SLAC Magnetic Measurements Date: 09-30-2025 Time: 16:00:29 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16345 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 16:00:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:00:39 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:00:41 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:00:42 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:00:44 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 16:01:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:01:22 Integrated Voltage Measurement... 16:01:31 Voltage Offset Correction: v_off_ini = -268.339 uV, v_off_fin = -271.929 uV 16:01:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.712 uVs 16:01:31 Integrated Voltage Measurement... 16:01:40 Voltage Offset Correction: v_off_ini = -276.880 uV, v_off_fin = -292.546 uV 16:01:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 75.253 uVs 16:01:40 Integrated Voltage Measurement... 16:01:49 Voltage Offset Correction: v_off_ini = -280.946 uV, v_off_fin = -276.469 uV 16:01:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.409 uVs 16:01:49 Integrated Voltage Measurement... 16:01:58 Voltage Offset Correction: v_off_ini = -281.289 uV, v_off_fin = -286.639 uV 16:01:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.458 uVs 16:01:58 Integrated Voltage Measurement... 16:02:07 Voltage Offset Correction: v_off_ini = -289.319 uV, v_off_fin = -287.000 uV 16:02:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.791 uVs 16:02:07 Integrated Voltage Measurement... 16:02:16 Voltage Offset Correction: v_off_ini = -294.337 uV, v_off_fin = -284.568 uV 16:02:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.490 uVs 16:02:20 I1X Average and RMS of Measurements VT = -85.185 +- 7.187 uVs I1X = 17.038 +- 1.437 uTm 16:02:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:02:26 Integrated Voltage Measurement... 16:02:35 Voltage Offset Correction: v_off_ini = -282.476 uV, v_off_fin = -293.301 uV 16:02:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -206.438 uVs 16:02:35 Integrated Voltage Measurement... 16:02:44 Voltage Offset Correction: v_off_ini = -274.617 uV, v_off_fin = -271.106 uV 16:02:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.780 uVs 16:02:44 Integrated Voltage Measurement... 16:02:53 Voltage Offset Correction: v_off_ini = -276.944 uV, v_off_fin = -293.507 uV 16:02:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.145 uVs 16:02:53 Integrated Voltage Measurement... 16:03:02 Voltage Offset Correction: v_off_ini = -281.691 uV, v_off_fin = -265.669 uV 16:03:02 Integrated Voltage Measurement dXYus = -0.5001 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.400 uVs 16:03:02 Integrated Voltage Measurement... 16:03:11 Voltage Offset Correction: v_off_ini = -282.212 uV, v_off_fin = -285.585 uV 16:03:11 Integrated Voltage Measurement dXYus = 0.5001 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.157 uVs 16:03:11 Integrated Voltage Measurement... 16:03:20 Voltage Offset Correction: v_off_ini = -268.792 uV, v_off_fin = -264.698 uV 16:03:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.584 uVs 16:03:25 I1Y Average and RMS of Measurements VT = -210.584 +- 5.045 uVs I1Y = -42.116 +- 1.007 uTm 16:03:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:03:32 Integrated Voltage Measurement... 16:03:41 Voltage Offset Correction: v_off_ini = -275.397 uV, v_off_fin = -274.450 uV 16:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.718 uVs 16:03:41 Integrated Voltage Measurement... 16:03:50 Voltage Offset Correction: v_off_ini = -262.684 uV, v_off_fin = -258.982 uV 16:03:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.223 uVs 16:03:50 Integrated Voltage Measurement... 16:03:59 Voltage Offset Correction: v_off_ini = -273.972 uV, v_off_fin = -277.350 uV 16:03:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.432 uVs 16:03:59 Integrated Voltage Measurement... 16:04:08 Voltage Offset Correction: v_off_ini = -273.402 uV, v_off_fin = -261.565 uV 16:04:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.826 uVs 16:04:08 Integrated Voltage Measurement... 16:04:17 Voltage Offset Correction: v_off_ini = -271.625 uV, v_off_fin = -276.227 uV 16:04:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -61.003 uVs 16:04:17 Integrated Voltage Measurement... 16:04:26 Voltage Offset Correction: v_off_ini = -269.406 uV, v_off_fin = -257.866 uV 16:04:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.262 uVs 16:04:29 I2X Average and RMS of Measurements VT = -57.577 +- 1.569 uVs I2X = 5.297 +- 0.144 uTm^2 16:04:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:04:36 Integrated Voltage Measurement... 16:04:45 Voltage Offset Correction: v_off_ini = -270.646 uV, v_off_fin = -263.105 uV 16:04:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.137 uVs 16:04:46 Integrated Voltage Measurement... 16:04:54 Voltage Offset Correction: v_off_ini = -253.744 uV, v_off_fin = -261.661 uV 16:04:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 341.338 uVs 16:04:55 Integrated Voltage Measurement... 16:05:03 Voltage Offset Correction: v_off_ini = -261.031 uV, v_off_fin = -267.955 uV 16:05:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.627 uVs 16:05:04 Integrated Voltage Measurement... 16:05:13 Voltage Offset Correction: v_off_ini = -260.177 uV, v_off_fin = -255.291 uV 16:05:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 318.712 uVs 16:05:13 Integrated Voltage Measurement... 16:05:22 Voltage Offset Correction: v_off_ini = -263.344 uV, v_off_fin = -262.863 uV 16:05:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -338.150 uVs 16:05:22 Integrated Voltage Measurement... 16:05:31 Voltage Offset Correction: v_off_ini = -262.919 uV, v_off_fin = -255.123 uV 16:05:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 337.666 uVs 16:05:33 I2Y Average and RMS of Measurements VT = -333.272 +- 6.437 uVs I2Y = -30.661 +- 0.591 uTm^2 16:05:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:05:48 Integrated Voltage Measurement... 16:05:57 Voltage Offset Correction: v_off_ini = -269.888 uV, v_off_fin = -282.725 uV 16:05:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.327 uVs 16:05:57 Integrated Voltage Measurement... 16:06:06 Voltage Offset Correction: v_off_ini = -242.972 uV, v_off_fin = -256.266 uV 16:06:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.862 uVs 16:06:06 Integrated Voltage Measurement... 16:06:15 Voltage Offset Correction: v_off_ini = -264.535 uV, v_off_fin = -268.837 uV 16:06:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.797 uVs 16:06:15 Integrated Voltage Measurement... 16:06:24 Voltage Offset Correction: v_off_ini = -253.823 uV, v_off_fin = -247.366 uV 16:06:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.829 uVs 16:06:24 Integrated Voltage Measurement... 16:06:33 Voltage Offset Correction: v_off_ini = -258.360 uV, v_off_fin = -257.177 uV 16:06:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.529 uVs 16:06:33 Integrated Voltage Measurement... 16:06:42 Voltage Offset Correction: v_off_ini = -252.484 uV, v_off_fin = -241.909 uV 16:06:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.698 uVs 16:06:46 I1X Average and RMS of Measurements VT = -86.007 +- 12.616 uVs I1X = 17.201 +- 2.523 uTm 16:06:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:06:53 Integrated Voltage Measurement... 16:07:02 Voltage Offset Correction: v_off_ini = -219.080 uV, v_off_fin = -233.620 uV 16:07:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -199.182 uVs 16:07:02 Integrated Voltage Measurement... 16:07:11 Voltage Offset Correction: v_off_ini = -222.856 uV, v_off_fin = -217.852 uV 16:07:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.017 uVs 16:07:11 Integrated Voltage Measurement... 16:07:20 Voltage Offset Correction: v_off_ini = -250.278 uV, v_off_fin = -255.379 uV 16:07:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.011 uVs 16:07:20 Integrated Voltage Measurement... 16:07:29 Voltage Offset Correction: v_off_ini = -246.741 uV, v_off_fin = -235.271 uV 16:07:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.858 uVs 16:07:29 Integrated Voltage Measurement... 16:07:38 Voltage Offset Correction: v_off_ini = -226.942 uV, v_off_fin = -244.513 uV 16:07:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -185.936 uVs 16:07:38 Integrated Voltage Measurement... 16:07:47 Voltage Offset Correction: v_off_ini = -216.308 uV, v_off_fin = -213.464 uV 16:07:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.377 uVs 16:07:51 I1Y Average and RMS of Measurements VT = -193.230 +- 2.677 uVs I1Y = -38.647 +- 0.536 uTm 16:07:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:07:59 Integrated Voltage Measurement... 16:08:07 Voltage Offset Correction: v_off_ini = -216.642 uV, v_off_fin = -219.235 uV 16:08:07 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -77.376 uVs 16:08:08 Integrated Voltage Measurement... 16:08:16 Voltage Offset Correction: v_off_ini = -208.060 uV, v_off_fin = -190.307 uV 16:08:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 71.436 uVs 16:08:17 Integrated Voltage Measurement... 16:08:25 Voltage Offset Correction: v_off_ini = -220.757 uV, v_off_fin = -226.487 uV 16:08:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -77.763 uVs 16:08:26 Integrated Voltage Measurement... 16:08:35 Voltage Offset Correction: v_off_ini = -229.110 uV, v_off_fin = -211.229 uV 16:08:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.749 uVs 16:08:35 Integrated Voltage Measurement... 16:08:44 Voltage Offset Correction: v_off_ini = -234.609 uV, v_off_fin = -212.568 uV 16:08:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.216 uVs 16:08:44 Integrated Voltage Measurement... 16:08:53 Voltage Offset Correction: v_off_ini = -202.228 uV, v_off_fin = -197.612 uV 16:08:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.730 uVs 16:08:55 I2X Average and RMS of Measurements VT = -68.045 +- 11.072 uVs I2X = 6.260 +- 1.019 uTm^2 16:09:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:03 Integrated Voltage Measurement... 16:09:12 Voltage Offset Correction: v_off_ini = -188.081 uV, v_off_fin = -211.121 uV 16:09:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.519 uVs 16:09:12 Integrated Voltage Measurement... 16:09:21 Voltage Offset Correction: v_off_ini = -201.587 uV, v_off_fin = -200.570 uV 16:09:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.244 uVs 16:09:21 Integrated Voltage Measurement... 16:09:30 Voltage Offset Correction: v_off_ini = -198.757 uV, v_off_fin = -196.311 uV 16:09:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.855 uVs 16:09:30 Integrated Voltage Measurement... 16:09:39 Voltage Offset Correction: v_off_ini = -176.718 uV, v_off_fin = -183.940 uV 16:09:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.609 uVs 16:09:39 Integrated Voltage Measurement... 16:09:48 Voltage Offset Correction: v_off_ini = -186.844 uV, v_off_fin = -191.932 uV 16:09:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.834 uVs 16:09:48 Integrated Voltage Measurement... 16:09:57 Voltage Offset Correction: v_off_ini = -194.365 uV, v_off_fin = -187.013 uV 16:09:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 311.691 uVs 16:09:59 I2Y Average and RMS of Measurements VT = -314.792 +- 9.293 uVs I2Y = -28.961 +- 0.855 uTm^2 16:10:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:14 Integrated Voltage Measurement... 16:10:23 Voltage Offset Correction: v_off_ini = -151.004 uV, v_off_fin = -158.274 uV 16:10:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.129 uVs 16:10:23 Integrated Voltage Measurement... 16:10:32 Voltage Offset Correction: v_off_ini = -162.603 uV, v_off_fin = -154.829 uV 16:10:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 93.610 uVs 16:10:32 Integrated Voltage Measurement... 16:10:41 Voltage Offset Correction: v_off_ini = -162.465 uV, v_off_fin = -168.282 uV 16:10:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.444 uVs 16:10:41 Integrated Voltage Measurement... 16:10:50 Voltage Offset Correction: v_off_ini = -148.459 uV, v_off_fin = -135.814 uV 16:10:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.505 uVs 16:10:50 Integrated Voltage Measurement... 16:10:59 Voltage Offset Correction: v_off_ini = -136.159 uV, v_off_fin = -156.216 uV 16:10:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.920 uVs 16:10:59 Integrated Voltage Measurement... 16:11:08 Voltage Offset Correction: v_off_ini = -163.972 uV, v_off_fin = -161.380 uV 16:11:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.288 uVs 16:11:12 I1X Average and RMS of Measurements VT = -93.149 +- 1.836 uVs I1X = 18.631 +- 0.368 uTm 16:11:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:11:19 Integrated Voltage Measurement... 16:11:28 Voltage Offset Correction: v_off_ini = -156.214 uV, v_off_fin = -155.641 uV 16:11:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -189.156 uVs 16:11:28 Integrated Voltage Measurement... 16:11:37 Voltage Offset Correction: v_off_ini = -144.742 uV, v_off_fin = -143.006 uV 16:11:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.641 uVs 16:11:37 Integrated Voltage Measurement... 16:11:46 Voltage Offset Correction: v_off_ini = -158.117 uV, v_off_fin = -169.057 uV 16:11:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.651 uVs 16:11:46 Integrated Voltage Measurement... 16:11:55 Voltage Offset Correction: v_off_ini = -160.073 uV, v_off_fin = -150.795 uV 16:11:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.111 uVs 16:11:55 Integrated Voltage Measurement... 16:12:04 Voltage Offset Correction: v_off_ini = -160.998 uV, v_off_fin = -170.839 uV 16:12:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.999 uVs 16:12:04 Integrated Voltage Measurement... 16:12:13 Voltage Offset Correction: v_off_ini = -160.072 uV, v_off_fin = -140.748 uV 16:12:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.485 uVs 16:12:17 I1Y Average and RMS of Measurements VT = -180.007 +- 5.725 uVs I1Y = -36.002 +- 1.146 uTm 16:12:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:12:24 Integrated Voltage Measurement... 16:12:33 Voltage Offset Correction: v_off_ini = -157.278 uV, v_off_fin = -176.847 uV 16:12:33 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -92.388 uVs 16:12:33 Integrated Voltage Measurement... 16:12:42 Voltage Offset Correction: v_off_ini = -172.562 uV, v_off_fin = -154.392 uV 16:12:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.250 uVs 16:12:42 Integrated Voltage Measurement... 16:12:51 Voltage Offset Correction: v_off_ini = -151.687 uV, v_off_fin = -177.266 uV 16:12:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.529 uVs 16:12:51 Integrated Voltage Measurement... 16:13:00 Voltage Offset Correction: v_off_ini = -150.473 uV, v_off_fin = -151.700 uV 16:13:00 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 73.203 uVs 16:13:00 Integrated Voltage Measurement... 16:13:09 Voltage Offset Correction: v_off_ini = -159.563 uV, v_off_fin = -172.642 uV 16:13:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.903 uVs 16:13:09 Integrated Voltage Measurement... 16:13:18 Voltage Offset Correction: v_off_ini = -152.348 uV, v_off_fin = -153.933 uV 16:13:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.575 uVs 16:13:21 I2X Average and RMS of Measurements VT = -82.475 +- 7.586 uVs I2X = 7.587 +- 0.698 uTm^2 16:13:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:13:28 Integrated Voltage Measurement... 16:13:37 Voltage Offset Correction: v_off_ini = -148.508 uV, v_off_fin = -143.782 uV 16:13:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.440 uVs 16:13:38 Integrated Voltage Measurement... 16:13:46 Voltage Offset Correction: v_off_ini = -140.959 uV, v_off_fin = -134.128 uV 16:13:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.322 uVs 16:13:47 Integrated Voltage Measurement... 16:13:55 Voltage Offset Correction: v_off_ini = -140.326 uV, v_off_fin = -127.781 uV 16:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.344 uVs 16:13:56 Integrated Voltage Measurement... 16:14:04 Voltage Offset Correction: v_off_ini = -143.992 uV, v_off_fin = -148.544 uV 16:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.136 uVs 16:14:05 Integrated Voltage Measurement... 16:14:13 Voltage Offset Correction: v_off_ini = -139.643 uV, v_off_fin = -144.468 uV 16:14:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -311.525 uVs 16:14:14 Integrated Voltage Measurement... 16:14:22 Voltage Offset Correction: v_off_ini = -145.114 uV, v_off_fin = -146.542 uV 16:14:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.633 uVs 16:14:25 I2Y Average and RMS of Measurements VT = -307.733 +- 7.981 uVs I2Y = -28.311 +- 0.734 uTm^2 16:14:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:14:40 Integrated Voltage Measurement... 16:14:49 Voltage Offset Correction: v_off_ini = -141.741 uV, v_off_fin = -146.612 uV 16:14:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.370 uVs 16:14:49 Integrated Voltage Measurement... 16:14:58 Voltage Offset Correction: v_off_ini = -144.273 uV, v_off_fin = -150.755 uV 16:14:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.671 uVs 16:14:58 Integrated Voltage Measurement... 16:15:07 Voltage Offset Correction: v_off_ini = -144.910 uV, v_off_fin = -143.183 uV 16:15:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.833 uVs 16:15:07 Integrated Voltage Measurement... 16:15:16 Voltage Offset Correction: v_off_ini = -144.374 uV, v_off_fin = -137.530 uV 16:15:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.117 uVs 16:15:16 Integrated Voltage Measurement... 16:15:25 Voltage Offset Correction: v_off_ini = -133.026 uV, v_off_fin = -132.392 uV 16:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.831 uVs 16:15:25 Integrated Voltage Measurement... 16:15:34 Voltage Offset Correction: v_off_ini = -138.280 uV, v_off_fin = -138.499 uV 16:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.486 uVs 16:15:38 I1X Average and RMS of Measurements VT = -100.718 +- 0.690 uVs I1X = 20.144 +- 0.138 uTm 16:15:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:15:45 Integrated Voltage Measurement... 16:15:54 Voltage Offset Correction: v_off_ini = -146.642 uV, v_off_fin = -155.978 uV 16:15:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.987 uVs 16:15:54 Integrated Voltage Measurement... 16:16:03 Voltage Offset Correction: v_off_ini = -145.131 uV, v_off_fin = -133.332 uV 16:16:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 175.087 uVs 16:16:03 Integrated Voltage Measurement... 16:16:11 Voltage Offset Correction: v_off_ini = -144.638 uV, v_off_fin = -149.195 uV 16:16:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -168.905 uVs 16:16:12 Integrated Voltage Measurement... 16:16:20 Voltage Offset Correction: v_off_ini = -139.902 uV, v_off_fin = -129.711 uV 16:16:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.036 uVs 16:16:20 Integrated Voltage Measurement... 16:16:29 Voltage Offset Correction: v_off_ini = -140.423 uV, v_off_fin = -148.987 uV 16:16:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.713 uVs 16:16:29 Integrated Voltage Measurement... 16:16:38 Voltage Offset Correction: v_off_ini = -158.036 uV, v_off_fin = -147.638 uV 16:16:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 186.687 uVs 16:16:43 I1Y Average and RMS of Measurements VT = -174.069 +- 2.246 uVs I1Y = -34.813 +- 0.448 uTm 16:16:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:50 Integrated Voltage Measurement... 16:16:59 Voltage Offset Correction: v_off_ini = -144.025 uV, v_off_fin = -150.070 uV 16:16:59 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -85.991 uVs 16:16:59 Integrated Voltage Measurement... 16:17:08 Voltage Offset Correction: v_off_ini = -143.772 uV, v_off_fin = -135.815 uV 16:17:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.206 uVs 16:17:08 Integrated Voltage Measurement... 16:17:17 Voltage Offset Correction: v_off_ini = -148.489 uV, v_off_fin = -162.203 uV 16:17:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -86.695 uVs 16:17:17 Integrated Voltage Measurement... 16:17:26 Voltage Offset Correction: v_off_ini = -166.640 uV, v_off_fin = -159.213 uV 16:17:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.310 uVs 16:17:26 Integrated Voltage Measurement... 16:17:35 Voltage Offset Correction: v_off_ini = -165.320 uV, v_off_fin = -174.034 uV 16:17:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.504 uVs 16:17:35 Integrated Voltage Measurement... 16:17:44 Voltage Offset Correction: v_off_ini = -163.433 uV, v_off_fin = -157.551 uV 16:17:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 96.143 uVs 16:17:47 I2X Average and RMS of Measurements VT = -84.308 +- 5.109 uVs I2X = 7.756 +- 0.470 uTm^2 16:17:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:17:54 Integrated Voltage Measurement... 16:18:03 Voltage Offset Correction: v_off_ini = -157.546 uV, v_off_fin = -164.453 uV 16:18:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -288.926 uVs 16:18:03 Integrated Voltage Measurement... 16:18:12 Voltage Offset Correction: v_off_ini = -166.843 uV, v_off_fin = -163.732 uV 16:18:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.031 uVs 16:18:12 Integrated Voltage Measurement... 16:18:21 Voltage Offset Correction: v_off_ini = -185.240 uV, v_off_fin = -176.256 uV 16:18:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.465 uVs 16:18:21 Integrated Voltage Measurement... 16:18:30 Voltage Offset Correction: v_off_ini = -171.514 uV, v_off_fin = -184.787 uV 16:18:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.266 uVs 16:18:30 Integrated Voltage Measurement... 16:18:39 Voltage Offset Correction: v_off_ini = -178.023 uV, v_off_fin = -173.598 uV 16:18:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.767 uVs 16:18:39 Integrated Voltage Measurement... 16:18:48 Voltage Offset Correction: v_off_ini = -165.958 uV, v_off_fin = -165.592 uV 16:18:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.942 uVs 16:18:51 I2Y Average and RMS of Measurements VT = -283.900 +- 5.709 uVs I2Y = -26.119 +- 0.525 uTm^2 16:19:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:06 Integrated Voltage Measurement... 16:19:15 Voltage Offset Correction: v_off_ini = -147.240 uV, v_off_fin = -159.773 uV 16:19:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.283 uVs 16:19:15 Integrated Voltage Measurement... 16:19:24 Voltage Offset Correction: v_off_ini = -145.345 uV, v_off_fin = -135.451 uV 16:19:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.695 uVs 16:19:24 Integrated Voltage Measurement... 16:19:33 Voltage Offset Correction: v_off_ini = -135.789 uV, v_off_fin = -136.145 uV 16:19:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.047 uVs 16:19:33 Integrated Voltage Measurement... 16:19:42 Voltage Offset Correction: v_off_ini = -135.388 uV, v_off_fin = -149.043 uV 16:19:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.672 uVs 16:19:42 Integrated Voltage Measurement... 16:19:51 Voltage Offset Correction: v_off_ini = -132.525 uV, v_off_fin = -144.493 uV 16:19:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.390 uVs 16:19:51 Integrated Voltage Measurement... 16:20:00 Voltage Offset Correction: v_off_ini = -163.759 uV, v_off_fin = -152.498 uV 16:20:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.598 uVs 16:20:04 I1X Average and RMS of Measurements VT = -115.781 +- 5.971 uVs I1X = 23.156 +- 1.194 uTm 16:20:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:20:11 Integrated Voltage Measurement... 16:20:19 Voltage Offset Correction: v_off_ini = -164.190 uV, v_off_fin = -166.522 uV 16:20:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.878 uVs 16:20:19 Integrated Voltage Measurement... 16:20:28 Voltage Offset Correction: v_off_ini = -149.440 uV, v_off_fin = -156.939 uV 16:20:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.287 uVs 16:20:28 Integrated Voltage Measurement... 16:20:37 Voltage Offset Correction: v_off_ini = -165.125 uV, v_off_fin = -162.575 uV 16:20:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -173.157 uVs 16:20:37 Integrated Voltage Measurement... 16:20:46 Voltage Offset Correction: v_off_ini = -155.951 uV, v_off_fin = -148.870 uV 16:20:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.640 uVs 16:20:46 Integrated Voltage Measurement... 16:20:55 Voltage Offset Correction: v_off_ini = -156.914 uV, v_off_fin = -167.806 uV 16:20:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.491 uVs 16:20:55 Integrated Voltage Measurement... 16:21:04 Voltage Offset Correction: v_off_ini = -149.127 uV, v_off_fin = -139.215 uV 16:21:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.151 uVs 16:21:08 I1Y Average and RMS of Measurements VT = -168.434 +- 6.049 uVs I1Y = -33.687 +- 1.210 uTm 16:21:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:21:16 Integrated Voltage Measurement... 16:21:25 Voltage Offset Correction: v_off_ini = -156.042 uV, v_off_fin = -156.187 uV 16:21:25 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -95.668 uVs 16:21:25 Integrated Voltage Measurement... 16:21:34 Voltage Offset Correction: v_off_ini = -131.160 uV, v_off_fin = -133.216 uV 16:21:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.798 uVs 16:21:34 Integrated Voltage Measurement... 16:21:43 Voltage Offset Correction: v_off_ini = -148.334 uV, v_off_fin = -154.028 uV 16:21:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.714 uVs 16:21:43 Integrated Voltage Measurement... 16:21:52 Voltage Offset Correction: v_off_ini = -150.679 uV, v_off_fin = -129.981 uV 16:21:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.606 uVs 16:21:52 Integrated Voltage Measurement... 16:22:01 Voltage Offset Correction: v_off_ini = -139.413 uV, v_off_fin = -154.250 uV 16:22:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.138 uVs 16:22:01 Integrated Voltage Measurement... 16:22:10 Voltage Offset Correction: v_off_ini = -156.627 uV, v_off_fin = -125.323 uV 16:22:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 88.894 uVs 16:22:13 I2X Average and RMS of Measurements VT = -88.970 +- 4.782 uVs I2X = 8.185 +- 0.440 uTm^2 16:22:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:22:20 Integrated Voltage Measurement... 16:22:29 Voltage Offset Correction: v_off_ini = -151.180 uV, v_off_fin = -149.876 uV 16:22:29 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -280.667 uVs 16:22:29 Integrated Voltage Measurement... 16:22:38 Voltage Offset Correction: v_off_ini = -157.735 uV, v_off_fin = -163.646 uV 16:22:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.917 uVs 16:22:38 Integrated Voltage Measurement... 16:22:47 Voltage Offset Correction: v_off_ini = -171.565 uV, v_off_fin = -161.036 uV 16:22:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.689 uVs 16:22:47 Integrated Voltage Measurement... 16:22:56 Voltage Offset Correction: v_off_ini = -174.431 uV, v_off_fin = -152.458 uV 16:22:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.463 uVs 16:22:56 Integrated Voltage Measurement... 16:23:05 Voltage Offset Correction: v_off_ini = -142.767 uV, v_off_fin = -141.548 uV 16:23:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.552 uVs 16:23:05 Integrated Voltage Measurement... 16:23:14 Voltage Offset Correction: v_off_ini = -135.097 uV, v_off_fin = -150.723 uV 16:23:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.279 uVs 16:23:17 I2Y Average and RMS of Measurements VT = -270.261 +- 6.839 uVs I2Y = -24.864 +- 0.630 uTm^2 16:23:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:23:32 Integrated Voltage Measurement... 16:23:41 Voltage Offset Correction: v_off_ini = -138.516 uV, v_off_fin = -139.653 uV 16:23:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.820 uVs 16:23:41 Integrated Voltage Measurement... 16:23:50 Voltage Offset Correction: v_off_ini = -130.133 uV, v_off_fin = -119.566 uV 16:23:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.314 uVs 16:23:50 Integrated Voltage Measurement... 16:23:59 Voltage Offset Correction: v_off_ini = -139.515 uV, v_off_fin = -138.541 uV 16:23:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.453 uVs 16:23:59 Integrated Voltage Measurement... 16:24:08 Voltage Offset Correction: v_off_ini = -121.492 uV, v_off_fin = -121.411 uV 16:24:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.309 uVs 16:24:08 Integrated Voltage Measurement... 16:24:17 Voltage Offset Correction: v_off_ini = -127.976 uV, v_off_fin = -136.935 uV 16:24:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.314 uVs 16:24:17 Integrated Voltage Measurement... 16:24:26 Voltage Offset Correction: v_off_ini = -144.094 uV, v_off_fin = -134.181 uV 16:24:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.140 uVs 16:24:30 I1X Average and RMS of Measurements VT = -115.225 +- 6.408 uVs I1X = 23.045 +- 1.282 uTm 16:24:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:24:37 Integrated Voltage Measurement... 16:24:46 Voltage Offset Correction: v_off_ini = -136.723 uV, v_off_fin = -144.652 uV 16:24:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -161.686 uVs 16:24:46 Integrated Voltage Measurement... 16:24:55 Voltage Offset Correction: v_off_ini = -144.438 uV, v_off_fin = -145.390 uV 16:24:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.260 uVs 16:24:55 Integrated Voltage Measurement... 16:25:04 Voltage Offset Correction: v_off_ini = -132.850 uV, v_off_fin = -147.318 uV 16:25:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.812 uVs 16:25:04 Integrated Voltage Measurement... 16:25:13 Voltage Offset Correction: v_off_ini = -143.097 uV, v_off_fin = -123.719 uV 16:25:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.359 uVs 16:25:13 Integrated Voltage Measurement... 16:25:22 Voltage Offset Correction: v_off_ini = -143.517 uV, v_off_fin = -154.879 uV 16:25:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -147.369 uVs 16:25:22 Integrated Voltage Measurement... 16:25:31 Voltage Offset Correction: v_off_ini = -139.915 uV, v_off_fin = -126.399 uV 16:25:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.523 uVs 16:25:35 I1Y Average and RMS of Measurements VT = -156.668 +- 9.219 uVs I1Y = -31.333 +- 1.843 uTm 16:25:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:25:43 Integrated Voltage Measurement... 16:25:52 Voltage Offset Correction: v_off_ini = -154.593 uV, v_off_fin = -163.530 uV 16:25:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.847 uVs 16:25:52 Integrated Voltage Measurement... 16:26:01 Voltage Offset Correction: v_off_ini = -150.783 uV, v_off_fin = -129.914 uV 16:26:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.907 uVs 16:26:01 Integrated Voltage Measurement... 16:26:10 Voltage Offset Correction: v_off_ini = -146.601 uV, v_off_fin = -167.064 uV 16:26:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.808 uVs 16:26:10 Integrated Voltage Measurement... 16:26:19 Voltage Offset Correction: v_off_ini = -142.479 uV, v_off_fin = -147.028 uV 16:26:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.574 uVs 16:26:19 Integrated Voltage Measurement... 16:26:28 Voltage Offset Correction: v_off_ini = -154.517 uV, v_off_fin = -156.778 uV 16:26:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.710 uVs 16:26:28 Integrated Voltage Measurement... 16:26:37 Voltage Offset Correction: v_off_ini = -150.047 uV, v_off_fin = -139.140 uV 16:26:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.397 uVs 16:26:39 I2X Average and RMS of Measurements VT = -103.207 +- 4.878 uVs I2X = 9.495 +- 0.449 uTm^2 16:26:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:26:47 Integrated Voltage Measurement... 16:26:56 Voltage Offset Correction: v_off_ini = -146.653 uV, v_off_fin = -151.168 uV 16:26:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -235.608 uVs 16:26:56 Integrated Voltage Measurement... 16:27:05 Voltage Offset Correction: v_off_ini = -144.691 uV, v_off_fin = -136.781 uV 16:27:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.260 uVs 16:27:05 Integrated Voltage Measurement... 16:27:14 Voltage Offset Correction: v_off_ini = -142.843 uV, v_off_fin = -142.836 uV 16:27:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.761 uVs 16:27:14 Integrated Voltage Measurement... 16:27:23 Voltage Offset Correction: v_off_ini = -145.880 uV, v_off_fin = -131.702 uV 16:27:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.952 uVs 16:27:23 Integrated Voltage Measurement... 16:27:32 Voltage Offset Correction: v_off_ini = -143.352 uV, v_off_fin = -147.535 uV 16:27:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.263 uVs 16:27:32 Integrated Voltage Measurement... 16:27:41 Voltage Offset Correction: v_off_ini = -151.692 uV, v_off_fin = -136.709 uV 16:27:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.887 uVs 16:27:43 I2Y Average and RMS of Measurements VT = -252.622 +- 2.964 uVs I2Y = -23.242 +- 0.272 uTm^2 16:27:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:27:58 Integrated Voltage Measurement... 16:28:07 Voltage Offset Correction: v_off_ini = -128.724 uV, v_off_fin = -149.845 uV 16:28:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.815 uVs 16:28:07 Integrated Voltage Measurement... 16:28:16 Voltage Offset Correction: v_off_ini = -145.577 uV, v_off_fin = -143.023 uV 16:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.598 uVs 16:28:16 Integrated Voltage Measurement... 16:28:25 Voltage Offset Correction: v_off_ini = -140.827 uV, v_off_fin = -139.895 uV 16:28:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.873 uVs 16:28:25 Integrated Voltage Measurement... 16:28:34 Voltage Offset Correction: v_off_ini = -138.241 uV, v_off_fin = -133.443 uV 16:28:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.799 uVs 16:28:34 Integrated Voltage Measurement... 16:28:43 Voltage Offset Correction: v_off_ini = -136.316 uV, v_off_fin = -130.731 uV 16:28:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.237 uVs 16:28:43 Integrated Voltage Measurement... 16:28:52 Voltage Offset Correction: v_off_ini = -133.101 uV, v_off_fin = -126.853 uV 16:28:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.744 uVs 16:28:56 I1X Average and RMS of Measurements VT = -120.845 +- 3.834 uVs I1X = 24.169 +- 0.767 uTm 16:28:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:29:03 Integrated Voltage Measurement... 16:29:12 Voltage Offset Correction: v_off_ini = -109.074 uV, v_off_fin = -129.346 uV 16:29:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -159.890 uVs 16:29:12 Integrated Voltage Measurement... 16:29:21 Voltage Offset Correction: v_off_ini = -109.031 uV, v_off_fin = -105.498 uV 16:29:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 157.222 uVs 16:29:21 Integrated Voltage Measurement... 16:29:30 Voltage Offset Correction: v_off_ini = -122.888 uV, v_off_fin = -118.798 uV 16:29:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -154.677 uVs 16:29:30 Integrated Voltage Measurement... 16:29:39 Voltage Offset Correction: v_off_ini = -112.847 uV, v_off_fin = -114.795 uV 16:29:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 152.033 uVs 16:29:39 Integrated Voltage Measurement... 16:29:48 Voltage Offset Correction: v_off_ini = -114.420 uV, v_off_fin = -125.168 uV 16:29:48 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -139.296 uVs 16:29:48 Integrated Voltage Measurement... 16:29:57 Voltage Offset Correction: v_off_ini = -109.629 uV, v_off_fin = -108.067 uV 16:29:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 146.696 uVs 16:30:01 I1Y Average and RMS of Measurements VT = -151.636 +- 6.468 uVs I1Y = -30.326 +- 1.292 uTm 16:30:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:09 Integrated Voltage Measurement... 16:30:18 Voltage Offset Correction: v_off_ini = -122.299 uV, v_off_fin = -124.703 uV 16:30:18 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -94.467 uVs 16:30:18 Integrated Voltage Measurement... 16:30:27 Voltage Offset Correction: v_off_ini = -120.003 uV, v_off_fin = -105.935 uV 16:30:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.972 uVs 16:30:27 Integrated Voltage Measurement... 16:30:36 Voltage Offset Correction: v_off_ini = -114.495 uV, v_off_fin = -125.793 uV 16:30:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.598 uVs 16:30:36 Integrated Voltage Measurement... 16:30:45 Voltage Offset Correction: v_off_ini = -116.783 uV, v_off_fin = -108.755 uV 16:30:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.208 uVs 16:30:45 Integrated Voltage Measurement... 16:30:54 Voltage Offset Correction: v_off_ini = -121.900 uV, v_off_fin = -124.803 uV 16:30:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.628 uVs 16:30:54 Integrated Voltage Measurement... 16:31:03 Voltage Offset Correction: v_off_ini = -115.830 uV, v_off_fin = -91.627 uV 16:31:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.084 uVs 16:31:05 I2X Average and RMS of Measurements VT = -108.160 +- 8.184 uVs I2X = 9.950 +- 0.753 uTm^2 16:31:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:13 Integrated Voltage Measurement... 16:31:22 Voltage Offset Correction: v_off_ini = -113.483 uV, v_off_fin = -109.525 uV 16:31:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.889 uVs 16:31:22 Integrated Voltage Measurement... 16:31:31 Voltage Offset Correction: v_off_ini = -122.588 uV, v_off_fin = -113.257 uV 16:31:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.763 uVs 16:31:31 Integrated Voltage Measurement... 16:31:40 Voltage Offset Correction: v_off_ini = -112.138 uV, v_off_fin = -109.780 uV 16:31:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.376 uVs 16:31:40 Integrated Voltage Measurement... 16:31:49 Voltage Offset Correction: v_off_ini = -105.458 uV, v_off_fin = -100.712 uV 16:31:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.800 uVs 16:31:49 Integrated Voltage Measurement... 16:31:58 Voltage Offset Correction: v_off_ini = -92.898 uV, v_off_fin = -100.467 uV 16:31:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.585 uVs 16:31:58 Integrated Voltage Measurement... 16:32:07 Voltage Offset Correction: v_off_ini = -102.437 uV, v_off_fin = -98.808 uV 16:32:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.892 uVs 16:32:10 I2Y Average and RMS of Measurements VT = -254.717 +- 8.953 uVs I2Y = -23.434 +- 0.824 uTm^2 16:32:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:32:25 Integrated Voltage Measurement... 16:32:34 Voltage Offset Correction: v_off_ini = -110.789 uV, v_off_fin = -120.571 uV 16:32:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -103.374 uVs 16:32:34 Integrated Voltage Measurement... 16:32:43 Voltage Offset Correction: v_off_ini = -119.979 uV, v_off_fin = -104.473 uV 16:32:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 111.450 uVs 16:32:43 Integrated Voltage Measurement... 16:32:52 Voltage Offset Correction: v_off_ini = -111.832 uV, v_off_fin = -121.539 uV 16:32:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.586 uVs 16:32:52 Integrated Voltage Measurement... 16:33:01 Voltage Offset Correction: v_off_ini = -115.131 uV, v_off_fin = -100.987 uV 16:33:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.773 uVs 16:33:01 Integrated Voltage Measurement... 16:33:10 Voltage Offset Correction: v_off_ini = -107.524 uV, v_off_fin = -104.269 uV 16:33:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.722 uVs 16:33:10 Integrated Voltage Measurement... 16:33:19 Voltage Offset Correction: v_off_ini = -122.674 uV, v_off_fin = -115.502 uV 16:33:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.693 uVs 16:33:23 I1X Average and RMS of Measurements VT = -121.266 +- 9.797 uVs I1X = 24.254 +- 1.958 uTm 16:33:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:30 Integrated Voltage Measurement... 16:33:39 Voltage Offset Correction: v_off_ini = -106.576 uV, v_off_fin = -119.239 uV 16:33:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -159.528 uVs 16:33:39 Integrated Voltage Measurement... 16:33:47 Voltage Offset Correction: v_off_ini = -114.552 uV, v_off_fin = -101.755 uV 16:33:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 144.281 uVs 16:33:48 Integrated Voltage Measurement... 16:33:56 Voltage Offset Correction: v_off_ini = -118.707 uV, v_off_fin = -125.393 uV 16:33:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -129.160 uVs 16:33:57 Integrated Voltage Measurement... 16:34:05 Voltage Offset Correction: v_off_ini = -114.321 uV, v_off_fin = -110.032 uV 16:34:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 130.507 uVs 16:34:06 Integrated Voltage Measurement... 16:34:14 Voltage Offset Correction: v_off_ini = -126.258 uV, v_off_fin = -137.287 uV 16:34:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -145.880 uVs 16:34:15 Integrated Voltage Measurement... 16:34:23 Voltage Offset Correction: v_off_ini = -122.052 uV, v_off_fin = -121.119 uV 16:34:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.454 uVs 16:34:28 I1Y Average and RMS of Measurements VT = -142.635 +- 9.350 uVs I1Y = -28.526 +- 1.870 uTm 16:34:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:34:35 Integrated Voltage Measurement... 16:34:44 Voltage Offset Correction: v_off_ini = -149.151 uV, v_off_fin = -139.461 uV 16:34:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.323 uVs 16:34:44 Integrated Voltage Measurement... 16:34:53 Voltage Offset Correction: v_off_ini = -130.246 uV, v_off_fin = -115.151 uV 16:34:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.791 uVs 16:34:53 Integrated Voltage Measurement... 16:35:02 Voltage Offset Correction: v_off_ini = -120.350 uV, v_off_fin = -136.675 uV 16:35:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -121.670 uVs 16:35:02 Integrated Voltage Measurement... 16:35:11 Voltage Offset Correction: v_off_ini = -124.450 uV, v_off_fin = -123.569 uV 16:35:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.535 uVs 16:35:11 Integrated Voltage Measurement... 16:35:20 Voltage Offset Correction: v_off_ini = -126.705 uV, v_off_fin = -136.766 uV 16:35:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.278 uVs 16:35:20 Integrated Voltage Measurement... 16:35:29 Voltage Offset Correction: v_off_ini = -123.571 uV, v_off_fin = -118.775 uV 16:35:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.183 uVs 16:35:32 I2X Average and RMS of Measurements VT = -115.963 +- 1.867 uVs I2X = 10.669 +- 0.172 uTm^2 16:35:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:35:40 Integrated Voltage Measurement... 16:35:49 Voltage Offset Correction: v_off_ini = -117.852 uV, v_off_fin = -121.532 uV 16:35:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.355 uVs 16:35:49 Integrated Voltage Measurement... 16:35:58 Voltage Offset Correction: v_off_ini = -116.675 uV, v_off_fin = -105.661 uV 16:35:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.290 uVs 16:35:58 Integrated Voltage Measurement... 16:36:07 Voltage Offset Correction: v_off_ini = -132.640 uV, v_off_fin = -133.445 uV 16:36:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.606 uVs 16:36:07 Integrated Voltage Measurement... 16:36:16 Voltage Offset Correction: v_off_ini = -145.943 uV, v_off_fin = -145.630 uV 16:36:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.211 uVs 16:36:16 Integrated Voltage Measurement... 16:36:25 Voltage Offset Correction: v_off_ini = -130.760 uV, v_off_fin = -134.470 uV 16:36:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.545 uVs 16:36:25 Integrated Voltage Measurement... 16:36:34 Voltage Offset Correction: v_off_ini = -124.593 uV, v_off_fin = -136.164 uV 16:36:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.312 uVs 16:36:36 I2Y Average and RMS of Measurements VT = -240.053 +- 8.052 uVs I2Y = -22.085 +- 0.741 uTm^2 16:36:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:36:51 Integrated Voltage Measurement... 16:37:00 Voltage Offset Correction: v_off_ini = -123.739 uV, v_off_fin = -133.225 uV 16:37:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -121.766 uVs 16:37:00 Integrated Voltage Measurement... 16:37:09 Voltage Offset Correction: v_off_ini = -141.496 uV, v_off_fin = -130.008 uV 16:37:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.459 uVs 16:37:09 Integrated Voltage Measurement... 16:37:18 Voltage Offset Correction: v_off_ini = -132.417 uV, v_off_fin = -142.803 uV 16:37:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.756 uVs 16:37:18 Integrated Voltage Measurement... 16:37:27 Voltage Offset Correction: v_off_ini = -147.452 uV, v_off_fin = -146.093 uV 16:37:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.360 uVs 16:37:27 Integrated Voltage Measurement... 16:37:36 Voltage Offset Correction: v_off_ini = -144.310 uV, v_off_fin = -139.656 uV 16:37:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.641 uVs 16:37:36 Integrated Voltage Measurement... 16:37:45 Voltage Offset Correction: v_off_ini = -128.014 uV, v_off_fin = -137.869 uV 16:37:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.271 uVs 16:37:49 I1X Average and RMS of Measurements VT = -132.709 +- 1.249 uVs I1X = 26.541 +- 0.250 uTm 16:37:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:56 Integrated Voltage Measurement... 16:38:05 Voltage Offset Correction: v_off_ini = -123.668 uV, v_off_fin = -128.301 uV 16:38:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -139.498 uVs 16:38:05 Integrated Voltage Measurement... 16:38:14 Voltage Offset Correction: v_off_ini = -140.833 uV, v_off_fin = -128.795 uV 16:38:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 137.893 uVs 16:38:14 Integrated Voltage Measurement... 16:38:23 Voltage Offset Correction: v_off_ini = -138.392 uV, v_off_fin = -138.326 uV 16:38:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -138.766 uVs 16:38:23 Integrated Voltage Measurement... 16:38:32 Voltage Offset Correction: v_off_ini = -141.175 uV, v_off_fin = -141.879 uV 16:38:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 138.062 uVs 16:38:32 Integrated Voltage Measurement... 16:38:41 Voltage Offset Correction: v_off_ini = -153.614 uV, v_off_fin = -156.734 uV 16:38:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -131.535 uVs 16:38:41 Integrated Voltage Measurement... 16:38:50 Voltage Offset Correction: v_off_ini = -145.581 uV, v_off_fin = -132.353 uV 16:38:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 134.846 uVs 16:38:54 I1Y Average and RMS of Measurements VT = -136.767 +- 2.531 uVs I1Y = -27.352 +- 0.506 uTm 16:38:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:39:02 Integrated Voltage Measurement... 16:39:11 Voltage Offset Correction: v_off_ini = -117.473 uV, v_off_fin = -133.866 uV 16:39:11 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -139.489 uVs 16:39:11 Integrated Voltage Measurement... 16:39:20 Voltage Offset Correction: v_off_ini = -136.371 uV, v_off_fin = -124.822 uV 16:39:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.477 uVs 16:39:20 Integrated Voltage Measurement... 16:39:29 Voltage Offset Correction: v_off_ini = -131.704 uV, v_off_fin = -147.587 uV 16:39:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.326 uVs 16:39:29 Integrated Voltage Measurement... 16:39:38 Voltage Offset Correction: v_off_ini = -132.066 uV, v_off_fin = -124.648 uV 16:39:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.097 uVs 16:39:38 Integrated Voltage Measurement... 16:39:47 Voltage Offset Correction: v_off_ini = -132.465 uV, v_off_fin = -148.017 uV 16:39:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -126.881 uVs 16:39:47 Integrated Voltage Measurement... 16:39:56 Voltage Offset Correction: v_off_ini = -137.801 uV, v_off_fin = -124.311 uV 16:39:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 118.157 uVs 16:39:58 I2X Average and RMS of Measurements VT = -120.904 +- 8.152 uVs I2X = 11.123 +- 0.750 uTm^2 16:40:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:06 Integrated Voltage Measurement... 16:40:15 Voltage Offset Correction: v_off_ini = -127.974 uV, v_off_fin = -123.254 uV 16:40:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -236.330 uVs 16:40:15 Integrated Voltage Measurement... 16:40:24 Voltage Offset Correction: v_off_ini = -128.767 uV, v_off_fin = -125.043 uV 16:40:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.499 uVs 16:40:24 Integrated Voltage Measurement... 16:40:33 Voltage Offset Correction: v_off_ini = -116.912 uV, v_off_fin = -123.637 uV 16:40:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.495 uVs 16:40:33 Integrated Voltage Measurement... 16:40:42 Voltage Offset Correction: v_off_ini = -121.194 uV, v_off_fin = -127.497 uV 16:40:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.982 uVs 16:40:42 Integrated Voltage Measurement... 16:40:51 Voltage Offset Correction: v_off_ini = -126.841 uV, v_off_fin = -133.385 uV 16:40:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.794 uVs 16:40:51 Integrated Voltage Measurement... 16:41:00 Voltage Offset Correction: v_off_ini = -123.765 uV, v_off_fin = -121.387 uV 16:41:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.734 uVs 16:41:02 I2Y Average and RMS of Measurements VT = -231.306 +- 5.340 uVs I2Y = -21.280 +- 0.492 uTm^2 16:41:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:17 Integrated Voltage Measurement... 16:41:26 Voltage Offset Correction: v_off_ini = -127.062 uV, v_off_fin = -116.604 uV 16:41:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -123.708 uVs 16:41:26 Integrated Voltage Measurement... 16:41:35 Voltage Offset Correction: v_off_ini = -119.074 uV, v_off_fin = -116.501 uV 16:41:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.560 uVs 16:41:35 Integrated Voltage Measurement... 16:41:44 Voltage Offset Correction: v_off_ini = -105.478 uV, v_off_fin = -121.542 uV 16:41:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.073 uVs 16:41:44 Integrated Voltage Measurement... 16:41:53 Voltage Offset Correction: v_off_ini = -106.467 uV, v_off_fin = -101.449 uV 16:41:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.835 uVs 16:41:53 Integrated Voltage Measurement... 16:42:02 Voltage Offset Correction: v_off_ini = -100.350 uV, v_off_fin = -113.048 uV 16:42:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.898 uVs 16:42:02 Integrated Voltage Measurement... 16:42:11 Voltage Offset Correction: v_off_ini = -119.169 uV, v_off_fin = -114.757 uV 16:42:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.148 uVs 16:42:16 I1X Average and RMS of Measurements VT = -140.037 +- 6.627 uVs I1X = 28.007 +- 1.326 uTm 16:42:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:42:22 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = -105.735 uV, v_off_fin = -115.863 uV 16:42:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -135.178 uVs 16:42:31 Integrated Voltage Measurement... 16:42:40 Voltage Offset Correction: v_off_ini = -116.070 uV, v_off_fin = -99.860 uV 16:42:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 154.841 uVs 16:42:40 Integrated Voltage Measurement... 16:42:49 Voltage Offset Correction: v_off_ini = -109.473 uV, v_off_fin = -137.206 uV 16:42:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -127.132 uVs 16:42:49 Integrated Voltage Measurement... 16:42:58 Voltage Offset Correction: v_off_ini = -106.742 uV, v_off_fin = -105.931 uV 16:42:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 135.853 uVs 16:42:58 Integrated Voltage Measurement... 16:43:07 Voltage Offset Correction: v_off_ini = -103.401 uV, v_off_fin = -108.193 uV 16:43:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -125.633 uVs 16:43:07 Integrated Voltage Measurement... 16:43:16 Voltage Offset Correction: v_off_ini = -94.830 uV, v_off_fin = -82.206 uV 16:43:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 155.633 uVs 16:43:20 I1Y Average and RMS of Measurements VT = -139.045 +- 5.631 uVs I1Y = -27.807 +- 1.127 uTm 16:43:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:43:28 Integrated Voltage Measurement... 16:43:37 Voltage Offset Correction: v_off_ini = -112.604 uV, v_off_fin = -113.033 uV 16:43:37 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -140.416 uVs 16:43:37 Integrated Voltage Measurement... 16:43:46 Voltage Offset Correction: v_off_ini = -101.049 uV, v_off_fin = -94.794 uV 16:43:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.767 uVs 16:43:46 Integrated Voltage Measurement... 16:43:55 Voltage Offset Correction: v_off_ini = -88.120 uV, v_off_fin = -99.853 uV 16:43:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.255 uVs 16:43:55 Integrated Voltage Measurement... 16:44:04 Voltage Offset Correction: v_off_ini = -72.776 uV, v_off_fin = -69.149 uV 16:44:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.959 uVs 16:44:04 Integrated Voltage Measurement... 16:44:13 Voltage Offset Correction: v_off_ini = -73.882 uV, v_off_fin = -79.898 uV 16:44:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -132.118 uVs 16:44:13 Integrated Voltage Measurement... 16:44:22 Voltage Offset Correction: v_off_ini = -89.343 uV, v_off_fin = -84.121 uV 16:44:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.928 uVs 16:44:25 I2X Average and RMS of Measurements VT = -134.740 +- 2.300 uVs I2X = 12.396 +- 0.212 uTm^2 16:44:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:44:32 Integrated Voltage Measurement... 16:44:41 Voltage Offset Correction: v_off_ini = -73.528 uV, v_off_fin = -74.106 uV 16:44:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -216.421 uVs 16:44:41 Integrated Voltage Measurement... 16:44:50 Voltage Offset Correction: v_off_ini = -71.270 uV, v_off_fin = -81.826 uV 16:44:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.807 uVs 16:44:50 Integrated Voltage Measurement... 16:44:59 Voltage Offset Correction: v_off_ini = -96.755 uV, v_off_fin = -93.197 uV 16:44:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.674 uVs 16:44:59 Integrated Voltage Measurement... 16:45:08 Voltage Offset Correction: v_off_ini = -92.794 uV, v_off_fin = -87.294 uV 16:45:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.354 uVs 16:45:09 Integrated Voltage Measurement... 16:45:17 Voltage Offset Correction: v_off_ini = -77.671 uV, v_off_fin = -85.324 uV 16:45:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.672 uVs 16:45:18 Integrated Voltage Measurement... 16:45:26 Voltage Offset Correction: v_off_ini = -71.329 uV, v_off_fin = -71.365 uV 16:45:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.142 uVs 16:45:29 I2Y Average and RMS of Measurements VT = -220.012 +- 9.129 uVs I2Y = -20.241 +- 0.840 uTm^2 16:45:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:45:44 Integrated Voltage Measurement... 16:45:53 Voltage Offset Correction: v_off_ini = -90.827 uV, v_off_fin = -90.191 uV 16:45:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.232 uVs 16:45:53 Integrated Voltage Measurement... 16:46:02 Voltage Offset Correction: v_off_ini = -75.995 uV, v_off_fin = -69.566 uV 16:46:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.886 uVs 16:46:02 Integrated Voltage Measurement... 16:46:11 Voltage Offset Correction: v_off_ini = -75.104 uV, v_off_fin = -94.983 uV 16:46:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.634 uVs 16:46:11 Integrated Voltage Measurement... 16:46:20 Voltage Offset Correction: v_off_ini = -80.570 uV, v_off_fin = -83.483 uV 16:46:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.764 uVs 16:46:20 Integrated Voltage Measurement... 16:46:29 Voltage Offset Correction: v_off_ini = -89.557 uV, v_off_fin = -93.486 uV 16:46:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.827 uVs 16:46:29 Integrated Voltage Measurement... 16:46:38 Voltage Offset Correction: v_off_ini = -78.499 uV, v_off_fin = -87.374 uV 16:46:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.580 uVs 16:46:42 I1X Average and RMS of Measurements VT = -130.654 +- 6.786 uVs I1X = 26.131 +- 1.357 uTm 16:46:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:46:49 Integrated Voltage Measurement... 16:46:58 Voltage Offset Correction: v_off_ini = -77.421 uV, v_off_fin = -79.554 uV 16:46:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -132.177 uVs 16:46:58 Integrated Voltage Measurement... 16:47:07 Voltage Offset Correction: v_off_ini = -73.817 uV, v_off_fin = -76.373 uV 16:47:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 139.627 uVs 16:47:07 Integrated Voltage Measurement... 16:47:16 Voltage Offset Correction: v_off_ini = -70.313 uV, v_off_fin = -85.225 uV 16:47:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -127.706 uVs 16:47:16 Integrated Voltage Measurement... 16:47:25 Voltage Offset Correction: v_off_ini = -72.551 uV, v_off_fin = -71.405 uV 16:47:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 137.609 uVs 16:47:25 Integrated Voltage Measurement... 16:47:34 Voltage Offset Correction: v_off_ini = -74.905 uV, v_off_fin = -88.851 uV 16:47:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -137.638 uVs 16:47:34 Integrated Voltage Measurement... 16:47:43 Voltage Offset Correction: v_off_ini = -72.696 uV, v_off_fin = -76.525 uV 16:47:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 140.820 uVs 16:47:47 I1Y Average and RMS of Measurements VT = -135.930 +- 2.683 uVs I1Y = -27.185 +- 0.536 uTm 16:47:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:47:55 Integrated Voltage Measurement... 16:48:04 Voltage Offset Correction: v_off_ini = -66.892 uV, v_off_fin = -79.003 uV 16:48:04 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -148.558 uVs 16:48:04 Integrated Voltage Measurement... 16:48:13 Voltage Offset Correction: v_off_ini = -73.880 uV, v_off_fin = -60.599 uV 16:48:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.218 uVs 16:48:13 Integrated Voltage Measurement... 16:48:22 Voltage Offset Correction: v_off_ini = -79.799 uV, v_off_fin = -83.417 uV 16:48:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.652 uVs 16:48:22 Integrated Voltage Measurement... 16:48:31 Voltage Offset Correction: v_off_ini = -76.667 uV, v_off_fin = -57.427 uV 16:48:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.216 uVs 16:48:31 Integrated Voltage Measurement... 16:48:40 Voltage Offset Correction: v_off_ini = -68.952 uV, v_off_fin = -74.519 uV 16:48:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.307 uVs 16:48:40 Integrated Voltage Measurement... 16:48:49 Voltage Offset Correction: v_off_ini = -63.570 uV, v_off_fin = -47.240 uV 16:48:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.865 uVs 16:48:51 I2X Average and RMS of Measurements VT = -122.469 +- 8.984 uVs I2X = 11.267 +- 0.826 uTm^2 16:48:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:48:59 Integrated Voltage Measurement... 16:49:08 Voltage Offset Correction: v_off_ini = -69.187 uV, v_off_fin = -57.098 uV 16:49:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.872 uVs 16:49:08 Integrated Voltage Measurement... 16:49:17 Voltage Offset Correction: v_off_ini = -65.651 uV, v_off_fin = -61.812 uV 16:49:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.659 uVs 16:49:17 Integrated Voltage Measurement... 16:49:26 Voltage Offset Correction: v_off_ini = -61.039 uV, v_off_fin = -58.939 uV 16:49:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.912 uVs 16:49:26 Integrated Voltage Measurement... 16:49:35 Voltage Offset Correction: v_off_ini = -64.804 uV, v_off_fin = -55.093 uV 16:49:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.194 uVs 16:49:35 Integrated Voltage Measurement... 16:49:44 Voltage Offset Correction: v_off_ini = -47.132 uV, v_off_fin = -63.589 uV 16:49:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.419 uVs 16:49:44 Integrated Voltage Measurement... 16:49:53 Voltage Offset Correction: v_off_ini = -56.692 uV, v_off_fin = -55.753 uV 16:49:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.582 uVs 16:49:55 I2Y Average and RMS of Measurements VT = -221.273 +- 7.430 uVs I2Y = -20.357 +- 0.684 uTm^2 16:50:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:50:11 Integrated Voltage Measurement... 16:50:20 Voltage Offset Correction: v_off_ini = -71.575 uV, v_off_fin = -75.610 uV 16:50:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.981 uVs 16:50:20 Integrated Voltage Measurement... 16:50:29 Voltage Offset Correction: v_off_ini = -80.131 uV, v_off_fin = -78.705 uV 16:50:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.876 uVs 16:50:29 Integrated Voltage Measurement... 16:50:38 Voltage Offset Correction: v_off_ini = -84.342 uV, v_off_fin = -75.074 uV 16:50:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.688 uVs 16:50:38 Integrated Voltage Measurement... 16:50:47 Voltage Offset Correction: v_off_ini = -74.216 uV, v_off_fin = -66.830 uV 16:50:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.422 uVs 16:50:47 Integrated Voltage Measurement... 16:50:56 Voltage Offset Correction: v_off_ini = -71.642 uV, v_off_fin = -80.547 uV 16:50:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.364 uVs 16:50:56 Integrated Voltage Measurement... 16:51:05 Voltage Offset Correction: v_off_ini = -73.356 uV, v_off_fin = -74.834 uV 16:51:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.966 uVs 16:51:10 I1X Average and RMS of Measurements VT = -144.049 +- 10.587 uVs I1X = 28.810 +- 2.117 uTm 16:51:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:16 Integrated Voltage Measurement... 16:51:25 Voltage Offset Correction: v_off_ini = -67.628 uV, v_off_fin = -76.539 uV 16:51:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.292 uVs 16:51:25 Integrated Voltage Measurement... 16:51:34 Voltage Offset Correction: v_off_ini = -73.153 uV, v_off_fin = -53.317 uV 16:51:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 136.999 uVs 16:51:34 Integrated Voltage Measurement... 16:51:43 Voltage Offset Correction: v_off_ini = -51.652 uV, v_off_fin = -71.094 uV 16:51:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -131.249 uVs 16:51:43 Integrated Voltage Measurement... 16:51:52 Voltage Offset Correction: v_off_ini = -50.935 uV, v_off_fin = -53.036 uV 16:51:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 137.121 uVs 16:51:52 Integrated Voltage Measurement... 16:52:01 Voltage Offset Correction: v_off_ini = -63.073 uV, v_off_fin = -84.093 uV 16:52:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -124.293 uVs 16:52:01 Integrated Voltage Measurement... 16:52:10 Voltage Offset Correction: v_off_ini = -54.269 uV, v_off_fin = -58.167 uV 16:52:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 131.176 uVs 16:52:15 I1Y Average and RMS of Measurements VT = -132.688 +- 3.593 uVs I1Y = -26.537 +- 0.719 uTm 16:52:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:52:22 Integrated Voltage Measurement... 16:52:31 Voltage Offset Correction: v_off_ini = -77.797 uV, v_off_fin = -79.857 uV 16:52:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -151.632 uVs 16:52:31 Integrated Voltage Measurement... 16:52:40 Voltage Offset Correction: v_off_ini = -67.748 uV, v_off_fin = -64.853 uV 16:52:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.764 uVs 16:52:40 Integrated Voltage Measurement... 16:52:49 Voltage Offset Correction: v_off_ini = -70.655 uV, v_off_fin = -88.412 uV 16:52:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.242 uVs 16:52:49 Integrated Voltage Measurement... 16:52:58 Voltage Offset Correction: v_off_ini = -77.358 uV, v_off_fin = -67.178 uV 16:52:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.933 uVs 16:52:58 Integrated Voltage Measurement... 16:53:07 Voltage Offset Correction: v_off_ini = -84.476 uV, v_off_fin = -78.292 uV 16:53:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.251 uVs 16:53:07 Integrated Voltage Measurement... 16:53:16 Voltage Offset Correction: v_off_ini = -72.053 uV, v_off_fin = -64.942 uV 16:53:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.825 uVs 16:53:19 I2X Average and RMS of Measurements VT = -139.775 +- 3.953 uVs I2X = 12.859 +- 0.364 uTm^2 16:53:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:53:26 Integrated Voltage Measurement... 16:53:35 Voltage Offset Correction: v_off_ini = -68.924 uV, v_off_fin = -61.153 uV 16:53:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -210.268 uVs 16:53:35 Integrated Voltage Measurement... 16:53:44 Voltage Offset Correction: v_off_ini = -74.460 uV, v_off_fin = -61.225 uV 16:53:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.912 uVs 16:53:44 Integrated Voltage Measurement... 16:53:53 Voltage Offset Correction: v_off_ini = -60.304 uV, v_off_fin = -70.846 uV 16:53:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.307 uVs 16:53:53 Integrated Voltage Measurement... 16:54:02 Voltage Offset Correction: v_off_ini = -55.099 uV, v_off_fin = -52.418 uV 16:54:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.485 uVs 16:54:03 Integrated Voltage Measurement... 16:54:11 Voltage Offset Correction: v_off_ini = -63.786 uV, v_off_fin = -72.064 uV 16:54:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.530 uVs 16:54:12 Integrated Voltage Measurement... 16:54:20 Voltage Offset Correction: v_off_ini = -68.137 uV, v_off_fin = -72.618 uV 16:54:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.507 uVs 16:54:23 I2Y Average and RMS of Measurements VT = -223.502 +- 3.040 uVs I2Y = -20.562 +- 0.280 uTm^2 16:54:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:54:39 Integrated Voltage Measurement... 16:54:48 Voltage Offset Correction: v_off_ini = -74.937 uV, v_off_fin = -84.127 uV 16:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.813 uVs 16:54:48 Integrated Voltage Measurement... 16:54:57 Voltage Offset Correction: v_off_ini = -67.121 uV, v_off_fin = -74.298 uV 16:54:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.959 uVs 16:54:57 Integrated Voltage Measurement... 16:55:06 Voltage Offset Correction: v_off_ini = -83.574 uV, v_off_fin = -89.758 uV 16:55:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.868 uVs 16:55:06 Integrated Voltage Measurement... 16:55:15 Voltage Offset Correction: v_off_ini = -103.813 uV, v_off_fin = -79.208 uV 16:55:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.286 uVs 16:55:15 Integrated Voltage Measurement... 16:55:24 Voltage Offset Correction: v_off_ini = -76.879 uV, v_off_fin = -95.349 uV 16:55:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -168.278 uVs 16:55:24 Integrated Voltage Measurement... 16:55:33 Voltage Offset Correction: v_off_ini = -84.754 uV, v_off_fin = -73.855 uV 16:55:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.461 uVs 16:55:37 I1X Average and RMS of Measurements VT = -151.278 +- 4.117 uVs I1X = 30.256 +- 0.823 uTm 16:55:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:55:44 Integrated Voltage Measurement... 16:55:53 Voltage Offset Correction: v_off_ini = -65.542 uV, v_off_fin = -76.740 uV 16:55:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -135.100 uVs 16:55:53 Integrated Voltage Measurement... 16:56:02 Voltage Offset Correction: v_off_ini = -81.455 uV, v_off_fin = -47.720 uV 16:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 145.495 uVs 16:56:02 Integrated Voltage Measurement... 16:56:11 Voltage Offset Correction: v_off_ini = -62.456 uV, v_off_fin = -72.417 uV 16:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -132.827 uVs 16:56:11 Integrated Voltage Measurement... 16:56:20 Voltage Offset Correction: v_off_ini = -64.565 uV, v_off_fin = -42.058 uV 16:56:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 145.132 uVs 16:56:20 Integrated Voltage Measurement... 16:56:29 Voltage Offset Correction: v_off_ini = -45.594 uV, v_off_fin = -59.626 uV 16:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -114.448 uVs 16:56:29 Integrated Voltage Measurement... 16:56:38 Voltage Offset Correction: v_off_ini = -44.375 uV, v_off_fin = -25.816 uV 16:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 128.114 uVs 16:56:42 I1Y Average and RMS of Measurements VT = -133.519 +- 8.671 uVs I1Y = -26.703 +- 1.735 uTm 16:56:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:56:50 Integrated Voltage Measurement... 16:56:59 Voltage Offset Correction: v_off_ini = -64.366 uV, v_off_fin = -74.847 uV 16:56:59 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -152.828 uVs 16:56:59 Integrated Voltage Measurement... 16:57:08 Voltage Offset Correction: v_off_ini = -76.052 uV, v_off_fin = -76.213 uV 16:57:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.418 uVs 16:57:08 Integrated Voltage Measurement... 16:57:17 Voltage Offset Correction: v_off_ini = -89.414 uV, v_off_fin = -94.227 uV 16:57:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -156.930 uVs 16:57:17 Integrated Voltage Measurement... 16:57:26 Voltage Offset Correction: v_off_ini = -81.423 uV, v_off_fin = -54.864 uV 16:57:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 139.791 uVs 16:57:26 Integrated Voltage Measurement... 16:57:35 Voltage Offset Correction: v_off_ini = -66.468 uV, v_off_fin = -74.229 uV 16:57:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -145.744 uVs 16:57:35 Integrated Voltage Measurement... 16:57:44 Voltage Offset Correction: v_off_ini = -61.007 uV, v_off_fin = -51.795 uV 16:57:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 135.657 uVs 16:57:46 I2X Average and RMS of Measurements VT = -144.728 +- 3.140 uVs I2X = 13.315 +- 0.289 uTm^2 16:57:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:57:54 Integrated Voltage Measurement... 16:58:03 Voltage Offset Correction: v_off_ini = -59.982 uV, v_off_fin = -75.452 uV 16:58:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -195.871 uVs 16:58:03 Integrated Voltage Measurement... 16:58:12 Voltage Offset Correction: v_off_ini = -74.400 uV, v_off_fin = -62.764 uV 16:58:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.359 uVs 16:58:12 Integrated Voltage Measurement... 16:58:21 Voltage Offset Correction: v_off_ini = -57.511 uV, v_off_fin = -75.398 uV 16:58:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.704 uVs 16:58:21 Integrated Voltage Measurement... 16:58:30 Voltage Offset Correction: v_off_ini = -48.555 uV, v_off_fin = -52.239 uV 16:58:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.421 uVs 16:58:30 Integrated Voltage Measurement... 16:58:39 Voltage Offset Correction: v_off_ini = -60.735 uV, v_off_fin = -46.107 uV 16:58:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -193.758 uVs 16:58:39 Integrated Voltage Measurement... 16:58:48 Voltage Offset Correction: v_off_ini = -54.964 uV, v_off_fin = -42.613 uV 16:58:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.501 uVs 16:58:50 I2Y Average and RMS of Measurements VT = -200.769 +- 3.375 uVs I2Y = -18.471 +- 0.310 uTm^2 16:59:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:09 Integrated Voltage Measurement... 16:59:18 Voltage Offset Correction: v_off_ini = -60.881 uV, v_off_fin = -62.786 uV 16:59:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.242 uVs 16:59:18 Integrated Voltage Measurement... 16:59:27 Voltage Offset Correction: v_off_ini = -64.312 uV, v_off_fin = -55.655 uV 16:59:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.767 uVs 16:59:27 Integrated Voltage Measurement... 16:59:36 Voltage Offset Correction: v_off_ini = -64.369 uV, v_off_fin = -52.458 uV 16:59:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.847 uVs 16:59:36 Integrated Voltage Measurement... 16:59:45 Voltage Offset Correction: v_off_ini = -53.507 uV, v_off_fin = -41.717 uV 16:59:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.891 uVs 16:59:45 Integrated Voltage Measurement... 16:59:54 Voltage Offset Correction: v_off_ini = -48.272 uV, v_off_fin = -68.740 uV 16:59:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.828 uVs 16:59:54 Integrated Voltage Measurement... 17:00:03 Voltage Offset Correction: v_off_ini = -54.403 uV, v_off_fin = -41.069 uV 17:00:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.174 uVs 17:00:07 I1X Average and RMS of Measurements VT = -144.791 +- 6.495 uVs I1X = 28.958 +- 1.299 uTm 17:00:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:00:14 Integrated Voltage Measurement... 17:00:23 Voltage Offset Correction: v_off_ini = -59.746 uV, v_off_fin = -66.052 uV 17:00:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -127.741 uVs 17:00:23 Integrated Voltage Measurement... 17:00:32 Voltage Offset Correction: v_off_ini = -46.546 uV, v_off_fin = -55.819 uV 17:00:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.843 uVs 17:00:32 Integrated Voltage Measurement... 17:00:41 Voltage Offset Correction: v_off_ini = -48.693 uV, v_off_fin = -60.483 uV 17:00:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -137.056 uVs 17:00:41 Integrated Voltage Measurement... 17:00:50 Voltage Offset Correction: v_off_ini = -49.098 uV, v_off_fin = -35.823 uV 17:00:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = 128.216 uVs 17:00:50 Integrated Voltage Measurement... 17:00:59 Voltage Offset Correction: v_off_ini = -41.409 uV, v_off_fin = -55.377 uV 17:00:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.249 uVs 17:00:59 Integrated Voltage Measurement... 17:01:08 Voltage Offset Correction: v_off_ini = -42.340 uV, v_off_fin = -21.323 uV 17:01:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 148.880 uVs 17:01:12 I1Y Average and RMS of Measurements VT = -137.831 +- 3.909 uVs I1Y = -27.568 +- 0.779 uTm 17:01:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:20 Integrated Voltage Measurement... 17:01:28 Voltage Offset Correction: v_off_ini = -10.644 uV, v_off_fin = -19.025 uV 17:01:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -156.741 uVs 17:01:29 Integrated Voltage Measurement... 17:01:38 Voltage Offset Correction: v_off_ini = -4.524 uV, v_off_fin = 5.380 uV 17:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 125.715 uVs 17:01:38 Integrated Voltage Measurement... 17:01:47 Voltage Offset Correction: v_off_ini = 14.557 uV, v_off_fin = -9.749 uV 17:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -137.345 uVs 17:01:47 Integrated Voltage Measurement... 17:01:56 Voltage Offset Correction: v_off_ini = -5.892 uV, v_off_fin = 2.014 uV 17:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.390 uVs 17:01:56 Integrated Voltage Measurement... 17:02:05 Voltage Offset Correction: v_off_ini = -2.004 uV, v_off_fin = -7.748 uV 17:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -138.559 uVs 17:02:05 Integrated Voltage Measurement... 17:02:14 Voltage Offset Correction: v_off_ini = -3.552 uV, v_off_fin = -1.256 uV 17:02:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.239 uVs 17:02:16 I2X Average and RMS of Measurements VT = -139.998 +- 0.966 uVs I2X = 12.879 +- 0.088 uTm^2 17:02:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:24 Integrated Voltage Measurement... 17:02:33 Voltage Offset Correction: v_off_ini = -11.911 uV, v_off_fin = -0.277 uV 17:02:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -200.767 uVs 17:02:33 Integrated Voltage Measurement... 17:02:42 Voltage Offset Correction: v_off_ini = -20.339 uV, v_off_fin = -10.283 uV 17:02:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.644 uVs 17:02:42 Integrated Voltage Measurement... 17:02:51 Voltage Offset Correction: v_off_ini = 1.292 uV, v_off_fin = -6.241 uV 17:02:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -206.857 uVs 17:02:51 Integrated Voltage Measurement... 17:03:00 Voltage Offset Correction: v_off_ini = -4.056 uV, v_off_fin = -4.047 uV 17:03:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 221.286 uVs 17:03:00 Integrated Voltage Measurement... 17:03:09 Voltage Offset Correction: v_off_ini = 5.327 uV, v_off_fin = 18.146 uV 17:03:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.425 uVs 17:03:09 Integrated Voltage Measurement... 17:03:18 Voltage Offset Correction: v_off_ini = 28.951 uV, v_off_fin = 23.269 uV 17:03:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.219 uVs 17:03:20 I2Y Average and RMS of Measurements VT = -205.033 +- 8.408 uVs I2Y = -18.864 +- 0.774 uTm^2 17:03:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:03:39 Integrated Voltage Measurement... 17:03:48 Voltage Offset Correction: v_off_ini = 0.518 uV, v_off_fin = 5.581 uV 17:03:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -132.273 uVs 17:03:48 Integrated Voltage Measurement... 17:03:57 Voltage Offset Correction: v_off_ini = 1.855 uV, v_off_fin = 11.365 uV 17:03:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.362 uVs 17:03:57 Integrated Voltage Measurement... 17:04:06 Voltage Offset Correction: v_off_ini = 11.618 uV, v_off_fin = 11.788 uV 17:04:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.167 uVs 17:04:06 Integrated Voltage Measurement... 17:04:15 Voltage Offset Correction: v_off_ini = -5.544 uV, v_off_fin = -1.821 uV 17:04:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.462 uVs 17:04:15 Integrated Voltage Measurement... 17:04:24 Voltage Offset Correction: v_off_ini = 8.234 uV, v_off_fin = 13.379 uV 17:04:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.504 uVs 17:04:24 Integrated Voltage Measurement... 17:04:33 Voltage Offset Correction: v_off_ini = -1.248 uV, v_off_fin = 1.902 uV 17:04:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.752 uVs 17:04:37 I1X Average and RMS of Measurements VT = -142.753 +- 6.083 uVs I1X = 28.550 +- 1.217 uTm 17:04:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:04:44 Integrated Voltage Measurement... 17:04:52 Voltage Offset Correction: v_off_ini = 3.592 uV, v_off_fin = -12.093 uV 17:04:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -147.463 uVs 17:04:53 Integrated Voltage Measurement... 17:05:01 Voltage Offset Correction: v_off_ini = -3.716 uV, v_off_fin = 19.700 uV 17:05:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 147.962 uVs 17:05:02 Integrated Voltage Measurement... 17:05:10 Voltage Offset Correction: v_off_ini = 13.835 uV, v_off_fin = 2.929 uV 17:05:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -152.580 uVs 17:05:11 Integrated Voltage Measurement... 17:05:19 Voltage Offset Correction: v_off_ini = 13.972 uV, v_off_fin = 11.792 uV 17:05:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.504 uVs 17:05:20 Integrated Voltage Measurement... 17:05:28 Voltage Offset Correction: v_off_ini = 2.339 uV, v_off_fin = -12.615 uV 17:05:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -141.624 uVs 17:05:28 Integrated Voltage Measurement... 17:05:37 Voltage Offset Correction: v_off_ini = 6.445 uV, v_off_fin = 15.150 uV 17:05:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 159.058 uVs 17:05:42 I1Y Average and RMS of Measurements VT = -149.198 +- 1.100 uVs I1Y = -29.840 +- 0.218 uTm 17:05:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:05:49 Integrated Voltage Measurement... 17:05:58 Voltage Offset Correction: v_off_ini = 24.515 uV, v_off_fin = 16.304 uV 17:05:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -126.209 uVs 17:05:58 Integrated Voltage Measurement... 17:06:07 Voltage Offset Correction: v_off_ini = 15.211 uV, v_off_fin = 19.972 uV 17:06:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 140.240 uVs 17:06:07 Integrated Voltage Measurement... 17:06:16 Voltage Offset Correction: v_off_ini = 4.782 uV, v_off_fin = 1.806 uV 17:06:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.958 uVs 17:06:16 Integrated Voltage Measurement... 17:06:25 Voltage Offset Correction: v_off_ini = 3.890 uV, v_off_fin = 11.013 uV 17:06:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.059 uVs 17:06:25 Integrated Voltage Measurement... 17:06:34 Voltage Offset Correction: v_off_ini = -2.183 uV, v_off_fin = -15.843 uV 17:06:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.371 uVs 17:06:34 Integrated Voltage Measurement... 17:06:43 Voltage Offset Correction: v_off_ini = -2.373 uV, v_off_fin = 8.085 uV 17:06:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.195 uVs 17:06:46 I2X Average and RMS of Measurements VT = -133.839 +- 2.780 uVs I2X = 12.313 +- 0.256 uTm^2 17:06:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:06:54 Integrated Voltage Measurement... 17:07:02 Voltage Offset Correction: v_off_ini = -5.034 uV, v_off_fin = -9.519 uV 17:07:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -198.859 uVs 17:07:03 Integrated Voltage Measurement... 17:07:12 Voltage Offset Correction: v_off_ini = 15.464 uV, v_off_fin = 19.136 uV 17:07:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.658 uVs 17:07:12 Integrated Voltage Measurement... 17:07:21 Voltage Offset Correction: v_off_ini = 8.780 uV, v_off_fin = 15.485 uV 17:07:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.103 uVs 17:07:21 Integrated Voltage Measurement... 17:07:30 Voltage Offset Correction: v_off_ini = 32.040 uV, v_off_fin = 29.596 uV 17:07:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.198 uVs 17:07:30 Integrated Voltage Measurement... 17:07:39 Voltage Offset Correction: v_off_ini = 9.520 uV, v_off_fin = 17.352 uV 17:07:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.548 uVs 17:07:39 Integrated Voltage Measurement... 17:07:48 Voltage Offset Correction: v_off_ini = 10.576 uV, v_off_fin = 15.331 uV 17:07:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.420 uVs 17:07:50 I2Y Average and RMS of Measurements VT = -206.964 +- 3.783 uVs I2Y = -19.041 +- 0.348 uTm^2 17:08:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:08:08 Integrated Voltage Measurement... 17:08:17 Voltage Offset Correction: v_off_ini = 19.422 uV, v_off_fin = 11.752 uV 17:08:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -118.760 uVs 17:08:17 Integrated Voltage Measurement... 17:08:26 Voltage Offset Correction: v_off_ini = 18.727 uV, v_off_fin = 23.877 uV 17:08:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.612 uVs 17:08:26 Integrated Voltage Measurement... 17:08:35 Voltage Offset Correction: v_off_ini = 30.192 uV, v_off_fin = 9.227 uV 17:08:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.485 uVs 17:08:35 Integrated Voltage Measurement... 17:08:44 Voltage Offset Correction: v_off_ini = 19.625 uV, v_off_fin = 6.478 uV 17:08:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.110 uVs 17:08:44 Integrated Voltage Measurement... 17:08:53 Voltage Offset Correction: v_off_ini = 21.440 uV, v_off_fin = 11.872 uV 17:08:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.695 uVs 17:08:53 Integrated Voltage Measurement... 17:09:02 Voltage Offset Correction: v_off_ini = 6.899 uV, v_off_fin = 11.162 uV 17:09:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.013 uVs 17:09:07 I1X Average and RMS of Measurements VT = -138.279 +- 11.872 uVs I1X = 27.655 +- 2.375 uTm 17:09:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:09:13 Integrated Voltage Measurement... 17:09:22 Voltage Offset Correction: v_off_ini = 19.091 uV, v_off_fin = 4.770 uV 17:09:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4997 mm dXY = 0.4999 mm VT = -150.845 uVs 17:09:22 Integrated Voltage Measurement... 17:09:31 Voltage Offset Correction: v_off_ini = 19.208 uV, v_off_fin = 24.139 uV 17:09:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 173.371 uVs 17:09:31 Integrated Voltage Measurement... 17:09:40 Voltage Offset Correction: v_off_ini = 14.492 uV, v_off_fin = 10.957 uV 17:09:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -150.793 uVs 17:09:40 Integrated Voltage Measurement... 17:09:49 Voltage Offset Correction: v_off_ini = 19.851 uV, v_off_fin = 23.028 uV 17:09:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = 168.850 uVs 17:09:49 Integrated Voltage Measurement... 17:09:58 Voltage Offset Correction: v_off_ini = 10.354 uV, v_off_fin = -1.401 uV 17:09:58 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -144.189 uVs 17:09:58 Integrated Voltage Measurement... 17:10:07 Voltage Offset Correction: v_off_ini = 15.882 uV, v_off_fin = 33.663 uV 17:10:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 156.982 uVs 17:10:11 I1Y Average and RMS of Measurements VT = -157.505 +- 4.981 uVs I1Y = -31.506 +- 0.999 uTm 17:10:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:10:19 Integrated Voltage Measurement... 17:10:28 Voltage Offset Correction: v_off_ini = 40.334 uV, v_off_fin = 24.649 uV 17:10:28 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -114.009 uVs 17:10:28 Integrated Voltage Measurement... 17:10:37 Voltage Offset Correction: v_off_ini = 23.782 uV, v_off_fin = 45.375 uV 17:10:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.051 uVs 17:10:37 Integrated Voltage Measurement... 17:10:46 Voltage Offset Correction: v_off_ini = 29.831 uV, v_off_fin = 13.727 uV 17:10:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -142.937 uVs 17:10:46 Integrated Voltage Measurement... 17:10:55 Voltage Offset Correction: v_off_ini = 10.714 uV, v_off_fin = 27.041 uV 17:10:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.557 uVs 17:10:55 Integrated Voltage Measurement... 17:11:04 Voltage Offset Correction: v_off_ini = 1.514 uV, v_off_fin = 4.723 uV 17:11:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -117.801 uVs 17:11:04 Integrated Voltage Measurement... 17:11:13 Voltage Offset Correction: v_off_ini = 21.945 uV, v_off_fin = 36.207 uV 17:11:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 128.646 uVs 17:11:16 I2X Average and RMS of Measurements VT = -123.333 +- 3.968 uVs I2X = 11.347 +- 0.365 uTm^2 17:11:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:11:23 Integrated Voltage Measurement... 17:11:32 Voltage Offset Correction: v_off_ini = 21.887 uV, v_off_fin = 26.163 uV 17:11:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -215.808 uVs 17:11:32 Integrated Voltage Measurement... 17:11:41 Voltage Offset Correction: v_off_ini = 34.807 uV, v_off_fin = 34.757 uV 17:11:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 212.329 uVs 17:11:41 Integrated Voltage Measurement... 17:11:50 Voltage Offset Correction: v_off_ini = 34.995 uV, v_off_fin = 17.278 uV 17:11:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.847 uVs 17:11:50 Integrated Voltage Measurement... 17:11:59 Voltage Offset Correction: v_off_ini = 23.468 uV, v_off_fin = 14.421 uV 17:11:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.918 uVs 17:11:59 Integrated Voltage Measurement... 17:12:08 Voltage Offset Correction: v_off_ini = 23.299 uV, v_off_fin = 19.488 uV 17:12:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.266 uVs 17:12:08 Integrated Voltage Measurement... 17:12:17 Voltage Offset Correction: v_off_ini = 29.132 uV, v_off_fin = 23.317 uV 17:12:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.416 uVs 17:12:20 I2Y Average and RMS of Measurements VT = -217.764 +- 2.799 uVs I2Y = -20.035 +- 0.257 uTm^2 17:12:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:12:38 Integrated Voltage Measurement... 17:12:47 Voltage Offset Correction: v_off_ini = 15.692 uV, v_off_fin = 22.639 uV 17:12:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -126.260 uVs 17:12:47 Integrated Voltage Measurement... 17:12:56 Voltage Offset Correction: v_off_ini = 29.632 uV, v_off_fin = 37.221 uV 17:12:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.056 uVs 17:12:56 Integrated Voltage Measurement... 17:13:05 Voltage Offset Correction: v_off_ini = 29.856 uV, v_off_fin = 15.855 uV 17:13:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.250 uVs 17:13:05 Integrated Voltage Measurement... 17:13:14 Voltage Offset Correction: v_off_ini = 6.518 uV, v_off_fin = 11.437 uV 17:13:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.306 uVs 17:13:14 Integrated Voltage Measurement... 17:13:23 Voltage Offset Correction: v_off_ini = -0.248 uV, v_off_fin = 5.644 uV 17:13:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.281 uVs 17:13:23 Integrated Voltage Measurement... 17:13:32 Voltage Offset Correction: v_off_ini = 11.259 uV, v_off_fin = 24.340 uV 17:13:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.661 uVs 17:13:36 I1X Average and RMS of Measurements VT = -127.803 +- 5.060 uVs I1X = 25.560 +- 1.011 uTm 17:13:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:13:43 Integrated Voltage Measurement... 17:13:52 Voltage Offset Correction: v_off_ini = 6.554 uV, v_off_fin = 3.264 uV 17:13:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -166.697 uVs 17:13:52 Integrated Voltage Measurement... 17:14:01 Voltage Offset Correction: v_off_ini = 20.952 uV, v_off_fin = 34.785 uV 17:14:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.479 uVs 17:14:01 Integrated Voltage Measurement... 17:14:10 Voltage Offset Correction: v_off_ini = 12.674 uV, v_off_fin = -0.426 uV 17:14:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -158.993 uVs 17:14:10 Integrated Voltage Measurement... 17:14:19 Voltage Offset Correction: v_off_ini = 21.059 uV, v_off_fin = 34.661 uV 17:14:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 176.836 uVs 17:14:19 Integrated Voltage Measurement... 17:14:28 Voltage Offset Correction: v_off_ini = 16.417 uV, v_off_fin = 8.366 uV 17:14:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -162.080 uVs 17:14:28 Integrated Voltage Measurement... 17:14:37 Voltage Offset Correction: v_off_ini = 23.153 uV, v_off_fin = 37.524 uV 17:14:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.737 uVs 17:14:41 I1Y Average and RMS of Measurements VT = -165.470 +- 2.290 uVs I1Y = -33.093 +- 0.457 uTm 17:14:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:14:49 Integrated Voltage Measurement... 17:14:58 Voltage Offset Correction: v_off_ini = 24.003 uV, v_off_fin = 23.359 uV 17:14:58 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -120.632 uVs 17:14:58 Integrated Voltage Measurement... 17:15:07 Voltage Offset Correction: v_off_ini = 27.291 uV, v_off_fin = 27.983 uV 17:15:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 127.276 uVs 17:15:07 Integrated Voltage Measurement... 17:15:16 Voltage Offset Correction: v_off_ini = 8.179 uV, v_off_fin = 25.249 uV 17:15:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.297 uVs 17:15:16 Integrated Voltage Measurement... 17:15:25 Voltage Offset Correction: v_off_ini = 27.785 uV, v_off_fin = 43.734 uV 17:15:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.579 uVs 17:15:25 Integrated Voltage Measurement... 17:15:34 Voltage Offset Correction: v_off_ini = 25.949 uV, v_off_fin = 13.033 uV 17:15:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -134.874 uVs 17:15:34 Integrated Voltage Measurement... 17:15:43 Voltage Offset Correction: v_off_ini = 27.339 uV, v_off_fin = 26.327 uV 17:15:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 126.882 uVs 17:15:45 I2X Average and RMS of Measurements VT = -124.757 +- 4.705 uVs I2X = 11.477 +- 0.433 uTm^2 17:15:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:15:53 Integrated Voltage Measurement... 17:16:02 Voltage Offset Correction: v_off_ini = 41.540 uV, v_off_fin = 28.290 uV 17:16:02 Integrated Voltage Measurement dXYus = 1.0002 mm, dXYds = 0.0000 mm dXY = 1.0002 mm VT = -198.780 uVs 17:16:02 Integrated Voltage Measurement... 17:16:11 Voltage Offset Correction: v_off_ini = 36.551 uV, v_off_fin = 44.255 uV 17:16:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.365 uVs 17:16:11 Integrated Voltage Measurement... 17:16:20 Voltage Offset Correction: v_off_ini = 41.496 uV, v_off_fin = 35.421 uV 17:16:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.753 uVs 17:16:20 Integrated Voltage Measurement... 17:16:29 Voltage Offset Correction: v_off_ini = 43.637 uV, v_off_fin = 43.933 uV 17:16:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.455 uVs 17:16:29 Integrated Voltage Measurement... 17:16:38 Voltage Offset Correction: v_off_ini = 38.574 uV, v_off_fin = 39.702 uV 17:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.760 uVs 17:16:38 Integrated Voltage Measurement... 17:16:47 Voltage Offset Correction: v_off_ini = 41.369 uV, v_off_fin = 45.182 uV 17:16:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.324 uVs 17:16:50 I2Y Average and RMS of Measurements VT = -206.906 +- 6.777 uVs I2Y = -19.035 +- 0.624 uTm^2 17:17:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:17:08 Integrated Voltage Measurement... 17:17:17 Voltage Offset Correction: v_off_ini = 45.661 uV, v_off_fin = 45.723 uV 17:17:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = -116.859 uVs 17:17:17 Integrated Voltage Measurement... 17:17:26 Voltage Offset Correction: v_off_ini = 43.700 uV, v_off_fin = 45.317 uV 17:17:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.750 uVs 17:17:26 Integrated Voltage Measurement... 17:17:35 Voltage Offset Correction: v_off_ini = 36.436 uV, v_off_fin = 30.647 uV 17:17:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.380 uVs 17:17:35 Integrated Voltage Measurement... 17:17:44 Voltage Offset Correction: v_off_ini = 45.948 uV, v_off_fin = 47.091 uV 17:17:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.470 uVs 17:17:44 Integrated Voltage Measurement... 17:17:53 Voltage Offset Correction: v_off_ini = 37.603 uV, v_off_fin = 41.902 uV 17:17:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.494 uVs 17:17:53 Integrated Voltage Measurement... 17:18:02 Voltage Offset Correction: v_off_ini = 39.592 uV, v_off_fin = 47.946 uV 17:18:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.575 uVs 17:18:06 I1X Average and RMS of Measurements VT = -120.422 +- 6.452 uVs I1X = 24.084 +- 1.291 uTm 17:18:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:18:13 Integrated Voltage Measurement... 17:18:22 Voltage Offset Correction: v_off_ini = 19.426 uV, v_off_fin = 10.764 uV 17:18:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.505 uVs 17:18:22 Integrated Voltage Measurement... 17:18:31 Voltage Offset Correction: v_off_ini = 27.224 uV, v_off_fin = 37.766 uV 17:18:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 175.996 uVs 17:18:31 Integrated Voltage Measurement... 17:18:40 Voltage Offset Correction: v_off_ini = 23.119 uV, v_off_fin = 2.207 uV 17:18:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.728 uVs 17:18:40 Integrated Voltage Measurement... 17:18:49 Voltage Offset Correction: v_off_ini = 11.840 uV, v_off_fin = 25.599 uV 17:18:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.605 uVs 17:18:49 Integrated Voltage Measurement... 17:18:58 Voltage Offset Correction: v_off_ini = 12.426 uV, v_off_fin = 7.523 uV 17:18:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.018 uVs 17:18:58 Integrated Voltage Measurement... 17:19:07 Voltage Offset Correction: v_off_ini = 13.624 uV, v_off_fin = 27.887 uV 17:19:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 196.295 uVs 17:19:11 I1Y Average and RMS of Measurements VT = -174.191 +- 1.767 uVs I1Y = -34.836 +- 0.354 uTm 17:19:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:19:19 Integrated Voltage Measurement... 17:19:28 Voltage Offset Correction: v_off_ini = 17.554 uV, v_off_fin = 6.224 uV 17:19:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -133.836 uVs 17:19:28 Integrated Voltage Measurement... 17:19:37 Voltage Offset Correction: v_off_ini = 13.079 uV, v_off_fin = 30.327 uV 17:19:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 116.257 uVs 17:19:37 Integrated Voltage Measurement... 17:19:46 Voltage Offset Correction: v_off_ini = 9.978 uV, v_off_fin = -2.766 uV 17:19:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.173 uVs 17:19:46 Integrated Voltage Measurement... 17:19:55 Voltage Offset Correction: v_off_ini = 16.891 uV, v_off_fin = 19.634 uV 17:19:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 118.849 uVs 17:19:55 Integrated Voltage Measurement... 17:20:04 Voltage Offset Correction: v_off_ini = 16.704 uV, v_off_fin = 7.887 uV 17:20:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.986 uVs 17:20:04 Integrated Voltage Measurement... 17:20:13 Voltage Offset Correction: v_off_ini = 15.627 uV, v_off_fin = 32.081 uV 17:20:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.203 uVs 17:20:15 I2X Average and RMS of Measurements VT = -124.217 +- 1.207 uVs I2X = 11.428 +- 0.111 uTm^2 17:20:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:20:23 Integrated Voltage Measurement... 17:20:32 Voltage Offset Correction: v_off_ini = 19.418 uV, v_off_fin = 37.498 uV 17:20:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -212.453 uVs 17:20:32 Integrated Voltage Measurement... 17:20:41 Voltage Offset Correction: v_off_ini = 37.667 uV, v_off_fin = 34.629 uV 17:20:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 225.890 uVs 17:20:41 Integrated Voltage Measurement... 17:20:50 Voltage Offset Correction: v_off_ini = 32.613 uV, v_off_fin = 30.149 uV 17:20:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.992 uVs 17:20:50 Integrated Voltage Measurement... 17:20:59 Voltage Offset Correction: v_off_ini = 29.182 uV, v_off_fin = 27.498 uV 17:20:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 238.259 uVs 17:20:59 Integrated Voltage Measurement... 17:21:08 Voltage Offset Correction: v_off_ini = -0.385 uV, v_off_fin = 2.354 uV 17:21:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.813 uVs 17:21:08 Integrated Voltage Measurement... 17:21:17 Voltage Offset Correction: v_off_ini = 5.919 uV, v_off_fin = 19.344 uV 17:21:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.924 uVs 17:21:19 I2Y Average and RMS of Measurements VT = -220.889 +- 10.585 uVs I2Y = -20.322 +- 0.974 uTm^2 17:21:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:38 Integrated Voltage Measurement... 17:21:47 Voltage Offset Correction: v_off_ini = 20.577 uV, v_off_fin = 10.219 uV 17:21:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.090 uVs 17:21:47 Integrated Voltage Measurement... 17:21:56 Voltage Offset Correction: v_off_ini = 17.086 uV, v_off_fin = 33.500 uV 17:21:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.256 uVs 17:21:56 Integrated Voltage Measurement... 17:22:05 Voltage Offset Correction: v_off_ini = 23.930 uV, v_off_fin = 27.682 uV 17:22:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.131 uVs 17:22:05 Integrated Voltage Measurement... 17:22:14 Voltage Offset Correction: v_off_ini = 14.931 uV, v_off_fin = 14.932 uV 17:22:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.682 uVs 17:22:14 Integrated Voltage Measurement... 17:22:23 Voltage Offset Correction: v_off_ini = 8.738 uV, v_off_fin = 9.350 uV 17:22:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.843 uVs 17:22:23 Integrated Voltage Measurement... 17:22:32 Voltage Offset Correction: v_off_ini = 12.732 uV, v_off_fin = 14.280 uV 17:22:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.508 uVs 17:22:36 I1X Average and RMS of Measurements VT = -120.252 +- 5.006 uVs I1X = 24.050 +- 1.001 uTm 17:22:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:43 Integrated Voltage Measurement... 17:22:52 Voltage Offset Correction: v_off_ini = 4.916 uV, v_off_fin = -6.691 uV 17:22:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -188.073 uVs 17:22:52 Integrated Voltage Measurement... 17:23:01 Voltage Offset Correction: v_off_ini = -5.661 uV, v_off_fin = -1.587 uV 17:23:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 195.626 uVs 17:23:01 Integrated Voltage Measurement... 17:23:10 Voltage Offset Correction: v_off_ini = 5.573 uV, v_off_fin = -10.885 uV 17:23:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -178.842 uVs 17:23:10 Integrated Voltage Measurement... 17:23:19 Voltage Offset Correction: v_off_ini = -8.523 uV, v_off_fin = 4.660 uV 17:23:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 191.176 uVs 17:23:19 Integrated Voltage Measurement... 17:23:28 Voltage Offset Correction: v_off_ini = -8.537 uV, v_off_fin = -10.035 uV 17:23:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -181.813 uVs 17:23:28 Integrated Voltage Measurement... 17:23:37 Voltage Offset Correction: v_off_ini = 20.297 uV, v_off_fin = 2.863 uV 17:23:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 178.370 uVs 17:23:41 I1Y Average and RMS of Measurements VT = -185.650 +- 4.822 uVs I1Y = -37.129 +- 0.964 uTm 17:23:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:23:49 Integrated Voltage Measurement... 17:23:58 Voltage Offset Correction: v_off_ini = 9.827 uV, v_off_fin = -12.710 uV 17:23:58 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -123.598 uVs 17:23:58 Integrated Voltage Measurement... 17:24:07 Voltage Offset Correction: v_off_ini = 14.499 uV, v_off_fin = 22.651 uV 17:24:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.357 uVs 17:24:07 Integrated Voltage Measurement... 17:24:16 Voltage Offset Correction: v_off_ini = 9.014 uV, v_off_fin = -2.900 uV 17:24:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.800 uVs 17:24:16 Integrated Voltage Measurement... 17:24:25 Voltage Offset Correction: v_off_ini = 20.000 uV, v_off_fin = 30.864 uV 17:24:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.845 uVs 17:24:25 Integrated Voltage Measurement... 17:24:34 Voltage Offset Correction: v_off_ini = 19.051 uV, v_off_fin = 0.562 uV 17:24:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.783 uVs 17:24:34 Integrated Voltage Measurement... 17:24:43 Voltage Offset Correction: v_off_ini = 9.805 uV, v_off_fin = 9.096 uV 17:24:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.836 uVs 17:24:45 I2X Average and RMS of Measurements VT = -114.036 +- 3.360 uVs I2X = 10.491 +- 0.309 uTm^2 17:24:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:53 Integrated Voltage Measurement... 17:25:02 Voltage Offset Correction: v_off_ini = 8.408 uV, v_off_fin = 4.387 uV 17:25:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.412 uVs 17:25:02 Integrated Voltage Measurement... 17:25:11 Voltage Offset Correction: v_off_ini = 19.147 uV, v_off_fin = 18.367 uV 17:25:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.610 uVs 17:25:11 Integrated Voltage Measurement... 17:25:20 Voltage Offset Correction: v_off_ini = 8.739 uV, v_off_fin = 12.855 uV 17:25:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.009 uVs 17:25:20 Integrated Voltage Measurement... 17:25:29 Voltage Offset Correction: v_off_ini = 14.709 uV, v_off_fin = 8.850 uV 17:25:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.149 uVs 17:25:29 Integrated Voltage Measurement... 17:25:38 Voltage Offset Correction: v_off_ini = 6.429 uV, v_off_fin = 8.198 uV 17:25:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.333 uVs 17:25:38 Integrated Voltage Measurement... 17:25:47 Voltage Offset Correction: v_off_ini = 24.719 uV, v_off_fin = 25.579 uV 17:25:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.375 uVs 17:25:49 I2Y Average and RMS of Measurements VT = -215.148 +- 1.470 uVs I2Y = -19.794 +- 0.135 uTm^2 17:25:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm