SLAC Magnetic Measurements Date: 07-02-2025 Time: 13:42:03 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16352 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 5 Measurement Device: Operator: YL Comment: On-Axis 13:42:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:42:13 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:42:15 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:42:16 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:42:18 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:44:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:01 Integrated Voltage Measurement... 13:45:10 Voltage Offset Correction: v_off_ini = 157.166 uV, v_off_fin = 146.290 uV 13:45:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.634 uVs 13:45:10 Integrated Voltage Measurement... 13:45:19 Voltage Offset Correction: v_off_ini = 149.105 uV, v_off_fin = 134.514 uV 13:45:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.371 uVs 13:45:19 Integrated Voltage Measurement... 13:45:28 Voltage Offset Correction: v_off_ini = 141.450 uV, v_off_fin = 137.893 uV 13:45:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -69.164 uVs 13:45:28 Integrated Voltage Measurement... 13:45:37 Voltage Offset Correction: v_off_ini = 138.342 uV, v_off_fin = 135.064 uV 13:45:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 84.228 uVs 13:45:37 Integrated Voltage Measurement... 13:45:46 Voltage Offset Correction: v_off_ini = 135.585 uV, v_off_fin = 133.683 uV 13:45:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.410 uVs 13:45:46 Integrated Voltage Measurement... 13:45:55 Voltage Offset Correction: v_off_ini = 144.896 uV, v_off_fin = 144.444 uV 13:45:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.821 uVs 13:45:59 I1X Average and RMS of Measurements VT = -70.271 +- 14.174 uVs I1X = 14.055 +- 2.835 uTm 13:46:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:06 Integrated Voltage Measurement... 13:46:15 Voltage Offset Correction: v_off_ini = 132.949 uV, v_off_fin = 130.538 uV 13:46:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.113 uVs 13:46:15 Integrated Voltage Measurement... 13:46:24 Voltage Offset Correction: v_off_ini = 145.703 uV, v_off_fin = 156.967 uV 13:46:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.202 uVs 13:46:24 Integrated Voltage Measurement... 13:46:33 Voltage Offset Correction: v_off_ini = 146.673 uV, v_off_fin = 139.286 uV 13:46:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.804 uVs 13:46:33 Integrated Voltage Measurement... 13:46:42 Voltage Offset Correction: v_off_ini = 149.874 uV, v_off_fin = 160.879 uV 13:46:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.783 uVs 13:46:42 Integrated Voltage Measurement... 13:46:51 Voltage Offset Correction: v_off_ini = 150.702 uV, v_off_fin = 138.168 uV 13:46:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.536 uVs 13:46:51 Integrated Voltage Measurement... 13:47:00 Voltage Offset Correction: v_off_ini = 132.460 uV, v_off_fin = 154.921 uV 13:47:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.842 uVs 13:47:04 I1Y Average and RMS of Measurements VT = -216.047 +- 5.943 uVs I1Y = -43.209 +- 1.189 uTm 13:47:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:12 Integrated Voltage Measurement... 13:47:21 Voltage Offset Correction: v_off_ini = 163.321 uV, v_off_fin = 149.052 uV 13:47:21 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -57.315 uVs 13:47:21 Integrated Voltage Measurement... 13:47:30 Voltage Offset Correction: v_off_ini = 149.930 uV, v_off_fin = 152.914 uV 13:47:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.844 uVs 13:47:30 Integrated Voltage Measurement... 13:47:39 Voltage Offset Correction: v_off_ini = 129.826 uV, v_off_fin = 129.466 uV 13:47:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.503 uVs 13:47:39 Integrated Voltage Measurement... 13:47:48 Voltage Offset Correction: v_off_ini = 137.036 uV, v_off_fin = 152.823 uV 13:47:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.423 uVs 13:47:48 Integrated Voltage Measurement... 13:47:57 Voltage Offset Correction: v_off_ini = 152.307 uV, v_off_fin = 136.218 uV 13:47:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.700 uVs 13:47:57 Integrated Voltage Measurement... 13:48:06 Voltage Offset Correction: v_off_ini = 144.350 uV, v_off_fin = 155.992 uV 13:48:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.777 uVs 13:48:09 I2X Average and RMS of Measurements VT = -48.594 +- 5.691 uVs I2X = 4.470 +- 0.523 uTm^2 13:48:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:16 Integrated Voltage Measurement... 13:48:25 Voltage Offset Correction: v_off_ini = 140.304 uV, v_off_fin = 150.330 uV 13:48:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.988 uVs 13:48:26 Integrated Voltage Measurement... 13:48:35 Voltage Offset Correction: v_off_ini = 145.757 uV, v_off_fin = 140.838 uV 13:48:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.706 uVs 13:48:35 Integrated Voltage Measurement... 13:48:44 Voltage Offset Correction: v_off_ini = 137.341 uV, v_off_fin = 124.912 uV 13:48:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.226 uVs 13:48:44 Integrated Voltage Measurement... 13:48:53 Voltage Offset Correction: v_off_ini = 126.615 uV, v_off_fin = 139.072 uV 13:48:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.198 uVs 13:48:53 Integrated Voltage Measurement... 13:49:02 Voltage Offset Correction: v_off_ini = 141.421 uV, v_off_fin = 137.104 uV 13:49:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.395 uVs 13:49:02 Integrated Voltage Measurement... 13:49:11 Voltage Offset Correction: v_off_ini = 131.850 uV, v_off_fin = 130.003 uV 13:49:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.932 uVs 13:49:13 I2Y Average and RMS of Measurements VT = -217.908 +- 9.786 uVs I2Y = -20.047 +- 0.900 uTm^2 13:49:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:49:28 Integrated Voltage Measurement... 13:49:37 Voltage Offset Correction: v_off_ini = 127.120 uV, v_off_fin = 136.218 uV 13:49:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.679 uVs 13:49:37 Integrated Voltage Measurement... 13:49:46 Voltage Offset Correction: v_off_ini = 126.536 uV, v_off_fin = 135.027 uV 13:49:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.962 uVs 13:49:46 Integrated Voltage Measurement... 13:49:55 Voltage Offset Correction: v_off_ini = 130.969 uV, v_off_fin = 123.369 uV 13:49:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.996 uVs 13:49:55 Integrated Voltage Measurement... 13:50:04 Voltage Offset Correction: v_off_ini = 126.892 uV, v_off_fin = 134.039 uV 13:50:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 73.634 uVs 13:50:04 Integrated Voltage Measurement... 13:50:13 Voltage Offset Correction: v_off_ini = 136.218 uV, v_off_fin = 132.212 uV 13:50:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.041 uVs 13:50:13 Integrated Voltage Measurement... 13:50:22 Voltage Offset Correction: v_off_ini = 135.970 uV, v_off_fin = 142.496 uV 13:50:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.742 uVs 13:50:26 I1X Average and RMS of Measurements VT = -75.342 +- 5.342 uVs I1X = 15.069 +- 1.068 uTm 13:50:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:50:33 Integrated Voltage Measurement... 13:50:42 Voltage Offset Correction: v_off_ini = 131.238 uV, v_off_fin = 130.632 uV 13:50:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -218.815 uVs 13:50:42 Integrated Voltage Measurement... 13:50:51 Voltage Offset Correction: v_off_ini = 140.284 uV, v_off_fin = 150.297 uV 13:50:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.227 uVs 13:50:51 Integrated Voltage Measurement... 13:51:00 Voltage Offset Correction: v_off_ini = 142.956 uV, v_off_fin = 133.960 uV 13:51:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.359 uVs 13:51:00 Integrated Voltage Measurement... 13:51:09 Voltage Offset Correction: v_off_ini = 143.379 uV, v_off_fin = 150.055 uV 13:51:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.215 uVs 13:51:09 Integrated Voltage Measurement... 13:51:18 Voltage Offset Correction: v_off_ini = 141.243 uV, v_off_fin = 128.829 uV 13:51:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.721 uVs 13:51:18 Integrated Voltage Measurement... 13:51:27 Voltage Offset Correction: v_off_ini = 131.645 uV, v_off_fin = 138.173 uV 13:51:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.786 uVs 13:51:31 I1Y Average and RMS of Measurements VT = -220.020 +- 1.061 uVs I1Y = -44.005 +- 0.213 uTm 13:51:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:39 Integrated Voltage Measurement... 13:51:48 Voltage Offset Correction: v_off_ini = 133.397 uV, v_off_fin = 126.471 uV 13:51:48 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -51.979 uVs 13:51:48 Integrated Voltage Measurement... 13:51:57 Voltage Offset Correction: v_off_ini = 130.945 uV, v_off_fin = 147.142 uV 13:51:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.462 uVs 13:51:57 Integrated Voltage Measurement... 13:52:06 Voltage Offset Correction: v_off_ini = 127.352 uV, v_off_fin = 128.112 uV 13:52:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.975 uVs 13:52:06 Integrated Voltage Measurement... 13:52:15 Voltage Offset Correction: v_off_ini = 138.005 uV, v_off_fin = 151.996 uV 13:52:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 38.688 uVs 13:52:15 Integrated Voltage Measurement... 13:52:24 Voltage Offset Correction: v_off_ini = 136.003 uV, v_off_fin = 127.580 uV 13:52:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.292 uVs 13:52:24 Integrated Voltage Measurement... 13:52:33 Voltage Offset Correction: v_off_ini = 128.419 uV, v_off_fin = 140.411 uV 13:52:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.804 uVs 13:52:36 I2X Average and RMS of Measurements VT = -47.033 +- 1.938 uVs I2X = 4.327 +- 0.178 uTm^2 13:52:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:44 Integrated Voltage Measurement... 13:52:53 Voltage Offset Correction: v_off_ini = 149.971 uV, v_off_fin = 146.090 uV 13:52:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.154 uVs 13:52:53 Integrated Voltage Measurement... 13:53:02 Voltage Offset Correction: v_off_ini = 142.741 uV, v_off_fin = 145.894 uV 13:53:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.561 uVs 13:53:02 Integrated Voltage Measurement... 13:53:11 Voltage Offset Correction: v_off_ini = 139.953 uV, v_off_fin = 149.870 uV 13:53:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.931 uVs 13:53:11 Integrated Voltage Measurement... 13:53:20 Voltage Offset Correction: v_off_ini = 135.792 uV, v_off_fin = 137.410 uV 13:53:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.506 uVs 13:53:20 Integrated Voltage Measurement... 13:53:29 Voltage Offset Correction: v_off_ini = 146.032 uV, v_off_fin = 143.263 uV 13:53:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.208 uVs 13:53:29 Integrated Voltage Measurement... 13:53:38 Voltage Offset Correction: v_off_ini = 131.408 uV, v_off_fin = 137.183 uV 13:53:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.116 uVs 13:53:40 I2Y Average and RMS of Measurements VT = -226.913 +- 5.025 uVs I2Y = -20.876 +- 0.462 uTm^2 13:53:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:55 Integrated Voltage Measurement... 13:54:04 Voltage Offset Correction: v_off_ini = 142.386 uV, v_off_fin = 119.518 uV 13:54:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.934 uVs 13:54:04 Integrated Voltage Measurement... 13:54:13 Voltage Offset Correction: v_off_ini = 130.344 uV, v_off_fin = 136.821 uV 13:54:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 73.582 uVs 13:54:13 Integrated Voltage Measurement... 13:54:22 Voltage Offset Correction: v_off_ini = 143.627 uV, v_off_fin = 131.202 uV 13:54:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.095 uVs 13:54:22 Integrated Voltage Measurement... 13:54:31 Voltage Offset Correction: v_off_ini = 126.689 uV, v_off_fin = 133.036 uV 13:54:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 82.294 uVs 13:54:31 Integrated Voltage Measurement... 13:54:40 Voltage Offset Correction: v_off_ini = 139.333 uV, v_off_fin = 134.158 uV 13:54:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.275 uVs 13:54:40 Integrated Voltage Measurement... 13:54:49 Voltage Offset Correction: v_off_ini = 126.346 uV, v_off_fin = 129.345 uV 13:54:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.633 uVs 13:54:54 I1X Average and RMS of Measurements VT = -73.469 +- 8.114 uVs I1X = 14.695 +- 1.623 uTm 13:54:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:00 Integrated Voltage Measurement... 13:55:09 Voltage Offset Correction: v_off_ini = 117.941 uV, v_off_fin = 119.658 uV 13:55:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.691 uVs 13:55:09 Integrated Voltage Measurement... 13:55:18 Voltage Offset Correction: v_off_ini = 133.893 uV, v_off_fin = 139.458 uV 13:55:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.048 uVs 13:55:18 Integrated Voltage Measurement... 13:55:27 Voltage Offset Correction: v_off_ini = 131.278 uV, v_off_fin = 134.819 uV 13:55:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.215 uVs 13:55:27 Integrated Voltage Measurement... 13:55:36 Voltage Offset Correction: v_off_ini = 125.813 uV, v_off_fin = 139.199 uV 13:55:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.491 uVs 13:55:36 Integrated Voltage Measurement... 13:55:45 Voltage Offset Correction: v_off_ini = 126.703 uV, v_off_fin = 125.399 uV 13:55:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.861 uVs 13:55:45 Integrated Voltage Measurement... 13:55:54 Voltage Offset Correction: v_off_ini = 130.196 uV, v_off_fin = 141.679 uV 13:55:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.358 uVs 13:55:59 I1Y Average and RMS of Measurements VT = -210.610 +- 1.962 uVs I1Y = -42.122 +- 0.392 uTm 13:56:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:06 Integrated Voltage Measurement... 13:56:15 Voltage Offset Correction: v_off_ini = 135.610 uV, v_off_fin = 128.820 uV 13:56:15 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -58.569 uVs 13:56:15 Integrated Voltage Measurement... 13:56:24 Voltage Offset Correction: v_off_ini = 143.198 uV, v_off_fin = 154.208 uV 13:56:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.668 uVs 13:56:24 Integrated Voltage Measurement... 13:56:33 Voltage Offset Correction: v_off_ini = 132.084 uV, v_off_fin = 135.495 uV 13:56:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.767 uVs 13:56:33 Integrated Voltage Measurement... 13:56:42 Voltage Offset Correction: v_off_ini = 141.170 uV, v_off_fin = 163.066 uV 13:56:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.777 uVs 13:56:43 Integrated Voltage Measurement... 13:56:51 Voltage Offset Correction: v_off_ini = 139.086 uV, v_off_fin = 132.844 uV 13:56:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.100 uVs 13:56:52 Integrated Voltage Measurement... 13:57:00 Voltage Offset Correction: v_off_ini = 147.556 uV, v_off_fin = 152.196 uV 13:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.389 uVs 13:57:03 I2X Average and RMS of Measurements VT = -47.878 +- 2.678 uVs I2X = 4.405 +- 0.246 uTm^2 13:57:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:11 Integrated Voltage Measurement... 13:57:20 Voltage Offset Correction: v_off_ini = 128.993 uV, v_off_fin = 129.441 uV 13:57:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.842 uVs 13:57:20 Integrated Voltage Measurement... 13:57:29 Voltage Offset Correction: v_off_ini = 131.708 uV, v_off_fin = 126.267 uV 13:57:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.647 uVs 13:57:29 Integrated Voltage Measurement... 13:57:38 Voltage Offset Correction: v_off_ini = 127.769 uV, v_off_fin = 134.247 uV 13:57:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.382 uVs 13:57:38 Integrated Voltage Measurement... 13:57:47 Voltage Offset Correction: v_off_ini = 134.420 uV, v_off_fin = 141.945 uV 13:57:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.478 uVs 13:57:47 Integrated Voltage Measurement... 13:57:56 Voltage Offset Correction: v_off_ini = 128.952 uV, v_off_fin = 129.522 uV 13:57:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.961 uVs 13:57:56 Integrated Voltage Measurement... 13:58:05 Voltage Offset Correction: v_off_ini = 115.518 uV, v_off_fin = 127.569 uV 13:58:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.795 uVs 13:58:07 I2Y Average and RMS of Measurements VT = -220.351 +- 2.628 uVs I2Y = -20.272 +- 0.242 uTm^2 13:58:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:22 Integrated Voltage Measurement... 13:58:31 Voltage Offset Correction: v_off_ini = 137.554 uV, v_off_fin = 133.135 uV 13:58:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4997 mm dXY = -0.4999 mm VT = -77.275 uVs 13:58:31 Integrated Voltage Measurement... 13:58:40 Voltage Offset Correction: v_off_ini = 139.376 uV, v_off_fin = 142.220 uV 13:58:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.420 uVs 13:58:40 Integrated Voltage Measurement... 13:58:49 Voltage Offset Correction: v_off_ini = 141.082 uV, v_off_fin = 140.033 uV 13:58:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.276 uVs 13:58:49 Integrated Voltage Measurement... 13:58:58 Voltage Offset Correction: v_off_ini = 139.308 uV, v_off_fin = 139.130 uV 13:58:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.247 uVs 13:58:58 Integrated Voltage Measurement... 13:59:07 Voltage Offset Correction: v_off_ini = 139.861 uV, v_off_fin = 135.365 uV 13:59:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.339 uVs 13:59:07 Integrated Voltage Measurement... 13:59:16 Voltage Offset Correction: v_off_ini = 137.749 uV, v_off_fin = 146.674 uV 13:59:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 85.691 uVs 13:59:20 I1X Average and RMS of Measurements VT = -78.208 +- 1.498 uVs I1X = 15.643 +- 0.299 uTm 13:59:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:59:27 Integrated Voltage Measurement... 13:59:36 Voltage Offset Correction: v_off_ini = 128.797 uV, v_off_fin = 127.792 uV 13:59:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -203.185 uVs 13:59:36 Integrated Voltage Measurement... 13:59:45 Voltage Offset Correction: v_off_ini = 141.068 uV, v_off_fin = 154.682 uV 13:59:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.112 uVs 13:59:45 Integrated Voltage Measurement... 13:59:54 Voltage Offset Correction: v_off_ini = 132.884 uV, v_off_fin = 132.926 uV 13:59:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.121 uVs 13:59:54 Integrated Voltage Measurement... 14:00:03 Voltage Offset Correction: v_off_ini = 129.916 uV, v_off_fin = 148.430 uV 14:00:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.580 uVs 14:00:03 Integrated Voltage Measurement... 14:00:12 Voltage Offset Correction: v_off_ini = 135.103 uV, v_off_fin = 132.377 uV 14:00:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.114 uVs 14:00:12 Integrated Voltage Measurement... 14:00:21 Voltage Offset Correction: v_off_ini = 136.747 uV, v_off_fin = 152.090 uV 14:00:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.854 uVs 14:00:25 I1Y Average and RMS of Measurements VT = -207.327 +- 6.791 uVs I1Y = -41.466 +- 1.358 uTm 14:00:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:33 Integrated Voltage Measurement... 14:00:42 Voltage Offset Correction: v_off_ini = 144.041 uV, v_off_fin = 140.528 uV 14:00:42 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -70.993 uVs 14:00:42 Integrated Voltage Measurement... 14:00:51 Voltage Offset Correction: v_off_ini = 150.608 uV, v_off_fin = 151.749 uV 14:00:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.339 uVs 14:00:51 Integrated Voltage Measurement... 14:01:00 Voltage Offset Correction: v_off_ini = 147.778 uV, v_off_fin = 133.358 uV 14:01:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.916 uVs 14:01:00 Integrated Voltage Measurement... 14:01:09 Voltage Offset Correction: v_off_ini = 156.320 uV, v_off_fin = 165.729 uV 14:01:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.219 uVs 14:01:09 Integrated Voltage Measurement... 14:01:18 Voltage Offset Correction: v_off_ini = 156.310 uV, v_off_fin = 152.216 uV 14:01:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.718 uVs 14:01:18 Integrated Voltage Measurement... 14:01:27 Voltage Offset Correction: v_off_ini = 141.851 uV, v_off_fin = 153.607 uV 14:01:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.112 uVs 14:01:29 I2X Average and RMS of Measurements VT = -61.550 +- 6.724 uVs I2X = 5.662 +- 0.618 uTm^2 14:01:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:37 Integrated Voltage Measurement... 14:01:46 Voltage Offset Correction: v_off_ini = 148.070 uV, v_off_fin = 153.897 uV 14:01:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.073 uVs 14:01:46 Integrated Voltage Measurement... 14:01:55 Voltage Offset Correction: v_off_ini = 145.024 uV, v_off_fin = 145.248 uV 14:01:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.772 uVs 14:01:55 Integrated Voltage Measurement... 14:02:04 Voltage Offset Correction: v_off_ini = 151.838 uV, v_off_fin = 161.234 uV 14:02:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.985 uVs 14:02:04 Integrated Voltage Measurement... 14:02:13 Voltage Offset Correction: v_off_ini = 163.689 uV, v_off_fin = 156.652 uV 14:02:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.440 uVs 14:02:13 Integrated Voltage Measurement... 14:02:22 Voltage Offset Correction: v_off_ini = 157.441 uV, v_off_fin = 154.527 uV 14:02:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.199 uVs 14:02:22 Integrated Voltage Measurement... 14:02:31 Voltage Offset Correction: v_off_ini = 163.527 uV, v_off_fin = 161.371 uV 14:02:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.405 uVs 14:02:33 I2Y Average and RMS of Measurements VT = -206.479 +- 6.918 uVs I2Y = -18.996 +- 0.636 uTm^2 14:02:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:48 Integrated Voltage Measurement... 14:02:57 Voltage Offset Correction: v_off_ini = 184.251 uV, v_off_fin = 173.494 uV 14:02:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -77.861 uVs 14:02:57 Integrated Voltage Measurement... 14:03:06 Voltage Offset Correction: v_off_ini = 171.594 uV, v_off_fin = 178.484 uV 14:03:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.053 uVs 14:03:06 Integrated Voltage Measurement... 14:03:15 Voltage Offset Correction: v_off_ini = 176.223 uV, v_off_fin = 183.628 uV 14:03:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.402 uVs 14:03:15 Integrated Voltage Measurement... 14:03:24 Voltage Offset Correction: v_off_ini = 186.259 uV, v_off_fin = 186.183 uV 14:03:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.168 uVs 14:03:24 Integrated Voltage Measurement... 14:03:33 Voltage Offset Correction: v_off_ini = 192.639 uV, v_off_fin = 191.143 uV 14:03:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.335 uVs 14:03:33 Integrated Voltage Measurement... 14:03:42 Voltage Offset Correction: v_off_ini = 187.452 uV, v_off_fin = 197.250 uV 14:03:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.800 uVs 14:03:46 I1X Average and RMS of Measurements VT = -80.270 +- 2.231 uVs I1X = 16.055 +- 0.446 uTm 14:03:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:53 Integrated Voltage Measurement... 14:04:02 Voltage Offset Correction: v_off_ini = 184.267 uV, v_off_fin = 183.283 uV 14:04:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -221.174 uVs 14:04:02 Integrated Voltage Measurement... 14:04:11 Voltage Offset Correction: v_off_ini = 193.579 uV, v_off_fin = 207.804 uV 14:04:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.148 uVs 14:04:11 Integrated Voltage Measurement... 14:04:20 Voltage Offset Correction: v_off_ini = 198.573 uV, v_off_fin = 187.514 uV 14:04:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.090 uVs 14:04:20 Integrated Voltage Measurement... 14:04:29 Voltage Offset Correction: v_off_ini = 193.849 uV, v_off_fin = 208.400 uV 14:04:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.677 uVs 14:04:29 Integrated Voltage Measurement... 14:04:38 Voltage Offset Correction: v_off_ini = 199.616 uV, v_off_fin = 193.688 uV 14:04:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.737 uVs 14:04:38 Integrated Voltage Measurement... 14:04:47 Voltage Offset Correction: v_off_ini = 202.201 uV, v_off_fin = 210.809 uV 14:04:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.097 uVs 14:04:51 I1Y Average and RMS of Measurements VT = -207.987 +- 0.641 uVs I1Y = -41.599 +- 0.129 uTm 14:04:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:59 Integrated Voltage Measurement... 14:05:08 Voltage Offset Correction: v_off_ini = 183.705 uV, v_off_fin = 175.196 uV 14:05:08 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -82.075 uVs 14:05:08 Integrated Voltage Measurement... 14:05:17 Voltage Offset Correction: v_off_ini = 186.005 uV, v_off_fin = 198.722 uV 14:05:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.413 uVs 14:05:17 Integrated Voltage Measurement... 14:05:26 Voltage Offset Correction: v_off_ini = 191.927 uV, v_off_fin = 181.327 uV 14:05:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.308 uVs 14:05:26 Integrated Voltage Measurement... 14:05:35 Voltage Offset Correction: v_off_ini = 188.854 uV, v_off_fin = 204.371 uV 14:05:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.168 uVs 14:05:35 Integrated Voltage Measurement... 14:05:44 Voltage Offset Correction: v_off_ini = 192.018 uV, v_off_fin = 172.643 uV 14:05:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.269 uVs 14:05:44 Integrated Voltage Measurement... 14:05:53 Voltage Offset Correction: v_off_ini = 182.262 uV, v_off_fin = 185.892 uV 14:05:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.281 uVs 14:05:55 I2X Average and RMS of Measurements VT = -67.752 +- 2.960 uVs I2X = 6.233 +- 0.272 uTm^2 14:06:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:03 Integrated Voltage Measurement... 14:06:12 Voltage Offset Correction: v_off_ini = 201.690 uV, v_off_fin = 186.759 uV 14:06:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -198.526 uVs 14:06:12 Integrated Voltage Measurement... 14:06:21 Voltage Offset Correction: v_off_ini = 181.813 uV, v_off_fin = 191.035 uV 14:06:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.459 uVs 14:06:21 Integrated Voltage Measurement... 14:06:30 Voltage Offset Correction: v_off_ini = 188.258 uV, v_off_fin = 191.428 uV 14:06:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.329 uVs 14:06:30 Integrated Voltage Measurement... 14:06:39 Voltage Offset Correction: v_off_ini = 193.707 uV, v_off_fin = 199.203 uV 14:06:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.950 uVs 14:06:39 Integrated Voltage Measurement... 14:06:48 Voltage Offset Correction: v_off_ini = 210.194 uV, v_off_fin = 207.578 uV 14:06:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.691 uVs 14:06:48 Integrated Voltage Measurement... 14:06:57 Voltage Offset Correction: v_off_ini = 197.493 uV, v_off_fin = 204.160 uV 14:06:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.076 uVs 14:07:00 I2Y Average and RMS of Measurements VT = -208.838 +- 8.286 uVs I2Y = -19.213 +- 0.762 uTm^2 14:07:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:15 Integrated Voltage Measurement... 14:07:23 Voltage Offset Correction: v_off_ini = 183.063 uV, v_off_fin = 195.641 uV 14:07:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.606 uVs 14:07:24 Integrated Voltage Measurement... 14:07:32 Voltage Offset Correction: v_off_ini = 191.605 uV, v_off_fin = 189.830 uV 14:07:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 93.416 uVs 14:07:33 Integrated Voltage Measurement... 14:07:41 Voltage Offset Correction: v_off_ini = 186.810 uV, v_off_fin = 193.543 uV 14:07:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.527 uVs 14:07:42 Integrated Voltage Measurement... 14:07:51 Voltage Offset Correction: v_off_ini = 198.576 uV, v_off_fin = 191.495 uV 14:07:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.558 uVs 14:07:51 Integrated Voltage Measurement... 14:08:00 Voltage Offset Correction: v_off_ini = 204.021 uV, v_off_fin = 197.129 uV 14:08:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -97.219 uVs 14:08:00 Integrated Voltage Measurement... 14:08:09 Voltage Offset Correction: v_off_ini = 196.900 uV, v_off_fin = 206.910 uV 14:08:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 83.798 uVs 14:08:13 I1X Average and RMS of Measurements VT = -89.187 +- 2.233 uVs I1X = 17.840 +- 0.447 uTm 14:08:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:20 Integrated Voltage Measurement... 14:08:28 Voltage Offset Correction: v_off_ini = 216.729 uV, v_off_fin = 208.782 uV 14:08:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.472 uVs 14:08:28 Integrated Voltage Measurement... 14:08:37 Voltage Offset Correction: v_off_ini = 217.184 uV, v_off_fin = 228.524 uV 14:08:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.743 uVs 14:08:37 Integrated Voltage Measurement... 14:08:46 Voltage Offset Correction: v_off_ini = 216.550 uV, v_off_fin = 205.305 uV 14:08:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.383 uVs 14:08:46 Integrated Voltage Measurement... 14:08:55 Voltage Offset Correction: v_off_ini = 215.941 uV, v_off_fin = 225.067 uV 14:08:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.469 uVs 14:08:55 Integrated Voltage Measurement... 14:09:04 Voltage Offset Correction: v_off_ini = 217.371 uV, v_off_fin = 206.488 uV 14:09:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.819 uVs 14:09:04 Integrated Voltage Measurement... 14:09:13 Voltage Offset Correction: v_off_ini = 224.331 uV, v_off_fin = 223.829 uV 14:09:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.074 uVs 14:09:18 I1Y Average and RMS of Measurements VT = -198.660 +- 5.958 uVs I1Y = -39.729 +- 1.193 uTm 14:09:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:25 Integrated Voltage Measurement... 14:09:34 Voltage Offset Correction: v_off_ini = 224.054 uV, v_off_fin = 219.323 uV 14:09:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -58.264 uVs 14:09:34 Integrated Voltage Measurement... 14:09:43 Voltage Offset Correction: v_off_ini = 233.415 uV, v_off_fin = 238.489 uV 14:09:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.672 uVs 14:09:43 Integrated Voltage Measurement... 14:09:52 Voltage Offset Correction: v_off_ini = 223.296 uV, v_off_fin = 217.314 uV 14:09:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.736 uVs 14:09:52 Integrated Voltage Measurement... 14:10:01 Voltage Offset Correction: v_off_ini = 230.189 uV, v_off_fin = 231.452 uV 14:10:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.063 uVs 14:10:01 Integrated Voltage Measurement... 14:10:10 Voltage Offset Correction: v_off_ini = 228.850 uV, v_off_fin = 219.338 uV 14:10:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.277 uVs 14:10:10 Integrated Voltage Measurement... 14:10:19 Voltage Offset Correction: v_off_ini = 223.749 uV, v_off_fin = 235.879 uV 14:10:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.568 uVs 14:10:22 I2X Average and RMS of Measurements VT = -59.430 +- 1.605 uVs I2X = 5.467 +- 0.148 uTm^2 14:10:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:10:29 Integrated Voltage Measurement... 14:10:38 Voltage Offset Correction: v_off_ini = 224.892 uV, v_off_fin = 228.642 uV 14:10:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.648 uVs 14:10:38 Integrated Voltage Measurement... 14:10:47 Voltage Offset Correction: v_off_ini = 224.330 uV, v_off_fin = 227.065 uV 14:10:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.280 uVs 14:10:48 Integrated Voltage Measurement... 14:10:56 Voltage Offset Correction: v_off_ini = 229.241 uV, v_off_fin = 230.704 uV 14:10:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.709 uVs 14:10:57 Integrated Voltage Measurement... 14:11:05 Voltage Offset Correction: v_off_ini = 233.637 uV, v_off_fin = 222.244 uV 14:11:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.981 uVs 14:11:06 Integrated Voltage Measurement... 14:11:15 Voltage Offset Correction: v_off_ini = 230.405 uV, v_off_fin = 228.037 uV 14:11:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.458 uVs 14:11:15 Integrated Voltage Measurement... 14:11:24 Voltage Offset Correction: v_off_ini = 231.009 uV, v_off_fin = 227.032 uV 14:11:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.565 uVs 14:11:26 I2Y Average and RMS of Measurements VT = -208.107 +- 2.425 uVs I2Y = -19.146 +- 0.223 uTm^2 14:11:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:41 Integrated Voltage Measurement... 14:11:50 Voltage Offset Correction: v_off_ini = 238.840 uV, v_off_fin = 225.154 uV 14:11:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -77.308 uVs 14:11:50 Integrated Voltage Measurement... 14:11:59 Voltage Offset Correction: v_off_ini = 231.456 uV, v_off_fin = 242.735 uV 14:11:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.473 uVs 14:11:59 Integrated Voltage Measurement... 14:12:08 Voltage Offset Correction: v_off_ini = 245.514 uV, v_off_fin = 232.418 uV 14:12:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.458 uVs 14:12:08 Integrated Voltage Measurement... 14:12:17 Voltage Offset Correction: v_off_ini = 242.419 uV, v_off_fin = 238.564 uV 14:12:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.525 uVs 14:12:17 Integrated Voltage Measurement... 14:12:26 Voltage Offset Correction: v_off_ini = 215.651 uV, v_off_fin = 227.570 uV 14:12:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.212 uVs 14:12:26 Integrated Voltage Measurement... 14:12:35 Voltage Offset Correction: v_off_ini = 225.749 uV, v_off_fin = 234.155 uV 14:12:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 84.747 uVs 14:12:39 I1X Average and RMS of Measurements VT = -80.454 +- 6.937 uVs I1X = 16.092 +- 1.388 uTm 14:12:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:12:46 Integrated Voltage Measurement... 14:12:55 Voltage Offset Correction: v_off_ini = 236.198 uV, v_off_fin = 228.186 uV 14:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -200.131 uVs 14:12:55 Integrated Voltage Measurement... 14:13:04 Voltage Offset Correction: v_off_ini = 251.792 uV, v_off_fin = 252.962 uV 14:13:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.251 uVs 14:13:04 Integrated Voltage Measurement... 14:13:13 Voltage Offset Correction: v_off_ini = 247.803 uV, v_off_fin = 237.874 uV 14:13:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -203.728 uVs 14:13:13 Integrated Voltage Measurement... 14:13:22 Voltage Offset Correction: v_off_ini = 244.495 uV, v_off_fin = 244.263 uV 14:13:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.363 uVs 14:13:22 Integrated Voltage Measurement... 14:13:31 Voltage Offset Correction: v_off_ini = 242.000 uV, v_off_fin = 225.437 uV 14:13:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5002 mm dXY = 0.5001 mm VT = -211.489 uVs 14:13:31 Integrated Voltage Measurement... 14:13:40 Voltage Offset Correction: v_off_ini = 239.779 uV, v_off_fin = 248.243 uV 14:13:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 213.364 uVs 14:13:44 I1Y Average and RMS of Measurements VT = -205.721 +- 4.863 uVs I1Y = -41.141 +- 0.969 uTm 14:13:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:13:52 Integrated Voltage Measurement... 14:14:01 Voltage Offset Correction: v_off_ini = 222.377 uV, v_off_fin = 214.713 uV 14:14:01 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -82.604 uVs 14:14:01 Integrated Voltage Measurement... 14:14:10 Voltage Offset Correction: v_off_ini = 230.671 uV, v_off_fin = 234.597 uV 14:14:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.359 uVs 14:14:10 Integrated Voltage Measurement... 14:14:19 Voltage Offset Correction: v_off_ini = 213.278 uV, v_off_fin = 201.009 uV 14:14:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.422 uVs 14:14:19 Integrated Voltage Measurement... 14:14:28 Voltage Offset Correction: v_off_ini = 204.481 uV, v_off_fin = 226.306 uV 14:14:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.795 uVs 14:14:28 Integrated Voltage Measurement... 14:14:37 Voltage Offset Correction: v_off_ini = 217.737 uV, v_off_fin = 190.629 uV 14:14:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.341 uVs 14:14:37 Integrated Voltage Measurement... 14:14:46 Voltage Offset Correction: v_off_ini = 199.159 uV, v_off_fin = 216.367 uV 14:14:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.195 uVs 14:14:48 I2X Average and RMS of Measurements VT = -80.286 +- 6.376 uVs I2X = 7.386 +- 0.587 uTm^2 14:14:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:56 Integrated Voltage Measurement... 14:15:05 Voltage Offset Correction: v_off_ini = 201.821 uV, v_off_fin = 200.770 uV 14:15:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.586 uVs 14:15:05 Integrated Voltage Measurement... 14:15:14 Voltage Offset Correction: v_off_ini = 213.500 uV, v_off_fin = 207.254 uV 14:15:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.219 uVs 14:15:14 Integrated Voltage Measurement... 14:15:23 Voltage Offset Correction: v_off_ini = 208.515 uV, v_off_fin = 213.199 uV 14:15:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.061 uVs 14:15:23 Integrated Voltage Measurement... 14:15:32 Voltage Offset Correction: v_off_ini = 219.261 uV, v_off_fin = 215.391 uV 14:15:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.792 uVs 14:15:32 Integrated Voltage Measurement... 14:15:41 Voltage Offset Correction: v_off_ini = 223.891 uV, v_off_fin = 220.205 uV 14:15:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.253 uVs 14:15:41 Integrated Voltage Measurement... 14:15:50 Voltage Offset Correction: v_off_ini = 217.544 uV, v_off_fin = 213.736 uV 14:15:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.567 uVs 14:15:53 I2Y Average and RMS of Measurements VT = -207.580 +- 4.079 uVs I2Y = -19.097 +- 0.375 uTm^2 14:16:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:08 Integrated Voltage Measurement... 14:16:17 Voltage Offset Correction: v_off_ini = 223.347 uV, v_off_fin = 209.284 uV 14:16:17 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -91.433 uVs 14:16:17 Integrated Voltage Measurement... 14:16:26 Voltage Offset Correction: v_off_ini = 201.203 uV, v_off_fin = 214.364 uV 14:16:26 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 110.619 uVs 14:16:26 Integrated Voltage Measurement... 14:16:35 Voltage Offset Correction: v_off_ini = 221.921 uV, v_off_fin = 217.496 uV 14:16:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.897 uVs 14:16:35 Integrated Voltage Measurement... 14:16:44 Voltage Offset Correction: v_off_ini = 219.880 uV, v_off_fin = 223.699 uV 14:16:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.623 uVs 14:16:44 Integrated Voltage Measurement... 14:16:53 Voltage Offset Correction: v_off_ini = 212.306 uV, v_off_fin = 220.149 uV 14:16:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -94.016 uVs 14:16:53 Integrated Voltage Measurement... 14:17:02 Voltage Offset Correction: v_off_ini = 224.623 uV, v_off_fin = 222.114 uV 14:17:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.691 uVs 14:17:06 I1X Average and RMS of Measurements VT = -98.880 +- 4.320 uVs I1X = 19.779 +- 0.865 uTm 14:17:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:13 Integrated Voltage Measurement... 14:17:22 Voltage Offset Correction: v_off_ini = 217.407 uV, v_off_fin = 216.202 uV 14:17:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.307 uVs 14:17:22 Integrated Voltage Measurement... 14:17:31 Voltage Offset Correction: v_off_ini = 227.734 uV, v_off_fin = 244.530 uV 14:17:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.024 uVs 14:17:31 Integrated Voltage Measurement... 14:17:40 Voltage Offset Correction: v_off_ini = 209.857 uV, v_off_fin = 213.146 uV 14:17:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.799 uVs 14:17:40 Integrated Voltage Measurement... 14:17:49 Voltage Offset Correction: v_off_ini = 215.157 uV, v_off_fin = 230.336 uV 14:17:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.295 uVs 14:17:49 Integrated Voltage Measurement... 14:17:58 Voltage Offset Correction: v_off_ini = 225.550 uV, v_off_fin = 221.554 uV 14:17:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -193.077 uVs 14:17:58 Integrated Voltage Measurement... 14:18:07 Voltage Offset Correction: v_off_ini = 222.703 uV, v_off_fin = 236.088 uV 14:18:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.442 uVs 14:18:11 I1Y Average and RMS of Measurements VT = -197.657 +- 2.877 uVs I1Y = -39.528 +- 0.576 uTm 14:18:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:19 Integrated Voltage Measurement... 14:18:28 Voltage Offset Correction: v_off_ini = 241.654 uV, v_off_fin = 236.457 uV 14:18:28 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -85.705 uVs 14:18:28 Integrated Voltage Measurement... 14:18:37 Voltage Offset Correction: v_off_ini = 249.463 uV, v_off_fin = 256.150 uV 14:18:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.522 uVs 14:18:37 Integrated Voltage Measurement... 14:18:46 Voltage Offset Correction: v_off_ini = 241.731 uV, v_off_fin = 231.516 uV 14:18:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.008 uVs 14:18:46 Integrated Voltage Measurement... 14:18:55 Voltage Offset Correction: v_off_ini = 248.233 uV, v_off_fin = 231.594 uV 14:18:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.688 uVs 14:18:55 Integrated Voltage Measurement... 14:19:04 Voltage Offset Correction: v_off_ini = 228.071 uV, v_off_fin = 215.985 uV 14:19:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.920 uVs 14:19:04 Integrated Voltage Measurement... 14:19:13 Voltage Offset Correction: v_off_ini = 231.097 uV, v_off_fin = 241.791 uV 14:19:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.768 uVs 14:19:15 I2X Average and RMS of Measurements VT = -75.102 +- 2.656 uVs I2X = 6.909 +- 0.244 uTm^2 14:19:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:23 Integrated Voltage Measurement... 14:19:32 Voltage Offset Correction: v_off_ini = 236.875 uV, v_off_fin = 236.570 uV 14:19:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.889 uVs 14:19:32 Integrated Voltage Measurement... 14:19:41 Voltage Offset Correction: v_off_ini = 233.484 uV, v_off_fin = 231.753 uV 14:19:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.076 uVs 14:19:41 Integrated Voltage Measurement... 14:19:50 Voltage Offset Correction: v_off_ini = 220.922 uV, v_off_fin = 235.142 uV 14:19:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.208 uVs 14:19:50 Integrated Voltage Measurement... 14:19:59 Voltage Offset Correction: v_off_ini = 235.263 uV, v_off_fin = 232.502 uV 14:19:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.713 uVs 14:19:59 Integrated Voltage Measurement... 14:20:08 Voltage Offset Correction: v_off_ini = 236.686 uV, v_off_fin = 228.795 uV 14:20:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.086 uVs 14:20:08 Integrated Voltage Measurement... 14:20:17 Voltage Offset Correction: v_off_ini = 236.899 uV, v_off_fin = 221.877 uV 14:20:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.175 uVs 14:20:19 I2Y Average and RMS of Measurements VT = -199.691 +- 4.911 uVs I2Y = -18.372 +- 0.452 uTm^2 14:20:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:34 Integrated Voltage Measurement... 14:20:43 Voltage Offset Correction: v_off_ini = 225.915 uV, v_off_fin = 236.333 uV 14:20:43 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -95.190 uVs 14:20:43 Integrated Voltage Measurement... 14:20:52 Voltage Offset Correction: v_off_ini = 229.365 uV, v_off_fin = 238.925 uV 14:20:52 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.441 uVs 14:20:52 Integrated Voltage Measurement... 14:21:01 Voltage Offset Correction: v_off_ini = 236.334 uV, v_off_fin = 235.865 uV 14:21:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.234 uVs 14:21:01 Integrated Voltage Measurement... 14:21:10 Voltage Offset Correction: v_off_ini = 235.993 uV, v_off_fin = 247.839 uV 14:21:10 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 107.025 uVs 14:21:10 Integrated Voltage Measurement... 14:21:19 Voltage Offset Correction: v_off_ini = 246.636 uV, v_off_fin = 251.172 uV 14:21:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.762 uVs 14:21:19 Integrated Voltage Measurement... 14:21:28 Voltage Offset Correction: v_off_ini = 248.716 uV, v_off_fin = 251.525 uV 14:21:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.787 uVs 14:21:33 I1X Average and RMS of Measurements VT = -97.240 +- 5.094 uVs I1X = 19.451 +- 1.021 uTm 14:21:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:21:39 Integrated Voltage Measurement... 14:21:48 Voltage Offset Correction: v_off_ini = 233.367 uV, v_off_fin = 226.668 uV 14:21:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.422 uVs 14:21:48 Integrated Voltage Measurement... 14:21:57 Voltage Offset Correction: v_off_ini = 244.660 uV, v_off_fin = 267.466 uV 14:21:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 187.777 uVs 14:21:57 Integrated Voltage Measurement... 14:22:06 Voltage Offset Correction: v_off_ini = 239.706 uV, v_off_fin = 236.043 uV 14:22:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.720 uVs 14:22:06 Integrated Voltage Measurement... 14:22:15 Voltage Offset Correction: v_off_ini = 239.725 uV, v_off_fin = 247.725 uV 14:22:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.036 uVs 14:22:15 Integrated Voltage Measurement... 14:22:24 Voltage Offset Correction: v_off_ini = 236.247 uV, v_off_fin = 237.279 uV 14:22:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.196 uVs 14:22:24 Integrated Voltage Measurement... 14:22:33 Voltage Offset Correction: v_off_ini = 246.449 uV, v_off_fin = 247.438 uV 14:22:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.631 uVs 14:22:38 I1Y Average and RMS of Measurements VT = -186.130 +- 3.114 uVs I1Y = -37.224 +- 0.622 uTm 14:22:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:22:45 Integrated Voltage Measurement... 14:22:54 Voltage Offset Correction: v_off_ini = 242.583 uV, v_off_fin = 235.370 uV 14:22:54 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -92.125 uVs 14:22:54 Integrated Voltage Measurement... 14:23:03 Voltage Offset Correction: v_off_ini = 246.545 uV, v_off_fin = 266.387 uV 14:23:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.045 uVs 14:23:03 Integrated Voltage Measurement... 14:23:12 Voltage Offset Correction: v_off_ini = 248.968 uV, v_off_fin = 242.023 uV 14:23:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.069 uVs 14:23:12 Integrated Voltage Measurement... 14:23:21 Voltage Offset Correction: v_off_ini = 243.874 uV, v_off_fin = 255.246 uV 14:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.694 uVs 14:23:21 Integrated Voltage Measurement... 14:23:30 Voltage Offset Correction: v_off_ini = 255.227 uV, v_off_fin = 233.916 uV 14:23:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.606 uVs 14:23:31 Integrated Voltage Measurement... 14:23:39 Voltage Offset Correction: v_off_ini = 251.321 uV, v_off_fin = 262.124 uV 14:23:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.433 uVs 14:23:42 I2X Average and RMS of Measurements VT = -79.662 +- 2.929 uVs I2X = 7.329 +- 0.269 uTm^2 14:23:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:23:50 Integrated Voltage Measurement... 14:23:59 Voltage Offset Correction: v_off_ini = 226.979 uV, v_off_fin = 238.944 uV 14:23:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.203 uVs 14:23:59 Integrated Voltage Measurement... 14:24:08 Voltage Offset Correction: v_off_ini = 256.706 uV, v_off_fin = 245.927 uV 14:24:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.848 uVs 14:24:08 Integrated Voltage Measurement... 14:24:17 Voltage Offset Correction: v_off_ini = 242.374 uV, v_off_fin = 242.601 uV 14:24:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.732 uVs 14:24:17 Integrated Voltage Measurement... 14:24:26 Voltage Offset Correction: v_off_ini = 249.103 uV, v_off_fin = 240.643 uV 14:24:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.988 uVs 14:24:26 Integrated Voltage Measurement... 14:24:35 Voltage Offset Correction: v_off_ini = 247.752 uV, v_off_fin = 248.292 uV 14:24:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.360 uVs 14:24:35 Integrated Voltage Measurement... 14:24:44 Voltage Offset Correction: v_off_ini = 248.028 uV, v_off_fin = 254.981 uV 14:24:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.087 uVs 14:24:46 I2Y Average and RMS of Measurements VT = -191.537 +- 1.835 uVs I2Y = -17.621 +- 0.169 uTm^2 14:24:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:01 Integrated Voltage Measurement... 14:25:10 Voltage Offset Correction: v_off_ini = 236.716 uV, v_off_fin = 246.515 uV 14:25:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.924 uVs 14:25:10 Integrated Voltage Measurement... 14:25:19 Voltage Offset Correction: v_off_ini = 248.403 uV, v_off_fin = 243.307 uV 14:25:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 97.038 uVs 14:25:19 Integrated Voltage Measurement... 14:25:28 Voltage Offset Correction: v_off_ini = 246.982 uV, v_off_fin = 245.541 uV 14:25:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -96.974 uVs 14:25:28 Integrated Voltage Measurement... 14:25:37 Voltage Offset Correction: v_off_ini = 242.858 uV, v_off_fin = 258.915 uV 14:25:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 91.278 uVs 14:25:37 Integrated Voltage Measurement... 14:25:46 Voltage Offset Correction: v_off_ini = 264.075 uV, v_off_fin = 249.462 uV 14:25:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.240 uVs 14:25:46 Integrated Voltage Measurement... 14:25:55 Voltage Offset Correction: v_off_ini = 251.482 uV, v_off_fin = 244.790 uV 14:25:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.127 uVs 14:25:59 I1X Average and RMS of Measurements VT = -92.763 +- 8.304 uVs I1X = 18.554 +- 1.660 uTm 14:26:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:06 Integrated Voltage Measurement... 14:26:15 Voltage Offset Correction: v_off_ini = 236.967 uV, v_off_fin = 241.161 uV 14:26:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.731 uVs 14:26:15 Integrated Voltage Measurement... 14:26:24 Voltage Offset Correction: v_off_ini = 256.932 uV, v_off_fin = 267.022 uV 14:26:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 190.290 uVs 14:26:24 Integrated Voltage Measurement... 14:26:33 Voltage Offset Correction: v_off_ini = 237.593 uV, v_off_fin = 237.126 uV 14:26:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.625 uVs 14:26:33 Integrated Voltage Measurement... 14:26:42 Voltage Offset Correction: v_off_ini = 236.037 uV, v_off_fin = 263.069 uV 14:26:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.966 uVs 14:26:42 Integrated Voltage Measurement... 14:26:51 Voltage Offset Correction: v_off_ini = 250.924 uV, v_off_fin = 240.432 uV 14:26:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.621 uVs 14:26:51 Integrated Voltage Measurement... 14:27:00 Voltage Offset Correction: v_off_ini = 238.944 uV, v_off_fin = 259.097 uV 14:27:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.711 uVs 14:27:04 I1Y Average and RMS of Measurements VT = -194.324 +- 7.377 uVs I1Y = -38.864 +- 1.476 uTm 14:27:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:27:12 Integrated Voltage Measurement... 14:27:21 Voltage Offset Correction: v_off_ini = 257.452 uV, v_off_fin = 248.552 uV 14:27:21 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -91.743 uVs 14:27:21 Integrated Voltage Measurement... 14:27:30 Voltage Offset Correction: v_off_ini = 261.444 uV, v_off_fin = 274.903 uV 14:27:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.818 uVs 14:27:30 Integrated Voltage Measurement... 14:27:39 Voltage Offset Correction: v_off_ini = 271.830 uV, v_off_fin = 265.667 uV 14:27:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.526 uVs 14:27:39 Integrated Voltage Measurement... 14:27:48 Voltage Offset Correction: v_off_ini = 275.330 uV, v_off_fin = 276.865 uV 14:27:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.805 uVs 14:27:48 Integrated Voltage Measurement... 14:27:57 Voltage Offset Correction: v_off_ini = 260.585 uV, v_off_fin = 264.788 uV 14:27:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.306 uVs 14:27:57 Integrated Voltage Measurement... 14:28:06 Voltage Offset Correction: v_off_ini = 273.201 uV, v_off_fin = 269.956 uV 14:28:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 47.022 uVs 14:28:09 I2X Average and RMS of Measurements VT = -72.703 +- 8.015 uVs I2X = 6.689 +- 0.737 uTm^2 14:28:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:16 Integrated Voltage Measurement... 14:28:25 Voltage Offset Correction: v_off_ini = 274.064 uV, v_off_fin = 267.613 uV 14:28:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.489 uVs 14:28:26 Integrated Voltage Measurement... 14:28:35 Voltage Offset Correction: v_off_ini = 272.755 uV, v_off_fin = 260.341 uV 14:28:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.654 uVs 14:28:35 Integrated Voltage Measurement... 14:28:44 Voltage Offset Correction: v_off_ini = 261.494 uV, v_off_fin = 266.102 uV 14:28:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.627 uVs 14:28:44 Integrated Voltage Measurement... 14:28:53 Voltage Offset Correction: v_off_ini = 264.906 uV, v_off_fin = 262.578 uV 14:28:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.239 uVs 14:28:53 Integrated Voltage Measurement... 14:29:02 Voltage Offset Correction: v_off_ini = 273.501 uV, v_off_fin = 276.292 uV 14:29:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.279 uVs 14:29:02 Integrated Voltage Measurement... 14:29:11 Voltage Offset Correction: v_off_ini = 268.270 uV, v_off_fin = 271.079 uV 14:29:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.138 uVs 14:29:13 I2Y Average and RMS of Measurements VT = -197.071 +- 5.804 uVs I2Y = -18.131 +- 0.534 uTm^2 14:29:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:28 Integrated Voltage Measurement... 14:29:37 Voltage Offset Correction: v_off_ini = 285.866 uV, v_off_fin = 278.095 uV 14:29:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4997 mm dXY = -0.4998 mm VT = -110.471 uVs 14:29:37 Integrated Voltage Measurement... 14:29:46 Voltage Offset Correction: v_off_ini = 268.427 uV, v_off_fin = 281.294 uV 14:29:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 119.808 uVs 14:29:46 Integrated Voltage Measurement... 14:29:55 Voltage Offset Correction: v_off_ini = 278.478 uV, v_off_fin = 272.780 uV 14:29:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.231 uVs 14:29:55 Integrated Voltage Measurement... 14:30:04 Voltage Offset Correction: v_off_ini = 270.256 uV, v_off_fin = 272.219 uV 14:30:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.099 uVs 14:30:04 Integrated Voltage Measurement... 14:30:13 Voltage Offset Correction: v_off_ini = 275.029 uV, v_off_fin = 275.312 uV 14:30:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.836 uVs 14:30:13 Integrated Voltage Measurement... 14:30:22 Voltage Offset Correction: v_off_ini = 275.173 uV, v_off_fin = 273.294 uV 14:30:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.998 uVs 14:30:26 I1X Average and RMS of Measurements VT = -102.407 +- 9.358 uVs I1X = 20.483 +- 1.874 uTm 14:30:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:33 Integrated Voltage Measurement... 14:30:42 Voltage Offset Correction: v_off_ini = 276.279 uV, v_off_fin = 275.141 uV 14:30:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -201.789 uVs 14:30:42 Integrated Voltage Measurement... 14:30:51 Voltage Offset Correction: v_off_ini = 273.561 uV, v_off_fin = 287.571 uV 14:30:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.891 uVs 14:30:51 Integrated Voltage Measurement... 14:31:00 Voltage Offset Correction: v_off_ini = 271.156 uV, v_off_fin = 259.929 uV 14:31:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.823 uVs 14:31:00 Integrated Voltage Measurement... 14:31:09 Voltage Offset Correction: v_off_ini = 264.673 uV, v_off_fin = 272.385 uV 14:31:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.071 uVs 14:31:09 Integrated Voltage Measurement... 14:31:18 Voltage Offset Correction: v_off_ini = 273.335 uV, v_off_fin = 264.097 uV 14:31:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.907 uVs 14:31:18 Integrated Voltage Measurement... 14:31:27 Voltage Offset Correction: v_off_ini = 280.743 uV, v_off_fin = 291.170 uV 14:31:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.097 uVs 14:31:31 I1Y Average and RMS of Measurements VT = -200.763 +- 2.360 uVs I1Y = -40.153 +- 0.472 uTm 14:31:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:39 Integrated Voltage Measurement... 14:31:48 Voltage Offset Correction: v_off_ini = 294.802 uV, v_off_fin = 281.694 uV 14:31:48 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -104.678 uVs 14:31:48 Integrated Voltage Measurement... 14:31:57 Voltage Offset Correction: v_off_ini = 281.314 uV, v_off_fin = 296.249 uV 14:31:57 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.459 uVs 14:31:57 Integrated Voltage Measurement... 14:32:06 Voltage Offset Correction: v_off_ini = 289.882 uV, v_off_fin = 282.615 uV 14:32:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.987 uVs 14:32:06 Integrated Voltage Measurement... 14:32:15 Voltage Offset Correction: v_off_ini = 285.342 uV, v_off_fin = 298.839 uV 14:32:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.493 uVs 14:32:15 Integrated Voltage Measurement... 14:32:24 Voltage Offset Correction: v_off_ini = 294.170 uV, v_off_fin = 282.365 uV 14:32:24 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -79.571 uVs 14:32:24 Integrated Voltage Measurement... 14:32:33 Voltage Offset Correction: v_off_ini = 285.305 uV, v_off_fin = 290.418 uV 14:32:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.906 uVs 14:32:36 I2X Average and RMS of Measurements VT = -85.349 +- 4.668 uVs I2X = 7.853 +- 0.429 uTm^2 14:32:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:32:43 Integrated Voltage Measurement... 14:32:52 Voltage Offset Correction: v_off_ini = 281.191 uV, v_off_fin = 297.359 uV 14:32:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.272 uVs 14:32:52 Integrated Voltage Measurement... 14:33:01 Voltage Offset Correction: v_off_ini = 294.488 uV, v_off_fin = 285.963 uV 14:33:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.844 uVs 14:33:01 Integrated Voltage Measurement... 14:33:10 Voltage Offset Correction: v_off_ini = 294.803 uV, v_off_fin = 296.985 uV 14:33:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.816 uVs 14:33:11 Integrated Voltage Measurement... 14:33:19 Voltage Offset Correction: v_off_ini = 290.011 uV, v_off_fin = 313.944 uV 14:33:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.770 uVs 14:33:20 Integrated Voltage Measurement... 14:33:29 Voltage Offset Correction: v_off_ini = 310.500 uV, v_off_fin = 299.562 uV 14:33:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.094 uVs 14:33:29 Integrated Voltage Measurement... 14:33:38 Voltage Offset Correction: v_off_ini = 299.636 uV, v_off_fin = 296.727 uV 14:33:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.229 uVs 14:33:40 I2Y Average and RMS of Measurements VT = -196.837 +- 3.240 uVs I2Y = -18.109 +- 0.298 uTm^2 14:33:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:33:56 Integrated Voltage Measurement... 14:34:05 Voltage Offset Correction: v_off_ini = 298.312 uV, v_off_fin = 285.483 uV 14:34:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.654 uVs 14:34:05 Integrated Voltage Measurement... 14:34:14 Voltage Offset Correction: v_off_ini = 290.673 uV, v_off_fin = 292.919 uV 14:34:14 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 90.791 uVs 14:34:14 Integrated Voltage Measurement... 14:34:23 Voltage Offset Correction: v_off_ini = 288.429 uV, v_off_fin = 285.468 uV 14:34:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.683 uVs 14:34:23 Integrated Voltage Measurement... 14:34:32 Voltage Offset Correction: v_off_ini = 287.687 uV, v_off_fin = 288.249 uV 14:34:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.849 uVs 14:34:32 Integrated Voltage Measurement... 14:34:41 Voltage Offset Correction: v_off_ini = 282.835 uV, v_off_fin = 295.184 uV 14:34:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.370 uVs 14:34:41 Integrated Voltage Measurement... 14:34:50 Voltage Offset Correction: v_off_ini = 300.794 uV, v_off_fin = 284.041 uV 14:34:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.576 uVs 14:34:54 I1X Average and RMS of Measurements VT = -104.154 +- 5.357 uVs I1X = 20.832 +- 1.071 uTm 14:34:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:01 Integrated Voltage Measurement... 14:35:10 Voltage Offset Correction: v_off_ini = 282.896 uV, v_off_fin = 273.371 uV 14:35:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -180.219 uVs 14:35:10 Integrated Voltage Measurement... 14:35:19 Voltage Offset Correction: v_off_ini = 282.907 uV, v_off_fin = 303.296 uV 14:35:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.575 uVs 14:35:19 Integrated Voltage Measurement... 14:35:28 Voltage Offset Correction: v_off_ini = 301.261 uV, v_off_fin = 292.619 uV 14:35:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.728 uVs 14:35:28 Integrated Voltage Measurement... 14:35:37 Voltage Offset Correction: v_off_ini = 301.935 uV, v_off_fin = 306.345 uV 14:35:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.853 uVs 14:35:37 Integrated Voltage Measurement... 14:35:46 Voltage Offset Correction: v_off_ini = 295.843 uV, v_off_fin = 295.704 uV 14:35:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.694 uVs 14:35:46 Integrated Voltage Measurement... 14:35:55 Voltage Offset Correction: v_off_ini = 292.714 uV, v_off_fin = 299.804 uV 14:35:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.782 uVs 14:35:59 I1Y Average and RMS of Measurements VT = -191.975 +- 0.784 uVs I1Y = -38.396 +- 0.156 uTm 14:36:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:07 Integrated Voltage Measurement... 14:36:16 Voltage Offset Correction: v_off_ini = 296.115 uV, v_off_fin = 303.121 uV 14:36:16 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -105.990 uVs 14:36:16 Integrated Voltage Measurement... 14:36:25 Voltage Offset Correction: v_off_ini = 310.464 uV, v_off_fin = 316.461 uV 14:36:25 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 98.632 uVs 14:36:25 Integrated Voltage Measurement... 14:36:34 Voltage Offset Correction: v_off_ini = 282.335 uV, v_off_fin = 294.658 uV 14:36:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.463 uVs 14:36:34 Integrated Voltage Measurement... 14:36:43 Voltage Offset Correction: v_off_ini = 306.889 uV, v_off_fin = 313.176 uV 14:36:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.566 uVs 14:36:43 Integrated Voltage Measurement... 14:36:52 Voltage Offset Correction: v_off_ini = 305.157 uV, v_off_fin = 289.122 uV 14:36:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.929 uVs 14:36:52 Integrated Voltage Measurement... 14:37:01 Voltage Offset Correction: v_off_ini = 302.789 uV, v_off_fin = 308.867 uV 14:37:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.554 uVs 14:37:04 I2X Average and RMS of Measurements VT = -90.189 +- 8.620 uVs I2X = 8.297 +- 0.793 uTm^2 14:37:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:37:11 Integrated Voltage Measurement... 14:37:20 Voltage Offset Correction: v_off_ini = 308.937 uV, v_off_fin = 292.558 uV 14:37:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.370 uVs 14:37:20 Integrated Voltage Measurement... 14:37:29 Voltage Offset Correction: v_off_ini = 294.107 uV, v_off_fin = 295.212 uV 14:37:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.033 uVs 14:37:29 Integrated Voltage Measurement... 14:37:38 Voltage Offset Correction: v_off_ini = 284.999 uV, v_off_fin = 301.176 uV 14:37:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.678 uVs 14:37:38 Integrated Voltage Measurement... 14:37:47 Voltage Offset Correction: v_off_ini = 303.730 uV, v_off_fin = 310.372 uV 14:37:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.188 uVs 14:37:47 Integrated Voltage Measurement... 14:37:56 Voltage Offset Correction: v_off_ini = 297.514 uV, v_off_fin = 304.109 uV 14:37:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.959 uVs 14:37:56 Integrated Voltage Measurement... 14:38:05 Voltage Offset Correction: v_off_ini = 315.603 uV, v_off_fin = 307.810 uV 14:38:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.146 uVs 14:38:08 I2Y Average and RMS of Measurements VT = -199.229 +- 3.412 uVs I2Y = -18.329 +- 0.314 uTm^2 14:38:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:24 Integrated Voltage Measurement... 14:38:33 Voltage Offset Correction: v_off_ini = 298.870 uV, v_off_fin = 293.298 uV 14:38:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -105.470 uVs 14:38:33 Integrated Voltage Measurement... 14:38:42 Voltage Offset Correction: v_off_ini = 308.812 uV, v_off_fin = 305.705 uV 14:38:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.633 uVs 14:38:42 Integrated Voltage Measurement... 14:38:51 Voltage Offset Correction: v_off_ini = 313.712 uV, v_off_fin = 301.946 uV 14:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.670 uVs 14:38:51 Integrated Voltage Measurement... 14:39:00 Voltage Offset Correction: v_off_ini = 310.154 uV, v_off_fin = 302.660 uV 14:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.210 uVs 14:39:00 Integrated Voltage Measurement... 14:39:09 Voltage Offset Correction: v_off_ini = 309.331 uV, v_off_fin = 307.254 uV 14:39:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.540 uVs 14:39:09 Integrated Voltage Measurement... 14:39:18 Voltage Offset Correction: v_off_ini = 311.676 uV, v_off_fin = 297.075 uV 14:39:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.974 uVs 14:39:22 I1X Average and RMS of Measurements VT = -106.416 +- 1.185 uVs I1X = 21.285 +- 0.237 uTm 14:39:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:29 Integrated Voltage Measurement... 14:39:38 Voltage Offset Correction: v_off_ini = 313.324 uV, v_off_fin = 301.493 uV 14:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.005 uVs 14:39:38 Integrated Voltage Measurement... 14:39:47 Voltage Offset Correction: v_off_ini = 305.553 uV, v_off_fin = 319.286 uV 14:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.661 uVs 14:39:47 Integrated Voltage Measurement... 14:39:56 Voltage Offset Correction: v_off_ini = 318.635 uV, v_off_fin = 298.246 uV 14:39:56 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -205.285 uVs 14:39:56 Integrated Voltage Measurement... 14:40:05 Voltage Offset Correction: v_off_ini = 323.873 uV, v_off_fin = 325.415 uV 14:40:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.085 uVs 14:40:05 Integrated Voltage Measurement... 14:40:14 Voltage Offset Correction: v_off_ini = 321.278 uV, v_off_fin = 313.379 uV 14:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.541 uVs 14:40:14 Integrated Voltage Measurement... 14:40:23 Voltage Offset Correction: v_off_ini = 306.687 uV, v_off_fin = 330.436 uV 14:40:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.203 uVs 14:40:27 I1Y Average and RMS of Measurements VT = -197.463 +- 2.968 uVs I1Y = -39.493 +- 0.594 uTm 14:40:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:35 Integrated Voltage Measurement... 14:40:44 Voltage Offset Correction: v_off_ini = 324.740 uV, v_off_fin = 305.255 uV 14:40:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -115.873 uVs 14:40:44 Integrated Voltage Measurement... 14:40:53 Voltage Offset Correction: v_off_ini = 320.190 uV, v_off_fin = 332.977 uV 14:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.299 uVs 14:40:53 Integrated Voltage Measurement... 14:41:02 Voltage Offset Correction: v_off_ini = 323.615 uV, v_off_fin = 314.963 uV 14:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.275 uVs 14:41:02 Integrated Voltage Measurement... 14:41:11 Voltage Offset Correction: v_off_ini = 325.919 uV, v_off_fin = 333.744 uV 14:41:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.030 uVs 14:41:11 Integrated Voltage Measurement... 14:41:20 Voltage Offset Correction: v_off_ini = 327.046 uV, v_off_fin = 317.356 uV 14:41:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.164 uVs 14:41:20 Integrated Voltage Measurement... 14:41:29 Voltage Offset Correction: v_off_ini = 324.655 uV, v_off_fin = 347.515 uV 14:41:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.691 uVs 14:41:31 I2X Average and RMS of Measurements VT = -102.555 +- 6.081 uVs I2X = 9.435 +- 0.560 uTm^2 14:41:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:39 Integrated Voltage Measurement... 14:41:48 Voltage Offset Correction: v_off_ini = 330.134 uV, v_off_fin = 348.856 uV 14:41:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.330 uVs 14:41:48 Integrated Voltage Measurement... 14:41:57 Voltage Offset Correction: v_off_ini = 340.889 uV, v_off_fin = 343.077 uV 14:41:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.177 uVs 14:41:57 Integrated Voltage Measurement... 14:42:06 Voltage Offset Correction: v_off_ini = 338.851 uV, v_off_fin = 328.450 uV 14:42:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.943 uVs 14:42:06 Integrated Voltage Measurement... 14:42:15 Voltage Offset Correction: v_off_ini = 338.076 uV, v_off_fin = 325.520 uV 14:42:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.284 uVs 14:42:15 Integrated Voltage Measurement... 14:42:24 Voltage Offset Correction: v_off_ini = 333.547 uV, v_off_fin = 324.810 uV 14:42:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -183.084 uVs 14:42:24 Integrated Voltage Measurement... 14:42:33 Voltage Offset Correction: v_off_ini = 331.052 uV, v_off_fin = 328.916 uV 14:42:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.178 uVs 14:42:35 I2Y Average and RMS of Measurements VT = -191.166 +- 2.902 uVs I2Y = -17.588 +- 0.267 uTm^2 14:42:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:54 Integrated Voltage Measurement... 14:43:03 Voltage Offset Correction: v_off_ini = 343.648 uV, v_off_fin = 330.117 uV 14:43:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.023 uVs 14:43:03 Integrated Voltage Measurement... 14:43:12 Voltage Offset Correction: v_off_ini = 313.864 uV, v_off_fin = 323.026 uV 14:43:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.938 uVs 14:43:12 Integrated Voltage Measurement... 14:43:21 Voltage Offset Correction: v_off_ini = 315.874 uV, v_off_fin = 320.828 uV 14:43:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.008 uVs 14:43:21 Integrated Voltage Measurement... 14:43:30 Voltage Offset Correction: v_off_ini = 336.139 uV, v_off_fin = 332.705 uV 14:43:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.816 uVs 14:43:30 Integrated Voltage Measurement... 14:43:39 Voltage Offset Correction: v_off_ini = 316.892 uV, v_off_fin = 325.138 uV 14:43:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.357 uVs 14:43:39 Integrated Voltage Measurement... 14:43:48 Voltage Offset Correction: v_off_ini = 328.868 uV, v_off_fin = 328.464 uV 14:43:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 137.707 uVs 14:43:52 I1X Average and RMS of Measurements VT = -131.141 +- 9.597 uVs I1X = 26.229 +- 1.919 uTm 14:43:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:59 Integrated Voltage Measurement... 14:44:08 Voltage Offset Correction: v_off_ini = 329.974 uV, v_off_fin = 328.100 uV 14:44:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -186.438 uVs 14:44:08 Integrated Voltage Measurement... 14:44:17 Voltage Offset Correction: v_off_ini = 350.589 uV, v_off_fin = 356.296 uV 14:44:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 187.689 uVs 14:44:17 Integrated Voltage Measurement... 14:44:26 Voltage Offset Correction: v_off_ini = 338.953 uV, v_off_fin = 323.479 uV 14:44:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -210.568 uVs 14:44:26 Integrated Voltage Measurement... 14:44:35 Voltage Offset Correction: v_off_ini = 347.317 uV, v_off_fin = 345.514 uV 14:44:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.751 uVs 14:44:35 Integrated Voltage Measurement... 14:44:43 Voltage Offset Correction: v_off_ini = 332.403 uV, v_off_fin = 333.665 uV 14:44:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.005 uVs 14:44:44 Integrated Voltage Measurement... 14:44:52 Voltage Offset Correction: v_off_ini = 343.800 uV, v_off_fin = 351.797 uV 14:44:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.698 uVs 14:44:57 I1Y Average and RMS of Measurements VT = -189.691 +- 2.855 uVs I1Y = -37.938 +- 0.571 uTm 14:45:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:04 Integrated Voltage Measurement... 14:45:13 Voltage Offset Correction: v_off_ini = 354.095 uV, v_off_fin = 340.841 uV 14:45:13 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -152.385 uVs 14:45:13 Integrated Voltage Measurement... 14:45:22 Voltage Offset Correction: v_off_ini = 346.260 uV, v_off_fin = 353.326 uV 14:45:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.391 uVs 14:45:22 Integrated Voltage Measurement... 14:45:31 Voltage Offset Correction: v_off_ini = 339.626 uV, v_off_fin = 338.941 uV 14:45:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.246 uVs 14:45:31 Integrated Voltage Measurement... 14:45:40 Voltage Offset Correction: v_off_ini = 357.373 uV, v_off_fin = 370.796 uV 14:45:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 109.125 uVs 14:45:40 Integrated Voltage Measurement... 14:45:49 Voltage Offset Correction: v_off_ini = 345.833 uV, v_off_fin = 343.087 uV 14:45:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -128.991 uVs 14:45:50 Integrated Voltage Measurement... 14:45:58 Voltage Offset Correction: v_off_ini = 339.059 uV, v_off_fin = 356.616 uV 14:45:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 144.684 uVs 14:46:01 I2X Average and RMS of Measurements VT = -127.970 +- 14.381 uVs I2X = 11.773 +- 1.323 uTm^2 14:46:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:09 Integrated Voltage Measurement... 14:46:18 Voltage Offset Correction: v_off_ini = 351.652 uV, v_off_fin = 356.354 uV 14:46:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.779 uVs 14:46:18 Integrated Voltage Measurement... 14:46:27 Voltage Offset Correction: v_off_ini = 349.785 uV, v_off_fin = 347.279 uV 14:46:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.676 uVs 14:46:27 Integrated Voltage Measurement... 14:46:36 Voltage Offset Correction: v_off_ini = 355.304 uV, v_off_fin = 357.684 uV 14:46:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.397 uVs 14:46:36 Integrated Voltage Measurement... 14:46:45 Voltage Offset Correction: v_off_ini = 363.916 uV, v_off_fin = 354.822 uV 14:46:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.675 uVs 14:46:45 Integrated Voltage Measurement... 14:46:54 Voltage Offset Correction: v_off_ini = 348.853 uV, v_off_fin = 358.665 uV 14:46:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.767 uVs 14:46:54 Integrated Voltage Measurement... 14:47:03 Voltage Offset Correction: v_off_ini = 355.683 uV, v_off_fin = 362.597 uV 14:47:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.136 uVs 14:47:05 I2Y Average and RMS of Measurements VT = -198.405 +- 1.342 uVs I2Y = -18.253 +- 0.123 uTm^2 14:47:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:23 Integrated Voltage Measurement... 14:47:32 Voltage Offset Correction: v_off_ini = 364.123 uV, v_off_fin = 351.902 uV 14:47:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.264 uVs 14:47:32 Integrated Voltage Measurement... 14:47:41 Voltage Offset Correction: v_off_ini = 365.763 uV, v_off_fin = 362.343 uV 14:47:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.575 uVs 14:47:41 Integrated Voltage Measurement... 14:47:50 Voltage Offset Correction: v_off_ini = 359.719 uV, v_off_fin = 357.053 uV 14:47:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.580 uVs 14:47:50 Integrated Voltage Measurement... 14:47:59 Voltage Offset Correction: v_off_ini = 353.795 uV, v_off_fin = 366.877 uV 14:47:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 157.967 uVs 14:47:59 Integrated Voltage Measurement... 14:48:08 Voltage Offset Correction: v_off_ini = 360.815 uV, v_off_fin = 365.086 uV 14:48:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -134.623 uVs 14:48:08 Integrated Voltage Measurement... 14:48:17 Voltage Offset Correction: v_off_ini = 367.649 uV, v_off_fin = 366.688 uV 14:48:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 130.469 uVs 14:48:22 I1X Average and RMS of Measurements VT = -141.913 +- 9.405 uVs I1X = 28.386 +- 1.882 uTm 14:48:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:28 Integrated Voltage Measurement... 14:48:37 Voltage Offset Correction: v_off_ini = 375.590 uV, v_off_fin = 371.670 uV 14:48:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.023 uVs 14:48:37 Integrated Voltage Measurement... 14:48:46 Voltage Offset Correction: v_off_ini = 374.237 uV, v_off_fin = 395.914 uV 14:48:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.010 uVs 14:48:46 Integrated Voltage Measurement... 14:48:55 Voltage Offset Correction: v_off_ini = 387.515 uV, v_off_fin = 376.722 uV 14:48:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.527 uVs 14:48:55 Integrated Voltage Measurement... 14:49:04 Voltage Offset Correction: v_off_ini = 385.945 uV, v_off_fin = 407.932 uV 14:49:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.451 uVs 14:49:04 Integrated Voltage Measurement... 14:49:13 Voltage Offset Correction: v_off_ini = 391.184 uV, v_off_fin = 385.274 uV 14:49:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.975 uVs 14:49:13 Integrated Voltage Measurement... 14:49:22 Voltage Offset Correction: v_off_ini = 391.237 uV, v_off_fin = 401.004 uV 14:49:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.734 uVs 14:49:26 I1Y Average and RMS of Measurements VT = -204.287 +- 0.402 uVs I1Y = -40.857 +- 0.080 uTm 14:49:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:34 Integrated Voltage Measurement... 14:49:43 Voltage Offset Correction: v_off_ini = 400.151 uV, v_off_fin = 388.771 uV 14:49:43 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -151.549 uVs 14:49:43 Integrated Voltage Measurement... 14:49:52 Voltage Offset Correction: v_off_ini = 408.805 uV, v_off_fin = 410.917 uV 14:49:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.573 uVs 14:49:52 Integrated Voltage Measurement... 14:50:01 Voltage Offset Correction: v_off_ini = 390.059 uV, v_off_fin = 390.483 uV 14:50:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -122.106 uVs 14:50:01 Integrated Voltage Measurement... 14:50:10 Voltage Offset Correction: v_off_ini = 399.589 uV, v_off_fin = 406.205 uV 14:50:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 139.679 uVs 14:50:10 Integrated Voltage Measurement... 14:50:19 Voltage Offset Correction: v_off_ini = 411.508 uV, v_off_fin = 396.445 uV 14:50:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.850 uVs 14:50:19 Integrated Voltage Measurement... 14:50:28 Voltage Offset Correction: v_off_ini = 403.794 uV, v_off_fin = 417.144 uV 14:50:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.533 uVs 14:50:31 I2X Average and RMS of Measurements VT = -139.215 +- 5.887 uVs I2X = 12.808 +- 0.541 uTm^2 14:50:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:39 Integrated Voltage Measurement... 14:50:48 Voltage Offset Correction: v_off_ini = 409.096 uV, v_off_fin = 402.920 uV 14:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.321 uVs 14:50:48 Integrated Voltage Measurement... 14:50:57 Voltage Offset Correction: v_off_ini = 397.311 uV, v_off_fin = 407.808 uV 14:50:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.939 uVs 14:50:57 Integrated Voltage Measurement... 14:51:06 Voltage Offset Correction: v_off_ini = 402.725 uV, v_off_fin = 408.915 uV 14:51:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.544 uVs 14:51:06 Integrated Voltage Measurement... 14:51:15 Voltage Offset Correction: v_off_ini = 413.687 uV, v_off_fin = 412.733 uV 14:51:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.097 uVs 14:51:15 Integrated Voltage Measurement... 14:51:24 Voltage Offset Correction: v_off_ini = 407.028 uV, v_off_fin = 410.005 uV 14:51:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.691 uVs 14:51:24 Integrated Voltage Measurement... 14:51:33 Voltage Offset Correction: v_off_ini = 408.046 uV, v_off_fin = 412.345 uV 14:51:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.876 uVs 14:51:35 I2Y Average and RMS of Measurements VT = -205.911 +- 9.184 uVs I2Y = -18.944 +- 0.845 uTm^2 14:51:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:53 Integrated Voltage Measurement... 14:52:02 Voltage Offset Correction: v_off_ini = 425.824 uV, v_off_fin = 427.738 uV 14:52:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -166.306 uVs 14:52:03 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 424.862 uV, v_off_fin = 425.644 uV 14:52:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.835 uVs 14:52:12 Integrated Voltage Measurement... 14:52:21 Voltage Offset Correction: v_off_ini = 424.755 uV, v_off_fin = 424.300 uV 14:52:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -159.446 uVs 14:52:21 Integrated Voltage Measurement... 14:52:30 Voltage Offset Correction: v_off_ini = 420.718 uV, v_off_fin = 428.879 uV 14:52:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 130.331 uVs 14:52:30 Integrated Voltage Measurement... 14:52:39 Voltage Offset Correction: v_off_ini = 420.132 uV, v_off_fin = 424.211 uV 14:52:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -160.479 uVs 14:52:39 Integrated Voltage Measurement... 14:52:48 Voltage Offset Correction: v_off_ini = 422.479 uV, v_off_fin = 418.178 uV 14:52:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.601 uVs 14:52:52 I1X Average and RMS of Measurements VT = -147.500 +- 2.327 uVs I1X = 29.500 +- 0.465 uTm 14:52:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:59 Integrated Voltage Measurement... 14:53:08 Voltage Offset Correction: v_off_ini = 427.868 uV, v_off_fin = 415.041 uV 14:53:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.918 uVs 14:53:08 Integrated Voltage Measurement... 14:53:17 Voltage Offset Correction: v_off_ini = 422.086 uV, v_off_fin = 435.867 uV 14:53:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.768 uVs 14:53:17 Integrated Voltage Measurement... 14:53:26 Voltage Offset Correction: v_off_ini = 431.521 uV, v_off_fin = 423.805 uV 14:53:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.162 uVs 14:53:26 Integrated Voltage Measurement... 14:53:35 Voltage Offset Correction: v_off_ini = 436.366 uV, v_off_fin = 450.762 uV 14:53:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.608 uVs 14:53:35 Integrated Voltage Measurement... 14:53:44 Voltage Offset Correction: v_off_ini = 439.300 uV, v_off_fin = 421.588 uV 14:53:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.208 uVs 14:53:44 Integrated Voltage Measurement... 14:53:53 Voltage Offset Correction: v_off_ini = 439.417 uV, v_off_fin = 438.233 uV 14:53:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.354 uVs 14:53:57 I1Y Average and RMS of Measurements VT = -206.503 +- 4.289 uVs I1Y = -41.299 +- 0.858 uTm 14:54:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:04 Integrated Voltage Measurement... 14:54:13 Voltage Offset Correction: v_off_ini = 439.715 uV, v_off_fin = 424.313 uV 14:54:13 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -155.027 uVs 14:54:13 Integrated Voltage Measurement... 14:54:22 Voltage Offset Correction: v_off_ini = 422.803 uV, v_off_fin = 437.348 uV 14:54:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 130.905 uVs 14:54:23 Integrated Voltage Measurement... 14:54:32 Voltage Offset Correction: v_off_ini = 436.591 uV, v_off_fin = 421.005 uV 14:54:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.534 uVs 14:54:32 Integrated Voltage Measurement... 14:54:41 Voltage Offset Correction: v_off_ini = 430.410 uV, v_off_fin = 446.317 uV 14:54:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.657 uVs 14:54:41 Integrated Voltage Measurement... 14:54:50 Voltage Offset Correction: v_off_ini = 436.023 uV, v_off_fin = 423.899 uV 14:54:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.600 uVs 14:54:50 Integrated Voltage Measurement... 14:54:59 Voltage Offset Correction: v_off_ini = 437.562 uV, v_off_fin = 443.468 uV 14:54:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.121 uVs 14:55:01 I2X Average and RMS of Measurements VT = -140.974 +- 7.789 uVs I2X = 12.969 +- 0.717 uTm^2 14:55:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:09 Integrated Voltage Measurement... 14:55:18 Voltage Offset Correction: v_off_ini = 433.554 uV, v_off_fin = 431.961 uV 14:55:18 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -209.476 uVs 14:55:18 Integrated Voltage Measurement... 14:55:27 Voltage Offset Correction: v_off_ini = 448.598 uV, v_off_fin = 437.801 uV 14:55:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.356 uVs 14:55:27 Integrated Voltage Measurement... 14:55:36 Voltage Offset Correction: v_off_ini = 438.795 uV, v_off_fin = 432.871 uV 14:55:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.481 uVs 14:55:36 Integrated Voltage Measurement... 14:55:45 Voltage Offset Correction: v_off_ini = 422.820 uV, v_off_fin = 432.731 uV 14:55:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.023 uVs 14:55:45 Integrated Voltage Measurement... 14:55:54 Voltage Offset Correction: v_off_ini = 436.111 uV, v_off_fin = 440.938 uV 14:55:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.503 uVs 14:55:54 Integrated Voltage Measurement... 14:56:03 Voltage Offset Correction: v_off_ini = 445.199 uV, v_off_fin = 445.963 uV 14:56:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.523 uVs 14:56:05 I2Y Average and RMS of Measurements VT = -211.394 +- 3.621 uVs I2Y = -19.448 +- 0.333 uTm^2 14:56:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:24 Integrated Voltage Measurement... 14:56:33 Voltage Offset Correction: v_off_ini = 428.291 uV, v_off_fin = 430.101 uV 14:56:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -166.902 uVs 14:56:33 Integrated Voltage Measurement... 14:56:42 Voltage Offset Correction: v_off_ini = 429.486 uV, v_off_fin = 436.020 uV 14:56:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.250 uVs 14:56:42 Integrated Voltage Measurement... 14:56:51 Voltage Offset Correction: v_off_ini = 436.619 uV, v_off_fin = 429.527 uV 14:56:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.968 uVs 14:56:51 Integrated Voltage Measurement... 14:57:00 Voltage Offset Correction: v_off_ini = 433.137 uV, v_off_fin = 445.069 uV 14:57:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.778 uVs 14:57:00 Integrated Voltage Measurement... 14:57:09 Voltage Offset Correction: v_off_ini = 428.693 uV, v_off_fin = 439.941 uV 14:57:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.314 uVs 14:57:09 Integrated Voltage Measurement... 14:57:18 Voltage Offset Correction: v_off_ini = 439.863 uV, v_off_fin = 430.109 uV 14:57:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.640 uVs 14:57:22 I1X Average and RMS of Measurements VT = -143.809 +- 15.411 uVs I1X = 28.763 +- 3.083 uTm 14:57:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:29 Integrated Voltage Measurement... 14:57:38 Voltage Offset Correction: v_off_ini = 434.655 uV, v_off_fin = 425.607 uV 14:57:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -209.722 uVs 14:57:38 Integrated Voltage Measurement... 14:57:47 Voltage Offset Correction: v_off_ini = 433.602 uV, v_off_fin = 444.391 uV 14:57:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.807 uVs 14:57:47 Integrated Voltage Measurement... 14:57:56 Voltage Offset Correction: v_off_ini = 436.028 uV, v_off_fin = 432.577 uV 14:57:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.645 uVs 14:57:56 Integrated Voltage Measurement... 14:58:05 Voltage Offset Correction: v_off_ini = 448.776 uV, v_off_fin = 450.165 uV 14:58:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.914 uVs 14:58:05 Integrated Voltage Measurement... 14:58:14 Voltage Offset Correction: v_off_ini = 443.929 uV, v_off_fin = 430.148 uV 14:58:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.278 uVs 14:58:14 Integrated Voltage Measurement... 14:58:23 Voltage Offset Correction: v_off_ini = 445.632 uV, v_off_fin = 462.527 uV 14:58:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.627 uVs 14:58:27 I1Y Average and RMS of Measurements VT = -209.499 +- 0.619 uVs I1Y = -41.898 +- 0.126 uTm 14:58:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:35 Integrated Voltage Measurement... 14:58:44 Voltage Offset Correction: v_off_ini = 436.419 uV, v_off_fin = 421.369 uV 14:58:44 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -151.926 uVs 14:58:44 Integrated Voltage Measurement... 14:58:53 Voltage Offset Correction: v_off_ini = 445.312 uV, v_off_fin = 455.592 uV 14:58:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.887 uVs 14:58:53 Integrated Voltage Measurement... 14:59:02 Voltage Offset Correction: v_off_ini = 428.087 uV, v_off_fin = 432.260 uV 14:59:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.044 uVs 14:59:02 Integrated Voltage Measurement... 14:59:11 Voltage Offset Correction: v_off_ini = 426.221 uV, v_off_fin = 448.579 uV 14:59:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.884 uVs 14:59:11 Integrated Voltage Measurement... 14:59:20 Voltage Offset Correction: v_off_ini = 438.278 uV, v_off_fin = 429.374 uV 14:59:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -160.730 uVs 14:59:20 Integrated Voltage Measurement... 14:59:29 Voltage Offset Correction: v_off_ini = 438.621 uV, v_off_fin = 453.891 uV 14:59:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.112 uVs 14:59:31 I2X Average and RMS of Measurements VT = -142.764 +- 4.400 uVs I2X = 13.134 +- 0.405 uTm^2 14:59:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:39 Integrated Voltage Measurement... 14:59:48 Voltage Offset Correction: v_off_ini = 440.733 uV, v_off_fin = 441.855 uV 14:59:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.614 uVs 14:59:48 Integrated Voltage Measurement... 14:59:57 Voltage Offset Correction: v_off_ini = 453.154 uV, v_off_fin = 455.037 uV 14:59:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.589 uVs 14:59:57 Integrated Voltage Measurement... 15:00:06 Voltage Offset Correction: v_off_ini = 454.695 uV, v_off_fin = 454.044 uV 15:00:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.411 uVs 15:00:06 Integrated Voltage Measurement... 15:00:15 Voltage Offset Correction: v_off_ini = 447.583 uV, v_off_fin = 455.053 uV 15:00:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.413 uVs 15:00:15 Integrated Voltage Measurement... 15:00:24 Voltage Offset Correction: v_off_ini = 446.722 uV, v_off_fin = 452.699 uV 15:00:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.049 uVs 15:00:24 Integrated Voltage Measurement... 15:00:33 Voltage Offset Correction: v_off_ini = 449.364 uV, v_off_fin = 454.374 uV 15:00:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 222.758 uVs 15:00:36 I2Y Average and RMS of Measurements VT = -216.805 +- 9.373 uVs I2Y = -19.946 +- 0.862 uTm^2 15:00:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:00:54 Integrated Voltage Measurement... 15:01:03 Voltage Offset Correction: v_off_ini = 455.995 uV, v_off_fin = 450.065 uV 15:01:03 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -172.040 uVs 15:01:03 Integrated Voltage Measurement... 15:01:12 Voltage Offset Correction: v_off_ini = 433.840 uV, v_off_fin = 455.987 uV 15:01:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 151.334 uVs 15:01:12 Integrated Voltage Measurement... 15:01:21 Voltage Offset Correction: v_off_ini = 458.257 uV, v_off_fin = 455.717 uV 15:01:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -166.163 uVs 15:01:21 Integrated Voltage Measurement... 15:01:30 Voltage Offset Correction: v_off_ini = 443.579 uV, v_off_fin = 456.277 uV 15:01:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.276 uVs 15:01:30 Integrated Voltage Measurement... 15:01:39 Voltage Offset Correction: v_off_ini = 449.082 uV, v_off_fin = 458.572 uV 15:01:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.665 uVs 15:01:39 Integrated Voltage Measurement... 15:01:48 Voltage Offset Correction: v_off_ini = 457.672 uV, v_off_fin = 468.403 uV 15:01:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.408 uVs 15:01:52 I1X Average and RMS of Measurements VT = -158.481 +- 2.965 uVs I1X = 31.700 +- 0.596 uTm 15:01:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:59 Integrated Voltage Measurement... 15:02:08 Voltage Offset Correction: v_off_ini = 451.744 uV, v_off_fin = 437.477 uV 15:02:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.485 uVs 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 442.790 uV, v_off_fin = 463.316 uV 15:02:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.449 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 449.832 uV, v_off_fin = 451.565 uV 15:02:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.296 uVs 15:02:26 Integrated Voltage Measurement... 15:02:35 Voltage Offset Correction: v_off_ini = 480.229 uV, v_off_fin = 471.677 uV 15:02:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 218.576 uVs 15:02:35 Integrated Voltage Measurement... 15:02:44 Voltage Offset Correction: v_off_ini = 463.740 uV, v_off_fin = 457.375 uV 15:02:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.785 uVs 15:02:44 Integrated Voltage Measurement... 15:02:53 Voltage Offset Correction: v_off_ini = 462.108 uV, v_off_fin = 476.093 uV 15:02:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.970 uVs 15:02:57 I1Y Average and RMS of Measurements VT = -221.760 +- 5.218 uVs I1Y = -44.351 +- 1.043 uTm 15:03:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:05 Integrated Voltage Measurement... 15:03:14 Voltage Offset Correction: v_off_ini = 460.543 uV, v_off_fin = 444.136 uV 15:03:14 Integrated Voltage Measurement dXYus = -1.0003 mm, dXYds = 0.0000 mm dXY = -1.0003 mm VT = -165.119 uVs 15:03:14 Integrated Voltage Measurement... 15:03:23 Voltage Offset Correction: v_off_ini = 459.666 uV, v_off_fin = 469.752 uV 15:03:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.279 uVs 15:03:23 Integrated Voltage Measurement... 15:03:32 Voltage Offset Correction: v_off_ini = 455.988 uV, v_off_fin = 464.301 uV 15:03:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -144.270 uVs 15:03:32 Integrated Voltage Measurement... 15:03:41 Voltage Offset Correction: v_off_ini = 448.441 uV, v_off_fin = 473.423 uV 15:03:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.962 uVs 15:03:41 Integrated Voltage Measurement... 15:03:50 Voltage Offset Correction: v_off_ini = 456.711 uV, v_off_fin = 455.957 uV 15:03:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -151.758 uVs 15:03:50 Integrated Voltage Measurement... 15:03:59 Voltage Offset Correction: v_off_ini = 467.516 uV, v_off_fin = 473.654 uV 15:03:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 149.237 uVs 15:04:02 I2X Average and RMS of Measurements VT = -148.938 +- 1.104 uVs I2X = 13.702 +- 0.102 uTm^2 15:04:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:09 Integrated Voltage Measurement... 15:04:18 Voltage Offset Correction: v_off_ini = 475.690 uV, v_off_fin = 470.562 uV 15:04:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.934 uVs 15:04:19 Integrated Voltage Measurement... 15:04:27 Voltage Offset Correction: v_off_ini = 474.511 uV, v_off_fin = 481.662 uV 15:04:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.888 uVs 15:04:28 Integrated Voltage Measurement... 15:04:37 Voltage Offset Correction: v_off_ini = 475.286 uV, v_off_fin = 471.134 uV 15:04:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.254 uVs 15:04:37 Integrated Voltage Measurement... 15:04:46 Voltage Offset Correction: v_off_ini = 476.000 uV, v_off_fin = 475.382 uV 15:04:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.370 uVs 15:04:46 Integrated Voltage Measurement... 15:04:55 Voltage Offset Correction: v_off_ini = 476.588 uV, v_off_fin = 475.699 uV 15:04:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.714 uVs 15:04:55 Integrated Voltage Measurement... 15:05:04 Voltage Offset Correction: v_off_ini = 494.910 uV, v_off_fin = 484.107 uV 15:05:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.067 uVs 15:05:06 I2Y Average and RMS of Measurements VT = -221.205 +- 7.189 uVs I2Y = -20.351 +- 0.661 uTm^2 15:05:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:24 Integrated Voltage Measurement... 15:05:33 Voltage Offset Correction: v_off_ini = 485.099 uV, v_off_fin = 490.553 uV 15:05:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.774 uVs 15:05:33 Integrated Voltage Measurement... 15:05:42 Voltage Offset Correction: v_off_ini = 483.243 uV, v_off_fin = 490.761 uV 15:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.156 uVs 15:05:42 Integrated Voltage Measurement... 15:05:51 Voltage Offset Correction: v_off_ini = 506.772 uV, v_off_fin = 490.890 uV 15:05:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.437 uVs 15:05:52 Integrated Voltage Measurement... 15:06:00 Voltage Offset Correction: v_off_ini = 488.424 uV, v_off_fin = 497.292 uV 15:06:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.889 uVs 15:06:01 Integrated Voltage Measurement... 15:06:09 Voltage Offset Correction: v_off_ini = 489.567 uV, v_off_fin = 487.109 uV 15:06:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.044 uVs 15:06:10 Integrated Voltage Measurement... 15:06:18 Voltage Offset Correction: v_off_ini = 480.534 uV, v_off_fin = 480.386 uV 15:06:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 139.061 uVs 15:06:23 I1X Average and RMS of Measurements VT = -149.893 +- 4.282 uVs I1X = 29.980 +- 0.857 uTm 15:06:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:30 Integrated Voltage Measurement... 15:06:38 Voltage Offset Correction: v_off_ini = 474.989 uV, v_off_fin = 468.598 uV 15:06:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.656 uVs 15:06:39 Integrated Voltage Measurement... 15:06:47 Voltage Offset Correction: v_off_ini = 467.326 uV, v_off_fin = 491.375 uV 15:06:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 247.186 uVs 15:06:48 Integrated Voltage Measurement... 15:06:56 Voltage Offset Correction: v_off_ini = 480.052 uV, v_off_fin = 471.265 uV 15:06:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.247 uVs 15:06:57 Integrated Voltage Measurement... 15:07:06 Voltage Offset Correction: v_off_ini = 483.222 uV, v_off_fin = 486.661 uV 15:07:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.402 uVs 15:07:06 Integrated Voltage Measurement... 15:07:15 Voltage Offset Correction: v_off_ini = 482.320 uV, v_off_fin = 456.641 uV 15:07:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.276 uVs 15:07:15 Integrated Voltage Measurement... 15:07:24 Voltage Offset Correction: v_off_ini = 457.274 uV, v_off_fin = 476.025 uV 15:07:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.245 uVs 15:07:28 I1Y Average and RMS of Measurements VT = -223.835 +- 5.805 uVs I1Y = -44.766 +- 1.160 uTm 15:07:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:35 Integrated Voltage Measurement... 15:07:44 Voltage Offset Correction: v_off_ini = 452.416 uV, v_off_fin = 448.032 uV 15:07:45 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -149.176 uVs 15:07:45 Integrated Voltage Measurement... 15:07:54 Voltage Offset Correction: v_off_ini = 459.675 uV, v_off_fin = 466.336 uV 15:07:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.818 uVs 15:07:54 Integrated Voltage Measurement... 15:08:03 Voltage Offset Correction: v_off_ini = 459.381 uV, v_off_fin = 446.680 uV 15:08:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.279 uVs 15:08:03 Integrated Voltage Measurement... 15:08:12 Voltage Offset Correction: v_off_ini = 451.284 uV, v_off_fin = 478.080 uV 15:08:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 152.147 uVs 15:08:12 Integrated Voltage Measurement... 15:08:21 Voltage Offset Correction: v_off_ini = 468.585 uV, v_off_fin = 458.869 uV 15:08:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -167.994 uVs 15:08:21 Integrated Voltage Measurement... 15:08:30 Voltage Offset Correction: v_off_ini = 464.564 uV, v_off_fin = 470.629 uV 15:08:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.215 uVs 15:08:32 I2X Average and RMS of Measurements VT = -146.605 +- 2.969 uVs I2X = 13.487 +- 0.274 uTm^2 15:08:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:40 Integrated Voltage Measurement... 15:08:49 Voltage Offset Correction: v_off_ini = 446.442 uV, v_off_fin = 463.563 uV 15:08:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.565 uVs 15:08:49 Integrated Voltage Measurement... 15:08:58 Voltage Offset Correction: v_off_ini = 452.199 uV, v_off_fin = 454.889 uV 15:08:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.153 uVs 15:08:58 Integrated Voltage Measurement... 15:09:07 Voltage Offset Correction: v_off_ini = 452.173 uV, v_off_fin = 458.956 uV 15:09:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.746 uVs 15:09:07 Integrated Voltage Measurement... 15:09:16 Voltage Offset Correction: v_off_ini = 458.103 uV, v_off_fin = 460.934 uV 15:09:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.701 uVs 15:09:16 Integrated Voltage Measurement... 15:09:25 Voltage Offset Correction: v_off_ini = 454.090 uV, v_off_fin = 458.386 uV 15:09:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.537 uVs 15:09:25 Integrated Voltage Measurement... 15:09:34 Voltage Offset Correction: v_off_ini = 462.538 uV, v_off_fin = 462.517 uV 15:09:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.201 uVs 15:09:37 I2Y Average and RMS of Measurements VT = -219.317 +- 7.168 uVs I2Y = -20.177 +- 0.659 uTm^2 15:09:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:38 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm