SLAC Magnetic Measurements Date: 10-04-2022 Time: 09:49:21 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 75 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4H Center position: X0=0.000000, Y0=0.000000 Nominal Gap=9.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -0.345E-06 -4.930E-06 9.00000 9.00035 0 9.00040 0 9.00040 0 9.00040 0 1 0.161E-06 2.299E-06 9.00000 9.00040 0 9.00040 0 9.00040 0 9.00040 0 2 -0.431E-06 -6.150E-06 9.00000 9.00040 0 9.00040 0 9.00040 0 9.00040 0 3 -0.349E-06 -4.988E-06 9.00000 9.00040 0 9.00040 0 9.00040 0 9.00040 0 4 -0.283E-06 -4.047E-06 9.00000 9.00040 0 9.00040 0 9.00045 0 9.00035 0