SLAC Magnetic Measurements Date: 11-17-2022 Time: 15:14:48 Project: FACET-II Magnet Type: Undulator Magnet Name: LHU-0003 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched wire Run Number: 7 Measurement Device: Stretched Wire Operator: YL Comment: 15:14:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:58 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:15:00 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:15:01 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:15:03 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 15:15:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:00 Integrated Voltage Measurement... 15:16:09 Voltage Offset Correction: v_off_ini = -290.846 uV, v_off_fin = -315.979 uV 15:16:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -218.626 uVs 15:16:09 Integrated Voltage Measurement... 15:16:18 Voltage Offset Correction: v_off_ini = -295.538 uV, v_off_fin = -284.149 uV 15:16:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 194.833 uVs 15:16:18 Integrated Voltage Measurement... 15:16:27 Voltage Offset Correction: v_off_ini = -278.917 uV, v_off_fin = -306.601 uV 15:16:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -215.368 uVs 15:16:27 Integrated Voltage Measurement... 15:16:36 Voltage Offset Correction: v_off_ini = -292.605 uV, v_off_fin = -275.898 uV 15:16:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 219.022 uVs 15:16:36 Integrated Voltage Measurement... 15:16:45 Voltage Offset Correction: v_off_ini = -292.275 uV, v_off_fin = -304.538 uV 15:16:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -220.094 uVs 15:16:45 Integrated Voltage Measurement... 15:16:54 Voltage Offset Correction: v_off_ini = -301.466 uV, v_off_fin = -294.663 uV 15:16:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 209.795 uVs 15:16:59 I1X Average and RMS of Measurements VT = -212.956 +- 4.498 uVs I1X = 42.591 +- 0.900 uTm 15:17:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:17:05 Integrated Voltage Measurement... 15:17:15 Voltage Offset Correction: v_off_ini = -296.398 uV, v_off_fin = -310.716 uV 15:17:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -9.850 uVs 15:17:15 Integrated Voltage Measurement... 15:17:24 Voltage Offset Correction: v_off_ini = -315.434 uV, v_off_fin = -308.080 uV 15:17:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 20.488 uVs 15:17:24 Integrated Voltage Measurement... 15:17:33 Voltage Offset Correction: v_off_ini = -311.612 uV, v_off_fin = -317.625 uV 15:17:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -28.676 uVs 15:17:33 Integrated Voltage Measurement... 15:17:42 Voltage Offset Correction: v_off_ini = -307.634 uV, v_off_fin = -321.317 uV 15:17:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 18.889 uVs 15:17:42 Integrated Voltage Measurement... 15:17:51 Voltage Offset Correction: v_off_ini = -319.687 uV, v_off_fin = -317.778 uV 15:17:51 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -8.902 uVs 15:17:51 Integrated Voltage Measurement... 15:18:00 Voltage Offset Correction: v_off_ini = -300.467 uV, v_off_fin = -293.730 uV 15:18:00 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 1.707 uVs 15:18:05 I1Y Average and RMS of Measurements VT = -14.752 +- 7.549 uVs I1Y = -2.951 +- 1.510 uTm 15:18:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:18:13 Integrated Voltage Measurement... 15:18:22 Voltage Offset Correction: v_off_ini = -316.592 uV, v_off_fin = -305.991 uV 15:18:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -170.291 uVs 15:18:22 Integrated Voltage Measurement... 15:18:32 Voltage Offset Correction: v_off_ini = -312.632 uV, v_off_fin = -313.218 uV 15:18:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.316 uVs 15:18:32 Integrated Voltage Measurement... 15:18:41 Voltage Offset Correction: v_off_ini = -319.875 uV, v_off_fin = -325.649 uV 15:18:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.565 uVs 15:18:41 Integrated Voltage Measurement... 15:18:51 Voltage Offset Correction: v_off_ini = -305.572 uV, v_off_fin = -315.188 uV 15:18:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.956 uVs 15:18:51 Integrated Voltage Measurement... 15:19:00 Voltage Offset Correction: v_off_ini = -293.847 uV, v_off_fin = -328.072 uV 15:19:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -181.020 uVs 15:19:00 Integrated Voltage Measurement... 15:19:10 Voltage Offset Correction: v_off_ini = -325.374 uV, v_off_fin = -324.597 uV 15:19:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 174.763 uVs 15:19:12 I2X Average and RMS of Measurements VT = -161.818 +- 12.918 uVs I2X = 13.269 +- 1.059 uTm^2 15:19:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:19:20 Integrated Voltage Measurement... 15:19:30 Voltage Offset Correction: v_off_ini = -324.065 uV, v_off_fin = -326.537 uV 15:19:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.803 uVs 15:19:30 Integrated Voltage Measurement... 15:19:39 Voltage Offset Correction: v_off_ini = -329.428 uV, v_off_fin = -319.253 uV 15:19:39 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = 243.674 uVs 15:19:39 Integrated Voltage Measurement... 15:19:49 Voltage Offset Correction: v_off_ini = -344.315 uV, v_off_fin = -346.651 uV 15:19:49 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -217.952 uVs 15:19:49 Integrated Voltage Measurement... 15:19:58 Voltage Offset Correction: v_off_ini = -325.475 uV, v_off_fin = -330.300 uV 15:19:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.809 uVs 15:19:58 Integrated Voltage Measurement... 15:20:08 Voltage Offset Correction: v_off_ini = -327.727 uV, v_off_fin = -333.632 uV 15:20:08 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -238.700 uVs 15:20:08 Integrated Voltage Measurement... 15:20:17 Voltage Offset Correction: v_off_ini = -329.951 uV, v_off_fin = -336.811 uV 15:20:17 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 230.777 uVs 15:20:20 I2Y Average and RMS of Measurements VT = -230.452 +- 7.895 uVs I2Y = -18.897 +- 0.648 uTm^2 15:20:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:51 Integrated Voltage Measurement... 15:50:00 Voltage Offset Correction: v_off_ini = -408.765 uV, v_off_fin = -414.220 uV 15:50:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -201.929 uVs 15:50:00 Integrated Voltage Measurement... 15:50:09 Voltage Offset Correction: v_off_ini = -393.186 uV, v_off_fin = -370.999 uV 15:50:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 222.778 uVs 15:50:09 Integrated Voltage Measurement... 15:50:18 Voltage Offset Correction: v_off_ini = -379.349 uV, v_off_fin = -409.178 uV 15:50:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -228.610 uVs 15:50:18 Integrated Voltage Measurement... 15:50:27 Voltage Offset Correction: v_off_ini = -407.716 uV, v_off_fin = -367.237 uV 15:50:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 252.249 uVs 15:50:27 Integrated Voltage Measurement... 15:50:36 Voltage Offset Correction: v_off_ini = -400.603 uV, v_off_fin = -404.860 uV 15:50:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -200.117 uVs 15:50:36 Integrated Voltage Measurement... 15:50:46 Voltage Offset Correction: v_off_ini = -368.995 uV, v_off_fin = -357.382 uV 15:50:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 237.999 uVs 15:50:50 I1X Average and RMS of Measurements VT = -223.947 +- 11.972 uVs I1X = 44.789 +- 2.394 uTm 15:50:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:57 Integrated Voltage Measurement... 15:51:06 Voltage Offset Correction: v_off_ini = -385.283 uV, v_off_fin = -386.821 uV 15:51:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 13.469 uVs 15:51:06 Integrated Voltage Measurement... 15:51:15 Voltage Offset Correction: v_off_ini = -392.856 uV, v_off_fin = -375.073 uV 15:51:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 19.590 uVs 15:51:15 Integrated Voltage Measurement... 15:51:24 Voltage Offset Correction: v_off_ini = -369.015 uV, v_off_fin = -366.488 uV 15:51:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 16.297 uVs 15:51:24 Integrated Voltage Measurement... 15:51:33 Voltage Offset Correction: v_off_ini = -373.468 uV, v_off_fin = -349.339 uV 15:51:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 4.453 uVs 15:51:33 Integrated Voltage Measurement... 15:51:42 Voltage Offset Correction: v_off_ini = -355.438 uV, v_off_fin = -365.485 uV 15:51:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.737 uVs 15:51:42 Integrated Voltage Measurement... 15:51:51 Voltage Offset Correction: v_off_ini = -368.436 uV, v_off_fin = -363.395 uV 15:51:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -23.106 uVs 15:51:55 I1Y Average and RMS of Measurements VT = 8.094 +- 10.112 uVs I1Y = 1.619 +- 2.022 uTm 15:52:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:52:03 Integrated Voltage Measurement... 15:52:13 Voltage Offset Correction: v_off_ini = -359.762 uV, v_off_fin = -355.735 uV 15:52:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -174.738 uVs 15:52:13 Integrated Voltage Measurement... 15:52:22 Voltage Offset Correction: v_off_ini = -357.844 uV, v_off_fin = -378.824 uV 15:52:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 212.629 uVs 15:52:22 Integrated Voltage Measurement... 15:52:32 Voltage Offset Correction: v_off_ini = -371.983 uV, v_off_fin = -371.128 uV 15:52:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -166.835 uVs 15:52:32 Integrated Voltage Measurement... 15:52:41 Voltage Offset Correction: v_off_ini = -371.839 uV, v_off_fin = -406.806 uV 15:52:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 245.731 uVs 15:52:41 Integrated Voltage Measurement... 15:52:51 Voltage Offset Correction: v_off_ini = -342.974 uV, v_off_fin = -364.415 uV 15:52:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -202.847 uVs 15:52:51 Integrated Voltage Measurement... 15:53:00 Voltage Offset Correction: v_off_ini = -366.764 uV, v_off_fin = -317.563 uV 15:53:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.778 uVs 15:53:03 I2X Average and RMS of Measurements VT = -193.426 +- 10.604 uVs I2X = 15.861 +- 0.870 uTm^2 15:53:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:53:11 Integrated Voltage Measurement... 15:53:20 Voltage Offset Correction: v_off_ini = -352.505 uV, v_off_fin = -356.658 uV 15:53:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.653 uVs 15:53:20 Integrated Voltage Measurement... 15:53:30 Voltage Offset Correction: v_off_ini = -355.222 uV, v_off_fin = -353.664 uV 15:53:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.204 uVs 15:53:30 Integrated Voltage Measurement... 15:53:39 Voltage Offset Correction: v_off_ini = -363.996 uV, v_off_fin = -372.898 uV 15:53:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.504 uVs 15:53:39 Integrated Voltage Measurement... 15:53:49 Voltage Offset Correction: v_off_ini = -357.244 uV, v_off_fin = -348.178 uV 15:53:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.138 uVs 15:53:49 Integrated Voltage Measurement... 15:53:58 Voltage Offset Correction: v_off_ini = -359.352 uV, v_off_fin = -350.032 uV 15:53:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -176.341 uVs 15:53:58 Integrated Voltage Measurement... 15:54:08 Voltage Offset Correction: v_off_ini = -341.405 uV, v_off_fin = -345.841 uV 15:54:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 147.310 uVs 15:54:10 I2Y Average and RMS of Measurements VT = -166.858 +- 6.696 uVs I2Y = -13.682 +- 0.549 uTm^2 15:54:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:34 Integrated Voltage Measurement... 15:56:43 Voltage Offset Correction: v_off_ini = -375.124 uV, v_off_fin = -376.483 uV 15:56:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -180.459 uVs 15:56:43 Integrated Voltage Measurement... 15:56:52 Voltage Offset Correction: v_off_ini = -370.787 uV, v_off_fin = -350.500 uV 15:56:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 224.664 uVs 15:56:52 Integrated Voltage Measurement... 15:57:01 Voltage Offset Correction: v_off_ini = -362.822 uV, v_off_fin = -369.306 uV 15:57:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -242.773 uVs 15:57:01 Integrated Voltage Measurement... 15:57:10 Voltage Offset Correction: v_off_ini = -367.879 uV, v_off_fin = -350.340 uV 15:57:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 216.574 uVs 15:57:10 Integrated Voltage Measurement... 15:57:19 Voltage Offset Correction: v_off_ini = -364.348 uV, v_off_fin = -371.488 uV 15:57:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -205.369 uVs 15:57:20 Integrated Voltage Measurement... 15:57:29 Voltage Offset Correction: v_off_ini = -355.390 uV, v_off_fin = -338.332 uV 15:57:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 207.039 uVs 15:57:33 I1X Average and RMS of Measurements VT = -212.813 +- 12.014 uVs I1X = 42.563 +- 2.403 uTm 15:57:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:40 Integrated Voltage Measurement... 15:57:49 Voltage Offset Correction: v_off_ini = -349.057 uV, v_off_fin = -354.675 uV 15:57:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -17.368 uVs 15:57:49 Integrated Voltage Measurement... 15:57:58 Voltage Offset Correction: v_off_ini = -346.552 uV, v_off_fin = -349.617 uV 15:57:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 22.579 uVs 15:57:58 Integrated Voltage Measurement... 15:58:07 Voltage Offset Correction: v_off_ini = -354.942 uV, v_off_fin = -357.822 uV 15:58:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -27.381 uVs 15:58:07 Integrated Voltage Measurement... 15:58:16 Voltage Offset Correction: v_off_ini = -364.905 uV, v_off_fin = -354.461 uV 15:58:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 42.519 uVs 15:58:16 Integrated Voltage Measurement... 15:58:25 Voltage Offset Correction: v_off_ini = -349.763 uV, v_off_fin = -361.208 uV 15:58:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -19.593 uVs 15:58:26 Integrated Voltage Measurement... 15:58:35 Voltage Offset Correction: v_off_ini = -356.400 uV, v_off_fin = -350.915 uV 15:58:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 56.662 uVs 15:58:39 I1Y Average and RMS of Measurements VT = -31.017 +- 7.916 uVs I1Y = -6.203 +- 1.583 uTm 15:58:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:47 Integrated Voltage Measurement... 15:58:56 Voltage Offset Correction: v_off_ini = -357.437 uV, v_off_fin = -353.399 uV 15:58:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.062 uVs 15:58:56 Integrated Voltage Measurement... 15:59:06 Voltage Offset Correction: v_off_ini = -351.090 uV, v_off_fin = -341.627 uV 15:59:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.902 uVs 15:59:06 Integrated Voltage Measurement... 15:59:15 Voltage Offset Correction: v_off_ini = -334.711 uV, v_off_fin = -348.736 uV 15:59:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -186.429 uVs 15:59:15 Integrated Voltage Measurement... 15:59:25 Voltage Offset Correction: v_off_ini = -342.454 uV, v_off_fin = -334.432 uV 15:59:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 161.953 uVs 15:59:25 Integrated Voltage Measurement... 15:59:34 Voltage Offset Correction: v_off_ini = -331.199 uV, v_off_fin = -330.336 uV 15:59:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -167.472 uVs 15:59:34 Integrated Voltage Measurement... 15:59:44 Voltage Offset Correction: v_off_ini = -331.480 uV, v_off_fin = -333.228 uV 15:59:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.823 uVs 15:59:46 I2X Average and RMS of Measurements VT = -157.774 +- 13.157 uVs I2X = 12.937 +- 1.079 uTm^2 15:59:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:54 Integrated Voltage Measurement... 16:00:04 Voltage Offset Correction: v_off_ini = -333.377 uV, v_off_fin = -349.392 uV 16:00:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.473 uVs 16:00:04 Integrated Voltage Measurement... 16:00:13 Voltage Offset Correction: v_off_ini = -333.033 uV, v_off_fin = -334.376 uV 16:00:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.193 uVs 16:00:13 Integrated Voltage Measurement... 16:00:23 Voltage Offset Correction: v_off_ini = -326.633 uV, v_off_fin = -334.629 uV 16:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.038 uVs 16:00:23 Integrated Voltage Measurement... 16:00:32 Voltage Offset Correction: v_off_ini = -337.517 uV, v_off_fin = -335.903 uV 16:00:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.079 uVs 16:00:32 Integrated Voltage Measurement... 16:00:42 Voltage Offset Correction: v_off_ini = -341.923 uV, v_off_fin = -336.814 uV 16:00:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.387 uVs 16:00:42 Integrated Voltage Measurement... 16:00:51 Voltage Offset Correction: v_off_ini = -338.346 uV, v_off_fin = -338.750 uV 16:00:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.728 uVs 16:00:54 I2Y Average and RMS of Measurements VT = -241.816 +- 8.084 uVs I2Y = -19.829 +- 0.663 uTm^2 16:00:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:58 Integrated Voltage Measurement... 16:03:07 Voltage Offset Correction: v_off_ini = -333.829 uV, v_off_fin = -356.381 uV 16:03:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -206.743 uVs 16:03:07 Integrated Voltage Measurement... 16:03:16 Voltage Offset Correction: v_off_ini = -323.794 uV, v_off_fin = -332.614 uV 16:03:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 198.104 uVs 16:03:16 Integrated Voltage Measurement... 16:03:25 Voltage Offset Correction: v_off_ini = -334.651 uV, v_off_fin = -363.965 uV 16:03:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -202.600 uVs 16:03:25 Integrated Voltage Measurement... 16:03:34 Voltage Offset Correction: v_off_ini = -338.994 uV, v_off_fin = -339.060 uV 16:03:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 197.422 uVs 16:03:34 Integrated Voltage Measurement... 16:03:43 Voltage Offset Correction: v_off_ini = -343.181 uV, v_off_fin = -361.588 uV 16:03:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -199.683 uVs 16:03:43 Integrated Voltage Measurement... 16:03:52 Voltage Offset Correction: v_off_ini = -350.995 uV, v_off_fin = -312.160 uV 16:03:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 220.620 uVs 16:03:57 I1X Average and RMS of Measurements VT = -204.195 +- 4.325 uVs I1X = 40.839 +- 0.865 uTm 16:03:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:03 Integrated Voltage Measurement... 16:04:13 Voltage Offset Correction: v_off_ini = -357.039 uV, v_off_fin = -352.828 uV 16:04:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -30.474 uVs 16:04:13 Integrated Voltage Measurement... 16:04:22 Voltage Offset Correction: v_off_ini = -338.917 uV, v_off_fin = -345.625 uV 16:04:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 13.033 uVs 16:04:22 Integrated Voltage Measurement... 16:04:31 Voltage Offset Correction: v_off_ini = -352.125 uV, v_off_fin = -343.301 uV 16:04:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -12.507 uVs 16:04:31 Integrated Voltage Measurement... 16:04:40 Voltage Offset Correction: v_off_ini = -359.358 uV, v_off_fin = -343.040 uV 16:04:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 51.297 uVs 16:04:40 Integrated Voltage Measurement... 16:04:49 Voltage Offset Correction: v_off_ini = -346.882 uV, v_off_fin = -342.416 uV 16:04:49 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -30.149 uVs 16:04:49 Integrated Voltage Measurement... 16:04:58 Voltage Offset Correction: v_off_ini = -325.832 uV, v_off_fin = -331.910 uV 16:04:58 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = 5.338 uVs 16:05:03 I1Y Average and RMS of Measurements VT = -23.800 +- 5.959 uVs I1Y = -4.760 +- 1.192 uTm 16:05:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:11 Integrated Voltage Measurement... 16:05:20 Voltage Offset Correction: v_off_ini = -328.285 uV, v_off_fin = -324.834 uV 16:05:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -162.945 uVs 16:05:20 Integrated Voltage Measurement... 16:05:30 Voltage Offset Correction: v_off_ini = -327.958 uV, v_off_fin = -313.827 uV 16:05:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 160.691 uVs 16:05:30 Integrated Voltage Measurement... 16:05:39 Voltage Offset Correction: v_off_ini = -314.904 uV, v_off_fin = -314.580 uV 16:05:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.216 uVs 16:05:39 Integrated Voltage Measurement... 16:05:49 Voltage Offset Correction: v_off_ini = -316.800 uV, v_off_fin = -307.946 uV 16:05:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.359 uVs 16:05:49 Integrated Voltage Measurement... 16:05:58 Voltage Offset Correction: v_off_ini = -308.837 uV, v_off_fin = -309.384 uV 16:05:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.818 uVs 16:05:58 Integrated Voltage Measurement... 16:06:08 Voltage Offset Correction: v_off_ini = -302.037 uV, v_off_fin = -293.393 uV 16:06:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 153.396 uVs 16:06:10 I2X Average and RMS of Measurements VT = -157.571 +- 3.016 uVs I2X = 12.921 +- 0.247 uTm^2 16:06:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:18 Integrated Voltage Measurement... 16:06:28 Voltage Offset Correction: v_off_ini = -298.529 uV, v_off_fin = -303.424 uV 16:06:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.035 uVs 16:06:28 Integrated Voltage Measurement... 16:06:37 Voltage Offset Correction: v_off_ini = -294.023 uV, v_off_fin = -300.961 uV 16:06:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.311 uVs 16:06:37 Integrated Voltage Measurement... 16:06:47 Voltage Offset Correction: v_off_ini = -296.494 uV, v_off_fin = -311.095 uV 16:06:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.800 uVs 16:06:47 Integrated Voltage Measurement... 16:06:56 Voltage Offset Correction: v_off_ini = -328.732 uV, v_off_fin = -318.495 uV 16:06:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.418 uVs 16:06:56 Integrated Voltage Measurement... 16:07:06 Voltage Offset Correction: v_off_ini = -312.958 uV, v_off_fin = -334.706 uV 16:07:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.548 uVs 16:07:06 Integrated Voltage Measurement... 16:07:15 Voltage Offset Correction: v_off_ini = -316.532 uV, v_off_fin = -310.733 uV 16:07:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.848 uVs 16:07:18 I2Y Average and RMS of Measurements VT = -262.493 +- 8.384 uVs I2Y = -21.524 +- 0.687 uTm^2 16:10:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = -557.112 uV, v_off_fin = -572.258 uV 16:30:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.964 uVs 16:30:44 Integrated Voltage Measurement... 16:30:53 Voltage Offset Correction: v_off_ini = -562.717 uV, v_off_fin = -552.446 uV 16:30:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.268 uVs 16:30:53 Integrated Voltage Measurement... 16:31:02 Voltage Offset Correction: v_off_ini = -546.761 uV, v_off_fin = -560.425 uV 16:31:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.434 uVs 16:31:03 Integrated Voltage Measurement... 16:31:12 Voltage Offset Correction: v_off_ini = -550.354 uV, v_off_fin = -543.780 uV 16:31:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.837 uVs 16:31:12 Integrated Voltage Measurement... 16:31:21 Voltage Offset Correction: v_off_ini = -542.166 uV, v_off_fin = -553.523 uV 16:31:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.363 uVs 16:31:21 Integrated Voltage Measurement... 16:31:30 Voltage Offset Correction: v_off_ini = -542.347 uV, v_off_fin = -531.607 uV 16:31:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.840 uVs 16:31:34 I1X Average and RMS of Measurements VT = -35.451 +- 5.197 uVs I1X = 7.090 +- 1.039 uTm 16:31:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:41 Integrated Voltage Measurement... 16:31:50 Voltage Offset Correction: v_off_ini = -538.702 uV, v_off_fin = -514.880 uV 16:31:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 239.081 uVs 16:31:50 Integrated Voltage Measurement... 16:31:59 Voltage Offset Correction: v_off_ini = -525.093 uV, v_off_fin = -543.931 uV 16:31:59 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = -272.518 uVs 16:31:59 Integrated Voltage Measurement... 16:32:08 Voltage Offset Correction: v_off_ini = -529.572 uV, v_off_fin = -514.857 uV 16:32:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 269.809 uVs 16:32:08 Integrated Voltage Measurement... 16:32:18 Voltage Offset Correction: v_off_ini = -523.543 uV, v_off_fin = -546.614 uV 16:32:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -250.982 uVs 16:32:18 Integrated Voltage Measurement... 16:32:27 Voltage Offset Correction: v_off_ini = -507.888 uV, v_off_fin = -494.905 uV 16:32:27 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = 237.865 uVs 16:32:27 Integrated Voltage Measurement... 16:32:36 Voltage Offset Correction: v_off_ini = -502.506 uV, v_off_fin = -529.438 uV 16:32:36 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5001 mm dXY = -0.5001 mm VT = -247.113 uVs 16:32:40 I1Y Average and RMS of Measurements VT = 252.895 +- 7.593 uVs I1Y = 50.573 +- 1.523 uTm 16:32:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:32:48 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = -501.875 uV, v_off_fin = -509.215 uV 16:32:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 139.234 uVs 16:32:58 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = -511.718 uV, v_off_fin = -508.823 uV 16:33:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -146.224 uVs 16:33:07 Integrated Voltage Measurement... 16:33:17 Voltage Offset Correction: v_off_ini = -520.736 uV, v_off_fin = -515.211 uV 16:33:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 138.577 uVs 16:33:17 Integrated Voltage Measurement... 16:33:26 Voltage Offset Correction: v_off_ini = -508.343 uV, v_off_fin = -513.164 uV 16:33:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -148.939 uVs 16:33:26 Integrated Voltage Measurement... 16:33:36 Voltage Offset Correction: v_off_ini = -501.780 uV, v_off_fin = -503.131 uV 16:33:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 116.951 uVs 16:33:36 Integrated Voltage Measurement... 16:33:45 Voltage Offset Correction: v_off_ini = -499.692 uV, v_off_fin = -504.751 uV 16:33:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.569 uVs 16:33:48 I2X Average and RMS of Measurements VT = 142.249 +- 1.468 uVs I2X = -11.664 +- 0.120 uTm^2 16:33:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:56 Integrated Voltage Measurement... 16:34:05 Voltage Offset Correction: v_off_ini = -489.059 uV, v_off_fin = -510.336 uV 16:34:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 211.475 uVs 16:34:05 Integrated Voltage Measurement... 16:34:15 Voltage Offset Correction: v_off_ini = -490.545 uV, v_off_fin = -493.892 uV 16:34:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -243.945 uVs 16:34:15 Integrated Voltage Measurement... 16:34:24 Voltage Offset Correction: v_off_ini = -508.323 uV, v_off_fin = -511.776 uV 16:34:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 239.270 uVs 16:34:24 Integrated Voltage Measurement... 16:34:34 Voltage Offset Correction: v_off_ini = -508.270 uV, v_off_fin = -512.287 uV 16:34:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -197.767 uVs 16:34:34 Integrated Voltage Measurement... 16:34:43 Voltage Offset Correction: v_off_ini = -505.888 uV, v_off_fin = -512.873 uV 16:34:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 214.766 uVs 16:34:43 Integrated Voltage Measurement... 16:34:53 Voltage Offset Correction: v_off_ini = -488.296 uV, v_off_fin = -498.763 uV 16:34:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -255.946 uVs 16:34:55 I2Y Average and RMS of Measurements VT = 227.195 +- 6.884 uVs I2Y = 18.630 +- 0.564 uTm^2 16:34:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm