SLAC Magnetic Measurements Date: 10-03-2022 Time: 18:03:25 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 74 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=0.002000, Y0=0.000000 Nominal Gap=30.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -0.086E-06 -1.231E-06 30.00000 30.00040 0 30.00025 0 30.00045 0 30.00020 0 1 0.230E-06 3.284E-06 30.00000 30.00045 0 30.00020 0 30.00045 0 30.00020 0 2 0.154E-06 2.204E-06 30.00000 30.00045 0 30.00020 0 30.00040 0 30.00020 0 3 0.174E-06 2.486E-06 30.00000 30.00040 0 30.00020 0 30.00040 0 30.00025 0 4 0.172E-06 2.459E-06 30.00000 30.00040 0 30.00020 0 30.00040 0 30.00020 0