-06 -34.059E-06 33.00000 33.00030 0 33.00015 0 33.00030 0 33.00015 0