SLAC Magnetic Measurements Date: 11-07-2025 Time: 13:52:00 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16349 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 3 Measurement Device: Stretched Wire Operator: YL Comment: 13:52:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:11 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:52:12 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:52:14 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:52:16 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:52:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:01 Integrated Voltage Measurement... 13:53:10 Voltage Offset Correction: v_off_ini = -180.565 uV, v_off_fin = -185.458 uV 13:53:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.369 uVs 13:53:10 Integrated Voltage Measurement... 13:53:19 Voltage Offset Correction: v_off_ini = -186.630 uV, v_off_fin = -186.219 uV 13:53:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.528 uVs 13:53:19 Integrated Voltage Measurement... 13:53:28 Voltage Offset Correction: v_off_ini = -196.298 uV, v_off_fin = -204.581 uV 13:53:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.799 uVs 13:53:28 Integrated Voltage Measurement... 13:53:37 Voltage Offset Correction: v_off_ini = -189.814 uV, v_off_fin = -180.066 uV 13:53:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.919 uVs 13:53:37 Integrated Voltage Measurement... 13:53:46 Voltage Offset Correction: v_off_ini = -195.441 uV, v_off_fin = -194.706 uV 13:53:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.945 uVs 13:53:46 Integrated Voltage Measurement... 13:53:55 Voltage Offset Correction: v_off_ini = -199.351 uV, v_off_fin = -195.203 uV 13:53:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.664 uVs 13:53:59 I1X Average and RMS of Measurements VT = -55.537 +- 5.895 uVs I1X = 11.107 +- 1.179 uTm 13:54:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:54:06 Integrated Voltage Measurement... 13:54:15 Voltage Offset Correction: v_off_ini = -185.280 uV, v_off_fin = -208.377 uV 13:54:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.138 uVs 13:54:15 Integrated Voltage Measurement... 13:54:24 Voltage Offset Correction: v_off_ini = -198.850 uV, v_off_fin = -177.370 uV 13:54:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.373 uVs 13:54:24 Integrated Voltage Measurement... 13:54:33 Voltage Offset Correction: v_off_ini = -190.222 uV, v_off_fin = -203.620 uV 13:54:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.642 uVs 13:54:33 Integrated Voltage Measurement... 13:54:42 Voltage Offset Correction: v_off_ini = -191.053 uV, v_off_fin = -163.148 uV 13:54:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5002 mm dXY = -0.5001 mm VT = 192.869 uVs 13:54:42 Integrated Voltage Measurement... 13:54:51 Voltage Offset Correction: v_off_ini = -181.667 uV, v_off_fin = -194.395 uV 13:54:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -195.417 uVs 13:54:51 Integrated Voltage Measurement... 13:55:00 Voltage Offset Correction: v_off_ini = -199.511 uV, v_off_fin = -181.644 uV 13:55:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.478 uVs 13:55:04 I1Y Average and RMS of Measurements VT = -198.486 +- 1.766 uVs I1Y = -39.695 +- 0.352 uTm 13:55:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:12 Integrated Voltage Measurement... 13:55:21 Voltage Offset Correction: v_off_ini = -164.818 uV, v_off_fin = -163.472 uV 13:55:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.196 uVs 13:55:21 Integrated Voltage Measurement... 13:55:30 Voltage Offset Correction: v_off_ini = -149.453 uV, v_off_fin = -130.839 uV 13:55:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.526 uVs 13:55:30 Integrated Voltage Measurement... 13:55:39 Voltage Offset Correction: v_off_ini = -132.867 uV, v_off_fin = -128.044 uV 13:55:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.503 uVs 13:55:39 Integrated Voltage Measurement... 13:55:48 Voltage Offset Correction: v_off_ini = -123.455 uV, v_off_fin = -120.205 uV 13:55:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.803 uVs 13:55:48 Integrated Voltage Measurement... 13:55:57 Voltage Offset Correction: v_off_ini = -122.553 uV, v_off_fin = -135.764 uV 13:55:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.166 uVs 13:55:57 Integrated Voltage Measurement... 13:56:06 Voltage Offset Correction: v_off_ini = -127.548 uV, v_off_fin = -115.819 uV 13:56:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.623 uVs 13:56:08 I2X Average and RMS of Measurements VT = -59.970 +- 6.460 uVs I2X = 5.517 +- 0.594 uTm^2 13:56:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:16 Integrated Voltage Measurement... 13:56:25 Voltage Offset Correction: v_off_ini = -109.696 uV, v_off_fin = -102.003 uV 13:56:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -349.418 uVs 13:56:25 Integrated Voltage Measurement... 13:56:34 Voltage Offset Correction: v_off_ini = -111.772 uV, v_off_fin = -114.651 uV 13:56:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.611 uVs 13:56:34 Integrated Voltage Measurement... 13:56:43 Voltage Offset Correction: v_off_ini = -118.938 uV, v_off_fin = -123.849 uV 13:56:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.597 uVs 13:56:43 Integrated Voltage Measurement... 13:56:52 Voltage Offset Correction: v_off_ini = -113.797 uV, v_off_fin = -109.270 uV 13:56:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.898 uVs 13:56:52 Integrated Voltage Measurement... 13:57:01 Voltage Offset Correction: v_off_ini = -116.285 uV, v_off_fin = -107.483 uV 13:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.109 uVs 13:57:01 Integrated Voltage Measurement... 13:57:10 Voltage Offset Correction: v_off_ini = -107.334 uV, v_off_fin = -98.070 uV 13:57:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.756 uVs 13:57:13 I2Y Average and RMS of Measurements VT = -324.232 +- 12.222 uVs I2Y = -29.829 +- 1.124 uTm^2 13:57:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:28 Integrated Voltage Measurement... 13:57:37 Voltage Offset Correction: v_off_ini = -105.020 uV, v_off_fin = -99.386 uV 13:57:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -43.263 uVs 13:57:37 Integrated Voltage Measurement... 13:57:46 Voltage Offset Correction: v_off_ini = -94.688 uV, v_off_fin = -100.735 uV 13:57:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.578 uVs 13:57:46 Integrated Voltage Measurement... 13:57:55 Voltage Offset Correction: v_off_ini = -75.872 uV, v_off_fin = -81.776 uV 13:57:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.311 uVs 13:57:55 Integrated Voltage Measurement... 13:58:04 Voltage Offset Correction: v_off_ini = -74.844 uV, v_off_fin = -66.379 uV 13:58:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.925 uVs 13:58:04 Integrated Voltage Measurement... 13:58:13 Voltage Offset Correction: v_off_ini = -76.462 uV, v_off_fin = -82.532 uV 13:58:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.837 uVs 13:58:13 Integrated Voltage Measurement... 13:58:22 Voltage Offset Correction: v_off_ini = -83.227 uV, v_off_fin = -78.621 uV 13:58:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.695 uVs 13:58:26 I1X Average and RMS of Measurements VT = -69.602 +- 6.306 uVs I1X = 13.920 +- 1.261 uTm 13:58:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:33 Integrated Voltage Measurement... 13:58:42 Voltage Offset Correction: v_off_ini = -76.637 uV, v_off_fin = -91.929 uV 13:58:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.468 uVs 13:58:42 Integrated Voltage Measurement... 13:58:51 Voltage Offset Correction: v_off_ini = -96.435 uV, v_off_fin = -74.376 uV 13:58:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.210 uVs 13:58:51 Integrated Voltage Measurement... 13:59:00 Voltage Offset Correction: v_off_ini = -91.886 uV, v_off_fin = -102.387 uV 13:59:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.084 uVs 13:59:00 Integrated Voltage Measurement... 13:59:09 Voltage Offset Correction: v_off_ini = -91.744 uV, v_off_fin = -78.045 uV 13:59:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 210.507 uVs 13:59:09 Integrated Voltage Measurement... 13:59:18 Voltage Offset Correction: v_off_ini = -84.399 uV, v_off_fin = -86.318 uV 13:59:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -179.393 uVs 13:59:18 Integrated Voltage Measurement... 13:59:27 Voltage Offset Correction: v_off_ini = -85.863 uV, v_off_fin = -73.273 uV 13:59:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.804 uVs 13:59:31 I1Y Average and RMS of Measurements VT = -190.245 +- 7.221 uVs I1Y = -38.046 +- 1.443 uTm 13:59:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:59:39 Integrated Voltage Measurement... 13:59:48 Voltage Offset Correction: v_off_ini = -83.234 uV, v_off_fin = -78.414 uV 13:59:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.517 uVs 13:59:48 Integrated Voltage Measurement... 13:59:57 Voltage Offset Correction: v_off_ini = -82.817 uV, v_off_fin = -85.271 uV 13:59:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.167 uVs 13:59:57 Integrated Voltage Measurement... 14:00:06 Voltage Offset Correction: v_off_ini = -74.938 uV, v_off_fin = -87.739 uV 14:00:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.828 uVs 14:00:06 Integrated Voltage Measurement... 14:00:15 Voltage Offset Correction: v_off_ini = -76.275 uV, v_off_fin = -70.289 uV 14:00:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.243 uVs 14:00:15 Integrated Voltage Measurement... 14:00:24 Voltage Offset Correction: v_off_ini = -74.827 uV, v_off_fin = -78.853 uV 14:00:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.700 uVs 14:00:24 Integrated Voltage Measurement... 14:00:33 Voltage Offset Correction: v_off_ini = -66.753 uV, v_off_fin = -61.675 uV 14:00:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.598 uVs 14:00:35 I2X Average and RMS of Measurements VT = -74.842 +- 7.094 uVs I2X = 6.885 +- 0.653 uTm^2 14:00:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:43 Integrated Voltage Measurement... 14:00:52 Voltage Offset Correction: v_off_ini = -78.283 uV, v_off_fin = -61.262 uV 14:00:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -310.426 uVs 14:00:52 Integrated Voltage Measurement... 14:01:01 Voltage Offset Correction: v_off_ini = -68.903 uV, v_off_fin = -65.630 uV 14:01:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.036 uVs 14:01:01 Integrated Voltage Measurement... 14:01:10 Voltage Offset Correction: v_off_ini = -70.971 uV, v_off_fin = -71.288 uV 14:01:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.114 uVs 14:01:10 Integrated Voltage Measurement... 14:01:19 Voltage Offset Correction: v_off_ini = -60.108 uV, v_off_fin = -61.451 uV 14:01:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.683 uVs 14:01:19 Integrated Voltage Measurement... 14:01:28 Voltage Offset Correction: v_off_ini = -66.403 uV, v_off_fin = -64.238 uV 14:01:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.031 uVs 14:01:28 Integrated Voltage Measurement... 14:01:37 Voltage Offset Correction: v_off_ini = -61.966 uV, v_off_fin = -58.978 uV 14:01:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.348 uVs 14:01:40 I2Y Average and RMS of Measurements VT = -312.940 +- 3.911 uVs I2Y = -28.790 +- 0.360 uTm^2 14:01:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:55 Integrated Voltage Measurement... 14:02:04 Voltage Offset Correction: v_off_ini = -57.590 uV, v_off_fin = -76.127 uV 14:02:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.784 uVs 14:02:04 Integrated Voltage Measurement... 14:02:13 Voltage Offset Correction: v_off_ini = -67.074 uV, v_off_fin = -54.946 uV 14:02:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.511 uVs 14:02:13 Integrated Voltage Measurement... 14:02:22 Voltage Offset Correction: v_off_ini = -61.147 uV, v_off_fin = -65.511 uV 14:02:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.182 uVs 14:02:22 Integrated Voltage Measurement... 14:02:31 Voltage Offset Correction: v_off_ini = -57.642 uV, v_off_fin = -50.490 uV 14:02:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.645 uVs 14:02:31 Integrated Voltage Measurement... 14:02:40 Voltage Offset Correction: v_off_ini = -50.311 uV, v_off_fin = -61.457 uV 14:02:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.575 uVs 14:02:40 Integrated Voltage Measurement... 14:02:49 Voltage Offset Correction: v_off_ini = -54.956 uV, v_off_fin = -63.130 uV 14:02:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.162 uVs 14:02:53 I1X Average and RMS of Measurements VT = -74.310 +- 1.864 uVs I1X = 14.862 +- 0.373 uTm 14:02:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:03:00 Integrated Voltage Measurement... 14:03:09 Voltage Offset Correction: v_off_ini = -51.553 uV, v_off_fin = -61.115 uV 14:03:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -186.066 uVs 14:03:09 Integrated Voltage Measurement... 14:03:18 Voltage Offset Correction: v_off_ini = -49.455 uV, v_off_fin = -36.739 uV 14:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.820 uVs 14:03:18 Integrated Voltage Measurement... 14:03:27 Voltage Offset Correction: v_off_ini = -46.970 uV, v_off_fin = -64.977 uV 14:03:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.402 uVs 14:03:27 Integrated Voltage Measurement... 14:03:36 Voltage Offset Correction: v_off_ini = -50.140 uV, v_off_fin = -44.558 uV 14:03:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.404 uVs 14:03:36 Integrated Voltage Measurement... 14:03:45 Voltage Offset Correction: v_off_ini = -64.975 uV, v_off_fin = -70.068 uV 14:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.597 uVs 14:03:45 Integrated Voltage Measurement... 14:03:54 Voltage Offset Correction: v_off_ini = -46.321 uV, v_off_fin = -43.206 uV 14:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.759 uVs 14:03:58 I1Y Average and RMS of Measurements VT = -183.508 +- 5.068 uVs I1Y = -36.700 +- 1.012 uTm 14:04:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:04:06 Integrated Voltage Measurement... 14:04:15 Voltage Offset Correction: v_off_ini = -60.917 uV, v_off_fin = -68.876 uV 14:04:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.951 uVs 14:04:15 Integrated Voltage Measurement... 14:04:24 Voltage Offset Correction: v_off_ini = -49.938 uV, v_off_fin = -42.409 uV 14:04:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.415 uVs 14:04:24 Integrated Voltage Measurement... 14:04:33 Voltage Offset Correction: v_off_ini = -52.292 uV, v_off_fin = -60.089 uV 14:04:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.121 uVs 14:04:33 Integrated Voltage Measurement... 14:04:42 Voltage Offset Correction: v_off_ini = -45.022 uV, v_off_fin = -32.818 uV 14:04:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.807 uVs 14:04:42 Integrated Voltage Measurement... 14:04:51 Voltage Offset Correction: v_off_ini = -33.701 uV, v_off_fin = -46.042 uV 14:04:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.318 uVs 14:04:51 Integrated Voltage Measurement... 14:05:00 Voltage Offset Correction: v_off_ini = -29.805 uV, v_off_fin = -37.118 uV 14:05:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.069 uVs 14:05:03 I2X Average and RMS of Measurements VT = -77.780 +- 5.764 uVs I2X = 7.156 +- 0.530 uTm^2 14:05:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:05:10 Integrated Voltage Measurement... 14:05:19 Voltage Offset Correction: v_off_ini = -46.618 uV, v_off_fin = -37.145 uV 14:05:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.625 uVs 14:05:19 Integrated Voltage Measurement... 14:05:28 Voltage Offset Correction: v_off_ini = -45.519 uV, v_off_fin = -36.430 uV 14:05:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.603 uVs 14:05:28 Integrated Voltage Measurement... 14:05:37 Voltage Offset Correction: v_off_ini = -29.378 uV, v_off_fin = -29.374 uV 14:05:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.754 uVs 14:05:38 Integrated Voltage Measurement... 14:05:46 Voltage Offset Correction: v_off_ini = -34.046 uV, v_off_fin = -39.143 uV 14:05:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.923 uVs 14:05:47 Integrated Voltage Measurement... 14:05:56 Voltage Offset Correction: v_off_ini = -32.393 uV, v_off_fin = -35.190 uV 14:05:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.263 uVs 14:05:56 Integrated Voltage Measurement... 14:06:05 Voltage Offset Correction: v_off_ini = -32.347 uV, v_off_fin = -33.399 uV 14:06:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.854 uVs 14:06:07 I2Y Average and RMS of Measurements VT = -305.503 +- 3.765 uVs I2Y = -28.106 +- 0.346 uTm^2 14:06:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:22 Integrated Voltage Measurement... 14:06:31 Voltage Offset Correction: v_off_ini = -20.411 uV, v_off_fin = -33.208 uV 14:06:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -92.737 uVs 14:06:31 Integrated Voltage Measurement... 14:06:40 Voltage Offset Correction: v_off_ini = -53.810 uV, v_off_fin = -39.560 uV 14:06:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.603 uVs 14:06:40 Integrated Voltage Measurement... 14:06:49 Voltage Offset Correction: v_off_ini = -43.221 uV, v_off_fin = -41.372 uV 14:06:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.523 uVs 14:06:49 Integrated Voltage Measurement... 14:06:58 Voltage Offset Correction: v_off_ini = -44.386 uV, v_off_fin = -42.091 uV 14:06:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.150 uVs 14:06:58 Integrated Voltage Measurement... 14:07:07 Voltage Offset Correction: v_off_ini = -58.336 uV, v_off_fin = -47.036 uV 14:07:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.894 uVs 14:07:07 Integrated Voltage Measurement... 14:07:16 Voltage Offset Correction: v_off_ini = -40.536 uV, v_off_fin = -34.496 uV 14:07:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.578 uVs 14:07:20 I1X Average and RMS of Measurements VT = -81.581 +- 6.668 uVs I1X = 16.317 +- 1.334 uTm 14:07:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:27 Integrated Voltage Measurement... 14:07:36 Voltage Offset Correction: v_off_ini = -54.205 uV, v_off_fin = -55.571 uV 14:07:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.524 uVs 14:07:36 Integrated Voltage Measurement... 14:07:45 Voltage Offset Correction: v_off_ini = -45.180 uV, v_off_fin = -29.940 uV 14:07:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 189.527 uVs 14:07:45 Integrated Voltage Measurement... 14:07:54 Voltage Offset Correction: v_off_ini = -47.094 uV, v_off_fin = -51.850 uV 14:07:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -169.147 uVs 14:07:54 Integrated Voltage Measurement... 14:08:03 Voltage Offset Correction: v_off_ini = -39.105 uV, v_off_fin = -26.987 uV 14:08:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.914 uVs 14:08:03 Integrated Voltage Measurement... 14:08:12 Voltage Offset Correction: v_off_ini = -35.420 uV, v_off_fin = -49.048 uV 14:08:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.445 uVs 14:08:12 Integrated Voltage Measurement... 14:08:21 Voltage Offset Correction: v_off_ini = -33.305 uV, v_off_fin = -25.528 uV 14:08:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 197.330 uVs 14:08:25 I1Y Average and RMS of Measurements VT = -185.148 +- 6.010 uVs I1Y = -37.026 +- 1.202 uTm 14:08:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:33 Integrated Voltage Measurement... 14:08:42 Voltage Offset Correction: v_off_ini = -42.658 uV, v_off_fin = -40.698 uV 14:08:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -60.851 uVs 14:08:42 Integrated Voltage Measurement... 14:08:51 Voltage Offset Correction: v_off_ini = -22.115 uV, v_off_fin = -16.212 uV 14:08:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.709 uVs 14:08:51 Integrated Voltage Measurement... 14:09:00 Voltage Offset Correction: v_off_ini = -23.888 uV, v_off_fin = -30.224 uV 14:09:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.899 uVs 14:09:00 Integrated Voltage Measurement... 14:09:09 Voltage Offset Correction: v_off_ini = -38.759 uV, v_off_fin = -29.812 uV 14:09:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.627 uVs 14:09:09 Integrated Voltage Measurement... 14:09:18 Voltage Offset Correction: v_off_ini = -19.856 uV, v_off_fin = -25.432 uV 14:09:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.690 uVs 14:09:18 Integrated Voltage Measurement... 14:09:27 Voltage Offset Correction: v_off_ini = -20.179 uV, v_off_fin = -18.093 uV 14:09:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 110.741 uVs 14:09:30 I2X Average and RMS of Measurements VT = -90.920 +- 15.690 uVs I2X = 8.365 +- 1.443 uTm^2 14:09:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:38 Integrated Voltage Measurement... 14:09:47 Voltage Offset Correction: v_off_ini = -26.578 uV, v_off_fin = -23.911 uV 14:09:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.787 uVs 14:09:47 Integrated Voltage Measurement... 14:09:56 Voltage Offset Correction: v_off_ini = -20.527 uV, v_off_fin = -16.713 uV 14:09:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.759 uVs 14:09:56 Integrated Voltage Measurement... 14:10:05 Voltage Offset Correction: v_off_ini = -20.623 uV, v_off_fin = -18.324 uV 14:10:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.591 uVs 14:10:05 Integrated Voltage Measurement... 14:10:14 Voltage Offset Correction: v_off_ini = -12.529 uV, v_off_fin = -16.877 uV 14:10:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.375 uVs 14:10:14 Integrated Voltage Measurement... 14:10:23 Voltage Offset Correction: v_off_ini = -24.960 uV, v_off_fin = -16.706 uV 14:10:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.606 uVs 14:10:23 Integrated Voltage Measurement... 14:10:32 Voltage Offset Correction: v_off_ini = -15.885 uV, v_off_fin = -13.559 uV 14:10:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.968 uVs 14:10:34 I2Y Average and RMS of Measurements VT = -293.348 +- 6.282 uVs I2Y = -26.988 +- 0.578 uTm^2 14:10:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:10:49 Integrated Voltage Measurement... 14:10:58 Voltage Offset Correction: v_off_ini = -1.593 uV, v_off_fin = -8.413 uV 14:10:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.970 uVs 14:10:58 Integrated Voltage Measurement... 14:11:07 Voltage Offset Correction: v_off_ini = -22.608 uV, v_off_fin = -20.359 uV 14:11:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.069 uVs 14:11:07 Integrated Voltage Measurement... 14:11:16 Voltage Offset Correction: v_off_ini = -24.227 uV, v_off_fin = -19.861 uV 14:11:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.999 uVs 14:11:16 Integrated Voltage Measurement... 14:11:25 Voltage Offset Correction: v_off_ini = -9.224 uV, v_off_fin = -25.679 uV 14:11:25 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 94.391 uVs 14:11:25 Integrated Voltage Measurement... 14:11:34 Voltage Offset Correction: v_off_ini = -25.336 uV, v_off_fin = -33.096 uV 14:11:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.393 uVs 14:11:34 Integrated Voltage Measurement... 14:11:43 Voltage Offset Correction: v_off_ini = -28.737 uV, v_off_fin = -40.764 uV 14:11:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.325 uVs 14:11:47 I1X Average and RMS of Measurements VT = -93.191 +- 3.073 uVs I1X = 18.640 +- 0.614 uTm 14:11:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:11:54 Integrated Voltage Measurement... 14:12:03 Voltage Offset Correction: v_off_ini = -34.331 uV, v_off_fin = -54.779 uV 14:12:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.308 uVs 14:12:03 Integrated Voltage Measurement... 14:12:12 Voltage Offset Correction: v_off_ini = -37.106 uV, v_off_fin = -32.899 uV 14:12:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.997 uVs 14:12:12 Integrated Voltage Measurement... 14:12:21 Voltage Offset Correction: v_off_ini = -30.849 uV, v_off_fin = -50.628 uV 14:12:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.333 uVs 14:12:21 Integrated Voltage Measurement... 14:12:30 Voltage Offset Correction: v_off_ini = -35.330 uV, v_off_fin = -22.798 uV 14:12:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.877 uVs 14:12:30 Integrated Voltage Measurement... 14:12:39 Voltage Offset Correction: v_off_ini = -27.199 uV, v_off_fin = -56.504 uV 14:12:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.591 uVs 14:12:39 Integrated Voltage Measurement... 14:12:48 Voltage Offset Correction: v_off_ini = -46.228 uV, v_off_fin = -43.897 uV 14:12:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.719 uVs 14:12:52 I1Y Average and RMS of Measurements VT = -182.471 +- 7.942 uVs I1Y = -36.491 +- 1.587 uTm 14:12:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:13:00 Integrated Voltage Measurement... 14:13:09 Voltage Offset Correction: v_off_ini = -46.966 uV, v_off_fin = -63.033 uV 14:13:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.914 uVs 14:13:09 Integrated Voltage Measurement... 14:13:18 Voltage Offset Correction: v_off_ini = -43.419 uV, v_off_fin = -40.554 uV 14:13:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.233 uVs 14:13:18 Integrated Voltage Measurement... 14:13:27 Voltage Offset Correction: v_off_ini = -53.615 uV, v_off_fin = -58.833 uV 14:13:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.577 uVs 14:13:27 Integrated Voltage Measurement... 14:13:36 Voltage Offset Correction: v_off_ini = -50.319 uV, v_off_fin = -41.656 uV 14:13:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.055 uVs 14:13:36 Integrated Voltage Measurement... 14:13:45 Voltage Offset Correction: v_off_ini = -43.415 uV, v_off_fin = -50.070 uV 14:13:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.894 uVs 14:13:45 Integrated Voltage Measurement... 14:13:54 Voltage Offset Correction: v_off_ini = -57.920 uV, v_off_fin = -46.305 uV 14:13:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.838 uVs 14:13:57 I2X Average and RMS of Measurements VT = -104.585 +- 2.890 uVs I2X = 9.622 +- 0.266 uTm^2 14:14:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:04 Integrated Voltage Measurement... 14:14:13 Voltage Offset Correction: v_off_ini = -37.498 uV, v_off_fin = -33.435 uV 14:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.719 uVs 14:14:13 Integrated Voltage Measurement... 14:14:22 Voltage Offset Correction: v_off_ini = -37.563 uV, v_off_fin = -37.884 uV 14:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.509 uVs 14:14:23 Integrated Voltage Measurement... 14:14:32 Voltage Offset Correction: v_off_ini = -46.324 uV, v_off_fin = -50.678 uV 14:14:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.785 uVs 14:14:32 Integrated Voltage Measurement... 14:14:41 Voltage Offset Correction: v_off_ini = -40.097 uV, v_off_fin = -45.013 uV 14:14:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.185 uVs 14:14:41 Integrated Voltage Measurement... 14:14:50 Voltage Offset Correction: v_off_ini = -45.828 uV, v_off_fin = -38.590 uV 14:14:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.034 uVs 14:14:50 Integrated Voltage Measurement... 14:14:59 Voltage Offset Correction: v_off_ini = -45.004 uV, v_off_fin = -36.106 uV 14:14:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.861 uVs 14:15:01 I2Y Average and RMS of Measurements VT = -286.349 +- 10.088 uVs I2Y = -26.344 +- 0.928 uTm^2 14:15:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:15:16 Integrated Voltage Measurement... 14:15:25 Voltage Offset Correction: v_off_ini = -49.676 uV, v_off_fin = -51.026 uV 14:15:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -96.218 uVs 14:15:25 Integrated Voltage Measurement... 14:15:34 Voltage Offset Correction: v_off_ini = -41.436 uV, v_off_fin = -42.935 uV 14:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.722 uVs 14:15:34 Integrated Voltage Measurement... 14:15:43 Voltage Offset Correction: v_off_ini = -51.013 uV, v_off_fin = -54.339 uV 14:15:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.624 uVs 14:15:43 Integrated Voltage Measurement... 14:15:52 Voltage Offset Correction: v_off_ini = -49.609 uV, v_off_fin = -46.097 uV 14:15:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.258 uVs 14:15:52 Integrated Voltage Measurement... 14:16:01 Voltage Offset Correction: v_off_ini = -45.257 uV, v_off_fin = -41.957 uV 14:16:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.544 uVs 14:16:01 Integrated Voltage Measurement... 14:16:10 Voltage Offset Correction: v_off_ini = -31.393 uV, v_off_fin = -45.742 uV 14:16:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.492 uVs 14:16:14 I1X Average and RMS of Measurements VT = -101.643 +- 7.292 uVs I1X = 20.330 +- 1.458 uTm 14:16:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:21 Integrated Voltage Measurement... 14:16:30 Voltage Offset Correction: v_off_ini = -47.639 uV, v_off_fin = -54.435 uV 14:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -185.638 uVs 14:16:30 Integrated Voltage Measurement... 14:16:39 Voltage Offset Correction: v_off_ini = -26.538 uV, v_off_fin = -27.344 uV 14:16:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.455 uVs 14:16:39 Integrated Voltage Measurement... 14:16:48 Voltage Offset Correction: v_off_ini = -38.235 uV, v_off_fin = -49.194 uV 14:16:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.302 uVs 14:16:48 Integrated Voltage Measurement... 14:16:57 Voltage Offset Correction: v_off_ini = -43.770 uV, v_off_fin = -25.900 uV 14:16:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.849 uVs 14:16:57 Integrated Voltage Measurement... 14:17:06 Voltage Offset Correction: v_off_ini = -47.852 uV, v_off_fin = -51.258 uV 14:17:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.413 uVs 14:17:06 Integrated Voltage Measurement... 14:17:15 Voltage Offset Correction: v_off_ini = -57.208 uV, v_off_fin = -32.298 uV 14:17:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.291 uVs 14:17:19 I1Y Average and RMS of Measurements VT = -183.825 +- 1.262 uVs I1Y = -36.762 +- 0.252 uTm 14:17:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:27 Integrated Voltage Measurement... 14:17:36 Voltage Offset Correction: v_off_ini = -26.936 uV, v_off_fin = -53.811 uV 14:17:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -111.535 uVs 14:17:36 Integrated Voltage Measurement... 14:17:45 Voltage Offset Correction: v_off_ini = -37.673 uV, v_off_fin = -32.617 uV 14:17:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.827 uVs 14:17:45 Integrated Voltage Measurement... 14:17:54 Voltage Offset Correction: v_off_ini = -29.356 uV, v_off_fin = -37.368 uV 14:17:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -108.805 uVs 14:17:54 Integrated Voltage Measurement... 14:18:03 Voltage Offset Correction: v_off_ini = -27.952 uV, v_off_fin = -19.496 uV 14:18:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 108.140 uVs 14:18:03 Integrated Voltage Measurement... 14:18:12 Voltage Offset Correction: v_off_ini = -43.871 uV, v_off_fin = -46.509 uV 14:18:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.252 uVs 14:18:12 Integrated Voltage Measurement... 14:18:21 Voltage Offset Correction: v_off_ini = -37.367 uV, v_off_fin = -30.417 uV 14:18:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.486 uVs 14:18:24 I2X Average and RMS of Measurements VT = -104.674 +- 4.490 uVs I2X = 9.631 +- 0.413 uTm^2 14:18:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:31 Integrated Voltage Measurement... 14:18:40 Voltage Offset Correction: v_off_ini = -34.322 uV, v_off_fin = -22.422 uV 14:18:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -290.055 uVs 14:18:40 Integrated Voltage Measurement... 14:18:49 Voltage Offset Correction: v_off_ini = -23.430 uV, v_off_fin = -32.106 uV 14:18:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.542 uVs 14:18:49 Integrated Voltage Measurement... 14:18:58 Voltage Offset Correction: v_off_ini = -23.313 uV, v_off_fin = -34.176 uV 14:18:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.006 uVs 14:18:58 Integrated Voltage Measurement... 14:19:07 Voltage Offset Correction: v_off_ini = -28.340 uV, v_off_fin = -25.920 uV 14:19:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.366 uVs 14:19:07 Integrated Voltage Measurement... 14:19:16 Voltage Offset Correction: v_off_ini = -32.653 uV, v_off_fin = -33.501 uV 14:19:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.896 uVs 14:19:17 Integrated Voltage Measurement... 14:19:26 Voltage Offset Correction: v_off_ini = -30.116 uV, v_off_fin = -27.397 uV 14:19:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.857 uVs 14:19:28 I2Y Average and RMS of Measurements VT = -278.120 +- 4.378 uVs I2Y = -25.588 +- 0.403 uTm^2 14:19:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:43 Integrated Voltage Measurement... 14:19:52 Voltage Offset Correction: v_off_ini = -26.299 uV, v_off_fin = -44.458 uV 14:19:52 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -105.771 uVs 14:19:52 Integrated Voltage Measurement... 14:20:01 Voltage Offset Correction: v_off_ini = -47.324 uV, v_off_fin = -32.152 uV 14:20:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.918 uVs 14:20:01 Integrated Voltage Measurement... 14:20:10 Voltage Offset Correction: v_off_ini = -35.263 uV, v_off_fin = -39.709 uV 14:20:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.690 uVs 14:20:10 Integrated Voltage Measurement... 14:20:19 Voltage Offset Correction: v_off_ini = -39.255 uV, v_off_fin = -35.914 uV 14:20:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.620 uVs 14:20:19 Integrated Voltage Measurement... 14:20:28 Voltage Offset Correction: v_off_ini = -47.652 uV, v_off_fin = -51.260 uV 14:20:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.482 uVs 14:20:28 Integrated Voltage Measurement... 14:20:37 Voltage Offset Correction: v_off_ini = -38.829 uV, v_off_fin = -32.205 uV 14:20:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.455 uVs 14:20:41 I1X Average and RMS of Measurements VT = -100.656 +- 5.902 uVs I1X = 20.134 +- 1.181 uTm 14:20:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:48 Integrated Voltage Measurement... 14:20:57 Voltage Offset Correction: v_off_ini = -50.340 uV, v_off_fin = -47.935 uV 14:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -159.579 uVs 14:20:57 Integrated Voltage Measurement... 14:21:06 Voltage Offset Correction: v_off_ini = -30.176 uV, v_off_fin = -18.581 uV 14:21:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.390 uVs 14:21:06 Integrated Voltage Measurement... 14:21:15 Voltage Offset Correction: v_off_ini = -36.744 uV, v_off_fin = -38.876 uV 14:21:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.934 uVs 14:21:15 Integrated Voltage Measurement... 14:21:24 Voltage Offset Correction: v_off_ini = -26.771 uV, v_off_fin = -8.041 uV 14:21:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.345 uVs 14:21:24 Integrated Voltage Measurement... 14:21:33 Voltage Offset Correction: v_off_ini = -21.707 uV, v_off_fin = -38.124 uV 14:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.412 uVs 14:21:33 Integrated Voltage Measurement... 14:21:42 Voltage Offset Correction: v_off_ini = -29.059 uV, v_off_fin = -14.878 uV 14:21:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.414 uVs 14:21:46 I1Y Average and RMS of Measurements VT = -172.679 +- 1.909 uVs I1Y = -34.533 +- 0.383 uTm 14:21:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:21:54 Integrated Voltage Measurement... 14:22:03 Voltage Offset Correction: v_off_ini = -23.405 uV, v_off_fin = -34.225 uV 14:22:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.013 uVs 14:22:03 Integrated Voltage Measurement... 14:22:12 Voltage Offset Correction: v_off_ini = -21.010 uV, v_off_fin = -12.808 uV 14:22:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.401 uVs 14:22:12 Integrated Voltage Measurement... 14:22:21 Voltage Offset Correction: v_off_ini = -30.635 uV, v_off_fin = -40.139 uV 14:22:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.124 uVs 14:22:21 Integrated Voltage Measurement... 14:22:30 Voltage Offset Correction: v_off_ini = -36.548 uV, v_off_fin = -18.680 uV 14:22:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.541 uVs 14:22:30 Integrated Voltage Measurement... 14:22:39 Voltage Offset Correction: v_off_ini = -33.164 uV, v_off_fin = -42.261 uV 14:22:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.699 uVs 14:22:39 Integrated Voltage Measurement... 14:22:48 Voltage Offset Correction: v_off_ini = -31.619 uV, v_off_fin = -35.669 uV 14:22:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.450 uVs 14:22:51 I2X Average and RMS of Measurements VT = -107.538 +- 8.471 uVs I2X = 9.894 +- 0.779 uTm^2 14:22:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:22:58 Integrated Voltage Measurement... 14:23:07 Voltage Offset Correction: v_off_ini = -36.983 uV, v_off_fin = -32.749 uV 14:23:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -286.822 uVs 14:23:07 Integrated Voltage Measurement... 14:23:16 Voltage Offset Correction: v_off_ini = -23.526 uV, v_off_fin = -17.768 uV 14:23:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.820 uVs 14:23:16 Integrated Voltage Measurement... 14:23:25 Voltage Offset Correction: v_off_ini = -17.425 uV, v_off_fin = -20.638 uV 14:23:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.523 uVs 14:23:25 Integrated Voltage Measurement... 14:23:34 Voltage Offset Correction: v_off_ini = -20.086 uV, v_off_fin = -21.828 uV 14:23:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.310 uVs 14:23:34 Integrated Voltage Measurement... 14:23:43 Voltage Offset Correction: v_off_ini = -19.994 uV, v_off_fin = -22.922 uV 14:23:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.230 uVs 14:23:43 Integrated Voltage Measurement... 14:23:52 Voltage Offset Correction: v_off_ini = -31.784 uV, v_off_fin = -35.678 uV 14:23:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.379 uVs 14:23:55 I2Y Average and RMS of Measurements VT = -284.347 +- 6.769 uVs I2Y = -26.160 +- 0.623 uTm^2 14:24:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:24:10 Integrated Voltage Measurement... 14:24:19 Voltage Offset Correction: v_off_ini = -1.699 uV, v_off_fin = -12.527 uV 14:24:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -133.211 uVs 14:24:19 Integrated Voltage Measurement... 14:24:28 Voltage Offset Correction: v_off_ini = -4.436 uV, v_off_fin = -2.325 uV 14:24:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.959 uVs 14:24:28 Integrated Voltage Measurement... 14:24:37 Voltage Offset Correction: v_off_ini = -2.320 uV, v_off_fin = -9.624 uV 14:24:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.182 uVs 14:24:37 Integrated Voltage Measurement... 14:24:46 Voltage Offset Correction: v_off_ini = -4.577 uV, v_off_fin = -1.501 uV 14:24:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.417 uVs 14:24:46 Integrated Voltage Measurement... 14:24:55 Voltage Offset Correction: v_off_ini = 1.656 uV, v_off_fin = -14.814 uV 14:24:55 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -108.502 uVs 14:24:55 Integrated Voltage Measurement... 14:25:04 Voltage Offset Correction: v_off_ini = -6.100 uV, v_off_fin = -0.928 uV 14:25:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.761 uVs 14:25:08 I1X Average and RMS of Measurements VT = -109.172 +- 4.216 uVs I1X = 21.836 +- 0.844 uTm 14:25:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:25:15 Integrated Voltage Measurement... 14:25:24 Voltage Offset Correction: v_off_ini = 5.066 uV, v_off_fin = 12.124 uV 14:25:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -175.649 uVs 14:25:24 Integrated Voltage Measurement... 14:25:33 Voltage Offset Correction: v_off_ini = 14.561 uV, v_off_fin = 17.509 uV 14:25:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.515 uVs 14:25:33 Integrated Voltage Measurement... 14:25:42 Voltage Offset Correction: v_off_ini = 9.643 uV, v_off_fin = 3.688 uV 14:25:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -163.968 uVs 14:25:42 Integrated Voltage Measurement... 14:25:51 Voltage Offset Correction: v_off_ini = 16.203 uV, v_off_fin = 11.916 uV 14:25:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.013 uVs 14:25:51 Integrated Voltage Measurement... 14:26:00 Voltage Offset Correction: v_off_ini = 16.057 uV, v_off_fin = 9.672 uV 14:26:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -162.273 uVs 14:26:00 Integrated Voltage Measurement... 14:26:09 Voltage Offset Correction: v_off_ini = 20.898 uV, v_off_fin = 31.627 uV 14:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 172.337 uVs 14:26:13 I1Y Average and RMS of Measurements VT = -171.793 +- 4.883 uVs I1Y = -34.356 +- 0.977 uTm 14:26:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:26:21 Integrated Voltage Measurement... 14:26:30 Voltage Offset Correction: v_off_ini = 5.758 uV, v_off_fin = 11.038 uV 14:26:30 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -104.118 uVs 14:26:30 Integrated Voltage Measurement... 14:26:39 Voltage Offset Correction: v_off_ini = 23.812 uV, v_off_fin = 27.317 uV 14:26:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 132.952 uVs 14:26:39 Integrated Voltage Measurement... 14:26:48 Voltage Offset Correction: v_off_ini = 34.985 uV, v_off_fin = 27.878 uV 14:26:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.406 uVs 14:26:48 Integrated Voltage Measurement... 14:26:57 Voltage Offset Correction: v_off_ini = 26.834 uV, v_off_fin = 39.798 uV 14:26:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.021 uVs 14:26:57 Integrated Voltage Measurement... 14:27:06 Voltage Offset Correction: v_off_ini = 35.173 uV, v_off_fin = 31.664 uV 14:27:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.433 uVs 14:27:06 Integrated Voltage Measurement... 14:27:15 Voltage Offset Correction: v_off_ini = 50.094 uV, v_off_fin = 47.236 uV 14:27:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.484 uVs 14:27:17 I2X Average and RMS of Measurements VT = -124.902 +- 4.694 uVs I2X = 11.491 +- 0.432 uTm^2 14:27:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:27:25 Integrated Voltage Measurement... 14:27:34 Voltage Offset Correction: v_off_ini = 47.209 uV, v_off_fin = 42.961 uV 14:27:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.129 uVs 14:27:34 Integrated Voltage Measurement... 14:27:43 Voltage Offset Correction: v_off_ini = 41.543 uV, v_off_fin = 37.791 uV 14:27:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.385 uVs 14:27:43 Integrated Voltage Measurement... 14:27:52 Voltage Offset Correction: v_off_ini = 43.491 uV, v_off_fin = 36.965 uV 14:27:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.629 uVs 14:27:52 Integrated Voltage Measurement... 14:28:01 Voltage Offset Correction: v_off_ini = 45.822 uV, v_off_fin = 38.025 uV 14:28:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.982 uVs 14:28:01 Integrated Voltage Measurement... 14:28:10 Voltage Offset Correction: v_off_ini = 34.578 uV, v_off_fin = 24.586 uV 14:28:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.055 uVs 14:28:10 Integrated Voltage Measurement... 14:28:19 Voltage Offset Correction: v_off_ini = 44.552 uV, v_off_fin = 48.024 uV 14:28:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.123 uVs 14:28:22 I2Y Average and RMS of Measurements VT = -276.217 +- 5.613 uVs I2Y = -25.412 +- 0.516 uTm^2 14:28:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:37 Integrated Voltage Measurement... 14:28:46 Voltage Offset Correction: v_off_ini = 32.520 uV, v_off_fin = 37.488 uV 14:28:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.732 uVs 14:28:46 Integrated Voltage Measurement... 14:28:55 Voltage Offset Correction: v_off_ini = 34.856 uV, v_off_fin = 48.034 uV 14:28:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.210 uVs 14:28:55 Integrated Voltage Measurement... 14:29:04 Voltage Offset Correction: v_off_ini = 41.612 uV, v_off_fin = 41.715 uV 14:29:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.634 uVs 14:29:04 Integrated Voltage Measurement... 14:29:13 Voltage Offset Correction: v_off_ini = 43.791 uV, v_off_fin = 56.112 uV 14:29:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.557 uVs 14:29:13 Integrated Voltage Measurement... 14:29:22 Voltage Offset Correction: v_off_ini = 36.639 uV, v_off_fin = 40.803 uV 14:29:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.207 uVs 14:29:22 Integrated Voltage Measurement... 14:29:31 Voltage Offset Correction: v_off_ini = 48.302 uV, v_off_fin = 41.330 uV 14:29:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.105 uVs 14:29:35 I1X Average and RMS of Measurements VT = -106.907 +- 1.930 uVs I1X = 21.382 +- 0.386 uTm 14:29:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:42 Integrated Voltage Measurement... 14:29:51 Voltage Offset Correction: v_off_ini = 34.526 uV, v_off_fin = 29.814 uV 14:29:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -157.183 uVs 14:29:51 Integrated Voltage Measurement... 14:30:00 Voltage Offset Correction: v_off_ini = 27.982 uV, v_off_fin = 36.779 uV 14:30:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.491 uVs 14:30:00 Integrated Voltage Measurement... 14:30:09 Voltage Offset Correction: v_off_ini = 27.616 uV, v_off_fin = 24.219 uV 14:30:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.236 uVs 14:30:09 Integrated Voltage Measurement... 14:30:18 Voltage Offset Correction: v_off_ini = 30.597 uV, v_off_fin = 51.027 uV 14:30:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 182.983 uVs 14:30:18 Integrated Voltage Measurement... 14:30:27 Voltage Offset Correction: v_off_ini = 33.148 uV, v_off_fin = 24.844 uV 14:30:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.894 uVs 14:30:27 Integrated Voltage Measurement... 14:30:36 Voltage Offset Correction: v_off_ini = 44.094 uV, v_off_fin = 58.206 uV 14:30:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 161.877 uVs 14:30:40 I1Y Average and RMS of Measurements VT = -170.111 +- 5.661 uVs I1Y = -34.020 +- 1.131 uTm 14:30:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:48 Integrated Voltage Measurement... 14:30:57 Voltage Offset Correction: v_off_ini = 21.339 uV, v_off_fin = 12.183 uV 14:30:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -132.078 uVs 14:30:57 Integrated Voltage Measurement... 14:31:06 Voltage Offset Correction: v_off_ini = 21.320 uV, v_off_fin = 29.775 uV 14:31:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.959 uVs 14:31:06 Integrated Voltage Measurement... 14:31:15 Voltage Offset Correction: v_off_ini = 16.074 uV, v_off_fin = 3.888 uV 14:31:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.534 uVs 14:31:15 Integrated Voltage Measurement... 14:31:24 Voltage Offset Correction: v_off_ini = 32.228 uV, v_off_fin = 24.430 uV 14:31:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.019 uVs 14:31:24 Integrated Voltage Measurement... 14:31:33 Voltage Offset Correction: v_off_ini = 20.358 uV, v_off_fin = 13.910 uV 14:31:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.263 uVs 14:31:33 Integrated Voltage Measurement... 14:31:42 Voltage Offset Correction: v_off_ini = 19.112 uV, v_off_fin = 19.251 uV 14:31:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.077 uVs 14:31:44 I2X Average and RMS of Measurements VT = -128.322 +- 4.379 uVs I2X = 11.806 +- 0.403 uTm^2 14:31:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:52 Integrated Voltage Measurement... 14:32:01 Voltage Offset Correction: v_off_ini = 11.146 uV, v_off_fin = 19.529 uV 14:32:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.861 uVs 14:32:01 Integrated Voltage Measurement... 14:32:10 Voltage Offset Correction: v_off_ini = 18.015 uV, v_off_fin = 19.745 uV 14:32:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.295 uVs 14:32:10 Integrated Voltage Measurement... 14:32:19 Voltage Offset Correction: v_off_ini = 16.681 uV, v_off_fin = 25.033 uV 14:32:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.636 uVs 14:32:19 Integrated Voltage Measurement... 14:32:28 Voltage Offset Correction: v_off_ini = 21.249 uV, v_off_fin = 17.919 uV 14:32:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.279 uVs 14:32:28 Integrated Voltage Measurement... 14:32:37 Voltage Offset Correction: v_off_ini = 10.606 uV, v_off_fin = 11.512 uV 14:32:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.029 uVs 14:32:37 Integrated Voltage Measurement... 14:32:46 Voltage Offset Correction: v_off_ini = 11.420 uV, v_off_fin = 21.151 uV 14:32:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.167 uVs 14:32:49 I2Y Average and RMS of Measurements VT = -272.211 +- 4.345 uVs I2Y = -25.043 +- 0.400 uTm^2 14:32:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:33:04 Integrated Voltage Measurement... 14:33:13 Voltage Offset Correction: v_off_ini = 21.242 uV, v_off_fin = 23.140 uV 14:33:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -121.842 uVs 14:33:13 Integrated Voltage Measurement... 14:33:22 Voltage Offset Correction: v_off_ini = 31.468 uV, v_off_fin = 25.002 uV 14:33:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.068 uVs 14:33:22 Integrated Voltage Measurement... 14:33:31 Voltage Offset Correction: v_off_ini = 24.815 uV, v_off_fin = 31.626 uV 14:33:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.869 uVs 14:33:31 Integrated Voltage Measurement... 14:33:40 Voltage Offset Correction: v_off_ini = 21.550 uV, v_off_fin = 32.847 uV 14:33:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.532 uVs 14:33:40 Integrated Voltage Measurement... 14:33:49 Voltage Offset Correction: v_off_ini = 42.265 uV, v_off_fin = 27.147 uV 14:33:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.650 uVs 14:33:49 Integrated Voltage Measurement... 14:33:58 Voltage Offset Correction: v_off_ini = 27.929 uV, v_off_fin = 24.222 uV 14:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.542 uVs 14:34:02 I1X Average and RMS of Measurements VT = -118.917 +- 11.722 uVs I1X = 23.785 +- 2.344 uTm 14:34:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:34:09 Integrated Voltage Measurement... 14:34:18 Voltage Offset Correction: v_off_ini = 31.801 uV, v_off_fin = 19.575 uV 14:34:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.163 uVs 14:34:18 Integrated Voltage Measurement... 14:34:27 Voltage Offset Correction: v_off_ini = 36.855 uV, v_off_fin = 39.913 uV 14:34:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.818 uVs 14:34:27 Integrated Voltage Measurement... 14:34:36 Voltage Offset Correction: v_off_ini = 29.507 uV, v_off_fin = 20.582 uV 14:34:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.812 uVs 14:34:36 Integrated Voltage Measurement... 14:34:45 Voltage Offset Correction: v_off_ini = 28.976 uV, v_off_fin = 30.653 uV 14:34:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.352 uVs 14:34:45 Integrated Voltage Measurement... 14:34:54 Voltage Offset Correction: v_off_ini = 5.102 uV, v_off_fin = 2.444 uV 14:34:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.957 uVs 14:34:54 Integrated Voltage Measurement... 14:35:03 Voltage Offset Correction: v_off_ini = 8.441 uV, v_off_fin = 14.256 uV 14:35:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.270 uVs 14:35:07 I1Y Average and RMS of Measurements VT = -171.395 +- 4.513 uVs I1Y = -34.278 +- 0.902 uTm 14:35:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:35:15 Integrated Voltage Measurement... 14:35:24 Voltage Offset Correction: v_off_ini = -4.744 uV, v_off_fin = -13.645 uV 14:35:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.052 uVs 14:35:24 Integrated Voltage Measurement... 14:35:33 Voltage Offset Correction: v_off_ini = -3.827 uV, v_off_fin = -6.930 uV 14:35:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.312 uVs 14:35:33 Integrated Voltage Measurement... 14:35:42 Voltage Offset Correction: v_off_ini = -2.810 uV, v_off_fin = -15.630 uV 14:35:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.367 uVs 14:35:42 Integrated Voltage Measurement... 14:35:51 Voltage Offset Correction: v_off_ini = 4.076 uV, v_off_fin = 0.902 uV 14:35:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.979 uVs 14:35:51 Integrated Voltage Measurement... 14:36:00 Voltage Offset Correction: v_off_ini = -1.631 uV, v_off_fin = -8.833 uV 14:36:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.467 uVs 14:36:00 Integrated Voltage Measurement... 14:36:09 Voltage Offset Correction: v_off_ini = -9.343 uV, v_off_fin = 5.577 uV 14:36:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.056 uVs 14:36:11 I2X Average and RMS of Measurements VT = -132.206 +- 6.706 uVs I2X = 12.163 +- 0.617 uTm^2 14:36:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:36:19 Integrated Voltage Measurement... 14:36:28 Voltage Offset Correction: v_off_ini = 13.067 uV, v_off_fin = -0.985 uV 14:36:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.940 uVs 14:36:28 Integrated Voltage Measurement... 14:36:37 Voltage Offset Correction: v_off_ini = -1.673 uV, v_off_fin = 7.307 uV 14:36:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.795 uVs 14:36:37 Integrated Voltage Measurement... 14:36:46 Voltage Offset Correction: v_off_ini = 17.287 uV, v_off_fin = 3.778 uV 14:36:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.271 uVs 14:36:46 Integrated Voltage Measurement... 14:36:55 Voltage Offset Correction: v_off_ini = 5.166 uV, v_off_fin = 9.570 uV 14:36:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.544 uVs 14:36:55 Integrated Voltage Measurement... 14:37:04 Voltage Offset Correction: v_off_ini = 2.288 uV, v_off_fin = 7.911 uV 14:37:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.750 uVs 14:37:04 Integrated Voltage Measurement... 14:37:13 Voltage Offset Correction: v_off_ini = 0.395 uV, v_off_fin = 5.686 uV 14:37:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.144 uVs 14:37:16 I2Y Average and RMS of Measurements VT = -264.407 +- 5.068 uVs I2Y = -24.325 +- 0.466 uTm^2 14:37:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:37:31 Integrated Voltage Measurement... 14:37:40 Voltage Offset Correction: v_off_ini = 10.738 uV, v_off_fin = 17.883 uV 14:37:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -132.010 uVs 14:37:40 Integrated Voltage Measurement... 14:37:49 Voltage Offset Correction: v_off_ini = -2.114 uV, v_off_fin = 13.794 uV 14:37:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.253 uVs 14:37:49 Integrated Voltage Measurement... 14:37:58 Voltage Offset Correction: v_off_ini = 9.987 uV, v_off_fin = 0.915 uV 14:37:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.733 uVs 14:37:58 Integrated Voltage Measurement... 14:38:07 Voltage Offset Correction: v_off_ini = 13.394 uV, v_off_fin = -0.131 uV 14:38:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.293 uVs 14:38:07 Integrated Voltage Measurement... 14:38:16 Voltage Offset Correction: v_off_ini = 1.527 uV, v_off_fin = 7.711 uV 14:38:16 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -130.027 uVs 14:38:16 Integrated Voltage Measurement... 14:38:25 Voltage Offset Correction: v_off_ini = 12.266 uV, v_off_fin = 17.318 uV 14:38:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.575 uVs 14:38:29 I1X Average and RMS of Measurements VT = -114.982 +- 5.564 uVs I1X = 22.999 +- 1.114 uTm 14:38:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:38:36 Integrated Voltage Measurement... 14:38:45 Voltage Offset Correction: v_off_ini = 4.414 uV, v_off_fin = 0.463 uV 14:38:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.654 uVs 14:38:45 Integrated Voltage Measurement... 14:38:54 Voltage Offset Correction: v_off_ini = 5.756 uV, v_off_fin = 17.255 uV 14:38:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.002 uVs 14:38:54 Integrated Voltage Measurement... 14:39:03 Voltage Offset Correction: v_off_ini = 5.548 uV, v_off_fin = -2.713 uV 14:39:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.151 uVs 14:39:03 Integrated Voltage Measurement... 14:39:12 Voltage Offset Correction: v_off_ini = 4.738 uV, v_off_fin = 9.460 uV 14:39:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.959 uVs 14:39:12 Integrated Voltage Measurement... 14:39:21 Voltage Offset Correction: v_off_ini = 1.588 uV, v_off_fin = -7.111 uV 14:39:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.773 uVs 14:39:21 Integrated Voltage Measurement... 14:39:30 Voltage Offset Correction: v_off_ini = 3.696 uV, v_off_fin = 20.998 uV 14:39:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 173.982 uVs 14:39:34 I1Y Average and RMS of Measurements VT = -173.420 +- 4.540 uVs I1Y = -34.683 +- 0.907 uTm 14:39:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:39:42 Integrated Voltage Measurement... 14:39:51 Voltage Offset Correction: v_off_ini = 4.403 uV, v_off_fin = -5.351 uV 14:39:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -127.640 uVs 14:39:51 Integrated Voltage Measurement... 14:40:00 Voltage Offset Correction: v_off_ini = -6.636 uV, v_off_fin = 5.825 uV 14:40:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 133.298 uVs 14:40:00 Integrated Voltage Measurement... 14:40:09 Voltage Offset Correction: v_off_ini = -0.797 uV, v_off_fin = -2.331 uV 14:40:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.416 uVs 14:40:09 Integrated Voltage Measurement... 14:40:18 Voltage Offset Correction: v_off_ini = -3.593 uV, v_off_fin = 5.420 uV 14:40:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 153.976 uVs 14:40:18 Integrated Voltage Measurement... 14:40:27 Voltage Offset Correction: v_off_ini = -10.089 uV, v_off_fin = -13.143 uV 14:40:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.950 uVs 14:40:27 Integrated Voltage Measurement... 14:40:36 Voltage Offset Correction: v_off_ini = -10.360 uV, v_off_fin = 6.168 uV 14:40:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.610 uVs 14:40:38 I2X Average and RMS of Measurements VT = -130.482 +- 4.661 uVs I2X = 12.005 +- 0.429 uTm^2 14:40:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:46 Integrated Voltage Measurement... 14:40:55 Voltage Offset Correction: v_off_ini = 5.525 uV, v_off_fin = -18.607 uV 14:40:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.930 uVs 14:40:55 Integrated Voltage Measurement... 14:41:04 Voltage Offset Correction: v_off_ini = 0.025 uV, v_off_fin = -2.012 uV 14:41:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.958 uVs 14:41:04 Integrated Voltage Measurement... 14:41:13 Voltage Offset Correction: v_off_ini = 0.011 uV, v_off_fin = -1.977 uV 14:41:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.838 uVs 14:41:13 Integrated Voltage Measurement... 14:41:22 Voltage Offset Correction: v_off_ini = 1.248 uV, v_off_fin = 0.641 uV 14:41:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.584 uVs 14:41:22 Integrated Voltage Measurement... 14:41:31 Voltage Offset Correction: v_off_ini = -1.186 uV, v_off_fin = -1.109 uV 14:41:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.853 uVs 14:41:31 Integrated Voltage Measurement... 14:41:40 Voltage Offset Correction: v_off_ini = -3.432 uV, v_off_fin = 10.086 uV 14:41:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.509 uVs 14:41:43 I2Y Average and RMS of Measurements VT = -265.445 +- 12.508 uVs I2Y = -24.421 +- 1.151 uTm^2 14:41:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:59 Integrated Voltage Measurement... 14:42:08 Voltage Offset Correction: v_off_ini = 6.838 uV, v_off_fin = -5.200 uV 14:42:08 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -120.435 uVs 14:42:08 Integrated Voltage Measurement... 14:42:17 Voltage Offset Correction: v_off_ini = 7.105 uV, v_off_fin = 4.810 uV 14:42:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.848 uVs 14:42:17 Integrated Voltage Measurement... 14:42:26 Voltage Offset Correction: v_off_ini = -14.607 uV, v_off_fin = -1.717 uV 14:42:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.941 uVs 14:42:26 Integrated Voltage Measurement... 14:42:35 Voltage Offset Correction: v_off_ini = -1.878 uV, v_off_fin = -1.566 uV 14:42:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.322 uVs 14:42:35 Integrated Voltage Measurement... 14:42:44 Voltage Offset Correction: v_off_ini = 1.214 uV, v_off_fin = 7.623 uV 14:42:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.694 uVs 14:42:44 Integrated Voltage Measurement... 14:42:53 Voltage Offset Correction: v_off_ini = 8.741 uV, v_off_fin = 11.622 uV 14:42:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.283 uVs 14:42:57 I1X Average and RMS of Measurements VT = -119.587 +- 1.540 uVs I1X = 23.919 +- 0.309 uTm 14:42:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:04 Integrated Voltage Measurement... 14:43:13 Voltage Offset Correction: v_off_ini = -1.440 uV, v_off_fin = -9.344 uV 14:43:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.702 uVs 14:43:13 Integrated Voltage Measurement... 14:43:22 Voltage Offset Correction: v_off_ini = 1.840 uV, v_off_fin = 16.663 uV 14:43:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.275 uVs 14:43:22 Integrated Voltage Measurement... 14:43:31 Voltage Offset Correction: v_off_ini = 11.979 uV, v_off_fin = 7.175 uV 14:43:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.536 uVs 14:43:31 Integrated Voltage Measurement... 14:43:40 Voltage Offset Correction: v_off_ini = 15.525 uV, v_off_fin = 18.429 uV 14:43:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 141.633 uVs 14:43:40 Integrated Voltage Measurement... 14:43:48 Voltage Offset Correction: v_off_ini = 3.316 uV, v_off_fin = 2.625 uV 14:43:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -171.783 uVs 14:43:49 Integrated Voltage Measurement... 14:43:57 Voltage Offset Correction: v_off_ini = 0.945 uV, v_off_fin = 14.207 uV 14:43:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.372 uVs 14:44:02 I1Y Average and RMS of Measurements VT = -167.217 +- 8.915 uVs I1Y = -33.442 +- 1.783 uTm 14:44:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:44:09 Integrated Voltage Measurement... 14:44:18 Voltage Offset Correction: v_off_ini = -2.987 uV, v_off_fin = -11.741 uV 14:44:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -118.101 uVs 14:44:18 Integrated Voltage Measurement... 14:44:27 Voltage Offset Correction: v_off_ini = 8.981 uV, v_off_fin = -1.904 uV 14:44:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 145.659 uVs 14:44:27 Integrated Voltage Measurement... 14:44:36 Voltage Offset Correction: v_off_ini = 11.217 uV, v_off_fin = -1.221 uV 14:44:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -139.160 uVs 14:44:36 Integrated Voltage Measurement... 14:44:45 Voltage Offset Correction: v_off_ini = 6.331 uV, v_off_fin = 17.664 uV 14:44:45 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 127.317 uVs 14:44:46 Integrated Voltage Measurement... 14:44:54 Voltage Offset Correction: v_off_ini = 2.723 uV, v_off_fin = -15.686 uV 14:44:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.979 uVs 14:44:55 Integrated Voltage Measurement... 14:45:03 Voltage Offset Correction: v_off_ini = 2.842 uV, v_off_fin = 20.305 uV 14:45:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.789 uVs 14:45:06 I2X Average and RMS of Measurements VT = -131.168 +- 2.045 uVs I2X = 12.068 +- 0.188 uTm^2 14:45:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:14 Integrated Voltage Measurement... 14:45:23 Voltage Offset Correction: v_off_ini = 6.106 uV, v_off_fin = 5.621 uV 14:45:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.168 uVs 14:45:23 Integrated Voltage Measurement... 14:45:32 Voltage Offset Correction: v_off_ini = -3.627 uV, v_off_fin = 9.054 uV 14:45:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.693 uVs 14:45:32 Integrated Voltage Measurement... 14:45:41 Voltage Offset Correction: v_off_ini = 0.521 uV, v_off_fin = 0.580 uV 14:45:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.470 uVs 14:45:41 Integrated Voltage Measurement... 14:45:50 Voltage Offset Correction: v_off_ini = -8.027 uV, v_off_fin = 0.560 uV 14:45:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.775 uVs 14:45:50 Integrated Voltage Measurement... 14:45:59 Voltage Offset Correction: v_off_ini = 10.498 uV, v_off_fin = 1.152 uV 14:45:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.826 uVs 14:45:59 Integrated Voltage Measurement... 14:46:08 Voltage Offset Correction: v_off_ini = 10.970 uV, v_off_fin = 8.837 uV 14:46:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.390 uVs 14:46:10 I2Y Average and RMS of Measurements VT = -262.387 +- 3.783 uVs I2Y = -24.140 +- 0.348 uTm^2 14:46:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:46:26 Integrated Voltage Measurement... 14:46:35 Voltage Offset Correction: v_off_ini = -3.825 uV, v_off_fin = -8.534 uV 14:46:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -123.278 uVs 14:46:35 Integrated Voltage Measurement... 14:46:44 Voltage Offset Correction: v_off_ini = -1.968 uV, v_off_fin = 3.634 uV 14:46:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.187 uVs 14:46:44 Integrated Voltage Measurement... 14:46:53 Voltage Offset Correction: v_off_ini = 10.841 uV, v_off_fin = 7.956 uV 14:46:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.955 uVs 14:46:53 Integrated Voltage Measurement... 14:47:02 Voltage Offset Correction: v_off_ini = 1.951 uV, v_off_fin = 9.179 uV 14:47:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.592 uVs 14:47:02 Integrated Voltage Measurement... 14:47:11 Voltage Offset Correction: v_off_ini = -0.485 uV, v_off_fin = 4.876 uV 14:47:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.252 uVs 14:47:11 Integrated Voltage Measurement... 14:47:20 Voltage Offset Correction: v_off_ini = 15.406 uV, v_off_fin = 10.635 uV 14:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.641 uVs 14:47:24 I1X Average and RMS of Measurements VT = -124.484 +- 4.068 uVs I1X = 24.898 +- 0.814 uTm 14:47:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:47:31 Integrated Voltage Measurement... 14:47:40 Voltage Offset Correction: v_off_ini = 6.704 uV, v_off_fin = -5.990 uV 14:47:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.141 uVs 14:47:40 Integrated Voltage Measurement... 14:47:49 Voltage Offset Correction: v_off_ini = 5.918 uV, v_off_fin = 19.342 uV 14:47:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 167.867 uVs 14:47:49 Integrated Voltage Measurement... 14:47:58 Voltage Offset Correction: v_off_ini = 15.670 uV, v_off_fin = 4.013 uV 14:47:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.669 uVs 14:47:58 Integrated Voltage Measurement... 14:48:07 Voltage Offset Correction: v_off_ini = 20.893 uV, v_off_fin = 19.795 uV 14:48:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.331 uVs 14:48:07 Integrated Voltage Measurement... 14:48:16 Voltage Offset Correction: v_off_ini = 3.990 uV, v_off_fin = -9.814 uV 14:48:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -165.791 uVs 14:48:16 Integrated Voltage Measurement... 14:48:25 Voltage Offset Correction: v_off_ini = 10.424 uV, v_off_fin = 29.376 uV 14:48:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.703 uVs 14:48:29 I1Y Average and RMS of Measurements VT = -172.584 +- 3.240 uVs I1Y = -34.515 +- 0.648 uTm 14:48:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:48:37 Integrated Voltage Measurement... 14:48:46 Voltage Offset Correction: v_off_ini = 9.621 uV, v_off_fin = 13.239 uV 14:48:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -120.802 uVs 14:48:46 Integrated Voltage Measurement... 14:48:55 Voltage Offset Correction: v_off_ini = 12.456 uV, v_off_fin = 31.681 uV 14:48:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.337 uVs 14:48:55 Integrated Voltage Measurement... 14:49:04 Voltage Offset Correction: v_off_ini = 17.789 uV, v_off_fin = 12.613 uV 14:49:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.393 uVs 14:49:04 Integrated Voltage Measurement... 14:49:13 Voltage Offset Correction: v_off_ini = 26.334 uV, v_off_fin = 31.027 uV 14:49:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.342 uVs 14:49:13 Integrated Voltage Measurement... 14:49:22 Voltage Offset Correction: v_off_ini = 20.837 uV, v_off_fin = 17.795 uV 14:49:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.822 uVs 14:49:22 Integrated Voltage Measurement... 14:49:31 Voltage Offset Correction: v_off_ini = 5.027 uV, v_off_fin = 22.562 uV 14:49:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 167.055 uVs 14:49:33 I2X Average and RMS of Measurements VT = -131.792 +- 7.779 uVs I2X = 12.125 +- 0.715 uTm^2 14:49:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:41 Integrated Voltage Measurement... 14:49:50 Voltage Offset Correction: v_off_ini = 15.095 uV, v_off_fin = 17.397 uV 14:49:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.898 uVs 14:49:50 Integrated Voltage Measurement... 14:49:59 Voltage Offset Correction: v_off_ini = 23.024 uV, v_off_fin = 18.204 uV 14:49:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.106 uVs 14:49:59 Integrated Voltage Measurement... 14:50:08 Voltage Offset Correction: v_off_ini = 14.323 uV, v_off_fin = 11.614 uV 14:50:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.058 uVs 14:50:08 Integrated Voltage Measurement... 14:50:17 Voltage Offset Correction: v_off_ini = 13.081 uV, v_off_fin = 15.504 uV 14:50:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.522 uVs 14:50:17 Integrated Voltage Measurement... 14:50:26 Voltage Offset Correction: v_off_ini = 16.626 uV, v_off_fin = 17.072 uV 14:50:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.725 uVs 14:50:26 Integrated Voltage Measurement... 14:50:35 Voltage Offset Correction: v_off_ini = 28.957 uV, v_off_fin = 18.817 uV 14:50:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.976 uVs 14:50:38 I2Y Average and RMS of Measurements VT = -247.381 +- 2.989 uVs I2Y = -22.759 +- 0.275 uTm^2 14:50:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:56 Integrated Voltage Measurement... 14:51:05 Voltage Offset Correction: v_off_ini = 21.887 uV, v_off_fin = 17.782 uV 14:51:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.845 uVs 14:51:05 Integrated Voltage Measurement... 14:51:14 Voltage Offset Correction: v_off_ini = 18.601 uV, v_off_fin = 24.853 uV 14:51:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.724 uVs 14:51:14 Integrated Voltage Measurement... 14:51:23 Voltage Offset Correction: v_off_ini = 22.801 uV, v_off_fin = 28.593 uV 14:51:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.190 uVs 14:51:23 Integrated Voltage Measurement... 14:51:32 Voltage Offset Correction: v_off_ini = 36.559 uV, v_off_fin = 38.353 uV 14:51:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.677 uVs 14:51:32 Integrated Voltage Measurement... 14:51:41 Voltage Offset Correction: v_off_ini = 28.829 uV, v_off_fin = 27.788 uV 14:51:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.013 uVs 14:51:41 Integrated Voltage Measurement... 14:51:50 Voltage Offset Correction: v_off_ini = 39.313 uV, v_off_fin = 40.606 uV 14:51:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.542 uVs 14:51:54 I1X Average and RMS of Measurements VT = -120.832 +- 12.059 uVs I1X = 24.167 +- 2.412 uTm 14:51:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:01 Integrated Voltage Measurement... 14:52:10 Voltage Offset Correction: v_off_ini = 36.641 uV, v_off_fin = 23.489 uV 14:52:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -167.190 uVs 14:52:10 Integrated Voltage Measurement... 14:52:19 Voltage Offset Correction: v_off_ini = 38.641 uV, v_off_fin = 60.896 uV 14:52:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.713 uVs 14:52:19 Integrated Voltage Measurement... 14:52:28 Voltage Offset Correction: v_off_ini = 42.323 uV, v_off_fin = 32.145 uV 14:52:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -176.449 uVs 14:52:28 Integrated Voltage Measurement... 14:52:37 Voltage Offset Correction: v_off_ini = 56.720 uV, v_off_fin = 68.873 uV 14:52:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.450 uVs 14:52:37 Integrated Voltage Measurement... 14:52:46 Voltage Offset Correction: v_off_ini = 61.741 uV, v_off_fin = 43.155 uV 14:52:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -169.148 uVs 14:52:46 Integrated Voltage Measurement... 14:52:55 Voltage Offset Correction: v_off_ini = 44.347 uV, v_off_fin = 57.809 uV 14:52:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 184.885 uVs 14:52:59 I1Y Average and RMS of Measurements VT = -172.472 +- 5.036 uVs I1Y = -34.492 +- 1.007 uTm 14:53:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:07 Integrated Voltage Measurement... 14:53:16 Voltage Offset Correction: v_off_ini = 40.332 uV, v_off_fin = 16.501 uV 14:53:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -114.374 uVs 14:53:16 Integrated Voltage Measurement... 14:53:25 Voltage Offset Correction: v_off_ini = 43.413 uV, v_off_fin = 44.052 uV 14:53:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 150.801 uVs 14:53:25 Integrated Voltage Measurement... 14:53:34 Voltage Offset Correction: v_off_ini = 41.322 uV, v_off_fin = 21.954 uV 14:53:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -138.105 uVs 14:53:34 Integrated Voltage Measurement... 14:53:43 Voltage Offset Correction: v_off_ini = 22.755 uV, v_off_fin = 29.352 uV 14:53:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 138.804 uVs 14:53:43 Integrated Voltage Measurement... 14:53:52 Voltage Offset Correction: v_off_ini = 28.222 uV, v_off_fin = 39.817 uV 14:53:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.054 uVs 14:53:52 Integrated Voltage Measurement... 14:54:01 Voltage Offset Correction: v_off_ini = 42.303 uV, v_off_fin = 44.056 uV 14:54:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.866 uVs 14:54:04 I2X Average and RMS of Measurements VT = -138.667 +- 5.053 uVs I2X = 12.758 +- 0.465 uTm^2 14:54:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:54:11 Integrated Voltage Measurement... 14:54:20 Voltage Offset Correction: v_off_ini = 35.229 uV, v_off_fin = 43.946 uV 14:54:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.744 uVs 14:54:20 Integrated Voltage Measurement... 14:54:29 Voltage Offset Correction: v_off_ini = 41.949 uV, v_off_fin = 44.722 uV 14:54:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.485 uVs 14:54:29 Integrated Voltage Measurement... 14:54:38 Voltage Offset Correction: v_off_ini = 52.793 uV, v_off_fin = 58.371 uV 14:54:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.216 uVs 14:54:38 Integrated Voltage Measurement... 14:54:47 Voltage Offset Correction: v_off_ini = 60.763 uV, v_off_fin = 53.730 uV 14:54:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.302 uVs 14:54:47 Integrated Voltage Measurement... 14:54:56 Voltage Offset Correction: v_off_ini = 60.067 uV, v_off_fin = 48.955 uV 14:54:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.464 uVs 14:54:56 Integrated Voltage Measurement... 14:55:05 Voltage Offset Correction: v_off_ini = 45.954 uV, v_off_fin = 58.964 uV 14:55:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.100 uVs 14:55:08 I2Y Average and RMS of Measurements VT = -251.385 +- 6.472 uVs I2Y = -23.127 +- 0.595 uTm^2 14:55:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:55:26 Integrated Voltage Measurement... 14:55:35 Voltage Offset Correction: v_off_ini = 57.761 uV, v_off_fin = 59.051 uV 14:55:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.288 uVs 14:55:35 Integrated Voltage Measurement... 14:55:44 Voltage Offset Correction: v_off_ini = 47.865 uV, v_off_fin = 42.453 uV 14:55:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.964 uVs 14:55:44 Integrated Voltage Measurement... 14:55:53 Voltage Offset Correction: v_off_ini = 37.631 uV, v_off_fin = 50.183 uV 14:55:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.458 uVs 14:55:53 Integrated Voltage Measurement... 14:56:02 Voltage Offset Correction: v_off_ini = 62.873 uV, v_off_fin = 50.266 uV 14:56:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.000 uVs 14:56:02 Integrated Voltage Measurement... 14:56:11 Voltage Offset Correction: v_off_ini = 51.225 uV, v_off_fin = 52.288 uV 14:56:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.406 uVs 14:56:11 Integrated Voltage Measurement... 14:56:20 Voltage Offset Correction: v_off_ini = 43.838 uV, v_off_fin = 41.727 uV 14:56:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.011 uVs 14:56:25 I1X Average and RMS of Measurements VT = -114.854 +- 13.104 uVs I1X = 22.971 +- 2.621 uTm 14:56:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:56:31 Integrated Voltage Measurement... 14:56:40 Voltage Offset Correction: v_off_ini = 31.984 uV, v_off_fin = 31.500 uV 14:56:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -169.140 uVs 14:56:40 Integrated Voltage Measurement... 14:56:49 Voltage Offset Correction: v_off_ini = 41.197 uV, v_off_fin = 57.233 uV 14:56:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 175.812 uVs 14:56:49 Integrated Voltage Measurement... 14:56:58 Voltage Offset Correction: v_off_ini = 58.871 uV, v_off_fin = 37.298 uV 14:56:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.368 uVs 14:56:58 Integrated Voltage Measurement... 14:57:07 Voltage Offset Correction: v_off_ini = 35.005 uV, v_off_fin = 47.288 uV 14:57:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.533 uVs 14:57:07 Integrated Voltage Measurement... 14:57:16 Voltage Offset Correction: v_off_ini = 45.190 uV, v_off_fin = 19.363 uV 14:57:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.362 uVs 14:57:16 Integrated Voltage Measurement... 14:57:25 Voltage Offset Correction: v_off_ini = 43.758 uV, v_off_fin = 39.978 uV 14:57:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.687 uVs 14:57:30 I1Y Average and RMS of Measurements VT = -172.650 +- 5.543 uVs I1Y = -34.528 +- 1.109 uTm 14:57:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:57:37 Integrated Voltage Measurement... 14:57:46 Voltage Offset Correction: v_off_ini = 35.067 uV, v_off_fin = 32.804 uV 14:57:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -124.404 uVs 14:57:46 Integrated Voltage Measurement... 14:57:55 Voltage Offset Correction: v_off_ini = 39.460 uV, v_off_fin = 31.435 uV 14:57:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.076 uVs 14:57:55 Integrated Voltage Measurement... 14:58:04 Voltage Offset Correction: v_off_ini = 41.892 uV, v_off_fin = 26.741 uV 14:58:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -122.566 uVs 14:58:04 Integrated Voltage Measurement... 14:58:13 Voltage Offset Correction: v_off_ini = 33.045 uV, v_off_fin = 67.550 uV 14:58:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 122.096 uVs 14:58:13 Integrated Voltage Measurement... 14:58:22 Voltage Offset Correction: v_off_ini = 54.474 uV, v_off_fin = 50.192 uV 14:58:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.754 uVs 14:58:22 Integrated Voltage Measurement... 14:58:31 Voltage Offset Correction: v_off_ini = 67.040 uV, v_off_fin = 55.750 uV 14:58:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.530 uVs 14:58:34 I2X Average and RMS of Measurements VT = -130.237 +- 5.603 uVs I2X = 11.982 +- 0.515 uTm^2 14:58:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:58:42 Integrated Voltage Measurement... 14:58:51 Voltage Offset Correction: v_off_ini = 52.687 uV, v_off_fin = 44.812 uV 14:58:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.307 uVs 14:58:51 Integrated Voltage Measurement... 14:59:00 Voltage Offset Correction: v_off_ini = 44.690 uV, v_off_fin = 45.980 uV 14:59:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.052 uVs 14:59:00 Integrated Voltage Measurement... 14:59:09 Voltage Offset Correction: v_off_ini = 37.412 uV, v_off_fin = 35.450 uV 14:59:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.198 uVs 14:59:09 Integrated Voltage Measurement... 14:59:18 Voltage Offset Correction: v_off_ini = 37.484 uV, v_off_fin = 49.407 uV 14:59:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.347 uVs 14:59:18 Integrated Voltage Measurement... 14:59:27 Voltage Offset Correction: v_off_ini = 46.394 uV, v_off_fin = 44.696 uV 14:59:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.443 uVs 14:59:27 Integrated Voltage Measurement... 14:59:36 Voltage Offset Correction: v_off_ini = 51.932 uV, v_off_fin = 47.559 uV 14:59:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.313 uVs 14:59:38 I2Y Average and RMS of Measurements VT = -234.777 +- 2.890 uVs I2Y = -21.599 +- 0.266 uTm^2 14:59:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:59:57 Integrated Voltage Measurement... 15:00:06 Voltage Offset Correction: v_off_ini = 43.071 uV, v_off_fin = 42.285 uV 15:00:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -115.149 uVs 15:00:06 Integrated Voltage Measurement... 15:00:15 Voltage Offset Correction: v_off_ini = 49.632 uV, v_off_fin = 38.396 uV 15:00:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.717 uVs 15:00:15 Integrated Voltage Measurement... 15:00:24 Voltage Offset Correction: v_off_ini = 47.546 uV, v_off_fin = 37.079 uV 15:00:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.653 uVs 15:00:24 Integrated Voltage Measurement... 15:00:33 Voltage Offset Correction: v_off_ini = 49.850 uV, v_off_fin = 40.660 uV 15:00:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 88.499 uVs 15:00:33 Integrated Voltage Measurement... 15:00:42 Voltage Offset Correction: v_off_ini = 32.756 uV, v_off_fin = 33.921 uV 15:00:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.102 uVs 15:00:42 Integrated Voltage Measurement... 15:00:51 Voltage Offset Correction: v_off_ini = 42.123 uV, v_off_fin = 48.024 uV 15:00:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.992 uVs 15:00:55 I1X Average and RMS of Measurements VT = -105.019 +- 4.390 uVs I1X = 21.005 +- 0.878 uTm 15:00:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:02 Integrated Voltage Measurement... 15:01:11 Voltage Offset Correction: v_off_ini = 43.869 uV, v_off_fin = 34.749 uV 15:01:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -162.678 uVs 15:01:11 Integrated Voltage Measurement... 15:01:20 Voltage Offset Correction: v_off_ini = 41.124 uV, v_off_fin = 51.977 uV 15:01:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.489 uVs 15:01:20 Integrated Voltage Measurement... 15:01:29 Voltage Offset Correction: v_off_ini = 39.586 uV, v_off_fin = 39.775 uV 15:01:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -177.144 uVs 15:01:29 Integrated Voltage Measurement... 15:01:38 Voltage Offset Correction: v_off_ini = 61.561 uV, v_off_fin = 64.358 uV 15:01:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.439 uVs 15:01:38 Integrated Voltage Measurement... 15:01:47 Voltage Offset Correction: v_off_ini = 55.356 uV, v_off_fin = 36.884 uV 15:01:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.546 uVs 15:01:47 Integrated Voltage Measurement... 15:01:56 Voltage Offset Correction: v_off_ini = 63.184 uV, v_off_fin = 59.603 uV 15:01:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.387 uVs 15:02:00 I1Y Average and RMS of Measurements VT = -181.614 +- 5.669 uVs I1Y = -36.321 +- 1.134 uTm 15:02:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 44.861 uV, v_off_fin = 31.693 uV 15:02:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.058 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 56.079 uV, v_off_fin = 51.314 uV 15:02:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.085 uVs 15:02:26 Integrated Voltage Measurement... 15:02:35 Voltage Offset Correction: v_off_ini = 72.307 uV, v_off_fin = 48.582 uV 15:02:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.968 uVs 15:02:35 Integrated Voltage Measurement... 15:02:44 Voltage Offset Correction: v_off_ini = 48.557 uV, v_off_fin = 57.720 uV 15:02:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.377 uVs 15:02:44 Integrated Voltage Measurement... 15:02:53 Voltage Offset Correction: v_off_ini = 52.825 uV, v_off_fin = 40.780 uV 15:02:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -118.317 uVs 15:02:53 Integrated Voltage Measurement... 15:03:02 Voltage Offset Correction: v_off_ini = 45.188 uV, v_off_fin = 57.284 uV 15:03:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.987 uVs 15:03:04 I2X Average and RMS of Measurements VT = -128.632 +- 7.261 uVs I2X = 11.835 +- 0.668 uTm^2 15:03:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:12 Integrated Voltage Measurement... 15:03:21 Voltage Offset Correction: v_off_ini = 66.812 uV, v_off_fin = 65.979 uV 15:03:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.317 uVs 15:03:21 Integrated Voltage Measurement... 15:03:30 Voltage Offset Correction: v_off_ini = 49.868 uV, v_off_fin = 44.444 uV 15:03:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.142 uVs 15:03:30 Integrated Voltage Measurement... 15:03:39 Voltage Offset Correction: v_off_ini = 54.192 uV, v_off_fin = 63.050 uV 15:03:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.786 uVs 15:03:39 Integrated Voltage Measurement... 15:03:48 Voltage Offset Correction: v_off_ini = 61.129 uV, v_off_fin = 65.792 uV 15:03:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.165 uVs 15:03:48 Integrated Voltage Measurement... 15:03:57 Voltage Offset Correction: v_off_ini = 70.045 uV, v_off_fin = 75.146 uV 15:03:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.228 uVs 15:03:57 Integrated Voltage Measurement... 15:04:06 Voltage Offset Correction: v_off_ini = 67.493 uV, v_off_fin = 73.258 uV 15:04:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.595 uVs 15:04:09 I2Y Average and RMS of Measurements VT = -247.039 +- 5.751 uVs I2Y = -22.728 +- 0.529 uTm^2 15:04:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:27 Integrated Voltage Measurement... 15:04:36 Voltage Offset Correction: v_off_ini = 73.982 uV, v_off_fin = 67.988 uV 15:04:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.168 uVs 15:04:36 Integrated Voltage Measurement... 15:04:45 Voltage Offset Correction: v_off_ini = 86.181 uV, v_off_fin = 69.253 uV 15:04:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.051 uVs 15:04:45 Integrated Voltage Measurement... 15:04:54 Voltage Offset Correction: v_off_ini = 69.340 uV, v_off_fin = 75.597 uV 15:04:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.864 uVs 15:04:54 Integrated Voltage Measurement... 15:05:03 Voltage Offset Correction: v_off_ini = 97.760 uV, v_off_fin = 83.965 uV 15:05:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.058 uVs 15:05:03 Integrated Voltage Measurement... 15:05:12 Voltage Offset Correction: v_off_ini = 80.168 uV, v_off_fin = 70.343 uV 15:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.279 uVs 15:05:12 Integrated Voltage Measurement... 15:05:21 Voltage Offset Correction: v_off_ini = 85.752 uV, v_off_fin = 98.504 uV 15:05:21 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.496 uVs 15:05:25 I1X Average and RMS of Measurements VT = -104.653 +- 15.486 uVs I1X = 20.931 +- 3.098 uTm 15:05:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:32 Integrated Voltage Measurement... 15:05:41 Voltage Offset Correction: v_off_ini = 84.669 uV, v_off_fin = 72.946 uV 15:05:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.093 uVs 15:05:41 Integrated Voltage Measurement... 15:05:50 Voltage Offset Correction: v_off_ini = 87.630 uV, v_off_fin = 97.608 uV 15:05:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.559 uVs 15:05:50 Integrated Voltage Measurement... 15:05:59 Voltage Offset Correction: v_off_ini = 97.677 uV, v_off_fin = 76.441 uV 15:05:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -191.218 uVs 15:05:59 Integrated Voltage Measurement... 15:06:08 Voltage Offset Correction: v_off_ini = 78.065 uV, v_off_fin = 90.756 uV 15:06:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.858 uVs 15:06:08 Integrated Voltage Measurement... 15:06:17 Voltage Offset Correction: v_off_ini = 82.834 uV, v_off_fin = 82.664 uV 15:06:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -192.541 uVs 15:06:17 Integrated Voltage Measurement... 15:06:26 Voltage Offset Correction: v_off_ini = 99.771 uV, v_off_fin = 105.912 uV 15:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.468 uVs 15:06:30 I1Y Average and RMS of Measurements VT = -194.290 +- 6.901 uVs I1Y = -38.855 +- 1.380 uTm 15:06:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:06:38 Integrated Voltage Measurement... 15:06:47 Voltage Offset Correction: v_off_ini = 84.958 uV, v_off_fin = 69.541 uV 15:06:47 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -106.904 uVs 15:06:47 Integrated Voltage Measurement... 15:06:56 Voltage Offset Correction: v_off_ini = 75.637 uV, v_off_fin = 87.370 uV 15:06:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.607 uVs 15:06:56 Integrated Voltage Measurement... 15:07:05 Voltage Offset Correction: v_off_ini = 77.182 uV, v_off_fin = 75.869 uV 15:07:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.260 uVs 15:07:05 Integrated Voltage Measurement... 15:07:14 Voltage Offset Correction: v_off_ini = 86.224 uV, v_off_fin = 74.984 uV 15:07:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.106 uVs 15:07:14 Integrated Voltage Measurement... 15:07:23 Voltage Offset Correction: v_off_ini = 65.420 uV, v_off_fin = 55.102 uV 15:07:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -125.772 uVs 15:07:23 Integrated Voltage Measurement... 15:07:32 Voltage Offset Correction: v_off_ini = 66.880 uV, v_off_fin = 78.977 uV 15:07:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.396 uVs 15:07:34 I2X Average and RMS of Measurements VT = -114.341 +- 6.276 uVs I2X = 10.520 +- 0.577 uTm^2 15:07:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:42 Integrated Voltage Measurement... 15:07:51 Voltage Offset Correction: v_off_ini = 59.328 uV, v_off_fin = 64.927 uV 15:07:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.410 uVs 15:07:51 Integrated Voltage Measurement... 15:08:00 Voltage Offset Correction: v_off_ini = 65.676 uV, v_off_fin = 73.249 uV 15:08:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.989 uVs 15:08:00 Integrated Voltage Measurement... 15:08:09 Voltage Offset Correction: v_off_ini = 71.098 uV, v_off_fin = 69.747 uV 15:08:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.616 uVs 15:08:09 Integrated Voltage Measurement... 15:08:18 Voltage Offset Correction: v_off_ini = 74.220 uV, v_off_fin = 63.411 uV 15:08:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.024 uVs 15:08:18 Integrated Voltage Measurement... 15:08:27 Voltage Offset Correction: v_off_ini = 73.308 uV, v_off_fin = 67.226 uV 15:08:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.224 uVs 15:08:27 Integrated Voltage Measurement... 15:08:36 Voltage Offset Correction: v_off_ini = 78.018 uV, v_off_fin = 73.638 uV 15:08:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.374 uVs 15:08:39 I2Y Average and RMS of Measurements VT = -241.940 +- 6.043 uVs I2Y = -22.258 +- 0.556 uTm^2 15:08:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:08:57 Integrated Voltage Measurement... 15:09:06 Voltage Offset Correction: v_off_ini = 66.596 uV, v_off_fin = 67.605 uV 15:09:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.220 uVs 15:09:06 Integrated Voltage Measurement... 15:09:15 Voltage Offset Correction: v_off_ini = 64.249 uV, v_off_fin = 64.914 uV 15:09:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.609 uVs 15:09:15 Integrated Voltage Measurement... 15:09:24 Voltage Offset Correction: v_off_ini = 73.483 uV, v_off_fin = 71.638 uV 15:09:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.080 uVs 15:09:24 Integrated Voltage Measurement... 15:09:33 Voltage Offset Correction: v_off_ini = 75.704 uV, v_off_fin = 70.493 uV 15:09:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.482 uVs 15:09:33 Integrated Voltage Measurement... 15:09:42 Voltage Offset Correction: v_off_ini = 61.671 uV, v_off_fin = 64.426 uV 15:09:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.542 uVs 15:09:42 Integrated Voltage Measurement... 15:09:51 Voltage Offset Correction: v_off_ini = 66.794 uV, v_off_fin = 66.337 uV 15:09:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.329 uVs 15:09:55 I1X Average and RMS of Measurements VT = -103.377 +- 4.299 uVs I1X = 20.676 +- 0.859 uTm 15:09:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:10:02 Integrated Voltage Measurement... 15:10:11 Voltage Offset Correction: v_off_ini = 63.949 uV, v_off_fin = 54.526 uV 15:10:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -197.905 uVs 15:10:11 Integrated Voltage Measurement... 15:10:20 Voltage Offset Correction: v_off_ini = 78.585 uV, v_off_fin = 76.942 uV 15:10:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.488 uVs 15:10:20 Integrated Voltage Measurement... 15:10:29 Voltage Offset Correction: v_off_ini = 70.824 uV, v_off_fin = 74.662 uV 15:10:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.271 uVs 15:10:29 Integrated Voltage Measurement... 15:10:38 Voltage Offset Correction: v_off_ini = 75.147 uV, v_off_fin = 84.635 uV 15:10:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 194.977 uVs 15:10:38 Integrated Voltage Measurement... 15:10:47 Voltage Offset Correction: v_off_ini = 75.377 uV, v_off_fin = 61.735 uV 15:10:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.997 uVs 15:10:47 Integrated Voltage Measurement... 15:10:56 Voltage Offset Correction: v_off_ini = 70.525 uV, v_off_fin = 87.808 uV 15:10:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 198.315 uVs 15:11:00 I1Y Average and RMS of Measurements VT = -196.159 +- 2.168 uVs I1Y = -39.228 +- 0.434 uTm 15:11:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:08 Integrated Voltage Measurement... 15:11:17 Voltage Offset Correction: v_off_ini = 59.512 uV, v_off_fin = 66.338 uV 15:11:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.294 uVs 15:11:17 Integrated Voltage Measurement... 15:11:26 Voltage Offset Correction: v_off_ini = 82.173 uV, v_off_fin = 98.229 uV 15:11:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.997 uVs 15:11:26 Integrated Voltage Measurement... 15:11:35 Voltage Offset Correction: v_off_ini = 86.065 uV, v_off_fin = 70.150 uV 15:11:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.722 uVs 15:11:35 Integrated Voltage Measurement... 15:11:44 Voltage Offset Correction: v_off_ini = 94.135 uV, v_off_fin = 95.477 uV 15:11:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 115.240 uVs 15:11:44 Integrated Voltage Measurement... 15:11:53 Voltage Offset Correction: v_off_ini = 67.086 uV, v_off_fin = 61.505 uV 15:11:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.495 uVs 15:11:53 Integrated Voltage Measurement... 15:12:02 Voltage Offset Correction: v_off_ini = 78.106 uV, v_off_fin = 77.191 uV 15:12:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.020 uVs 15:12:04 I2X Average and RMS of Measurements VT = -104.295 +- 4.014 uVs I2X = 9.596 +- 0.370 uTm^2 15:12:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:12 Integrated Voltage Measurement... 15:12:21 Voltage Offset Correction: v_off_ini = 83.257 uV, v_off_fin = 73.477 uV 15:12:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.719 uVs 15:12:21 Integrated Voltage Measurement... 15:12:30 Voltage Offset Correction: v_off_ini = 86.227 uV, v_off_fin = 62.957 uV 15:12:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.837 uVs 15:12:30 Integrated Voltage Measurement... 15:12:39 Voltage Offset Correction: v_off_ini = 82.362 uV, v_off_fin = 90.318 uV 15:12:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.941 uVs 15:12:39 Integrated Voltage Measurement... 15:12:48 Voltage Offset Correction: v_off_ini = 74.979 uV, v_off_fin = 88.786 uV 15:12:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.603 uVs 15:12:48 Integrated Voltage Measurement... 15:12:57 Voltage Offset Correction: v_off_ini = 83.343 uV, v_off_fin = 82.096 uV 15:12:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.553 uVs 15:12:57 Integrated Voltage Measurement... 15:13:06 Voltage Offset Correction: v_off_ini = 78.118 uV, v_off_fin = 81.238 uV 15:13:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.126 uVs 15:13:09 I2Y Average and RMS of Measurements VT = -250.797 +- 4.439 uVs I2Y = -23.073 +- 0.408 uTm^2 15:13:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:27 Integrated Voltage Measurement... 15:13:36 Voltage Offset Correction: v_off_ini = 109.852 uV, v_off_fin = 99.907 uV 15:13:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.323 uVs 15:13:36 Integrated Voltage Measurement... 15:13:45 Voltage Offset Correction: v_off_ini = 111.448 uV, v_off_fin = 107.472 uV 15:13:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.792 uVs 15:13:45 Integrated Voltage Measurement... 15:13:54 Voltage Offset Correction: v_off_ini = 122.807 uV, v_off_fin = 98.840 uV 15:13:54 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.428 uVs 15:13:54 Integrated Voltage Measurement... 15:14:03 Voltage Offset Correction: v_off_ini = 105.521 uV, v_off_fin = 104.193 uV 15:14:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.276 uVs 15:14:03 Integrated Voltage Measurement... 15:14:12 Voltage Offset Correction: v_off_ini = 103.866 uV, v_off_fin = 97.583 uV 15:14:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.830 uVs 15:14:12 Integrated Voltage Measurement... 15:14:21 Voltage Offset Correction: v_off_ini = 99.241 uV, v_off_fin = 100.306 uV 15:14:21 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.525 uVs 15:14:25 I1X Average and RMS of Measurements VT = -95.696 +- 5.059 uVs I1X = 19.140 +- 1.012 uTm 15:14:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:32 Integrated Voltage Measurement... 15:14:41 Voltage Offset Correction: v_off_ini = 86.428 uV, v_off_fin = 79.248 uV 15:14:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.977 uVs 15:14:41 Integrated Voltage Measurement... 15:14:50 Voltage Offset Correction: v_off_ini = 99.857 uV, v_off_fin = 107.764 uV 15:14:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.871 uVs 15:14:50 Integrated Voltage Measurement... 15:14:59 Voltage Offset Correction: v_off_ini = 103.610 uV, v_off_fin = 78.537 uV 15:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -190.334 uVs 15:14:59 Integrated Voltage Measurement... 15:15:08 Voltage Offset Correction: v_off_ini = 97.857 uV, v_off_fin = 103.318 uV 15:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.432 uVs 15:15:08 Integrated Voltage Measurement... 15:15:17 Voltage Offset Correction: v_off_ini = 103.570 uV, v_off_fin = 106.247 uV 15:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -212.578 uVs 15:15:17 Integrated Voltage Measurement... 15:15:26 Voltage Offset Correction: v_off_ini = 93.164 uV, v_off_fin = 105.317 uV 15:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 200.909 uVs 15:15:30 I1Y Average and RMS of Measurements VT = -200.850 +- 4.189 uVs I1Y = -40.168 +- 0.836 uTm 15:15:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:15:38 Integrated Voltage Measurement... 15:15:47 Voltage Offset Correction: v_off_ini = 93.834 uV, v_off_fin = 91.638 uV 15:15:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.288 uVs 15:15:47 Integrated Voltage Measurement... 15:15:56 Voltage Offset Correction: v_off_ini = 113.019 uV, v_off_fin = 113.444 uV 15:15:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.835 uVs 15:15:56 Integrated Voltage Measurement... 15:16:05 Voltage Offset Correction: v_off_ini = 108.936 uV, v_off_fin = 100.507 uV 15:16:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.002 uVs 15:16:05 Integrated Voltage Measurement... 15:16:14 Voltage Offset Correction: v_off_ini = 103.809 uV, v_off_fin = 118.988 uV 15:16:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.505 uVs 15:16:14 Integrated Voltage Measurement... 15:16:23 Voltage Offset Correction: v_off_ini = 110.313 uV, v_off_fin = 113.591 uV 15:16:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.591 uVs 15:16:23 Integrated Voltage Measurement... 15:16:32 Voltage Offset Correction: v_off_ini = 119.836 uV, v_off_fin = 129.662 uV 15:16:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.356 uVs 15:16:34 I2X Average and RMS of Measurements VT = -104.596 +- 8.459 uVs I2X = 9.623 +- 0.778 uTm^2 15:16:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:16:42 Integrated Voltage Measurement... 15:16:51 Voltage Offset Correction: v_off_ini = 116.503 uV, v_off_fin = 120.731 uV 15:16:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.369 uVs 15:16:51 Integrated Voltage Measurement... 15:17:00 Voltage Offset Correction: v_off_ini = 126.116 uV, v_off_fin = 133.016 uV 15:17:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.088 uVs 15:17:00 Integrated Voltage Measurement... 15:17:09 Voltage Offset Correction: v_off_ini = 121.567 uV, v_off_fin = 130.540 uV 15:17:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.357 uVs 15:17:09 Integrated Voltage Measurement... 15:17:18 Voltage Offset Correction: v_off_ini = 135.649 uV, v_off_fin = 133.512 uV 15:17:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.054 uVs 15:17:18 Integrated Voltage Measurement... 15:17:27 Voltage Offset Correction: v_off_ini = 129.370 uV, v_off_fin = 117.924 uV 15:17:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.702 uVs 15:17:27 Integrated Voltage Measurement... 15:17:36 Voltage Offset Correction: v_off_ini = 126.147 uV, v_off_fin = 124.395 uV 15:17:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.311 uVs 15:17:38 I2Y Average and RMS of Measurements VT = -246.647 +- 3.685 uVs I2Y = -22.691 +- 0.339 uTm^2 15:17:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm