SLAC Magnetic Measurements Date: 08-01-2025 Time: 09:33:11 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16351 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched Wire Run Number: 5 Measurement Device: Operator: YL Comment: 09:33:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:33:21 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:33:22 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:33:24 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:33:25 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:33:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:33:40 Integrated Voltage Measurement... 09:33:49 Voltage Offset Correction: v_off_ini = -50.914 uV, v_off_fin = -51.338 uV 09:33:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.938 uVs 09:33:49 Integrated Voltage Measurement... 09:33:58 Voltage Offset Correction: v_off_ini = -41.697 uV, v_off_fin = -49.364 uV 09:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.800 uVs 09:33:58 Integrated Voltage Measurement... 09:34:07 Voltage Offset Correction: v_off_ini = -43.364 uV, v_off_fin = -45.804 uV 09:34:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.810 uVs 09:34:07 Integrated Voltage Measurement... 09:34:16 Voltage Offset Correction: v_off_ini = -19.550 uV, v_off_fin = -15.024 uV 09:34:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.146 uVs 09:34:16 Integrated Voltage Measurement... 09:34:25 Voltage Offset Correction: v_off_ini = -15.598 uV, v_off_fin = -15.283 uV 09:34:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -127.832 uVs 09:34:25 Integrated Voltage Measurement... 09:34:34 Voltage Offset Correction: v_off_ini = -7.044 uV, v_off_fin = -16.641 uV 09:34:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 115.073 uVs 09:34:38 I1X Average and RMS of Measurements VT = -123.933 +- 2.234 uVs I1X = 24.788 +- 0.446 uTm 09:34:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:34:45 Integrated Voltage Measurement... 09:34:54 Voltage Offset Correction: v_off_ini = -8.213 uV, v_off_fin = -17.393 uV 09:34:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -355.840 uVs 09:34:54 Integrated Voltage Measurement... 09:35:03 Voltage Offset Correction: v_off_ini = 8.071 uV, v_off_fin = 25.202 uV 09:35:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 340.823 uVs 09:35:03 Integrated Voltage Measurement... 09:35:12 Voltage Offset Correction: v_off_ini = 7.265 uV, v_off_fin = 3.031 uV 09:35:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -360.068 uVs 09:35:12 Integrated Voltage Measurement... 09:35:21 Voltage Offset Correction: v_off_ini = 9.127 uV, v_off_fin = 27.770 uV 09:35:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 337.569 uVs 09:35:21 Integrated Voltage Measurement... 09:35:30 Voltage Offset Correction: v_off_ini = 14.152 uV, v_off_fin = 7.336 uV 09:35:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -330.986 uVs 09:35:30 Integrated Voltage Measurement... 09:35:39 Voltage Offset Correction: v_off_ini = 32.185 uV, v_off_fin = 39.867 uV 09:35:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 354.888 uVs 09:35:43 I1Y Average and RMS of Measurements VT = -346.696 +- 2.665 uVs I1Y = -69.343 +- 0.535 uTm 09:35:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:35:51 Integrated Voltage Measurement... 09:36:00 Voltage Offset Correction: v_off_ini = 22.119 uV, v_off_fin = 35.197 uV 09:36:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.548 uVs 09:36:00 Integrated Voltage Measurement... 09:36:09 Voltage Offset Correction: v_off_ini = 46.830 uV, v_off_fin = 52.801 uV 09:36:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.000 uVs 09:36:09 Integrated Voltage Measurement... 09:36:18 Voltage Offset Correction: v_off_ini = 51.895 uV, v_off_fin = 43.151 uV 09:36:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.816 uVs 09:36:18 Integrated Voltage Measurement... 09:36:27 Voltage Offset Correction: v_off_ini = 44.979 uV, v_off_fin = 66.557 uV 09:36:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.569 uVs 09:36:27 Integrated Voltage Measurement... 09:36:36 Voltage Offset Correction: v_off_ini = 58.458 uV, v_off_fin = 47.673 uV 09:36:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.797 uVs 09:36:36 Integrated Voltage Measurement... 09:36:45 Voltage Offset Correction: v_off_ini = 53.738 uV, v_off_fin = 73.416 uV 09:36:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.642 uVs 09:36:47 I2X Average and RMS of Measurements VT = -78.895 +- 4.685 uVs I2X = 7.258 +- 0.431 uTm^2 09:36:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:36:55 Integrated Voltage Measurement... 09:37:04 Voltage Offset Correction: v_off_ini = 72.874 uV, v_off_fin = 78.898 uV 09:37:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -434.163 uVs 09:37:04 Integrated Voltage Measurement... 09:37:13 Voltage Offset Correction: v_off_ini = 73.164 uV, v_off_fin = 76.928 uV 09:37:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 446.155 uVs 09:37:13 Integrated Voltage Measurement... 09:37:22 Voltage Offset Correction: v_off_ini = 68.006 uV, v_off_fin = 63.555 uV 09:37:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -447.683 uVs 09:37:22 Integrated Voltage Measurement... 09:37:31 Voltage Offset Correction: v_off_ini = 57.146 uV, v_off_fin = 62.289 uV 09:37:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 459.610 uVs 09:37:31 Integrated Voltage Measurement... 09:37:40 Voltage Offset Correction: v_off_ini = 63.504 uV, v_off_fin = 74.051 uV 09:37:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.026 uVs 09:37:40 Integrated Voltage Measurement... 09:37:49 Voltage Offset Correction: v_off_ini = 61.301 uV, v_off_fin = 80.537 uV 09:37:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 474.073 uVs 09:37:51 I2Y Average and RMS of Measurements VT = -449.785 +- 6.851 uVs I2Y = -41.382 +- 0.630 uTm^2 09:38:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:38:06 Integrated Voltage Measurement... 09:38:15 Voltage Offset Correction: v_off_ini = 93.638 uV, v_off_fin = 105.887 uV 09:38:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.427 uVs 09:38:15 Integrated Voltage Measurement... 09:38:24 Voltage Offset Correction: v_off_ini = 96.933 uV, v_off_fin = 96.400 uV 09:38:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.278 uVs 09:38:24 Integrated Voltage Measurement... 09:38:33 Voltage Offset Correction: v_off_ini = 63.877 uV, v_off_fin = 81.597 uV 09:38:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.070 uVs 09:38:33 Integrated Voltage Measurement... 09:38:42 Voltage Offset Correction: v_off_ini = 75.608 uV, v_off_fin = 84.549 uV 09:38:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.265 uVs 09:38:42 Integrated Voltage Measurement... 09:38:51 Voltage Offset Correction: v_off_ini = 96.069 uV, v_off_fin = 83.013 uV 09:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.950 uVs 09:38:51 Integrated Voltage Measurement... 09:39:00 Voltage Offset Correction: v_off_ini = 88.060 uV, v_off_fin = 100.972 uV 09:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.757 uVs 09:39:05 I1X Average and RMS of Measurements VT = -109.124 +- 6.876 uVs I1X = 21.825 +- 1.375 uTm 09:39:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:39:11 Integrated Voltage Measurement... 09:39:20 Voltage Offset Correction: v_off_ini = 109.888 uV, v_off_fin = 97.471 uV 09:39:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -340.679 uVs 09:39:20 Integrated Voltage Measurement... 09:39:29 Voltage Offset Correction: v_off_ini = 110.321 uV, v_off_fin = 134.356 uV 09:39:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 339.063 uVs 09:39:29 Integrated Voltage Measurement... 09:39:38 Voltage Offset Correction: v_off_ini = 110.544 uV, v_off_fin = 104.643 uV 09:39:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -331.921 uVs 09:39:38 Integrated Voltage Measurement... 09:39:47 Voltage Offset Correction: v_off_ini = 112.909 uV, v_off_fin = 132.859 uV 09:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 337.392 uVs 09:39:47 Integrated Voltage Measurement... 09:39:56 Voltage Offset Correction: v_off_ini = 122.233 uV, v_off_fin = 116.983 uV 09:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -350.805 uVs 09:39:56 Integrated Voltage Measurement... 09:40:05 Voltage Offset Correction: v_off_ini = 131.031 uV, v_off_fin = 146.873 uV 09:40:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 352.965 uVs 09:40:10 I1Y Average and RMS of Measurements VT = -342.138 +- 7.214 uVs I1Y = -68.425 +- 1.442 uTm 09:40:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:40:17 Integrated Voltage Measurement... 09:40:26 Voltage Offset Correction: v_off_ini = 125.364 uV, v_off_fin = 125.394 uV 09:40:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.366 uVs 09:40:26 Integrated Voltage Measurement... 09:40:35 Voltage Offset Correction: v_off_ini = 141.341 uV, v_off_fin = 150.516 uV 09:40:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.800 uVs 09:40:35 Integrated Voltage Measurement... 09:40:44 Voltage Offset Correction: v_off_ini = 134.716 uV, v_off_fin = 134.103 uV 09:40:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.464 uVs 09:40:44 Integrated Voltage Measurement... 09:40:53 Voltage Offset Correction: v_off_ini = 130.022 uV, v_off_fin = 139.777 uV 09:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.629 uVs 09:40:53 Integrated Voltage Measurement... 09:41:02 Voltage Offset Correction: v_off_ini = 135.902 uV, v_off_fin = 140.532 uV 09:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.734 uVs 09:41:02 Integrated Voltage Measurement... 09:41:11 Voltage Offset Correction: v_off_ini = 158.061 uV, v_off_fin = 152.718 uV 09:41:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.006 uVs 09:41:14 I2X Average and RMS of Measurements VT = -82.666 +- 8.357 uVs I2X = 7.605 +- 0.769 uTm^2 09:41:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:41:21 Integrated Voltage Measurement... 09:41:30 Voltage Offset Correction: v_off_ini = 140.816 uV, v_off_fin = 135.273 uV 09:41:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -445.950 uVs 09:41:30 Integrated Voltage Measurement... 09:41:39 Voltage Offset Correction: v_off_ini = 147.534 uV, v_off_fin = 135.576 uV 09:41:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 443.089 uVs 09:41:40 Integrated Voltage Measurement... 09:41:49 Voltage Offset Correction: v_off_ini = 131.757 uV, v_off_fin = 144.046 uV 09:41:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -439.979 uVs 09:41:49 Integrated Voltage Measurement... 09:41:58 Voltage Offset Correction: v_off_ini = 153.464 uV, v_off_fin = 151.657 uV 09:41:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 425.463 uVs 09:41:58 Integrated Voltage Measurement... 09:42:07 Voltage Offset Correction: v_off_ini = 158.121 uV, v_off_fin = 149.430 uV 09:42:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -437.913 uVs 09:42:07 Integrated Voltage Measurement... 09:42:16 Voltage Offset Correction: v_off_ini = 159.495 uV, v_off_fin = 154.112 uV 09:42:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 427.757 uVs 09:42:18 I2Y Average and RMS of Measurements VT = -436.692 +- 5.535 uVs I2Y = -40.176 +- 0.509 uTm^2