SLAC Magnetic Measurements Date: 10-03-2022 Time: 18:31:45 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 74 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=0.000000, Y0=0.000000 Nominal Gap=50.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -1.081E-06 -15.434E-06 50.00000 50.00005 0 50.00005 0 50.00010 0 50.00005 0 1 -0.929E-06 -13.272E-06 50.00000 50.00005 0 50.00005 0 50.00010 0 50.00005 0 2 -0.906E-06 -12.943E-06 50.00000 50.00010 0 50.00005 0 50.00010 0 50.00005 0 3 -0.786E-06 -11.220E-06 50.00000 50.00010 0 50.00005 0 50.00005 0 50.00010 0 4 -1.049E-06 -14.987E-06 50.00000 50.00005 0 50.00005 0 50.00005 0 50.00010 0