SLAC Magnetic Measurements Date: 11-17-2022 Time: 11:05:25 Project: FACET-II Magnet Type: Undulator Magnet Name: LHU-0003 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched wire Run Number: 5 Measurement Device: Stretched Wire Operator: YL Comment: 11:05:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:05:35 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:05:36 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:05:38 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:05:39 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:06:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:06:24 Integrated Voltage Measurement... 11:06:33 Voltage Offset Correction: v_off_ini = 108.089 uV, v_off_fin = 79.545 uV 11:06:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -165.812 uVs 11:06:33 Integrated Voltage Measurement... 11:06:42 Voltage Offset Correction: v_off_ini = 75.979 uV, v_off_fin = 90.558 uV 11:06:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.423 uVs 11:06:42 Integrated Voltage Measurement... 11:06:51 Voltage Offset Correction: v_off_ini = 86.964 uV, v_off_fin = 79.807 uV 11:06:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.587 uVs 11:06:51 Integrated Voltage Measurement... 11:07:00 Voltage Offset Correction: v_off_ini = 80.685 uV, v_off_fin = 90.167 uV 11:07:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.351 uVs 11:07:00 Integrated Voltage Measurement... 11:07:09 Voltage Offset Correction: v_off_ini = 91.779 uV, v_off_fin = 65.798 uV 11:07:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -166.867 uVs 11:07:09 Integrated Voltage Measurement... 11:07:19 Voltage Offset Correction: v_off_ini = 84.646 uV, v_off_fin = 96.334 uV 11:07:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.834 uVs 11:07:23 I1X Average and RMS of Measurements VT = -161.479 +- 2.618 uVs I1X = 32.296 +- 0.524 uTm 11:07:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:07:30 Integrated Voltage Measurement... 11:07:39 Voltage Offset Correction: v_off_ini = 92.166 uV, v_off_fin = 77.869 uV 11:07:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -70.848 uVs 11:07:39 Integrated Voltage Measurement... 11:07:48 Voltage Offset Correction: v_off_ini = 79.584 uV, v_off_fin = 94.793 uV 11:07:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 84.977 uVs 11:07:48 Integrated Voltage Measurement... 11:07:57 Voltage Offset Correction: v_off_ini = 93.580 uV, v_off_fin = 92.186 uV 11:07:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -58.379 uVs 11:07:57 Integrated Voltage Measurement... 11:08:06 Voltage Offset Correction: v_off_ini = 102.735 uV, v_off_fin = 101.533 uV 11:08:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 70.624 uVs 11:08:06 Integrated Voltage Measurement... 11:08:15 Voltage Offset Correction: v_off_ini = 94.852 uV, v_off_fin = 87.874 uV 11:08:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -73.425 uVs 11:08:15 Integrated Voltage Measurement... 11:08:24 Voltage Offset Correction: v_off_ini = 99.184 uV, v_off_fin = 102.951 uV 11:08:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 48.516 uVs 11:08:29 I1Y Average and RMS of Measurements VT = -67.795 +- 7.298 uVs I1Y = -13.559 +- 1.460 uTm 11:08:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:08:37 Integrated Voltage Measurement... 11:08:46 Voltage Offset Correction: v_off_ini = 98.155 uV, v_off_fin = 96.650 uV 11:08:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -187.907 uVs 11:08:46 Integrated Voltage Measurement... 11:08:56 Voltage Offset Correction: v_off_ini = 96.727 uV, v_off_fin = 100.171 uV 11:08:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 187.402 uVs 11:08:56 Integrated Voltage Measurement... 11:09:05 Voltage Offset Correction: v_off_ini = 97.505 uV, v_off_fin = 104.936 uV 11:09:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.799 uVs 11:09:05 Integrated Voltage Measurement... 11:09:15 Voltage Offset Correction: v_off_ini = 102.912 uV, v_off_fin = 104.907 uV 11:09:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 193.011 uVs 11:09:15 Integrated Voltage Measurement... 11:09:24 Voltage Offset Correction: v_off_ini = 92.679 uV, v_off_fin = 92.128 uV 11:09:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -161.648 uVs 11:09:24 Integrated Voltage Measurement... 11:09:34 Voltage Offset Correction: v_off_ini = 94.620 uV, v_off_fin = 97.929 uV 11:09:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 181.760 uVs 11:09:36 I2X Average and RMS of Measurements VT = -175.088 +- 9.196 uVs I2X = 14.357 +- 0.754 uTm^2 11:09:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:09:44 Integrated Voltage Measurement... 11:09:54 Voltage Offset Correction: v_off_ini = 88.371 uV, v_off_fin = 88.319 uV 11:09:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.831 uVs 11:09:54 Integrated Voltage Measurement... 11:10:03 Voltage Offset Correction: v_off_ini = 94.182 uV, v_off_fin = 89.963 uV 11:10:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.436 uVs 11:10:03 Integrated Voltage Measurement... 11:10:13 Voltage Offset Correction: v_off_ini = 94.928 uV, v_off_fin = 86.235 uV 11:10:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.554 uVs 11:10:13 Integrated Voltage Measurement... 11:10:22 Voltage Offset Correction: v_off_ini = 82.965 uV, v_off_fin = 87.142 uV 11:10:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.543 uVs 11:10:22 Integrated Voltage Measurement... 11:10:32 Voltage Offset Correction: v_off_ini = 80.393 uV, v_off_fin = 82.957 uV 11:10:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.825 uVs 11:10:32 Integrated Voltage Measurement... 11:10:41 Voltage Offset Correction: v_off_ini = 85.018 uV, v_off_fin = 80.297 uV 11:10:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.396 uVs 11:10:44 I2Y Average and RMS of Measurements VT = -280.431 +- 7.079 uVs I2Y = -22.995 +- 0.580 uTm^2 11:10:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm