SLAC Magnetic Measurements Date: 11-17-2022 Time: 15:14:48 Project: FACET-II Magnet Type: Undulator Magnet Name: LHU-0003 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched wire Run Number: 7 Measurement Device: Stretched Wire Operator: YL Comment: Parameters: Measurement Type = I12XY VS X VS GAP I1X dy = 0.5000 mm I1Y dx = 0.5000 mm I2X dy = 1.0000 mm I2Y dx = 1.0000 mm Wire # Turns = 1 Preamplifier Gain = 10000.00 Background Field Integrals: I1X = 10000.0 (uTm) I1Y = -29000.0 (uTm) I2X = 5000.0 (uTm2) I2Y = -13000.0 (uTm2) Subtracted from results Field Integrals: Gap (mm) X0 (mm) Y0 (mm) I1x (uTm) I1y (uTm) I2x (uTm^2) I2y (uTm^2) ---------- ---------- ---------- ---------------------- ---------------------- ---------------------- ---------------------- 40.000 0.000 0.000 32.591+- 0.900 26.049+- 1.510 8.269+- 1.059 -5.897+- 0.648 40.000 0.000 0.000 34.789+- 2.394 30.619+- 2.022 10.861+- 0.870 -0.682+- 0.549 40.000 0.000 0.000 32.563+- 2.403 22.797+- 1.583 7.937+- 1.079 -6.829+- 0.663 40.000 0.000 0.000 30.839+- 0.865 24.240+- 1.192 7.921+- 0.247 -8.524+- 0.687 40.000 0.000 0.000 -2.910+- 1.039 79.573+- 1.523 -16.664+- 0.120 31.630+- 0.564