SLAC Magnetic Measurements Date: 08-01-2025 Time: 14:41:52 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16351 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 3 Measurement Device: Operator: YL Comment: Off Axis 14:42:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:02 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:42:04 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:42:05 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:42:07 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:42:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:42:50 Integrated Voltage Measurement... 14:42:59 Voltage Offset Correction: v_off_ini = 487.963 uV, v_off_fin = 468.931 uV 14:42:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.082 uVs 14:42:59 Integrated Voltage Measurement... 14:43:08 Voltage Offset Correction: v_off_ini = 451.846 uV, v_off_fin = 464.823 uV 14:43:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.142 uVs 14:43:08 Integrated Voltage Measurement... 14:43:17 Voltage Offset Correction: v_off_ini = 475.538 uV, v_off_fin = 479.569 uV 14:43:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.101 uVs 14:43:17 Integrated Voltage Measurement... 14:43:26 Voltage Offset Correction: v_off_ini = 477.891 uV, v_off_fin = 495.360 uV 14:43:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.690 uVs 14:43:26 Integrated Voltage Measurement... 14:43:35 Voltage Offset Correction: v_off_ini = 483.106 uV, v_off_fin = 493.126 uV 14:43:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.308 uVs 14:43:35 Integrated Voltage Measurement... 14:43:44 Voltage Offset Correction: v_off_ini = 494.787 uV, v_off_fin = 498.619 uV 14:43:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.321 uVs 14:43:48 I1X Average and RMS of Measurements VT = -121.274 +- 8.485 uVs I1X = 24.255 +- 1.697 uTm 14:43:50 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:43:54 Integrated Voltage Measurement... 14:44:03 Voltage Offset Correction: v_off_ini = 495.337 uV, v_off_fin = 468.660 uV 14:44:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.547 uVs 14:44:03 Integrated Voltage Measurement... 14:44:12 Voltage Offset Correction: v_off_ini = 485.954 uV, v_off_fin = 499.738 uV 14:44:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.200 uVs 14:44:12 Integrated Voltage Measurement... 14:44:21 Voltage Offset Correction: v_off_ini = 484.587 uV, v_off_fin = 475.899 uV 14:44:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.015 uVs 14:44:21 Integrated Voltage Measurement... 14:44:30 Voltage Offset Correction: v_off_ini = 486.216 uV, v_off_fin = 496.953 uV 14:44:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.894 uVs 14:44:30 Integrated Voltage Measurement... 14:44:39 Voltage Offset Correction: v_off_ini = 481.276 uV, v_off_fin = 485.007 uV 14:44:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.615 uVs 14:44:39 Integrated Voltage Measurement... 14:44:48 Voltage Offset Correction: v_off_ini = 485.347 uV, v_off_fin = 487.105 uV 14:44:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.002 uVs 14:44:52 I1Y Average and RMS of Measurements VT = -203.712 +- 6.008 uVs I1Y = -40.742 +- 1.202 uTm 14:44:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:45:00 Integrated Voltage Measurement... 14:45:09 Voltage Offset Correction: v_off_ini = 495.886 uV, v_off_fin = 491.885 uV 14:45:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -85.012 uVs 14:45:09 Integrated Voltage Measurement... 14:45:18 Voltage Offset Correction: v_off_ini = 490.482 uV, v_off_fin = 500.291 uV 14:45:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.794 uVs 14:45:18 Integrated Voltage Measurement... 14:45:27 Voltage Offset Correction: v_off_ini = 501.684 uV, v_off_fin = 496.612 uV 14:45:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.339 uVs 14:45:27 Integrated Voltage Measurement... 14:45:36 Voltage Offset Correction: v_off_ini = 496.930 uV, v_off_fin = 505.442 uV 14:45:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.063 uVs 14:45:36 Integrated Voltage Measurement... 14:45:45 Voltage Offset Correction: v_off_ini = 506.535 uV, v_off_fin = 495.188 uV 14:45:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -70.497 uVs 14:45:45 Integrated Voltage Measurement... 14:45:54 Voltage Offset Correction: v_off_ini = 512.741 uV, v_off_fin = 507.547 uV 14:45:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.960 uVs 14:45:56 I2X Average and RMS of Measurements VT = -87.944 +- 4.821 uVs I2X = 8.091 +- 0.444 uTm^2 14:46:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:46:04 Integrated Voltage Measurement... 14:46:13 Voltage Offset Correction: v_off_ini = 519.797 uV, v_off_fin = 523.549 uV 14:46:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.709 uVs 14:46:13 Integrated Voltage Measurement... 14:46:22 Voltage Offset Correction: v_off_ini = 534.250 uV, v_off_fin = 534.392 uV 14:46:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.199 uVs 14:46:22 Integrated Voltage Measurement... 14:46:31 Voltage Offset Correction: v_off_ini = 532.155 uV, v_off_fin = 544.282 uV 14:46:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.318 uVs 14:46:31 Integrated Voltage Measurement... 14:46:40 Voltage Offset Correction: v_off_ini = 529.801 uV, v_off_fin = 520.811 uV 14:46:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.949 uVs 14:46:40 Integrated Voltage Measurement... 14:46:49 Voltage Offset Correction: v_off_ini = 504.777 uV, v_off_fin = 516.802 uV 14:46:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.175 uVs 14:46:49 Integrated Voltage Measurement... 14:46:58 Voltage Offset Correction: v_off_ini = 511.051 uV, v_off_fin = 518.497 uV 14:46:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.262 uVs 14:47:01 I2Y Average and RMS of Measurements VT = -259.602 +- 1.708 uVs I2Y = -23.883 +- 0.157 uTm^2 14:47:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:47:09 Integrated Voltage Measurement... 14:47:18 Voltage Offset Correction: v_off_ini = 525.367 uV, v_off_fin = 522.418 uV 14:47:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.554 uVs 14:47:18 Integrated Voltage Measurement... 14:47:27 Voltage Offset Correction: v_off_ini = 513.059 uV, v_off_fin = 518.814 uV 14:47:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.984 uVs 14:47:27 Integrated Voltage Measurement... 14:47:36 Voltage Offset Correction: v_off_ini = 534.536 uV, v_off_fin = 532.784 uV 14:47:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -128.342 uVs 14:47:36 Integrated Voltage Measurement... 14:47:45 Voltage Offset Correction: v_off_ini = 532.513 uV, v_off_fin = 542.077 uV 14:47:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 104.131 uVs 14:47:46 Integrated Voltage Measurement... 14:47:54 Voltage Offset Correction: v_off_ini = 534.136 uV, v_off_fin = 537.600 uV 14:47:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.189 uVs 14:47:55 Integrated Voltage Measurement... 14:48:03 Voltage Offset Correction: v_off_ini = 543.911 uV, v_off_fin = 541.160 uV 14:48:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.459 uVs 14:48:08 I1X Average and RMS of Measurements VT = -113.777 +- 5.370 uVs I1X = 22.757 +- 1.074 uTm 14:48:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:48:14 Integrated Voltage Measurement... 14:48:23 Voltage Offset Correction: v_off_ini = 528.385 uV, v_off_fin = 529.514 uV 14:48:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.298 uVs 14:48:23 Integrated Voltage Measurement... 14:48:32 Voltage Offset Correction: v_off_ini = 526.982 uV, v_off_fin = 538.146 uV 14:48:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.170 uVs 14:48:32 Integrated Voltage Measurement... 14:48:41 Voltage Offset Correction: v_off_ini = 531.561 uV, v_off_fin = 524.288 uV 14:48:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.571 uVs 14:48:41 Integrated Voltage Measurement... 14:48:50 Voltage Offset Correction: v_off_ini = 544.718 uV, v_off_fin = 548.401 uV 14:48:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.063 uVs 14:48:50 Integrated Voltage Measurement... 14:48:59 Voltage Offset Correction: v_off_ini = 534.307 uV, v_off_fin = 539.186 uV 14:48:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.890 uVs 14:48:59 Integrated Voltage Measurement... 14:49:08 Voltage Offset Correction: v_off_ini = 550.172 uV, v_off_fin = 552.538 uV 14:49:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.598 uVs 14:49:13 I1Y Average and RMS of Measurements VT = -223.265 +- 5.672 uVs I1Y = -44.653 +- 1.134 uTm 14:49:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:49:20 Integrated Voltage Measurement... 14:49:29 Voltage Offset Correction: v_off_ini = 537.436 uV, v_off_fin = 523.925 uV 14:49:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -81.706 uVs 14:49:29 Integrated Voltage Measurement... 14:49:38 Voltage Offset Correction: v_off_ini = 532.557 uV, v_off_fin = 542.285 uV 14:49:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.838 uVs 14:49:38 Integrated Voltage Measurement... 14:49:47 Voltage Offset Correction: v_off_ini = 539.383 uV, v_off_fin = 546.985 uV 14:49:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -70.945 uVs 14:49:47 Integrated Voltage Measurement... 14:49:56 Voltage Offset Correction: v_off_ini = 554.779 uV, v_off_fin = 546.230 uV 14:49:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 60.357 uVs 14:49:57 Integrated Voltage Measurement... 14:50:06 Voltage Offset Correction: v_off_ini = 528.540 uV, v_off_fin = 512.848 uV 14:50:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.402 uVs 14:50:06 Integrated Voltage Measurement... 14:50:15 Voltage Offset Correction: v_off_ini = 536.750 uV, v_off_fin = 552.694 uV 14:50:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.899 uVs 14:50:17 I2X Average and RMS of Measurements VT = -76.691 +- 7.894 uVs I2X = 7.056 +- 0.726 uTm^2 14:50:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:50:25 Integrated Voltage Measurement... 14:50:34 Voltage Offset Correction: v_off_ini = 531.283 uV, v_off_fin = 539.511 uV 14:50:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.985 uVs 14:50:34 Integrated Voltage Measurement... 14:50:43 Voltage Offset Correction: v_off_ini = 538.149 uV, v_off_fin = 538.308 uV 14:50:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.267 uVs 14:50:43 Integrated Voltage Measurement... 14:50:52 Voltage Offset Correction: v_off_ini = 547.820 uV, v_off_fin = 544.082 uV 14:50:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.005 uVs 14:50:52 Integrated Voltage Measurement... 14:51:01 Voltage Offset Correction: v_off_ini = 541.427 uV, v_off_fin = 543.349 uV 14:51:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.031 uVs 14:51:01 Integrated Voltage Measurement... 14:51:10 Voltage Offset Correction: v_off_ini = 554.381 uV, v_off_fin = 550.271 uV 14:51:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.030 uVs 14:51:10 Integrated Voltage Measurement... 14:51:19 Voltage Offset Correction: v_off_ini = 564.416 uV, v_off_fin = 546.582 uV 14:51:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.648 uVs 14:51:21 I2Y Average and RMS of Measurements VT = -295.994 +- 5.063 uVs I2Y = -27.231 +- 0.466 uTm^2 14:51:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:51:30 Integrated Voltage Measurement... 14:51:39 Voltage Offset Correction: v_off_ini = 567.105 uV, v_off_fin = 566.453 uV 14:51:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.846 uVs 14:51:39 Integrated Voltage Measurement... 14:51:48 Voltage Offset Correction: v_off_ini = 566.901 uV, v_off_fin = 569.016 uV 14:51:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.714 uVs 14:51:48 Integrated Voltage Measurement... 14:51:57 Voltage Offset Correction: v_off_ini = 564.114 uV, v_off_fin = 575.903 uV 14:51:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -104.183 uVs 14:51:57 Integrated Voltage Measurement... 14:52:06 Voltage Offset Correction: v_off_ini = 565.550 uV, v_off_fin = 573.261 uV 14:52:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 133.937 uVs 14:52:06 Integrated Voltage Measurement... 14:52:15 Voltage Offset Correction: v_off_ini = 571.650 uV, v_off_fin = 580.255 uV 14:52:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -122.828 uVs 14:52:15 Integrated Voltage Measurement... 14:52:24 Voltage Offset Correction: v_off_ini = 575.692 uV, v_off_fin = 591.340 uV 14:52:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 103.307 uVs 14:52:29 I1X Average and RMS of Measurements VT = -114.969 +- 2.895 uVs I1X = 22.996 +- 0.580 uTm 14:52:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:35 Integrated Voltage Measurement... 14:52:44 Voltage Offset Correction: v_off_ini = 578.277 uV, v_off_fin = 568.137 uV 14:52:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.329 uVs 14:52:44 Integrated Voltage Measurement... 14:52:53 Voltage Offset Correction: v_off_ini = 568.395 uV, v_off_fin = 583.095 uV 14:52:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.448 uVs 14:52:53 Integrated Voltage Measurement... 14:53:02 Voltage Offset Correction: v_off_ini = 582.029 uV, v_off_fin = 585.350 uV 14:53:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.561 uVs 14:53:02 Integrated Voltage Measurement... 14:53:11 Voltage Offset Correction: v_off_ini = 605.645 uV, v_off_fin = 613.163 uV 14:53:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.704 uVs 14:53:11 Integrated Voltage Measurement... 14:53:20 Voltage Offset Correction: v_off_ini = 589.131 uV, v_off_fin = 590.296 uV 14:53:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.700 uVs 14:53:20 Integrated Voltage Measurement... 14:53:29 Voltage Offset Correction: v_off_ini = 609.185 uV, v_off_fin = 606.918 uV 14:53:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.453 uVs 14:53:34 I1Y Average and RMS of Measurements VT = -235.033 +- 6.097 uVs I1Y = -47.007 +- 1.219 uTm 14:53:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:41 Integrated Voltage Measurement... 14:53:50 Voltage Offset Correction: v_off_ini = 589.169 uV, v_off_fin = 595.655 uV 14:53:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -80.585 uVs 14:53:50 Integrated Voltage Measurement... 14:53:59 Voltage Offset Correction: v_off_ini = 592.127 uV, v_off_fin = 607.632 uV 14:53:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.796 uVs 14:54:00 Integrated Voltage Measurement... 14:54:09 Voltage Offset Correction: v_off_ini = 584.074 uV, v_off_fin = 578.489 uV 14:54:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.720 uVs 14:54:09 Integrated Voltage Measurement... 14:54:18 Voltage Offset Correction: v_off_ini = 593.246 uV, v_off_fin = 597.749 uV 14:54:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.526 uVs 14:54:18 Integrated Voltage Measurement... 14:54:27 Voltage Offset Correction: v_off_ini = 590.879 uV, v_off_fin = 581.872 uV 14:54:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.200 uVs 14:54:27 Integrated Voltage Measurement... 14:54:36 Voltage Offset Correction: v_off_ini = 594.016 uV, v_off_fin = 597.781 uV 14:54:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.470 uVs 14:54:38 I2X Average and RMS of Measurements VT = -74.216 +- 7.737 uVs I2X = 6.828 +- 0.712 uTm^2 14:54:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:46 Integrated Voltage Measurement... 14:54:55 Voltage Offset Correction: v_off_ini = 593.905 uV, v_off_fin = 573.568 uV 14:54:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.721 uVs 14:54:55 Integrated Voltage Measurement... 14:55:04 Voltage Offset Correction: v_off_ini = 595.163 uV, v_off_fin = 579.747 uV 14:55:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.375 uVs 14:55:04 Integrated Voltage Measurement... 14:55:13 Voltage Offset Correction: v_off_ini = 583.158 uV, v_off_fin = 577.125 uV 14:55:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.969 uVs 14:55:13 Integrated Voltage Measurement... 14:55:22 Voltage Offset Correction: v_off_ini = 577.077 uV, v_off_fin = 587.119 uV 14:55:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.787 uVs 14:55:22 Integrated Voltage Measurement... 14:55:31 Voltage Offset Correction: v_off_ini = 582.361 uV, v_off_fin = 579.894 uV 14:55:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.900 uVs 14:55:31 Integrated Voltage Measurement... 14:55:40 Voltage Offset Correction: v_off_ini = 592.819 uV, v_off_fin = 595.825 uV 14:55:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.052 uVs 14:55:43 I2Y Average and RMS of Measurements VT = -304.634 +- 2.676 uVs I2Y = -28.026 +- 0.246 uTm^2 14:55:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:55:51 Integrated Voltage Measurement... 14:56:00 Voltage Offset Correction: v_off_ini = 587.647 uV, v_off_fin = 592.653 uV 14:56:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -132.381 uVs 14:56:00 Integrated Voltage Measurement... 14:56:09 Voltage Offset Correction: v_off_ini = 578.551 uV, v_off_fin = 574.849 uV 14:56:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.811 uVs 14:56:09 Integrated Voltage Measurement... 14:56:18 Voltage Offset Correction: v_off_ini = 578.310 uV, v_off_fin = 566.656 uV 14:56:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -128.299 uVs 14:56:18 Integrated Voltage Measurement... 14:56:27 Voltage Offset Correction: v_off_ini = 571.474 uV, v_off_fin = 584.824 uV 14:56:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 108.832 uVs 14:56:28 Integrated Voltage Measurement... 14:56:36 Voltage Offset Correction: v_off_ini = 584.002 uV, v_off_fin = 583.081 uV 14:56:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.566 uVs 14:56:37 Integrated Voltage Measurement... 14:56:45 Voltage Offset Correction: v_off_ini = 573.393 uV, v_off_fin = 578.942 uV 14:56:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.528 uVs 14:56:50 I1X Average and RMS of Measurements VT = -123.570 +- 3.636 uVs I1X = 24.716 +- 0.727 uTm 14:56:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:56:57 Integrated Voltage Measurement... 14:57:05 Voltage Offset Correction: v_off_ini = 581.800 uV, v_off_fin = 584.197 uV 14:57:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.502 uVs 14:57:06 Integrated Voltage Measurement... 14:57:15 Voltage Offset Correction: v_off_ini = 588.192 uV, v_off_fin = 588.522 uV 14:57:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.679 uVs 14:57:15 Integrated Voltage Measurement... 14:57:24 Voltage Offset Correction: v_off_ini = 575.817 uV, v_off_fin = 570.647 uV 14:57:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.769 uVs 14:57:24 Integrated Voltage Measurement... 14:57:33 Voltage Offset Correction: v_off_ini = 567.937 uV, v_off_fin = 579.634 uV 14:57:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.302 uVs 14:57:33 Integrated Voltage Measurement... 14:57:42 Voltage Offset Correction: v_off_ini = 562.867 uV, v_off_fin = 554.177 uV 14:57:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.111 uVs 14:57:42 Integrated Voltage Measurement... 14:57:51 Voltage Offset Correction: v_off_ini = 569.017 uV, v_off_fin = 592.164 uV 14:57:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.222 uVs 14:57:55 I1Y Average and RMS of Measurements VT = -253.598 +- 6.365 uVs I1Y = -50.720 +- 1.273 uTm 14:58:00 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:58:03 Integrated Voltage Measurement... 14:58:12 Voltage Offset Correction: v_off_ini = 565.088 uV, v_off_fin = 561.092 uV 14:58:12 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -68.312 uVs 14:58:12 Integrated Voltage Measurement... 14:58:21 Voltage Offset Correction: v_off_ini = 559.084 uV, v_off_fin = 572.472 uV 14:58:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.051 uVs 14:58:21 Integrated Voltage Measurement... 14:58:30 Voltage Offset Correction: v_off_ini = 564.454 uV, v_off_fin = 544.665 uV 14:58:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.647 uVs 14:58:30 Integrated Voltage Measurement... 14:58:39 Voltage Offset Correction: v_off_ini = 567.711 uV, v_off_fin = 583.900 uV 14:58:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.273 uVs 14:58:39 Integrated Voltage Measurement... 14:58:48 Voltage Offset Correction: v_off_ini = 586.472 uV, v_off_fin = 571.592 uV 14:58:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -71.890 uVs 14:58:48 Integrated Voltage Measurement... 14:58:57 Voltage Offset Correction: v_off_ini = 574.556 uV, v_off_fin = 582.884 uV 14:58:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.066 uVs 14:58:59 I2X Average and RMS of Measurements VT = -81.706 +- 6.504 uVs I2X = 7.517 +- 0.599 uTm^2 14:59:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:59:07 Integrated Voltage Measurement... 14:59:16 Voltage Offset Correction: v_off_ini = 589.843 uV, v_off_fin = 579.226 uV 14:59:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.950 uVs 14:59:16 Integrated Voltage Measurement... 14:59:25 Voltage Offset Correction: v_off_ini = 567.467 uV, v_off_fin = 570.936 uV 14:59:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.275 uVs 14:59:25 Integrated Voltage Measurement... 14:59:34 Voltage Offset Correction: v_off_ini = 571.734 uV, v_off_fin = 570.651 uV 14:59:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.503 uVs 14:59:34 Integrated Voltage Measurement... 14:59:43 Voltage Offset Correction: v_off_ini = 574.035 uV, v_off_fin = 565.121 uV 14:59:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.942 uVs 14:59:43 Integrated Voltage Measurement... 14:59:52 Voltage Offset Correction: v_off_ini = 552.541 uV, v_off_fin = 566.449 uV 14:59:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.322 uVs 14:59:52 Integrated Voltage Measurement... 15:00:01 Voltage Offset Correction: v_off_ini = 550.261 uV, v_off_fin = 550.737 uV 15:00:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.102 uVs 15:00:04 I2Y Average and RMS of Measurements VT = -328.849 +- 6.299 uVs I2Y = -30.254 +- 0.579 uTm^2 15:00:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:00:12 Integrated Voltage Measurement... 15:00:21 Voltage Offset Correction: v_off_ini = 558.191 uV, v_off_fin = 543.457 uV 15:00:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.261 uVs 15:00:21 Integrated Voltage Measurement... 15:00:30 Voltage Offset Correction: v_off_ini = 554.596 uV, v_off_fin = 558.696 uV 15:00:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.037 uVs 15:00:30 Integrated Voltage Measurement... 15:00:39 Voltage Offset Correction: v_off_ini = 572.180 uV, v_off_fin = 551.815 uV 15:00:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -121.144 uVs 15:00:39 Integrated Voltage Measurement... 15:00:48 Voltage Offset Correction: v_off_ini = 552.665 uV, v_off_fin = 547.526 uV 15:00:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 128.659 uVs 15:00:49 Integrated Voltage Measurement... 15:00:57 Voltage Offset Correction: v_off_ini = 519.326 uV, v_off_fin = 532.473 uV 15:00:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.488 uVs 15:00:58 Integrated Voltage Measurement... 15:01:06 Voltage Offset Correction: v_off_ini = 530.057 uV, v_off_fin = 546.783 uV 15:01:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.736 uVs 15:01:11 I1X Average and RMS of Measurements VT = -128.888 +- 12.781 uVs I1X = 25.779 +- 2.556 uTm 15:01:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:01:18 Integrated Voltage Measurement... 15:01:26 Voltage Offset Correction: v_off_ini = 544.561 uV, v_off_fin = 533.002 uV 15:01:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.965 uVs 15:01:27 Integrated Voltage Measurement... 15:01:35 Voltage Offset Correction: v_off_ini = 529.933 uV, v_off_fin = 546.226 uV 15:01:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 248.612 uVs 15:01:36 Integrated Voltage Measurement... 15:01:44 Voltage Offset Correction: v_off_ini = 536.334 uV, v_off_fin = 526.381 uV 15:01:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.078 uVs 15:01:45 Integrated Voltage Measurement... 15:01:53 Voltage Offset Correction: v_off_ini = 543.359 uV, v_off_fin = 548.322 uV 15:01:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.685 uVs 15:01:54 Integrated Voltage Measurement... 15:02:02 Voltage Offset Correction: v_off_ini = 538.395 uV, v_off_fin = 517.960 uV 15:02:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.434 uVs 15:02:03 Integrated Voltage Measurement... 15:02:11 Voltage Offset Correction: v_off_ini = 552.654 uV, v_off_fin = 558.713 uV 15:02:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.863 uVs 15:02:16 I1Y Average and RMS of Measurements VT = -264.940 +- 5.816 uVs I1Y = -52.989 +- 1.163 uTm 15:02:21 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:02:23 Integrated Voltage Measurement... 15:02:32 Voltage Offset Correction: v_off_ini = 524.549 uV, v_off_fin = 525.390 uV 15:02:32 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -77.842 uVs 15:02:33 Integrated Voltage Measurement... 15:02:42 Voltage Offset Correction: v_off_ini = 533.536 uV, v_off_fin = 533.489 uV 15:02:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 71.030 uVs 15:02:42 Integrated Voltage Measurement... 15:02:51 Voltage Offset Correction: v_off_ini = 530.800 uV, v_off_fin = 534.589 uV 15:02:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -64.521 uVs 15:02:51 Integrated Voltage Measurement... 15:03:00 Voltage Offset Correction: v_off_ini = 534.742 uV, v_off_fin = 524.672 uV 15:03:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.461 uVs 15:03:00 Integrated Voltage Measurement... 15:03:09 Voltage Offset Correction: v_off_ini = 512.547 uV, v_off_fin = 511.974 uV 15:03:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -50.908 uVs 15:03:09 Integrated Voltage Measurement... 15:03:18 Voltage Offset Correction: v_off_ini = 526.185 uV, v_off_fin = 526.203 uV 15:03:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.307 uVs 15:03:20 I2X Average and RMS of Measurements VT = -71.678 +- 9.743 uVs I2X = 6.595 +- 0.897 uTm^2 15:03:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:03:28 Integrated Voltage Measurement... 15:03:37 Voltage Offset Correction: v_off_ini = 522.744 uV, v_off_fin = 511.428 uV 15:03:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.320 uVs 15:03:37 Integrated Voltage Measurement... 15:03:46 Voltage Offset Correction: v_off_ini = 534.802 uV, v_off_fin = 538.587 uV 15:03:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.158 uVs 15:03:46 Integrated Voltage Measurement... 15:03:55 Voltage Offset Correction: v_off_ini = 537.184 uV, v_off_fin = 533.654 uV 15:03:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.859 uVs 15:03:55 Integrated Voltage Measurement... 15:04:04 Voltage Offset Correction: v_off_ini = 543.933 uV, v_off_fin = 542.487 uV 15:04:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.043 uVs 15:04:04 Integrated Voltage Measurement... 15:04:13 Voltage Offset Correction: v_off_ini = 531.323 uV, v_off_fin = 535.654 uV 15:04:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.000 uVs 15:04:13 Integrated Voltage Measurement... 15:04:22 Voltage Offset Correction: v_off_ini = 539.681 uV, v_off_fin = 540.516 uV 15:04:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 351.623 uVs 15:04:24 I2Y Average and RMS of Measurements VT = -332.500 +- 7.702 uVs I2Y = -30.590 +- 0.709 uTm^2 15:04:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:04:36 Integrated Voltage Measurement... 15:04:45 Voltage Offset Correction: v_off_ini = 551.697 uV, v_off_fin = 556.508 uV 15:04:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -100.272 uVs 15:04:45 Integrated Voltage Measurement... 15:04:54 Voltage Offset Correction: v_off_ini = 557.811 uV, v_off_fin = 548.795 uV 15:04:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 150.019 uVs 15:04:54 Integrated Voltage Measurement... 15:05:03 Voltage Offset Correction: v_off_ini = 545.598 uV, v_off_fin = 546.045 uV 15:05:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.292 uVs 15:05:03 Integrated Voltage Measurement... 15:05:12 Voltage Offset Correction: v_off_ini = 550.906 uV, v_off_fin = 553.094 uV 15:05:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.439 uVs 15:05:12 Integrated Voltage Measurement... 15:05:21 Voltage Offset Correction: v_off_ini = 552.389 uV, v_off_fin = 546.891 uV 15:05:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.055 uVs 15:05:22 Integrated Voltage Measurement... 15:05:30 Voltage Offset Correction: v_off_ini = 546.095 uV, v_off_fin = 557.770 uV 15:05:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.821 uVs 15:05:35 I1X Average and RMS of Measurements VT = -126.650 +- 8.609 uVs I1X = 25.332 +- 1.722 uTm 15:05:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:05:41 Integrated Voltage Measurement... 15:05:50 Voltage Offset Correction: v_off_ini = 560.774 uV, v_off_fin = 565.469 uV 15:05:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.048 uVs 15:05:50 Integrated Voltage Measurement... 15:05:59 Voltage Offset Correction: v_off_ini = 563.295 uV, v_off_fin = 583.784 uV 15:05:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.028 uVs 15:06:00 Integrated Voltage Measurement... 15:06:08 Voltage Offset Correction: v_off_ini = 574.837 uV, v_off_fin = 570.043 uV 15:06:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.641 uVs 15:06:09 Integrated Voltage Measurement... 15:06:17 Voltage Offset Correction: v_off_ini = 573.391 uV, v_off_fin = 591.740 uV 15:06:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.453 uVs 15:06:18 Integrated Voltage Measurement... 15:06:26 Voltage Offset Correction: v_off_ini = 561.372 uV, v_off_fin = 561.188 uV 15:06:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.746 uVs 15:06:27 Integrated Voltage Measurement... 15:06:35 Voltage Offset Correction: v_off_ini = 573.846 uV, v_off_fin = 577.522 uV 15:06:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.700 uVs 15:06:40 I1Y Average and RMS of Measurements VT = -233.436 +- 6.961 uVs I1Y = -46.687 +- 1.392 uTm 15:06:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:06:45 Integrated Voltage Measurement... 15:06:54 Voltage Offset Correction: v_off_ini = 576.794 uV, v_off_fin = 575.220 uV 15:06:54 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -74.455 uVs 15:06:54 Integrated Voltage Measurement... 15:07:03 Voltage Offset Correction: v_off_ini = 570.751 uV, v_off_fin = 567.566 uV 15:07:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.859 uVs 15:07:03 Integrated Voltage Measurement... 15:07:12 Voltage Offset Correction: v_off_ini = 568.408 uV, v_off_fin = 558.386 uV 15:07:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.080 uVs 15:07:12 Integrated Voltage Measurement... 15:07:21 Voltage Offset Correction: v_off_ini = 567.978 uV, v_off_fin = 581.753 uV 15:07:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.099 uVs 15:07:21 Integrated Voltage Measurement... 15:07:30 Voltage Offset Correction: v_off_ini = 572.353 uV, v_off_fin = 562.029 uV 15:07:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.385 uVs 15:07:30 Integrated Voltage Measurement... 15:07:39 Voltage Offset Correction: v_off_ini = 566.430 uV, v_off_fin = 580.142 uV 15:07:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.656 uVs 15:07:41 I2X Average and RMS of Measurements VT = -83.756 +- 6.731 uVs I2X = 7.705 +- 0.620 uTm^2 15:07:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:07:47 Integrated Voltage Measurement... 15:07:56 Voltage Offset Correction: v_off_ini = 581.792 uV, v_off_fin = 578.503 uV 15:07:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.259 uVs 15:07:56 Integrated Voltage Measurement... 15:08:05 Voltage Offset Correction: v_off_ini = 601.442 uV, v_off_fin = 592.361 uV 15:08:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.867 uVs 15:08:05 Integrated Voltage Measurement... 15:08:14 Voltage Offset Correction: v_off_ini = 589.704 uV, v_off_fin = 582.825 uV 15:08:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.790 uVs 15:08:14 Integrated Voltage Measurement... 15:08:23 Voltage Offset Correction: v_off_ini = 581.268 uV, v_off_fin = 577.468 uV 15:08:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.807 uVs 15:08:23 Integrated Voltage Measurement... 15:08:32 Voltage Offset Correction: v_off_ini = 586.432 uV, v_off_fin = 585.415 uV 15:08:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.176 uVs 15:08:32 Integrated Voltage Measurement... 15:08:41 Voltage Offset Correction: v_off_ini = 576.638 uV, v_off_fin = 567.396 uV 15:08:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.497 uVs 15:08:43 I2Y Average and RMS of Measurements VT = -300.066 +- 3.062 uVs I2Y = -27.606 +- 0.282 uTm^2 15:08:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:08:51 Integrated Voltage Measurement... 15:09:00 Voltage Offset Correction: v_off_ini = 571.449 uV, v_off_fin = 580.226 uV 15:09:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -108.419 uVs 15:09:01 Integrated Voltage Measurement... 15:09:09 Voltage Offset Correction: v_off_ini = 585.626 uV, v_off_fin = 566.543 uV 15:09:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.209 uVs 15:09:10 Integrated Voltage Measurement... 15:09:18 Voltage Offset Correction: v_off_ini = 567.947 uV, v_off_fin = 575.007 uV 15:09:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.204 uVs 15:09:19 Integrated Voltage Measurement... 15:09:28 Voltage Offset Correction: v_off_ini = 579.159 uV, v_off_fin = 580.909 uV 15:09:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.483 uVs 15:09:28 Integrated Voltage Measurement... 15:09:37 Voltage Offset Correction: v_off_ini = 561.902 uV, v_off_fin = 563.744 uV 15:09:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.569 uVs 15:09:37 Integrated Voltage Measurement... 15:09:46 Voltage Offset Correction: v_off_ini = 567.144 uV, v_off_fin = 573.395 uV 15:09:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.386 uVs 15:09:50 I1X Average and RMS of Measurements VT = -119.378 +- 7.212 uVs I1X = 23.876 +- 1.442 uTm 15:09:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:09:57 Integrated Voltage Measurement... 15:10:06 Voltage Offset Correction: v_off_ini = 570.320 uV, v_off_fin = 557.560 uV 15:10:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.506 uVs 15:10:06 Integrated Voltage Measurement... 15:10:15 Voltage Offset Correction: v_off_ini = 582.023 uV, v_off_fin = 596.760 uV 15:10:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.021 uVs 15:10:15 Integrated Voltage Measurement... 15:10:24 Voltage Offset Correction: v_off_ini = 577.388 uV, v_off_fin = 559.066 uV 15:10:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -237.565 uVs 15:10:24 Integrated Voltage Measurement... 15:10:33 Voltage Offset Correction: v_off_ini = 571.997 uV, v_off_fin = 589.087 uV 15:10:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.115 uVs 15:10:33 Integrated Voltage Measurement... 15:10:42 Voltage Offset Correction: v_off_ini = 581.803 uV, v_off_fin = 576.839 uV 15:10:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.511 uVs 15:10:42 Integrated Voltage Measurement... 15:10:51 Voltage Offset Correction: v_off_ini = 587.158 uV, v_off_fin = 588.128 uV 15:10:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.144 uVs 15:10:55 I1Y Average and RMS of Measurements VT = -224.310 +- 11.011 uVs I1Y = -44.863 +- 2.203 uTm 15:10:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:11:00 Integrated Voltage Measurement... 15:11:09 Voltage Offset Correction: v_off_ini = 579.694 uV, v_off_fin = 572.594 uV 15:11:09 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -91.223 uVs 15:11:09 Integrated Voltage Measurement... 15:11:18 Voltage Offset Correction: v_off_ini = 600.330 uV, v_off_fin = 603.251 uV 15:11:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.838 uVs 15:11:18 Integrated Voltage Measurement... 15:11:27 Voltage Offset Correction: v_off_ini = 598.795 uV, v_off_fin = 592.802 uV 15:11:27 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.760 uVs 15:11:27 Integrated Voltage Measurement... 15:11:36 Voltage Offset Correction: v_off_ini = 611.241 uV, v_off_fin = 608.209 uV 15:11:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.430 uVs 15:11:36 Integrated Voltage Measurement... 15:11:45 Voltage Offset Correction: v_off_ini = 600.298 uV, v_off_fin = 589.382 uV 15:11:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -95.415 uVs 15:11:45 Integrated Voltage Measurement... 15:11:54 Voltage Offset Correction: v_off_ini = 589.518 uV, v_off_fin = 595.632 uV 15:11:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.958 uVs 15:11:57 I2X Average and RMS of Measurements VT = -87.437 +- 7.076 uVs I2X = 8.045 +- 0.651 uTm^2 15:11:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:12:02 Integrated Voltage Measurement... 15:12:11 Voltage Offset Correction: v_off_ini = 596.118 uV, v_off_fin = 583.839 uV 15:12:11 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -297.247 uVs 15:12:11 Integrated Voltage Measurement... 15:12:20 Voltage Offset Correction: v_off_ini = 600.363 uV, v_off_fin = 604.007 uV 15:12:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.791 uVs 15:12:20 Integrated Voltage Measurement... 15:12:29 Voltage Offset Correction: v_off_ini = 588.906 uV, v_off_fin = 590.118 uV 15:12:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.936 uVs 15:12:29 Integrated Voltage Measurement... 15:12:38 Voltage Offset Correction: v_off_ini = 600.147 uV, v_off_fin = 600.322 uV 15:12:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.545 uVs 15:12:38 Integrated Voltage Measurement... 15:12:47 Voltage Offset Correction: v_off_ini = 604.874 uV, v_off_fin = 599.741 uV 15:12:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.584 uVs 15:12:47 Integrated Voltage Measurement... 15:12:56 Voltage Offset Correction: v_off_ini = 602.149 uV, v_off_fin = 602.499 uV 15:12:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.510 uVs 15:12:58 I2Y Average and RMS of Measurements VT = -298.935 +- 3.607 uVs I2Y = -27.502 +- 0.332 uTm^2 15:13:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:07 Integrated Voltage Measurement... 15:13:16 Voltage Offset Correction: v_off_ini = 600.126 uV, v_off_fin = 606.196 uV 15:13:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.465 uVs 15:13:16 Integrated Voltage Measurement... 15:13:25 Voltage Offset Correction: v_off_ini = 599.634 uV, v_off_fin = 599.255 uV 15:13:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.549 uVs 15:13:25 Integrated Voltage Measurement... 15:13:34 Voltage Offset Correction: v_off_ini = 604.837 uV, v_off_fin = 603.757 uV 15:13:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.964 uVs 15:13:34 Integrated Voltage Measurement... 15:13:43 Voltage Offset Correction: v_off_ini = 609.739 uV, v_off_fin = 616.216 uV 15:13:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.490 uVs 15:13:43 Integrated Voltage Measurement... 15:13:52 Voltage Offset Correction: v_off_ini = 602.142 uV, v_off_fin = 597.829 uV 15:13:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -100.431 uVs 15:13:52 Integrated Voltage Measurement... 15:14:01 Voltage Offset Correction: v_off_ini = 612.704 uV, v_off_fin = 601.930 uV 15:14:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 104.431 uVs 15:14:05 I1X Average and RMS of Measurements VT = -115.055 +- 8.927 uVs I1X = 23.012 +- 1.784 uTm 15:14:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:12 Integrated Voltage Measurement... 15:14:21 Voltage Offset Correction: v_off_ini = 599.303 uV, v_off_fin = 610.242 uV 15:14:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.464 uVs 15:14:21 Integrated Voltage Measurement... 15:14:30 Voltage Offset Correction: v_off_ini = 609.316 uV, v_off_fin = 627.632 uV 15:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.603 uVs 15:14:30 Integrated Voltage Measurement... 15:14:39 Voltage Offset Correction: v_off_ini = 619.562 uV, v_off_fin = 604.132 uV 15:14:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.498 uVs 15:14:39 Integrated Voltage Measurement... 15:14:48 Voltage Offset Correction: v_off_ini = 600.476 uV, v_off_fin = 623.141 uV 15:14:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.218 uVs 15:14:48 Integrated Voltage Measurement... 15:14:57 Voltage Offset Correction: v_off_ini = 610.750 uV, v_off_fin = 590.869 uV 15:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.311 uVs 15:14:57 Integrated Voltage Measurement... 15:15:06 Voltage Offset Correction: v_off_ini = 619.596 uV, v_off_fin = 606.734 uV 15:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.924 uVs 15:15:10 I1Y Average and RMS of Measurements VT = -227.503 +- 2.955 uVs I1Y = -45.501 +- 0.591 uTm 15:15:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:15 Integrated Voltage Measurement... 15:15:24 Voltage Offset Correction: v_off_ini = 606.887 uV, v_off_fin = 578.395 uV 15:15:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.560 uVs 15:15:24 Integrated Voltage Measurement... 15:15:33 Voltage Offset Correction: v_off_ini = 586.747 uV, v_off_fin = 597.983 uV 15:15:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.487 uVs 15:15:33 Integrated Voltage Measurement... 15:15:42 Voltage Offset Correction: v_off_ini = 600.024 uV, v_off_fin = 596.413 uV 15:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.936 uVs 15:15:42 Integrated Voltage Measurement... 15:15:51 Voltage Offset Correction: v_off_ini = 603.871 uV, v_off_fin = 604.345 uV 15:15:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.278 uVs 15:15:51 Integrated Voltage Measurement... 15:16:00 Voltage Offset Correction: v_off_ini = 605.636 uV, v_off_fin = 597.020 uV 15:16:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.661 uVs 15:16:00 Integrated Voltage Measurement... 15:16:09 Voltage Offset Correction: v_off_ini = 625.355 uV, v_off_fin = 616.328 uV 15:16:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.271 uVs 15:16:12 I2X Average and RMS of Measurements VT = -79.532 +- 4.981 uVs I2X = 7.317 +- 0.458 uTm^2 15:16:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:17 Integrated Voltage Measurement... 15:16:26 Voltage Offset Correction: v_off_ini = 607.370 uV, v_off_fin = 609.388 uV 15:16:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.791 uVs 15:16:26 Integrated Voltage Measurement... 15:16:35 Voltage Offset Correction: v_off_ini = 610.523 uV, v_off_fin = 600.709 uV 15:16:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.402 uVs 15:16:35 Integrated Voltage Measurement... 15:16:44 Voltage Offset Correction: v_off_ini = 591.843 uV, v_off_fin = 598.049 uV 15:16:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.748 uVs 15:16:44 Integrated Voltage Measurement... 15:16:53 Voltage Offset Correction: v_off_ini = 606.882 uV, v_off_fin = 602.953 uV 15:16:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.073 uVs 15:16:53 Integrated Voltage Measurement... 15:17:02 Voltage Offset Correction: v_off_ini = 604.449 uV, v_off_fin = 600.983 uV 15:17:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.513 uVs 15:17:02 Integrated Voltage Measurement... 15:17:11 Voltage Offset Correction: v_off_ini = 600.680 uV, v_off_fin = 603.160 uV 15:17:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 299.808 uVs 15:17:13 I2Y Average and RMS of Measurements VT = -301.056 +- 3.969 uVs I2Y = -27.697 +- 0.365 uTm^2 15:17:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:17:22 Integrated Voltage Measurement... 15:17:31 Voltage Offset Correction: v_off_ini = 615.182 uV, v_off_fin = 605.231 uV 15:17:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -114.280 uVs 15:17:31 Integrated Voltage Measurement... 15:17:40 Voltage Offset Correction: v_off_ini = 609.139 uV, v_off_fin = 623.412 uV 15:17:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.081 uVs 15:17:40 Integrated Voltage Measurement... 15:17:49 Voltage Offset Correction: v_off_ini = 615.528 uV, v_off_fin = 607.210 uV 15:17:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.834 uVs 15:17:49 Integrated Voltage Measurement... 15:17:58 Voltage Offset Correction: v_off_ini = 600.359 uV, v_off_fin = 590.610 uV 15:17:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.156 uVs 15:17:58 Integrated Voltage Measurement... 15:18:07 Voltage Offset Correction: v_off_ini = 604.441 uV, v_off_fin = 606.995 uV 15:18:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.919 uVs 15:18:07 Integrated Voltage Measurement... 15:18:16 Voltage Offset Correction: v_off_ini = 613.991 uV, v_off_fin = 611.642 uV 15:18:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.127 uVs 15:18:20 I1X Average and RMS of Measurements VT = -98.566 +- 8.563 uVs I1X = 19.715 +- 1.714 uTm 15:18:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:18:27 Integrated Voltage Measurement... 15:18:36 Voltage Offset Correction: v_off_ini = 593.703 uV, v_off_fin = 579.759 uV 15:18:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.423 uVs 15:18:36 Integrated Voltage Measurement... 15:18:45 Voltage Offset Correction: v_off_ini = 588.342 uV, v_off_fin = 601.719 uV 15:18:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.025 uVs 15:18:45 Integrated Voltage Measurement... 15:18:54 Voltage Offset Correction: v_off_ini = 602.658 uV, v_off_fin = 577.275 uV 15:18:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.659 uVs 15:18:54 Integrated Voltage Measurement... 15:19:03 Voltage Offset Correction: v_off_ini = 605.408 uV, v_off_fin = 611.310 uV 15:19:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.604 uVs 15:19:03 Integrated Voltage Measurement... 15:19:12 Voltage Offset Correction: v_off_ini = 602.598 uV, v_off_fin = 592.866 uV 15:19:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.375 uVs 15:19:12 Integrated Voltage Measurement... 15:19:21 Voltage Offset Correction: v_off_ini = 605.372 uV, v_off_fin = 622.710 uV 15:19:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.030 uVs 15:19:25 I1Y Average and RMS of Measurements VT = -227.853 +- 5.061 uVs I1Y = -45.570 +- 1.012 uTm 15:19:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:19:30 Integrated Voltage Measurement... 15:19:39 Voltage Offset Correction: v_off_ini = 582.144 uV, v_off_fin = 597.781 uV 15:19:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.618 uVs 15:19:39 Integrated Voltage Measurement... 15:19:48 Voltage Offset Correction: v_off_ini = 614.721 uV, v_off_fin = 615.600 uV 15:19:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.631 uVs 15:19:48 Integrated Voltage Measurement... 15:19:57 Voltage Offset Correction: v_off_ini = 602.819 uV, v_off_fin = 588.639 uV 15:19:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.924 uVs 15:19:57 Integrated Voltage Measurement... 15:20:06 Voltage Offset Correction: v_off_ini = 603.486 uV, v_off_fin = 598.694 uV 15:20:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.117 uVs 15:20:06 Integrated Voltage Measurement... 15:20:15 Voltage Offset Correction: v_off_ini = 594.843 uV, v_off_fin = 600.135 uV 15:20:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.147 uVs 15:20:15 Integrated Voltage Measurement... 15:20:24 Voltage Offset Correction: v_off_ini = 609.161 uV, v_off_fin = 618.235 uV 15:20:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.036 uVs 15:20:27 I2X Average and RMS of Measurements VT = -64.579 +- 1.118 uVs I2X = 5.941 +- 0.103 uTm^2 15:20:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:20:32 Integrated Voltage Measurement... 15:20:41 Voltage Offset Correction: v_off_ini = 622.094 uV, v_off_fin = 621.309 uV 15:20:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.171 uVs 15:20:41 Integrated Voltage Measurement... 15:20:50 Voltage Offset Correction: v_off_ini = 606.402 uV, v_off_fin = 610.114 uV 15:20:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.679 uVs 15:20:50 Integrated Voltage Measurement... 15:20:59 Voltage Offset Correction: v_off_ini = 608.816 uV, v_off_fin = 606.406 uV 15:20:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.726 uVs 15:20:59 Integrated Voltage Measurement... 15:21:08 Voltage Offset Correction: v_off_ini = 624.868 uV, v_off_fin = 625.174 uV 15:21:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.665 uVs 15:21:08 Integrated Voltage Measurement... 15:21:17 Voltage Offset Correction: v_off_ini = 641.839 uV, v_off_fin = 629.551 uV 15:21:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.031 uVs 15:21:17 Integrated Voltage Measurement... 15:21:26 Voltage Offset Correction: v_off_ini = 617.151 uV, v_off_fin = 624.124 uV 15:21:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.968 uVs 15:21:29 I2Y Average and RMS of Measurements VT = -301.707 +- 3.455 uVs I2Y = -27.757 +- 0.318 uTm^2 15:21:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:21:37 Integrated Voltage Measurement... 15:21:46 Voltage Offset Correction: v_off_ini = 628.342 uV, v_off_fin = 632.430 uV 15:21:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4997 mm dXY = -0.4999 mm VT = -106.226 uVs 15:21:46 Integrated Voltage Measurement... 15:21:55 Voltage Offset Correction: v_off_ini = 628.561 uV, v_off_fin = 621.531 uV 15:21:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.361 uVs 15:21:55 Integrated Voltage Measurement... 15:22:04 Voltage Offset Correction: v_off_ini = 617.537 uV, v_off_fin = 621.962 uV 15:22:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.804 uVs 15:22:04 Integrated Voltage Measurement... 15:22:13 Voltage Offset Correction: v_off_ini = 635.641 uV, v_off_fin = 635.904 uV 15:22:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 97.205 uVs 15:22:13 Integrated Voltage Measurement... 15:22:22 Voltage Offset Correction: v_off_ini = 641.136 uV, v_off_fin = 636.020 uV 15:22:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.842 uVs 15:22:22 Integrated Voltage Measurement... 15:22:31 Voltage Offset Correction: v_off_ini = 642.296 uV, v_off_fin = 642.998 uV 15:22:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.038 uVs 15:22:35 I1X Average and RMS of Measurements VT = -88.413 +- 7.724 uVs I1X = 17.685 +- 1.546 uTm 15:22:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:22:42 Integrated Voltage Measurement... 15:22:51 Voltage Offset Correction: v_off_ini = 648.230 uV, v_off_fin = 626.968 uV 15:22:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.080 uVs 15:22:51 Integrated Voltage Measurement... 15:23:00 Voltage Offset Correction: v_off_ini = 634.981 uV, v_off_fin = 645.420 uV 15:23:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.275 uVs 15:23:00 Integrated Voltage Measurement... 15:23:09 Voltage Offset Correction: v_off_ini = 635.688 uV, v_off_fin = 616.088 uV 15:23:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.277 uVs 15:23:09 Integrated Voltage Measurement... 15:23:18 Voltage Offset Correction: v_off_ini = 623.122 uV, v_off_fin = 637.627 uV 15:23:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.166 uVs 15:23:18 Integrated Voltage Measurement... 15:23:27 Voltage Offset Correction: v_off_ini = 631.330 uV, v_off_fin = 635.016 uV 15:23:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.879 uVs 15:23:27 Integrated Voltage Measurement... 15:23:36 Voltage Offset Correction: v_off_ini = 628.288 uV, v_off_fin = 644.109 uV 15:23:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.253 uVs 15:23:40 I1Y Average and RMS of Measurements VT = -232.322 +- 1.948 uVs I1Y = -46.464 +- 0.389 uTm 15:23:43 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:23:45 Integrated Voltage Measurement... 15:23:54 Voltage Offset Correction: v_off_ini = 615.500 uV, v_off_fin = 616.532 uV 15:23:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.976 uVs 15:23:54 Integrated Voltage Measurement... 15:24:03 Voltage Offset Correction: v_off_ini = 631.587 uV, v_off_fin = 636.731 uV 15:24:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.594 uVs 15:24:03 Integrated Voltage Measurement... 15:24:12 Voltage Offset Correction: v_off_ini = 619.242 uV, v_off_fin = 621.558 uV 15:24:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.867 uVs 15:24:12 Integrated Voltage Measurement... 15:24:21 Voltage Offset Correction: v_off_ini = 615.352 uV, v_off_fin = 621.124 uV 15:24:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.088 uVs 15:24:22 Integrated Voltage Measurement... 15:24:31 Voltage Offset Correction: v_off_ini = 616.573 uV, v_off_fin = 610.722 uV 15:24:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.207 uVs 15:24:31 Integrated Voltage Measurement... 15:24:40 Voltage Offset Correction: v_off_ini = 603.430 uV, v_off_fin = 618.320 uV 15:24:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.871 uVs 15:24:42 I2X Average and RMS of Measurements VT = -53.767 +- 8.218 uVs I2X = 4.947 +- 0.756 uTm^2 15:24:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:24:47 Integrated Voltage Measurement... 15:24:56 Voltage Offset Correction: v_off_ini = 634.494 uV, v_off_fin = 622.417 uV 15:24:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.254 uVs 15:24:56 Integrated Voltage Measurement... 15:25:05 Voltage Offset Correction: v_off_ini = 619.991 uV, v_off_fin = 620.943 uV 15:25:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.902 uVs 15:25:05 Integrated Voltage Measurement... 15:25:14 Voltage Offset Correction: v_off_ini = 623.694 uV, v_off_fin = 629.699 uV 15:25:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.779 uVs 15:25:14 Integrated Voltage Measurement... 15:25:23 Voltage Offset Correction: v_off_ini = 629.945 uV, v_off_fin = 627.261 uV 15:25:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.458 uVs 15:25:23 Integrated Voltage Measurement... 15:25:32 Voltage Offset Correction: v_off_ini = 625.649 uV, v_off_fin = 623.004 uV 15:25:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.291 uVs 15:25:32 Integrated Voltage Measurement... 15:25:41 Voltage Offset Correction: v_off_ini = 626.488 uV, v_off_fin = 627.749 uV 15:25:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.019 uVs 15:25:44 I2Y Average and RMS of Measurements VT = -303.950 +- 1.010 uVs I2Y = -27.963 +- 0.093 uTm^2 15:26:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:26:04 Integrated Voltage Measurement... 15:26:13 Voltage Offset Correction: v_off_ini = 641.164 uV, v_off_fin = 642.086 uV 15:26:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.616 uVs 15:26:13 Integrated Voltage Measurement... 15:26:22 Voltage Offset Correction: v_off_ini = 661.986 uV, v_off_fin = 663.685 uV 15:26:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 103.577 uVs 15:26:22 Integrated Voltage Measurement... 15:26:31 Voltage Offset Correction: v_off_ini = 661.647 uV, v_off_fin = 658.955 uV 15:26:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.108 uVs 15:26:31 Integrated Voltage Measurement... 15:26:40 Voltage Offset Correction: v_off_ini = 651.310 uV, v_off_fin = 651.546 uV 15:26:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 110.720 uVs 15:26:40 Integrated Voltage Measurement... 15:26:49 Voltage Offset Correction: v_off_ini = 631.395 uV, v_off_fin = 653.457 uV 15:26:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -102.374 uVs 15:26:49 Integrated Voltage Measurement... 15:26:58 Voltage Offset Correction: v_off_ini = 659.924 uV, v_off_fin = 662.782 uV 15:26:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 96.476 uVs 15:27:02 I1X Average and RMS of Measurements VT = -105.645 +- 5.099 uVs I1X = 21.131 +- 1.020 uTm 15:27:05 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:27:09 Integrated Voltage Measurement... 15:27:18 Voltage Offset Correction: v_off_ini = 662.671 uV, v_off_fin = 654.715 uV 15:27:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.616 uVs 15:27:18 Integrated Voltage Measurement... 15:27:27 Voltage Offset Correction: v_off_ini = 656.843 uV, v_off_fin = 672.492 uV 15:27:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.737 uVs 15:27:27 Integrated Voltage Measurement... 15:27:36 Voltage Offset Correction: v_off_ini = 667.255 uV, v_off_fin = 656.155 uV 15:27:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.079 uVs 15:27:36 Integrated Voltage Measurement... 15:27:45 Voltage Offset Correction: v_off_ini = 668.773 uV, v_off_fin = 674.083 uV 15:27:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.032 uVs 15:27:45 Integrated Voltage Measurement... 15:27:54 Voltage Offset Correction: v_off_ini = 668.606 uV, v_off_fin = 659.433 uV 15:27:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.167 uVs 15:27:54 Integrated Voltage Measurement... 15:28:03 Voltage Offset Correction: v_off_ini = 687.564 uV, v_off_fin = 687.893 uV 15:28:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.926 uVs 15:28:07 I1Y Average and RMS of Measurements VT = -192.093 +- 1.138 uVs I1Y = -38.419 +- 0.228 uTm 15:28:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:28:15 Integrated Voltage Measurement... 15:28:24 Voltage Offset Correction: v_off_ini = 668.644 uV, v_off_fin = 663.619 uV 15:28:24 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -96.311 uVs 15:28:24 Integrated Voltage Measurement... 15:28:33 Voltage Offset Correction: v_off_ini = 680.869 uV, v_off_fin = 670.999 uV 15:28:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.011 uVs 15:28:33 Integrated Voltage Measurement... 15:28:42 Voltage Offset Correction: v_off_ini = 678.590 uV, v_off_fin = 673.058 uV 15:28:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.888 uVs 15:28:42 Integrated Voltage Measurement... 15:28:51 Voltage Offset Correction: v_off_ini = 657.989 uV, v_off_fin = 660.829 uV 15:28:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.688 uVs 15:28:51 Integrated Voltage Measurement... 15:29:00 Voltage Offset Correction: v_off_ini = 661.075 uV, v_off_fin = 662.892 uV 15:29:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.485 uVs 15:29:00 Integrated Voltage Measurement... 15:29:09 Voltage Offset Correction: v_off_ini = 647.219 uV, v_off_fin = 663.178 uV 15:29:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.715 uVs 15:29:12 I2X Average and RMS of Measurements VT = -96.516 +- 2.642 uVs I2X = 8.879 +- 0.243 uTm^2 15:29:17 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:29:19 Integrated Voltage Measurement... 15:29:28 Voltage Offset Correction: v_off_ini = 661.351 uV, v_off_fin = 654.853 uV 15:29:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.421 uVs 15:29:28 Integrated Voltage Measurement... 15:29:37 Voltage Offset Correction: v_off_ini = 653.973 uV, v_off_fin = 656.609 uV 15:29:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.201 uVs 15:29:38 Integrated Voltage Measurement... 15:29:46 Voltage Offset Correction: v_off_ini = 665.561 uV, v_off_fin = 653.341 uV 15:29:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.759 uVs 15:29:47 Integrated Voltage Measurement... 15:29:56 Voltage Offset Correction: v_off_ini = 648.395 uV, v_off_fin = 659.274 uV 15:29:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.791 uVs 15:29:56 Integrated Voltage Measurement... 15:30:05 Voltage Offset Correction: v_off_ini = 652.404 uV, v_off_fin = 660.516 uV 15:30:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.223 uVs 15:30:05 Integrated Voltage Measurement... 15:30:14 Voltage Offset Correction: v_off_ini = 663.398 uV, v_off_fin = 658.810 uV 15:30:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.228 uVs 15:30:16 I2Y Average and RMS of Measurements VT = -258.604 +- 3.048 uVs I2Y = -23.792 +- 0.280 uTm^2 15:30:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:30:25 Integrated Voltage Measurement... 15:30:34 Voltage Offset Correction: v_off_ini = 671.010 uV, v_off_fin = 668.379 uV 15:30:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.976 uVs 15:30:34 Integrated Voltage Measurement... 15:30:43 Voltage Offset Correction: v_off_ini = 677.962 uV, v_off_fin = 682.228 uV 15:30:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.944 uVs 15:30:43 Integrated Voltage Measurement... 15:30:52 Voltage Offset Correction: v_off_ini = 679.767 uV, v_off_fin = 673.135 uV 15:30:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -107.564 uVs 15:30:52 Integrated Voltage Measurement... 15:31:01 Voltage Offset Correction: v_off_ini = 681.368 uV, v_off_fin = 672.325 uV 15:31:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.905 uVs 15:31:01 Integrated Voltage Measurement... 15:31:10 Voltage Offset Correction: v_off_ini = 674.472 uV, v_off_fin = 685.711 uV 15:31:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.688 uVs 15:31:10 Integrated Voltage Measurement... 15:31:19 Voltage Offset Correction: v_off_ini = 674.165 uV, v_off_fin = 674.495 uV 15:31:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.038 uVs 15:31:23 I1X Average and RMS of Measurements VT = -109.686 +- 3.767 uVs I1X = 21.938 +- 0.752 uTm 15:31:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:31:30 Integrated Voltage Measurement... 15:31:39 Voltage Offset Correction: v_off_ini = 674.520 uV, v_off_fin = 663.785 uV 15:31:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.731 uVs 15:31:39 Integrated Voltage Measurement... 15:31:48 Voltage Offset Correction: v_off_ini = 684.087 uV, v_off_fin = 700.546 uV 15:31:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.144 uVs 15:31:48 Integrated Voltage Measurement... 15:31:57 Voltage Offset Correction: v_off_ini = 680.836 uV, v_off_fin = 676.310 uV 15:31:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.581 uVs 15:31:57 Integrated Voltage Measurement... 15:32:06 Voltage Offset Correction: v_off_ini = 675.261 uV, v_off_fin = 676.090 uV 15:32:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.204 uVs 15:32:06 Integrated Voltage Measurement... 15:32:15 Voltage Offset Correction: v_off_ini = 663.257 uV, v_off_fin = 646.091 uV 15:32:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.881 uVs 15:32:15 Integrated Voltage Measurement... 15:32:24 Voltage Offset Correction: v_off_ini = 671.258 uV, v_off_fin = 671.322 uV 15:32:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.512 uVs 15:32:28 I1Y Average and RMS of Measurements VT = -206.509 +- 4.326 uVs I1Y = -41.302 +- 0.865 uTm 15:32:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:32:36 Integrated Voltage Measurement... 15:32:45 Voltage Offset Correction: v_off_ini = 666.426 uV, v_off_fin = 663.215 uV 15:32:45 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -64.586 uVs 15:32:45 Integrated Voltage Measurement... 15:32:54 Voltage Offset Correction: v_off_ini = 672.080 uV, v_off_fin = 692.837 uV 15:32:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.102 uVs 15:32:54 Integrated Voltage Measurement... 15:33:03 Voltage Offset Correction: v_off_ini = 664.656 uV, v_off_fin = 667.072 uV 15:33:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.200 uVs 15:33:03 Integrated Voltage Measurement... 15:33:12 Voltage Offset Correction: v_off_ini = 657.319 uV, v_off_fin = 668.480 uV 15:33:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.332 uVs 15:33:12 Integrated Voltage Measurement... 15:33:21 Voltage Offset Correction: v_off_ini = 672.688 uV, v_off_fin = 670.444 uV 15:33:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.202 uVs 15:33:21 Integrated Voltage Measurement... 15:33:30 Voltage Offset Correction: v_off_ini = 676.179 uV, v_off_fin = 679.689 uV 15:33:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 75.457 uVs 15:33:33 I2X Average and RMS of Measurements VT = -82.980 +- 1.913 uVs I2X = 7.634 +- 0.176 uTm^2 15:33:38 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:33:40 Integrated Voltage Measurement... 15:33:49 Voltage Offset Correction: v_off_ini = 654.752 uV, v_off_fin = 657.580 uV 15:33:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.666 uVs 15:33:49 Integrated Voltage Measurement... 15:33:58 Voltage Offset Correction: v_off_ini = 654.140 uV, v_off_fin = 649.861 uV 15:33:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.191 uVs 15:33:58 Integrated Voltage Measurement... 15:34:07 Voltage Offset Correction: v_off_ini = 650.779 uV, v_off_fin = 624.710 uV 15:34:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.875 uVs 15:34:08 Integrated Voltage Measurement... 15:34:17 Voltage Offset Correction: v_off_ini = 634.285 uV, v_off_fin = 636.327 uV 15:34:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.272 uVs 15:34:17 Integrated Voltage Measurement... 15:34:26 Voltage Offset Correction: v_off_ini = 615.851 uV, v_off_fin = 609.083 uV 15:34:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.690 uVs 15:34:26 Integrated Voltage Measurement... 15:34:35 Voltage Offset Correction: v_off_ini = 616.154 uV, v_off_fin = 629.105 uV 15:34:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.202 uVs 15:34:37 I2Y Average and RMS of Measurements VT = -274.483 +- 3.255 uVs I2Y = -25.252 +- 0.299 uTm^2 15:34:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:46 Integrated Voltage Measurement... 15:34:55 Voltage Offset Correction: v_off_ini = 627.162 uV, v_off_fin = 624.760 uV 15:34:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -118.095 uVs 15:34:55 Integrated Voltage Measurement... 15:35:04 Voltage Offset Correction: v_off_ini = 631.501 uV, v_off_fin = 628.393 uV 15:35:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 117.390 uVs 15:35:04 Integrated Voltage Measurement... 15:35:13 Voltage Offset Correction: v_off_ini = 644.788 uV, v_off_fin = 622.961 uV 15:35:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.630 uVs 15:35:13 Integrated Voltage Measurement... 15:35:22 Voltage Offset Correction: v_off_ini = 624.950 uV, v_off_fin = 635.146 uV 15:35:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.200 uVs 15:35:22 Integrated Voltage Measurement... 15:35:31 Voltage Offset Correction: v_off_ini = 631.909 uV, v_off_fin = 633.485 uV 15:35:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.667 uVs 15:35:31 Integrated Voltage Measurement... 15:35:40 Voltage Offset Correction: v_off_ini = 633.309 uV, v_off_fin = 634.062 uV 15:35:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.368 uVs 15:35:44 I1X Average and RMS of Measurements VT = -111.225 +- 7.060 uVs I1X = 22.247 +- 1.413 uTm 15:35:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:51 Integrated Voltage Measurement... 15:36:00 Voltage Offset Correction: v_off_ini = 630.300 uV, v_off_fin = 629.355 uV 15:36:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.512 uVs 15:36:00 Integrated Voltage Measurement... 15:36:09 Voltage Offset Correction: v_off_ini = 635.744 uV, v_off_fin = 643.836 uV 15:36:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.324 uVs 15:36:09 Integrated Voltage Measurement... 15:36:18 Voltage Offset Correction: v_off_ini = 647.428 uV, v_off_fin = 635.762 uV 15:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.743 uVs 15:36:18 Integrated Voltage Measurement... 15:36:27 Voltage Offset Correction: v_off_ini = 642.450 uV, v_off_fin = 662.433 uV 15:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.396 uVs 15:36:27 Integrated Voltage Measurement... 15:36:36 Voltage Offset Correction: v_off_ini = 643.355 uV, v_off_fin = 629.951 uV 15:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.653 uVs 15:36:36 Integrated Voltage Measurement... 15:36:45 Voltage Offset Correction: v_off_ini = 637.649 uV, v_off_fin = 646.321 uV 15:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.704 uVs 15:36:49 I1Y Average and RMS of Measurements VT = -230.722 +- 4.003 uVs I1Y = -46.144 +- 0.801 uTm 15:36:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:57 Integrated Voltage Measurement... 15:37:06 Voltage Offset Correction: v_off_ini = 625.525 uV, v_off_fin = 612.503 uV 15:37:06 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -65.710 uVs 15:37:06 Integrated Voltage Measurement... 15:37:15 Voltage Offset Correction: v_off_ini = 622.893 uV, v_off_fin = 625.837 uV 15:37:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.308 uVs 15:37:15 Integrated Voltage Measurement... 15:37:24 Voltage Offset Correction: v_off_ini = 605.761 uV, v_off_fin = 612.882 uV 15:37:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.070 uVs 15:37:24 Integrated Voltage Measurement... 15:37:33 Voltage Offset Correction: v_off_ini = 623.347 uV, v_off_fin = 630.398 uV 15:37:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 57.925 uVs 15:37:33 Integrated Voltage Measurement... 15:37:42 Voltage Offset Correction: v_off_ini = 623.002 uV, v_off_fin = 616.272 uV 15:37:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.859 uVs 15:37:42 Integrated Voltage Measurement... 15:37:51 Voltage Offset Correction: v_off_ini = 618.671 uV, v_off_fin = 606.866 uV 15:37:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.882 uVs 15:37:54 I2X Average and RMS of Measurements VT = -68.792 +- 2.402 uVs I2X = 6.329 +- 0.221 uTm^2 15:37:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:38:01 Integrated Voltage Measurement... 15:38:10 Voltage Offset Correction: v_off_ini = 617.729 uV, v_off_fin = 627.313 uV 15:38:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.986 uVs 15:38:10 Integrated Voltage Measurement... 15:38:19 Voltage Offset Correction: v_off_ini = 618.363 uV, v_off_fin = 635.332 uV 15:38:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.489 uVs 15:38:19 Integrated Voltage Measurement... 15:38:28 Voltage Offset Correction: v_off_ini = 630.222 uV, v_off_fin = 618.003 uV 15:38:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.117 uVs 15:38:29 Integrated Voltage Measurement... 15:38:37 Voltage Offset Correction: v_off_ini = 638.961 uV, v_off_fin = 629.768 uV 15:38:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.251 uVs 15:38:38 Integrated Voltage Measurement... 15:38:47 Voltage Offset Correction: v_off_ini = 629.661 uV, v_off_fin = 621.955 uV 15:38:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.299 uVs 15:38:47 Integrated Voltage Measurement... 15:38:56 Voltage Offset Correction: v_off_ini = 621.607 uV, v_off_fin = 629.947 uV 15:38:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.442 uVs 15:38:58 I2Y Average and RMS of Measurements VT = -292.931 +- 1.451 uVs I2Y = -26.950 +- 0.134 uTm^2 15:39:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:39:07 Integrated Voltage Measurement... 15:39:16 Voltage Offset Correction: v_off_ini = 636.473 uV, v_off_fin = 629.850 uV 15:39:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.837 uVs 15:39:16 Integrated Voltage Measurement... 15:39:25 Voltage Offset Correction: v_off_ini = 617.923 uV, v_off_fin = 625.718 uV 15:39:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.411 uVs 15:39:25 Integrated Voltage Measurement... 15:39:34 Voltage Offset Correction: v_off_ini = 627.288 uV, v_off_fin = 625.991 uV 15:39:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.640 uVs 15:39:34 Integrated Voltage Measurement... 15:39:43 Voltage Offset Correction: v_off_ini = 630.766 uV, v_off_fin = 637.723 uV 15:39:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.039 uVs 15:39:43 Integrated Voltage Measurement... 15:39:52 Voltage Offset Correction: v_off_ini = 627.100 uV, v_off_fin = 645.211 uV 15:39:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.493 uVs 15:39:52 Integrated Voltage Measurement... 15:40:01 Voltage Offset Correction: v_off_ini = 639.681 uV, v_off_fin = 643.806 uV 15:40:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.388 uVs 15:40:05 I1X Average and RMS of Measurements VT = -112.801 +- 3.964 uVs I1X = 22.561 +- 0.792 uTm 15:40:08 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:40:12 Integrated Voltage Measurement... 15:40:21 Voltage Offset Correction: v_off_ini = 630.557 uV, v_off_fin = 629.486 uV 15:40:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -243.890 uVs 15:40:21 Integrated Voltage Measurement... 15:40:30 Voltage Offset Correction: v_off_ini = 628.833 uV, v_off_fin = 641.266 uV 15:40:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.595 uVs 15:40:30 Integrated Voltage Measurement... 15:40:39 Voltage Offset Correction: v_off_ini = 628.953 uV, v_off_fin = 629.665 uV 15:40:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.276 uVs 15:40:39 Integrated Voltage Measurement... 15:40:48 Voltage Offset Correction: v_off_ini = 632.723 uV, v_off_fin = 642.858 uV 15:40:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.558 uVs 15:40:48 Integrated Voltage Measurement... 15:40:57 Voltage Offset Correction: v_off_ini = 626.965 uV, v_off_fin = 615.209 uV 15:40:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.258 uVs 15:40:57 Integrated Voltage Measurement... 15:41:06 Voltage Offset Correction: v_off_ini = 628.804 uV, v_off_fin = 640.785 uV 15:41:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.303 uVs 15:41:10 I1Y Average and RMS of Measurements VT = -245.813 +- 5.921 uVs I1Y = -49.164 +- 1.184 uTm 15:41:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:41:18 Integrated Voltage Measurement... 15:41:27 Voltage Offset Correction: v_off_ini = 623.833 uV, v_off_fin = 643.630 uV 15:41:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -76.160 uVs 15:41:27 Integrated Voltage Measurement... 15:41:36 Voltage Offset Correction: v_off_ini = 638.723 uV, v_off_fin = 646.019 uV 15:41:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.457 uVs 15:41:36 Integrated Voltage Measurement... 15:41:45 Voltage Offset Correction: v_off_ini = 636.335 uV, v_off_fin = 644.287 uV 15:41:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -87.574 uVs 15:41:45 Integrated Voltage Measurement... 15:41:54 Voltage Offset Correction: v_off_ini = 644.644 uV, v_off_fin = 642.592 uV 15:41:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 83.476 uVs 15:41:54 Integrated Voltage Measurement... 15:42:03 Voltage Offset Correction: v_off_ini = 636.640 uV, v_off_fin = 641.912 uV 15:42:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.080 uVs 15:42:03 Integrated Voltage Measurement... 15:42:12 Voltage Offset Correction: v_off_ini = 642.495 uV, v_off_fin = 647.292 uV 15:42:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.593 uVs 15:42:15 I2X Average and RMS of Measurements VT = -79.890 +- 7.488 uVs I2X = 7.350 +- 0.689 uTm^2 15:42:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:42:22 Integrated Voltage Measurement... 15:42:31 Voltage Offset Correction: v_off_ini = 644.516 uV, v_off_fin = 641.264 uV 15:42:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.359 uVs 15:42:31 Integrated Voltage Measurement... 15:42:40 Voltage Offset Correction: v_off_ini = 640.540 uV, v_off_fin = 652.397 uV 15:42:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.525 uVs 15:42:40 Integrated Voltage Measurement... 15:42:49 Voltage Offset Correction: v_off_ini = 645.066 uV, v_off_fin = 647.204 uV 15:42:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.406 uVs 15:42:49 Integrated Voltage Measurement... 15:42:58 Voltage Offset Correction: v_off_ini = 638.154 uV, v_off_fin = 647.516 uV 15:42:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.510 uVs 15:42:59 Integrated Voltage Measurement... 15:43:08 Voltage Offset Correction: v_off_ini = 648.285 uV, v_off_fin = 651.658 uV 15:43:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.125 uVs 15:43:08 Integrated Voltage Measurement... 15:43:17 Voltage Offset Correction: v_off_ini = 646.321 uV, v_off_fin = 652.651 uV 15:43:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.425 uVs 15:43:19 I2Y Average and RMS of Measurements VT = -303.558 +- 6.433 uVs I2Y = -27.927 +- 0.592 uTm^2 15:43:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:43:28 Integrated Voltage Measurement... 15:43:37 Voltage Offset Correction: v_off_ini = 655.386 uV, v_off_fin = 642.008 uV 15:43:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.700 uVs 15:43:37 Integrated Voltage Measurement... 15:43:46 Voltage Offset Correction: v_off_ini = 638.298 uV, v_off_fin = 630.412 uV 15:43:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.493 uVs 15:43:46 Integrated Voltage Measurement... 15:43:55 Voltage Offset Correction: v_off_ini = 634.900 uV, v_off_fin = 640.078 uV 15:43:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.195 uVs 15:43:55 Integrated Voltage Measurement... 15:44:04 Voltage Offset Correction: v_off_ini = 644.448 uV, v_off_fin = 637.386 uV 15:44:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.289 uVs 15:44:04 Integrated Voltage Measurement... 15:44:13 Voltage Offset Correction: v_off_ini = 648.564 uV, v_off_fin = 628.584 uV 15:44:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.684 uVs 15:44:13 Integrated Voltage Measurement... 15:44:22 Voltage Offset Correction: v_off_ini = 645.122 uV, v_off_fin = 660.028 uV 15:44:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.499 uVs 15:44:26 I1X Average and RMS of Measurements VT = -110.810 +- 1.920 uVs I1X = 22.162 +- 0.383 uTm 15:44:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:44:33 Integrated Voltage Measurement... 15:44:42 Voltage Offset Correction: v_off_ini = 668.443 uV, v_off_fin = 657.499 uV 15:44:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.658 uVs 15:44:42 Integrated Voltage Measurement... 15:44:51 Voltage Offset Correction: v_off_ini = 658.489 uV, v_off_fin = 655.206 uV 15:44:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.156 uVs 15:44:51 Integrated Voltage Measurement... 15:45:00 Voltage Offset Correction: v_off_ini = 649.512 uV, v_off_fin = 643.950 uV 15:45:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.130 uVs 15:45:00 Integrated Voltage Measurement... 15:45:09 Voltage Offset Correction: v_off_ini = 642.064 uV, v_off_fin = 669.964 uV 15:45:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.657 uVs 15:45:09 Integrated Voltage Measurement... 15:45:18 Voltage Offset Correction: v_off_ini = 648.431 uV, v_off_fin = 639.941 uV 15:45:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.134 uVs 15:45:18 Integrated Voltage Measurement... 15:45:27 Voltage Offset Correction: v_off_ini = 670.947 uV, v_off_fin = 659.872 uV 15:45:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.206 uVs 15:45:31 I1Y Average and RMS of Measurements VT = -250.490 +- 2.562 uVs I1Y = -50.098 +- 0.512 uTm 15:45:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:45:39 Integrated Voltage Measurement... 15:45:48 Voltage Offset Correction: v_off_ini = 645.234 uV, v_off_fin = 649.051 uV 15:45:48 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -84.698 uVs 15:45:48 Integrated Voltage Measurement... 15:45:57 Voltage Offset Correction: v_off_ini = 657.459 uV, v_off_fin = 668.635 uV 15:45:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.259 uVs 15:45:57 Integrated Voltage Measurement... 15:46:06 Voltage Offset Correction: v_off_ini = 652.270 uV, v_off_fin = 660.273 uV 15:46:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.277 uVs 15:46:06 Integrated Voltage Measurement... 15:46:15 Voltage Offset Correction: v_off_ini = 675.010 uV, v_off_fin = 666.213 uV 15:46:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.662 uVs 15:46:15 Integrated Voltage Measurement... 15:46:24 Voltage Offset Correction: v_off_ini = 642.534 uV, v_off_fin = 652.849 uV 15:46:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.635 uVs 15:46:24 Integrated Voltage Measurement... 15:46:33 Voltage Offset Correction: v_off_ini = 677.166 uV, v_off_fin = 682.973 uV 15:46:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.355 uVs 15:46:36 I2X Average and RMS of Measurements VT = -65.481 +- 6.093 uVs I2X = 6.024 +- 0.560 uTm^2 15:46:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:46:43 Integrated Voltage Measurement... 15:46:52 Voltage Offset Correction: v_off_ini = 666.408 uV, v_off_fin = 669.184 uV 15:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.124 uVs 15:46:52 Integrated Voltage Measurement... 15:47:01 Voltage Offset Correction: v_off_ini = 670.802 uV, v_off_fin = 681.865 uV 15:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.438 uVs 15:47:01 Integrated Voltage Measurement... 15:47:10 Voltage Offset Correction: v_off_ini = 698.637 uV, v_off_fin = 679.708 uV 15:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.332 uVs 15:47:10 Integrated Voltage Measurement... 15:47:19 Voltage Offset Correction: v_off_ini = 672.271 uV, v_off_fin = 673.247 uV 15:47:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.093 uVs 15:47:20 Integrated Voltage Measurement... 15:47:29 Voltage Offset Correction: v_off_ini = 676.327 uV, v_off_fin = 672.442 uV 15:47:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.712 uVs 15:47:29 Integrated Voltage Measurement... 15:47:38 Voltage Offset Correction: v_off_ini = 670.852 uV, v_off_fin = 674.350 uV 15:47:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.109 uVs 15:47:40 I2Y Average and RMS of Measurements VT = -319.968 +- 3.889 uVs I2Y = -29.437 +- 0.358 uTm^2 15:47:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:47:52 Integrated Voltage Measurement... 15:48:01 Voltage Offset Correction: v_off_ini = 679.205 uV, v_off_fin = 669.742 uV 15:48:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -127.413 uVs 15:48:01 Integrated Voltage Measurement... 15:48:10 Voltage Offset Correction: v_off_ini = 683.183 uV, v_off_fin = 658.992 uV 15:48:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.770 uVs 15:48:10 Integrated Voltage Measurement... 15:48:19 Voltage Offset Correction: v_off_ini = 668.267 uV, v_off_fin = 675.070 uV 15:48:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.815 uVs 15:48:19 Integrated Voltage Measurement... 15:48:28 Voltage Offset Correction: v_off_ini = 679.104 uV, v_off_fin = 693.727 uV 15:48:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.255 uVs 15:48:28 Integrated Voltage Measurement... 15:48:37 Voltage Offset Correction: v_off_ini = 665.838 uV, v_off_fin = 676.102 uV 15:48:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.323 uVs 15:48:37 Integrated Voltage Measurement... 15:48:46 Voltage Offset Correction: v_off_ini = 692.563 uV, v_off_fin = 675.513 uV 15:48:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.551 uVs 15:48:50 I1X Average and RMS of Measurements VT = -125.688 +- 3.120 uVs I1X = 25.139 +- 0.623 uTm 15:48:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:48:57 Integrated Voltage Measurement... 15:49:06 Voltage Offset Correction: v_off_ini = 686.598 uV, v_off_fin = 670.310 uV 15:49:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.300 uVs 15:49:06 Integrated Voltage Measurement... 15:49:15 Voltage Offset Correction: v_off_ini = 670.506 uV, v_off_fin = 688.376 uV 15:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.408 uVs 15:49:15 Integrated Voltage Measurement... 15:49:24 Voltage Offset Correction: v_off_ini = 678.098 uV, v_off_fin = 668.316 uV 15:49:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.385 uVs 15:49:24 Integrated Voltage Measurement... 15:49:33 Voltage Offset Correction: v_off_ini = 663.547 uV, v_off_fin = 689.454 uV 15:49:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.179 uVs 15:49:33 Integrated Voltage Measurement... 15:49:42 Voltage Offset Correction: v_off_ini = 672.322 uV, v_off_fin = 653.470 uV 15:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.871 uVs 15:49:42 Integrated Voltage Measurement... 15:49:51 Voltage Offset Correction: v_off_ini = 669.899 uV, v_off_fin = 676.604 uV 15:49:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.497 uVs 15:49:55 I1Y Average and RMS of Measurements VT = -225.607 +- 5.700 uVs I1Y = -45.121 +- 1.140 uTm 15:49:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:50:01 Integrated Voltage Measurement... 15:50:10 Voltage Offset Correction: v_off_ini = 674.203 uV, v_off_fin = 671.747 uV 15:50:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.187 uVs 15:50:10 Integrated Voltage Measurement... 15:50:19 Voltage Offset Correction: v_off_ini = 674.138 uV, v_off_fin = 671.843 uV 15:50:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.568 uVs 15:50:19 Integrated Voltage Measurement... 15:50:28 Voltage Offset Correction: v_off_ini = 671.520 uV, v_off_fin = 660.402 uV 15:50:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.135 uVs 15:50:28 Integrated Voltage Measurement... 15:50:37 Voltage Offset Correction: v_off_ini = 685.145 uV, v_off_fin = 683.203 uV 15:50:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.845 uVs 15:50:37 Integrated Voltage Measurement... 15:50:46 Voltage Offset Correction: v_off_ini = 689.550 uV, v_off_fin = 672.494 uV 15:50:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.457 uVs 15:50:46 Integrated Voltage Measurement... 15:50:55 Voltage Offset Correction: v_off_ini = 685.391 uV, v_off_fin = 691.924 uV 15:50:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.495 uVs 15:50:57 I2X Average and RMS of Measurements VT = -92.448 +- 5.807 uVs I2X = 8.505 +- 0.534 uTm^2 15:51:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:51:02 Integrated Voltage Measurement... 15:51:11 Voltage Offset Correction: v_off_ini = 695.408 uV, v_off_fin = 692.777 uV 15:51:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.470 uVs 15:51:11 Integrated Voltage Measurement... 15:51:20 Voltage Offset Correction: v_off_ini = 709.795 uV, v_off_fin = 712.285 uV 15:51:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.583 uVs 15:51:20 Integrated Voltage Measurement... 15:51:29 Voltage Offset Correction: v_off_ini = 707.951 uV, v_off_fin = 704.101 uV 15:51:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.848 uVs 15:51:29 Integrated Voltage Measurement... 15:51:38 Voltage Offset Correction: v_off_ini = 696.050 uV, v_off_fin = 690.871 uV 15:51:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.652 uVs 15:51:38 Integrated Voltage Measurement... 15:51:47 Voltage Offset Correction: v_off_ini = 698.305 uV, v_off_fin = 698.393 uV 15:51:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.169 uVs 15:51:48 Integrated Voltage Measurement... 15:51:57 Voltage Offset Correction: v_off_ini = 705.170 uV, v_off_fin = 700.110 uV 15:51:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.000 uVs 15:51:59 I2Y Average and RMS of Measurements VT = -289.120 +- 3.385 uVs I2Y = -26.599 +- 0.311 uTm^2 15:52:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:52:07 Integrated Voltage Measurement... 15:52:16 Voltage Offset Correction: v_off_ini = 712.639 uV, v_off_fin = 711.103 uV 15:52:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -115.144 uVs 15:52:16 Integrated Voltage Measurement... 15:52:25 Voltage Offset Correction: v_off_ini = 714.929 uV, v_off_fin = 713.633 uV 15:52:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.685 uVs 15:52:25 Integrated Voltage Measurement... 15:52:34 Voltage Offset Correction: v_off_ini = 727.846 uV, v_off_fin = 725.986 uV 15:52:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -127.895 uVs 15:52:34 Integrated Voltage Measurement... 15:52:43 Voltage Offset Correction: v_off_ini = 740.315 uV, v_off_fin = 747.712 uV 15:52:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.823 uVs 15:52:43 Integrated Voltage Measurement... 15:52:52 Voltage Offset Correction: v_off_ini = 729.971 uV, v_off_fin = 727.411 uV 15:52:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.615 uVs 15:52:52 Integrated Voltage Measurement... 15:53:01 Voltage Offset Correction: v_off_ini = 730.991 uV, v_off_fin = 733.700 uV 15:53:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.530 uVs 15:53:06 I1X Average and RMS of Measurements VT = -116.616 +- 4.730 uVs I1X = 23.324 +- 0.946 uTm 15:53:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:53:12 Integrated Voltage Measurement... 15:53:21 Voltage Offset Correction: v_off_ini = 731.064 uV, v_off_fin = 718.479 uV 15:53:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -224.641 uVs 15:53:21 Integrated Voltage Measurement... 15:53:30 Voltage Offset Correction: v_off_ini = 717.934 uV, v_off_fin = 735.352 uV 15:53:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.904 uVs 15:53:30 Integrated Voltage Measurement... 15:53:39 Voltage Offset Correction: v_off_ini = 725.696 uV, v_off_fin = 719.343 uV 15:53:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.458 uVs 15:53:39 Integrated Voltage Measurement... 15:53:48 Voltage Offset Correction: v_off_ini = 718.657 uV, v_off_fin = 724.954 uV 15:53:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.614 uVs 15:53:48 Integrated Voltage Measurement... 15:53:57 Voltage Offset Correction: v_off_ini = 737.091 uV, v_off_fin = 732.076 uV 15:53:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.772 uVs 15:53:57 Integrated Voltage Measurement... 15:54:06 Voltage Offset Correction: v_off_ini = 730.627 uV, v_off_fin = 750.448 uV 15:54:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.569 uVs 15:54:11 I1Y Average and RMS of Measurements VT = -224.160 +- 5.824 uVs I1Y = -44.833 +- 1.165 uTm 15:54:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:54:16 Integrated Voltage Measurement... 15:54:25 Voltage Offset Correction: v_off_ini = 725.541 uV, v_off_fin = 705.007 uV 15:54:25 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -91.113 uVs 15:54:25 Integrated Voltage Measurement... 15:54:34 Voltage Offset Correction: v_off_ini = 706.263 uV, v_off_fin = 728.204 uV 15:54:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.944 uVs 15:54:34 Integrated Voltage Measurement... 15:54:43 Voltage Offset Correction: v_off_ini = 715.962 uV, v_off_fin = 716.943 uV 15:54:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.649 uVs 15:54:43 Integrated Voltage Measurement... 15:54:52 Voltage Offset Correction: v_off_ini = 720.437 uV, v_off_fin = 734.896 uV 15:54:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.014 uVs 15:54:52 Integrated Voltage Measurement... 15:55:01 Voltage Offset Correction: v_off_ini = 720.077 uV, v_off_fin = 700.615 uV 15:55:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.789 uVs 15:55:01 Integrated Voltage Measurement... 15:55:10 Voltage Offset Correction: v_off_ini = 719.563 uV, v_off_fin = 722.184 uV 15:55:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.562 uVs 15:55:12 I2X Average and RMS of Measurements VT = -88.345 +- 3.530 uVs I2X = 8.128 +- 0.325 uTm^2 15:55:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:55:18 Integrated Voltage Measurement... 15:55:27 Voltage Offset Correction: v_off_ini = 712.729 uV, v_off_fin = 717.274 uV 15:55:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.111 uVs 15:55:27 Integrated Voltage Measurement... 15:55:36 Voltage Offset Correction: v_off_ini = 723.299 uV, v_off_fin = 734.084 uV 15:55:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.143 uVs 15:55:36 Integrated Voltage Measurement... 15:55:45 Voltage Offset Correction: v_off_ini = 732.693 uV, v_off_fin = 730.165 uV 15:55:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.396 uVs 15:55:45 Integrated Voltage Measurement... 15:55:54 Voltage Offset Correction: v_off_ini = 713.951 uV, v_off_fin = 721.292 uV 15:55:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.943 uVs 15:55:54 Integrated Voltage Measurement... 15:56:03 Voltage Offset Correction: v_off_ini = 711.299 uV, v_off_fin = 710.190 uV 15:56:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.076 uVs 15:56:03 Integrated Voltage Measurement... 15:56:12 Voltage Offset Correction: v_off_ini = 719.749 uV, v_off_fin = 716.065 uV 15:56:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.579 uVs 15:56:14 I2Y Average and RMS of Measurements VT = -293.875 +- 8.660 uVs I2Y = -27.036 +- 0.797 uTm^2 15:56:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:23 Integrated Voltage Measurement... 15:56:32 Voltage Offset Correction: v_off_ini = 714.488 uV, v_off_fin = 703.311 uV 15:56:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -102.739 uVs 15:56:32 Integrated Voltage Measurement... 15:56:41 Voltage Offset Correction: v_off_ini = 701.988 uV, v_off_fin = 703.587 uV 15:56:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.971 uVs 15:56:41 Integrated Voltage Measurement... 15:56:50 Voltage Offset Correction: v_off_ini = 684.170 uV, v_off_fin = 692.136 uV 15:56:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.988 uVs 15:56:50 Integrated Voltage Measurement... 15:56:59 Voltage Offset Correction: v_off_ini = 701.903 uV, v_off_fin = 706.056 uV 15:56:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.188 uVs 15:56:59 Integrated Voltage Measurement... 15:57:08 Voltage Offset Correction: v_off_ini = 706.797 uV, v_off_fin = 692.987 uV 15:57:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.986 uVs 15:57:08 Integrated Voltage Measurement... 15:57:17 Voltage Offset Correction: v_off_ini = 706.695 uV, v_off_fin = 711.222 uV 15:57:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 119.375 uVs 15:57:21 I1X Average and RMS of Measurements VT = -109.541 +- 5.082 uVs I1X = 21.910 +- 1.015 uTm 15:57:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:28 Integrated Voltage Measurement... 15:57:37 Voltage Offset Correction: v_off_ini = 699.665 uV, v_off_fin = 680.858 uV 15:57:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.908 uVs 15:57:37 Integrated Voltage Measurement... 15:57:46 Voltage Offset Correction: v_off_ini = 699.662 uV, v_off_fin = 712.051 uV 15:57:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.350 uVs 15:57:46 Integrated Voltage Measurement... 15:57:55 Voltage Offset Correction: v_off_ini = 691.597 uV, v_off_fin = 681.643 uV 15:57:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.464 uVs 15:57:55 Integrated Voltage Measurement... 15:58:04 Voltage Offset Correction: v_off_ini = 690.646 uV, v_off_fin = 725.229 uV 15:58:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.524 uVs 15:58:04 Integrated Voltage Measurement... 15:58:13 Voltage Offset Correction: v_off_ini = 706.250 uV, v_off_fin = 696.169 uV 15:58:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.423 uVs 15:58:13 Integrated Voltage Measurement... 15:58:22 Voltage Offset Correction: v_off_ini = 712.197 uV, v_off_fin = 712.311 uV 15:58:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.797 uVs 15:58:26 I1Y Average and RMS of Measurements VT = -226.744 +- 1.043 uVs I1Y = -45.349 +- 0.209 uTm 15:58:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:58:31 Integrated Voltage Measurement... 15:58:40 Voltage Offset Correction: v_off_ini = 693.426 uV, v_off_fin = 685.153 uV 15:58:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.289 uVs 15:58:40 Integrated Voltage Measurement... 15:58:49 Voltage Offset Correction: v_off_ini = 692.930 uV, v_off_fin = 694.454 uV 15:58:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.495 uVs 15:58:49 Integrated Voltage Measurement... 15:58:58 Voltage Offset Correction: v_off_ini = 700.925 uV, v_off_fin = 678.976 uV 15:58:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.718 uVs 15:58:58 Integrated Voltage Measurement... 15:59:07 Voltage Offset Correction: v_off_ini = 700.927 uV, v_off_fin = 700.211 uV 15:59:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.803 uVs 15:59:07 Integrated Voltage Measurement... 15:59:16 Voltage Offset Correction: v_off_ini = 686.612 uV, v_off_fin = 676.700 uV 15:59:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.746 uVs 15:59:16 Integrated Voltage Measurement... 15:59:25 Voltage Offset Correction: v_off_ini = 693.276 uV, v_off_fin = 707.210 uV 15:59:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.171 uVs 15:59:28 I2X Average and RMS of Measurements VT = -82.870 +- 10.371 uVs I2X = 7.624 +- 0.954 uTm^2 15:59:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:59:33 Integrated Voltage Measurement... 15:59:42 Voltage Offset Correction: v_off_ini = 711.154 uV, v_off_fin = 703.411 uV 15:59:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.461 uVs 15:59:42 Integrated Voltage Measurement... 15:59:51 Voltage Offset Correction: v_off_ini = 711.530 uV, v_off_fin = 703.571 uV 15:59:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.666 uVs 15:59:51 Integrated Voltage Measurement... 16:00:00 Voltage Offset Correction: v_off_ini = 692.348 uV, v_off_fin = 697.799 uV 16:00:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.229 uVs 16:00:00 Integrated Voltage Measurement... 16:00:09 Voltage Offset Correction: v_off_ini = 698.749 uV, v_off_fin = 696.158 uV 16:00:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 289.756 uVs 16:00:09 Integrated Voltage Measurement... 16:00:18 Voltage Offset Correction: v_off_ini = 686.887 uV, v_off_fin = 679.079 uV 16:00:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.823 uVs 16:00:18 Integrated Voltage Measurement... 16:00:27 Voltage Offset Correction: v_off_ini = 680.638 uV, v_off_fin = 673.793 uV 16:00:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.231 uVs 16:00:29 I2Y Average and RMS of Measurements VT = -290.528 +- 7.953 uVs I2Y = -26.729 +- 0.732 uTm^2 16:00:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:00:38 Integrated Voltage Measurement... 16:00:47 Voltage Offset Correction: v_off_ini = 690.916 uV, v_off_fin = 687.305 uV 16:00:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -103.330 uVs 16:00:47 Integrated Voltage Measurement... 16:00:56 Voltage Offset Correction: v_off_ini = 684.406 uV, v_off_fin = 699.671 uV 16:00:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.922 uVs 16:00:56 Integrated Voltage Measurement... 16:01:05 Voltage Offset Correction: v_off_ini = 706.127 uV, v_off_fin = 702.969 uV 16:01:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.686 uVs 16:01:05 Integrated Voltage Measurement... 16:01:14 Voltage Offset Correction: v_off_ini = 703.717 uV, v_off_fin = 700.638 uV 16:01:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.394 uVs 16:01:14 Integrated Voltage Measurement... 16:01:23 Voltage Offset Correction: v_off_ini = 727.434 uV, v_off_fin = 709.513 uV 16:01:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.056 uVs 16:01:23 Integrated Voltage Measurement... 16:01:32 Voltage Offset Correction: v_off_ini = 718.495 uV, v_off_fin = 694.976 uV 16:01:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.200 uVs 16:01:36 I1X Average and RMS of Measurements VT = -100.765 +- 10.038 uVs I1X = 20.153 +- 2.008 uTm 16:01:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:01:43 Integrated Voltage Measurement... 16:01:52 Voltage Offset Correction: v_off_ini = 701.474 uV, v_off_fin = 691.015 uV 16:01:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -228.045 uVs 16:01:52 Integrated Voltage Measurement... 16:02:01 Voltage Offset Correction: v_off_ini = 700.039 uV, v_off_fin = 707.322 uV 16:02:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.683 uVs 16:02:01 Integrated Voltage Measurement... 16:02:10 Voltage Offset Correction: v_off_ini = 714.691 uV, v_off_fin = 695.787 uV 16:02:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.691 uVs 16:02:10 Integrated Voltage Measurement... 16:02:19 Voltage Offset Correction: v_off_ini = 704.955 uV, v_off_fin = 710.572 uV 16:02:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.773 uVs 16:02:19 Integrated Voltage Measurement... 16:02:28 Voltage Offset Correction: v_off_ini = 696.121 uV, v_off_fin = 691.882 uV 16:02:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.351 uVs 16:02:28 Integrated Voltage Measurement... 16:02:37 Voltage Offset Correction: v_off_ini = 704.444 uV, v_off_fin = 715.262 uV 16:02:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.694 uVs 16:02:41 I1Y Average and RMS of Measurements VT = -217.873 +- 6.112 uVs I1Y = -43.572 +- 1.221 uTm 16:02:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:02:46 Integrated Voltage Measurement... 16:02:55 Voltage Offset Correction: v_off_ini = 692.288 uV, v_off_fin = 694.510 uV 16:02:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.271 uVs 16:02:55 Integrated Voltage Measurement... 16:03:04 Voltage Offset Correction: v_off_ini = 694.297 uV, v_off_fin = 698.628 uV 16:03:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.414 uVs 16:03:04 Integrated Voltage Measurement... 16:03:13 Voltage Offset Correction: v_off_ini = 700.090 uV, v_off_fin = 687.751 uV 16:03:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.953 uVs 16:03:13 Integrated Voltage Measurement... 16:03:22 Voltage Offset Correction: v_off_ini = 687.012 uV, v_off_fin = 702.864 uV 16:03:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.605 uVs 16:03:22 Integrated Voltage Measurement... 16:03:31 Voltage Offset Correction: v_off_ini = 678.727 uV, v_off_fin = 682.085 uV 16:03:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.854 uVs 16:03:31 Integrated Voltage Measurement... 16:03:40 Voltage Offset Correction: v_off_ini = 681.837 uV, v_off_fin = 698.220 uV 16:03:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 59.134 uVs 16:03:43 I2X Average and RMS of Measurements VT = -67.705 +- 6.591 uVs I2X = 6.229 +- 0.606 uTm^2 16:03:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:03:48 Integrated Voltage Measurement... 16:03:57 Voltage Offset Correction: v_off_ini = 668.690 uV, v_off_fin = 673.821 uV 16:03:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.833 uVs 16:03:57 Integrated Voltage Measurement... 16:04:06 Voltage Offset Correction: v_off_ini = 680.585 uV, v_off_fin = 687.098 uV 16:04:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.917 uVs 16:04:06 Integrated Voltage Measurement... 16:04:15 Voltage Offset Correction: v_off_ini = 692.489 uV, v_off_fin = 691.879 uV 16:04:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.881 uVs 16:04:15 Integrated Voltage Measurement... 16:04:24 Voltage Offset Correction: v_off_ini = 686.759 uV, v_off_fin = 688.631 uV 16:04:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.412 uVs 16:04:24 Integrated Voltage Measurement... 16:04:33 Voltage Offset Correction: v_off_ini = 682.905 uV, v_off_fin = 682.646 uV 16:04:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.169 uVs 16:04:33 Integrated Voltage Measurement... 16:04:42 Voltage Offset Correction: v_off_ini = 669.387 uV, v_off_fin = 675.220 uV 16:04:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.223 uVs 16:04:44 I2Y Average and RMS of Measurements VT = -296.573 +- 8.295 uVs I2Y = -27.285 +- 0.763 uTm^2 16:04:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:04:53 Integrated Voltage Measurement... 16:05:02 Voltage Offset Correction: v_off_ini = 662.342 uV, v_off_fin = 666.680 uV 16:05:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.525 uVs 16:05:02 Integrated Voltage Measurement... 16:05:11 Voltage Offset Correction: v_off_ini = 672.910 uV, v_off_fin = 673.739 uV 16:05:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.794 uVs 16:05:11 Integrated Voltage Measurement... 16:05:20 Voltage Offset Correction: v_off_ini = 662.961 uV, v_off_fin = 654.441 uV 16:05:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.250 uVs 16:05:20 Integrated Voltage Measurement... 16:05:29 Voltage Offset Correction: v_off_ini = 662.240 uV, v_off_fin = 657.772 uV 16:05:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.606 uVs 16:05:29 Integrated Voltage Measurement... 16:05:38 Voltage Offset Correction: v_off_ini = 661.128 uV, v_off_fin = 664.002 uV 16:05:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.754 uVs 16:05:38 Integrated Voltage Measurement... 16:05:47 Voltage Offset Correction: v_off_ini = 660.069 uV, v_off_fin = 669.995 uV 16:05:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.338 uVs 16:05:51 I1X Average and RMS of Measurements VT = -80.211 +- 7.509 uVs I1X = 16.042 +- 1.501 uTm 16:05:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:05:58 Integrated Voltage Measurement... 16:06:07 Voltage Offset Correction: v_off_ini = 665.372 uV, v_off_fin = 658.180 uV 16:06:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -219.922 uVs 16:06:07 Integrated Voltage Measurement... 16:06:16 Voltage Offset Correction: v_off_ini = 675.132 uV, v_off_fin = 679.412 uV 16:06:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.469 uVs 16:06:16 Integrated Voltage Measurement... 16:06:25 Voltage Offset Correction: v_off_ini = 667.334 uV, v_off_fin = 648.358 uV 16:06:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.133 uVs 16:06:25 Integrated Voltage Measurement... 16:06:34 Voltage Offset Correction: v_off_ini = 678.819 uV, v_off_fin = 679.488 uV 16:06:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.315 uVs 16:06:34 Integrated Voltage Measurement... 16:06:43 Voltage Offset Correction: v_off_ini = 681.704 uV, v_off_fin = 667.790 uV 16:06:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.764 uVs 16:06:43 Integrated Voltage Measurement... 16:06:52 Voltage Offset Correction: v_off_ini = 672.368 uV, v_off_fin = 695.317 uV 16:06:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 242.139 uVs 16:06:56 I1Y Average and RMS of Measurements VT = -223.457 +- 5.618 uVs I1Y = -44.691 +- 1.121 uTm 16:06:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:07:01 Integrated Voltage Measurement... 16:07:10 Voltage Offset Correction: v_off_ini = 687.485 uV, v_off_fin = 685.049 uV 16:07:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.387 uVs 16:07:10 Integrated Voltage Measurement... 16:07:19 Voltage Offset Correction: v_off_ini = 702.074 uV, v_off_fin = 707.325 uV 16:07:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.807 uVs 16:07:19 Integrated Voltage Measurement... 16:07:28 Voltage Offset Correction: v_off_ini = 688.510 uV, v_off_fin = 685.262 uV 16:07:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.944 uVs 16:07:28 Integrated Voltage Measurement... 16:07:37 Voltage Offset Correction: v_off_ini = 695.317 uV, v_off_fin = 707.572 uV 16:07:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.415 uVs 16:07:37 Integrated Voltage Measurement... 16:07:46 Voltage Offset Correction: v_off_ini = 696.137 uV, v_off_fin = 701.265 uV 16:07:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.394 uVs 16:07:46 Integrated Voltage Measurement... 16:07:55 Voltage Offset Correction: v_off_ini = 687.204 uV, v_off_fin = 713.071 uV 16:07:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.711 uVs 16:07:57 I2X Average and RMS of Measurements VT = -54.443 +- 6.164 uVs I2X = 5.009 +- 0.567 uTm^2 16:08:00 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:08:03 Integrated Voltage Measurement... 16:08:12 Voltage Offset Correction: v_off_ini = 711.737 uV, v_off_fin = 717.591 uV 16:08:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.271 uVs 16:08:12 Integrated Voltage Measurement... 16:08:21 Voltage Offset Correction: v_off_ini = 704.978 uV, v_off_fin = 699.708 uV 16:08:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.502 uVs 16:08:21 Integrated Voltage Measurement... 16:08:30 Voltage Offset Correction: v_off_ini = 708.077 uV, v_off_fin = 703.355 uV 16:08:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.748 uVs 16:08:30 Integrated Voltage Measurement... 16:08:39 Voltage Offset Correction: v_off_ini = 697.599 uV, v_off_fin = 709.930 uV 16:08:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.877 uVs 16:08:39 Integrated Voltage Measurement... 16:08:48 Voltage Offset Correction: v_off_ini = 699.090 uV, v_off_fin = 698.584 uV 16:08:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.910 uVs 16:08:48 Integrated Voltage Measurement... 16:08:57 Voltage Offset Correction: v_off_ini = 701.634 uV, v_off_fin = 692.949 uV 16:08:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.661 uVs 16:08:59 I2Y Average and RMS of Measurements VT = -277.495 +- 8.565 uVs I2Y = -25.530 +- 0.788 uTm^2 16:09:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:09:20 Integrated Voltage Measurement... 16:09:29 Voltage Offset Correction: v_off_ini = 695.631 uV, v_off_fin = 691.625 uV 16:09:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.718 uVs 16:09:29 Integrated Voltage Measurement... 16:09:38 Voltage Offset Correction: v_off_ini = 702.441 uV, v_off_fin = 713.858 uV 16:09:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 125.637 uVs 16:09:38 Integrated Voltage Measurement... 16:09:47 Voltage Offset Correction: v_off_ini = 698.211 uV, v_off_fin = 706.390 uV 16:09:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.173 uVs 16:09:47 Integrated Voltage Measurement... 16:09:56 Voltage Offset Correction: v_off_ini = 697.630 uV, v_off_fin = 707.972 uV 16:09:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.461 uVs 16:09:56 Integrated Voltage Measurement... 16:10:05 Voltage Offset Correction: v_off_ini = 698.947 uV, v_off_fin = 702.452 uV 16:10:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.592 uVs 16:10:05 Integrated Voltage Measurement... 16:10:14 Voltage Offset Correction: v_off_ini = 711.440 uV, v_off_fin = 713.173 uV 16:10:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.856 uVs 16:10:19 I1X Average and RMS of Measurements VT = -115.406 +- 4.457 uVs I1X = 23.082 +- 0.893 uTm 16:10:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:10:25 Integrated Voltage Measurement... 16:10:34 Voltage Offset Correction: v_off_ini = 725.082 uV, v_off_fin = 700.388 uV 16:10:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.012 uVs 16:10:34 Integrated Voltage Measurement... 16:10:43 Voltage Offset Correction: v_off_ini = 711.502 uV, v_off_fin = 706.215 uV 16:10:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.949 uVs 16:10:43 Integrated Voltage Measurement... 16:10:52 Voltage Offset Correction: v_off_ini = 700.975 uV, v_off_fin = 702.313 uV 16:10:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.123 uVs 16:10:52 Integrated Voltage Measurement... 16:11:01 Voltage Offset Correction: v_off_ini = 725.764 uV, v_off_fin = 715.060 uV 16:11:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.698 uVs 16:11:01 Integrated Voltage Measurement... 16:11:10 Voltage Offset Correction: v_off_ini = 693.435 uV, v_off_fin = 685.755 uV 16:11:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.820 uVs 16:11:10 Integrated Voltage Measurement... 16:11:19 Voltage Offset Correction: v_off_ini = 704.309 uV, v_off_fin = 717.250 uV 16:11:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.650 uVs 16:11:23 I1Y Average and RMS of Measurements VT = -177.375 +- 1.699 uVs I1Y = -35.475 +- 0.340 uTm 16:11:29 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:11:31 Integrated Voltage Measurement... 16:11:40 Voltage Offset Correction: v_off_ini = 713.327 uV, v_off_fin = 701.931 uV 16:11:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.068 uVs 16:11:40 Integrated Voltage Measurement... 16:11:49 Voltage Offset Correction: v_off_ini = 714.827 uV, v_off_fin = 721.018 uV 16:11:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 114.368 uVs 16:11:49 Integrated Voltage Measurement... 16:11:58 Voltage Offset Correction: v_off_ini = 717.322 uV, v_off_fin = 719.464 uV 16:11:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.476 uVs 16:11:58 Integrated Voltage Measurement... 16:12:07 Voltage Offset Correction: v_off_ini = 727.197 uV, v_off_fin = 746.847 uV 16:12:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.820 uVs 16:12:07 Integrated Voltage Measurement... 16:12:16 Voltage Offset Correction: v_off_ini = 733.332 uV, v_off_fin = 740.248 uV 16:12:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.876 uVs 16:12:16 Integrated Voltage Measurement... 16:12:25 Voltage Offset Correction: v_off_ini = 740.293 uV, v_off_fin = 743.127 uV 16:12:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.433 uVs 16:12:28 I2X Average and RMS of Measurements VT = -100.174 +- 4.575 uVs I2X = 9.216 +- 0.421 uTm^2 16:12:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:12:35 Integrated Voltage Measurement... 16:12:44 Voltage Offset Correction: v_off_ini = 724.116 uV, v_off_fin = 729.324 uV 16:12:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.892 uVs 16:12:44 Integrated Voltage Measurement... 16:12:53 Voltage Offset Correction: v_off_ini = 726.889 uV, v_off_fin = 731.654 uV 16:12:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.321 uVs 16:12:53 Integrated Voltage Measurement... 16:13:02 Voltage Offset Correction: v_off_ini = 723.975 uV, v_off_fin = 728.583 uV 16:13:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.132 uVs 16:13:03 Integrated Voltage Measurement... 16:13:11 Voltage Offset Correction: v_off_ini = 740.494 uV, v_off_fin = 745.732 uV 16:13:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.842 uVs 16:13:12 Integrated Voltage Measurement... 16:13:21 Voltage Offset Correction: v_off_ini = 742.677 uV, v_off_fin = 726.195 uV 16:13:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.298 uVs 16:13:21 Integrated Voltage Measurement... 16:13:30 Voltage Offset Correction: v_off_ini = 726.229 uV, v_off_fin = 740.713 uV 16:13:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.771 uVs 16:13:32 I2Y Average and RMS of Measurements VT = -220.876 +- 9.507 uVs I2Y = -20.321 +- 0.875 uTm^2 16:13:37 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:13:41 Integrated Voltage Measurement... 16:13:50 Voltage Offset Correction: v_off_ini = 735.737 uV, v_off_fin = 743.015 uV 16:13:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -164.646 uVs 16:13:50 Integrated Voltage Measurement... 16:13:59 Voltage Offset Correction: v_off_ini = 738.645 uV, v_off_fin = 745.164 uV 16:13:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.127 uVs 16:13:59 Integrated Voltage Measurement... 16:14:08 Voltage Offset Correction: v_off_ini = 740.432 uV, v_off_fin = 742.615 uV 16:14:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.896 uVs 16:14:08 Integrated Voltage Measurement... 16:14:17 Voltage Offset Correction: v_off_ini = 741.025 uV, v_off_fin = 742.626 uV 16:14:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.252 uVs 16:14:17 Integrated Voltage Measurement... 16:14:26 Voltage Offset Correction: v_off_ini = 738.186 uV, v_off_fin = 730.435 uV 16:14:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.787 uVs 16:14:26 Integrated Voltage Measurement... 16:14:35 Voltage Offset Correction: v_off_ini = 737.185 uV, v_off_fin = 726.598 uV 16:14:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.686 uVs 16:14:39 I1X Average and RMS of Measurements VT = -123.399 +- 10.459 uVs I1X = 24.681 +- 2.094 uTm 16:14:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:14:46 Integrated Voltage Measurement... 16:14:55 Voltage Offset Correction: v_off_ini = 734.706 uV, v_off_fin = 730.729 uV 16:14:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.764 uVs 16:14:55 Integrated Voltage Measurement... 16:15:04 Voltage Offset Correction: v_off_ini = 742.515 uV, v_off_fin = 751.820 uV 16:15:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.631 uVs 16:15:04 Integrated Voltage Measurement... 16:15:13 Voltage Offset Correction: v_off_ini = 745.193 uV, v_off_fin = 726.826 uV 16:15:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.490 uVs 16:15:13 Integrated Voltage Measurement... 16:15:22 Voltage Offset Correction: v_off_ini = 737.073 uV, v_off_fin = 743.468 uV 16:15:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 206.135 uVs 16:15:22 Integrated Voltage Measurement... 16:15:31 Voltage Offset Correction: v_off_ini = 736.401 uV, v_off_fin = 733.635 uV 16:15:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.935 uVs 16:15:31 Integrated Voltage Measurement... 16:15:40 Voltage Offset Correction: v_off_ini = 748.040 uV, v_off_fin = 748.875 uV 16:15:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.608 uVs 16:15:44 I1Y Average and RMS of Measurements VT = -198.094 +- 7.308 uVs I1Y = -39.620 +- 1.462 uTm 16:15:49 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:15:52 Integrated Voltage Measurement... 16:16:01 Voltage Offset Correction: v_off_ini = 739.862 uV, v_off_fin = 756.335 uV 16:16:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.820 uVs 16:16:01 Integrated Voltage Measurement... 16:16:10 Voltage Offset Correction: v_off_ini = 761.435 uV, v_off_fin = 777.256 uV 16:16:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.582 uVs 16:16:10 Integrated Voltage Measurement... 16:16:19 Voltage Offset Correction: v_off_ini = 763.019 uV, v_off_fin = 754.561 uV 16:16:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.424 uVs 16:16:19 Integrated Voltage Measurement... 16:16:28 Voltage Offset Correction: v_off_ini = 748.194 uV, v_off_fin = 751.054 uV 16:16:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 99.635 uVs 16:16:28 Integrated Voltage Measurement... 16:16:37 Voltage Offset Correction: v_off_ini = 743.777 uV, v_off_fin = 739.985 uV 16:16:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.478 uVs 16:16:37 Integrated Voltage Measurement... 16:16:46 Voltage Offset Correction: v_off_ini = 759.065 uV, v_off_fin = 767.650 uV 16:16:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 113.967 uVs 16:16:48 I2X Average and RMS of Measurements VT = -97.651 +- 2.868 uVs I2X = 8.984 +- 0.264 uTm^2 16:16:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:16:56 Integrated Voltage Measurement... 16:17:05 Voltage Offset Correction: v_off_ini = 760.563 uV, v_off_fin = 759.291 uV 16:17:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.338 uVs 16:17:05 Integrated Voltage Measurement... 16:17:14 Voltage Offset Correction: v_off_ini = 761.184 uV, v_off_fin = 751.926 uV 16:17:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.122 uVs 16:17:14 Integrated Voltage Measurement... 16:17:23 Voltage Offset Correction: v_off_ini = 736.475 uV, v_off_fin = 747.052 uV 16:17:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.794 uVs 16:17:23 Integrated Voltage Measurement... 16:17:32 Voltage Offset Correction: v_off_ini = 751.293 uV, v_off_fin = 744.553 uV 16:17:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.948 uVs 16:17:32 Integrated Voltage Measurement... 16:17:41 Voltage Offset Correction: v_off_ini = 734.849 uV, v_off_fin = 736.874 uV 16:17:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.665 uVs 16:17:41 Integrated Voltage Measurement... 16:17:50 Voltage Offset Correction: v_off_ini = 764.429 uV, v_off_fin = 757.161 uV 16:17:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.329 uVs 16:17:53 I2Y Average and RMS of Measurements VT = -257.533 +- 2.422 uVs I2Y = -23.693 +- 0.223 uTm^2 16:17:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:18:02 Integrated Voltage Measurement... 16:18:10 Voltage Offset Correction: v_off_ini = 751.369 uV, v_off_fin = 759.204 uV 16:18:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.931 uVs 16:18:11 Integrated Voltage Measurement... 16:18:20 Voltage Offset Correction: v_off_ini = 755.359 uV, v_off_fin = 760.894 uV 16:18:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.061 uVs 16:18:20 Integrated Voltage Measurement... 16:18:29 Voltage Offset Correction: v_off_ini = 759.306 uV, v_off_fin = 749.262 uV 16:18:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.438 uVs 16:18:29 Integrated Voltage Measurement... 16:18:38 Voltage Offset Correction: v_off_ini = 767.927 uV, v_off_fin = 769.929 uV 16:18:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.453 uVs 16:18:38 Integrated Voltage Measurement... 16:18:47 Voltage Offset Correction: v_off_ini = 766.964 uV, v_off_fin = 768.719 uV 16:18:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.760 uVs 16:18:47 Integrated Voltage Measurement... 16:18:56 Voltage Offset Correction: v_off_ini = 766.885 uV, v_off_fin = 762.484 uV 16:18:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.554 uVs 16:19:00 I1X Average and RMS of Measurements VT = -110.866 +- 5.665 uVs I1X = 22.174 +- 1.132 uTm 16:19:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:07 Integrated Voltage Measurement... 16:19:16 Voltage Offset Correction: v_off_ini = 760.687 uV, v_off_fin = 754.704 uV 16:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.300 uVs 16:19:16 Integrated Voltage Measurement... 16:19:25 Voltage Offset Correction: v_off_ini = 770.361 uV, v_off_fin = 769.872 uV 16:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.209 uVs 16:19:25 Integrated Voltage Measurement... 16:19:34 Voltage Offset Correction: v_off_ini = 765.445 uV, v_off_fin = 757.740 uV 16:19:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.469 uVs 16:19:34 Integrated Voltage Measurement... 16:19:43 Voltage Offset Correction: v_off_ini = 786.401 uV, v_off_fin = 790.804 uV 16:19:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.603 uVs 16:19:43 Integrated Voltage Measurement... 16:19:52 Voltage Offset Correction: v_off_ini = 786.276 uV, v_off_fin = 765.508 uV 16:19:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.320 uVs 16:19:52 Integrated Voltage Measurement... 16:20:01 Voltage Offset Correction: v_off_ini = 801.350 uV, v_off_fin = 791.015 uV 16:20:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.941 uVs 16:20:05 I1Y Average and RMS of Measurements VT = -208.640 +- 4.952 uVs I1Y = -41.728 +- 0.990 uTm 16:20:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:13 Integrated Voltage Measurement... 16:20:22 Voltage Offset Correction: v_off_ini = 781.593 uV, v_off_fin = 773.307 uV 16:20:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -84.986 uVs 16:20:22 Integrated Voltage Measurement... 16:20:31 Voltage Offset Correction: v_off_ini = 787.806 uV, v_off_fin = 783.631 uV 16:20:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.383 uVs 16:20:31 Integrated Voltage Measurement... 16:20:40 Voltage Offset Correction: v_off_ini = 776.378 uV, v_off_fin = 765.511 uV 16:20:40 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.942 uVs 16:20:40 Integrated Voltage Measurement... 16:20:49 Voltage Offset Correction: v_off_ini = 791.715 uV, v_off_fin = 796.967 uV 16:20:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.053 uVs 16:20:49 Integrated Voltage Measurement... 16:20:58 Voltage Offset Correction: v_off_ini = 785.173 uV, v_off_fin = 782.331 uV 16:20:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -95.634 uVs 16:20:58 Integrated Voltage Measurement... 16:21:07 Voltage Offset Correction: v_off_ini = 791.861 uV, v_off_fin = 793.476 uV 16:21:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.300 uVs 16:21:09 I2X Average and RMS of Measurements VT = -84.216 +- 1.245 uVs I2X = 7.749 +- 0.114 uTm^2 16:21:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:17 Integrated Voltage Measurement... 16:21:26 Voltage Offset Correction: v_off_ini = 792.242 uV, v_off_fin = 791.101 uV 16:21:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.685 uVs 16:21:26 Integrated Voltage Measurement... 16:21:35 Voltage Offset Correction: v_off_ini = 807.598 uV, v_off_fin = 797.142 uV 16:21:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.345 uVs 16:21:35 Integrated Voltage Measurement... 16:21:44 Voltage Offset Correction: v_off_ini = 783.288 uV, v_off_fin = 783.163 uV 16:21:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.816 uVs 16:21:44 Integrated Voltage Measurement... 16:21:53 Voltage Offset Correction: v_off_ini = 794.614 uV, v_off_fin = 789.164 uV 16:21:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.965 uVs 16:21:53 Integrated Voltage Measurement... 16:22:02 Voltage Offset Correction: v_off_ini = 787.415 uV, v_off_fin = 777.852 uV 16:22:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.682 uVs 16:22:02 Integrated Voltage Measurement... 16:22:11 Voltage Offset Correction: v_off_ini = 798.248 uV, v_off_fin = 800.755 uV 16:22:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.185 uVs 16:22:14 I2Y Average and RMS of Measurements VT = -266.946 +- 3.195 uVs I2Y = -24.559 +- 0.294 uTm^2 16:22:18 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:22:23 Integrated Voltage Measurement... 16:22:32 Voltage Offset Correction: v_off_ini = 783.556 uV, v_off_fin = 790.788 uV 16:22:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -123.466 uVs 16:22:32 Integrated Voltage Measurement... 16:22:41 Voltage Offset Correction: v_off_ini = 786.663 uV, v_off_fin = 795.209 uV 16:22:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.998 uVs 16:22:41 Integrated Voltage Measurement... 16:22:50 Voltage Offset Correction: v_off_ini = 783.265 uV, v_off_fin = 786.014 uV 16:22:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.382 uVs 16:22:50 Integrated Voltage Measurement... 16:22:59 Voltage Offset Correction: v_off_ini = 795.334 uV, v_off_fin = 785.792 uV 16:22:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.082 uVs 16:22:59 Integrated Voltage Measurement... 16:23:08 Voltage Offset Correction: v_off_ini = 787.918 uV, v_off_fin = 779.978 uV 16:23:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.699 uVs 16:23:08 Integrated Voltage Measurement... 16:23:17 Voltage Offset Correction: v_off_ini = 773.192 uV, v_off_fin = 777.011 uV 16:23:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.292 uVs 16:23:21 I1X Average and RMS of Measurements VT = -119.986 +- 4.948 uVs I1X = 23.999 +- 0.990 uTm 16:23:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:23:28 Integrated Voltage Measurement... 16:23:37 Voltage Offset Correction: v_off_ini = 791.606 uV, v_off_fin = 768.871 uV 16:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -218.988 uVs 16:23:37 Integrated Voltage Measurement... 16:23:46 Voltage Offset Correction: v_off_ini = 779.472 uV, v_off_fin = 794.269 uV 16:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.778 uVs 16:23:46 Integrated Voltage Measurement... 16:23:55 Voltage Offset Correction: v_off_ini = 776.219 uV, v_off_fin = 743.251 uV 16:23:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.946 uVs 16:23:55 Integrated Voltage Measurement... 16:24:04 Voltage Offset Correction: v_off_ini = 771.520 uV, v_off_fin = 776.438 uV 16:24:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.095 uVs 16:24:04 Integrated Voltage Measurement... 16:24:13 Voltage Offset Correction: v_off_ini = 778.582 uV, v_off_fin = 770.500 uV 16:24:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.549 uVs 16:24:13 Integrated Voltage Measurement... 16:24:22 Voltage Offset Correction: v_off_ini = 767.891 uV, v_off_fin = 777.354 uV 16:24:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.491 uVs 16:24:26 I1Y Average and RMS of Measurements VT = -227.974 +- 3.947 uVs I1Y = -45.596 +- 0.789 uTm 16:24:31 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:24:34 Integrated Voltage Measurement... 16:24:43 Voltage Offset Correction: v_off_ini = 766.762 uV, v_off_fin = 750.841 uV 16:24:43 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -74.570 uVs 16:24:43 Integrated Voltage Measurement... 16:24:52 Voltage Offset Correction: v_off_ini = 763.705 uV, v_off_fin = 774.473 uV 16:24:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.687 uVs 16:24:52 Integrated Voltage Measurement... 16:25:01 Voltage Offset Correction: v_off_ini = 753.153 uV, v_off_fin = 750.993 uV 16:25:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.420 uVs 16:25:01 Integrated Voltage Measurement... 16:25:10 Voltage Offset Correction: v_off_ini = 768.095 uV, v_off_fin = 778.592 uV 16:25:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.586 uVs 16:25:10 Integrated Voltage Measurement... 16:25:19 Voltage Offset Correction: v_off_ini = 782.929 uV, v_off_fin = 771.137 uV 16:25:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.542 uVs 16:25:19 Integrated Voltage Measurement... 16:25:28 Voltage Offset Correction: v_off_ini = 783.564 uV, v_off_fin = 788.003 uV 16:25:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.322 uVs 16:25:30 I2X Average and RMS of Measurements VT = -74.021 +- 5.687 uVs I2X = 6.810 +- 0.523 uTm^2 16:25:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:25:38 Integrated Voltage Measurement... 16:25:47 Voltage Offset Correction: v_off_ini = 782.341 uV, v_off_fin = 774.112 uV 16:25:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.838 uVs 16:25:47 Integrated Voltage Measurement... 16:25:56 Voltage Offset Correction: v_off_ini = 768.366 uV, v_off_fin = 759.467 uV 16:25:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.136 uVs 16:25:56 Integrated Voltage Measurement... 16:26:05 Voltage Offset Correction: v_off_ini = 762.448 uV, v_off_fin = 765.410 uV 16:26:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.639 uVs 16:26:05 Integrated Voltage Measurement... 16:26:14 Voltage Offset Correction: v_off_ini = 756.287 uV, v_off_fin = 762.339 uV 16:26:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.826 uVs 16:26:14 Integrated Voltage Measurement... 16:26:23 Voltage Offset Correction: v_off_ini = 760.326 uV, v_off_fin = 753.591 uV 16:26:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.046 uVs 16:26:23 Integrated Voltage Measurement... 16:26:32 Voltage Offset Correction: v_off_ini = 781.903 uV, v_off_fin = 770.641 uV 16:26:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.626 uVs 16:26:35 I2Y Average and RMS of Measurements VT = -292.185 +- 5.529 uVs I2Y = -26.881 +- 0.509 uTm^2 16:26:39 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:26:44 Integrated Voltage Measurement... 16:26:53 Voltage Offset Correction: v_off_ini = 771.907 uV, v_off_fin = 759.950 uV 16:26:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.847 uVs 16:26:53 Integrated Voltage Measurement... 16:27:02 Voltage Offset Correction: v_off_ini = 774.390 uV, v_off_fin = 771.348 uV 16:27:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.505 uVs 16:27:02 Integrated Voltage Measurement... 16:27:11 Voltage Offset Correction: v_off_ini = 758.231 uV, v_off_fin = 764.324 uV 16:27:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.862 uVs 16:27:11 Integrated Voltage Measurement... 16:27:20 Voltage Offset Correction: v_off_ini = 773.373 uV, v_off_fin = 766.298 uV 16:27:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.533 uVs 16:27:20 Integrated Voltage Measurement... 16:27:29 Voltage Offset Correction: v_off_ini = 773.224 uV, v_off_fin = 746.078 uV 16:27:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.552 uVs 16:27:29 Integrated Voltage Measurement... 16:27:38 Voltage Offset Correction: v_off_ini = 765.065 uV, v_off_fin = 768.060 uV 16:27:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.151 uVs 16:27:42 I1X Average and RMS of Measurements VT = -117.575 +- 8.252 uVs I1X = 23.515 +- 1.650 uTm 16:27:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:27:49 Integrated Voltage Measurement... 16:27:58 Voltage Offset Correction: v_off_ini = 767.987 uV, v_off_fin = 747.518 uV 16:27:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.666 uVs 16:27:58 Integrated Voltage Measurement... 16:28:07 Voltage Offset Correction: v_off_ini = 762.523 uV, v_off_fin = 769.095 uV 16:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.790 uVs 16:28:07 Integrated Voltage Measurement... 16:28:16 Voltage Offset Correction: v_off_ini = 761.969 uV, v_off_fin = 757.349 uV 16:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.300 uVs 16:28:16 Integrated Voltage Measurement... 16:28:25 Voltage Offset Correction: v_off_ini = 779.737 uV, v_off_fin = 794.415 uV 16:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.015 uVs 16:28:25 Integrated Voltage Measurement... 16:28:34 Voltage Offset Correction: v_off_ini = 772.579 uV, v_off_fin = 756.333 uV 16:28:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.189 uVs 16:28:34 Integrated Voltage Measurement... 16:28:43 Voltage Offset Correction: v_off_ini = 770.463 uV, v_off_fin = 777.852 uV 16:28:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.680 uVs 16:28:47 I1Y Average and RMS of Measurements VT = -235.273 +- 6.048 uVs I1Y = -47.055 +- 1.210 uTm 16:28:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:28:55 Integrated Voltage Measurement... 16:29:04 Voltage Offset Correction: v_off_ini = 762.630 uV, v_off_fin = 757.211 uV 16:29:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.860 uVs 16:29:04 Integrated Voltage Measurement... 16:29:13 Voltage Offset Correction: v_off_ini = 754.903 uV, v_off_fin = 764.584 uV 16:29:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.658 uVs 16:29:13 Integrated Voltage Measurement... 16:29:22 Voltage Offset Correction: v_off_ini = 769.600 uV, v_off_fin = 758.239 uV 16:29:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.590 uVs 16:29:22 Integrated Voltage Measurement... 16:29:31 Voltage Offset Correction: v_off_ini = 778.975 uV, v_off_fin = 783.667 uV 16:29:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.142 uVs 16:29:31 Integrated Voltage Measurement... 16:29:40 Voltage Offset Correction: v_off_ini = 776.258 uV, v_off_fin = 761.479 uV 16:29:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.903 uVs 16:29:40 Integrated Voltage Measurement... 16:29:49 Voltage Offset Correction: v_off_ini = 773.688 uV, v_off_fin = 775.890 uV 16:29:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.259 uVs 16:29:51 I2X Average and RMS of Measurements VT = -68.235 +- 4.299 uVs I2X = 6.278 +- 0.395 uTm^2 16:29:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:29:59 Integrated Voltage Measurement... 16:30:08 Voltage Offset Correction: v_off_ini = 766.986 uV, v_off_fin = 763.714 uV 16:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.809 uVs 16:30:08 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = 774.728 uV, v_off_fin = 783.026 uV 16:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.797 uVs 16:30:17 Integrated Voltage Measurement... 16:30:26 Voltage Offset Correction: v_off_ini = 776.093 uV, v_off_fin = 783.152 uV 16:30:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.545 uVs 16:30:26 Integrated Voltage Measurement... 16:30:35 Voltage Offset Correction: v_off_ini = 784.801 uV, v_off_fin = 791.108 uV 16:30:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.474 uVs 16:30:35 Integrated Voltage Measurement... 16:30:44 Voltage Offset Correction: v_off_ini = 779.838 uV, v_off_fin = 761.853 uV 16:30:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.777 uVs 16:30:44 Integrated Voltage Measurement... 16:30:53 Voltage Offset Correction: v_off_ini = 752.407 uV, v_off_fin = 762.256 uV 16:30:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.550 uVs 16:30:56 I2Y Average and RMS of Measurements VT = -295.492 +- 4.995 uVs I2Y = -27.185 +- 0.460 uTm^2 16:31:03 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:31:08 Integrated Voltage Measurement... 16:31:17 Voltage Offset Correction: v_off_ini = 770.428 uV, v_off_fin = 775.551 uV 16:31:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -125.933 uVs 16:31:17 Integrated Voltage Measurement... 16:31:26 Voltage Offset Correction: v_off_ini = 763.319 uV, v_off_fin = 755.745 uV 16:31:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.643 uVs 16:31:26 Integrated Voltage Measurement... 16:31:35 Voltage Offset Correction: v_off_ini = 762.173 uV, v_off_fin = 764.733 uV 16:31:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.003 uVs 16:31:35 Integrated Voltage Measurement... 16:31:44 Voltage Offset Correction: v_off_ini = 759.001 uV, v_off_fin = 763.759 uV 16:31:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.252 uVs 16:31:44 Integrated Voltage Measurement... 16:31:53 Voltage Offset Correction: v_off_ini = 766.540 uV, v_off_fin = 789.020 uV 16:31:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.464 uVs 16:31:53 Integrated Voltage Measurement... 16:32:02 Voltage Offset Correction: v_off_ini = 795.648 uV, v_off_fin = 776.992 uV 16:32:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.140 uVs 16:32:06 I1X Average and RMS of Measurements VT = -122.739 +- 8.821 uVs I1X = 24.549 +- 1.765 uTm 16:32:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:32:13 Integrated Voltage Measurement... 16:32:22 Voltage Offset Correction: v_off_ini = 776.807 uV, v_off_fin = 772.529 uV 16:32:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.894 uVs 16:32:22 Integrated Voltage Measurement... 16:32:31 Voltage Offset Correction: v_off_ini = 785.843 uV, v_off_fin = 795.101 uV 16:32:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.080 uVs 16:32:31 Integrated Voltage Measurement... 16:32:40 Voltage Offset Correction: v_off_ini = 771.014 uV, v_off_fin = 771.548 uV 16:32:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.817 uVs 16:32:40 Integrated Voltage Measurement... 16:32:49 Voltage Offset Correction: v_off_ini = 787.407 uV, v_off_fin = 790.109 uV 16:32:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.397 uVs 16:32:49 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = 785.074 uV, v_off_fin = 770.117 uV 16:32:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.378 uVs 16:32:58 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = 784.218 uV, v_off_fin = 804.899 uV 16:33:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.788 uVs 16:33:11 I1Y Average and RMS of Measurements VT = -210.226 +- 10.934 uVs I1Y = -42.045 +- 2.187 uTm 16:33:14 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:33:16 Integrated Voltage Measurement... 16:33:25 Voltage Offset Correction: v_off_ini = 779.646 uV, v_off_fin = 773.802 uV 16:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.733 uVs 16:33:25 Integrated Voltage Measurement... 16:33:34 Voltage Offset Correction: v_off_ini = 783.750 uV, v_off_fin = 784.726 uV 16:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.499 uVs 16:33:34 Integrated Voltage Measurement... 16:33:43 Voltage Offset Correction: v_off_ini = 785.968 uV, v_off_fin = 777.956 uV 16:33:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.528 uVs 16:33:43 Integrated Voltage Measurement... 16:33:52 Voltage Offset Correction: v_off_ini = 799.249 uV, v_off_fin = 808.173 uV 16:33:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.572 uVs 16:33:52 Integrated Voltage Measurement... 16:34:01 Voltage Offset Correction: v_off_ini = 788.379 uV, v_off_fin = 785.182 uV 16:34:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.485 uVs 16:34:01 Integrated Voltage Measurement... 16:34:10 Voltage Offset Correction: v_off_ini = 798.039 uV, v_off_fin = 786.399 uV 16:34:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.613 uVs 16:34:13 I2X Average and RMS of Measurements VT = -100.072 +- 3.261 uVs I2X = 9.207 +- 0.300 uTm^2 16:34:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:34:18 Integrated Voltage Measurement... 16:34:27 Voltage Offset Correction: v_off_ini = 790.187 uV, v_off_fin = 779.493 uV 16:34:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.563 uVs 16:34:27 Integrated Voltage Measurement... 16:34:36 Voltage Offset Correction: v_off_ini = 782.567 uV, v_off_fin = 787.620 uV 16:34:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.938 uVs 16:34:36 Integrated Voltage Measurement... 16:34:45 Voltage Offset Correction: v_off_ini = 797.184 uV, v_off_fin = 783.140 uV 16:34:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.352 uVs 16:34:45 Integrated Voltage Measurement... 16:34:54 Voltage Offset Correction: v_off_ini = 777.284 uV, v_off_fin = 783.539 uV 16:34:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.447 uVs 16:34:54 Integrated Voltage Measurement... 16:35:03 Voltage Offset Correction: v_off_ini = 775.960 uV, v_off_fin = 778.178 uV 16:35:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.436 uVs 16:35:03 Integrated Voltage Measurement... 16:35:12 Voltage Offset Correction: v_off_ini = 798.478 uV, v_off_fin = 781.341 uV 16:35:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.251 uVs 16:35:15 I2Y Average and RMS of Measurements VT = -270.665 +- 0.936 uVs I2Y = -24.901 +- 0.086 uTm^2 16:35:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:35:23 Integrated Voltage Measurement... 16:35:32 Voltage Offset Correction: v_off_ini = 789.619 uV, v_off_fin = 791.033 uV 16:35:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -129.734 uVs 16:35:32 Integrated Voltage Measurement... 16:35:41 Voltage Offset Correction: v_off_ini = 787.722 uV, v_off_fin = 796.287 uV 16:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.345 uVs 16:35:41 Integrated Voltage Measurement... 16:35:50 Voltage Offset Correction: v_off_ini = 798.938 uV, v_off_fin = 803.733 uV 16:35:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.411 uVs 16:35:50 Integrated Voltage Measurement... 16:35:59 Voltage Offset Correction: v_off_ini = 779.890 uV, v_off_fin = 797.311 uV 16:35:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 117.888 uVs 16:35:59 Integrated Voltage Measurement... 16:36:08 Voltage Offset Correction: v_off_ini = 788.810 uV, v_off_fin = 791.711 uV 16:36:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.654 uVs 16:36:08 Integrated Voltage Measurement... 16:36:17 Voltage Offset Correction: v_off_ini = 792.697 uV, v_off_fin = 802.372 uV 16:36:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.538 uVs 16:36:21 I1X Average and RMS of Measurements VT = -128.262 +- 0.241 uVs I1X = 25.654 +- 0.047 uTm 16:36:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:36:28 Integrated Voltage Measurement... 16:36:37 Voltage Offset Correction: v_off_ini = 791.403 uV, v_off_fin = 776.037 uV 16:36:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.895 uVs 16:36:37 Integrated Voltage Measurement... 16:36:46 Voltage Offset Correction: v_off_ini = 786.008 uV, v_off_fin = 787.949 uV 16:36:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.624 uVs 16:36:46 Integrated Voltage Measurement... 16:36:55 Voltage Offset Correction: v_off_ini = 785.838 uV, v_off_fin = 779.304 uV 16:36:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.677 uVs 16:36:55 Integrated Voltage Measurement... 16:37:04 Voltage Offset Correction: v_off_ini = 814.615 uV, v_off_fin = 805.142 uV 16:37:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.096 uVs 16:37:04 Integrated Voltage Measurement... 16:37:13 Voltage Offset Correction: v_off_ini = 801.169 uV, v_off_fin = 784.062 uV 16:37:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.775 uVs 16:37:13 Integrated Voltage Measurement... 16:37:22 Voltage Offset Correction: v_off_ini = 787.550 uV, v_off_fin = 798.610 uV 16:37:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.509 uVs 16:37:26 I1Y Average and RMS of Measurements VT = -215.763 +- 0.366 uVs I1Y = -43.153 +- 0.073 uTm 16:37:29 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:37:31 Integrated Voltage Measurement... 16:37:40 Voltage Offset Correction: v_off_ini = 791.557 uV, v_off_fin = 792.860 uV 16:37:40 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -77.705 uVs 16:37:40 Integrated Voltage Measurement... 16:37:49 Voltage Offset Correction: v_off_ini = 797.216 uV, v_off_fin = 790.148 uV 16:37:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.320 uVs 16:37:49 Integrated Voltage Measurement... 16:37:58 Voltage Offset Correction: v_off_ini = 780.209 uV, v_off_fin = 779.526 uV 16:37:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.606 uVs 16:37:58 Integrated Voltage Measurement... 16:38:07 Voltage Offset Correction: v_off_ini = 790.954 uV, v_off_fin = 785.124 uV 16:38:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.135 uVs 16:38:07 Integrated Voltage Measurement... 16:38:16 Voltage Offset Correction: v_off_ini = 779.553 uV, v_off_fin = 775.895 uV 16:38:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.956 uVs 16:38:16 Integrated Voltage Measurement... 16:38:25 Voltage Offset Correction: v_off_ini = 783.149 uV, v_off_fin = 792.100 uV 16:38:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.218 uVs 16:38:28 I2X Average and RMS of Measurements VT = -90.990 +- 2.393 uVs I2X = 8.371 +- 0.220 uTm^2 16:38:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:38:33 Integrated Voltage Measurement... 16:38:42 Voltage Offset Correction: v_off_ini = 785.404 uV, v_off_fin = 779.108 uV 16:38:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.144 uVs 16:38:42 Integrated Voltage Measurement... 16:38:51 Voltage Offset Correction: v_off_ini = 786.694 uV, v_off_fin = 777.669 uV 16:38:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.630 uVs 16:38:51 Integrated Voltage Measurement... 16:39:00 Voltage Offset Correction: v_off_ini = 786.473 uV, v_off_fin = 788.367 uV 16:39:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.125 uVs 16:39:00 Integrated Voltage Measurement... 16:39:09 Voltage Offset Correction: v_off_ini = 798.069 uV, v_off_fin = 797.400 uV 16:39:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.540 uVs 16:39:09 Integrated Voltage Measurement... 16:39:18 Voltage Offset Correction: v_off_ini = 784.054 uV, v_off_fin = 796.777 uV 16:39:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.817 uVs 16:39:18 Integrated Voltage Measurement... 16:39:27 Voltage Offset Correction: v_off_ini = 795.750 uV, v_off_fin = 789.761 uV 16:39:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.720 uVs 16:39:29 I2Y Average and RMS of Measurements VT = -265.663 +- 1.589 uVs I2Y = -24.441 +- 0.146 uTm^2 16:39:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:38 Integrated Voltage Measurement... 16:39:47 Voltage Offset Correction: v_off_ini = 793.216 uV, v_off_fin = 798.875 uV 16:39:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -111.823 uVs 16:39:47 Integrated Voltage Measurement... 16:39:56 Voltage Offset Correction: v_off_ini = 796.324 uV, v_off_fin = 789.837 uV 16:39:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.426 uVs 16:39:56 Integrated Voltage Measurement... 16:40:05 Voltage Offset Correction: v_off_ini = 784.672 uV, v_off_fin = 794.850 uV 16:40:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.193 uVs 16:40:05 Integrated Voltage Measurement... 16:40:14 Voltage Offset Correction: v_off_ini = 808.869 uV, v_off_fin = 824.751 uV 16:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.210 uVs 16:40:14 Integrated Voltage Measurement... 16:40:23 Voltage Offset Correction: v_off_ini = 814.448 uV, v_off_fin = 808.980 uV 16:40:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.394 uVs 16:40:23 Integrated Voltage Measurement... 16:40:32 Voltage Offset Correction: v_off_ini = 796.457 uV, v_off_fin = 798.107 uV 16:40:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.947 uVs 16:40:36 I1X Average and RMS of Measurements VT = -110.999 +- 2.688 uVs I1X = 22.200 +- 0.537 uTm 16:40:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:43 Integrated Voltage Measurement... 16:40:52 Voltage Offset Correction: v_off_ini = 797.844 uV, v_off_fin = 784.017 uV 16:40:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.444 uVs 16:40:52 Integrated Voltage Measurement... 16:41:01 Voltage Offset Correction: v_off_ini = 796.173 uV, v_off_fin = 820.525 uV 16:41:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.119 uVs 16:41:01 Integrated Voltage Measurement... 16:41:10 Voltage Offset Correction: v_off_ini = 790.492 uV, v_off_fin = 788.666 uV 16:41:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.061 uVs 16:41:10 Integrated Voltage Measurement... 16:41:19 Voltage Offset Correction: v_off_ini = 787.451 uV, v_off_fin = 798.363 uV 16:41:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.985 uVs 16:41:19 Integrated Voltage Measurement... 16:41:28 Voltage Offset Correction: v_off_ini = 799.515 uV, v_off_fin = 778.417 uV 16:41:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.130 uVs 16:41:28 Integrated Voltage Measurement... 16:41:37 Voltage Offset Correction: v_off_ini = 799.267 uV, v_off_fin = 799.570 uV 16:41:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.682 uVs 16:41:41 I1Y Average and RMS of Measurements VT = -209.404 +- 2.849 uVs I1Y = -41.881 +- 0.569 uTm 16:41:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:46 Integrated Voltage Measurement... 16:41:55 Voltage Offset Correction: v_off_ini = 793.068 uV, v_off_fin = 783.241 uV 16:41:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -99.773 uVs 16:41:55 Integrated Voltage Measurement... 16:42:04 Voltage Offset Correction: v_off_ini = 793.279 uV, v_off_fin = 801.089 uV 16:42:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.850 uVs 16:42:04 Integrated Voltage Measurement... 16:42:13 Voltage Offset Correction: v_off_ini = 808.855 uV, v_off_fin = 786.133 uV 16:42:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.487 uVs 16:42:13 Integrated Voltage Measurement... 16:42:22 Voltage Offset Correction: v_off_ini = 785.117 uV, v_off_fin = 784.775 uV 16:42:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.369 uVs 16:42:22 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = 780.803 uV, v_off_fin = 777.840 uV 16:42:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.069 uVs 16:42:31 Integrated Voltage Measurement... 16:42:40 Voltage Offset Correction: v_off_ini = 793.844 uV, v_off_fin = 803.540 uV 16:42:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.186 uVs 16:42:43 I2X Average and RMS of Measurements VT = -96.289 +- 3.019 uVs I2X = 8.858 +- 0.278 uTm^2 16:42:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:48 Integrated Voltage Measurement... 16:42:57 Voltage Offset Correction: v_off_ini = 793.904 uV, v_off_fin = 790.948 uV 16:42:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.491 uVs 16:42:57 Integrated Voltage Measurement... 16:43:06 Voltage Offset Correction: v_off_ini = 789.847 uV, v_off_fin = 789.230 uV 16:43:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.869 uVs 16:43:06 Integrated Voltage Measurement... 16:43:15 Voltage Offset Correction: v_off_ini = 793.147 uV, v_off_fin = 787.900 uV 16:43:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.822 uVs 16:43:15 Integrated Voltage Measurement... 16:43:24 Voltage Offset Correction: v_off_ini = 792.112 uV, v_off_fin = 799.963 uV 16:43:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.928 uVs 16:43:24 Integrated Voltage Measurement... 16:43:33 Voltage Offset Correction: v_off_ini = 790.031 uV, v_off_fin = 792.512 uV 16:43:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.159 uVs 16:43:33 Integrated Voltage Measurement... 16:43:42 Voltage Offset Correction: v_off_ini = 800.412 uV, v_off_fin = 792.216 uV 16:43:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.718 uVs 16:43:44 I2Y Average and RMS of Measurements VT = -264.664 +- 5.584 uVs I2Y = -24.349 +- 0.514 uTm^2 16:43:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:43:53 Integrated Voltage Measurement... 16:44:02 Voltage Offset Correction: v_off_ini = 798.977 uV, v_off_fin = 795.421 uV 16:44:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -97.981 uVs 16:44:02 Integrated Voltage Measurement... 16:44:11 Voltage Offset Correction: v_off_ini = 804.916 uV, v_off_fin = 796.627 uV 16:44:11 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.362 uVs 16:44:11 Integrated Voltage Measurement... 16:44:20 Voltage Offset Correction: v_off_ini = 789.703 uV, v_off_fin = 789.793 uV 16:44:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.815 uVs 16:44:20 Integrated Voltage Measurement... 16:44:29 Voltage Offset Correction: v_off_ini = 793.127 uV, v_off_fin = 792.430 uV 16:44:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.939 uVs 16:44:29 Integrated Voltage Measurement... 16:44:38 Voltage Offset Correction: v_off_ini = 793.376 uV, v_off_fin = 791.028 uV 16:44:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.585 uVs 16:44:38 Integrated Voltage Measurement... 16:44:47 Voltage Offset Correction: v_off_ini = 798.385 uV, v_off_fin = 811.425 uV 16:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.493 uVs 16:44:51 I1X Average and RMS of Measurements VT = -100.863 +- 1.908 uVs I1X = 20.174 +- 0.380 uTm 16:44:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:44:58 Integrated Voltage Measurement... 16:45:07 Voltage Offset Correction: v_off_ini = 785.589 uV, v_off_fin = 777.225 uV 16:45:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -218.909 uVs 16:45:07 Integrated Voltage Measurement... 16:45:16 Voltage Offset Correction: v_off_ini = 789.963 uV, v_off_fin = 795.015 uV 16:45:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.654 uVs 16:45:16 Integrated Voltage Measurement... 16:45:25 Voltage Offset Correction: v_off_ini = 807.008 uV, v_off_fin = 800.805 uV 16:45:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -194.564 uVs 16:45:25 Integrated Voltage Measurement... 16:45:34 Voltage Offset Correction: v_off_ini = 812.259 uV, v_off_fin = 807.448 uV 16:45:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.589 uVs 16:45:34 Integrated Voltage Measurement... 16:45:43 Voltage Offset Correction: v_off_ini = 800.918 uV, v_off_fin = 798.209 uV 16:45:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.235 uVs 16:45:43 Integrated Voltage Measurement... 16:45:52 Voltage Offset Correction: v_off_ini = 792.484 uV, v_off_fin = 795.324 uV 16:45:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 212.107 uVs 16:45:56 I1Y Average and RMS of Measurements VT = -208.676 +- 6.174 uVs I1Y = -41.732 +- 1.235 uTm 16:45:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:46:01 Integrated Voltage Measurement... 16:46:10 Voltage Offset Correction: v_off_ini = 787.171 uV, v_off_fin = 782.080 uV 16:46:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.907 uVs 16:46:10 Integrated Voltage Measurement... 16:46:19 Voltage Offset Correction: v_off_ini = 775.317 uV, v_off_fin = 800.063 uV 16:46:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.218 uVs 16:46:19 Integrated Voltage Measurement... 16:46:28 Voltage Offset Correction: v_off_ini = 790.201 uV, v_off_fin = 778.019 uV 16:46:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.394 uVs 16:46:28 Integrated Voltage Measurement... 16:46:37 Voltage Offset Correction: v_off_ini = 787.857 uV, v_off_fin = 791.988 uV 16:46:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.083 uVs 16:46:37 Integrated Voltage Measurement... 16:46:46 Voltage Offset Correction: v_off_ini = 779.155 uV, v_off_fin = 772.949 uV 16:46:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.090 uVs 16:46:46 Integrated Voltage Measurement... 16:46:55 Voltage Offset Correction: v_off_ini = 800.141 uV, v_off_fin = 799.595 uV 16:46:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.207 uVs 16:46:57 I2X Average and RMS of Measurements VT = -69.483 +- 4.324 uVs I2X = 6.393 +- 0.398 uTm^2 16:47:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:47:03 Integrated Voltage Measurement... 16:47:12 Voltage Offset Correction: v_off_ini = 795.399 uV, v_off_fin = 789.220 uV 16:47:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.798 uVs 16:47:12 Integrated Voltage Measurement... 16:47:21 Voltage Offset Correction: v_off_ini = 797.295 uV, v_off_fin = 803.799 uV 16:47:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.690 uVs 16:47:21 Integrated Voltage Measurement... 16:47:30 Voltage Offset Correction: v_off_ini = 805.226 uV, v_off_fin = 794.685 uV 16:47:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.330 uVs 16:47:30 Integrated Voltage Measurement... 16:47:39 Voltage Offset Correction: v_off_ini = 808.677 uV, v_off_fin = 814.756 uV 16:47:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.447 uVs 16:47:39 Integrated Voltage Measurement... 16:47:48 Voltage Offset Correction: v_off_ini = 816.854 uV, v_off_fin = 808.280 uV 16:47:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.739 uVs 16:47:48 Integrated Voltage Measurement... 16:47:57 Voltage Offset Correction: v_off_ini = 812.206 uV, v_off_fin = 813.684 uV 16:47:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.961 uVs 16:47:59 I2Y Average and RMS of Measurements VT = -263.494 +- 5.380 uVs I2Y = -24.241 +- 0.495 uTm^2 16:48:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:48:08 Integrated Voltage Measurement... 16:48:17 Voltage Offset Correction: v_off_ini = 817.086 uV, v_off_fin = 817.601 uV 16:48:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -104.369 uVs 16:48:17 Integrated Voltage Measurement... 16:48:26 Voltage Offset Correction: v_off_ini = 814.357 uV, v_off_fin = 814.513 uV 16:48:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.534 uVs 16:48:26 Integrated Voltage Measurement... 16:48:35 Voltage Offset Correction: v_off_ini = 815.989 uV, v_off_fin = 810.309 uV 16:48:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.745 uVs 16:48:35 Integrated Voltage Measurement... 16:48:44 Voltage Offset Correction: v_off_ini = 819.563 uV, v_off_fin = 819.516 uV 16:48:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.046 uVs 16:48:44 Integrated Voltage Measurement... 16:48:53 Voltage Offset Correction: v_off_ini = 818.592 uV, v_off_fin = 814.337 uV 16:48:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -86.228 uVs 16:48:53 Integrated Voltage Measurement... 16:49:02 Voltage Offset Correction: v_off_ini = 819.586 uV, v_off_fin = 818.611 uV 16:49:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 81.122 uVs 16:49:06 I1X Average and RMS of Measurements VT = -94.674 +- 10.012 uVs I1X = 18.937 +- 2.001 uTm 16:49:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:49:13 Integrated Voltage Measurement... 16:49:22 Voltage Offset Correction: v_off_ini = 815.356 uV, v_off_fin = 806.014 uV 16:49:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.167 uVs 16:49:22 Integrated Voltage Measurement... 16:49:31 Voltage Offset Correction: v_off_ini = 826.916 uV, v_off_fin = 829.323 uV 16:49:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.931 uVs 16:49:31 Integrated Voltage Measurement... 16:49:40 Voltage Offset Correction: v_off_ini = 841.020 uV, v_off_fin = 820.659 uV 16:49:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.493 uVs 16:49:40 Integrated Voltage Measurement... 16:49:49 Voltage Offset Correction: v_off_ini = 841.387 uV, v_off_fin = 846.834 uV 16:49:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.635 uVs 16:49:49 Integrated Voltage Measurement... 16:49:58 Voltage Offset Correction: v_off_ini = 822.153 uV, v_off_fin = 822.332 uV 16:49:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.850 uVs 16:49:58 Integrated Voltage Measurement... 16:50:07 Voltage Offset Correction: v_off_ini = 825.640 uV, v_off_fin = 846.606 uV 16:50:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.844 uVs 16:50:11 I1Y Average and RMS of Measurements VT = -205.153 +- 5.133 uVs I1Y = -41.029 +- 1.028 uTm 16:50:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:50:16 Integrated Voltage Measurement... 16:50:25 Voltage Offset Correction: v_off_ini = 842.571 uV, v_off_fin = 826.843 uV 16:50:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.972 uVs 16:50:25 Integrated Voltage Measurement... 16:50:34 Voltage Offset Correction: v_off_ini = 842.340 uV, v_off_fin = 844.877 uV 16:50:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.450 uVs 16:50:34 Integrated Voltage Measurement... 16:50:43 Voltage Offset Correction: v_off_ini = 830.910 uV, v_off_fin = 824.379 uV 16:50:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.560 uVs 16:50:43 Integrated Voltage Measurement... 16:50:52 Voltage Offset Correction: v_off_ini = 835.648 uV, v_off_fin = 835.237 uV 16:50:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.187 uVs 16:50:52 Integrated Voltage Measurement... 16:51:01 Voltage Offset Correction: v_off_ini = 831.134 uV, v_off_fin = 828.214 uV 16:51:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.266 uVs 16:51:01 Integrated Voltage Measurement... 16:51:10 Voltage Offset Correction: v_off_ini = 830.712 uV, v_off_fin = 838.667 uV 16:51:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.913 uVs 16:51:13 I2X Average and RMS of Measurements VT = -53.058 +- 2.781 uVs I2X = 4.881 +- 0.256 uTm^2 16:51:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:51:18 Integrated Voltage Measurement... 16:51:27 Voltage Offset Correction: v_off_ini = 818.649 uV, v_off_fin = 838.408 uV 16:51:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.116 uVs 16:51:27 Integrated Voltage Measurement... 16:51:36 Voltage Offset Correction: v_off_ini = 827.867 uV, v_off_fin = 820.782 uV 16:51:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.662 uVs 16:51:36 Integrated Voltage Measurement... 16:51:45 Voltage Offset Correction: v_off_ini = 814.608 uV, v_off_fin = 818.117 uV 16:51:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.115 uVs 16:51:45 Integrated Voltage Measurement... 16:51:54 Voltage Offset Correction: v_off_ini = 824.701 uV, v_off_fin = 822.546 uV 16:51:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.201 uVs 16:51:54 Integrated Voltage Measurement... 16:52:03 Voltage Offset Correction: v_off_ini = 811.102 uV, v_off_fin = 809.908 uV 16:52:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.677 uVs 16:52:03 Integrated Voltage Measurement... 16:52:12 Voltage Offset Correction: v_off_ini = 815.128 uV, v_off_fin = 825.355 uV 16:52:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.871 uVs 16:52:15 I2Y Average and RMS of Measurements VT = -262.607 +- 5.899 uVs I2Y = -24.160 +- 0.543 uTm^2 16:52:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:52:36 Integrated Voltage Measurement... 16:52:45 Voltage Offset Correction: v_off_ini = 848.200 uV, v_off_fin = 857.512 uV 16:52:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.782 uVs 16:52:45 Integrated Voltage Measurement... 16:52:54 Voltage Offset Correction: v_off_ini = 846.329 uV, v_off_fin = 842.920 uV 16:52:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.286 uVs 16:52:54 Integrated Voltage Measurement... 16:53:03 Voltage Offset Correction: v_off_ini = 837.151 uV, v_off_fin = 826.020 uV 16:53:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.413 uVs 16:53:03 Integrated Voltage Measurement... 16:53:12 Voltage Offset Correction: v_off_ini = 838.854 uV, v_off_fin = 836.401 uV 16:53:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.245 uVs 16:53:12 Integrated Voltage Measurement... 16:53:21 Voltage Offset Correction: v_off_ini = 830.603 uV, v_off_fin = 831.272 uV 16:53:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -96.050 uVs 16:53:21 Integrated Voltage Measurement... 16:53:30 Voltage Offset Correction: v_off_ini = 828.456 uV, v_off_fin = 847.637 uV 16:53:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.102 uVs 16:53:34 I1X Average and RMS of Measurements VT = -113.313 +- 9.714 uVs I1X = 22.663 +- 1.943 uTm 16:53:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:53:41 Integrated Voltage Measurement... 16:53:50 Voltage Offset Correction: v_off_ini = 834.285 uV, v_off_fin = 823.782 uV 16:53:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.882 uVs 16:53:50 Integrated Voltage Measurement... 16:53:59 Voltage Offset Correction: v_off_ini = 817.714 uV, v_off_fin = 846.807 uV 16:53:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.974 uVs 16:53:59 Integrated Voltage Measurement... 16:54:08 Voltage Offset Correction: v_off_ini = 839.905 uV, v_off_fin = 830.838 uV 16:54:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.102 uVs 16:54:08 Integrated Voltage Measurement... 16:54:17 Voltage Offset Correction: v_off_ini = 862.549 uV, v_off_fin = 876.613 uV 16:54:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.731 uVs 16:54:17 Integrated Voltage Measurement... 16:54:26 Voltage Offset Correction: v_off_ini = 856.535 uV, v_off_fin = 839.888 uV 16:54:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.524 uVs 16:54:26 Integrated Voltage Measurement... 16:54:35 Voltage Offset Correction: v_off_ini = 838.794 uV, v_off_fin = 852.553 uV 16:54:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.041 uVs 16:54:39 I1Y Average and RMS of Measurements VT = -168.709 +- 5.485 uVs I1Y = -33.742 +- 1.097 uTm 16:54:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:54:47 Integrated Voltage Measurement... 16:54:56 Voltage Offset Correction: v_off_ini = 819.956 uV, v_off_fin = 823.423 uV 16:54:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.177 uVs 16:54:56 Integrated Voltage Measurement... 16:55:05 Voltage Offset Correction: v_off_ini = 841.631 uV, v_off_fin = 852.148 uV 16:55:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.129 uVs 16:55:05 Integrated Voltage Measurement... 16:55:14 Voltage Offset Correction: v_off_ini = 855.874 uV, v_off_fin = 837.457 uV 16:55:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.129 uVs 16:55:14 Integrated Voltage Measurement... 16:55:23 Voltage Offset Correction: v_off_ini = 836.501 uV, v_off_fin = 838.117 uV 16:55:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.822 uVs 16:55:23 Integrated Voltage Measurement... 16:55:32 Voltage Offset Correction: v_off_ini = 822.243 uV, v_off_fin = 829.622 uV 16:55:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.390 uVs 16:55:32 Integrated Voltage Measurement... 16:55:41 Voltage Offset Correction: v_off_ini = 822.735 uV, v_off_fin = 829.456 uV 16:55:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.055 uVs 16:55:44 I2X Average and RMS of Measurements VT = -103.450 +- 4.013 uVs I2X = 9.517 +- 0.369 uTm^2 16:55:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:55:51 Integrated Voltage Measurement... 16:56:00 Voltage Offset Correction: v_off_ini = 838.347 uV, v_off_fin = 829.719 uV 16:56:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.215 uVs 16:56:00 Integrated Voltage Measurement... 16:56:09 Voltage Offset Correction: v_off_ini = 815.691 uV, v_off_fin = 830.013 uV 16:56:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.028 uVs 16:56:09 Integrated Voltage Measurement... 16:56:18 Voltage Offset Correction: v_off_ini = 830.795 uV, v_off_fin = 836.522 uV 16:56:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.791 uVs 16:56:18 Integrated Voltage Measurement... 16:56:27 Voltage Offset Correction: v_off_ini = 841.984 uV, v_off_fin = 841.538 uV 16:56:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.484 uVs 16:56:27 Integrated Voltage Measurement... 16:56:36 Voltage Offset Correction: v_off_ini = 842.291 uV, v_off_fin = 840.553 uV 16:56:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.633 uVs 16:56:37 Integrated Voltage Measurement... 16:56:45 Voltage Offset Correction: v_off_ini = 831.695 uV, v_off_fin = 840.124 uV 16:56:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.381 uVs 16:56:48 I2Y Average and RMS of Measurements VT = -209.922 +- 4.804 uVs I2Y = -19.313 +- 0.442 uTm^2 16:56:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:56:57 Integrated Voltage Measurement... 16:57:06 Voltage Offset Correction: v_off_ini = 839.928 uV, v_off_fin = 811.645 uV 16:57:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.681 uVs 16:57:06 Integrated Voltage Measurement... 16:57:15 Voltage Offset Correction: v_off_ini = 828.354 uV, v_off_fin = 840.869 uV 16:57:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.186 uVs 16:57:15 Integrated Voltage Measurement... 16:57:24 Voltage Offset Correction: v_off_ini = 829.931 uV, v_off_fin = 832.517 uV 16:57:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.042 uVs 16:57:24 Integrated Voltage Measurement... 16:57:33 Voltage Offset Correction: v_off_ini = 825.981 uV, v_off_fin = 832.901 uV 16:57:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.570 uVs 16:57:33 Integrated Voltage Measurement... 16:57:42 Voltage Offset Correction: v_off_ini = 833.802 uV, v_off_fin = 831.645 uV 16:57:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.546 uVs 16:57:42 Integrated Voltage Measurement... 16:57:51 Voltage Offset Correction: v_off_ini = 816.572 uV, v_off_fin = 826.110 uV 16:57:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.425 uVs 16:57:55 I1X Average and RMS of Measurements VT = -116.908 +- 5.399 uVs I1X = 23.382 +- 1.080 uTm 16:57:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:58:02 Integrated Voltage Measurement... 16:58:11 Voltage Offset Correction: v_off_ini = 829.141 uV, v_off_fin = 818.543 uV 16:58:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.377 uVs 16:58:11 Integrated Voltage Measurement... 16:58:20 Voltage Offset Correction: v_off_ini = 837.540 uV, v_off_fin = 837.584 uV 16:58:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.123 uVs 16:58:20 Integrated Voltage Measurement... 16:58:29 Voltage Offset Correction: v_off_ini = 843.241 uV, v_off_fin = 831.142 uV 16:58:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.142 uVs 16:58:29 Integrated Voltage Measurement... 16:58:38 Voltage Offset Correction: v_off_ini = 841.734 uV, v_off_fin = 852.403 uV 16:58:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.932 uVs 16:58:38 Integrated Voltage Measurement... 16:58:47 Voltage Offset Correction: v_off_ini = 832.887 uV, v_off_fin = 836.640 uV 16:58:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.337 uVs 16:58:47 Integrated Voltage Measurement... 16:58:56 Voltage Offset Correction: v_off_ini = 841.729 uV, v_off_fin = 850.165 uV 16:58:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.165 uVs 16:59:00 I1Y Average and RMS of Measurements VT = -183.679 +- 3.950 uVs I1Y = -36.736 +- 0.790 uTm 16:59:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:59:08 Integrated Voltage Measurement... 16:59:17 Voltage Offset Correction: v_off_ini = 840.057 uV, v_off_fin = 832.178 uV 16:59:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.520 uVs 16:59:17 Integrated Voltage Measurement... 16:59:26 Voltage Offset Correction: v_off_ini = 851.162 uV, v_off_fin = 852.080 uV 16:59:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.174 uVs 16:59:26 Integrated Voltage Measurement... 16:59:35 Voltage Offset Correction: v_off_ini = 842.447 uV, v_off_fin = 845.041 uV 16:59:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.166 uVs 16:59:35 Integrated Voltage Measurement... 16:59:44 Voltage Offset Correction: v_off_ini = 859.970 uV, v_off_fin = 856.009 uV 16:59:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.140 uVs 16:59:44 Integrated Voltage Measurement... 16:59:53 Voltage Offset Correction: v_off_ini = 851.429 uV, v_off_fin = 849.824 uV 16:59:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.226 uVs 16:59:53 Integrated Voltage Measurement... 17:00:02 Voltage Offset Correction: v_off_ini = 861.424 uV, v_off_fin = 859.969 uV 17:00:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.620 uVs 17:00:05 I2X Average and RMS of Measurements VT = -81.808 +- 4.687 uVs I2X = 7.526 +- 0.431 uTm^2 17:00:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:00:12 Integrated Voltage Measurement... 17:00:21 Voltage Offset Correction: v_off_ini = 871.249 uV, v_off_fin = 868.973 uV 17:00:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.814 uVs 17:00:21 Integrated Voltage Measurement... 17:00:30 Voltage Offset Correction: v_off_ini = 856.432 uV, v_off_fin = 853.568 uV 17:00:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.362 uVs 17:00:30 Integrated Voltage Measurement... 17:00:39 Voltage Offset Correction: v_off_ini = 865.304 uV, v_off_fin = 868.492 uV 17:00:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.936 uVs 17:00:39 Integrated Voltage Measurement... 17:00:48 Voltage Offset Correction: v_off_ini = 874.760 uV, v_off_fin = 857.841 uV 17:00:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.511 uVs 17:00:49 Integrated Voltage Measurement... 17:00:58 Voltage Offset Correction: v_off_ini = 863.989 uV, v_off_fin = 861.267 uV 17:00:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.066 uVs 17:00:58 Integrated Voltage Measurement... 17:01:07 Voltage Offset Correction: v_off_ini = 857.109 uV, v_off_fin = 861.179 uV 17:01:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.984 uVs 17:01:09 I2Y Average and RMS of Measurements VT = -228.446 +- 6.522 uVs I2Y = -21.017 +- 0.600 uTm^2 17:01:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:18 Integrated Voltage Measurement... 17:01:27 Voltage Offset Correction: v_off_ini = 854.016 uV, v_off_fin = 854.200 uV 17:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -129.076 uVs 17:01:27 Integrated Voltage Measurement... 17:01:36 Voltage Offset Correction: v_off_ini = 857.558 uV, v_off_fin = 877.980 uV 17:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.914 uVs 17:01:36 Integrated Voltage Measurement... 17:01:45 Voltage Offset Correction: v_off_ini = 870.469 uV, v_off_fin = 862.633 uV 17:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.174 uVs 17:01:45 Integrated Voltage Measurement... 17:01:54 Voltage Offset Correction: v_off_ini = 862.266 uV, v_off_fin = 859.310 uV 17:01:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.816 uVs 17:01:54 Integrated Voltage Measurement... 17:02:03 Voltage Offset Correction: v_off_ini = 852.740 uV, v_off_fin = 854.658 uV 17:02:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.905 uVs 17:02:03 Integrated Voltage Measurement... 17:02:12 Voltage Offset Correction: v_off_ini = 863.433 uV, v_off_fin = 872.675 uV 17:02:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.313 uVs 17:02:16 I1X Average and RMS of Measurements VT = -113.866 +- 7.166 uVs I1X = 22.774 +- 1.434 uTm 17:02:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:23 Integrated Voltage Measurement... 17:02:32 Voltage Offset Correction: v_off_ini = 861.061 uV, v_off_fin = 852.440 uV 17:02:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.653 uVs 17:02:32 Integrated Voltage Measurement... 17:02:41 Voltage Offset Correction: v_off_ini = 859.323 uV, v_off_fin = 869.316 uV 17:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.394 uVs 17:02:41 Integrated Voltage Measurement... 17:02:50 Voltage Offset Correction: v_off_ini = 869.407 uV, v_off_fin = 868.593 uV 17:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.819 uVs 17:02:50 Integrated Voltage Measurement... 17:02:59 Voltage Offset Correction: v_off_ini = 868.326 uV, v_off_fin = 877.763 uV 17:02:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.256 uVs 17:02:59 Integrated Voltage Measurement... 17:03:08 Voltage Offset Correction: v_off_ini = 872.467 uV, v_off_fin = 874.959 uV 17:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.164 uVs 17:03:08 Integrated Voltage Measurement... 17:03:17 Voltage Offset Correction: v_off_ini = 875.569 uV, v_off_fin = 896.019 uV 17:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.698 uVs 17:03:21 I1Y Average and RMS of Measurements VT = -196.997 +- 7.398 uVs I1Y = -39.399 +- 1.480 uTm 17:03:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:29 Integrated Voltage Measurement... 17:03:38 Voltage Offset Correction: v_off_ini = 861.209 uV, v_off_fin = 859.353 uV 17:03:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -115.254 uVs 17:03:38 Integrated Voltage Measurement... 17:03:47 Voltage Offset Correction: v_off_ini = 855.697 uV, v_off_fin = 862.026 uV 17:03:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.202 uVs 17:03:47 Integrated Voltage Measurement... 17:03:56 Voltage Offset Correction: v_off_ini = 855.871 uV, v_off_fin = 838.816 uV 17:03:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.442 uVs 17:03:56 Integrated Voltage Measurement... 17:04:05 Voltage Offset Correction: v_off_ini = 865.058 uV, v_off_fin = 871.293 uV 17:04:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.597 uVs 17:04:05 Integrated Voltage Measurement... 17:04:14 Voltage Offset Correction: v_off_ini = 876.724 uV, v_off_fin = 864.285 uV 17:04:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.214 uVs 17:04:14 Integrated Voltage Measurement... 17:04:23 Voltage Offset Correction: v_off_ini = 863.706 uV, v_off_fin = 871.524 uV 17:04:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.171 uVs 17:04:26 I2X Average and RMS of Measurements VT = -84.980 +- 13.565 uVs I2X = 7.818 +- 1.248 uTm^2 17:04:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:33 Integrated Voltage Measurement... 17:04:42 Voltage Offset Correction: v_off_ini = 851.459 uV, v_off_fin = 849.352 uV 17:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.822 uVs 17:04:43 Integrated Voltage Measurement... 17:04:52 Voltage Offset Correction: v_off_ini = 852.328 uV, v_off_fin = 840.562 uV 17:04:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.062 uVs 17:04:52 Integrated Voltage Measurement... 17:05:01 Voltage Offset Correction: v_off_ini = 852.612 uV, v_off_fin = 845.386 uV 17:05:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.516 uVs 17:05:01 Integrated Voltage Measurement... 17:05:10 Voltage Offset Correction: v_off_ini = 853.832 uV, v_off_fin = 859.905 uV 17:05:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.123 uVs 17:05:10 Integrated Voltage Measurement... 17:05:19 Voltage Offset Correction: v_off_ini = 845.519 uV, v_off_fin = 854.839 uV 17:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.560 uVs 17:05:19 Integrated Voltage Measurement... 17:05:28 Voltage Offset Correction: v_off_ini = 863.698 uV, v_off_fin = 861.121 uV 17:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.068 uVs 17:05:30 I2Y Average and RMS of Measurements VT = -240.025 +- 11.317 uVs I2Y = -22.082 +- 1.041 uTm^2 17:05:35 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:05:39 Integrated Voltage Measurement... 17:05:48 Voltage Offset Correction: v_off_ini = 852.959 uV, v_off_fin = 856.778 uV 17:05:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.040 uVs 17:05:48 Integrated Voltage Measurement... 17:05:57 Voltage Offset Correction: v_off_ini = 849.160 uV, v_off_fin = 854.004 uV 17:05:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.817 uVs 17:05:57 Integrated Voltage Measurement... 17:06:06 Voltage Offset Correction: v_off_ini = 853.284 uV, v_off_fin = 858.383 uV 17:06:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.446 uVs 17:06:06 Integrated Voltage Measurement... 17:06:15 Voltage Offset Correction: v_off_ini = 864.000 uV, v_off_fin = 866.642 uV 17:06:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.337 uVs 17:06:15 Integrated Voltage Measurement... 17:06:24 Voltage Offset Correction: v_off_ini = 864.086 uV, v_off_fin = 846.913 uV 17:06:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.780 uVs 17:06:24 Integrated Voltage Measurement... 17:06:33 Voltage Offset Correction: v_off_ini = 849.992 uV, v_off_fin = 863.453 uV 17:06:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.860 uVs 17:06:37 I1X Average and RMS of Measurements VT = -113.047 +- 6.498 uVs I1X = 22.610 +- 1.300 uTm 17:06:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:06:44 Integrated Voltage Measurement... 17:06:53 Voltage Offset Correction: v_off_ini = 853.768 uV, v_off_fin = 843.621 uV 17:06:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -221.977 uVs 17:06:53 Integrated Voltage Measurement... 17:07:02 Voltage Offset Correction: v_off_ini = 852.373 uV, v_off_fin = 862.068 uV 17:07:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.764 uVs 17:07:02 Integrated Voltage Measurement... 17:07:11 Voltage Offset Correction: v_off_ini = 847.321 uV, v_off_fin = 838.157 uV 17:07:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.925 uVs 17:07:11 Integrated Voltage Measurement... 17:07:20 Voltage Offset Correction: v_off_ini = 848.247 uV, v_off_fin = 872.954 uV 17:07:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.319 uVs 17:07:20 Integrated Voltage Measurement... 17:07:29 Voltage Offset Correction: v_off_ini = 860.688 uV, v_off_fin = 846.738 uV 17:07:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.370 uVs 17:07:29 Integrated Voltage Measurement... 17:07:38 Voltage Offset Correction: v_off_ini = 861.477 uV, v_off_fin = 866.154 uV 17:07:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.688 uVs 17:07:42 I1Y Average and RMS of Measurements VT = -213.341 +- 8.863 uVs I1Y = -42.669 +- 1.773 uTm 17:07:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:07:50 Integrated Voltage Measurement... 17:07:59 Voltage Offset Correction: v_off_ini = 873.322 uV, v_off_fin = 861.168 uV 17:07:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.210 uVs 17:07:59 Integrated Voltage Measurement... 17:08:08 Voltage Offset Correction: v_off_ini = 868.702 uV, v_off_fin = 874.205 uV 17:08:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.169 uVs 17:08:08 Integrated Voltage Measurement... 17:08:17 Voltage Offset Correction: v_off_ini = 866.523 uV, v_off_fin = 867.788 uV 17:08:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.522 uVs 17:08:17 Integrated Voltage Measurement... 17:08:26 Voltage Offset Correction: v_off_ini = 867.407 uV, v_off_fin = 875.757 uV 17:08:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.516 uVs 17:08:26 Integrated Voltage Measurement... 17:08:35 Voltage Offset Correction: v_off_ini = 863.537 uV, v_off_fin = 863.814 uV 17:08:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.097 uVs 17:08:35 Integrated Voltage Measurement... 17:08:44 Voltage Offset Correction: v_off_ini = 875.073 uV, v_off_fin = 891.393 uV 17:08:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.791 uVs 17:08:47 I2X Average and RMS of Measurements VT = -83.884 +- 0.939 uVs I2X = 7.717 +- 0.086 uTm^2 17:08:52 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:08:55 Integrated Voltage Measurement... 17:09:04 Voltage Offset Correction: v_off_ini = 887.653 uV, v_off_fin = 890.499 uV 17:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.433 uVs 17:09:04 Integrated Voltage Measurement... 17:09:13 Voltage Offset Correction: v_off_ini = 885.281 uV, v_off_fin = 857.131 uV 17:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.346 uVs 17:09:13 Integrated Voltage Measurement... 17:09:22 Voltage Offset Correction: v_off_ini = 868.084 uV, v_off_fin = 861.497 uV 17:09:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.001 uVs 17:09:22 Integrated Voltage Measurement... 17:09:31 Voltage Offset Correction: v_off_ini = 853.921 uV, v_off_fin = 874.383 uV 17:09:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.646 uVs 17:09:31 Integrated Voltage Measurement... 17:09:40 Voltage Offset Correction: v_off_ini = 881.339 uV, v_off_fin = 874.632 uV 17:09:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.272 uVs 17:09:40 Integrated Voltage Measurement... 17:09:49 Voltage Offset Correction: v_off_ini = 870.405 uV, v_off_fin = 881.937 uV 17:09:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.950 uVs 17:09:51 I2Y Average and RMS of Measurements VT = -259.774 +- 2.569 uVs I2Y = -23.899 +- 0.236 uTm^2 17:09:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:10:00 Integrated Voltage Measurement... 17:10:09 Voltage Offset Correction: v_off_ini = 868.762 uV, v_off_fin = 863.149 uV 17:10:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -127.974 uVs 17:10:09 Integrated Voltage Measurement... 17:10:18 Voltage Offset Correction: v_off_ini = 852.801 uV, v_off_fin = 852.484 uV 17:10:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.701 uVs 17:10:18 Integrated Voltage Measurement... 17:10:27 Voltage Offset Correction: v_off_ini = 864.879 uV, v_off_fin = 850.413 uV 17:10:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.736 uVs 17:10:27 Integrated Voltage Measurement... 17:10:36 Voltage Offset Correction: v_off_ini = 863.151 uV, v_off_fin = 861.331 uV 17:10:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.037 uVs 17:10:36 Integrated Voltage Measurement... 17:10:45 Voltage Offset Correction: v_off_ini = 862.530 uV, v_off_fin = 858.434 uV 17:10:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.064 uVs 17:10:45 Integrated Voltage Measurement... 17:10:54 Voltage Offset Correction: v_off_ini = 859.048 uV, v_off_fin = 863.000 uV 17:10:54 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.096 uVs 17:10:59 I1X Average and RMS of Measurements VT = -111.101 +- 2.457 uVs I1X = 22.222 +- 0.493 uTm 17:11:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:11:05 Integrated Voltage Measurement... 17:11:14 Voltage Offset Correction: v_off_ini = 868.060 uV, v_off_fin = 850.650 uV 17:11:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.294 uVs 17:11:14 Integrated Voltage Measurement... 17:11:23 Voltage Offset Correction: v_off_ini = 872.331 uV, v_off_fin = 871.896 uV 17:11:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.330 uVs 17:11:23 Integrated Voltage Measurement... 17:11:32 Voltage Offset Correction: v_off_ini = 863.384 uV, v_off_fin = 857.544 uV 17:11:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.757 uVs 17:11:32 Integrated Voltage Measurement... 17:11:41 Voltage Offset Correction: v_off_ini = 857.728 uV, v_off_fin = 848.597 uV 17:11:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.245 uVs 17:11:41 Integrated Voltage Measurement... 17:11:50 Voltage Offset Correction: v_off_ini = 860.385 uV, v_off_fin = 836.957 uV 17:11:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.059 uVs 17:11:50 Integrated Voltage Measurement... 17:11:59 Voltage Offset Correction: v_off_ini = 847.169 uV, v_off_fin = 860.073 uV 17:11:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.208 uVs 17:12:04 I1Y Average and RMS of Measurements VT = -212.482 +- 8.816 uVs I1Y = -42.496 +- 1.763 uTm 17:12:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:12:11 Integrated Voltage Measurement... 17:12:20 Voltage Offset Correction: v_off_ini = 859.805 uV, v_off_fin = 842.706 uV 17:12:20 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -68.379 uVs 17:12:20 Integrated Voltage Measurement... 17:12:29 Voltage Offset Correction: v_off_ini = 862.525 uV, v_off_fin = 884.800 uV 17:12:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.485 uVs 17:12:29 Integrated Voltage Measurement... 17:12:38 Voltage Offset Correction: v_off_ini = 889.883 uV, v_off_fin = 865.663 uV 17:12:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.674 uVs 17:12:38 Integrated Voltage Measurement... 17:12:47 Voltage Offset Correction: v_off_ini = 874.086 uV, v_off_fin = 884.552 uV 17:12:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.151 uVs 17:12:47 Integrated Voltage Measurement... 17:12:56 Voltage Offset Correction: v_off_ini = 891.491 uV, v_off_fin = 877.580 uV 17:12:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.841 uVs 17:12:57 Integrated Voltage Measurement... 17:13:05 Voltage Offset Correction: v_off_ini = 885.036 uV, v_off_fin = 884.966 uV 17:13:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.136 uVs 17:13:08 I2X Average and RMS of Measurements VT = -76.778 +- 6.119 uVs I2X = 7.063 +- 0.563 uTm^2 17:13:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:13:16 Integrated Voltage Measurement... 17:13:25 Voltage Offset Correction: v_off_ini = 878.042 uV, v_off_fin = 875.172 uV 17:13:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.275 uVs 17:13:25 Integrated Voltage Measurement... 17:13:34 Voltage Offset Correction: v_off_ini = 876.933 uV, v_off_fin = 864.139 uV 17:13:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.228 uVs 17:13:34 Integrated Voltage Measurement... 17:13:43 Voltage Offset Correction: v_off_ini = 865.590 uV, v_off_fin = 857.161 uV 17:13:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -270.425 uVs 17:13:43 Integrated Voltage Measurement... 17:13:52 Voltage Offset Correction: v_off_ini = 871.777 uV, v_off_fin = 855.506 uV 17:13:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.257 uVs 17:13:52 Integrated Voltage Measurement... 17:14:01 Voltage Offset Correction: v_off_ini = 865.129 uV, v_off_fin = 869.431 uV 17:14:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.872 uVs 17:14:01 Integrated Voltage Measurement... 17:14:10 Voltage Offset Correction: v_off_ini = 866.394 uV, v_off_fin = 862.607 uV 17:14:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.983 uVs 17:14:12 I2Y Average and RMS of Measurements VT = -264.506 +- 5.954 uVs I2Y = -24.335 +- 0.548 uTm^2 17:14:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:14:24 Integrated Voltage Measurement... 17:14:33 Voltage Offset Correction: v_off_ini = 864.436 uV, v_off_fin = 861.122 uV 17:14:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.524 uVs 17:14:33 Integrated Voltage Measurement... 17:14:42 Voltage Offset Correction: v_off_ini = 846.912 uV, v_off_fin = 853.641 uV 17:14:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.656 uVs 17:14:42 Integrated Voltage Measurement... 17:14:51 Voltage Offset Correction: v_off_ini = 848.422 uV, v_off_fin = 855.497 uV 17:14:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.954 uVs 17:14:51 Integrated Voltage Measurement... 17:15:00 Voltage Offset Correction: v_off_ini = 855.533 uV, v_off_fin = 855.530 uV 17:15:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.281 uVs 17:15:00 Integrated Voltage Measurement... 17:15:09 Voltage Offset Correction: v_off_ini = 858.740 uV, v_off_fin = 855.032 uV 17:15:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.535 uVs 17:15:09 Integrated Voltage Measurement... 17:15:18 Voltage Offset Correction: v_off_ini = 857.000 uV, v_off_fin = 847.424 uV 17:15:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.544 uVs 17:15:23 I1X Average and RMS of Measurements VT = -119.916 +- 13.963 uVs I1X = 23.983 +- 2.792 uTm 17:15:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:15:29 Integrated Voltage Measurement... 17:15:38 Voltage Offset Correction: v_off_ini = 847.299 uV, v_off_fin = 837.768 uV 17:15:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.037 uVs 17:15:38 Integrated Voltage Measurement... 17:15:47 Voltage Offset Correction: v_off_ini = 847.615 uV, v_off_fin = 868.103 uV 17:15:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.174 uVs 17:15:47 Integrated Voltage Measurement... 17:15:56 Voltage Offset Correction: v_off_ini = 863.645 uV, v_off_fin = 837.410 uV 17:15:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.097 uVs 17:15:56 Integrated Voltage Measurement... 17:16:05 Voltage Offset Correction: v_off_ini = 854.800 uV, v_off_fin = 863.173 uV 17:16:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.473 uVs 17:16:05 Integrated Voltage Measurement... 17:16:14 Voltage Offset Correction: v_off_ini = 845.134 uV, v_off_fin = 839.655 uV 17:16:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.946 uVs 17:16:14 Integrated Voltage Measurement... 17:16:23 Voltage Offset Correction: v_off_ini = 842.784 uV, v_off_fin = 862.732 uV 17:16:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.034 uVs 17:16:28 I1Y Average and RMS of Measurements VT = -198.127 +- 1.403 uVs I1Y = -39.625 +- 0.281 uTm 17:16:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:16:33 Integrated Voltage Measurement... 17:16:42 Voltage Offset Correction: v_off_ini = 867.553 uV, v_off_fin = 855.235 uV 17:16:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.304 uVs 17:16:42 Integrated Voltage Measurement... 17:16:51 Voltage Offset Correction: v_off_ini = 863.369 uV, v_off_fin = 869.762 uV 17:16:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.407 uVs 17:16:51 Integrated Voltage Measurement... 17:17:00 Voltage Offset Correction: v_off_ini = 850.047 uV, v_off_fin = 835.255 uV 17:17:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.882 uVs 17:17:00 Integrated Voltage Measurement... 17:17:09 Voltage Offset Correction: v_off_ini = 860.435 uV, v_off_fin = 856.231 uV 17:17:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.307 uVs 17:17:09 Integrated Voltage Measurement... 17:17:18 Voltage Offset Correction: v_off_ini = 854.453 uV, v_off_fin = 847.406 uV 17:17:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.605 uVs 17:17:18 Integrated Voltage Measurement... 17:17:27 Voltage Offset Correction: v_off_ini = 854.476 uV, v_off_fin = 868.572 uV 17:17:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.781 uVs 17:17:29 I2X Average and RMS of Measurements VT = -93.714 +- 9.040 uVs I2X = 8.622 +- 0.832 uTm^2 17:17:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:17:35 Integrated Voltage Measurement... 17:17:44 Voltage Offset Correction: v_off_ini = 851.024 uV, v_off_fin = 850.513 uV 17:17:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.864 uVs 17:17:44 Integrated Voltage Measurement... 17:17:53 Voltage Offset Correction: v_off_ini = 870.895 uV, v_off_fin = 863.929 uV 17:17:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.199 uVs 17:17:53 Integrated Voltage Measurement... 17:18:02 Voltage Offset Correction: v_off_ini = 875.227 uV, v_off_fin = 861.396 uV 17:18:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.672 uVs 17:18:02 Integrated Voltage Measurement... 17:18:11 Voltage Offset Correction: v_off_ini = 863.585 uV, v_off_fin = 871.434 uV 17:18:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.340 uVs 17:18:11 Integrated Voltage Measurement... 17:18:20 Voltage Offset Correction: v_off_ini = 867.335 uV, v_off_fin = 867.457 uV 17:18:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.062 uVs 17:18:20 Integrated Voltage Measurement... 17:18:29 Voltage Offset Correction: v_off_ini = 860.749 uV, v_off_fin = 862.580 uV 17:18:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.677 uVs 17:18:31 I2Y Average and RMS of Measurements VT = -250.803 +- 4.519 uVs I2Y = -23.074 +- 0.416 uTm^2 17:18:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:18:40 Integrated Voltage Measurement... 17:18:49 Voltage Offset Correction: v_off_ini = 845.592 uV, v_off_fin = 836.782 uV 17:18:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.533 uVs 17:18:49 Integrated Voltage Measurement... 17:18:58 Voltage Offset Correction: v_off_ini = 854.576 uV, v_off_fin = 854.427 uV 17:18:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.077 uVs 17:18:58 Integrated Voltage Measurement... 17:19:07 Voltage Offset Correction: v_off_ini = 862.044 uV, v_off_fin = 875.814 uV 17:19:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -128.686 uVs 17:19:07 Integrated Voltage Measurement... 17:19:16 Voltage Offset Correction: v_off_ini = 849.805 uV, v_off_fin = 858.354 uV 17:19:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.470 uVs 17:19:16 Integrated Voltage Measurement... 17:19:25 Voltage Offset Correction: v_off_ini = 843.779 uV, v_off_fin = 846.045 uV 17:19:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.263 uVs 17:19:25 Integrated Voltage Measurement... 17:19:34 Voltage Offset Correction: v_off_ini = 861.365 uV, v_off_fin = 865.190 uV 17:19:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 102.494 uVs 17:19:38 I1X Average and RMS of Measurements VT = -117.087 +- 5.830 uVs I1X = 23.419 +- 1.166 uTm 17:19:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:19:45 Integrated Voltage Measurement... 17:19:54 Voltage Offset Correction: v_off_ini = 842.177 uV, v_off_fin = 828.254 uV 17:19:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.565 uVs 17:19:54 Integrated Voltage Measurement... 17:20:03 Voltage Offset Correction: v_off_ini = 821.264 uV, v_off_fin = 810.386 uV 17:20:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.611 uVs 17:20:03 Integrated Voltage Measurement... 17:20:12 Voltage Offset Correction: v_off_ini = 813.167 uV, v_off_fin = 792.669 uV 17:20:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.382 uVs 17:20:12 Integrated Voltage Measurement... 17:20:21 Voltage Offset Correction: v_off_ini = 817.055 uV, v_off_fin = 832.894 uV 17:20:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.832 uVs 17:20:21 Integrated Voltage Measurement... 17:20:30 Voltage Offset Correction: v_off_ini = 815.911 uV, v_off_fin = 814.519 uV 17:20:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.323 uVs 17:20:30 Integrated Voltage Measurement... 17:20:39 Voltage Offset Correction: v_off_ini = 811.023 uV, v_off_fin = 822.564 uV 17:20:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.928 uVs 17:20:43 I1Y Average and RMS of Measurements VT = -199.107 +- 3.939 uVs I1Y = -39.821 +- 0.788 uTm 17:20:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:20:48 Integrated Voltage Measurement... 17:20:57 Voltage Offset Correction: v_off_ini = 814.347 uV, v_off_fin = 799.334 uV 17:20:57 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.209 uVs 17:20:57 Integrated Voltage Measurement... 17:21:06 Voltage Offset Correction: v_off_ini = 811.765 uV, v_off_fin = 827.187 uV 17:21:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.726 uVs 17:21:06 Integrated Voltage Measurement... 17:21:15 Voltage Offset Correction: v_off_ini = 807.370 uV, v_off_fin = 814.874 uV 17:21:15 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.744 uVs 17:21:15 Integrated Voltage Measurement... 17:21:24 Voltage Offset Correction: v_off_ini = 828.012 uV, v_off_fin = 826.827 uV 17:21:24 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 84.713 uVs 17:21:24 Integrated Voltage Measurement... 17:21:33 Voltage Offset Correction: v_off_ini = 825.620 uV, v_off_fin = 811.098 uV 17:21:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.447 uVs 17:21:33 Integrated Voltage Measurement... 17:21:42 Voltage Offset Correction: v_off_ini = 822.264 uV, v_off_fin = 824.059 uV 17:21:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 91.521 uVs 17:21:45 I2X Average and RMS of Measurements VT = -87.893 +- 3.854 uVs I2X = 8.087 +- 0.354 uTm^2 17:21:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:21:50 Integrated Voltage Measurement... 17:21:59 Voltage Offset Correction: v_off_ini = 818.562 uV, v_off_fin = 817.361 uV 17:21:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.232 uVs 17:21:59 Integrated Voltage Measurement... 17:22:08 Voltage Offset Correction: v_off_ini = 821.957 uV, v_off_fin = 821.828 uV 17:22:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.478 uVs 17:22:08 Integrated Voltage Measurement... 17:22:17 Voltage Offset Correction: v_off_ini = 835.899 uV, v_off_fin = 836.373 uV 17:22:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.825 uVs 17:22:17 Integrated Voltage Measurement... 17:22:26 Voltage Offset Correction: v_off_ini = 829.797 uV, v_off_fin = 824.482 uV 17:22:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.759 uVs 17:22:26 Integrated Voltage Measurement... 17:22:35 Voltage Offset Correction: v_off_ini = 825.428 uV, v_off_fin = 824.152 uV 17:22:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.198 uVs 17:22:35 Integrated Voltage Measurement... 17:22:44 Voltage Offset Correction: v_off_ini = 843.946 uV, v_off_fin = 838.592 uV 17:22:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.854 uVs 17:22:47 I2Y Average and RMS of Measurements VT = -248.724 +- 5.101 uVs I2Y = -22.883 +- 0.469 uTm^2 17:22:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:55 Integrated Voltage Measurement... 17:23:04 Voltage Offset Correction: v_off_ini = 860.630 uV, v_off_fin = 851.762 uV 17:23:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -119.237 uVs 17:23:04 Integrated Voltage Measurement... 17:23:13 Voltage Offset Correction: v_off_ini = 839.430 uV, v_off_fin = 849.480 uV 17:23:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.300 uVs 17:23:13 Integrated Voltage Measurement... 17:23:22 Voltage Offset Correction: v_off_ini = 845.797 uV, v_off_fin = 853.433 uV 17:23:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.373 uVs 17:23:22 Integrated Voltage Measurement... 17:23:31 Voltage Offset Correction: v_off_ini = 861.311 uV, v_off_fin = 848.589 uV 17:23:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.098 uVs 17:23:31 Integrated Voltage Measurement... 17:23:40 Voltage Offset Correction: v_off_ini = 845.918 uV, v_off_fin = 844.036 uV 17:23:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.620 uVs 17:23:40 Integrated Voltage Measurement... 17:23:49 Voltage Offset Correction: v_off_ini = 841.092 uV, v_off_fin = 848.802 uV 17:23:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.815 uVs 17:23:53 I1X Average and RMS of Measurements VT = -104.574 +- 4.777 uVs I1X = 20.916 +- 0.956 uTm 17:23:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:00 Integrated Voltage Measurement... 17:24:09 Voltage Offset Correction: v_off_ini = 833.621 uV, v_off_fin = 840.679 uV 17:24:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.878 uVs 17:24:09 Integrated Voltage Measurement... 17:24:18 Voltage Offset Correction: v_off_ini = 846.534 uV, v_off_fin = 859.860 uV 17:24:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.242 uVs 17:24:18 Integrated Voltage Measurement... 17:24:27 Voltage Offset Correction: v_off_ini = 851.739 uV, v_off_fin = 847.649 uV 17:24:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.786 uVs 17:24:27 Integrated Voltage Measurement... 17:24:36 Voltage Offset Correction: v_off_ini = 852.356 uV, v_off_fin = 863.342 uV 17:24:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.544 uVs 17:24:36 Integrated Voltage Measurement... 17:24:45 Voltage Offset Correction: v_off_ini = 840.139 uV, v_off_fin = 831.511 uV 17:24:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.011 uVs 17:24:45 Integrated Voltage Measurement... 17:24:54 Voltage Offset Correction: v_off_ini = 834.714 uV, v_off_fin = 848.774 uV 17:24:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.065 uVs 17:24:58 I1Y Average and RMS of Measurements VT = -188.254 +- 1.688 uVs I1Y = -37.651 +- 0.338 uTm 17:25:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:25:03 Integrated Voltage Measurement... 17:25:12 Voltage Offset Correction: v_off_ini = 827.338 uV, v_off_fin = 828.591 uV 17:25:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.313 uVs 17:25:12 Integrated Voltage Measurement... 17:25:21 Voltage Offset Correction: v_off_ini = 840.592 uV, v_off_fin = 857.655 uV 17:25:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.669 uVs 17:25:22 Integrated Voltage Measurement... 17:25:31 Voltage Offset Correction: v_off_ini = 842.656 uV, v_off_fin = 842.393 uV 17:25:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.860 uVs 17:25:31 Integrated Voltage Measurement... 17:25:40 Voltage Offset Correction: v_off_ini = 848.228 uV, v_off_fin = 845.705 uV 17:25:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.344 uVs 17:25:40 Integrated Voltage Measurement... 17:25:49 Voltage Offset Correction: v_off_ini = 852.108 uV, v_off_fin = 833.001 uV 17:25:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.499 uVs 17:25:49 Integrated Voltage Measurement... 17:25:58 Voltage Offset Correction: v_off_ini = 835.742 uV, v_off_fin = 847.971 uV 17:25:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.904 uVs 17:26:00 I2X Average and RMS of Measurements VT = -82.432 +- 3.837 uVs I2X = 7.584 +- 0.353 uTm^2 17:26:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:26:05 Integrated Voltage Measurement... 17:26:14 Voltage Offset Correction: v_off_ini = 841.997 uV, v_off_fin = 852.305 uV 17:26:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.101 uVs 17:26:14 Integrated Voltage Measurement... 17:26:23 Voltage Offset Correction: v_off_ini = 859.487 uV, v_off_fin = 858.763 uV 17:26:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.540 uVs 17:26:23 Integrated Voltage Measurement... 17:26:32 Voltage Offset Correction: v_off_ini = 855.446 uV, v_off_fin = 849.891 uV 17:26:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.980 uVs 17:26:32 Integrated Voltage Measurement... 17:26:41 Voltage Offset Correction: v_off_ini = 846.915 uV, v_off_fin = 847.584 uV 17:26:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.902 uVs 17:26:41 Integrated Voltage Measurement... 17:26:50 Voltage Offset Correction: v_off_ini = 856.768 uV, v_off_fin = 853.178 uV 17:26:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.057 uVs 17:26:50 Integrated Voltage Measurement... 17:26:59 Voltage Offset Correction: v_off_ini = 846.792 uV, v_off_fin = 843.057 uV 17:26:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.026 uVs 17:27:02 I2Y Average and RMS of Measurements VT = -245.434 +- 12.261 uVs I2Y = -22.580 +- 1.128 uTm^2 17:27:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:27:10 Integrated Voltage Measurement... 17:27:19 Voltage Offset Correction: v_off_ini = 849.750 uV, v_off_fin = 850.560 uV 17:27:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -98.062 uVs 17:27:19 Integrated Voltage Measurement... 17:27:28 Voltage Offset Correction: v_off_ini = 850.016 uV, v_off_fin = 846.432 uV 17:27:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.940 uVs 17:27:28 Integrated Voltage Measurement... 17:27:37 Voltage Offset Correction: v_off_ini = 849.261 uV, v_off_fin = 842.048 uV 17:27:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.609 uVs 17:27:37 Integrated Voltage Measurement... 17:27:46 Voltage Offset Correction: v_off_ini = 859.487 uV, v_off_fin = 835.746 uV 17:27:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.795 uVs 17:27:46 Integrated Voltage Measurement... 17:27:55 Voltage Offset Correction: v_off_ini = 836.400 uV, v_off_fin = 837.932 uV 17:27:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.154 uVs 17:27:55 Integrated Voltage Measurement... 17:28:04 Voltage Offset Correction: v_off_ini = 854.035 uV, v_off_fin = 853.730 uV 17:28:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.188 uVs 17:28:09 I1X Average and RMS of Measurements VT = -102.791 +- 7.503 uVs I1X = 20.560 +- 1.499 uTm 17:28:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:28:15 Integrated Voltage Measurement... 17:28:24 Voltage Offset Correction: v_off_ini = 861.394 uV, v_off_fin = 848.329 uV 17:28:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.323 uVs 17:28:24 Integrated Voltage Measurement... 17:28:33 Voltage Offset Correction: v_off_ini = 866.579 uV, v_off_fin = 869.379 uV 17:28:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.375 uVs 17:28:33 Integrated Voltage Measurement... 17:28:42 Voltage Offset Correction: v_off_ini = 871.624 uV, v_off_fin = 852.352 uV 17:28:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.604 uVs 17:28:42 Integrated Voltage Measurement... 17:28:51 Voltage Offset Correction: v_off_ini = 854.510 uV, v_off_fin = 859.869 uV 17:28:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.144 uVs 17:28:51 Integrated Voltage Measurement... 17:29:00 Voltage Offset Correction: v_off_ini = 869.351 uV, v_off_fin = 874.926 uV 17:29:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.894 uVs 17:29:00 Integrated Voltage Measurement... 17:29:09 Voltage Offset Correction: v_off_ini = 861.548 uV, v_off_fin = 878.140 uV 17:29:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.161 uVs 17:29:14 I1Y Average and RMS of Measurements VT = -192.917 +- 4.767 uVs I1Y = -38.582 +- 0.952 uTm 17:29:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:29:19 Integrated Voltage Measurement... 17:29:28 Voltage Offset Correction: v_off_ini = 844.449 uV, v_off_fin = 850.711 uV 17:29:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.084 uVs 17:29:28 Integrated Voltage Measurement... 17:29:37 Voltage Offset Correction: v_off_ini = 873.897 uV, v_off_fin = 876.755 uV 17:29:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.396 uVs 17:29:37 Integrated Voltage Measurement... 17:29:46 Voltage Offset Correction: v_off_ini = 874.088 uV, v_off_fin = 860.653 uV 17:29:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.891 uVs 17:29:46 Integrated Voltage Measurement... 17:29:55 Voltage Offset Correction: v_off_ini = 870.934 uV, v_off_fin = 870.543 uV 17:29:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.503 uVs 17:29:55 Integrated Voltage Measurement... 17:30:04 Voltage Offset Correction: v_off_ini = 871.104 uV, v_off_fin = 854.264 uV 17:30:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -62.345 uVs 17:30:04 Integrated Voltage Measurement... 17:30:13 Voltage Offset Correction: v_off_ini = 874.248 uV, v_off_fin = 878.397 uV 17:30:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 60.038 uVs 17:30:15 I2X Average and RMS of Measurements VT = -68.710 +- 5.353 uVs I2X = 6.321 +- 0.492 uTm^2 17:30:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:30:20 Integrated Voltage Measurement... 17:30:29 Voltage Offset Correction: v_off_ini = 852.036 uV, v_off_fin = 860.753 uV 17:30:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.894 uVs 17:30:30 Integrated Voltage Measurement... 17:30:38 Voltage Offset Correction: v_off_ini = 857.315 uV, v_off_fin = 855.170 uV 17:30:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.842 uVs 17:30:39 Integrated Voltage Measurement... 17:30:48 Voltage Offset Correction: v_off_ini = 860.077 uV, v_off_fin = 870.372 uV 17:30:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.787 uVs 17:30:48 Integrated Voltage Measurement... 17:30:57 Voltage Offset Correction: v_off_ini = 864.501 uV, v_off_fin = 869.259 uV 17:30:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.572 uVs 17:30:57 Integrated Voltage Measurement... 17:31:06 Voltage Offset Correction: v_off_ini = 870.646 uV, v_off_fin = 871.103 uV 17:31:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.922 uVs 17:31:06 Integrated Voltage Measurement... 17:31:15 Voltage Offset Correction: v_off_ini = 865.526 uV, v_off_fin = 874.030 uV 17:31:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.270 uVs 17:31:17 I2Y Average and RMS of Measurements VT = -237.714 +- 5.227 uVs I2Y = -21.870 +- 0.481 uTm^2 17:31:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:31:25 Integrated Voltage Measurement... 17:31:34 Voltage Offset Correction: v_off_ini = 863.948 uV, v_off_fin = 864.773 uV 17:31:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.105 uVs 17:31:34 Integrated Voltage Measurement... 17:31:43 Voltage Offset Correction: v_off_ini = 868.094 uV, v_off_fin = 856.469 uV 17:31:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.061 uVs 17:31:43 Integrated Voltage Measurement... 17:31:52 Voltage Offset Correction: v_off_ini = 858.998 uV, v_off_fin = 846.956 uV 17:31:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.833 uVs 17:31:52 Integrated Voltage Measurement... 17:32:01 Voltage Offset Correction: v_off_ini = 847.083 uV, v_off_fin = 852.053 uV 17:32:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.955 uVs 17:32:01 Integrated Voltage Measurement... 17:32:10 Voltage Offset Correction: v_off_ini = 857.550 uV, v_off_fin = 850.688 uV 17:32:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.076 uVs 17:32:10 Integrated Voltage Measurement... 17:32:19 Voltage Offset Correction: v_off_ini = 859.678 uV, v_off_fin = 864.672 uV 17:32:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.515 uVs 17:32:24 I1X Average and RMS of Measurements VT = -92.591 +- 5.968 uVs I1X = 18.519 +- 1.194 uTm 17:32:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:32:30 Integrated Voltage Measurement... 17:32:39 Voltage Offset Correction: v_off_ini = 845.164 uV, v_off_fin = 841.269 uV 17:32:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.161 uVs 17:32:39 Integrated Voltage Measurement... 17:32:48 Voltage Offset Correction: v_off_ini = 847.310 uV, v_off_fin = 862.720 uV 17:32:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.263 uVs 17:32:48 Integrated Voltage Measurement... 17:32:57 Voltage Offset Correction: v_off_ini = 851.569 uV, v_off_fin = 844.474 uV 17:32:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.679 uVs 17:32:57 Integrated Voltage Measurement... 17:33:06 Voltage Offset Correction: v_off_ini = 865.434 uV, v_off_fin = 870.547 uV 17:33:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.729 uVs 17:33:06 Integrated Voltage Measurement... 17:33:15 Voltage Offset Correction: v_off_ini = 855.917 uV, v_off_fin = 832.393 uV 17:33:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.722 uVs 17:33:15 Integrated Voltage Measurement... 17:33:24 Voltage Offset Correction: v_off_ini = 859.315 uV, v_off_fin = 849.395 uV 17:33:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.224 uVs 17:33:28 I1Y Average and RMS of Measurements VT = -190.296 +- 3.132 uVs I1Y = -38.057 +- 0.626 uTm 17:33:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:33:34 Integrated Voltage Measurement... 17:33:43 Voltage Offset Correction: v_off_ini = 833.623 uV, v_off_fin = 835.664 uV 17:33:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.721 uVs 17:33:43 Integrated Voltage Measurement... 17:33:52 Voltage Offset Correction: v_off_ini = 837.937 uV, v_off_fin = 866.622 uV 17:33:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.971 uVs 17:33:52 Integrated Voltage Measurement... 17:34:01 Voltage Offset Correction: v_off_ini = 843.089 uV, v_off_fin = 841.105 uV 17:34:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.888 uVs 17:34:01 Integrated Voltage Measurement... 17:34:10 Voltage Offset Correction: v_off_ini = 839.692 uV, v_off_fin = 846.723 uV 17:34:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.930 uVs 17:34:10 Integrated Voltage Measurement... 17:34:19 Voltage Offset Correction: v_off_ini = 834.643 uV, v_off_fin = 844.703 uV 17:34:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.338 uVs 17:34:19 Integrated Voltage Measurement... 17:34:28 Voltage Offset Correction: v_off_ini = 872.395 uV, v_off_fin = 859.193 uV 17:34:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.674 uVs 17:34:30 I2X Average and RMS of Measurements VT = -66.420 +- 8.850 uVs I2X = 6.111 +- 0.814 uTm^2 17:34:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:34:35 Integrated Voltage Measurement... 17:34:44 Voltage Offset Correction: v_off_ini = 845.196 uV, v_off_fin = 855.436 uV 17:34:44 Integrated Voltage Measurement dXYus = 1.0001 mm, dXYds = 0.0000 mm dXY = 1.0001 mm VT = -246.617 uVs 17:34:44 Integrated Voltage Measurement... 17:34:53 Voltage Offset Correction: v_off_ini = 851.960 uV, v_off_fin = 861.646 uV 17:34:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.256 uVs 17:34:53 Integrated Voltage Measurement... 17:35:02 Voltage Offset Correction: v_off_ini = 871.593 uV, v_off_fin = 875.934 uV 17:35:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.525 uVs 17:35:02 Integrated Voltage Measurement... 17:35:11 Voltage Offset Correction: v_off_ini = 867.063 uV, v_off_fin = 872.881 uV 17:35:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.812 uVs 17:35:11 Integrated Voltage Measurement... 17:35:20 Voltage Offset Correction: v_off_ini = 859.450 uV, v_off_fin = 867.625 uV 17:35:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.522 uVs 17:35:21 Integrated Voltage Measurement... 17:35:29 Voltage Offset Correction: v_off_ini = 864.393 uV, v_off_fin = 863.319 uV 17:35:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.079 uVs 17:35:32 I2Y Average and RMS of Measurements VT = -237.635 +- 2.377 uVs I2Y = -21.862 +- 0.218 uTm^2 17:35:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:35:53 Integrated Voltage Measurement... 17:36:02 Voltage Offset Correction: v_off_ini = 861.721 uV, v_off_fin = 861.646 uV 17:36:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -125.205 uVs 17:36:02 Integrated Voltage Measurement... 17:36:11 Voltage Offset Correction: v_off_ini = 868.784 uV, v_off_fin = 861.079 uV 17:36:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.537 uVs 17:36:11 Integrated Voltage Measurement... 17:36:20 Voltage Offset Correction: v_off_ini = 854.851 uV, v_off_fin = 859.182 uV 17:36:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.217 uVs 17:36:20 Integrated Voltage Measurement... 17:36:29 Voltage Offset Correction: v_off_ini = 872.606 uV, v_off_fin = 880.654 uV 17:36:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.717 uVs 17:36:29 Integrated Voltage Measurement... 17:36:38 Voltage Offset Correction: v_off_ini = 873.465 uV, v_off_fin = 862.517 uV 17:36:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.777 uVs 17:36:38 Integrated Voltage Measurement... 17:36:47 Voltage Offset Correction: v_off_ini = 870.758 uV, v_off_fin = 879.229 uV 17:36:47 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.556 uVs 17:36:51 I1X Average and RMS of Measurements VT = -115.502 +- 3.805 uVs I1X = 23.101 +- 0.762 uTm 17:36:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:36:58 Integrated Voltage Measurement... 17:37:07 Voltage Offset Correction: v_off_ini = 862.094 uV, v_off_fin = 862.334 uV 17:37:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.365 uVs 17:37:07 Integrated Voltage Measurement... 17:37:16 Voltage Offset Correction: v_off_ini = 860.382 uV, v_off_fin = 873.915 uV 17:37:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.525 uVs 17:37:16 Integrated Voltage Measurement... 17:37:25 Voltage Offset Correction: v_off_ini = 869.616 uV, v_off_fin = 860.062 uV 17:37:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.911 uVs 17:37:25 Integrated Voltage Measurement... 17:37:34 Voltage Offset Correction: v_off_ini = 867.980 uV, v_off_fin = 874.869 uV 17:37:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.453 uVs 17:37:34 Integrated Voltage Measurement... 17:37:43 Voltage Offset Correction: v_off_ini = 856.764 uV, v_off_fin = 845.790 uV 17:37:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -140.226 uVs 17:37:43 Integrated Voltage Measurement... 17:37:52 Voltage Offset Correction: v_off_ini = 861.598 uV, v_off_fin = 892.241 uV 17:37:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.332 uVs 17:37:56 I1Y Average and RMS of Measurements VT = -156.469 +- 4.966 uVs I1Y = -31.294 +- 0.993 uTm 17:38:01 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:38:04 Integrated Voltage Measurement... 17:38:13 Voltage Offset Correction: v_off_ini = 869.784 uV, v_off_fin = 863.700 uV 17:38:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.137 uVs 17:38:13 Integrated Voltage Measurement... 17:38:22 Voltage Offset Correction: v_off_ini = 852.078 uV, v_off_fin = 870.644 uV 17:38:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.002 uVs 17:38:22 Integrated Voltage Measurement... 17:38:31 Voltage Offset Correction: v_off_ini = 870.398 uV, v_off_fin = 860.440 uV 17:38:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.564 uVs 17:38:31 Integrated Voltage Measurement... 17:38:40 Voltage Offset Correction: v_off_ini = 883.066 uV, v_off_fin = 882.050 uV 17:38:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.204 uVs 17:38:40 Integrated Voltage Measurement... 17:38:49 Voltage Offset Correction: v_off_ini = 875.145 uV, v_off_fin = 871.111 uV 17:38:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.151 uVs 17:38:49 Integrated Voltage Measurement... 17:38:58 Voltage Offset Correction: v_off_ini = 881.634 uV, v_off_fin = 879.351 uV 17:38:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.424 uVs 17:39:00 I2X Average and RMS of Measurements VT = -98.080 +- 1.060 uVs I2X = 9.023 +- 0.098 uTm^2 17:39:05 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:39:08 Integrated Voltage Measurement... 17:39:17 Voltage Offset Correction: v_off_ini = 871.736 uV, v_off_fin = 877.083 uV 17:39:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.681 uVs 17:39:17 Integrated Voltage Measurement... 17:39:26 Voltage Offset Correction: v_off_ini = 884.062 uV, v_off_fin = 881.848 uV 17:39:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.510 uVs 17:39:26 Integrated Voltage Measurement... 17:39:35 Voltage Offset Correction: v_off_ini = 883.602 uV, v_off_fin = 874.377 uV 17:39:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.756 uVs 17:39:35 Integrated Voltage Measurement... 17:39:44 Voltage Offset Correction: v_off_ini = 872.624 uV, v_off_fin = 879.037 uV 17:39:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.860 uVs 17:39:44 Integrated Voltage Measurement... 17:39:53 Voltage Offset Correction: v_off_ini = 882.908 uV, v_off_fin = 884.565 uV 17:39:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.033 uVs 17:39:53 Integrated Voltage Measurement... 17:40:02 Voltage Offset Correction: v_off_ini = 877.997 uV, v_off_fin = 873.881 uV 17:40:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.238 uVs 17:40:05 I2Y Average and RMS of Measurements VT = -199.846 +- 3.239 uVs I2Y = -18.386 +- 0.298 uTm^2 17:40:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:40:13 Integrated Voltage Measurement... 17:40:22 Voltage Offset Correction: v_off_ini = 897.905 uV, v_off_fin = 870.930 uV 17:40:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.848 uVs 17:40:22 Integrated Voltage Measurement... 17:40:31 Voltage Offset Correction: v_off_ini = 869.616 uV, v_off_fin = 878.262 uV 17:40:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.923 uVs 17:40:31 Integrated Voltage Measurement... 17:40:40 Voltage Offset Correction: v_off_ini = 886.090 uV, v_off_fin = 883.315 uV 17:40:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.404 uVs 17:40:40 Integrated Voltage Measurement... 17:40:49 Voltage Offset Correction: v_off_ini = 894.256 uV, v_off_fin = 888.957 uV 17:40:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.349 uVs 17:40:49 Integrated Voltage Measurement... 17:40:58 Voltage Offset Correction: v_off_ini = 871.774 uV, v_off_fin = 875.856 uV 17:40:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.318 uVs 17:40:58 Integrated Voltage Measurement... 17:41:07 Voltage Offset Correction: v_off_ini = 877.394 uV, v_off_fin = 881.701 uV 17:41:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.567 uVs 17:41:12 I1X Average and RMS of Measurements VT = -114.402 +- 4.276 uVs I1X = 22.881 +- 0.855 uTm 17:41:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:41:18 Integrated Voltage Measurement... 17:41:27 Voltage Offset Correction: v_off_ini = 867.221 uV, v_off_fin = 863.991 uV 17:41:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.756 uVs 17:41:27 Integrated Voltage Measurement... 17:41:36 Voltage Offset Correction: v_off_ini = 870.455 uV, v_off_fin = 894.553 uV 17:41:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.416 uVs 17:41:36 Integrated Voltage Measurement... 17:41:45 Voltage Offset Correction: v_off_ini = 879.854 uV, v_off_fin = 883.379 uV 17:41:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.524 uVs 17:41:45 Integrated Voltage Measurement... 17:41:54 Voltage Offset Correction: v_off_ini = 885.330 uV, v_off_fin = 894.162 uV 17:41:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.996 uVs 17:41:54 Integrated Voltage Measurement... 17:42:03 Voltage Offset Correction: v_off_ini = 869.084 uV, v_off_fin = 855.192 uV 17:42:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -164.155 uVs 17:42:03 Integrated Voltage Measurement... 17:42:12 Voltage Offset Correction: v_off_ini = 885.940 uV, v_off_fin = 888.009 uV 17:42:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.888 uVs 17:42:16 I1Y Average and RMS of Measurements VT = -169.789 +- 3.764 uVs I1Y = -33.958 +- 0.752 uTm 17:42:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:42:24 Integrated Voltage Measurement... 17:42:33 Voltage Offset Correction: v_off_ini = 869.196 uV, v_off_fin = 870.020 uV 17:42:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.769 uVs 17:42:33 Integrated Voltage Measurement... 17:42:42 Voltage Offset Correction: v_off_ini = 864.581 uV, v_off_fin = 864.607 uV 17:42:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 82.784 uVs 17:42:42 Integrated Voltage Measurement... 17:42:51 Voltage Offset Correction: v_off_ini = 845.569 uV, v_off_fin = 858.585 uV 17:42:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.225 uVs 17:42:51 Integrated Voltage Measurement... 17:43:00 Voltage Offset Correction: v_off_ini = 852.562 uV, v_off_fin = 869.631 uV 17:43:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.175 uVs 17:43:00 Integrated Voltage Measurement... 17:43:09 Voltage Offset Correction: v_off_ini = 872.543 uV, v_off_fin = 851.338 uV 17:43:09 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.550 uVs 17:43:09 Integrated Voltage Measurement... 17:43:18 Voltage Offset Correction: v_off_ini = 861.421 uV, v_off_fin = 866.831 uV 17:43:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.425 uVs 17:43:20 I2X Average and RMS of Measurements VT = -87.322 +- 9.938 uVs I2X = 8.034 +- 0.915 uTm^2 17:43:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:43:28 Integrated Voltage Measurement... 17:43:37 Voltage Offset Correction: v_off_ini = 851.978 uV, v_off_fin = 865.262 uV 17:43:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.070 uVs 17:43:37 Integrated Voltage Measurement... 17:43:46 Voltage Offset Correction: v_off_ini = 855.015 uV, v_off_fin = 871.060 uV 17:43:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.058 uVs 17:43:46 Integrated Voltage Measurement... 17:43:55 Voltage Offset Correction: v_off_ini = 864.709 uV, v_off_fin = 851.548 uV 17:43:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.340 uVs 17:43:55 Integrated Voltage Measurement... 17:44:04 Voltage Offset Correction: v_off_ini = 863.410 uV, v_off_fin = 849.305 uV 17:44:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.681 uVs 17:44:04 Integrated Voltage Measurement... 17:44:13 Voltage Offset Correction: v_off_ini = 857.843 uV, v_off_fin = 866.870 uV 17:44:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.335 uVs 17:44:13 Integrated Voltage Measurement... 17:44:22 Voltage Offset Correction: v_off_ini = 870.842 uV, v_off_fin = 878.526 uV 17:44:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.973 uVs 17:44:25 I2Y Average and RMS of Measurements VT = -220.243 +- 4.711 uVs I2Y = -20.262 +- 0.433 uTm^2 17:44:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:44:33 Integrated Voltage Measurement... 17:44:42 Voltage Offset Correction: v_off_ini = 872.124 uV, v_off_fin = 864.137 uV 17:44:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.916 uVs 17:44:42 Integrated Voltage Measurement... 17:44:51 Voltage Offset Correction: v_off_ini = 867.232 uV, v_off_fin = 869.645 uV 17:44:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.227 uVs 17:44:51 Integrated Voltage Measurement... 17:45:00 Voltage Offset Correction: v_off_ini = 877.640 uV, v_off_fin = 873.304 uV 17:45:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.993 uVs 17:45:00 Integrated Voltage Measurement... 17:45:09 Voltage Offset Correction: v_off_ini = 872.893 uV, v_off_fin = 883.202 uV 17:45:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.993 uVs 17:45:09 Integrated Voltage Measurement... 17:45:18 Voltage Offset Correction: v_off_ini = 879.980 uV, v_off_fin = 862.517 uV 17:45:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.005 uVs 17:45:18 Integrated Voltage Measurement... 17:45:27 Voltage Offset Correction: v_off_ini = 874.319 uV, v_off_fin = 878.155 uV 17:45:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.399 uVs 17:45:32 I1X Average and RMS of Measurements VT = -110.922 +- 0.935 uVs I1X = 22.185 +- 0.187 uTm 17:45:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:45:38 Integrated Voltage Measurement... 17:45:47 Voltage Offset Correction: v_off_ini = 870.488 uV, v_off_fin = 874.341 uV 17:45:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.412 uVs 17:45:47 Integrated Voltage Measurement... 17:45:56 Voltage Offset Correction: v_off_ini = 873.878 uV, v_off_fin = 873.602 uV 17:45:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.247 uVs 17:45:56 Integrated Voltage Measurement... 17:46:05 Voltage Offset Correction: v_off_ini = 879.499 uV, v_off_fin = 870.410 uV 17:46:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.192 uVs 17:46:05 Integrated Voltage Measurement... 17:46:14 Voltage Offset Correction: v_off_ini = 873.172 uV, v_off_fin = 892.547 uV 17:46:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.816 uVs 17:46:14 Integrated Voltage Measurement... 17:46:23 Voltage Offset Correction: v_off_ini = 881.819 uV, v_off_fin = 872.598 uV 17:46:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.422 uVs 17:46:23 Integrated Voltage Measurement... 17:46:32 Voltage Offset Correction: v_off_ini = 894.388 uV, v_off_fin = 907.615 uV 17:46:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.314 uVs 17:46:36 I1Y Average and RMS of Measurements VT = -179.567 +- 2.773 uVs I1Y = -35.914 +- 0.554 uTm 17:46:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:46:44 Integrated Voltage Measurement... 17:46:53 Voltage Offset Correction: v_off_ini = 887.585 uV, v_off_fin = 892.114 uV 17:46:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.803 uVs 17:46:53 Integrated Voltage Measurement... 17:47:02 Voltage Offset Correction: v_off_ini = 885.849 uV, v_off_fin = 898.820 uV 17:47:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.830 uVs 17:47:02 Integrated Voltage Measurement... 17:47:11 Voltage Offset Correction: v_off_ini = 895.304 uV, v_off_fin = 885.894 uV 17:47:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.766 uVs 17:47:11 Integrated Voltage Measurement... 17:47:20 Voltage Offset Correction: v_off_ini = 880.426 uV, v_off_fin = 885.944 uV 17:47:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.170 uVs 17:47:20 Integrated Voltage Measurement... 17:47:29 Voltage Offset Correction: v_off_ini = 892.515 uV, v_off_fin = 871.851 uV 17:47:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -93.136 uVs 17:47:29 Integrated Voltage Measurement... 17:47:38 Voltage Offset Correction: v_off_ini = 880.289 uV, v_off_fin = 897.322 uV 17:47:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.785 uVs 17:47:41 I2X Average and RMS of Measurements VT = -85.581 +- 6.420 uVs I2X = 7.874 +- 0.591 uTm^2 17:47:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:47:48 Integrated Voltage Measurement... 17:47:57 Voltage Offset Correction: v_off_ini = 895.204 uV, v_off_fin = 882.466 uV 17:47:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.439 uVs 17:47:57 Integrated Voltage Measurement... 17:48:06 Voltage Offset Correction: v_off_ini = 897.364 uV, v_off_fin = 901.666 uV 17:48:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.542 uVs 17:48:06 Integrated Voltage Measurement... 17:48:15 Voltage Offset Correction: v_off_ini = 898.602 uV, v_off_fin = 886.715 uV 17:48:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.683 uVs 17:48:15 Integrated Voltage Measurement... 17:48:24 Voltage Offset Correction: v_off_ini = 885.519 uV, v_off_fin = 896.248 uV 17:48:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.028 uVs 17:48:24 Integrated Voltage Measurement... 17:48:33 Voltage Offset Correction: v_off_ini = 898.557 uV, v_off_fin = 894.004 uV 17:48:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.324 uVs 17:48:33 Integrated Voltage Measurement... 17:48:42 Voltage Offset Correction: v_off_ini = 893.395 uV, v_off_fin = 904.915 uV 17:48:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.016 uVs 17:48:45 I2Y Average and RMS of Measurements VT = -221.505 +- 6.010 uVs I2Y = -20.378 +- 0.553 uTm^2 17:48:50 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:48:54 Integrated Voltage Measurement... 17:49:03 Voltage Offset Correction: v_off_ini = 896.644 uV, v_off_fin = 902.869 uV 17:49:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -129.282 uVs 17:49:03 Integrated Voltage Measurement... 17:49:12 Voltage Offset Correction: v_off_ini = 901.266 uV, v_off_fin = 905.855 uV 17:49:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.438 uVs 17:49:12 Integrated Voltage Measurement... 17:49:21 Voltage Offset Correction: v_off_ini = 890.866 uV, v_off_fin = 893.475 uV 17:49:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.783 uVs 17:49:21 Integrated Voltage Measurement... 17:49:30 Voltage Offset Correction: v_off_ini = 891.682 uV, v_off_fin = 903.890 uV 17:49:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.146 uVs 17:49:30 Integrated Voltage Measurement... 17:49:39 Voltage Offset Correction: v_off_ini = 897.468 uV, v_off_fin = 895.171 uV 17:49:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.008 uVs 17:49:39 Integrated Voltage Measurement... 17:49:48 Voltage Offset Correction: v_off_ini = 900.583 uV, v_off_fin = 908.451 uV 17:49:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.758 uVs 17:49:52 I1X Average and RMS of Measurements VT = -113.069 +- 8.299 uVs I1X = 22.615 +- 1.661 uTm 17:49:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:49:59 Integrated Voltage Measurement... 17:50:08 Voltage Offset Correction: v_off_ini = 893.750 uV, v_off_fin = 896.766 uV 17:50:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -197.372 uVs 17:50:08 Integrated Voltage Measurement... 17:50:17 Voltage Offset Correction: v_off_ini = 893.687 uV, v_off_fin = 899.725 uV 17:50:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.538 uVs 17:50:17 Integrated Voltage Measurement... 17:50:26 Voltage Offset Correction: v_off_ini = 889.714 uV, v_off_fin = 877.328 uV 17:50:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.907 uVs 17:50:26 Integrated Voltage Measurement... 17:50:35 Voltage Offset Correction: v_off_ini = 892.788 uV, v_off_fin = 901.805 uV 17:50:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.073 uVs 17:50:35 Integrated Voltage Measurement... 17:50:44 Voltage Offset Correction: v_off_ini = 900.015 uV, v_off_fin = 890.146 uV 17:50:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.648 uVs 17:50:44 Integrated Voltage Measurement... 17:50:53 Voltage Offset Correction: v_off_ini = 889.647 uV, v_off_fin = 893.060 uV 17:50:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.879 uVs 17:50:57 I1Y Average and RMS of Measurements VT = -198.736 +- 1.599 uVs I1Y = -39.748 +- 0.319 uTm 17:51:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:51:05 Integrated Voltage Measurement... 17:51:14 Voltage Offset Correction: v_off_ini = 887.953 uV, v_off_fin = 888.910 uV 17:51:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.975 uVs 17:51:14 Integrated Voltage Measurement... 17:51:23 Voltage Offset Correction: v_off_ini = 895.942 uV, v_off_fin = 897.533 uV 17:51:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.173 uVs 17:51:23 Integrated Voltage Measurement... 17:51:32 Voltage Offset Correction: v_off_ini = 901.389 uV, v_off_fin = 874.434 uV 17:51:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.554 uVs 17:51:32 Integrated Voltage Measurement... 17:51:41 Voltage Offset Correction: v_off_ini = 885.987 uV, v_off_fin = 903.585 uV 17:51:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.900 uVs 17:51:41 Integrated Voltage Measurement... 17:51:50 Voltage Offset Correction: v_off_ini = 883.105 uV, v_off_fin = 876.770 uV 17:51:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.770 uVs 17:51:50 Integrated Voltage Measurement... 17:51:59 Voltage Offset Correction: v_off_ini = 884.848 uV, v_off_fin = 898.317 uV 17:51:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.602 uVs 17:52:02 I2X Average and RMS of Measurements VT = -82.662 +- 3.495 uVs I2X = 7.605 +- 0.322 uTm^2 17:52:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:52:09 Integrated Voltage Measurement... 17:52:18 Voltage Offset Correction: v_off_ini = 872.296 uV, v_off_fin = 882.879 uV 17:52:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.900 uVs 17:52:18 Integrated Voltage Measurement... 17:52:27 Voltage Offset Correction: v_off_ini = 877.990 uV, v_off_fin = 875.366 uV 17:52:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.152 uVs 17:52:27 Integrated Voltage Measurement... 17:52:36 Voltage Offset Correction: v_off_ini = 871.986 uV, v_off_fin = 874.588 uV 17:52:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.028 uVs 17:52:36 Integrated Voltage Measurement... 17:52:45 Voltage Offset Correction: v_off_ini = 893.199 uV, v_off_fin = 886.602 uV 17:52:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.660 uVs 17:52:45 Integrated Voltage Measurement... 17:52:54 Voltage Offset Correction: v_off_ini = 882.969 uV, v_off_fin = 881.142 uV 17:52:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.285 uVs 17:52:55 Integrated Voltage Measurement... 17:53:03 Voltage Offset Correction: v_off_ini = 884.227 uV, v_off_fin = 895.262 uV 17:53:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.658 uVs 17:53:06 I2Y Average and RMS of Measurements VT = -239.114 +- 9.777 uVs I2Y = -21.998 +- 0.899 uTm^2 17:53:11 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:53:15 Integrated Voltage Measurement... 17:53:24 Voltage Offset Correction: v_off_ini = 902.558 uV, v_off_fin = 885.818 uV 17:53:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -130.659 uVs 17:53:24 Integrated Voltage Measurement... 17:53:33 Voltage Offset Correction: v_off_ini = 899.797 uV, v_off_fin = 887.168 uV 17:53:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.180 uVs 17:53:33 Integrated Voltage Measurement... 17:53:42 Voltage Offset Correction: v_off_ini = 892.821 uV, v_off_fin = 886.179 uV 17:53:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.560 uVs 17:53:42 Integrated Voltage Measurement... 17:53:51 Voltage Offset Correction: v_off_ini = 896.955 uV, v_off_fin = 893.902 uV 17:53:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.932 uVs 17:53:51 Integrated Voltage Measurement... 17:54:00 Voltage Offset Correction: v_off_ini = 896.404 uV, v_off_fin = 901.324 uV 17:54:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.206 uVs 17:54:00 Integrated Voltage Measurement... 17:54:09 Voltage Offset Correction: v_off_ini = 876.183 uV, v_off_fin = 889.290 uV 17:54:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.638 uVs 17:54:13 I1X Average and RMS of Measurements VT = -103.696 +- 4.974 uVs I1X = 20.741 +- 0.995 uTm 17:54:16 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:54:20 Integrated Voltage Measurement... 17:54:29 Voltage Offset Correction: v_off_ini = 903.379 uV, v_off_fin = 890.669 uV 17:54:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -209.929 uVs 17:54:29 Integrated Voltage Measurement... 17:54:38 Voltage Offset Correction: v_off_ini = 903.611 uV, v_off_fin = 913.043 uV 17:54:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.974 uVs 17:54:38 Integrated Voltage Measurement... 17:54:47 Voltage Offset Correction: v_off_ini = 896.283 uV, v_off_fin = 894.161 uV 17:54:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.430 uVs 17:54:47 Integrated Voltage Measurement... 17:54:56 Voltage Offset Correction: v_off_ini = 918.172 uV, v_off_fin = 921.697 uV 17:54:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.455 uVs 17:54:56 Integrated Voltage Measurement... 17:55:05 Voltage Offset Correction: v_off_ini = 904.979 uV, v_off_fin = 891.913 uV 17:55:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.882 uVs 17:55:05 Integrated Voltage Measurement... 17:55:14 Voltage Offset Correction: v_off_ini = 908.920 uV, v_off_fin = 912.190 uV 17:55:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.076 uVs 17:55:18 I1Y Average and RMS of Measurements VT = -196.291 +- 4.927 uVs I1Y = -39.259 +- 0.986 uTm 17:55:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:55:26 Integrated Voltage Measurement... 17:55:35 Voltage Offset Correction: v_off_ini = 877.104 uV, v_off_fin = 891.687 uV 17:55:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -82.834 uVs 17:55:35 Integrated Voltage Measurement... 17:55:44 Voltage Offset Correction: v_off_ini = 905.362 uV, v_off_fin = 908.985 uV 17:55:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.260 uVs 17:55:44 Integrated Voltage Measurement... 17:55:53 Voltage Offset Correction: v_off_ini = 895.022 uV, v_off_fin = 895.785 uV 17:55:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.178 uVs 17:55:53 Integrated Voltage Measurement... 17:56:02 Voltage Offset Correction: v_off_ini = 911.970 uV, v_off_fin = 928.816 uV 17:56:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 66.890 uVs 17:56:02 Integrated Voltage Measurement... 17:56:11 Voltage Offset Correction: v_off_ini = 922.536 uV, v_off_fin = 906.978 uV 17:56:11 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -60.127 uVs 17:56:11 Integrated Voltage Measurement... 17:56:20 Voltage Offset Correction: v_off_ini = 911.379 uV, v_off_fin = 918.614 uV 17:56:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.221 uVs 17:56:23 I2X Average and RMS of Measurements VT = -71.585 +- 5.205 uVs I2X = 6.586 +- 0.479 uTm^2 17:56:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:56:30 Integrated Voltage Measurement... 17:56:39 Voltage Offset Correction: v_off_ini = 899.366 uV, v_off_fin = 909.192 uV 17:56:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -246.345 uVs 17:56:39 Integrated Voltage Measurement... 17:56:48 Voltage Offset Correction: v_off_ini = 918.680 uV, v_off_fin = 907.469 uV 17:56:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.446 uVs 17:56:48 Integrated Voltage Measurement... 17:56:57 Voltage Offset Correction: v_off_ini = 917.241 uV, v_off_fin = 907.662 uV 17:56:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.093 uVs 17:56:57 Integrated Voltage Measurement... 17:57:06 Voltage Offset Correction: v_off_ini = 908.975 uV, v_off_fin = 915.533 uV 17:57:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.658 uVs 17:57:07 Integrated Voltage Measurement... 17:57:16 Voltage Offset Correction: v_off_ini = 917.976 uV, v_off_fin = 921.898 uV 17:57:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.554 uVs 17:57:16 Integrated Voltage Measurement... 17:57:25 Voltage Offset Correction: v_off_ini = 928.792 uV, v_off_fin = 911.330 uV 17:57:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.067 uVs 17:57:27 I2Y Average and RMS of Measurements VT = -237.860 +- 2.124 uVs I2Y = -21.884 +- 0.195 uTm^2 17:57:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:57:39 Integrated Voltage Measurement... 17:57:48 Voltage Offset Correction: v_off_ini = 909.493 uV, v_off_fin = 884.400 uV 17:57:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.153 uVs 17:57:48 Integrated Voltage Measurement... 17:57:57 Voltage Offset Correction: v_off_ini = 878.487 uV, v_off_fin = 895.963 uV 17:57:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.227 uVs 17:57:57 Integrated Voltage Measurement... 17:58:06 Voltage Offset Correction: v_off_ini = 921.740 uV, v_off_fin = 900.715 uV 17:58:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.416 uVs 17:58:06 Integrated Voltage Measurement... 17:58:15 Voltage Offset Correction: v_off_ini = 907.106 uV, v_off_fin = 910.034 uV 17:58:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.550 uVs 17:58:15 Integrated Voltage Measurement... 17:58:24 Voltage Offset Correction: v_off_ini = 916.607 uV, v_off_fin = 903.515 uV 17:58:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -124.166 uVs 17:58:24 Integrated Voltage Measurement... 17:58:33 Voltage Offset Correction: v_off_ini = 898.852 uV, v_off_fin = 906.756 uV 17:58:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 116.912 uVs 17:58:37 I1X Average and RMS of Measurements VT = -125.571 +- 3.592 uVs I1X = 25.117 +- 0.715 uTm 17:58:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:58:44 Integrated Voltage Measurement... 17:58:53 Voltage Offset Correction: v_off_ini = 889.415 uV, v_off_fin = 881.533 uV 17:58:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.757 uVs 17:58:53 Integrated Voltage Measurement... 17:59:02 Voltage Offset Correction: v_off_ini = 898.522 uV, v_off_fin = 903.745 uV 17:59:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = 186.916 uVs 17:59:02 Integrated Voltage Measurement... 17:59:11 Voltage Offset Correction: v_off_ini = 897.001 uV, v_off_fin = 889.833 uV 17:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.423 uVs 17:59:11 Integrated Voltage Measurement... 17:59:20 Voltage Offset Correction: v_off_ini = 921.483 uV, v_off_fin = 894.351 uV 17:59:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 175.275 uVs 17:59:20 Integrated Voltage Measurement... 17:59:29 Voltage Offset Correction: v_off_ini = 880.123 uV, v_off_fin = 879.251 uV 17:59:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.185 uVs 17:59:29 Integrated Voltage Measurement... 17:59:38 Voltage Offset Correction: v_off_ini = 889.634 uV, v_off_fin = 901.905 uV 17:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.947 uVs 17:59:42 I1Y Average and RMS of Measurements VT = -188.251 +- 7.449 uVs I1Y = -37.652 +- 1.489 uTm 17:59:45 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:59:48 Integrated Voltage Measurement... 17:59:57 Voltage Offset Correction: v_off_ini = 890.072 uV, v_off_fin = 889.000 uV 17:59:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -72.758 uVs 17:59:57 Integrated Voltage Measurement... 18:00:06 Voltage Offset Correction: v_off_ini = 899.573 uV, v_off_fin = 897.140 uV 18:00:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 97.212 uVs 18:00:06 Integrated Voltage Measurement... 18:00:15 Voltage Offset Correction: v_off_ini = 890.338 uV, v_off_fin = 877.717 uV 18:00:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.381 uVs 18:00:15 Integrated Voltage Measurement... 18:00:24 Voltage Offset Correction: v_off_ini = 893.293 uV, v_off_fin = 895.279 uV 18:00:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 92.186 uVs 18:00:24 Integrated Voltage Measurement... 18:00:33 Voltage Offset Correction: v_off_ini = 889.155 uV, v_off_fin = 877.974 uV 18:00:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.005 uVs 18:00:33 Integrated Voltage Measurement... 18:00:42 Voltage Offset Correction: v_off_ini = 873.001 uV, v_off_fin = 871.799 uV 18:00:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.735 uVs 18:00:44 I2X Average and RMS of Measurements VT = -89.046 +- 5.534 uVs I2X = 8.193 +- 0.509 uTm^2 18:00:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:00:49 Integrated Voltage Measurement... 18:00:58 Voltage Offset Correction: v_off_ini = 878.132 uV, v_off_fin = 875.348 uV 18:00:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.754 uVs 18:00:58 Integrated Voltage Measurement... 18:01:07 Voltage Offset Correction: v_off_ini = 873.592 uV, v_off_fin = 870.660 uV 18:01:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.293 uVs 18:01:07 Integrated Voltage Measurement... 18:01:16 Voltage Offset Correction: v_off_ini = 867.601 uV, v_off_fin = 868.508 uV 18:01:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.026 uVs 18:01:16 Integrated Voltage Measurement... 18:01:25 Voltage Offset Correction: v_off_ini = 878.160 uV, v_off_fin = 882.689 uV 18:01:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.126 uVs 18:01:26 Integrated Voltage Measurement... 18:01:35 Voltage Offset Correction: v_off_ini = 883.585 uV, v_off_fin = 874.201 uV 18:01:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -221.169 uVs 18:01:35 Integrated Voltage Measurement... 18:01:44 Voltage Offset Correction: v_off_ini = 872.407 uV, v_off_fin = 868.857 uV 18:01:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.944 uVs 18:01:46 I2Y Average and RMS of Measurements VT = -220.219 +- 5.152 uVs I2Y = -20.260 +- 0.474 uTm^2 18:01:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:01:54 Integrated Voltage Measurement... 18:02:03 Voltage Offset Correction: v_off_ini = 877.246 uV, v_off_fin = 868.242 uV 18:02:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.202 uVs 18:02:03 Integrated Voltage Measurement... 18:02:12 Voltage Offset Correction: v_off_ini = 877.541 uV, v_off_fin = 875.820 uV 18:02:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.042 uVs 18:02:12 Integrated Voltage Measurement... 18:02:21 Voltage Offset Correction: v_off_ini = 872.104 uV, v_off_fin = 874.227 uV 18:02:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.031 uVs 18:02:21 Integrated Voltage Measurement... 18:02:30 Voltage Offset Correction: v_off_ini = 894.450 uV, v_off_fin = 894.857 uV 18:02:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 96.353 uVs 18:02:30 Integrated Voltage Measurement... 18:02:39 Voltage Offset Correction: v_off_ini = 886.426 uV, v_off_fin = 892.963 uV 18:02:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.519 uVs 18:02:39 Integrated Voltage Measurement... 18:02:48 Voltage Offset Correction: v_off_ini = 879.408 uV, v_off_fin = 890.790 uV 18:02:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.225 uVs 18:02:53 I1X Average and RMS of Measurements VT = -110.395 +- 4.828 uVs I1X = 22.080 +- 0.966 uTm 18:02:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:02:59 Integrated Voltage Measurement... 18:03:08 Voltage Offset Correction: v_off_ini = 879.680 uV, v_off_fin = 877.016 uV 18:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.732 uVs 18:03:08 Integrated Voltage Measurement... 18:03:17 Voltage Offset Correction: v_off_ini = 885.786 uV, v_off_fin = 896.392 uV 18:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.470 uVs 18:03:17 Integrated Voltage Measurement... 18:03:26 Voltage Offset Correction: v_off_ini = 875.503 uV, v_off_fin = 875.059 uV 18:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.687 uVs 18:03:26 Integrated Voltage Measurement... 18:03:35 Voltage Offset Correction: v_off_ini = 893.295 uV, v_off_fin = 897.052 uV 18:03:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.396 uVs 18:03:36 Integrated Voltage Measurement... 18:03:44 Voltage Offset Correction: v_off_ini = 888.592 uV, v_off_fin = 871.069 uV 18:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.567 uVs 18:03:45 Integrated Voltage Measurement... 18:03:53 Voltage Offset Correction: v_off_ini = 878.567 uV, v_off_fin = 886.760 uV 18:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.369 uVs 18:03:58 I1Y Average and RMS of Measurements VT = -178.204 +- 2.276 uVs I1Y = -35.641 +- 0.455 uTm 18:04:00 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:04:03 Integrated Voltage Measurement... 18:04:12 Voltage Offset Correction: v_off_ini = 866.596 uV, v_off_fin = 860.824 uV 18:04:12 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.479 uVs 18:04:12 Integrated Voltage Measurement... 18:04:21 Voltage Offset Correction: v_off_ini = 883.890 uV, v_off_fin = 893.033 uV 18:04:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.080 uVs 18:04:21 Integrated Voltage Measurement... 18:04:30 Voltage Offset Correction: v_off_ini = 876.546 uV, v_off_fin = 867.170 uV 18:04:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.696 uVs 18:04:30 Integrated Voltage Measurement... 18:04:39 Voltage Offset Correction: v_off_ini = 871.636 uV, v_off_fin = 883.632 uV 18:04:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.579 uVs 18:04:39 Integrated Voltage Measurement... 18:04:48 Voltage Offset Correction: v_off_ini = 883.152 uV, v_off_fin = 874.244 uV 18:04:48 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -77.187 uVs 18:04:48 Integrated Voltage Measurement... 18:04:57 Voltage Offset Correction: v_off_ini = 874.536 uV, v_off_fin = 878.788 uV 18:04:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.433 uVs 18:04:59 I2X Average and RMS of Measurements VT = -84.409 +- 1.761 uVs I2X = 7.766 +- 0.162 uTm^2 18:05:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:05:05 Integrated Voltage Measurement... 18:05:14 Voltage Offset Correction: v_off_ini = 889.312 uV, v_off_fin = 890.019 uV 18:05:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.228 uVs 18:05:14 Integrated Voltage Measurement... 18:05:23 Voltage Offset Correction: v_off_ini = 870.719 uV, v_off_fin = 870.747 uV 18:05:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.868 uVs 18:05:23 Integrated Voltage Measurement... 18:05:32 Voltage Offset Correction: v_off_ini = 864.946 uV, v_off_fin = 875.512 uV 18:05:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.667 uVs 18:05:32 Integrated Voltage Measurement... 18:05:41 Voltage Offset Correction: v_off_ini = 870.455 uV, v_off_fin = 891.591 uV 18:05:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.038 uVs 18:05:41 Integrated Voltage Measurement... 18:05:50 Voltage Offset Correction: v_off_ini = 875.703 uV, v_off_fin = 880.912 uV 18:05:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.280 uVs 18:05:50 Integrated Voltage Measurement... 18:05:59 Voltage Offset Correction: v_off_ini = 872.864 uV, v_off_fin = 874.250 uV 18:05:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.223 uVs 18:06:01 I2Y Average and RMS of Measurements VT = -228.217 +- 5.816 uVs I2Y = -20.996 +- 0.535 uTm^2 18:06:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:06:09 Integrated Voltage Measurement... 18:06:18 Voltage Offset Correction: v_off_ini = 866.696 uV, v_off_fin = 859.976 uV 18:06:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -106.835 uVs 18:06:19 Integrated Voltage Measurement... 18:06:28 Voltage Offset Correction: v_off_ini = 868.651 uV, v_off_fin = 864.231 uV 18:06:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.252 uVs 18:06:28 Integrated Voltage Measurement... 18:06:37 Voltage Offset Correction: v_off_ini = 870.969 uV, v_off_fin = 871.812 uV 18:06:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.211 uVs 18:06:37 Integrated Voltage Measurement... 18:06:46 Voltage Offset Correction: v_off_ini = 875.910 uV, v_off_fin = 886.090 uV 18:06:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.553 uVs 18:06:46 Integrated Voltage Measurement... 18:06:55 Voltage Offset Correction: v_off_ini = 884.783 uV, v_off_fin = 884.471 uV 18:06:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.753 uVs 18:06:55 Integrated Voltage Measurement... 18:07:04 Voltage Offset Correction: v_off_ini = 885.761 uV, v_off_fin = 878.105 uV 18:07:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.897 uVs 18:07:08 I1X Average and RMS of Measurements VT = -103.250 +- 5.262 uVs I1X = 20.651 +- 1.054 uTm 18:07:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:07:15 Integrated Voltage Measurement... 18:07:24 Voltage Offset Correction: v_off_ini = 874.546 uV, v_off_fin = 869.169 uV 18:07:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.624 uVs 18:07:24 Integrated Voltage Measurement... 18:07:33 Voltage Offset Correction: v_off_ini = 869.424 uV, v_off_fin = 869.267 uV 18:07:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.426 uVs 18:07:33 Integrated Voltage Measurement... 18:07:42 Voltage Offset Correction: v_off_ini = 851.378 uV, v_off_fin = 860.303 uV 18:07:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.434 uVs 18:07:42 Integrated Voltage Measurement... 18:07:51 Voltage Offset Correction: v_off_ini = 871.456 uV, v_off_fin = 878.938 uV 18:07:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.773 uVs 18:07:51 Integrated Voltage Measurement... 18:08:00 Voltage Offset Correction: v_off_ini = 880.460 uV, v_off_fin = 864.273 uV 18:08:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.922 uVs 18:08:00 Integrated Voltage Measurement... 18:08:09 Voltage Offset Correction: v_off_ini = 882.026 uV, v_off_fin = 892.595 uV 18:08:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.003 uVs 18:08:13 I1Y Average and RMS of Measurements VT = -181.530 +- 4.213 uVs I1Y = -36.307 +- 0.842 uTm 18:08:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:08:18 Integrated Voltage Measurement... 18:08:27 Voltage Offset Correction: v_off_ini = 855.699 uV, v_off_fin = 857.919 uV 18:08:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.200 uVs 18:08:27 Integrated Voltage Measurement... 18:08:36 Voltage Offset Correction: v_off_ini = 875.869 uV, v_off_fin = 889.010 uV 18:08:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.897 uVs 18:08:36 Integrated Voltage Measurement... 18:08:45 Voltage Offset Correction: v_off_ini = 885.354 uV, v_off_fin = 867.096 uV 18:08:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.385 uVs 18:08:45 Integrated Voltage Measurement... 18:08:54 Voltage Offset Correction: v_off_ini = 862.690 uV, v_off_fin = 878.068 uV 18:08:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.163 uVs 18:08:54 Integrated Voltage Measurement... 18:09:03 Voltage Offset Correction: v_off_ini = 867.894 uV, v_off_fin = 853.011 uV 18:09:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.880 uVs 18:09:03 Integrated Voltage Measurement... 18:09:12 Voltage Offset Correction: v_off_ini = 875.945 uV, v_off_fin = 883.192 uV 18:09:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.431 uVs 18:09:15 I2X Average and RMS of Measurements VT = -72.993 +- 11.533 uVs I2X = 6.715 +- 1.061 uTm^2 18:09:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:09:20 Integrated Voltage Measurement... 18:09:29 Voltage Offset Correction: v_off_ini = 866.397 uV, v_off_fin = 871.722 uV 18:09:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.389 uVs 18:09:29 Integrated Voltage Measurement... 18:09:38 Voltage Offset Correction: v_off_ini = 865.869 uV, v_off_fin = 865.628 uV 18:09:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.786 uVs 18:09:38 Integrated Voltage Measurement... 18:09:47 Voltage Offset Correction: v_off_ini = 867.438 uV, v_off_fin = 864.917 uV 18:09:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.861 uVs 18:09:47 Integrated Voltage Measurement... 18:09:56 Voltage Offset Correction: v_off_ini = 862.181 uV, v_off_fin = 870.444 uV 18:09:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.221 uVs 18:09:56 Integrated Voltage Measurement... 18:10:05 Voltage Offset Correction: v_off_ini = 871.936 uV, v_off_fin = 871.620 uV 18:10:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.531 uVs 18:10:05 Integrated Voltage Measurement... 18:10:14 Voltage Offset Correction: v_off_ini = 879.957 uV, v_off_fin = 883.351 uV 18:10:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.260 uVs 18:10:16 I2Y Average and RMS of Measurements VT = -227.175 +- 3.756 uVs I2Y = -20.900 +- 0.346 uTm^2 18:10:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:10:25 Integrated Voltage Measurement... 18:10:34 Voltage Offset Correction: v_off_ini = 882.297 uV, v_off_fin = 867.114 uV 18:10:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.147 uVs 18:10:34 Integrated Voltage Measurement... 18:10:43 Voltage Offset Correction: v_off_ini = 865.175 uV, v_off_fin = 868.927 uV 18:10:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.463 uVs 18:10:43 Integrated Voltage Measurement... 18:10:52 Voltage Offset Correction: v_off_ini = 879.430 uV, v_off_fin = 864.968 uV 18:10:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.732 uVs 18:10:52 Integrated Voltage Measurement... 18:11:01 Voltage Offset Correction: v_off_ini = 871.332 uV, v_off_fin = 860.137 uV 18:11:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.091 uVs 18:11:01 Integrated Voltage Measurement... 18:11:10 Voltage Offset Correction: v_off_ini = 868.312 uV, v_off_fin = 867.564 uV 18:11:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.502 uVs 18:11:10 Integrated Voltage Measurement... 18:11:19 Voltage Offset Correction: v_off_ini = 879.630 uV, v_off_fin = 858.710 uV 18:11:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.478 uVs 18:11:23 I1X Average and RMS of Measurements VT = -101.235 +- 5.649 uVs I1X = 20.247 +- 1.130 uTm 18:11:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:11:30 Integrated Voltage Measurement... 18:11:39 Voltage Offset Correction: v_off_ini = 879.470 uV, v_off_fin = 852.770 uV 18:11:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -174.600 uVs 18:11:39 Integrated Voltage Measurement... 18:11:48 Voltage Offset Correction: v_off_ini = 862.834 uV, v_off_fin = 863.218 uV 18:11:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.366 uVs 18:11:48 Integrated Voltage Measurement... 18:11:57 Voltage Offset Correction: v_off_ini = 862.240 uV, v_off_fin = 858.784 uV 18:11:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.194 uVs 18:11:57 Integrated Voltage Measurement... 18:12:06 Voltage Offset Correction: v_off_ini = 857.790 uV, v_off_fin = 873.593 uV 18:12:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.433 uVs 18:12:06 Integrated Voltage Measurement... 18:12:15 Voltage Offset Correction: v_off_ini = 857.770 uV, v_off_fin = 845.924 uV 18:12:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -163.720 uVs 18:12:15 Integrated Voltage Measurement... 18:12:24 Voltage Offset Correction: v_off_ini = 859.125 uV, v_off_fin = 870.740 uV 18:12:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.188 uVs 18:12:28 I1Y Average and RMS of Measurements VT = -178.250 +- 4.058 uVs I1Y = -35.647 +- 0.812 uTm 18:12:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:12:33 Integrated Voltage Measurement... 18:12:42 Voltage Offset Correction: v_off_ini = 854.857 uV, v_off_fin = 846.073 uV 18:12:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.538 uVs 18:12:42 Integrated Voltage Measurement... 18:12:51 Voltage Offset Correction: v_off_ini = 861.217 uV, v_off_fin = 868.409 uV 18:12:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.362 uVs 18:12:51 Integrated Voltage Measurement... 18:13:00 Voltage Offset Correction: v_off_ini = 871.064 uV, v_off_fin = 861.304 uV 18:13:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -80.110 uVs 18:13:00 Integrated Voltage Measurement... 18:13:09 Voltage Offset Correction: v_off_ini = 860.686 uV, v_off_fin = 868.392 uV 18:13:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.971 uVs 18:13:09 Integrated Voltage Measurement... 18:13:18 Voltage Offset Correction: v_off_ini = 872.350 uV, v_off_fin = 866.270 uV 18:13:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.685 uVs 18:13:18 Integrated Voltage Measurement... 18:13:27 Voltage Offset Correction: v_off_ini = 858.046 uV, v_off_fin = 865.881 uV 18:13:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.075 uVs 18:13:30 I2X Average and RMS of Measurements VT = -77.457 +- 8.895 uVs I2X = 7.126 +- 0.818 uTm^2 18:13:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:13:35 Integrated Voltage Measurement... 18:13:44 Voltage Offset Correction: v_off_ini = 860.822 uV, v_off_fin = 852.644 uV 18:13:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.449 uVs 18:13:44 Integrated Voltage Measurement... 18:13:53 Voltage Offset Correction: v_off_ini = 869.303 uV, v_off_fin = 870.432 uV 18:13:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.573 uVs 18:13:53 Integrated Voltage Measurement... 18:14:02 Voltage Offset Correction: v_off_ini = 853.826 uV, v_off_fin = 861.648 uV 18:14:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.878 uVs 18:14:02 Integrated Voltage Measurement... 18:14:11 Voltage Offset Correction: v_off_ini = 881.041 uV, v_off_fin = 856.763 uV 18:14:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.375 uVs 18:14:11 Integrated Voltage Measurement... 18:14:20 Voltage Offset Correction: v_off_ini = 855.040 uV, v_off_fin = 844.394 uV 18:14:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -222.914 uVs 18:14:20 Integrated Voltage Measurement... 18:14:29 Voltage Offset Correction: v_off_ini = 847.376 uV, v_off_fin = 839.203 uV 18:14:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.260 uVs 18:14:32 I2Y Average and RMS of Measurements VT = -220.742 +- 2.393 uVs I2Y = -20.309 +- 0.221 uTm^2 18:14:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:14:40 Integrated Voltage Measurement... 18:14:49 Voltage Offset Correction: v_off_ini = 851.058 uV, v_off_fin = 832.291 uV 18:14:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -100.607 uVs 18:14:49 Integrated Voltage Measurement... 18:14:58 Voltage Offset Correction: v_off_ini = 847.651 uV, v_off_fin = 862.795 uV 18:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.729 uVs 18:14:58 Integrated Voltage Measurement... 18:15:07 Voltage Offset Correction: v_off_ini = 853.270 uV, v_off_fin = 847.573 uV 18:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.801 uVs 18:15:07 Integrated Voltage Measurement... 18:15:16 Voltage Offset Correction: v_off_ini = 852.360 uV, v_off_fin = 843.579 uV 18:15:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.780 uVs 18:15:16 Integrated Voltage Measurement... 18:15:25 Voltage Offset Correction: v_off_ini = 857.811 uV, v_off_fin = 842.988 uV 18:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.076 uVs 18:15:25 Integrated Voltage Measurement... 18:15:34 Voltage Offset Correction: v_off_ini = 859.481 uV, v_off_fin = 860.497 uV 18:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.817 uVs 18:15:38 I1X Average and RMS of Measurements VT = -92.802 +- 2.968 uVs I1X = 18.561 +- 0.595 uTm 18:15:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:15:45 Integrated Voltage Measurement... 18:15:54 Voltage Offset Correction: v_off_ini = 849.903 uV, v_off_fin = 835.259 uV 18:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.571 uVs 18:15:54 Integrated Voltage Measurement... 18:16:03 Voltage Offset Correction: v_off_ini = 842.692 uV, v_off_fin = 842.194 uV 18:16:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.151 uVs 18:16:03 Integrated Voltage Measurement... 18:16:12 Voltage Offset Correction: v_off_ini = 839.267 uV, v_off_fin = 839.649 uV 18:16:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.769 uVs 18:16:12 Integrated Voltage Measurement... 18:16:21 Voltage Offset Correction: v_off_ini = 852.585 uV, v_off_fin = 865.707 uV 18:16:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.226 uVs 18:16:21 Integrated Voltage Measurement... 18:16:30 Voltage Offset Correction: v_off_ini = 859.900 uV, v_off_fin = 845.516 uV 18:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -166.366 uVs 18:16:30 Integrated Voltage Measurement... 18:16:39 Voltage Offset Correction: v_off_ini = 854.547 uV, v_off_fin = 874.699 uV 18:16:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.430 uVs 18:16:43 I1Y Average and RMS of Measurements VT = -175.752 +- 3.367 uVs I1Y = -35.150 +- 0.672 uTm 18:16:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:16:48 Integrated Voltage Measurement... 18:16:57 Voltage Offset Correction: v_off_ini = 841.663 uV, v_off_fin = 846.520 uV 18:16:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.835 uVs 18:16:57 Integrated Voltage Measurement... 18:17:06 Voltage Offset Correction: v_off_ini = 846.011 uV, v_off_fin = 852.269 uV 18:17:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.257 uVs 18:17:07 Integrated Voltage Measurement... 18:17:15 Voltage Offset Correction: v_off_ini = 864.696 uV, v_off_fin = 854.440 uV 18:17:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.390 uVs 18:17:16 Integrated Voltage Measurement... 18:17:25 Voltage Offset Correction: v_off_ini = 844.301 uV, v_off_fin = 845.939 uV 18:17:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.540 uVs 18:17:25 Integrated Voltage Measurement... 18:17:34 Voltage Offset Correction: v_off_ini = 845.653 uV, v_off_fin = 854.425 uV 18:17:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -90.557 uVs 18:17:34 Integrated Voltage Measurement... 18:17:43 Voltage Offset Correction: v_off_ini = 858.844 uV, v_off_fin = 861.134 uV 18:17:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.417 uVs 18:17:45 I2X Average and RMS of Measurements VT = -71.333 +- 2.041 uVs I2X = 6.563 +- 0.188 uTm^2 18:17:48 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:17:50 Integrated Voltage Measurement... 18:17:59 Voltage Offset Correction: v_off_ini = 846.905 uV, v_off_fin = 847.562 uV 18:17:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.318 uVs 18:17:59 Integrated Voltage Measurement... 18:18:08 Voltage Offset Correction: v_off_ini = 846.002 uV, v_off_fin = 851.249 uV 18:18:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.474 uVs 18:18:08 Integrated Voltage Measurement... 18:18:17 Voltage Offset Correction: v_off_ini = 848.722 uV, v_off_fin = 864.462 uV 18:18:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.082 uVs 18:18:17 Integrated Voltage Measurement... 18:18:26 Voltage Offset Correction: v_off_ini = 869.357 uV, v_off_fin = 857.187 uV 18:18:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.197 uVs 18:18:26 Integrated Voltage Measurement... 18:18:35 Voltage Offset Correction: v_off_ini = 877.022 uV, v_off_fin = 866.241 uV 18:18:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.368 uVs 18:18:35 Integrated Voltage Measurement... 18:18:44 Voltage Offset Correction: v_off_ini = 863.790 uV, v_off_fin = 868.974 uV 18:18:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 229.354 uVs 18:18:47 I2Y Average and RMS of Measurements VT = -224.799 +- 4.687 uVs I2Y = -20.682 +- 0.432 uTm^2 18:19:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:19:08 Integrated Voltage Measurement... 18:19:17 Voltage Offset Correction: v_off_ini = 872.384 uV, v_off_fin = 861.641 uV 18:19:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -116.713 uVs 18:19:17 Integrated Voltage Measurement... 18:19:26 Voltage Offset Correction: v_off_ini = 869.977 uV, v_off_fin = 862.266 uV 18:19:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.050 uVs 18:19:26 Integrated Voltage Measurement... 18:19:35 Voltage Offset Correction: v_off_ini = 871.175 uV, v_off_fin = 851.135 uV 18:19:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.364 uVs 18:19:35 Integrated Voltage Measurement... 18:19:44 Voltage Offset Correction: v_off_ini = 853.885 uV, v_off_fin = 867.991 uV 18:19:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.134 uVs 18:19:44 Integrated Voltage Measurement... 18:19:53 Voltage Offset Correction: v_off_ini = 859.876 uV, v_off_fin = 862.912 uV 18:19:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.212 uVs 18:19:53 Integrated Voltage Measurement... 18:20:02 Voltage Offset Correction: v_off_ini = 867.125 uV, v_off_fin = 858.557 uV 18:20:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.922 uVs 18:20:07 I1X Average and RMS of Measurements VT = -105.232 +- 7.561 uVs I1X = 21.048 +- 1.514 uTm 18:20:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:20:13 Integrated Voltage Measurement... 18:20:22 Voltage Offset Correction: v_off_ini = 856.030 uV, v_off_fin = 844.413 uV 18:20:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.151 uVs 18:20:22 Integrated Voltage Measurement... 18:20:31 Voltage Offset Correction: v_off_ini = 857.062 uV, v_off_fin = 873.814 uV 18:20:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.339 uVs 18:20:31 Integrated Voltage Measurement... 18:20:40 Voltage Offset Correction: v_off_ini = 860.359 uV, v_off_fin = 860.687 uV 18:20:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.727 uVs 18:20:40 Integrated Voltage Measurement... 18:20:49 Voltage Offset Correction: v_off_ini = 859.283 uV, v_off_fin = 863.352 uV 18:20:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.906 uVs 18:20:49 Integrated Voltage Measurement... 18:20:58 Voltage Offset Correction: v_off_ini = 860.163 uV, v_off_fin = 850.867 uV 18:20:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.566 uVs 18:20:58 Integrated Voltage Measurement... 18:21:07 Voltage Offset Correction: v_off_ini = 853.697 uV, v_off_fin = 862.827 uV 18:21:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.286 uVs 18:21:12 I1Y Average and RMS of Measurements VT = -152.329 +- 4.733 uVs I1Y = -30.466 +- 0.947 uTm 18:21:17 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:21:19 Integrated Voltage Measurement... 18:21:28 Voltage Offset Correction: v_off_ini = 834.222 uV, v_off_fin = 824.381 uV 18:21:28 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -88.562 uVs 18:21:28 Integrated Voltage Measurement... 18:21:37 Voltage Offset Correction: v_off_ini = 849.620 uV, v_off_fin = 855.066 uV 18:21:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.024 uVs 18:21:37 Integrated Voltage Measurement... 18:21:46 Voltage Offset Correction: v_off_ini = 839.916 uV, v_off_fin = 823.840 uV 18:21:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -91.697 uVs 18:21:46 Integrated Voltage Measurement... 18:21:55 Voltage Offset Correction: v_off_ini = 833.501 uV, v_off_fin = 849.533 uV 18:21:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.195 uVs 18:21:56 Integrated Voltage Measurement... 18:22:04 Voltage Offset Correction: v_off_ini = 846.201 uV, v_off_fin = 828.057 uV 18:22:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.563 uVs 18:22:05 Integrated Voltage Measurement... 18:22:14 Voltage Offset Correction: v_off_ini = 841.331 uV, v_off_fin = 847.763 uV 18:22:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.811 uVs 18:22:16 I2X Average and RMS of Measurements VT = -87.142 +- 1.547 uVs I2X = 8.017 +- 0.142 uTm^2 18:22:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:22:24 Integrated Voltage Measurement... 18:22:33 Voltage Offset Correction: v_off_ini = 842.731 uV, v_off_fin = 847.268 uV 18:22:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.911 uVs 18:22:33 Integrated Voltage Measurement... 18:22:42 Voltage Offset Correction: v_off_ini = 844.670 uV, v_off_fin = 841.812 uV 18:22:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.361 uVs 18:22:42 Integrated Voltage Measurement... 18:22:51 Voltage Offset Correction: v_off_ini = 847.210 uV, v_off_fin = 844.290 uV 18:22:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.853 uVs 18:22:51 Integrated Voltage Measurement... 18:23:00 Voltage Offset Correction: v_off_ini = 845.748 uV, v_off_fin = 849.655 uV 18:23:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.714 uVs 18:23:00 Integrated Voltage Measurement... 18:23:09 Voltage Offset Correction: v_off_ini = 844.044 uV, v_off_fin = 842.803 uV 18:23:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.999 uVs 18:23:09 Integrated Voltage Measurement... 18:23:18 Voltage Offset Correction: v_off_ini = 848.646 uV, v_off_fin = 852.993 uV 18:23:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 187.807 uVs 18:23:20 I2Y Average and RMS of Measurements VT = -190.274 +- 3.421 uVs I2Y = -17.505 +- 0.315 uTm^2 18:23:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:23:29 Integrated Voltage Measurement... 18:23:38 Voltage Offset Correction: v_off_ini = 873.101 uV, v_off_fin = 871.267 uV 18:23:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -128.067 uVs 18:23:38 Integrated Voltage Measurement... 18:23:47 Voltage Offset Correction: v_off_ini = 863.288 uV, v_off_fin = 867.649 uV 18:23:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.757 uVs 18:23:47 Integrated Voltage Measurement... 18:23:56 Voltage Offset Correction: v_off_ini = 866.464 uV, v_off_fin = 861.032 uV 18:23:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.363 uVs 18:23:56 Integrated Voltage Measurement... 18:24:05 Voltage Offset Correction: v_off_ini = 874.257 uV, v_off_fin = 891.009 uV 18:24:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.278 uVs 18:24:05 Integrated Voltage Measurement... 18:24:14 Voltage Offset Correction: v_off_ini = 879.071 uV, v_off_fin = 871.431 uV 18:24:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.953 uVs 18:24:14 Integrated Voltage Measurement... 18:24:23 Voltage Offset Correction: v_off_ini = 886.420 uV, v_off_fin = 891.630 uV 18:24:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.232 uVs 18:24:28 I1X Average and RMS of Measurements VT = -109.275 +- 12.355 uVs I1X = 21.856 +- 2.472 uTm 18:24:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:24:34 Integrated Voltage Measurement... 18:24:43 Voltage Offset Correction: v_off_ini = 889.145 uV, v_off_fin = 877.048 uV 18:24:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.278 uVs 18:24:43 Integrated Voltage Measurement... 18:24:52 Voltage Offset Correction: v_off_ini = 880.259 uV, v_off_fin = 878.961 uV 18:24:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.759 uVs 18:24:52 Integrated Voltage Measurement... 18:25:01 Voltage Offset Correction: v_off_ini = 867.486 uV, v_off_fin = 859.755 uV 18:25:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.911 uVs 18:25:01 Integrated Voltage Measurement... 18:25:10 Voltage Offset Correction: v_off_ini = 866.323 uV, v_off_fin = 891.287 uV 18:25:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.835 uVs 18:25:10 Integrated Voltage Measurement... 18:25:19 Voltage Offset Correction: v_off_ini = 869.247 uV, v_off_fin = 865.747 uV 18:25:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.562 uVs 18:25:19 Integrated Voltage Measurement... 18:25:28 Voltage Offset Correction: v_off_ini = 869.995 uV, v_off_fin = 882.927 uV 18:25:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.361 uVs 18:25:33 I1Y Average and RMS of Measurements VT = -167.618 +- 5.291 uVs I1Y = -33.524 +- 1.058 uTm 18:25:38 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:25:40 Integrated Voltage Measurement... 18:25:49 Voltage Offset Correction: v_off_ini = 878.752 uV, v_off_fin = 875.263 uV 18:25:49 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -93.787 uVs 18:25:49 Integrated Voltage Measurement... 18:25:58 Voltage Offset Correction: v_off_ini = 844.622 uV, v_off_fin = 847.686 uV 18:25:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 71.129 uVs 18:25:58 Integrated Voltage Measurement... 18:26:07 Voltage Offset Correction: v_off_ini = 850.361 uV, v_off_fin = 852.514 uV 18:26:07 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -83.883 uVs 18:26:07 Integrated Voltage Measurement... 18:26:16 Voltage Offset Correction: v_off_ini = 860.918 uV, v_off_fin = 867.027 uV 18:26:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.380 uVs 18:26:16 Integrated Voltage Measurement... 18:26:25 Voltage Offset Correction: v_off_ini = 854.655 uV, v_off_fin = 851.716 uV 18:26:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.431 uVs 18:26:26 Integrated Voltage Measurement... 18:26:35 Voltage Offset Correction: v_off_ini = 856.699 uV, v_off_fin = 860.396 uV 18:26:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.955 uVs 18:26:37 I2X Average and RMS of Measurements VT = -84.594 +- 5.936 uVs I2X = 7.783 +- 0.546 uTm^2 18:26:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:26:45 Integrated Voltage Measurement... 18:26:54 Voltage Offset Correction: v_off_ini = 855.306 uV, v_off_fin = 861.892 uV 18:26:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.249 uVs 18:26:54 Integrated Voltage Measurement... 18:27:03 Voltage Offset Correction: v_off_ini = 848.248 uV, v_off_fin = 864.223 uV 18:27:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.089 uVs 18:27:03 Integrated Voltage Measurement... 18:27:12 Voltage Offset Correction: v_off_ini = 863.208 uV, v_off_fin = 870.404 uV 18:27:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.735 uVs 18:27:12 Integrated Voltage Measurement... 18:27:21 Voltage Offset Correction: v_off_ini = 875.051 uV, v_off_fin = 854.920 uV 18:27:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.895 uVs 18:27:21 Integrated Voltage Measurement... 18:27:30 Voltage Offset Correction: v_off_ini = 850.407 uV, v_off_fin = 856.274 uV 18:27:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.538 uVs 18:27:30 Integrated Voltage Measurement... 18:27:39 Voltage Offset Correction: v_off_ini = 854.114 uV, v_off_fin = 849.570 uV 18:27:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.720 uVs 18:27:41 I2Y Average and RMS of Measurements VT = -203.205 +- 0.763 uVs I2Y = -18.695 +- 0.070 uTm^2 18:27:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:27:50 Integrated Voltage Measurement... 18:27:59 Voltage Offset Correction: v_off_ini = 846.793 uV, v_off_fin = 851.979 uV 18:27:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.196 uVs 18:27:59 Integrated Voltage Measurement... 18:28:08 Voltage Offset Correction: v_off_ini = 848.055 uV, v_off_fin = 864.311 uV 18:28:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.592 uVs 18:28:08 Integrated Voltage Measurement... 18:28:17 Voltage Offset Correction: v_off_ini = 851.854 uV, v_off_fin = 847.861 uV 18:28:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.650 uVs 18:28:17 Integrated Voltage Measurement... 18:28:26 Voltage Offset Correction: v_off_ini = 835.903 uV, v_off_fin = 854.955 uV 18:28:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.076 uVs 18:28:26 Integrated Voltage Measurement... 18:28:35 Voltage Offset Correction: v_off_ini = 852.791 uV, v_off_fin = 846.652 uV 18:28:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.884 uVs 18:28:35 Integrated Voltage Measurement... 18:28:44 Voltage Offset Correction: v_off_ini = 867.538 uV, v_off_fin = 881.543 uV 18:28:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.037 uVs 18:28:49 I1X Average and RMS of Measurements VT = -106.072 +- 2.396 uVs I1X = 21.214 +- 0.479 uTm 18:28:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:28:55 Integrated Voltage Measurement... 18:29:04 Voltage Offset Correction: v_off_ini = 862.518 uV, v_off_fin = 854.446 uV 18:29:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.181 uVs 18:29:04 Integrated Voltage Measurement... 18:29:13 Voltage Offset Correction: v_off_ini = 865.682 uV, v_off_fin = 876.020 uV 18:29:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.088 uVs 18:29:13 Integrated Voltage Measurement... 18:29:22 Voltage Offset Correction: v_off_ini = 880.146 uV, v_off_fin = 855.175 uV 18:29:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.911 uVs 18:29:22 Integrated Voltage Measurement... 18:29:31 Voltage Offset Correction: v_off_ini = 873.918 uV, v_off_fin = 880.434 uV 18:29:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.688 uVs 18:29:31 Integrated Voltage Measurement... 18:29:40 Voltage Offset Correction: v_off_ini = 873.532 uV, v_off_fin = 867.650 uV 18:29:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.607 uVs 18:29:40 Integrated Voltage Measurement... 18:29:49 Voltage Offset Correction: v_off_ini = 866.798 uV, v_off_fin = 876.274 uV 18:29:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.544 uVs 18:29:54 I1Y Average and RMS of Measurements VT = -176.670 +- 6.727 uVs I1Y = -35.334 +- 1.345 uTm 18:29:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:30:01 Integrated Voltage Measurement... 18:30:10 Voltage Offset Correction: v_off_ini = 862.580 uV, v_off_fin = 866.993 uV 18:30:10 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -77.844 uVs 18:30:10 Integrated Voltage Measurement... 18:30:19 Voltage Offset Correction: v_off_ini = 874.214 uV, v_off_fin = 882.070 uV 18:30:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.571 uVs 18:30:19 Integrated Voltage Measurement... 18:30:28 Voltage Offset Correction: v_off_ini = 878.194 uV, v_off_fin = 861.696 uV 18:30:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.986 uVs 18:30:28 Integrated Voltage Measurement... 18:30:37 Voltage Offset Correction: v_off_ini = 875.596 uV, v_off_fin = 875.033 uV 18:30:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.408 uVs 18:30:38 Integrated Voltage Measurement... 18:30:46 Voltage Offset Correction: v_off_ini = 881.809 uV, v_off_fin = 866.318 uV 18:30:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.933 uVs 18:30:47 Integrated Voltage Measurement... 18:30:56 Voltage Offset Correction: v_off_ini = 877.020 uV, v_off_fin = 885.335 uV 18:30:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.875 uVs 18:30:58 I2X Average and RMS of Measurements VT = -83.436 +- 5.568 uVs I2X = 7.676 +- 0.513 uTm^2 18:31:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:31:06 Integrated Voltage Measurement... 18:31:15 Voltage Offset Correction: v_off_ini = 871.534 uV, v_off_fin = 867.872 uV 18:31:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.764 uVs 18:31:15 Integrated Voltage Measurement... 18:31:24 Voltage Offset Correction: v_off_ini = 871.870 uV, v_off_fin = 876.765 uV 18:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.905 uVs 18:31:24 Integrated Voltage Measurement... 18:31:33 Voltage Offset Correction: v_off_ini = 875.935 uV, v_off_fin = 885.851 uV 18:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.306 uVs 18:31:33 Integrated Voltage Measurement... 18:31:42 Voltage Offset Correction: v_off_ini = 891.758 uV, v_off_fin = 884.073 uV 18:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.406 uVs 18:31:42 Integrated Voltage Measurement... 18:31:51 Voltage Offset Correction: v_off_ini = 896.163 uV, v_off_fin = 894.445 uV 18:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.403 uVs 18:31:51 Integrated Voltage Measurement... 18:32:00 Voltage Offset Correction: v_off_ini = 890.022 uV, v_off_fin = 886.574 uV 18:32:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.466 uVs 18:32:02 I2Y Average and RMS of Measurements VT = -209.875 +- 3.234 uVs I2Y = -19.309 +- 0.298 uTm^2 18:32:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:32:11 Integrated Voltage Measurement... 18:32:20 Voltage Offset Correction: v_off_ini = 867.605 uV, v_off_fin = 868.527 uV 18:32:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.855 uVs 18:32:20 Integrated Voltage Measurement... 18:32:29 Voltage Offset Correction: v_off_ini = 871.665 uV, v_off_fin = 875.938 uV 18:32:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.106 uVs 18:32:29 Integrated Voltage Measurement... 18:32:38 Voltage Offset Correction: v_off_ini = 884.800 uV, v_off_fin = 881.650 uV 18:32:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.061 uVs 18:32:38 Integrated Voltage Measurement... 18:32:47 Voltage Offset Correction: v_off_ini = 882.805 uV, v_off_fin = 874.679 uV 18:32:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.886 uVs 18:32:47 Integrated Voltage Measurement... 18:32:56 Voltage Offset Correction: v_off_ini = 872.187 uV, v_off_fin = 863.916 uV 18:32:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.931 uVs 18:32:56 Integrated Voltage Measurement... 18:33:05 Voltage Offset Correction: v_off_ini = 885.905 uV, v_off_fin = 879.794 uV 18:33:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.132 uVs 18:33:10 I1X Average and RMS of Measurements VT = -109.329 +- 3.693 uVs I1X = 21.866 +- 0.738 uTm 18:33:12 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:33:16 Integrated Voltage Measurement... 18:33:25 Voltage Offset Correction: v_off_ini = 864.874 uV, v_off_fin = 876.878 uV 18:33:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.289 uVs 18:33:25 Integrated Voltage Measurement... 18:33:34 Voltage Offset Correction: v_off_ini = 867.979 uV, v_off_fin = 885.942 uV 18:33:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.081 uVs 18:33:34 Integrated Voltage Measurement... 18:33:43 Voltage Offset Correction: v_off_ini = 858.088 uV, v_off_fin = 872.333 uV 18:33:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.717 uVs 18:33:43 Integrated Voltage Measurement... 18:33:52 Voltage Offset Correction: v_off_ini = 880.742 uV, v_off_fin = 883.801 uV 18:33:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.820 uVs 18:33:53 Integrated Voltage Measurement... 18:34:01 Voltage Offset Correction: v_off_ini = 877.051 uV, v_off_fin = 861.107 uV 18:34:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.144 uVs 18:34:01 Integrated Voltage Measurement... 18:34:10 Voltage Offset Correction: v_off_ini = 872.784 uV, v_off_fin = 878.343 uV 18:34:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.104 uVs 18:34:15 I1Y Average and RMS of Measurements VT = -178.692 +- 12.299 uVs I1Y = -35.738 +- 2.460 uTm 18:34:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:34:22 Integrated Voltage Measurement... 18:34:31 Voltage Offset Correction: v_off_ini = 869.877 uV, v_off_fin = 863.465 uV 18:34:31 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -77.494 uVs 18:34:31 Integrated Voltage Measurement... 18:34:40 Voltage Offset Correction: v_off_ini = 901.151 uV, v_off_fin = 903.403 uV 18:34:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.916 uVs 18:34:41 Integrated Voltage Measurement... 18:34:49 Voltage Offset Correction: v_off_ini = 868.656 uV, v_off_fin = 879.923 uV 18:34:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.796 uVs 18:34:50 Integrated Voltage Measurement... 18:34:59 Voltage Offset Correction: v_off_ini = 875.526 uV, v_off_fin = 899.186 uV 18:34:59 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.628 uVs 18:34:59 Integrated Voltage Measurement... 18:35:08 Voltage Offset Correction: v_off_ini = 885.666 uV, v_off_fin = 870.235 uV 18:35:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.278 uVs 18:35:08 Integrated Voltage Measurement... 18:35:17 Voltage Offset Correction: v_off_ini = 887.149 uV, v_off_fin = 894.971 uV 18:35:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 74.730 uVs 18:35:19 I2X Average and RMS of Measurements VT = -75.140 +- 3.650 uVs I2X = 6.913 +- 0.336 uTm^2 18:35:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:35:27 Integrated Voltage Measurement... 18:35:36 Voltage Offset Correction: v_off_ini = 890.596 uV, v_off_fin = 885.277 uV 18:35:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.930 uVs 18:35:36 Integrated Voltage Measurement... 18:35:45 Voltage Offset Correction: v_off_ini = 894.892 uV, v_off_fin = 901.945 uV 18:35:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.571 uVs 18:35:45 Integrated Voltage Measurement... 18:35:54 Voltage Offset Correction: v_off_ini = 884.538 uV, v_off_fin = 889.915 uV 18:35:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.919 uVs 18:35:54 Integrated Voltage Measurement... 18:36:03 Voltage Offset Correction: v_off_ini = 888.441 uV, v_off_fin = 881.861 uV 18:36:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.923 uVs 18:36:03 Integrated Voltage Measurement... 18:36:12 Voltage Offset Correction: v_off_ini = 889.065 uV, v_off_fin = 883.154 uV 18:36:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.102 uVs 18:36:12 Integrated Voltage Measurement... 18:36:21 Voltage Offset Correction: v_off_ini = 881.870 uV, v_off_fin = 882.431 uV 18:36:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.101 uVs 18:36:23 I2Y Average and RMS of Measurements VT = -217.591 +- 4.862 uVs I2Y = -20.018 +- 0.447 uTm^2 18:36:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:36:32 Integrated Voltage Measurement... 18:36:41 Voltage Offset Correction: v_off_ini = 894.660 uV, v_off_fin = 875.311 uV 18:36:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -113.507 uVs 18:36:41 Integrated Voltage Measurement... 18:36:50 Voltage Offset Correction: v_off_ini = 884.930 uV, v_off_fin = 894.738 uV 18:36:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.106 uVs 18:36:50 Integrated Voltage Measurement... 18:36:59 Voltage Offset Correction: v_off_ini = 895.928 uV, v_off_fin = 888.583 uV 18:36:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -94.686 uVs 18:36:59 Integrated Voltage Measurement... 18:37:08 Voltage Offset Correction: v_off_ini = 876.111 uV, v_off_fin = 885.624 uV 18:37:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 103.984 uVs 18:37:08 Integrated Voltage Measurement... 18:37:17 Voltage Offset Correction: v_off_ini = 890.582 uV, v_off_fin = 886.299 uV 18:37:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.445 uVs 18:37:17 Integrated Voltage Measurement... 18:37:26 Voltage Offset Correction: v_off_ini = 902.133 uV, v_off_fin = 909.075 uV 18:37:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.763 uVs 18:37:31 I1X Average and RMS of Measurements VT = -98.249 +- 4.637 uVs I1X = 19.652 +- 0.929 uTm 18:37:33 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:37:37 Integrated Voltage Measurement... 18:37:46 Voltage Offset Correction: v_off_ini = 881.978 uV, v_off_fin = 877.346 uV 18:37:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.868 uVs 18:37:46 Integrated Voltage Measurement... 18:37:55 Voltage Offset Correction: v_off_ini = 888.756 uV, v_off_fin = 890.282 uV 18:37:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.960 uVs 18:37:55 Integrated Voltage Measurement... 18:38:04 Voltage Offset Correction: v_off_ini = 887.061 uV, v_off_fin = 888.735 uV 18:38:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.695 uVs 18:38:04 Integrated Voltage Measurement... 18:38:13 Voltage Offset Correction: v_off_ini = 895.999 uV, v_off_fin = 899.088 uV 18:38:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.567 uVs 18:38:13 Integrated Voltage Measurement... 18:38:22 Voltage Offset Correction: v_off_ini = 879.284 uV, v_off_fin = 866.860 uV 18:38:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.660 uVs 18:38:22 Integrated Voltage Measurement... 18:38:31 Voltage Offset Correction: v_off_ini = 880.438 uV, v_off_fin = 894.253 uV 18:38:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.477 uVs 18:38:36 I1Y Average and RMS of Measurements VT = -187.871 +- 3.215 uVs I1Y = -37.574 +- 0.643 uTm 18:38:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:38:43 Integrated Voltage Measurement... 18:38:52 Voltage Offset Correction: v_off_ini = 893.919 uV, v_off_fin = 887.765 uV 18:38:52 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -75.584 uVs 18:38:52 Integrated Voltage Measurement... 18:39:01 Voltage Offset Correction: v_off_ini = 897.707 uV, v_off_fin = 904.203 uV 18:39:01 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 89.202 uVs 18:39:01 Integrated Voltage Measurement... 18:39:10 Voltage Offset Correction: v_off_ini = 883.459 uV, v_off_fin = 875.544 uV 18:39:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.646 uVs 18:39:10 Integrated Voltage Measurement... 18:39:19 Voltage Offset Correction: v_off_ini = 883.070 uV, v_off_fin = 885.079 uV 18:39:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.133 uVs 18:39:19 Integrated Voltage Measurement... 18:39:28 Voltage Offset Correction: v_off_ini = 878.663 uV, v_off_fin = 880.161 uV 18:39:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.094 uVs 18:39:29 Integrated Voltage Measurement... 18:39:38 Voltage Offset Correction: v_off_ini = 872.211 uV, v_off_fin = 896.559 uV 18:39:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.949 uVs 18:39:40 I2X Average and RMS of Measurements VT = -73.268 +- 14.436 uVs I2X = 6.741 +- 1.328 uTm^2 18:39:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:39:48 Integrated Voltage Measurement... 18:39:57 Voltage Offset Correction: v_off_ini = 885.960 uV, v_off_fin = 880.519 uV 18:39:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.093 uVs 18:39:57 Integrated Voltage Measurement... 18:40:06 Voltage Offset Correction: v_off_ini = 881.931 uV, v_off_fin = 884.143 uV 18:40:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.956 uVs 18:40:06 Integrated Voltage Measurement... 18:40:15 Voltage Offset Correction: v_off_ini = 879.267 uV, v_off_fin = 878.327 uV 18:40:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.290 uVs 18:40:15 Integrated Voltage Measurement... 18:40:24 Voltage Offset Correction: v_off_ini = 877.460 uV, v_off_fin = 890.952 uV 18:40:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.885 uVs 18:40:24 Integrated Voltage Measurement... 18:40:33 Voltage Offset Correction: v_off_ini = 870.984 uV, v_off_fin = 876.099 uV 18:40:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.702 uVs 18:40:33 Integrated Voltage Measurement... 18:40:42 Voltage Offset Correction: v_off_ini = 885.437 uV, v_off_fin = 879.091 uV 18:40:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.688 uVs 18:40:44 I2Y Average and RMS of Measurements VT = -221.936 +- 2.829 uVs I2Y = -20.418 +- 0.260 uTm^2 18:40:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:40:56 Integrated Voltage Measurement... 18:41:05 Voltage Offset Correction: v_off_ini = 887.327 uV, v_off_fin = 879.515 uV 18:41:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -125.588 uVs 18:41:05 Integrated Voltage Measurement... 18:41:14 Voltage Offset Correction: v_off_ini = 875.941 uV, v_off_fin = 877.550 uV 18:41:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.509 uVs 18:41:14 Integrated Voltage Measurement... 18:41:23 Voltage Offset Correction: v_off_ini = 879.625 uV, v_off_fin = 869.425 uV 18:41:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.317 uVs 18:41:23 Integrated Voltage Measurement... 18:41:32 Voltage Offset Correction: v_off_ini = 858.927 uV, v_off_fin = 860.026 uV 18:41:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.574 uVs 18:41:32 Integrated Voltage Measurement... 18:41:41 Voltage Offset Correction: v_off_ini = 861.693 uV, v_off_fin = 867.790 uV 18:41:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.665 uVs 18:41:41 Integrated Voltage Measurement... 18:41:50 Voltage Offset Correction: v_off_ini = 880.323 uV, v_off_fin = 865.522 uV 18:41:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.887 uVs 18:41:55 I1X Average and RMS of Measurements VT = -115.090 +- 4.590 uVs I1X = 23.018 +- 0.918 uTm 18:41:57 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:42:01 Integrated Voltage Measurement... 18:42:10 Voltage Offset Correction: v_off_ini = 876.731 uV, v_off_fin = 861.781 uV 18:42:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.366 uVs 18:42:10 Integrated Voltage Measurement... 18:42:19 Voltage Offset Correction: v_off_ini = 857.000 uV, v_off_fin = 867.569 uV 18:42:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.240 uVs 18:42:19 Integrated Voltage Measurement... 18:42:28 Voltage Offset Correction: v_off_ini = 875.672 uV, v_off_fin = 865.508 uV 18:42:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.977 uVs 18:42:28 Integrated Voltage Measurement... 18:42:37 Voltage Offset Correction: v_off_ini = 868.792 uV, v_off_fin = 881.130 uV 18:42:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.545 uVs 18:42:37 Integrated Voltage Measurement... 18:42:46 Voltage Offset Correction: v_off_ini = 874.475 uV, v_off_fin = 859.615 uV 18:42:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.947 uVs 18:42:46 Integrated Voltage Measurement... 18:42:55 Voltage Offset Correction: v_off_ini = 864.172 uV, v_off_fin = 864.188 uV 18:42:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.864 uVs 18:43:00 I1Y Average and RMS of Measurements VT = -174.323 +- 3.200 uVs I1Y = -34.865 +- 0.640 uTm 18:43:02 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:43:05 Integrated Voltage Measurement... 18:43:14 Voltage Offset Correction: v_off_ini = 870.664 uV, v_off_fin = 854.370 uV 18:43:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.114 uVs 18:43:14 Integrated Voltage Measurement... 18:43:23 Voltage Offset Correction: v_off_ini = 869.030 uV, v_off_fin = 866.454 uV 18:43:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.105 uVs 18:43:23 Integrated Voltage Measurement... 18:43:32 Voltage Offset Correction: v_off_ini = 866.466 uV, v_off_fin = 856.306 uV 18:43:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.875 uVs 18:43:32 Integrated Voltage Measurement... 18:43:41 Voltage Offset Correction: v_off_ini = 869.007 uV, v_off_fin = 875.649 uV 18:43:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.593 uVs 18:43:41 Integrated Voltage Measurement... 18:43:50 Voltage Offset Correction: v_off_ini = 878.265 uV, v_off_fin = 873.155 uV 18:43:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.816 uVs 18:43:50 Integrated Voltage Measurement... 18:43:59 Voltage Offset Correction: v_off_ini = 866.389 uV, v_off_fin = 882.324 uV 18:43:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.927 uVs 18:44:01 I2X Average and RMS of Measurements VT = -84.905 +- 1.399 uVs I2X = 7.811 +- 0.129 uTm^2 18:44:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:44:07 Integrated Voltage Measurement... 18:44:16 Voltage Offset Correction: v_off_ini = 878.718 uV, v_off_fin = 881.426 uV 18:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.370 uVs 18:44:16 Integrated Voltage Measurement... 18:44:25 Voltage Offset Correction: v_off_ini = 870.541 uV, v_off_fin = 863.400 uV 18:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.273 uVs 18:44:25 Integrated Voltage Measurement... 18:44:34 Voltage Offset Correction: v_off_ini = 871.295 uV, v_off_fin = 865.042 uV 18:44:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -210.748 uVs 18:44:34 Integrated Voltage Measurement... 18:44:43 Voltage Offset Correction: v_off_ini = 865.995 uV, v_off_fin = 863.538 uV 18:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.754 uVs 18:44:43 Integrated Voltage Measurement... 18:44:52 Voltage Offset Correction: v_off_ini = 870.663 uV, v_off_fin = 869.779 uV 18:44:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.878 uVs 18:44:52 Integrated Voltage Measurement... 18:45:01 Voltage Offset Correction: v_off_ini = 851.968 uV, v_off_fin = 849.913 uV 18:45:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.415 uVs 18:45:03 I2Y Average and RMS of Measurements VT = -213.073 +- 4.940 uVs I2Y = -19.603 +- 0.455 uTm^2 18:45:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:45:11 Integrated Voltage Measurement... 18:45:20 Voltage Offset Correction: v_off_ini = 847.097 uV, v_off_fin = 844.059 uV 18:45:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -91.194 uVs 18:45:21 Integrated Voltage Measurement... 18:45:29 Voltage Offset Correction: v_off_ini = 852.752 uV, v_off_fin = 845.464 uV 18:45:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.681 uVs 18:45:30 Integrated Voltage Measurement... 18:45:39 Voltage Offset Correction: v_off_ini = 845.992 uV, v_off_fin = 852.618 uV 18:45:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.399 uVs 18:45:39 Integrated Voltage Measurement... 18:45:48 Voltage Offset Correction: v_off_ini = 847.568 uV, v_off_fin = 850.612 uV 18:45:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.697 uVs 18:45:48 Integrated Voltage Measurement... 18:45:57 Voltage Offset Correction: v_off_ini = 847.745 uV, v_off_fin = 849.034 uV 18:45:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.217 uVs 18:45:57 Integrated Voltage Measurement... 18:46:06 Voltage Offset Correction: v_off_ini = 854.763 uV, v_off_fin = 856.185 uV 18:46:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.595 uVs 18:46:10 I1X Average and RMS of Measurements VT = -108.297 +- 9.213 uVs I1X = 21.660 +- 1.842 uTm 18:46:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:46:17 Integrated Voltage Measurement... 18:46:26 Voltage Offset Correction: v_off_ini = 859.721 uV, v_off_fin = 842.075 uV 18:46:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.035 uVs 18:46:26 Integrated Voltage Measurement... 18:46:35 Voltage Offset Correction: v_off_ini = 838.618 uV, v_off_fin = 856.430 uV 18:46:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.117 uVs 18:46:35 Integrated Voltage Measurement... 18:46:44 Voltage Offset Correction: v_off_ini = 853.731 uV, v_off_fin = 835.722 uV 18:46:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.615 uVs 18:46:44 Integrated Voltage Measurement... 18:46:53 Voltage Offset Correction: v_off_ini = 845.968 uV, v_off_fin = 856.228 uV 18:46:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.879 uVs 18:46:53 Integrated Voltage Measurement... 18:47:02 Voltage Offset Correction: v_off_ini = 833.165 uV, v_off_fin = 834.220 uV 18:47:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.725 uVs 18:47:02 Integrated Voltage Measurement... 18:47:11 Voltage Offset Correction: v_off_ini = 851.247 uV, v_off_fin = 849.932 uV 18:47:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.104 uVs 18:47:15 I1Y Average and RMS of Measurements VT = -176.746 +- 3.731 uVs I1Y = -35.349 +- 0.746 uTm 18:47:17 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:47:20 Integrated Voltage Measurement... 18:47:29 Voltage Offset Correction: v_off_ini = 843.861 uV, v_off_fin = 839.547 uV 18:47:29 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -116.032 uVs 18:47:29 Integrated Voltage Measurement... 18:47:38 Voltage Offset Correction: v_off_ini = 859.580 uV, v_off_fin = 859.529 uV 18:47:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.784 uVs 18:47:38 Integrated Voltage Measurement... 18:47:47 Voltage Offset Correction: v_off_ini = 852.504 uV, v_off_fin = 842.325 uV 18:47:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -104.392 uVs 18:47:47 Integrated Voltage Measurement... 18:47:56 Voltage Offset Correction: v_off_ini = 858.471 uV, v_off_fin = 868.508 uV 18:47:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.847 uVs 18:47:56 Integrated Voltage Measurement... 18:48:05 Voltage Offset Correction: v_off_ini = 863.779 uV, v_off_fin = 857.146 uV 18:48:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.900 uVs 18:48:05 Integrated Voltage Measurement... 18:48:14 Voltage Offset Correction: v_off_ini = 862.571 uV, v_off_fin = 855.769 uV 18:48:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.234 uVs 18:48:17 I2X Average and RMS of Measurements VT = -98.365 +- 4.072 uVs I2X = 9.050 +- 0.374 uTm^2 18:48:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:48:22 Integrated Voltage Measurement... 18:48:31 Voltage Offset Correction: v_off_ini = 847.516 uV, v_off_fin = 839.208 uV 18:48:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.201 uVs 18:48:31 Integrated Voltage Measurement... 18:48:40 Voltage Offset Correction: v_off_ini = 865.603 uV, v_off_fin = 855.296 uV 18:48:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.299 uVs 18:48:40 Integrated Voltage Measurement... 18:48:49 Voltage Offset Correction: v_off_ini = 863.788 uV, v_off_fin = 853.119 uV 18:48:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.134 uVs 18:48:49 Integrated Voltage Measurement... 18:48:58 Voltage Offset Correction: v_off_ini = 865.117 uV, v_off_fin = 863.629 uV 18:48:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.848 uVs 18:48:58 Integrated Voltage Measurement... 18:49:07 Voltage Offset Correction: v_off_ini = 861.835 uV, v_off_fin = 863.175 uV 18:49:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.490 uVs 18:49:07 Integrated Voltage Measurement... 18:49:16 Voltage Offset Correction: v_off_ini = 862.680 uV, v_off_fin = 864.572 uV 18:49:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.663 uVs 18:49:18 I2Y Average and RMS of Measurements VT = -208.606 +- 6.865 uVs I2Y = -19.192 +- 0.632 uTm^2 18:49:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:49:27 Integrated Voltage Measurement... 18:49:36 Voltage Offset Correction: v_off_ini = 840.533 uV, v_off_fin = 842.821 uV 18:49:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -99.202 uVs 18:49:36 Integrated Voltage Measurement... 18:49:45 Voltage Offset Correction: v_off_ini = 860.433 uV, v_off_fin = 858.660 uV 18:49:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.553 uVs 18:49:45 Integrated Voltage Measurement... 18:49:54 Voltage Offset Correction: v_off_ini = 852.637 uV, v_off_fin = 840.856 uV 18:49:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.079 uVs 18:49:54 Integrated Voltage Measurement... 18:50:03 Voltage Offset Correction: v_off_ini = 860.581 uV, v_off_fin = 867.569 uV 18:50:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.762 uVs 18:50:03 Integrated Voltage Measurement... 18:50:12 Voltage Offset Correction: v_off_ini = 853.713 uV, v_off_fin = 867.575 uV 18:50:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.034 uVs 18:50:12 Integrated Voltage Measurement... 18:50:21 Voltage Offset Correction: v_off_ini = 879.237 uV, v_off_fin = 876.123 uV 18:50:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.487 uVs 18:50:25 I1X Average and RMS of Measurements VT = -92.186 +- 11.090 uVs I1X = 18.438 +- 2.218 uTm 18:50:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:50:32 Integrated Voltage Measurement... 18:50:41 Voltage Offset Correction: v_off_ini = 862.367 uV, v_off_fin = 855.835 uV 18:50:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -174.236 uVs 18:50:41 Integrated Voltage Measurement... 18:50:50 Voltage Offset Correction: v_off_ini = 857.738 uV, v_off_fin = 877.898 uV 18:50:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.770 uVs 18:50:50 Integrated Voltage Measurement... 18:50:59 Voltage Offset Correction: v_off_ini = 860.968 uV, v_off_fin = 849.602 uV 18:50:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.512 uVs 18:50:59 Integrated Voltage Measurement... 18:51:08 Voltage Offset Correction: v_off_ini = 855.306 uV, v_off_fin = 866.369 uV 18:51:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.441 uVs 18:51:08 Integrated Voltage Measurement... 18:51:17 Voltage Offset Correction: v_off_ini = 855.438 uV, v_off_fin = 850.962 uV 18:51:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.283 uVs 18:51:17 Integrated Voltage Measurement... 18:51:26 Voltage Offset Correction: v_off_ini = 867.188 uV, v_off_fin = 868.454 uV 18:51:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.603 uVs 18:51:30 I1Y Average and RMS of Measurements VT = -170.307 +- 1.634 uVs I1Y = -34.063 +- 0.326 uTm 18:51:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:51:35 Integrated Voltage Measurement... 18:51:44 Voltage Offset Correction: v_off_ini = 838.548 uV, v_off_fin = 841.698 uV 18:51:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.356 uVs 18:51:44 Integrated Voltage Measurement... 18:51:53 Voltage Offset Correction: v_off_ini = 849.604 uV, v_off_fin = 866.819 uV 18:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.885 uVs 18:51:53 Integrated Voltage Measurement... 18:52:02 Voltage Offset Correction: v_off_ini = 864.989 uV, v_off_fin = 856.100 uV 18:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.314 uVs 18:52:02 Integrated Voltage Measurement... 18:52:11 Voltage Offset Correction: v_off_ini = 884.015 uV, v_off_fin = 875.995 uV 18:52:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.232 uVs 18:52:12 Integrated Voltage Measurement... 18:52:21 Voltage Offset Correction: v_off_ini = 847.980 uV, v_off_fin = 849.460 uV 18:52:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.629 uVs 18:52:21 Integrated Voltage Measurement... 18:52:30 Voltage Offset Correction: v_off_ini = 852.285 uV, v_off_fin = 869.108 uV 18:52:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.458 uVs 18:52:32 I2X Average and RMS of Measurements VT = -80.979 +- 5.344 uVs I2X = 7.450 +- 0.492 uTm^2 18:52:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:52:37 Integrated Voltage Measurement... 18:52:46 Voltage Offset Correction: v_off_ini = 856.773 uV, v_off_fin = 874.493 uV 18:52:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.708 uVs 18:52:46 Integrated Voltage Measurement... 18:52:55 Voltage Offset Correction: v_off_ini = 887.272 uV, v_off_fin = 865.277 uV 18:52:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.231 uVs 18:52:55 Integrated Voltage Measurement... 18:53:04 Voltage Offset Correction: v_off_ini = 877.527 uV, v_off_fin = 877.920 uV 18:53:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.227 uVs 18:53:04 Integrated Voltage Measurement... 18:53:13 Voltage Offset Correction: v_off_ini = 874.897 uV, v_off_fin = 865.828 uV 18:53:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.649 uVs 18:53:13 Integrated Voltage Measurement... 18:53:22 Voltage Offset Correction: v_off_ini = 878.056 uV, v_off_fin = 876.441 uV 18:53:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.610 uVs 18:53:22 Integrated Voltage Measurement... 18:53:31 Voltage Offset Correction: v_off_ini = 867.173 uV, v_off_fin = 873.984 uV 18:53:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.437 uVs 18:53:34 I2Y Average and RMS of Measurements VT = -208.477 +- 3.735 uVs I2Y = -19.180 +- 0.344 uTm^2 18:53:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:53:42 Integrated Voltage Measurement... 18:53:51 Voltage Offset Correction: v_off_ini = 863.042 uV, v_off_fin = 859.651 uV 18:53:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -90.117 uVs 18:53:51 Integrated Voltage Measurement... 18:54:00 Voltage Offset Correction: v_off_ini = 875.382 uV, v_off_fin = 861.019 uV 18:54:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.618 uVs 18:54:00 Integrated Voltage Measurement... 18:54:09 Voltage Offset Correction: v_off_ini = 855.959 uV, v_off_fin = 860.898 uV 18:54:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.154 uVs 18:54:09 Integrated Voltage Measurement... 18:54:18 Voltage Offset Correction: v_off_ini = 847.289 uV, v_off_fin = 854.332 uV 18:54:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.848 uVs 18:54:18 Integrated Voltage Measurement... 18:54:27 Voltage Offset Correction: v_off_ini = 863.382 uV, v_off_fin = 858.232 uV 18:54:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.213 uVs 18:54:27 Integrated Voltage Measurement... 18:54:36 Voltage Offset Correction: v_off_ini = 861.066 uV, v_off_fin = 881.148 uV 18:54:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.214 uVs 18:54:40 I1X Average and RMS of Measurements VT = -94.027 +- 9.400 uVs I1X = 18.806 +- 1.880 uTm 18:54:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:54:47 Integrated Voltage Measurement... 18:54:56 Voltage Offset Correction: v_off_ini = 848.376 uV, v_off_fin = 841.760 uV 18:54:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.116 uVs 18:54:56 Integrated Voltage Measurement... 18:55:05 Voltage Offset Correction: v_off_ini = 852.118 uV, v_off_fin = 868.382 uV 18:55:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 188.111 uVs 18:55:05 Integrated Voltage Measurement... 18:55:14 Voltage Offset Correction: v_off_ini = 868.166 uV, v_off_fin = 866.561 uV 18:55:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.741 uVs 18:55:14 Integrated Voltage Measurement... 18:55:23 Voltage Offset Correction: v_off_ini = 864.166 uV, v_off_fin = 878.686 uV 18:55:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.025 uVs 18:55:23 Integrated Voltage Measurement... 18:55:32 Voltage Offset Correction: v_off_ini = 851.686 uV, v_off_fin = 858.369 uV 18:55:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -163.987 uVs 18:55:32 Integrated Voltage Measurement... 18:55:41 Voltage Offset Correction: v_off_ini = 859.227 uV, v_off_fin = 865.960 uV 18:55:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 159.425 uVs 18:55:45 I1Y Average and RMS of Measurements VT = -171.901 +- 9.008 uVs I1Y = -34.378 +- 1.801 uTm 18:55:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:55:51 Integrated Voltage Measurement... 18:56:00 Voltage Offset Correction: v_off_ini = 856.826 uV, v_off_fin = 859.974 uV 18:56:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.394 uVs 18:56:00 Integrated Voltage Measurement... 18:56:09 Voltage Offset Correction: v_off_ini = 861.264 uV, v_off_fin = 857.538 uV 18:56:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.764 uVs 18:56:09 Integrated Voltage Measurement... 18:56:18 Voltage Offset Correction: v_off_ini = 859.926 uV, v_off_fin = 843.348 uV 18:56:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.386 uVs 18:56:18 Integrated Voltage Measurement... 18:56:27 Voltage Offset Correction: v_off_ini = 845.662 uV, v_off_fin = 855.606 uV 18:56:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.026 uVs 18:56:27 Integrated Voltage Measurement... 18:56:36 Voltage Offset Correction: v_off_ini = 854.241 uV, v_off_fin = 861.848 uV 18:56:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.538 uVs 18:56:36 Integrated Voltage Measurement... 18:56:45 Voltage Offset Correction: v_off_ini = 876.551 uV, v_off_fin = 863.555 uV 18:56:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.862 uVs 18:56:47 I2X Average and RMS of Measurements VT = -67.995 +- 4.039 uVs I2X = 6.256 +- 0.372 uTm^2 18:56:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:56:52 Integrated Voltage Measurement... 18:57:01 Voltage Offset Correction: v_off_ini = 863.456 uV, v_off_fin = 872.611 uV 18:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.442 uVs 18:57:01 Integrated Voltage Measurement... 18:57:10 Voltage Offset Correction: v_off_ini = 870.129 uV, v_off_fin = 869.956 uV 18:57:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.824 uVs 18:57:10 Integrated Voltage Measurement... 18:57:19 Voltage Offset Correction: v_off_ini = 865.539 uV, v_off_fin = 859.237 uV 18:57:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.279 uVs 18:57:19 Integrated Voltage Measurement... 18:57:28 Voltage Offset Correction: v_off_ini = 878.656 uV, v_off_fin = 874.596 uV 18:57:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.248 uVs 18:57:29 Integrated Voltage Measurement... 18:57:38 Voltage Offset Correction: v_off_ini = 863.568 uV, v_off_fin = 868.821 uV 18:57:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.741 uVs 18:57:38 Integrated Voltage Measurement... 18:57:47 Voltage Offset Correction: v_off_ini = 867.186 uV, v_off_fin = 874.384 uV 18:57:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.576 uVs 18:57:49 I2Y Average and RMS of Measurements VT = -206.852 +- 5.179 uVs I2Y = -19.030 +- 0.476 uTm^2 18:57:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:57:57 Integrated Voltage Measurement... 18:58:06 Voltage Offset Correction: v_off_ini = 862.041 uV, v_off_fin = 865.885 uV 18:58:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.261 uVs 18:58:06 Integrated Voltage Measurement... 18:58:15 Voltage Offset Correction: v_off_ini = 855.214 uV, v_off_fin = 855.723 uV 18:58:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.107 uVs 18:58:15 Integrated Voltage Measurement... 18:58:24 Voltage Offset Correction: v_off_ini = 876.613 uV, v_off_fin = 876.584 uV 18:58:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.467 uVs 18:58:24 Integrated Voltage Measurement... 18:58:33 Voltage Offset Correction: v_off_ini = 877.242 uV, v_off_fin = 864.999 uV 18:58:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.437 uVs 18:58:33 Integrated Voltage Measurement... 18:58:42 Voltage Offset Correction: v_off_ini = 864.836 uV, v_off_fin = 847.743 uV 18:58:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.611 uVs 18:58:42 Integrated Voltage Measurement... 18:58:51 Voltage Offset Correction: v_off_ini = 854.737 uV, v_off_fin = 857.350 uV 18:58:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.317 uVs 18:58:56 I1X Average and RMS of Measurements VT = -85.867 +- 4.382 uVs I1X = 17.174 +- 0.876 uTm 18:58:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:59:02 Integrated Voltage Measurement... 18:59:11 Voltage Offset Correction: v_off_ini = 854.449 uV, v_off_fin = 844.313 uV 18:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -164.915 uVs 18:59:11 Integrated Voltage Measurement... 18:59:20 Voltage Offset Correction: v_off_ini = 845.480 uV, v_off_fin = 859.265 uV 18:59:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.273 uVs 18:59:20 Integrated Voltage Measurement... 18:59:29 Voltage Offset Correction: v_off_ini = 854.717 uV, v_off_fin = 844.731 uV 18:59:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -156.463 uVs 18:59:29 Integrated Voltage Measurement... 18:59:38 Voltage Offset Correction: v_off_ini = 856.032 uV, v_off_fin = 864.072 uV 18:59:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 157.966 uVs 18:59:39 Integrated Voltage Measurement... 18:59:47 Voltage Offset Correction: v_off_ini = 837.843 uV, v_off_fin = 841.638 uV 18:59:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -165.607 uVs 18:59:48 Integrated Voltage Measurement... 18:59:56 Voltage Offset Correction: v_off_ini = 852.171 uV, v_off_fin = 862.944 uV 18:59:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 174.790 uVs 19:00:01 I1Y Average and RMS of Measurements VT = -165.502 +- 5.878 uVs I1Y = -33.098 +- 1.175 uTm 19:00:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:00:06 Integrated Voltage Measurement... 19:00:15 Voltage Offset Correction: v_off_ini = 840.821 uV, v_off_fin = 850.650 uV 19:00:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.282 uVs 19:00:15 Integrated Voltage Measurement... 19:00:24 Voltage Offset Correction: v_off_ini = 870.286 uV, v_off_fin = 856.920 uV 19:00:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.660 uVs 19:00:24 Integrated Voltage Measurement... 19:00:33 Voltage Offset Correction: v_off_ini = 845.169 uV, v_off_fin = 844.826 uV 19:00:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.197 uVs 19:00:33 Integrated Voltage Measurement... 19:00:42 Voltage Offset Correction: v_off_ini = 837.631 uV, v_off_fin = 840.356 uV 19:00:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 59.686 uVs 19:00:42 Integrated Voltage Measurement... 19:00:51 Voltage Offset Correction: v_off_ini = 838.696 uV, v_off_fin = 834.608 uV 19:00:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -53.299 uVs 19:00:51 Integrated Voltage Measurement... 19:01:00 Voltage Offset Correction: v_off_ini = 840.831 uV, v_off_fin = 852.292 uV 19:01:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 62.596 uVs 19:01:02 I2X Average and RMS of Measurements VT = -54.953 +- 4.588 uVs I2X = 5.056 +- 0.422 uTm^2 19:01:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:01:08 Integrated Voltage Measurement... 19:01:17 Voltage Offset Correction: v_off_ini = 861.513 uV, v_off_fin = 852.449 uV 19:01:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.099 uVs 19:01:17 Integrated Voltage Measurement... 19:01:26 Voltage Offset Correction: v_off_ini = 853.604 uV, v_off_fin = 845.802 uV 19:01:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.252 uVs 19:01:26 Integrated Voltage Measurement... 19:01:35 Voltage Offset Correction: v_off_ini = 840.254 uV, v_off_fin = 851.649 uV 19:01:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.447 uVs 19:01:35 Integrated Voltage Measurement... 19:01:44 Voltage Offset Correction: v_off_ini = 848.433 uV, v_off_fin = 855.328 uV 19:01:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.238 uVs 19:01:44 Integrated Voltage Measurement... 19:01:53 Voltage Offset Correction: v_off_ini = 842.730 uV, v_off_fin = 840.719 uV 19:01:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.832 uVs 19:01:53 Integrated Voltage Measurement... 19:02:02 Voltage Offset Correction: v_off_ini = 832.991 uV, v_off_fin = 835.148 uV 19:02:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.613 uVs 19:02:04 I2Y Average and RMS of Measurements VT = -204.747 +- 4.308 uVs I2Y = -18.837 +- 0.396 uTm^2 19:02:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:02:26 Integrated Voltage Measurement... 19:02:34 Voltage Offset Correction: v_off_ini = 850.895 uV, v_off_fin = 855.409 uV 19:02:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.424 uVs 19:02:35 Integrated Voltage Measurement... 19:02:44 Voltage Offset Correction: v_off_ini = 869.141 uV, v_off_fin = 879.832 uV 19:02:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.194 uVs 19:02:44 Integrated Voltage Measurement... 19:02:53 Voltage Offset Correction: v_off_ini = 873.773 uV, v_off_fin = 852.307 uV 19:02:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.560 uVs 19:02:53 Integrated Voltage Measurement... 19:03:02 Voltage Offset Correction: v_off_ini = 863.797 uV, v_off_fin = 860.113 uV 19:03:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.233 uVs 19:03:02 Integrated Voltage Measurement... 19:03:11 Voltage Offset Correction: v_off_ini = 869.448 uV, v_off_fin = 846.986 uV 19:03:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.920 uVs 19:03:11 Integrated Voltage Measurement... 19:03:20 Voltage Offset Correction: v_off_ini = 851.241 uV, v_off_fin = 860.854 uV 19:03:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.405 uVs 19:03:24 I1X Average and RMS of Measurements VT = -95.623 +- 4.635 uVs I1X = 19.125 +- 0.927 uTm 19:03:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:03:31 Integrated Voltage Measurement... 19:03:40 Voltage Offset Correction: v_off_ini = 860.684 uV, v_off_fin = 858.487 uV 19:03:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -155.995 uVs 19:03:40 Integrated Voltage Measurement... 19:03:49 Voltage Offset Correction: v_off_ini = 850.755 uV, v_off_fin = 860.362 uV 19:03:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.140 uVs 19:03:49 Integrated Voltage Measurement... 19:03:58 Voltage Offset Correction: v_off_ini = 843.405 uV, v_off_fin = 840.707 uV 19:03:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -143.575 uVs 19:03:58 Integrated Voltage Measurement... 19:04:07 Voltage Offset Correction: v_off_ini = 841.012 uV, v_off_fin = 863.733 uV 19:04:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.546 uVs 19:04:07 Integrated Voltage Measurement... 19:04:16 Voltage Offset Correction: v_off_ini = 847.794 uV, v_off_fin = 849.449 uV 19:04:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -144.500 uVs 19:04:16 Integrated Voltage Measurement... 19:04:25 Voltage Offset Correction: v_off_ini = 856.069 uV, v_off_fin = 871.693 uV 19:04:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.825 uVs 19:04:29 I1Y Average and RMS of Measurements VT = -153.930 +- 5.065 uVs I1Y = -30.787 +- 1.014 uTm 19:04:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:04:37 Integrated Voltage Measurement... 19:04:46 Voltage Offset Correction: v_off_ini = 852.538 uV, v_off_fin = 855.773 uV 19:04:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.165 uVs 19:04:46 Integrated Voltage Measurement... 19:04:55 Voltage Offset Correction: v_off_ini = 860.345 uV, v_off_fin = 866.689 uV 19:04:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.428 uVs 19:04:55 Integrated Voltage Measurement... 19:05:04 Voltage Offset Correction: v_off_ini = 869.660 uV, v_off_fin = 857.091 uV 19:05:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.455 uVs 19:05:04 Integrated Voltage Measurement... 19:05:13 Voltage Offset Correction: v_off_ini = 864.157 uV, v_off_fin = 872.010 uV 19:05:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.836 uVs 19:05:13 Integrated Voltage Measurement... 19:05:22 Voltage Offset Correction: v_off_ini = 849.375 uV, v_off_fin = 839.557 uV 19:05:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.161 uVs 19:05:22 Integrated Voltage Measurement... 19:05:31 Voltage Offset Correction: v_off_ini = 864.500 uV, v_off_fin = 852.398 uV 19:05:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.764 uVs 19:05:33 I2X Average and RMS of Measurements VT = -76.635 +- 6.147 uVs I2X = 7.050 +- 0.566 uTm^2 19:05:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:05:41 Integrated Voltage Measurement... 19:05:50 Voltage Offset Correction: v_off_ini = 854.298 uV, v_off_fin = 852.934 uV 19:05:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.766 uVs 19:05:50 Integrated Voltage Measurement... 19:05:59 Voltage Offset Correction: v_off_ini = 866.924 uV, v_off_fin = 849.113 uV 19:05:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.749 uVs 19:05:59 Integrated Voltage Measurement... 19:06:08 Voltage Offset Correction: v_off_ini = 853.448 uV, v_off_fin = 846.227 uV 19:06:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.081 uVs 19:06:08 Integrated Voltage Measurement... 19:06:17 Voltage Offset Correction: v_off_ini = 854.570 uV, v_off_fin = 852.543 uV 19:06:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.927 uVs 19:06:17 Integrated Voltage Measurement... 19:06:26 Voltage Offset Correction: v_off_ini = 841.347 uV, v_off_fin = 853.649 uV 19:06:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.326 uVs 19:06:26 Integrated Voltage Measurement... 19:06:35 Voltage Offset Correction: v_off_ini = 867.737 uV, v_off_fin = 862.095 uV 19:06:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.812 uVs 19:06:38 I2Y Average and RMS of Measurements VT = -184.277 +- 7.855 uVs I2Y = -16.953 +- 0.723 uTm^2 19:06:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:06:47 Integrated Voltage Measurement... 19:06:56 Voltage Offset Correction: v_off_ini = 870.853 uV, v_off_fin = 867.346 uV 19:06:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.489 uVs 19:06:56 Integrated Voltage Measurement... 19:07:05 Voltage Offset Correction: v_off_ini = 870.266 uV, v_off_fin = 866.928 uV 19:07:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.158 uVs 19:07:05 Integrated Voltage Measurement... 19:07:14 Voltage Offset Correction: v_off_ini = 860.039 uV, v_off_fin = 859.323 uV 19:07:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.091 uVs 19:07:14 Integrated Voltage Measurement... 19:07:23 Voltage Offset Correction: v_off_ini = 855.307 uV, v_off_fin = 857.183 uV 19:07:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.641 uVs 19:07:23 Integrated Voltage Measurement... 19:07:32 Voltage Offset Correction: v_off_ini = 877.688 uV, v_off_fin = 880.468 uV 19:07:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.509 uVs 19:07:32 Integrated Voltage Measurement... 19:07:41 Voltage Offset Correction: v_off_ini = 884.692 uV, v_off_fin = 863.786 uV 19:07:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.871 uVs 19:07:45 I1X Average and RMS of Measurements VT = -102.627 +- 1.507 uVs I1X = 20.525 +- 0.301 uTm 19:07:48 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:07:52 Integrated Voltage Measurement... 19:08:01 Voltage Offset Correction: v_off_ini = 865.343 uV, v_off_fin = 872.939 uV 19:08:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.551 uVs 19:08:01 Integrated Voltage Measurement... 19:08:10 Voltage Offset Correction: v_off_ini = 878.630 uV, v_off_fin = 879.811 uV 19:08:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.105 uVs 19:08:10 Integrated Voltage Measurement... 19:08:19 Voltage Offset Correction: v_off_ini = 886.898 uV, v_off_fin = 878.319 uV 19:08:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.434 uVs 19:08:19 Integrated Voltage Measurement... 19:08:28 Voltage Offset Correction: v_off_ini = 884.878 uV, v_off_fin = 889.948 uV 19:08:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.558 uVs 19:08:28 Integrated Voltage Measurement... 19:08:37 Voltage Offset Correction: v_off_ini = 879.978 uV, v_off_fin = 855.640 uV 19:08:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.442 uVs 19:08:37 Integrated Voltage Measurement... 19:08:46 Voltage Offset Correction: v_off_ini = 873.048 uV, v_off_fin = 879.844 uV 19:08:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.983 uVs 19:08:50 I1Y Average and RMS of Measurements VT = -170.179 +- 5.206 uVs I1Y = -34.036 +- 1.041 uTm 19:08:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:08:58 Integrated Voltage Measurement... 19:09:07 Voltage Offset Correction: v_off_ini = 869.793 uV, v_off_fin = 853.668 uV 19:09:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.026 uVs 19:09:07 Integrated Voltage Measurement... 19:09:16 Voltage Offset Correction: v_off_ini = 883.703 uV, v_off_fin = 894.804 uV 19:09:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.235 uVs 19:09:16 Integrated Voltage Measurement... 19:09:25 Voltage Offset Correction: v_off_ini = 879.559 uV, v_off_fin = 872.876 uV 19:09:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.079 uVs 19:09:25 Integrated Voltage Measurement... 19:09:34 Voltage Offset Correction: v_off_ini = 877.005 uV, v_off_fin = 865.605 uV 19:09:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.726 uVs 19:09:34 Integrated Voltage Measurement... 19:09:43 Voltage Offset Correction: v_off_ini = 877.233 uV, v_off_fin = 861.610 uV 19:09:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.599 uVs 19:09:43 Integrated Voltage Measurement... 19:09:52 Voltage Offset Correction: v_off_ini = 869.317 uV, v_off_fin = 878.469 uV 19:09:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.624 uVs 19:09:54 I2X Average and RMS of Measurements VT = -78.548 +- 4.517 uVs I2X = 7.227 +- 0.416 uTm^2 19:09:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:10:02 Integrated Voltage Measurement... 19:10:11 Voltage Offset Correction: v_off_ini = 863.136 uV, v_off_fin = 872.002 uV 19:10:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.310 uVs 19:10:11 Integrated Voltage Measurement... 19:10:20 Voltage Offset Correction: v_off_ini = 887.354 uV, v_off_fin = 880.753 uV 19:10:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.811 uVs 19:10:20 Integrated Voltage Measurement... 19:10:29 Voltage Offset Correction: v_off_ini = 868.992 uV, v_off_fin = 868.087 uV 19:10:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.472 uVs 19:10:29 Integrated Voltage Measurement... 19:10:38 Voltage Offset Correction: v_off_ini = 853.179 uV, v_off_fin = 857.977 uV 19:10:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.397 uVs 19:10:38 Integrated Voltage Measurement... 19:10:47 Voltage Offset Correction: v_off_ini = 856.692 uV, v_off_fin = 848.275 uV 19:10:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.385 uVs 19:10:47 Integrated Voltage Measurement... 19:10:56 Voltage Offset Correction: v_off_ini = 861.618 uV, v_off_fin = 845.076 uV 19:10:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.449 uVs 19:10:59 I2Y Average and RMS of Measurements VT = -199.804 +- 5.744 uVs I2Y = -18.382 +- 0.528 uTm^2 19:11:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:11:08 Integrated Voltage Measurement... 19:11:17 Voltage Offset Correction: v_off_ini = 846.894 uV, v_off_fin = 856.286 uV 19:11:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.109 uVs 19:11:17 Integrated Voltage Measurement... 19:11:26 Voltage Offset Correction: v_off_ini = 860.209 uV, v_off_fin = 859.769 uV 19:11:26 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 86.068 uVs 19:11:26 Integrated Voltage Measurement... 19:11:35 Voltage Offset Correction: v_off_ini = 855.885 uV, v_off_fin = 849.837 uV 19:11:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -78.954 uVs 19:11:35 Integrated Voltage Measurement... 19:11:44 Voltage Offset Correction: v_off_ini = 849.557 uV, v_off_fin = 846.268 uV 19:11:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.155 uVs 19:11:44 Integrated Voltage Measurement... 19:11:53 Voltage Offset Correction: v_off_ini = 848.859 uV, v_off_fin = 850.506 uV 19:11:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.653 uVs 19:11:53 Integrated Voltage Measurement... 19:12:02 Voltage Offset Correction: v_off_ini = 867.615 uV, v_off_fin = 879.813 uV 19:12:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.904 uVs 19:12:06 I1X Average and RMS of Measurements VT = -91.141 +- 4.546 uVs I1X = 18.230 +- 0.909 uTm 19:12:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:12:13 Integrated Voltage Measurement... 19:12:22 Voltage Offset Correction: v_off_ini = 866.723 uV, v_off_fin = 866.970 uV 19:12:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.508 uVs 19:12:22 Integrated Voltage Measurement... 19:12:31 Voltage Offset Correction: v_off_ini = 874.252 uV, v_off_fin = 883.755 uV 19:12:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 155.021 uVs 19:12:31 Integrated Voltage Measurement... 19:12:40 Voltage Offset Correction: v_off_ini = 871.920 uV, v_off_fin = 869.199 uV 19:12:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.624 uVs 19:12:40 Integrated Voltage Measurement... 19:12:49 Voltage Offset Correction: v_off_ini = 874.782 uV, v_off_fin = 886.546 uV 19:12:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.146 uVs 19:12:49 Integrated Voltage Measurement... 19:12:58 Voltage Offset Correction: v_off_ini = 868.957 uV, v_off_fin = 859.385 uV 19:12:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.424 uVs 19:12:58 Integrated Voltage Measurement... 19:13:07 Voltage Offset Correction: v_off_ini = 852.651 uV, v_off_fin = 872.180 uV 19:13:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.808 uVs 19:13:11 I1Y Average and RMS of Measurements VT = -167.922 +- 3.628 uVs I1Y = -33.584 +- 0.726 uTm 19:13:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:13:19 Integrated Voltage Measurement... 19:13:28 Voltage Offset Correction: v_off_ini = 857.446 uV, v_off_fin = 859.303 uV 19:13:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.829 uVs 19:13:28 Integrated Voltage Measurement... 19:13:37 Voltage Offset Correction: v_off_ini = 872.481 uV, v_off_fin = 876.869 uV 19:13:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.651 uVs 19:13:37 Integrated Voltage Measurement... 19:13:46 Voltage Offset Correction: v_off_ini = 863.451 uV, v_off_fin = 846.775 uV 19:13:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.604 uVs 19:13:46 Integrated Voltage Measurement... 19:13:55 Voltage Offset Correction: v_off_ini = 868.466 uV, v_off_fin = 870.264 uV 19:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.310 uVs 19:13:55 Integrated Voltage Measurement... 19:14:04 Voltage Offset Correction: v_off_ini = 868.792 uV, v_off_fin = 859.031 uV 19:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.698 uVs 19:14:04 Integrated Voltage Measurement... 19:14:13 Voltage Offset Correction: v_off_ini = 874.225 uV, v_off_fin = 880.421 uV 19:14:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.575 uVs 19:14:15 I2X Average and RMS of Measurements VT = -63.611 +- 7.691 uVs I2X = 5.852 +- 0.708 uTm^2 19:14:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:14:23 Integrated Voltage Measurement... 19:14:32 Voltage Offset Correction: v_off_ini = 867.461 uV, v_off_fin = 858.610 uV 19:14:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.329 uVs 19:14:32 Integrated Voltage Measurement... 19:14:41 Voltage Offset Correction: v_off_ini = 877.705 uV, v_off_fin = 870.930 uV 19:14:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.594 uVs 19:14:41 Integrated Voltage Measurement... 19:14:50 Voltage Offset Correction: v_off_ini = 864.442 uV, v_off_fin = 855.414 uV 19:14:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.960 uVs 19:14:50 Integrated Voltage Measurement... 19:14:59 Voltage Offset Correction: v_off_ini = 852.034 uV, v_off_fin = 874.353 uV 19:14:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.389 uVs 19:14:59 Integrated Voltage Measurement... 19:15:08 Voltage Offset Correction: v_off_ini = 858.845 uV, v_off_fin = 865.251 uV 19:15:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.723 uVs 19:15:08 Integrated Voltage Measurement... 19:15:17 Voltage Offset Correction: v_off_ini = 874.415 uV, v_off_fin = 864.251 uV 19:15:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.431 uVs 19:15:20 I2Y Average and RMS of Measurements VT = -210.071 +- 10.342 uVs I2Y = -19.327 +- 0.951 uTm^2 19:15:24 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:15:29 Integrated Voltage Measurement... 19:15:38 Voltage Offset Correction: v_off_ini = 873.387 uV, v_off_fin = 877.597 uV 19:15:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.168 uVs 19:15:38 Integrated Voltage Measurement... 19:15:47 Voltage Offset Correction: v_off_ini = 868.454 uV, v_off_fin = 886.156 uV 19:15:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.184 uVs 19:15:47 Integrated Voltage Measurement... 19:15:56 Voltage Offset Correction: v_off_ini = 873.034 uV, v_off_fin = 880.398 uV 19:15:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.830 uVs 19:15:56 Integrated Voltage Measurement... 19:16:05 Voltage Offset Correction: v_off_ini = 897.716 uV, v_off_fin = 877.357 uV 19:16:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.330 uVs 19:16:05 Integrated Voltage Measurement... 19:16:14 Voltage Offset Correction: v_off_ini = 883.057 uV, v_off_fin = 881.722 uV 19:16:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.332 uVs 19:16:14 Integrated Voltage Measurement... 19:16:23 Voltage Offset Correction: v_off_ini = 885.181 uV, v_off_fin = 889.760 uV 19:16:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.478 uVs 19:16:27 I1X Average and RMS of Measurements VT = -86.554 +- 3.291 uVs I1X = 17.311 +- 0.658 uTm 19:16:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:16:34 Integrated Voltage Measurement... 19:16:43 Voltage Offset Correction: v_off_ini = 875.501 uV, v_off_fin = 865.167 uV 19:16:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -187.045 uVs 19:16:43 Integrated Voltage Measurement... 19:16:52 Voltage Offset Correction: v_off_ini = 870.491 uV, v_off_fin = 868.882 uV 19:16:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.931 uVs 19:16:52 Integrated Voltage Measurement... 19:17:01 Voltage Offset Correction: v_off_ini = 867.075 uV, v_off_fin = 854.166 uV 19:17:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.081 uVs 19:17:01 Integrated Voltage Measurement... 19:17:10 Voltage Offset Correction: v_off_ini = 868.705 uV, v_off_fin = 873.939 uV 19:17:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.430 uVs 19:17:10 Integrated Voltage Measurement... 19:17:19 Voltage Offset Correction: v_off_ini = 876.250 uV, v_off_fin = 861.346 uV 19:17:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.133 uVs 19:17:19 Integrated Voltage Measurement... 19:17:28 Voltage Offset Correction: v_off_ini = 866.101 uV, v_off_fin = 881.333 uV 19:17:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.726 uVs 19:17:32 I1Y Average and RMS of Measurements VT = -182.891 +- 2.450 uVs I1Y = -36.579 +- 0.490 uTm 19:17:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:17:40 Integrated Voltage Measurement... 19:17:49 Voltage Offset Correction: v_off_ini = 868.754 uV, v_off_fin = 864.253 uV 19:17:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.592 uVs 19:17:49 Integrated Voltage Measurement... 19:17:58 Voltage Offset Correction: v_off_ini = 879.418 uV, v_off_fin = 880.155 uV 19:17:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.437 uVs 19:17:58 Integrated Voltage Measurement... 19:18:07 Voltage Offset Correction: v_off_ini = 876.667 uV, v_off_fin = 870.490 uV 19:18:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.644 uVs 19:18:07 Integrated Voltage Measurement... 19:18:16 Voltage Offset Correction: v_off_ini = 875.551 uV, v_off_fin = 880.447 uV 19:18:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.529 uVs 19:18:16 Integrated Voltage Measurement... 19:18:25 Voltage Offset Correction: v_off_ini = 871.861 uV, v_off_fin = 868.977 uV 19:18:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.763 uVs 19:18:25 Integrated Voltage Measurement... 19:18:34 Voltage Offset Correction: v_off_ini = 883.975 uV, v_off_fin = 881.310 uV 19:18:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.722 uVs 19:18:36 I2X Average and RMS of Measurements VT = -71.114 +- 8.122 uVs I2X = 6.543 +- 0.747 uTm^2 19:18:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:18:44 Integrated Voltage Measurement... 19:18:53 Voltage Offset Correction: v_off_ini = 862.672 uV, v_off_fin = 886.523 uV 19:18:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.389 uVs 19:18:53 Integrated Voltage Measurement... 19:19:02 Voltage Offset Correction: v_off_ini = 879.180 uV, v_off_fin = 868.067 uV 19:19:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.952 uVs 19:19:02 Integrated Voltage Measurement... 19:19:11 Voltage Offset Correction: v_off_ini = 869.155 uV, v_off_fin = 865.735 uV 19:19:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.356 uVs 19:19:11 Integrated Voltage Measurement... 19:19:20 Voltage Offset Correction: v_off_ini = 866.214 uV, v_off_fin = 873.660 uV 19:19:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.954 uVs 19:19:20 Integrated Voltage Measurement... 19:19:29 Voltage Offset Correction: v_off_ini = 872.215 uV, v_off_fin = 877.644 uV 19:19:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.475 uVs 19:19:29 Integrated Voltage Measurement... 19:19:38 Voltage Offset Correction: v_off_ini = 865.697 uV, v_off_fin = 868.745 uV 19:19:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.363 uVs 19:19:41 I2Y Average and RMS of Measurements VT = -206.582 +- 3.612 uVs I2Y = -19.006 +- 0.332 uTm^2 19:19:45 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:19:50 Integrated Voltage Measurement... 19:19:59 Voltage Offset Correction: v_off_ini = 860.663 uV, v_off_fin = 863.626 uV 19:19:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -93.157 uVs 19:19:59 Integrated Voltage Measurement... 19:20:08 Voltage Offset Correction: v_off_ini = 868.994 uV, v_off_fin = 859.985 uV 19:20:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.271 uVs 19:20:08 Integrated Voltage Measurement... 19:20:17 Voltage Offset Correction: v_off_ini = 870.351 uV, v_off_fin = 863.542 uV 19:20:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.930 uVs 19:20:17 Integrated Voltage Measurement... 19:20:26 Voltage Offset Correction: v_off_ini = 877.361 uV, v_off_fin = 874.602 uV 19:20:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.294 uVs 19:20:26 Integrated Voltage Measurement... 19:20:35 Voltage Offset Correction: v_off_ini = 883.102 uV, v_off_fin = 875.862 uV 19:20:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.394 uVs 19:20:35 Integrated Voltage Measurement... 19:20:44 Voltage Offset Correction: v_off_ini = 886.037 uV, v_off_fin = 878.132 uV 19:20:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.751 uVs 19:20:48 I1X Average and RMS of Measurements VT = -93.966 +- 1.897 uVs I1X = 18.794 +- 0.379 uTm 19:20:51 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:20:55 Integrated Voltage Measurement... 19:21:04 Voltage Offset Correction: v_off_ini = 876.476 uV, v_off_fin = 866.017 uV 19:21:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.200 uVs 19:21:04 Integrated Voltage Measurement... 19:21:13 Voltage Offset Correction: v_off_ini = 878.840 uV, v_off_fin = 886.274 uV 19:21:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.714 uVs 19:21:13 Integrated Voltage Measurement... 19:21:22 Voltage Offset Correction: v_off_ini = 871.876 uV, v_off_fin = 872.892 uV 19:21:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.145 uVs 19:21:22 Integrated Voltage Measurement... 19:21:31 Voltage Offset Correction: v_off_ini = 893.008 uV, v_off_fin = 899.659 uV 19:21:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.781 uVs 19:21:31 Integrated Voltage Measurement... 19:21:40 Voltage Offset Correction: v_off_ini = 885.029 uV, v_off_fin = 870.374 uV 19:21:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.056 uVs 19:21:40 Integrated Voltage Measurement... 19:21:49 Voltage Offset Correction: v_off_ini = 878.709 uV, v_off_fin = 895.904 uV 19:21:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.812 uVs 19:21:53 I1Y Average and RMS of Measurements VT = -176.285 +- 2.612 uVs I1Y = -35.257 +- 0.522 uTm 19:21:58 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:22:01 Integrated Voltage Measurement... 19:22:10 Voltage Offset Correction: v_off_ini = 882.576 uV, v_off_fin = 867.389 uV 19:22:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.894 uVs 19:22:10 Integrated Voltage Measurement... 19:22:19 Voltage Offset Correction: v_off_ini = 894.479 uV, v_off_fin = 891.337 uV 19:22:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.197 uVs 19:22:19 Integrated Voltage Measurement... 19:22:28 Voltage Offset Correction: v_off_ini = 896.492 uV, v_off_fin = 892.520 uV 19:22:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.791 uVs 19:22:28 Integrated Voltage Measurement... 19:22:37 Voltage Offset Correction: v_off_ini = 889.353 uV, v_off_fin = 892.361 uV 19:22:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.454 uVs 19:22:37 Integrated Voltage Measurement... 19:22:46 Voltage Offset Correction: v_off_ini = 879.494 uV, v_off_fin = 886.192 uV 19:22:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.416 uVs 19:22:46 Integrated Voltage Measurement... 19:22:55 Voltage Offset Correction: v_off_ini = 882.781 uV, v_off_fin = 904.155 uV 19:22:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.864 uVs 19:22:57 I2X Average and RMS of Measurements VT = -68.769 +- 6.719 uVs I2X = 6.327 +- 0.618 uTm^2 19:23:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:23:05 Integrated Voltage Measurement... 19:23:14 Voltage Offset Correction: v_off_ini = 888.483 uV, v_off_fin = 867.513 uV 19:23:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.820 uVs 19:23:14 Integrated Voltage Measurement... 19:23:23 Voltage Offset Correction: v_off_ini = 866.314 uV, v_off_fin = 865.843 uV 19:23:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.080 uVs 19:23:23 Integrated Voltage Measurement... 19:23:32 Voltage Offset Correction: v_off_ini = 879.448 uV, v_off_fin = 885.719 uV 19:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.038 uVs 19:23:32 Integrated Voltage Measurement... 19:23:41 Voltage Offset Correction: v_off_ini = 873.780 uV, v_off_fin = 879.977 uV 19:23:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.963 uVs 19:23:41 Integrated Voltage Measurement... 19:23:50 Voltage Offset Correction: v_off_ini = 880.579 uV, v_off_fin = 877.739 uV 19:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.172 uVs 19:23:50 Integrated Voltage Measurement... 19:23:59 Voltage Offset Correction: v_off_ini = 880.410 uV, v_off_fin = 884.362 uV 19:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.848 uVs 19:24:02 I2Y Average and RMS of Measurements VT = -216.154 +- 5.165 uVs I2Y = -19.886 +- 0.475 uTm^2 19:24:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:24:14 Integrated Voltage Measurement... 19:24:23 Voltage Offset Correction: v_off_ini = 884.034 uV, v_off_fin = 881.328 uV 19:24:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -109.372 uVs 19:24:23 Integrated Voltage Measurement... 19:24:32 Voltage Offset Correction: v_off_ini = 881.966 uV, v_off_fin = 887.371 uV 19:24:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.827 uVs 19:24:32 Integrated Voltage Measurement... 19:24:41 Voltage Offset Correction: v_off_ini = 889.162 uV, v_off_fin = 871.590 uV 19:24:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.010 uVs 19:24:41 Integrated Voltage Measurement... 19:24:50 Voltage Offset Correction: v_off_ini = 878.049 uV, v_off_fin = 879.731 uV 19:24:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.628 uVs 19:24:50 Integrated Voltage Measurement... 19:24:59 Voltage Offset Correction: v_off_ini = 879.930 uV, v_off_fin = 866.538 uV 19:24:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.209 uVs 19:24:59 Integrated Voltage Measurement... 19:25:08 Voltage Offset Correction: v_off_ini = 886.406 uV, v_off_fin = 880.263 uV 19:25:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.885 uVs 19:25:12 I1X Average and RMS of Measurements VT = -102.655 +- 7.638 uVs I1X = 20.531 +- 1.528 uTm 19:25:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:25:19 Integrated Voltage Measurement... 19:25:28 Voltage Offset Correction: v_off_ini = 872.580 uV, v_off_fin = 871.619 uV 19:25:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.748 uVs 19:25:28 Integrated Voltage Measurement... 19:25:37 Voltage Offset Correction: v_off_ini = 873.624 uV, v_off_fin = 880.370 uV 19:25:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.257 uVs 19:25:37 Integrated Voltage Measurement... 19:25:46 Voltage Offset Correction: v_off_ini = 888.740 uV, v_off_fin = 872.295 uV 19:25:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.855 uVs 19:25:46 Integrated Voltage Measurement... 19:25:55 Voltage Offset Correction: v_off_ini = 879.156 uV, v_off_fin = 887.575 uV 19:25:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.365 uVs 19:25:55 Integrated Voltage Measurement... 19:26:04 Voltage Offset Correction: v_off_ini = 878.863 uV, v_off_fin = 881.657 uV 19:26:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.437 uVs 19:26:04 Integrated Voltage Measurement... 19:26:13 Voltage Offset Correction: v_off_ini = 882.208 uV, v_off_fin = 890.869 uV 19:26:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.346 uVs 19:26:17 I1Y Average and RMS of Measurements VT = -173.001 +- 6.851 uVs I1Y = -34.600 +- 1.370 uTm 19:26:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:26:22 Integrated Voltage Measurement... 19:26:31 Voltage Offset Correction: v_off_ini = 861.623 uV, v_off_fin = 866.466 uV 19:26:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.280 uVs 19:26:31 Integrated Voltage Measurement... 19:26:40 Voltage Offset Correction: v_off_ini = 875.555 uV, v_off_fin = 871.679 uV 19:26:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.680 uVs 19:26:40 Integrated Voltage Measurement... 19:26:49 Voltage Offset Correction: v_off_ini = 858.274 uV, v_off_fin = 855.202 uV 19:26:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.022 uVs 19:26:49 Integrated Voltage Measurement... 19:26:58 Voltage Offset Correction: v_off_ini = 875.441 uV, v_off_fin = 879.409 uV 19:26:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.626 uVs 19:26:58 Integrated Voltage Measurement... 19:27:07 Voltage Offset Correction: v_off_ini = 885.535 uV, v_off_fin = 878.891 uV 19:27:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.021 uVs 19:27:08 Integrated Voltage Measurement... 19:27:17 Voltage Offset Correction: v_off_ini = 893.573 uV, v_off_fin = 887.710 uV 19:27:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.912 uVs 19:27:19 I2X Average and RMS of Measurements VT = -79.924 +- 3.487 uVs I2X = 7.353 +- 0.321 uTm^2 19:27:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:27:24 Integrated Voltage Measurement... 19:27:33 Voltage Offset Correction: v_off_ini = 887.306 uV, v_off_fin = 893.788 uV 19:27:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.120 uVs 19:27:33 Integrated Voltage Measurement... 19:27:42 Voltage Offset Correction: v_off_ini = 887.464 uV, v_off_fin = 879.783 uV 19:27:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.876 uVs 19:27:42 Integrated Voltage Measurement... 19:27:51 Voltage Offset Correction: v_off_ini = 876.103 uV, v_off_fin = 879.933 uV 19:27:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.833 uVs 19:27:51 Integrated Voltage Measurement... 19:28:00 Voltage Offset Correction: v_off_ini = 886.349 uV, v_off_fin = 869.920 uV 19:28:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.820 uVs 19:28:00 Integrated Voltage Measurement... 19:28:09 Voltage Offset Correction: v_off_ini = 890.761 uV, v_off_fin = 886.279 uV 19:28:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.826 uVs 19:28:09 Integrated Voltage Measurement... 19:28:18 Voltage Offset Correction: v_off_ini = 884.540 uV, v_off_fin = 889.456 uV 19:28:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.670 uVs 19:28:21 I2Y Average and RMS of Measurements VT = -206.524 +- 6.911 uVs I2Y = -19.000 +- 0.636 uTm^2 19:28:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:28:29 Integrated Voltage Measurement... 19:28:38 Voltage Offset Correction: v_off_ini = 893.297 uV, v_off_fin = 894.403 uV 19:28:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.768 uVs 19:28:38 Integrated Voltage Measurement... 19:28:47 Voltage Offset Correction: v_off_ini = 892.354 uV, v_off_fin = 888.381 uV 19:28:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.854 uVs 19:28:47 Integrated Voltage Measurement... 19:28:56 Voltage Offset Correction: v_off_ini = 881.126 uV, v_off_fin = 883.784 uV 19:28:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.742 uVs 19:28:56 Integrated Voltage Measurement... 19:29:05 Voltage Offset Correction: v_off_ini = 877.363 uV, v_off_fin = 880.417 uV 19:29:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 111.498 uVs 19:29:05 Integrated Voltage Measurement... 19:29:14 Voltage Offset Correction: v_off_ini = 892.187 uV, v_off_fin = 873.818 uV 19:29:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -101.783 uVs 19:29:14 Integrated Voltage Measurement... 19:29:23 Voltage Offset Correction: v_off_ini = 881.017 uV, v_off_fin = 884.623 uV 19:29:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.479 uVs 19:29:27 I1X Average and RMS of Measurements VT = -105.521 +- 5.348 uVs I1X = 21.105 +- 1.069 uTm 19:29:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:29:34 Integrated Voltage Measurement... 19:29:43 Voltage Offset Correction: v_off_ini = 870.093 uV, v_off_fin = 857.346 uV 19:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -163.389 uVs 19:29:43 Integrated Voltage Measurement... 19:29:52 Voltage Offset Correction: v_off_ini = 881.161 uV, v_off_fin = 883.068 uV 19:29:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.520 uVs 19:29:52 Integrated Voltage Measurement... 19:30:01 Voltage Offset Correction: v_off_ini = 871.854 uV, v_off_fin = 860.314 uV 19:30:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.642 uVs 19:30:01 Integrated Voltage Measurement... 19:30:10 Voltage Offset Correction: v_off_ini = 866.298 uV, v_off_fin = 868.463 uV 19:30:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.466 uVs 19:30:10 Integrated Voltage Measurement... 19:30:19 Voltage Offset Correction: v_off_ini = 855.878 uV, v_off_fin = 866.290 uV 19:30:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.745 uVs 19:30:19 Integrated Voltage Measurement... 19:30:28 Voltage Offset Correction: v_off_ini = 851.050 uV, v_off_fin = 864.755 uV 19:30:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.464 uVs 19:30:32 I1Y Average and RMS of Measurements VT = -170.538 +- 2.063 uVs I1Y = -34.109 +- 0.413 uTm 19:30:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:30:38 Integrated Voltage Measurement... 19:30:46 Voltage Offset Correction: v_off_ini = 855.327 uV, v_off_fin = 854.670 uV 19:30:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.140 uVs 19:30:47 Integrated Voltage Measurement... 19:30:56 Voltage Offset Correction: v_off_ini = 858.201 uV, v_off_fin = 861.862 uV 19:30:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.667 uVs 19:30:56 Integrated Voltage Measurement... 19:31:05 Voltage Offset Correction: v_off_ini = 856.275 uV, v_off_fin = 847.920 uV 19:31:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.582 uVs 19:31:05 Integrated Voltage Measurement... 19:31:14 Voltage Offset Correction: v_off_ini = 868.393 uV, v_off_fin = 876.349 uV 19:31:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.577 uVs 19:31:14 Integrated Voltage Measurement... 19:31:23 Voltage Offset Correction: v_off_ini = 877.847 uV, v_off_fin = 872.267 uV 19:31:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.391 uVs 19:31:23 Integrated Voltage Measurement... 19:31:32 Voltage Offset Correction: v_off_ini = 887.640 uV, v_off_fin = 887.206 uV 19:31:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.055 uVs 19:31:34 I2X Average and RMS of Measurements VT = -73.402 +- 9.700 uVs I2X = 6.753 +- 0.892 uTm^2 19:31:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:31:39 Integrated Voltage Measurement... 19:31:48 Voltage Offset Correction: v_off_ini = 890.129 uV, v_off_fin = 880.831 uV 19:31:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.912 uVs 19:31:48 Integrated Voltage Measurement... 19:31:57 Voltage Offset Correction: v_off_ini = 871.239 uV, v_off_fin = 868.397 uV 19:31:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.653 uVs 19:31:57 Integrated Voltage Measurement... 19:32:06 Voltage Offset Correction: v_off_ini = 863.623 uV, v_off_fin = 866.661 uV 19:32:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.091 uVs 19:32:06 Integrated Voltage Measurement... 19:32:15 Voltage Offset Correction: v_off_ini = 886.509 uV, v_off_fin = 896.083 uV 19:32:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.503 uVs 19:32:15 Integrated Voltage Measurement... 19:32:24 Voltage Offset Correction: v_off_ini = 896.563 uV, v_off_fin = 893.915 uV 19:32:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.625 uVs 19:32:25 Integrated Voltage Measurement... 19:32:34 Voltage Offset Correction: v_off_ini = 881.073 uV, v_off_fin = 875.059 uV 19:32:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.048 uVs 19:32:36 I2Y Average and RMS of Measurements VT = -210.639 +- 9.625 uVs I2Y = -19.379 +- 0.886 uTm^2 19:32:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:32:44 Integrated Voltage Measurement... 19:32:53 Voltage Offset Correction: v_off_ini = 870.320 uV, v_off_fin = 871.542 uV 19:32:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.045 uVs 19:32:53 Integrated Voltage Measurement... 19:33:02 Voltage Offset Correction: v_off_ini = 867.402 uV, v_off_fin = 863.180 uV 19:33:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.506 uVs 19:33:02 Integrated Voltage Measurement... 19:33:11 Voltage Offset Correction: v_off_ini = 863.374 uV, v_off_fin = 857.111 uV 19:33:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -95.069 uVs 19:33:11 Integrated Voltage Measurement... 19:33:20 Voltage Offset Correction: v_off_ini = 863.204 uV, v_off_fin = 869.960 uV 19:33:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 97.385 uVs 19:33:20 Integrated Voltage Measurement... 19:33:29 Voltage Offset Correction: v_off_ini = 846.010 uV, v_off_fin = 843.887 uV 19:33:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.203 uVs 19:33:29 Integrated Voltage Measurement... 19:33:38 Voltage Offset Correction: v_off_ini = 853.013 uV, v_off_fin = 851.296 uV 19:33:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.527 uVs 19:33:43 I1X Average and RMS of Measurements VT = -98.622 +- 1.897 uVs I1X = 19.726 +- 0.378 uTm 19:33:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:33:49 Integrated Voltage Measurement... 19:33:58 Voltage Offset Correction: v_off_ini = 867.306 uV, v_off_fin = 857.978 uV 19:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.976 uVs 19:33:58 Integrated Voltage Measurement... 19:34:07 Voltage Offset Correction: v_off_ini = 854.613 uV, v_off_fin = 865.059 uV 19:34:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.579 uVs 19:34:07 Integrated Voltage Measurement... 19:34:16 Voltage Offset Correction: v_off_ini = 878.993 uV, v_off_fin = 869.573 uV 19:34:16 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.961 uVs 19:34:16 Integrated Voltage Measurement... 19:34:25 Voltage Offset Correction: v_off_ini = 868.028 uV, v_off_fin = 877.805 uV 19:34:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.790 uVs 19:34:25 Integrated Voltage Measurement... 19:34:34 Voltage Offset Correction: v_off_ini = 863.475 uV, v_off_fin = 851.861 uV 19:34:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.352 uVs 19:34:34 Integrated Voltage Measurement... 19:34:43 Voltage Offset Correction: v_off_ini = 844.823 uV, v_off_fin = 849.521 uV 19:34:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.145 uVs 19:34:48 I1Y Average and RMS of Measurements VT = -167.967 +- 5.686 uVs I1Y = -33.594 +- 1.138 uTm 19:34:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:34:53 Integrated Voltage Measurement... 19:35:02 Voltage Offset Correction: v_off_ini = 839.390 uV, v_off_fin = 843.101 uV 19:35:02 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -64.884 uVs 19:35:02 Integrated Voltage Measurement... 19:35:11 Voltage Offset Correction: v_off_ini = 859.624 uV, v_off_fin = 844.821 uV 19:35:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 75.213 uVs 19:35:11 Integrated Voltage Measurement... 19:35:20 Voltage Offset Correction: v_off_ini = 843.613 uV, v_off_fin = 844.857 uV 19:35:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.640 uVs 19:35:20 Integrated Voltage Measurement... 19:35:29 Voltage Offset Correction: v_off_ini = 861.624 uV, v_off_fin = 855.637 uV 19:35:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.728 uVs 19:35:29 Integrated Voltage Measurement... 19:35:38 Voltage Offset Correction: v_off_ini = 860.926 uV, v_off_fin = 850.113 uV 19:35:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.338 uVs 19:35:38 Integrated Voltage Measurement... 19:35:47 Voltage Offset Correction: v_off_ini = 858.491 uV, v_off_fin = 864.834 uV 19:35:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.617 uVs 19:35:49 I2X Average and RMS of Measurements VT = -66.570 +- 2.888 uVs I2X = 6.124 +- 0.266 uTm^2 19:35:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:35:55 Integrated Voltage Measurement... 19:36:04 Voltage Offset Correction: v_off_ini = 851.940 uV, v_off_fin = 848.926 uV 19:36:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.976 uVs 19:36:04 Integrated Voltage Measurement... 19:36:13 Voltage Offset Correction: v_off_ini = 846.161 uV, v_off_fin = 852.756 uV 19:36:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.430 uVs 19:36:13 Integrated Voltage Measurement... 19:36:22 Voltage Offset Correction: v_off_ini = 853.853 uV, v_off_fin = 856.728 uV 19:36:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.511 uVs 19:36:22 Integrated Voltage Measurement... 19:36:31 Voltage Offset Correction: v_off_ini = 843.197 uV, v_off_fin = 849.919 uV 19:36:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.698 uVs 19:36:31 Integrated Voltage Measurement... 19:36:40 Voltage Offset Correction: v_off_ini = 842.363 uV, v_off_fin = 839.926 uV 19:36:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.524 uVs 19:36:40 Integrated Voltage Measurement... 19:36:49 Voltage Offset Correction: v_off_ini = 857.160 uV, v_off_fin = 860.146 uV 19:36:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.236 uVs 19:36:51 I2Y Average and RMS of Measurements VT = -199.729 +- 8.052 uVs I2Y = -18.375 +- 0.741 uTm^2 19:36:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:37:00 Integrated Voltage Measurement... 19:37:09 Voltage Offset Correction: v_off_ini = 861.942 uV, v_off_fin = 854.242 uV 19:37:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.358 uVs 19:37:09 Integrated Voltage Measurement... 19:37:18 Voltage Offset Correction: v_off_ini = 848.966 uV, v_off_fin = 848.658 uV 19:37:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.632 uVs 19:37:18 Integrated Voltage Measurement... 19:37:27 Voltage Offset Correction: v_off_ini = 854.256 uV, v_off_fin = 855.454 uV 19:37:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.813 uVs 19:37:27 Integrated Voltage Measurement... 19:37:36 Voltage Offset Correction: v_off_ini = 854.206 uV, v_off_fin = 849.233 uV 19:37:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.333 uVs 19:37:36 Integrated Voltage Measurement... 19:37:45 Voltage Offset Correction: v_off_ini = 846.449 uV, v_off_fin = 859.256 uV 19:37:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.823 uVs 19:37:45 Integrated Voltage Measurement... 19:37:54 Voltage Offset Correction: v_off_ini = 866.191 uV, v_off_fin = 850.738 uV 19:37:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.353 uVs 19:37:58 I1X Average and RMS of Measurements VT = -94.052 +- 7.449 uVs I1X = 18.811 +- 1.490 uTm 19:38:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:38:05 Integrated Voltage Measurement... 19:38:14 Voltage Offset Correction: v_off_ini = 867.688 uV, v_off_fin = 861.509 uV 19:38:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -146.921 uVs 19:38:14 Integrated Voltage Measurement... 19:38:23 Voltage Offset Correction: v_off_ini = 866.961 uV, v_off_fin = 881.690 uV 19:38:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.601 uVs 19:38:23 Integrated Voltage Measurement... 19:38:32 Voltage Offset Correction: v_off_ini = 873.943 uV, v_off_fin = 867.507 uV 19:38:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -158.326 uVs 19:38:32 Integrated Voltage Measurement... 19:38:41 Voltage Offset Correction: v_off_ini = 866.162 uV, v_off_fin = 872.472 uV 19:38:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.013 uVs 19:38:41 Integrated Voltage Measurement... 19:38:50 Voltage Offset Correction: v_off_ini = 865.083 uV, v_off_fin = 863.323 uV 19:38:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.713 uVs 19:38:50 Integrated Voltage Measurement... 19:38:59 Voltage Offset Correction: v_off_ini = 870.450 uV, v_off_fin = 876.315 uV 19:38:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.272 uVs 19:39:03 I1Y Average and RMS of Measurements VT = -168.474 +- 4.474 uVs I1Y = -33.695 +- 0.895 uTm 19:39:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:39:08 Integrated Voltage Measurement... 19:39:17 Voltage Offset Correction: v_off_ini = 865.338 uV, v_off_fin = 858.251 uV 19:39:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.511 uVs 19:39:17 Integrated Voltage Measurement... 19:39:26 Voltage Offset Correction: v_off_ini = 860.494 uV, v_off_fin = 881.801 uV 19:39:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.810 uVs 19:39:26 Integrated Voltage Measurement... 19:39:35 Voltage Offset Correction: v_off_ini = 866.435 uV, v_off_fin = 859.136 uV 19:39:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.058 uVs 19:39:35 Integrated Voltage Measurement... 19:39:44 Voltage Offset Correction: v_off_ini = 848.246 uV, v_off_fin = 861.356 uV 19:39:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.961 uVs 19:39:44 Integrated Voltage Measurement... 19:39:53 Voltage Offset Correction: v_off_ini = 858.241 uV, v_off_fin = 829.199 uV 19:39:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.072 uVs 19:39:53 Integrated Voltage Measurement... 19:40:02 Voltage Offset Correction: v_off_ini = 841.580 uV, v_off_fin = 850.590 uV 19:40:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.856 uVs 19:40:05 I2X Average and RMS of Measurements VT = -67.878 +- 1.351 uVs I2X = 6.245 +- 0.124 uTm^2 19:40:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:40:10 Integrated Voltage Measurement... 19:40:19 Voltage Offset Correction: v_off_ini = 856.940 uV, v_off_fin = 850.310 uV 19:40:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.203 uVs 19:40:19 Integrated Voltage Measurement... 19:40:28 Voltage Offset Correction: v_off_ini = 843.430 uV, v_off_fin = 847.243 uV 19:40:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.273 uVs 19:40:28 Integrated Voltage Measurement... 19:40:37 Voltage Offset Correction: v_off_ini = 866.922 uV, v_off_fin = 849.083 uV 19:40:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.006 uVs 19:40:37 Integrated Voltage Measurement... 19:40:46 Voltage Offset Correction: v_off_ini = 862.600 uV, v_off_fin = 876.258 uV 19:40:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.952 uVs 19:40:46 Integrated Voltage Measurement... 19:40:55 Voltage Offset Correction: v_off_ini = 871.247 uV, v_off_fin = 875.019 uV 19:40:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.689 uVs 19:40:55 Integrated Voltage Measurement... 19:41:04 Voltage Offset Correction: v_off_ini = 865.711 uV, v_off_fin = 861.840 uV 19:41:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.622 uVs 19:41:07 I2Y Average and RMS of Measurements VT = -202.291 +- 5.493 uVs I2Y = -18.611 +- 0.505 uTm^2 19:41:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:41:15 Integrated Voltage Measurement... 19:41:24 Voltage Offset Correction: v_off_ini = 867.179 uV, v_off_fin = 870.521 uV 19:41:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -78.523 uVs 19:41:24 Integrated Voltage Measurement... 19:41:33 Voltage Offset Correction: v_off_ini = 866.167 uV, v_off_fin = 868.286 uV 19:41:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.096 uVs 19:41:33 Integrated Voltage Measurement... 19:41:42 Voltage Offset Correction: v_off_ini = 852.703 uV, v_off_fin = 863.751 uV 19:41:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.695 uVs 19:41:42 Integrated Voltage Measurement... 19:41:51 Voltage Offset Correction: v_off_ini = 867.489 uV, v_off_fin = 862.444 uV 19:41:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.948 uVs 19:41:51 Integrated Voltage Measurement... 19:42:00 Voltage Offset Correction: v_off_ini = 864.134 uV, v_off_fin = 856.961 uV 19:42:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.110 uVs 19:42:00 Integrated Voltage Measurement... 19:42:09 Voltage Offset Correction: v_off_ini = 863.800 uV, v_off_fin = 874.280 uV 19:42:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 76.862 uVs 19:42:13 I1X Average and RMS of Measurements VT = -79.372 +- 10.823 uVs I1X = 15.876 +- 2.165 uTm 19:42:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:42:20 Integrated Voltage Measurement... 19:42:29 Voltage Offset Correction: v_off_ini = 860.103 uV, v_off_fin = 858.130 uV 19:42:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -164.078 uVs 19:42:29 Integrated Voltage Measurement... 19:42:38 Voltage Offset Correction: v_off_ini = 863.278 uV, v_off_fin = 878.058 uV 19:42:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 179.603 uVs 19:42:38 Integrated Voltage Measurement... 19:42:47 Voltage Offset Correction: v_off_ini = 859.083 uV, v_off_fin = 855.327 uV 19:42:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -150.895 uVs 19:42:47 Integrated Voltage Measurement... 19:42:56 Voltage Offset Correction: v_off_ini = 874.415 uV, v_off_fin = 886.456 uV 19:42:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.876 uVs 19:42:56 Integrated Voltage Measurement... 19:43:05 Voltage Offset Correction: v_off_ini = 855.885 uV, v_off_fin = 857.250 uV 19:43:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.281 uVs 19:43:05 Integrated Voltage Measurement... 19:43:14 Voltage Offset Correction: v_off_ini = 863.243 uV, v_off_fin = 877.283 uV 19:43:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.100 uVs 19:43:18 I1Y Average and RMS of Measurements VT = -161.805 +- 7.112 uVs I1Y = -32.362 +- 1.424 uTm 19:43:21 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:43:23 Integrated Voltage Measurement... 19:43:32 Voltage Offset Correction: v_off_ini = 864.447 uV, v_off_fin = 853.563 uV 19:43:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.811 uVs 19:43:32 Integrated Voltage Measurement... 19:43:41 Voltage Offset Correction: v_off_ini = 865.149 uV, v_off_fin = 864.628 uV 19:43:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.225 uVs 19:43:41 Integrated Voltage Measurement... 19:43:50 Voltage Offset Correction: v_off_ini = 863.648 uV, v_off_fin = 845.776 uV 19:43:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.624 uVs 19:43:51 Integrated Voltage Measurement... 19:44:00 Voltage Offset Correction: v_off_ini = 850.059 uV, v_off_fin = 869.785 uV 19:44:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.159 uVs 19:44:00 Integrated Voltage Measurement... 19:44:09 Voltage Offset Correction: v_off_ini = 868.655 uV, v_off_fin = 861.573 uV 19:44:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.949 uVs 19:44:09 Integrated Voltage Measurement... 19:44:18 Voltage Offset Correction: v_off_ini = 861.230 uV, v_off_fin = 863.881 uV 19:44:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.467 uVs 19:44:20 I2X Average and RMS of Measurements VT = -65.372 +- 3.254 uVs I2X = 6.014 +- 0.299 uTm^2 19:44:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:44:25 Integrated Voltage Measurement... 19:44:34 Voltage Offset Correction: v_off_ini = 864.415 uV, v_off_fin = 868.599 uV 19:44:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.864 uVs 19:44:34 Integrated Voltage Measurement... 19:44:43 Voltage Offset Correction: v_off_ini = 871.891 uV, v_off_fin = 868.202 uV 19:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.943 uVs 19:44:43 Integrated Voltage Measurement... 19:44:52 Voltage Offset Correction: v_off_ini = 876.148 uV, v_off_fin = 867.542 uV 19:44:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.855 uVs 19:44:52 Integrated Voltage Measurement... 19:45:01 Voltage Offset Correction: v_off_ini = 856.124 uV, v_off_fin = 859.907 uV 19:45:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.508 uVs 19:45:01 Integrated Voltage Measurement... 19:45:10 Voltage Offset Correction: v_off_ini = 855.951 uV, v_off_fin = 888.251 uV 19:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.615 uVs 19:45:10 Integrated Voltage Measurement... 19:45:19 Voltage Offset Correction: v_off_ini = 892.438 uV, v_off_fin = 885.367 uV 19:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.384 uVs 19:45:22 I2Y Average and RMS of Measurements VT = -198.028 +- 12.205 uVs I2Y = -18.219 +- 1.123 uTm^2 19:45:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:45:57 Integrated Voltage Measurement... 19:46:06 Voltage Offset Correction: v_off_ini = 894.900 uV, v_off_fin = 887.024 uV 19:46:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -41.322 uVs 19:46:06 Integrated Voltage Measurement... 19:46:15 Voltage Offset Correction: v_off_ini = 879.835 uV, v_off_fin = 888.155 uV 19:46:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.308 uVs 19:46:15 Integrated Voltage Measurement... 19:46:24 Voltage Offset Correction: v_off_ini = 890.628 uV, v_off_fin = 880.144 uV 19:46:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.842 uVs 19:46:24 Integrated Voltage Measurement... 19:46:33 Voltage Offset Correction: v_off_ini = 870.629 uV, v_off_fin = 885.757 uV 19:46:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.982 uVs 19:46:33 Integrated Voltage Measurement... 19:46:42 Voltage Offset Correction: v_off_ini = 895.133 uV, v_off_fin = 880.098 uV 19:46:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.104 uVs 19:46:42 Integrated Voltage Measurement... 19:46:51 Voltage Offset Correction: v_off_ini = 887.477 uV, v_off_fin = 892.435 uV 19:46:51 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 35.489 uVs 19:46:56 I1X Average and RMS of Measurements VT = -41.508 +- 1.685 uVs I1X = 8.302 +- 0.337 uTm 19:46:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:47:02 Integrated Voltage Measurement... 19:47:11 Voltage Offset Correction: v_off_ini = 886.141 uV, v_off_fin = 888.280 uV 19:47:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.998 uVs 19:47:11 Integrated Voltage Measurement... 19:47:20 Voltage Offset Correction: v_off_ini = 876.547 uV, v_off_fin = 889.533 uV 19:47:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.503 uVs 19:47:20 Integrated Voltage Measurement... 19:47:29 Voltage Offset Correction: v_off_ini = 889.106 uV, v_off_fin = 864.736 uV 19:47:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.763 uVs 19:47:29 Integrated Voltage Measurement... 19:47:38 Voltage Offset Correction: v_off_ini = 880.441 uV, v_off_fin = 883.048 uV 19:47:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.944 uVs 19:47:38 Integrated Voltage Measurement... 19:47:47 Voltage Offset Correction: v_off_ini = 873.398 uV, v_off_fin = 868.681 uV 19:47:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.263 uVs 19:47:47 Integrated Voltage Measurement... 19:47:56 Voltage Offset Correction: v_off_ini = 886.293 uV, v_off_fin = 890.927 uV 19:47:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.346 uVs 19:48:01 I1Y Average and RMS of Measurements VT = -209.469 +- 1.321 uVs I1Y = -41.894 +- 0.264 uTm 19:48:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:48:08 Integrated Voltage Measurement... 19:48:17 Voltage Offset Correction: v_off_ini = 862.978 uV, v_off_fin = 873.466 uV 19:48:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.076 uVs 19:48:17 Integrated Voltage Measurement... 19:48:26 Voltage Offset Correction: v_off_ini = 889.493 uV, v_off_fin = 892.202 uV 19:48:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.804 uVs 19:48:26 Integrated Voltage Measurement... 19:48:35 Voltage Offset Correction: v_off_ini = 882.855 uV, v_off_fin = 885.832 uV 19:48:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.694 uVs 19:48:36 Integrated Voltage Measurement... 19:48:45 Voltage Offset Correction: v_off_ini = 891.498 uV, v_off_fin = 885.444 uV 19:48:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.054 uVs 19:48:45 Integrated Voltage Measurement... 19:48:54 Voltage Offset Correction: v_off_ini = 875.292 uV, v_off_fin = 853.690 uV 19:48:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.518 uVs 19:48:54 Integrated Voltage Measurement... 19:49:03 Voltage Offset Correction: v_off_ini = 860.507 uV, v_off_fin = 870.095 uV 19:49:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.073 uVs 19:49:05 I2X Average and RMS of Measurements VT = -32.536 +- 6.560 uVs I2X = 2.993 +- 0.604 uTm^2 19:49:10 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:49:13 Integrated Voltage Measurement... 19:49:22 Voltage Offset Correction: v_off_ini = 870.413 uV, v_off_fin = 880.986 uV 19:49:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.283 uVs 19:49:22 Integrated Voltage Measurement... 19:49:31 Voltage Offset Correction: v_off_ini = 867.958 uV, v_off_fin = 867.542 uV 19:49:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.301 uVs 19:49:31 Integrated Voltage Measurement... 19:49:40 Voltage Offset Correction: v_off_ini = 873.702 uV, v_off_fin = 864.024 uV 19:49:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.276 uVs 19:49:40 Integrated Voltage Measurement... 19:49:49 Voltage Offset Correction: v_off_ini = 866.877 uV, v_off_fin = 865.309 uV 19:49:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.765 uVs 19:49:49 Integrated Voltage Measurement... 19:49:58 Voltage Offset Correction: v_off_ini = 866.320 uV, v_off_fin = 861.522 uV 19:49:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.978 uVs 19:49:58 Integrated Voltage Measurement... 19:50:07 Voltage Offset Correction: v_off_ini = 870.689 uV, v_off_fin = 877.183 uV 19:50:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.583 uVs 19:50:09 I2Y Average and RMS of Measurements VT = -224.531 +- 5.886 uVs I2Y = -20.657 +- 0.541 uTm^2 19:50:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:50:18 Integrated Voltage Measurement... 19:50:27 Voltage Offset Correction: v_off_ini = 876.917 uV, v_off_fin = 863.345 uV 19:50:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.600 uVs 19:50:27 Integrated Voltage Measurement... 19:50:36 Voltage Offset Correction: v_off_ini = 874.794 uV, v_off_fin = 881.643 uV 19:50:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 47.860 uVs 19:50:36 Integrated Voltage Measurement... 19:50:45 Voltage Offset Correction: v_off_ini = 869.117 uV, v_off_fin = 872.645 uV 19:50:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -38.271 uVs 19:50:45 Integrated Voltage Measurement... 19:50:54 Voltage Offset Correction: v_off_ini = 869.866 uV, v_off_fin = 892.917 uV 19:50:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 44.138 uVs 19:50:54 Integrated Voltage Measurement... 19:51:03 Voltage Offset Correction: v_off_ini = 894.091 uV, v_off_fin = 892.046 uV 19:51:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.803 uVs 19:51:04 Integrated Voltage Measurement... 19:51:12 Voltage Offset Correction: v_off_ini = 882.097 uV, v_off_fin = 886.854 uV 19:51:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.514 uVs 19:51:17 I1X Average and RMS of Measurements VT = -49.698 +- 10.950 uVs I1X = 9.940 +- 2.189 uTm 19:51:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:51:24 Integrated Voltage Measurement... 19:51:32 Voltage Offset Correction: v_off_ini = 858.296 uV, v_off_fin = 875.401 uV 19:51:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.780 uVs 19:51:33 Integrated Voltage Measurement... 19:51:41 Voltage Offset Correction: v_off_ini = 882.041 uV, v_off_fin = 882.926 uV 19:51:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.014 uVs 19:51:42 Integrated Voltage Measurement... 19:51:50 Voltage Offset Correction: v_off_ini = 879.074 uV, v_off_fin = 878.212 uV 19:51:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.305 uVs 19:51:51 Integrated Voltage Measurement... 19:51:59 Voltage Offset Correction: v_off_ini = 883.664 uV, v_off_fin = 879.187 uV 19:52:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.599 uVs 19:52:00 Integrated Voltage Measurement... 19:52:09 Voltage Offset Correction: v_off_ini = 866.169 uV, v_off_fin = 885.713 uV 19:52:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.205 uVs 19:52:09 Integrated Voltage Measurement... 19:52:18 Voltage Offset Correction: v_off_ini = 900.265 uV, v_off_fin = 896.779 uV 19:52:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.551 uVs 19:52:22 I1Y Average and RMS of Measurements VT = -214.576 +- 2.003 uVs I1Y = -42.915 +- 0.401 uTm 19:52:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:52:29 Integrated Voltage Measurement... 19:52:38 Voltage Offset Correction: v_off_ini = 879.780 uV, v_off_fin = 869.278 uV 19:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.147 uVs 19:52:39 Integrated Voltage Measurement... 19:52:48 Voltage Offset Correction: v_off_ini = 864.196 uV, v_off_fin = 886.909 uV 19:52:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.417 uVs 19:52:48 Integrated Voltage Measurement... 19:52:57 Voltage Offset Correction: v_off_ini = 892.835 uV, v_off_fin = 880.953 uV 19:52:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.124 uVs 19:52:57 Integrated Voltage Measurement... 19:53:06 Voltage Offset Correction: v_off_ini = 901.868 uV, v_off_fin = 897.758 uV 19:53:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.758 uVs 19:53:06 Integrated Voltage Measurement... 19:53:15 Voltage Offset Correction: v_off_ini = 893.586 uV, v_off_fin = 873.675 uV 19:53:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.312 uVs 19:53:15 Integrated Voltage Measurement... 19:53:24 Voltage Offset Correction: v_off_ini = 882.941 uV, v_off_fin = 879.008 uV 19:53:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.755 uVs 19:53:26 I2X Average and RMS of Measurements VT = -30.752 +- 5.358 uVs I2X = 2.829 +- 0.493 uTm^2 19:53:31 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:53:34 Integrated Voltage Measurement... 19:53:43 Voltage Offset Correction: v_off_ini = 878.810 uV, v_off_fin = 875.483 uV 19:53:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.893 uVs 19:53:43 Integrated Voltage Measurement... 19:53:52 Voltage Offset Correction: v_off_ini = 880.498 uV, v_off_fin = 884.112 uV 19:53:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.431 uVs 19:53:52 Integrated Voltage Measurement... 19:54:01 Voltage Offset Correction: v_off_ini = 908.276 uV, v_off_fin = 875.169 uV 19:54:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.879 uVs 19:54:01 Integrated Voltage Measurement... 19:54:10 Voltage Offset Correction: v_off_ini = 867.968 uV, v_off_fin = 873.106 uV 19:54:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.200 uVs 19:54:10 Integrated Voltage Measurement... 19:54:19 Voltage Offset Correction: v_off_ini = 884.201 uV, v_off_fin = 882.331 uV 19:54:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.719 uVs 19:54:19 Integrated Voltage Measurement... 19:54:28 Voltage Offset Correction: v_off_ini = 901.908 uV, v_off_fin = 891.269 uV 19:54:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.307 uVs 19:54:31 I2Y Average and RMS of Measurements VT = -228.572 +- 8.436 uVs I2Y = -21.029 +- 0.776 uTm^2 19:54:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:54:39 Integrated Voltage Measurement... 19:54:48 Voltage Offset Correction: v_off_ini = 883.766 uV, v_off_fin = 873.900 uV 19:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -35.852 uVs 19:54:48 Integrated Voltage Measurement... 19:54:57 Voltage Offset Correction: v_off_ini = 882.420 uV, v_off_fin = 880.421 uV 19:54:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.316 uVs 19:54:58 Integrated Voltage Measurement... 19:55:07 Voltage Offset Correction: v_off_ini = 881.168 uV, v_off_fin = 865.950 uV 19:55:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.421 uVs 19:55:07 Integrated Voltage Measurement... 19:55:16 Voltage Offset Correction: v_off_ini = 872.384 uV, v_off_fin = 887.395 uV 19:55:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.393 uVs 19:55:16 Integrated Voltage Measurement... 19:55:25 Voltage Offset Correction: v_off_ini = 870.915 uV, v_off_fin = 873.178 uV 19:55:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.861 uVs 19:55:25 Integrated Voltage Measurement... 19:55:34 Voltage Offset Correction: v_off_ini = 869.674 uV, v_off_fin = 880.204 uV 19:55:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.675 uVs 19:55:38 I1X Average and RMS of Measurements VT = -47.920 +- 4.149 uVs I1X = 9.584 +- 0.830 uTm 19:55:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:55:45 Integrated Voltage Measurement... 19:55:54 Voltage Offset Correction: v_off_ini = 877.469 uV, v_off_fin = 867.433 uV 19:55:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.587 uVs 19:55:54 Integrated Voltage Measurement... 19:56:03 Voltage Offset Correction: v_off_ini = 865.856 uV, v_off_fin = 871.091 uV 19:56:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.773 uVs 19:56:03 Integrated Voltage Measurement... 19:56:12 Voltage Offset Correction: v_off_ini = 861.189 uV, v_off_fin = 853.162 uV 19:56:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.963 uVs 19:56:12 Integrated Voltage Measurement... 19:56:21 Voltage Offset Correction: v_off_ini = 865.704 uV, v_off_fin = 874.264 uV 19:56:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.508 uVs 19:56:21 Integrated Voltage Measurement... 19:56:30 Voltage Offset Correction: v_off_ini = 875.675 uV, v_off_fin = 849.373 uV 19:56:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.144 uVs 19:56:30 Integrated Voltage Measurement... 19:56:39 Voltage Offset Correction: v_off_ini = 869.018 uV, v_off_fin = 874.648 uV 19:56:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.645 uVs 19:56:43 I1Y Average and RMS of Measurements VT = -215.603 +- 3.792 uVs I1Y = -43.121 +- 0.758 uTm 19:56:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:56:51 Integrated Voltage Measurement... 19:57:00 Voltage Offset Correction: v_off_ini = 859.438 uV, v_off_fin = 867.595 uV 19:57:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.742 uVs 19:57:00 Integrated Voltage Measurement... 19:57:09 Voltage Offset Correction: v_off_ini = 876.937 uV, v_off_fin = 880.586 uV 19:57:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.605 uVs 19:57:09 Integrated Voltage Measurement... 19:57:18 Voltage Offset Correction: v_off_ini = 865.833 uV, v_off_fin = 853.608 uV 19:57:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.012 uVs 19:57:18 Integrated Voltage Measurement... 19:57:27 Voltage Offset Correction: v_off_ini = 879.344 uV, v_off_fin = 869.948 uV 19:57:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.037 uVs 19:57:27 Integrated Voltage Measurement... 19:57:36 Voltage Offset Correction: v_off_ini = 872.368 uV, v_off_fin = 870.633 uV 19:57:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.354 uVs 19:57:36 Integrated Voltage Measurement... 19:57:45 Voltage Offset Correction: v_off_ini = 871.316 uV, v_off_fin = 880.671 uV 19:57:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.971 uVs 19:57:47 I2X Average and RMS of Measurements VT = -32.287 +- 4.924 uVs I2X = 2.970 +- 0.453 uTm^2 19:57:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:57:55 Integrated Voltage Measurement... 19:58:04 Voltage Offset Correction: v_off_ini = 862.713 uV, v_off_fin = 856.939 uV 19:58:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.182 uVs 19:58:04 Integrated Voltage Measurement... 19:58:13 Voltage Offset Correction: v_off_ini = 866.563 uV, v_off_fin = 864.995 uV 19:58:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.188 uVs 19:58:13 Integrated Voltage Measurement... 19:58:22 Voltage Offset Correction: v_off_ini = 865.568 uV, v_off_fin = 864.017 uV 19:58:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.636 uVs 19:58:22 Integrated Voltage Measurement... 19:58:31 Voltage Offset Correction: v_off_ini = 859.176 uV, v_off_fin = 859.489 uV 19:58:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.937 uVs 19:58:31 Integrated Voltage Measurement... 19:58:40 Voltage Offset Correction: v_off_ini = 874.173 uV, v_off_fin = 864.693 uV 19:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.924 uVs 19:58:40 Integrated Voltage Measurement... 19:58:49 Voltage Offset Correction: v_off_ini = 869.618 uV, v_off_fin = 850.428 uV 19:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.745 uVs 19:58:52 I2Y Average and RMS of Measurements VT = -227.602 +- 8.332 uVs I2Y = -20.939 +- 0.767 uTm^2 19:58:56 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:59:01 Integrated Voltage Measurement... 19:59:10 Voltage Offset Correction: v_off_ini = 859.861 uV, v_off_fin = 865.124 uV 19:59:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.323 uVs 19:59:10 Integrated Voltage Measurement... 19:59:19 Voltage Offset Correction: v_off_ini = 857.231 uV, v_off_fin = 848.555 uV 19:59:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.027 uVs 19:59:19 Integrated Voltage Measurement... 19:59:28 Voltage Offset Correction: v_off_ini = 845.785 uV, v_off_fin = 850.818 uV 19:59:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.743 uVs 19:59:28 Integrated Voltage Measurement... 19:59:37 Voltage Offset Correction: v_off_ini = 850.293 uV, v_off_fin = 845.625 uV 19:59:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.422 uVs 19:59:37 Integrated Voltage Measurement... 19:59:46 Voltage Offset Correction: v_off_ini = 845.456 uV, v_off_fin = 850.639 uV 19:59:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.819 uVs 19:59:46 Integrated Voltage Measurement... 19:59:55 Voltage Offset Correction: v_off_ini = 854.397 uV, v_off_fin = 848.998 uV 19:59:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.735 uVs 19:59:59 I1X Average and RMS of Measurements VT = -52.178 +- 10.476 uVs I1X = 10.436 +- 2.095 uTm 20:00:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:00:06 Integrated Voltage Measurement... 20:00:15 Voltage Offset Correction: v_off_ini = 843.497 uV, v_off_fin = 839.277 uV 20:00:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.631 uVs 20:00:15 Integrated Voltage Measurement... 20:00:24 Voltage Offset Correction: v_off_ini = 853.237 uV, v_off_fin = 856.463 uV 20:00:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.912 uVs 20:00:24 Integrated Voltage Measurement... 20:00:33 Voltage Offset Correction: v_off_ini = 845.782 uV, v_off_fin = 839.160 uV 20:00:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.991 uVs 20:00:33 Integrated Voltage Measurement... 20:00:42 Voltage Offset Correction: v_off_ini = 847.021 uV, v_off_fin = 858.221 uV 20:00:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.355 uVs 20:00:42 Integrated Voltage Measurement... 20:00:51 Voltage Offset Correction: v_off_ini = 868.080 uV, v_off_fin = 859.001 uV 20:00:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.757 uVs 20:00:51 Integrated Voltage Measurement... 20:01:00 Voltage Offset Correction: v_off_ini = 865.650 uV, v_off_fin = 862.298 uV 20:01:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.801 uVs 20:01:04 I1Y Average and RMS of Measurements VT = -215.408 +- 4.906 uVs I1Y = -43.082 +- 0.981 uTm 20:01:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:01:12 Integrated Voltage Measurement... 20:01:21 Voltage Offset Correction: v_off_ini = 855.181 uV, v_off_fin = 844.021 uV 20:01:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -16.671 uVs 20:01:21 Integrated Voltage Measurement... 20:01:30 Voltage Offset Correction: v_off_ini = 872.799 uV, v_off_fin = 867.502 uV 20:01:30 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 27.807 uVs 20:01:30 Integrated Voltage Measurement... 20:01:39 Voltage Offset Correction: v_off_ini = 862.785 uV, v_off_fin = 850.971 uV 20:01:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.446 uVs 20:01:39 Integrated Voltage Measurement... 20:01:48 Voltage Offset Correction: v_off_ini = 856.391 uV, v_off_fin = 854.923 uV 20:01:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.445 uVs 20:01:48 Integrated Voltage Measurement... 20:01:57 Voltage Offset Correction: v_off_ini = 848.213 uV, v_off_fin = 847.009 uV 20:01:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.830 uVs 20:01:57 Integrated Voltage Measurement... 20:02:06 Voltage Offset Correction: v_off_ini = 856.434 uV, v_off_fin = 873.502 uV 20:02:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 15.842 uVs 20:02:08 I2X Average and RMS of Measurements VT = -22.673 +- 0.476 uVs I2X = 2.086 +- 0.044 uTm^2 20:02:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 20:02:16 Integrated Voltage Measurement... 20:02:25 Voltage Offset Correction: v_off_ini = 840.511 uV, v_off_fin = 848.706 uV 20:02:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.506 uVs 20:02:25 Integrated Voltage Measurement... 20:02:34 Voltage Offset Correction: v_off_ini = 852.636 uV, v_off_fin = 855.929 uV 20:02:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.834 uVs 20:02:34 Integrated Voltage Measurement... 20:02:43 Voltage Offset Correction: v_off_ini = 861.325 uV, v_off_fin = 853.765 uV 20:02:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.835 uVs 20:02:43 Integrated Voltage Measurement... 20:02:52 Voltage Offset Correction: v_off_ini = 849.419 uV, v_off_fin = 836.226 uV 20:02:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.450 uVs 20:02:52 Integrated Voltage Measurement... 20:03:01 Voltage Offset Correction: v_off_ini = 842.716 uV, v_off_fin = 839.847 uV 20:03:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.099 uVs 20:03:01 Integrated Voltage Measurement... 20:03:10 Voltage Offset Correction: v_off_ini = 838.847 uV, v_off_fin = 840.219 uV 20:03:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.614 uVs 20:03:13 I2Y Average and RMS of Measurements VT = -226.890 +- 7.453 uVs I2Y = -20.874 +- 0.686 uTm^2 20:03:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:03:22 Integrated Voltage Measurement... 20:03:31 Voltage Offset Correction: v_off_ini = 830.417 uV, v_off_fin = 837.164 uV 20:03:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.897 uVs 20:03:31 Integrated Voltage Measurement... 20:03:40 Voltage Offset Correction: v_off_ini = 821.906 uV, v_off_fin = 828.155 uV 20:03:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.229 uVs 20:03:40 Integrated Voltage Measurement... 20:03:49 Voltage Offset Correction: v_off_ini = 820.916 uV, v_off_fin = 836.569 uV 20:03:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -51.479 uVs 20:03:49 Integrated Voltage Measurement... 20:03:58 Voltage Offset Correction: v_off_ini = 815.427 uV, v_off_fin = 805.518 uV 20:03:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.756 uVs 20:03:58 Integrated Voltage Measurement... 20:04:07 Voltage Offset Correction: v_off_ini = 820.936 uV, v_off_fin = 818.034 uV 20:04:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.767 uVs 20:04:07 Integrated Voltage Measurement... 20:04:16 Voltage Offset Correction: v_off_ini = 821.272 uV, v_off_fin = 821.081 uV 20:04:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.222 uVs 20:04:20 I1X Average and RMS of Measurements VT = -50.392 +- 2.288 uVs I1X = 10.078 +- 0.458 uTm 20:04:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:04:27 Integrated Voltage Measurement... 20:04:36 Voltage Offset Correction: v_off_ini = 821.290 uV, v_off_fin = 811.567 uV 20:04:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.215 uVs 20:04:36 Integrated Voltage Measurement... 20:04:45 Voltage Offset Correction: v_off_ini = 819.663 uV, v_off_fin = 825.133 uV 20:04:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.140 uVs 20:04:45 Integrated Voltage Measurement... 20:04:54 Voltage Offset Correction: v_off_ini = 822.830 uV, v_off_fin = 816.897 uV 20:04:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.688 uVs 20:04:54 Integrated Voltage Measurement... 20:05:03 Voltage Offset Correction: v_off_ini = 824.911 uV, v_off_fin = 833.277 uV 20:05:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.347 uVs 20:05:03 Integrated Voltage Measurement... 20:05:12 Voltage Offset Correction: v_off_ini = 826.167 uV, v_off_fin = 817.888 uV 20:05:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.205 uVs 20:05:12 Integrated Voltage Measurement... 20:05:21 Voltage Offset Correction: v_off_ini = 839.796 uV, v_off_fin = 835.680 uV 20:05:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.954 uVs 20:05:25 I1Y Average and RMS of Measurements VT = -214.758 +- 3.326 uVs I1Y = -42.952 +- 0.665 uTm 20:05:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:05:33 Integrated Voltage Measurement... 20:05:42 Voltage Offset Correction: v_off_ini = 818.662 uV, v_off_fin = 824.763 uV 20:05:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.150 uVs 20:05:42 Integrated Voltage Measurement... 20:05:51 Voltage Offset Correction: v_off_ini = 843.372 uV, v_off_fin = 836.925 uV 20:05:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.679 uVs 20:05:51 Integrated Voltage Measurement... 20:06:00 Voltage Offset Correction: v_off_ini = 848.902 uV, v_off_fin = 846.144 uV 20:06:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.984 uVs 20:06:00 Integrated Voltage Measurement... 20:06:09 Voltage Offset Correction: v_off_ini = 843.229 uV, v_off_fin = 847.886 uV 20:06:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.009 uVs 20:06:09 Integrated Voltage Measurement... 20:06:18 Voltage Offset Correction: v_off_ini = 832.657 uV, v_off_fin = 834.157 uV 20:06:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.159 uVs 20:06:18 Integrated Voltage Measurement... 20:06:27 Voltage Offset Correction: v_off_ini = 847.902 uV, v_off_fin = 860.432 uV 20:06:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.274 uVs 20:06:29 I2X Average and RMS of Measurements VT = -26.543 +- 9.928 uVs I2X = 2.442 +- 0.913 uTm^2 20:06:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 20:06:37 Integrated Voltage Measurement... 20:06:46 Voltage Offset Correction: v_off_ini = 845.794 uV, v_off_fin = 852.380 uV 20:06:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.837 uVs 20:06:46 Integrated Voltage Measurement... 20:06:55 Voltage Offset Correction: v_off_ini = 837.460 uV, v_off_fin = 843.453 uV 20:06:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.722 uVs 20:06:55 Integrated Voltage Measurement... 20:07:04 Voltage Offset Correction: v_off_ini = 823.306 uV, v_off_fin = 822.043 uV 20:07:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.948 uVs 20:07:04 Integrated Voltage Measurement... 20:07:13 Voltage Offset Correction: v_off_ini = 836.172 uV, v_off_fin = 843.666 uV 20:07:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.742 uVs 20:07:13 Integrated Voltage Measurement... 20:07:22 Voltage Offset Correction: v_off_ini = 845.374 uV, v_off_fin = 838.365 uV 20:07:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.265 uVs 20:07:22 Integrated Voltage Measurement... 20:07:31 Voltage Offset Correction: v_off_ini = 853.112 uV, v_off_fin = 841.796 uV 20:07:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.128 uVs 20:07:34 I2Y Average and RMS of Measurements VT = -222.774 +- 3.932 uVs I2Y = -20.495 +- 0.362 uTm^2 20:07:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:07:46 Integrated Voltage Measurement... 20:07:55 Voltage Offset Correction: v_off_ini = 846.978 uV, v_off_fin = 848.062 uV 20:07:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -33.876 uVs 20:07:55 Integrated Voltage Measurement... 20:08:04 Voltage Offset Correction: v_off_ini = 860.326 uV, v_off_fin = 850.403 uV 20:08:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.311 uVs 20:08:04 Integrated Voltage Measurement... 20:08:13 Voltage Offset Correction: v_off_ini = 846.125 uV, v_off_fin = 848.957 uV 20:08:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.125 uVs 20:08:13 Integrated Voltage Measurement... 20:08:22 Voltage Offset Correction: v_off_ini = 870.850 uV, v_off_fin = 858.769 uV 20:08:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 9.426 uVs 20:08:22 Integrated Voltage Measurement... 20:08:31 Voltage Offset Correction: v_off_ini = 866.465 uV, v_off_fin = 864.657 uV 20:08:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.204 uVs 20:08:31 Integrated Voltage Measurement... 20:08:40 Voltage Offset Correction: v_off_ini = 853.922 uV, v_off_fin = 870.505 uV 20:08:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = 31.537 uVs 20:08:44 I1X Average and RMS of Measurements VT = -39.080 +- 4.554 uVs I1X = 7.816 +- 0.911 uTm 20:08:47 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:08:51 Integrated Voltage Measurement... 20:09:00 Voltage Offset Correction: v_off_ini = 842.443 uV, v_off_fin = 840.465 uV 20:09:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.049 uVs 20:09:00 Integrated Voltage Measurement... 20:09:09 Voltage Offset Correction: v_off_ini = 862.777 uV, v_off_fin = 864.386 uV 20:09:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.417 uVs 20:09:09 Integrated Voltage Measurement... 20:09:18 Voltage Offset Correction: v_off_ini = 847.783 uV, v_off_fin = 838.317 uV 20:09:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.598 uVs 20:09:18 Integrated Voltage Measurement... 20:09:27 Voltage Offset Correction: v_off_ini = 849.412 uV, v_off_fin = 869.340 uV 20:09:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.372 uVs 20:09:27 Integrated Voltage Measurement... 20:09:36 Voltage Offset Correction: v_off_ini = 848.780 uV, v_off_fin = 845.405 uV 20:09:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.492 uVs 20:09:36 Integrated Voltage Measurement... 20:09:45 Voltage Offset Correction: v_off_ini = 853.761 uV, v_off_fin = 841.721 uV 20:09:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.903 uVs 20:09:49 I1Y Average and RMS of Measurements VT = -217.139 +- 1.705 uVs I1Y = -43.428 +- 0.341 uTm 20:09:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:09:54 Integrated Voltage Measurement... 20:10:03 Voltage Offset Correction: v_off_ini = 829.787 uV, v_off_fin = 835.369 uV 20:10:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -2.635 uVs 20:10:03 Integrated Voltage Measurement... 20:10:12 Voltage Offset Correction: v_off_ini = 833.458 uV, v_off_fin = 846.744 uV 20:10:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.378 uVs 20:10:12 Integrated Voltage Measurement... 20:10:21 Voltage Offset Correction: v_off_ini = 848.427 uV, v_off_fin = 852.282 uV 20:10:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.989 uVs 20:10:21 Integrated Voltage Measurement... 20:10:30 Voltage Offset Correction: v_off_ini = 856.875 uV, v_off_fin = 859.136 uV 20:10:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.195 uVs 20:10:30 Integrated Voltage Measurement... 20:10:39 Voltage Offset Correction: v_off_ini = 850.944 uV, v_off_fin = 843.449 uV 20:10:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.916 uVs 20:10:40 Integrated Voltage Measurement... 20:10:49 Voltage Offset Correction: v_off_ini = 837.176 uV, v_off_fin = 831.252 uV 20:10:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.566 uVs 20:10:51 I2X Average and RMS of Measurements VT = -19.280 +- 0.847 uVs I2X = 1.774 +- 0.078 uTm^2 20:10:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 20:10:56 Integrated Voltage Measurement... 20:11:05 Voltage Offset Correction: v_off_ini = 835.215 uV, v_off_fin = 846.121 uV 20:11:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.437 uVs 20:11:05 Integrated Voltage Measurement... 20:11:14 Voltage Offset Correction: v_off_ini = 848.285 uV, v_off_fin = 842.933 uV 20:11:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 217.449 uVs 20:11:14 Integrated Voltage Measurement... 20:11:23 Voltage Offset Correction: v_off_ini = 847.001 uV, v_off_fin = 846.498 uV 20:11:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.382 uVs 20:11:23 Integrated Voltage Measurement... 20:11:32 Voltage Offset Correction: v_off_ini = 853.609 uV, v_off_fin = 848.868 uV 20:11:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.109 uVs 20:11:32 Integrated Voltage Measurement... 20:11:41 Voltage Offset Correction: v_off_ini = 852.604 uV, v_off_fin = 855.769 uV 20:11:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.885 uVs 20:11:41 Integrated Voltage Measurement... 20:11:50 Voltage Offset Correction: v_off_ini = 853.100 uV, v_off_fin = 865.961 uV 20:11:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.374 uVs 20:11:53 I2Y Average and RMS of Measurements VT = -221.606 +- 9.423 uVs I2Y = -20.388 +- 0.867 uTm^2 20:11:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:12:01 Integrated Voltage Measurement... 20:12:10 Voltage Offset Correction: v_off_ini = 854.241 uV, v_off_fin = 856.416 uV 20:12:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -50.324 uVs 20:12:10 Integrated Voltage Measurement... 20:12:19 Voltage Offset Correction: v_off_ini = 868.860 uV, v_off_fin = 869.141 uV 20:12:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.349 uVs 20:12:19 Integrated Voltage Measurement... 20:12:28 Voltage Offset Correction: v_off_ini = 875.576 uV, v_off_fin = 870.663 uV 20:12:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.445 uVs 20:12:28 Integrated Voltage Measurement... 20:12:37 Voltage Offset Correction: v_off_ini = 868.607 uV, v_off_fin = 863.603 uV 20:12:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 45.635 uVs 20:12:37 Integrated Voltage Measurement... 20:12:46 Voltage Offset Correction: v_off_ini = 874.680 uV, v_off_fin = 869.846 uV 20:12:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.624 uVs 20:12:46 Integrated Voltage Measurement... 20:12:55 Voltage Offset Correction: v_off_ini = 862.043 uV, v_off_fin = 869.390 uV 20:12:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.870 uVs 20:12:59 I1X Average and RMS of Measurements VT = -50.207 +- 5.499 uVs I1X = 10.042 +- 1.099 uTm 20:13:02 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:13:06 Integrated Voltage Measurement... 20:13:15 Voltage Offset Correction: v_off_ini = 875.978 uV, v_off_fin = 874.696 uV 20:13:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.737 uVs 20:13:15 Integrated Voltage Measurement... 20:13:24 Voltage Offset Correction: v_off_ini = 879.066 uV, v_off_fin = 885.178 uV 20:13:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.556 uVs 20:13:24 Integrated Voltage Measurement... 20:13:33 Voltage Offset Correction: v_off_ini = 858.645 uV, v_off_fin = 854.889 uV 20:13:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.394 uVs 20:13:33 Integrated Voltage Measurement... 20:13:42 Voltage Offset Correction: v_off_ini = 850.522 uV, v_off_fin = 871.760 uV 20:13:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.840 uVs 20:13:42 Integrated Voltage Measurement... 20:13:51 Voltage Offset Correction: v_off_ini = 854.257 uV, v_off_fin = 847.084 uV 20:13:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.037 uVs 20:13:51 Integrated Voltage Measurement... 20:14:00 Voltage Offset Correction: v_off_ini = 872.597 uV, v_off_fin = 870.073 uV 20:14:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.891 uVs 20:14:04 I1Y Average and RMS of Measurements VT = -207.743 +- 6.666 uVs I1Y = -41.549 +- 1.333 uTm 20:14:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:14:09 Integrated Voltage Measurement... 20:14:18 Voltage Offset Correction: v_off_ini = 853.896 uV, v_off_fin = 858.557 uV 20:14:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -26.793 uVs 20:14:18 Integrated Voltage Measurement... 20:14:27 Voltage Offset Correction: v_off_ini = 868.903 uV, v_off_fin = 870.065 uV 20:14:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.772 uVs 20:14:27 Integrated Voltage Measurement... 20:14:36 Voltage Offset Correction: v_off_ini = 846.916 uV, v_off_fin = 848.804 uV 20:14:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.824 uVs 20:14:36 Integrated Voltage Measurement... 20:14:45 Voltage Offset Correction: v_off_ini = 855.933 uV, v_off_fin = 868.737 uV 20:14:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 23.515 uVs 20:14:45 Integrated Voltage Measurement... 20:14:54 Voltage Offset Correction: v_off_ini = 873.889 uV, v_off_fin = 877.140 uV 20:14:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.249 uVs 20:14:54 Integrated Voltage Measurement... 20:15:03 Voltage Offset Correction: v_off_ini = 879.640 uV, v_off_fin = 893.825 uV 20:15:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.336 uVs 20:15:06 I2X Average and RMS of Measurements VT = -30.081 +- 10.480 uVs I2X = 2.768 +- 0.964 uTm^2 20:15:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 20:15:11 Integrated Voltage Measurement... 20:15:20 Voltage Offset Correction: v_off_ini = 880.511 uV, v_off_fin = 870.841 uV 20:15:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.424 uVs 20:15:20 Integrated Voltage Measurement... 20:15:29 Voltage Offset Correction: v_off_ini = 888.827 uV, v_off_fin = 897.012 uV 20:15:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.478 uVs 20:15:29 Integrated Voltage Measurement... 20:15:38 Voltage Offset Correction: v_off_ini = 880.516 uV, v_off_fin = 881.390 uV 20:15:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.911 uVs 20:15:38 Integrated Voltage Measurement... 20:15:47 Voltage Offset Correction: v_off_ini = 877.329 uV, v_off_fin = 866.896 uV 20:15:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.173 uVs 20:15:47 Integrated Voltage Measurement... 20:15:56 Voltage Offset Correction: v_off_ini = 872.348 uV, v_off_fin = 875.067 uV 20:15:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.042 uVs 20:15:56 Integrated Voltage Measurement... 20:16:05 Voltage Offset Correction: v_off_ini = 884.789 uV, v_off_fin = 871.846 uV 20:16:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.039 uVs 20:16:07 I2Y Average and RMS of Measurements VT = -231.844 +- 5.682 uVs I2Y = -21.330 +- 0.523 uTm^2 20:16:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:16:16 Integrated Voltage Measurement... 20:16:24 Voltage Offset Correction: v_off_ini = 863.888 uV, v_off_fin = 862.918 uV 20:16:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.324 uVs 20:16:25 Integrated Voltage Measurement... 20:16:33 Voltage Offset Correction: v_off_ini = 863.726 uV, v_off_fin = 864.903 uV 20:16:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.841 uVs 20:16:34 Integrated Voltage Measurement... 20:16:42 Voltage Offset Correction: v_off_ini = 854.714 uV, v_off_fin = 844.953 uV 20:16:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.511 uVs 20:16:43 Integrated Voltage Measurement... 20:16:51 Voltage Offset Correction: v_off_ini = 853.680 uV, v_off_fin = 866.656 uV 20:16:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.804 uVs 20:16:52 Integrated Voltage Measurement... 20:17:01 Voltage Offset Correction: v_off_ini = 875.736 uV, v_off_fin = 874.989 uV 20:17:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.304 uVs 20:17:01 Integrated Voltage Measurement... 20:17:10 Voltage Offset Correction: v_off_ini = 865.720 uV, v_off_fin = 861.405 uV 20:17:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.880 uVs 20:17:14 I1X Average and RMS of Measurements VT = -49.277 +- 3.938 uVs I1X = 9.856 +- 0.788 uTm 20:17:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:17:20 Integrated Voltage Measurement... 20:17:29 Voltage Offset Correction: v_off_ini = 858.450 uV, v_off_fin = 857.091 uV 20:17:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.639 uVs 20:17:29 Integrated Voltage Measurement... 20:17:38 Voltage Offset Correction: v_off_ini = 848.107 uV, v_off_fin = 870.390 uV 20:17:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.844 uVs 20:17:38 Integrated Voltage Measurement... 20:17:47 Voltage Offset Correction: v_off_ini = 875.369 uV, v_off_fin = 858.950 uV 20:17:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.948 uVs 20:17:47 Integrated Voltage Measurement... 20:17:56 Voltage Offset Correction: v_off_ini = 855.404 uV, v_off_fin = 872.346 uV 20:17:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.997 uVs 20:17:56 Integrated Voltage Measurement... 20:18:05 Voltage Offset Correction: v_off_ini = 847.201 uV, v_off_fin = 847.357 uV 20:18:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.075 uVs 20:18:05 Integrated Voltage Measurement... 20:18:14 Voltage Offset Correction: v_off_ini = 849.997 uV, v_off_fin = 850.560 uV 20:18:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.400 uVs 20:18:19 I1Y Average and RMS of Measurements VT = -207.984 +- 2.017 uVs I1Y = -41.597 +- 0.403 uTm 20:18:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:18:24 Integrated Voltage Measurement... 20:18:33 Voltage Offset Correction: v_off_ini = 829.160 uV, v_off_fin = 836.630 uV 20:18:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.701 uVs 20:18:33 Integrated Voltage Measurement... 20:18:42 Voltage Offset Correction: v_off_ini = 830.554 uV, v_off_fin = 854.539 uV 20:18:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.900 uVs 20:18:42 Integrated Voltage Measurement... 20:18:51 Voltage Offset Correction: v_off_ini = 864.885 uV, v_off_fin = 861.368 uV 20:18:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.618 uVs 20:18:51 Integrated Voltage Measurement... 20:19:00 Voltage Offset Correction: v_off_ini = 837.074 uV, v_off_fin = 843.268 uV 20:19:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.066 uVs 20:19:00 Integrated Voltage Measurement... 20:19:09 Voltage Offset Correction: v_off_ini = 834.220 uV, v_off_fin = 847.683 uV 20:19:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.040 uVs 20:19:09 Integrated Voltage Measurement... 20:19:18 Voltage Offset Correction: v_off_ini = 859.610 uV, v_off_fin = 859.585 uV 20:19:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.616 uVs 20:19:20 I2X Average and RMS of Measurements VT = -30.824 +- 10.575 uVs I2X = 2.836 +- 0.973 uTm^2 20:19:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 20:19:25 Integrated Voltage Measurement... 20:19:34 Voltage Offset Correction: v_off_ini = 860.783 uV, v_off_fin = 859.216 uV 20:19:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.440 uVs 20:19:34 Integrated Voltage Measurement... 20:19:43 Voltage Offset Correction: v_off_ini = 850.934 uV, v_off_fin = 845.344 uV 20:19:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.661 uVs 20:19:43 Integrated Voltage Measurement... 20:19:52 Voltage Offset Correction: v_off_ini = 848.928 uV, v_off_fin = 849.484 uV 20:19:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.500 uVs 20:19:52 Integrated Voltage Measurement... 20:20:01 Voltage Offset Correction: v_off_ini = 851.285 uV, v_off_fin = 848.101 uV 20:20:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.685 uVs 20:20:01 Integrated Voltage Measurement... 20:20:10 Voltage Offset Correction: v_off_ini = 854.379 uV, v_off_fin = 841.645 uV 20:20:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.321 uVs 20:20:10 Integrated Voltage Measurement... 20:20:19 Voltage Offset Correction: v_off_ini = 852.393 uV, v_off_fin = 861.592 uV 20:20:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.500 uVs 20:20:22 I2Y Average and RMS of Measurements VT = -220.851 +- 3.453 uVs I2Y = -20.318 +- 0.318 uTm^2 20:20:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:20:30 Integrated Voltage Measurement... 20:20:39 Voltage Offset Correction: v_off_ini = 861.685 uV, v_off_fin = 839.984 uV 20:20:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -45.155 uVs 20:20:39 Integrated Voltage Measurement... 20:20:48 Voltage Offset Correction: v_off_ini = 837.977 uV, v_off_fin = 847.092 uV 20:20:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 49.848 uVs 20:20:48 Integrated Voltage Measurement... 20:20:57 Voltage Offset Correction: v_off_ini = 834.675 uV, v_off_fin = 846.972 uV 20:20:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.360 uVs 20:20:57 Integrated Voltage Measurement... 20:21:06 Voltage Offset Correction: v_off_ini = 835.680 uV, v_off_fin = 844.131 uV 20:21:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.241 uVs 20:21:06 Integrated Voltage Measurement... 20:21:15 Voltage Offset Correction: v_off_ini = 843.904 uV, v_off_fin = 836.503 uV 20:21:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -15.450 uVs 20:21:15 Integrated Voltage Measurement... 20:21:24 Voltage Offset Correction: v_off_ini = 835.309 uV, v_off_fin = 844.259 uV 20:21:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.328 uVs 20:21:28 I1X Average and RMS of Measurements VT = -36.897 +- 10.910 uVs I1X = 7.380 +- 2.183 uTm 20:21:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:21:35 Integrated Voltage Measurement... 20:21:44 Voltage Offset Correction: v_off_ini = 849.287 uV, v_off_fin = 836.020 uV 20:21:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.943 uVs 20:21:44 Integrated Voltage Measurement... 20:21:53 Voltage Offset Correction: v_off_ini = 846.130 uV, v_off_fin = 852.875 uV 20:21:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 203.275 uVs 20:21:53 Integrated Voltage Measurement... 20:22:02 Voltage Offset Correction: v_off_ini = 843.512 uV, v_off_fin = 835.264 uV 20:22:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -216.486 uVs 20:22:02 Integrated Voltage Measurement... 20:22:11 Voltage Offset Correction: v_off_ini = 849.287 uV, v_off_fin = 848.402 uV 20:22:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.549 uVs 20:22:11 Integrated Voltage Measurement... 20:22:20 Voltage Offset Correction: v_off_ini = 827.516 uV, v_off_fin = 828.660 uV 20:22:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -206.011 uVs 20:22:20 Integrated Voltage Measurement... 20:22:29 Voltage Offset Correction: v_off_ini = 848.872 uV, v_off_fin = 854.717 uV 20:22:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 205.560 uVs 20:22:33 I1Y Average and RMS of Measurements VT = -207.804 +- 4.097 uVs I1Y = -41.557 +- 0.819 uTm 20:22:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:22:38 Integrated Voltage Measurement... 20:22:47 Voltage Offset Correction: v_off_ini = 832.012 uV, v_off_fin = 826.246 uV 20:22:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -8.087 uVs 20:22:47 Integrated Voltage Measurement... 20:22:56 Voltage Offset Correction: v_off_ini = 841.848 uV, v_off_fin = 844.113 uV 20:22:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.372 uVs 20:22:56 Integrated Voltage Measurement... 20:23:05 Voltage Offset Correction: v_off_ini = 839.027 uV, v_off_fin = 832.361 uV 20:23:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.705 uVs 20:23:05 Integrated Voltage Measurement... 20:23:14 Voltage Offset Correction: v_off_ini = 832.710 uV, v_off_fin = 848.464 uV 20:23:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.404 uVs 20:23:14 Integrated Voltage Measurement... 20:23:23 Voltage Offset Correction: v_off_ini = 830.869 uV, v_off_fin = 830.769 uV 20:23:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -34.540 uVs 20:23:23 Integrated Voltage Measurement... 20:23:32 Voltage Offset Correction: v_off_ini = 827.668 uV, v_off_fin = 838.935 uV 20:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.855 uVs 20:23:34 I2X Average and RMS of Measurements VT = -30.661 +- 9.501 uVs I2X = 2.821 +- 0.874 uTm^2 20:23:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 20:23:40 Integrated Voltage Measurement... 20:23:49 Voltage Offset Correction: v_off_ini = 835.922 uV, v_off_fin = 849.928 uV 20:23:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.378 uVs 20:23:49 Integrated Voltage Measurement... 20:23:58 Voltage Offset Correction: v_off_ini = 851.011 uV, v_off_fin = 848.861 uV 20:23:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.569 uVs 20:23:58 Integrated Voltage Measurement... 20:24:07 Voltage Offset Correction: v_off_ini = 843.560 uV, v_off_fin = 843.684 uV 20:24:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.540 uVs 20:24:07 Integrated Voltage Measurement... 20:24:16 Voltage Offset Correction: v_off_ini = 858.765 uV, v_off_fin = 852.850 uV 20:24:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.092 uVs 20:24:16 Integrated Voltage Measurement... 20:24:25 Voltage Offset Correction: v_off_ini = 852.138 uV, v_off_fin = 846.256 uV 20:24:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.610 uVs 20:24:25 Integrated Voltage Measurement... 20:24:34 Voltage Offset Correction: v_off_ini = 854.826 uV, v_off_fin = 850.587 uV 20:24:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.080 uVs 20:24:36 I2Y Average and RMS of Measurements VT = -220.878 +- 9.243 uVs I2Y = -20.321 +- 0.850 uTm^2 20:24:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:24:44 Integrated Voltage Measurement... 20:24:53 Voltage Offset Correction: v_off_ini = 856.135 uV, v_off_fin = 863.528 uV 20:24:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -40.110 uVs 20:24:53 Integrated Voltage Measurement... 20:25:02 Voltage Offset Correction: v_off_ini = 877.596 uV, v_off_fin = 872.171 uV 20:25:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 23.002 uVs 20:25:02 Integrated Voltage Measurement... 20:25:11 Voltage Offset Correction: v_off_ini = 851.409 uV, v_off_fin = 846.822 uV 20:25:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.126 uVs 20:25:11 Integrated Voltage Measurement... 20:25:20 Voltage Offset Correction: v_off_ini = 858.016 uV, v_off_fin = 864.333 uV 20:25:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.292 uVs 20:25:20 Integrated Voltage Measurement... 20:25:29 Voltage Offset Correction: v_off_ini = 856.904 uV, v_off_fin = 839.703 uV 20:25:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.364 uVs 20:25:29 Integrated Voltage Measurement... 20:25:38 Voltage Offset Correction: v_off_ini = 847.558 uV, v_off_fin = 846.863 uV 20:25:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.206 uVs 20:25:43 I1X Average and RMS of Measurements VT = -39.350 +- 5.576 uVs I1X = 7.870 +- 1.115 uTm 20:25:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:25:49 Integrated Voltage Measurement... 20:25:58 Voltage Offset Correction: v_off_ini = 857.858 uV, v_off_fin = 853.794 uV 20:25:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.606 uVs 20:25:58 Integrated Voltage Measurement... 20:26:07 Voltage Offset Correction: v_off_ini = 841.142 uV, v_off_fin = 847.721 uV 20:26:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.252 uVs 20:26:07 Integrated Voltage Measurement... 20:26:16 Voltage Offset Correction: v_off_ini = 862.904 uV, v_off_fin = 847.052 uV 20:26:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.682 uVs 20:26:16 Integrated Voltage Measurement... 20:26:25 Voltage Offset Correction: v_off_ini = 860.150 uV, v_off_fin = 857.206 uV 20:26:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.956 uVs 20:26:25 Integrated Voltage Measurement... 20:26:34 Voltage Offset Correction: v_off_ini = 839.033 uV, v_off_fin = 848.374 uV 20:26:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.371 uVs 20:26:34 Integrated Voltage Measurement... 20:26:43 Voltage Offset Correction: v_off_ini = 857.162 uV, v_off_fin = 860.053 uV 20:26:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.494 uVs 20:26:48 I1Y Average and RMS of Measurements VT = -201.227 +- 6.339 uVs I1Y = -40.243 +- 1.269 uTm 20:26:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:26:53 Integrated Voltage Measurement... 20:27:02 Voltage Offset Correction: v_off_ini = 838.591 uV, v_off_fin = 844.667 uV 20:27:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.549 uVs 20:27:02 Integrated Voltage Measurement... 20:27:11 Voltage Offset Correction: v_off_ini = 849.874 uV, v_off_fin = 855.478 uV 20:27:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.651 uVs 20:27:11 Integrated Voltage Measurement... 20:27:20 Voltage Offset Correction: v_off_ini = 861.941 uV, v_off_fin = 848.407 uV 20:27:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.112 uVs 20:27:20 Integrated Voltage Measurement... 20:27:29 Voltage Offset Correction: v_off_ini = 857.711 uV, v_off_fin = 858.831 uV 20:27:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 26.538 uVs 20:27:29 Integrated Voltage Measurement... 20:27:38 Voltage Offset Correction: v_off_ini = 851.992 uV, v_off_fin = 840.889 uV 20:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.371 uVs 20:27:38 Integrated Voltage Measurement... 20:27:47 Voltage Offset Correction: v_off_ini = 846.299 uV, v_off_fin = 862.573 uV 20:27:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.604 uVs 20:27:49 I2X Average and RMS of Measurements VT = -30.304 +- 5.204 uVs I2X = 2.788 +- 0.479 uTm^2 20:27:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 20:27:54 Integrated Voltage Measurement... 20:28:03 Voltage Offset Correction: v_off_ini = 858.047 uV, v_off_fin = 848.301 uV 20:28:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.302 uVs 20:28:03 Integrated Voltage Measurement... 20:28:12 Voltage Offset Correction: v_off_ini = 847.026 uV, v_off_fin = 859.906 uV 20:28:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.417 uVs 20:28:12 Integrated Voltage Measurement... 20:28:21 Voltage Offset Correction: v_off_ini = 861.537 uV, v_off_fin = 864.924 uV 20:28:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.299 uVs 20:28:21 Integrated Voltage Measurement... 20:28:30 Voltage Offset Correction: v_off_ini = 854.974 uV, v_off_fin = 862.757 uV 20:28:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.409 uVs 20:28:30 Integrated Voltage Measurement... 20:28:39 Voltage Offset Correction: v_off_ini = 863.088 uV, v_off_fin = 859.728 uV 20:28:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.575 uVs 20:28:40 Integrated Voltage Measurement... 20:28:48 Voltage Offset Correction: v_off_ini = 862.199 uV, v_off_fin = 862.152 uV 20:28:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.011 uVs 20:28:51 I2Y Average and RMS of Measurements VT = -223.169 +- 3.703 uVs I2Y = -20.532 +- 0.341 uTm^2 20:28:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:28:32 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm