SLAC Magnetic Measurements Date: 08-20-2025 Time: 12:26:41 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16343 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 12:27:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:27:42 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:27:44 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:27:45 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:27:47 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:29:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:40 Integrated Voltage Measurement... 12:29:49 Voltage Offset Correction: v_off_ini = -1559.937 uV, v_off_fin = -1549.019 uV 12:29:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.631 uVs 12:29:49 Integrated Voltage Measurement... 12:29:58 Voltage Offset Correction: v_off_ini = -1535.416 uV, v_off_fin = -1531.130 uV 12:29:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.916 uVs 12:29:58 Integrated Voltage Measurement... 12:30:07 Voltage Offset Correction: v_off_ini = -1551.330 uV, v_off_fin = -1555.501 uV 12:30:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.774 uVs 12:30:07 Integrated Voltage Measurement... 12:30:16 Voltage Offset Correction: v_off_ini = -1526.237 uV, v_off_fin = -1535.645 uV 12:30:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.790 uVs 12:30:16 Integrated Voltage Measurement... 12:30:25 Voltage Offset Correction: v_off_ini = -1548.320 uV, v_off_fin = -1541.369 uV 12:30:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.463 uVs 12:30:25 Integrated Voltage Measurement... 12:30:34 Voltage Offset Correction: v_off_ini = -1556.674 uV, v_off_fin = -1549.423 uV 12:30:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.960 uVs 12:30:38 I1X Average and RMS of Measurements VT = -113.256 +- 5.086 uVs I1X = 22.651 +- 1.017 uTm 12:30:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:45 Integrated Voltage Measurement... 12:30:54 Voltage Offset Correction: v_off_ini = -1524.371 uV, v_off_fin = -1538.720 uV 12:30:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.645 uVs 12:30:54 Integrated Voltage Measurement... 12:31:03 Voltage Offset Correction: v_off_ini = -1515.480 uV, v_off_fin = -1518.270 uV 12:31:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.862 uVs 12:31:03 Integrated Voltage Measurement... 12:31:12 Voltage Offset Correction: v_off_ini = -1520.660 uV, v_off_fin = -1522.284 uV 12:31:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.478 uVs 12:31:12 Integrated Voltage Measurement... 12:31:21 Voltage Offset Correction: v_off_ini = -1515.389 uV, v_off_fin = -1493.903 uV 12:31:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.443 uVs 12:31:21 Integrated Voltage Measurement... 12:31:30 Voltage Offset Correction: v_off_ini = -1508.946 uV, v_off_fin = -1508.828 uV 12:31:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.660 uVs 12:31:30 Integrated Voltage Measurement... 12:31:39 Voltage Offset Correction: v_off_ini = -1491.557 uV, v_off_fin = -1497.425 uV 12:31:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.266 uVs 12:31:43 I1Y Average and RMS of Measurements VT = -170.726 +- 1.559 uVs I1Y = -34.145 +- 0.312 uTm 12:31:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:51 Integrated Voltage Measurement... 12:32:00 Voltage Offset Correction: v_off_ini = -1496.374 uV, v_off_fin = -1491.550 uV 12:32:00 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -104.905 uVs 12:32:00 Integrated Voltage Measurement... 12:32:09 Voltage Offset Correction: v_off_ini = -1499.752 uV, v_off_fin = -1473.375 uV 12:32:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.177 uVs 12:32:09 Integrated Voltage Measurement... 12:32:18 Voltage Offset Correction: v_off_ini = -1483.406 uV, v_off_fin = -1478.880 uV 12:32:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -81.290 uVs 12:32:18 Integrated Voltage Measurement... 12:32:27 Voltage Offset Correction: v_off_ini = -1469.981 uV, v_off_fin = -1463.296 uV 12:32:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 84.042 uVs 12:32:27 Integrated Voltage Measurement... 12:32:36 Voltage Offset Correction: v_off_ini = -1476.254 uV, v_off_fin = -1479.108 uV 12:32:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -90.455 uVs 12:32:37 Integrated Voltage Measurement... 12:32:46 Voltage Offset Correction: v_off_ini = -1478.703 uV, v_off_fin = -1459.440 uV 12:32:46 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 76.258 uVs 12:32:48 I2X Average and RMS of Measurements VT = -87.188 +- 5.913 uVs I2X = 8.022 +- 0.543 uTm^2 12:32:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:32:56 Integrated Voltage Measurement... 12:33:05 Voltage Offset Correction: v_off_ini = -1464.659 uV, v_off_fin = -1452.209 uV 12:33:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -141.138 uVs 12:33:05 Integrated Voltage Measurement... 12:33:14 Voltage Offset Correction: v_off_ini = -1460.624 uV, v_off_fin = -1443.359 uV 12:33:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 140.746 uVs 12:33:14 Integrated Voltage Measurement... 12:33:23 Voltage Offset Correction: v_off_ini = -1454.780 uV, v_off_fin = -1451.192 uV 12:33:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -131.282 uVs 12:33:23 Integrated Voltage Measurement... 12:33:32 Voltage Offset Correction: v_off_ini = -1442.532 uV, v_off_fin = -1438.808 uV 12:33:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 141.846 uVs 12:33:32 Integrated Voltage Measurement... 12:33:41 Voltage Offset Correction: v_off_ini = -1439.473 uV, v_off_fin = -1436.276 uV 12:33:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -138.136 uVs 12:33:41 Integrated Voltage Measurement... 12:33:50 Voltage Offset Correction: v_off_ini = -1445.385 uV, v_off_fin = -1433.554 uV 12:33:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 142.063 uVs 12:33:52 I2Y Average and RMS of Measurements VT = -139.202 +- 1.897 uVs I2Y = -12.807 +- 0.175 uTm^2 12:34:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:34:07 Integrated Voltage Measurement... 12:34:16 Voltage Offset Correction: v_off_ini = -1434.593 uV, v_off_fin = -1418.954 uV 12:34:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.608 uVs 12:34:16 Integrated Voltage Measurement... 12:34:25 Voltage Offset Correction: v_off_ini = -1416.011 uV, v_off_fin = -1407.903 uV 12:34:25 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.712 uVs 12:34:25 Integrated Voltage Measurement... 12:34:34 Voltage Offset Correction: v_off_ini = -1408.273 uV, v_off_fin = -1416.028 uV 12:34:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -100.899 uVs 12:34:34 Integrated Voltage Measurement... 12:34:43 Voltage Offset Correction: v_off_ini = -1417.680 uV, v_off_fin = -1421.116 uV 12:34:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.760 uVs 12:34:43 Integrated Voltage Measurement... 12:34:52 Voltage Offset Correction: v_off_ini = -1399.375 uV, v_off_fin = -1410.500 uV 12:34:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.400 uVs 12:34:52 Integrated Voltage Measurement... 12:35:01 Voltage Offset Correction: v_off_ini = -1412.128 uV, v_off_fin = -1400.778 uV 12:35:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.679 uVs 12:35:05 I1X Average and RMS of Measurements VT = -95.010 +- 2.469 uVs I1X = 19.003 +- 0.494 uTm 12:35:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:35:12 Integrated Voltage Measurement... 12:35:21 Voltage Offset Correction: v_off_ini = -1397.522 uV, v_off_fin = -1397.774 uV 12:35:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.618 uVs 12:35:21 Integrated Voltage Measurement... 12:35:30 Voltage Offset Correction: v_off_ini = -1387.449 uV, v_off_fin = -1378.607 uV 12:35:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.728 uVs 12:35:30 Integrated Voltage Measurement... 12:35:39 Voltage Offset Correction: v_off_ini = -1403.823 uV, v_off_fin = -1409.757 uV 12:35:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.055 uVs 12:35:39 Integrated Voltage Measurement... 12:35:48 Voltage Offset Correction: v_off_ini = -1400.118 uV, v_off_fin = -1371.137 uV 12:35:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.122 uVs 12:35:48 Integrated Voltage Measurement... 12:35:57 Voltage Offset Correction: v_off_ini = -1363.368 uV, v_off_fin = -1379.705 uV 12:35:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.207 uVs 12:35:57 Integrated Voltage Measurement... 12:36:06 Voltage Offset Correction: v_off_ini = -1388.841 uV, v_off_fin = -1365.754 uV 12:36:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 166.554 uVs 12:36:10 I1Y Average and RMS of Measurements VT = -189.381 +- 8.489 uVs I1Y = -37.876 +- 1.698 uTm 12:36:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:36:18 Integrated Voltage Measurement... 12:36:27 Voltage Offset Correction: v_off_ini = -1369.984 uV, v_off_fin = -1385.102 uV 12:36:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -82.556 uVs 12:36:27 Integrated Voltage Measurement... 12:36:36 Voltage Offset Correction: v_off_ini = -1378.058 uV, v_off_fin = -1354.760 uV 12:36:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 62.658 uVs 12:36:36 Integrated Voltage Measurement... 12:36:45 Voltage Offset Correction: v_off_ini = -1351.025 uV, v_off_fin = -1360.767 uV 12:36:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.140 uVs 12:36:45 Integrated Voltage Measurement... 12:36:54 Voltage Offset Correction: v_off_ini = -1344.452 uV, v_off_fin = -1332.807 uV 12:36:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.443 uVs 12:36:54 Integrated Voltage Measurement... 12:37:03 Voltage Offset Correction: v_off_ini = -1330.320 uV, v_off_fin = -1350.703 uV 12:37:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.548 uVs 12:37:03 Integrated Voltage Measurement... 12:37:12 Voltage Offset Correction: v_off_ini = -1344.399 uV, v_off_fin = -1341.006 uV 12:37:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.664 uVs 12:37:15 I2X Average and RMS of Measurements VT = -78.668 +- 4.437 uVs I2X = 7.237 +- 0.408 uTm^2 12:37:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:37:22 Integrated Voltage Measurement... 12:37:31 Voltage Offset Correction: v_off_ini = -1336.187 uV, v_off_fin = -1341.142 uV 12:37:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -150.246 uVs 12:37:31 Integrated Voltage Measurement... 12:37:40 Voltage Offset Correction: v_off_ini = -1325.786 uV, v_off_fin = -1336.911 uV 12:37:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 161.412 uVs 12:37:40 Integrated Voltage Measurement... 12:37:49 Voltage Offset Correction: v_off_ini = -1338.571 uV, v_off_fin = -1337.425 uV 12:37:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -134.111 uVs 12:37:49 Integrated Voltage Measurement... 12:37:58 Voltage Offset Correction: v_off_ini = -1346.451 uV, v_off_fin = -1321.059 uV 12:37:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.578 uVs 12:37:58 Integrated Voltage Measurement... 12:38:07 Voltage Offset Correction: v_off_ini = -1324.150 uV, v_off_fin = -1316.755 uV 12:38:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.138 uVs 12:38:07 Integrated Voltage Measurement... 12:38:16 Voltage Offset Correction: v_off_ini = -1301.807 uV, v_off_fin = -1310.809 uV 12:38:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 152.149 uVs 12:38:19 I2Y Average and RMS of Measurements VT = -160.772 +- 4.728 uVs I2Y = -14.791 +- 0.435 uTm^2 12:38:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:34 Integrated Voltage Measurement... 12:38:43 Voltage Offset Correction: v_off_ini = -1293.789 uV, v_off_fin = -1301.266 uV 12:38:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.782 uVs 12:38:43 Integrated Voltage Measurement... 12:38:52 Voltage Offset Correction: v_off_ini = -1292.442 uV, v_off_fin = -1287.786 uV 12:38:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.320 uVs 12:38:52 Integrated Voltage Measurement... 12:39:01 Voltage Offset Correction: v_off_ini = -1293.204 uV, v_off_fin = -1295.187 uV 12:39:01 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.945 uVs 12:39:01 Integrated Voltage Measurement... 12:39:10 Voltage Offset Correction: v_off_ini = -1276.607 uV, v_off_fin = -1276.850 uV 12:39:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.480 uVs 12:39:10 Integrated Voltage Measurement... 12:39:19 Voltage Offset Correction: v_off_ini = -1279.330 uV, v_off_fin = -1275.934 uV 12:39:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.252 uVs 12:39:19 Integrated Voltage Measurement... 12:39:28 Voltage Offset Correction: v_off_ini = -1267.052 uV, v_off_fin = -1275.352 uV 12:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.313 uVs 12:39:32 I1X Average and RMS of Measurements VT = -86.682 +- 7.283 uVs I1X = 17.337 +- 1.456 uTm 12:39:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:39:39 Integrated Voltage Measurement... 12:39:47 Voltage Offset Correction: v_off_ini = -1289.422 uV, v_off_fin = -1285.289 uV 12:39:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.903 uVs 12:39:47 Integrated Voltage Measurement... 12:39:56 Voltage Offset Correction: v_off_ini = -1292.758 uV, v_off_fin = -1268.092 uV 12:39:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.673 uVs 12:39:56 Integrated Voltage Measurement... 12:40:05 Voltage Offset Correction: v_off_ini = -1261.012 uV, v_off_fin = -1274.805 uV 12:40:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.343 uVs 12:40:05 Integrated Voltage Measurement... 12:40:14 Voltage Offset Correction: v_off_ini = -1267.585 uV, v_off_fin = -1264.275 uV 12:40:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.634 uVs 12:40:14 Integrated Voltage Measurement... 12:40:23 Voltage Offset Correction: v_off_ini = -1249.771 uV, v_off_fin = -1272.253 uV 12:40:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.331 uVs 12:40:23 Integrated Voltage Measurement... 12:40:32 Voltage Offset Correction: v_off_ini = -1253.238 uV, v_off_fin = -1241.827 uV 12:40:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.892 uVs 12:40:37 I1Y Average and RMS of Measurements VT = -212.462 +- 3.216 uVs I1Y = -42.492 +- 0.643 uTm 12:40:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:40:44 Integrated Voltage Measurement... 12:40:53 Voltage Offset Correction: v_off_ini = -1236.275 uV, v_off_fin = -1248.249 uV 12:40:53 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -86.674 uVs 12:40:53 Integrated Voltage Measurement... 12:41:02 Voltage Offset Correction: v_off_ini = -1225.996 uV, v_off_fin = -1205.546 uV 12:41:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.795 uVs 12:41:02 Integrated Voltage Measurement... 12:41:11 Voltage Offset Correction: v_off_ini = -1222.607 uV, v_off_fin = -1212.409 uV 12:41:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.815 uVs 12:41:11 Integrated Voltage Measurement... 12:41:20 Voltage Offset Correction: v_off_ini = -1197.185 uV, v_off_fin = -1203.138 uV 12:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.162 uVs 12:41:20 Integrated Voltage Measurement... 12:41:29 Voltage Offset Correction: v_off_ini = -1215.941 uV, v_off_fin = -1234.310 uV 12:41:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.668 uVs 12:41:29 Integrated Voltage Measurement... 12:41:38 Voltage Offset Correction: v_off_ini = -1204.894 uV, v_off_fin = -1182.055 uV 12:41:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.924 uVs 12:41:41 I2X Average and RMS of Measurements VT = -75.173 +- 5.931 uVs I2X = 6.916 +- 0.545 uTm^2 12:41:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:48 Integrated Voltage Measurement... 12:41:57 Voltage Offset Correction: v_off_ini = -1196.352 uV, v_off_fin = -1191.145 uV 12:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.242 uVs 12:41:57 Integrated Voltage Measurement... 12:42:06 Voltage Offset Correction: v_off_ini = -1185.301 uV, v_off_fin = -1189.435 uV 12:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.872 uVs 12:42:06 Integrated Voltage Measurement... 12:42:15 Voltage Offset Correction: v_off_ini = -1184.060 uV, v_off_fin = -1191.397 uV 12:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.997 uVs 12:42:15 Integrated Voltage Measurement... 12:42:24 Voltage Offset Correction: v_off_ini = -1187.463 uV, v_off_fin = -1178.043 uV 12:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.546 uVs 12:42:24 Integrated Voltage Measurement... 12:42:33 Voltage Offset Correction: v_off_ini = -1181.118 uV, v_off_fin = -1182.497 uV 12:42:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.715 uVs 12:42:33 Integrated Voltage Measurement... 12:42:42 Voltage Offset Correction: v_off_ini = -1154.446 uV, v_off_fin = -1151.309 uV 12:42:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.794 uVs 12:42:45 I2Y Average and RMS of Measurements VT = -188.694 +- 6.474 uVs I2Y = -17.360 +- 0.596 uTm^2 12:42:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:43:00 Integrated Voltage Measurement... 12:43:09 Voltage Offset Correction: v_off_ini = -1140.163 uV, v_off_fin = -1157.099 uV 12:43:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.879 uVs 12:43:09 Integrated Voltage Measurement... 12:43:18 Voltage Offset Correction: v_off_ini = -1145.635 uV, v_off_fin = -1126.703 uV 12:43:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.541 uVs 12:43:18 Integrated Voltage Measurement... 12:43:27 Voltage Offset Correction: v_off_ini = -1149.576 uV, v_off_fin = -1148.582 uV 12:43:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.683 uVs 12:43:27 Integrated Voltage Measurement... 12:43:36 Voltage Offset Correction: v_off_ini = -1147.081 uV, v_off_fin = -1131.557 uV 12:43:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.470 uVs 12:43:36 Integrated Voltage Measurement... 12:43:45 Voltage Offset Correction: v_off_ini = -1145.405 uV, v_off_fin = -1143.470 uV 12:43:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.568 uVs 12:43:45 Integrated Voltage Measurement... 12:43:54 Voltage Offset Correction: v_off_ini = -1139.734 uV, v_off_fin = -1128.538 uV 12:43:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.330 uVs 12:43:58 I1X Average and RMS of Measurements VT = -80.912 +- 4.859 uVs I1X = 16.182 +- 0.972 uTm 12:44:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:44:05 Integrated Voltage Measurement... 12:44:13 Voltage Offset Correction: v_off_ini = -1126.543 uV, v_off_fin = -1135.733 uV 12:44:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.819 uVs 12:44:14 Integrated Voltage Measurement... 12:44:22 Voltage Offset Correction: v_off_ini = -1107.572 uV, v_off_fin = -1091.885 uV 12:44:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.798 uVs 12:44:23 Integrated Voltage Measurement... 12:44:31 Voltage Offset Correction: v_off_ini = -1095.387 uV, v_off_fin = -1100.223 uV 12:44:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.530 uVs 12:44:31 Integrated Voltage Measurement... 12:44:40 Voltage Offset Correction: v_off_ini = -1091.578 uV, v_off_fin = -1068.163 uV 12:44:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.313 uVs 12:44:40 Integrated Voltage Measurement... 12:44:49 Voltage Offset Correction: v_off_ini = -1104.356 uV, v_off_fin = -1099.521 uV 12:44:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.775 uVs 12:44:49 Integrated Voltage Measurement... 12:44:58 Voltage Offset Correction: v_off_ini = -1088.373 uV, v_off_fin = -1064.387 uV 12:44:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.072 uVs 12:45:03 I1Y Average and RMS of Measurements VT = -228.384 +- 5.567 uVs I1Y = -45.677 +- 1.113 uTm 12:45:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:45:10 Integrated Voltage Measurement... 12:45:19 Voltage Offset Correction: v_off_ini = -1086.813 uV, v_off_fin = -1091.439 uV 12:45:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -68.663 uVs 12:45:19 Integrated Voltage Measurement... 12:45:28 Voltage Offset Correction: v_off_ini = -1077.187 uV, v_off_fin = -1055.461 uV 12:45:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 60.415 uVs 12:45:28 Integrated Voltage Measurement... 12:45:37 Voltage Offset Correction: v_off_ini = -1052.466 uV, v_off_fin = -1063.057 uV 12:45:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -63.263 uVs 12:45:37 Integrated Voltage Measurement... 12:45:46 Voltage Offset Correction: v_off_ini = -1056.936 uV, v_off_fin = -1047.407 uV 12:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.450 uVs 12:45:46 Integrated Voltage Measurement... 12:45:55 Voltage Offset Correction: v_off_ini = -1058.380 uV, v_off_fin = -1043.010 uV 12:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.729 uVs 12:45:55 Integrated Voltage Measurement... 12:46:04 Voltage Offset Correction: v_off_ini = -1042.531 uV, v_off_fin = -1033.272 uV 12:46:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 60.392 uVs 12:46:07 I2X Average and RMS of Measurements VT = -61.152 +- 3.093 uVs I2X = 5.626 +- 0.284 uTm^2 12:46:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:46:15 Integrated Voltage Measurement... 12:46:23 Voltage Offset Correction: v_off_ini = -1028.561 uV, v_off_fin = -1035.854 uV 12:46:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.601 uVs 12:46:24 Integrated Voltage Measurement... 12:46:32 Voltage Offset Correction: v_off_ini = -1039.504 uV, v_off_fin = -1025.152 uV 12:46:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.571 uVs 12:46:33 Integrated Voltage Measurement... 12:46:42 Voltage Offset Correction: v_off_ini = -1023.321 uV, v_off_fin = -1021.887 uV 12:46:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.451 uVs 12:46:42 Integrated Voltage Measurement... 12:46:51 Voltage Offset Correction: v_off_ini = -1019.020 uV, v_off_fin = -1026.217 uV 12:46:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.185 uVs 12:46:51 Integrated Voltage Measurement... 12:47:00 Voltage Offset Correction: v_off_ini = -1014.621 uV, v_off_fin = -1005.198 uV 12:47:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.330 uVs 12:47:00 Integrated Voltage Measurement... 12:47:09 Voltage Offset Correction: v_off_ini = -1004.461 uV, v_off_fin = -990.995 uV 12:47:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.765 uVs 12:47:11 I2Y Average and RMS of Measurements VT = -199.150 +- 5.752 uVs I2Y = -18.322 +- 0.529 uTm^2 12:47:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:47:26 Integrated Voltage Measurement... 12:47:35 Voltage Offset Correction: v_off_ini = -977.659 uV, v_off_fin = -991.931 uV 12:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.226 uVs 12:47:35 Integrated Voltage Measurement... 12:47:44 Voltage Offset Correction: v_off_ini = -968.021 uV, v_off_fin = -980.547 uV 12:47:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.779 uVs 12:47:44 Integrated Voltage Measurement... 12:47:53 Voltage Offset Correction: v_off_ini = -978.035 uV, v_off_fin = -989.780 uV 12:47:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.450 uVs 12:47:53 Integrated Voltage Measurement... 12:48:02 Voltage Offset Correction: v_off_ini = -1000.244 uV, v_off_fin = -986.177 uV 12:48:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.612 uVs 12:48:02 Integrated Voltage Measurement... 12:48:11 Voltage Offset Correction: v_off_ini = -990.167 uV, v_off_fin = -981.401 uV 12:48:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.931 uVs 12:48:11 Integrated Voltage Measurement... 12:48:20 Voltage Offset Correction: v_off_ini = -986.150 uV, v_off_fin = -987.870 uV 12:48:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 78.286 uVs 12:48:24 I1X Average and RMS of Measurements VT = -78.547 +- 9.080 uVs I1X = 15.710 +- 1.816 uTm 12:48:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:48:31 Integrated Voltage Measurement... 12:48:40 Voltage Offset Correction: v_off_ini = -962.441 uV, v_off_fin = -978.305 uV 12:48:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.726 uVs 12:48:40 Integrated Voltage Measurement... 12:48:49 Voltage Offset Correction: v_off_ini = -983.830 uV, v_off_fin = -970.797 uV 12:48:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.116 uVs 12:48:49 Integrated Voltage Measurement... 12:48:58 Voltage Offset Correction: v_off_ini = -977.999 uV, v_off_fin = -990.775 uV 12:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.154 uVs 12:48:58 Integrated Voltage Measurement... 12:49:07 Voltage Offset Correction: v_off_ini = -988.874 uV, v_off_fin = -969.810 uV 12:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.149 uVs 12:49:07 Integrated Voltage Measurement... 12:49:16 Voltage Offset Correction: v_off_ini = -976.174 uV, v_off_fin = -988.498 uV 12:49:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.267 uVs 12:49:16 Integrated Voltage Measurement... 12:49:25 Voltage Offset Correction: v_off_ini = -974.367 uV, v_off_fin = -971.889 uV 12:49:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.081 uVs 12:49:29 I1Y Average and RMS of Measurements VT = -250.749 +- 8.317 uVs I1Y = -50.150 +- 1.663 uTm 12:49:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:49:37 Integrated Voltage Measurement... 12:49:46 Voltage Offset Correction: v_off_ini = -982.883 uV, v_off_fin = -996.060 uV 12:49:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -57.931 uVs 12:49:46 Integrated Voltage Measurement... 12:49:55 Voltage Offset Correction: v_off_ini = -977.227 uV, v_off_fin = -968.283 uV 12:49:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 30.877 uVs 12:49:55 Integrated Voltage Measurement... 12:50:04 Voltage Offset Correction: v_off_ini = -977.030 uV, v_off_fin = -988.188 uV 12:50:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.126 uVs 12:50:04 Integrated Voltage Measurement... 12:50:13 Voltage Offset Correction: v_off_ini = -985.596 uV, v_off_fin = -967.738 uV 12:50:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.785 uVs 12:50:13 Integrated Voltage Measurement... 12:50:22 Voltage Offset Correction: v_off_ini = -958.979 uV, v_off_fin = -965.684 uV 12:50:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -49.364 uVs 12:50:22 Integrated Voltage Measurement... 12:50:31 Voltage Offset Correction: v_off_ini = -961.855 uV, v_off_fin = -956.300 uV 12:50:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 60.038 uVs 12:50:33 I2X Average and RMS of Measurements VT = -52.187 +- 5.617 uVs I2X = 4.801 +- 0.517 uTm^2 12:50:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:50:41 Integrated Voltage Measurement... 12:50:50 Voltage Offset Correction: v_off_ini = -954.052 uV, v_off_fin = -968.540 uV 12:50:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.858 uVs 12:50:50 Integrated Voltage Measurement... 12:50:59 Voltage Offset Correction: v_off_ini = -947.604 uV, v_off_fin = -939.046 uV 12:50:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.746 uVs 12:50:59 Integrated Voltage Measurement... 12:51:08 Voltage Offset Correction: v_off_ini = -944.602 uV, v_off_fin = -939.600 uV 12:51:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.111 uVs 12:51:08 Integrated Voltage Measurement... 12:51:17 Voltage Offset Correction: v_off_ini = -951.511 uV, v_off_fin = -944.716 uV 12:51:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.508 uVs 12:51:17 Integrated Voltage Measurement... 12:51:26 Voltage Offset Correction: v_off_ini = -944.627 uV, v_off_fin = -939.868 uV 12:51:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.821 uVs 12:51:26 Integrated Voltage Measurement... 12:51:35 Voltage Offset Correction: v_off_ini = -923.743 uV, v_off_fin = -922.423 uV 12:51:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.510 uVs 12:51:38 I2Y Average and RMS of Measurements VT = -208.425 +- 4.072 uVs I2Y = -19.175 +- 0.375 uTm^2 12:51:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:51:53 Integrated Voltage Measurement... 12:52:02 Voltage Offset Correction: v_off_ini = -925.776 uV, v_off_fin = -918.244 uV 12:52:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.859 uVs 12:52:02 Integrated Voltage Measurement... 12:52:11 Voltage Offset Correction: v_off_ini = -912.020 uV, v_off_fin = -899.152 uV 12:52:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.483 uVs 12:52:11 Integrated Voltage Measurement... 12:52:20 Voltage Offset Correction: v_off_ini = -901.461 uV, v_off_fin = -905.625 uV 12:52:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.657 uVs 12:52:20 Integrated Voltage Measurement... 12:52:29 Voltage Offset Correction: v_off_ini = -888.575 uV, v_off_fin = -883.610 uV 12:52:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 95.337 uVs 12:52:29 Integrated Voltage Measurement... 12:52:38 Voltage Offset Correction: v_off_ini = -896.807 uV, v_off_fin = -902.987 uV 12:52:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.246 uVs 12:52:38 Integrated Voltage Measurement... 12:52:47 Voltage Offset Correction: v_off_ini = -893.824 uV, v_off_fin = -892.809 uV 12:52:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.434 uVs 12:52:51 I1X Average and RMS of Measurements VT = -78.169 +- 8.416 uVs I1X = 15.634 +- 1.683 uTm 12:52:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:52:58 Integrated Voltage Measurement... 12:53:07 Voltage Offset Correction: v_off_ini = -878.364 uV, v_off_fin = -893.994 uV 12:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.172 uVs 12:53:07 Integrated Voltage Measurement... 12:53:16 Voltage Offset Correction: v_off_ini = -889.465 uV, v_off_fin = -877.703 uV 12:53:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.861 uVs 12:53:16 Integrated Voltage Measurement... 12:53:25 Voltage Offset Correction: v_off_ini = -894.871 uV, v_off_fin = -906.188 uV 12:53:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.436 uVs 12:53:25 Integrated Voltage Measurement... 12:53:34 Voltage Offset Correction: v_off_ini = -902.770 uV, v_off_fin = -873.595 uV 12:53:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.134 uVs 12:53:34 Integrated Voltage Measurement... 12:53:43 Voltage Offset Correction: v_off_ini = -874.914 uV, v_off_fin = -880.635 uV 12:53:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.316 uVs 12:53:43 Integrated Voltage Measurement... 12:53:52 Voltage Offset Correction: v_off_ini = -855.957 uV, v_off_fin = -843.750 uV 12:53:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.705 uVs 12:53:56 I1Y Average and RMS of Measurements VT = -249.937 +- 5.109 uVs I1Y = -49.987 +- 1.022 uTm 12:54:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:54:04 Integrated Voltage Measurement... 12:54:13 Voltage Offset Correction: v_off_ini = -866.011 uV, v_off_fin = -869.769 uV 12:54:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -78.989 uVs 12:54:13 Integrated Voltage Measurement... 12:54:22 Voltage Offset Correction: v_off_ini = -883.273 uV, v_off_fin = -858.922 uV 12:54:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.649 uVs 12:54:22 Integrated Voltage Measurement... 12:54:31 Voltage Offset Correction: v_off_ini = -863.306 uV, v_off_fin = -872.218 uV 12:54:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.569 uVs 12:54:31 Integrated Voltage Measurement... 12:54:40 Voltage Offset Correction: v_off_ini = -860.225 uV, v_off_fin = -846.074 uV 12:54:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.651 uVs 12:54:40 Integrated Voltage Measurement... 12:54:49 Voltage Offset Correction: v_off_ini = -844.944 uV, v_off_fin = -869.712 uV 12:54:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.201 uVs 12:54:49 Integrated Voltage Measurement... 12:54:58 Voltage Offset Correction: v_off_ini = -845.687 uV, v_off_fin = -825.176 uV 12:54:58 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.032 uVs 12:55:00 I2X Average and RMS of Measurements VT = -56.348 +- 6.678 uVs I2X = 5.184 +- 0.614 uTm^2 12:55:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:55:08 Integrated Voltage Measurement... 12:55:17 Voltage Offset Correction: v_off_ini = -863.332 uV, v_off_fin = -849.942 uV 12:55:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.305 uVs 12:55:17 Integrated Voltage Measurement... 12:55:26 Voltage Offset Correction: v_off_ini = -837.950 uV, v_off_fin = -839.095 uV 12:55:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.961 uVs 12:55:26 Integrated Voltage Measurement... 12:55:35 Voltage Offset Correction: v_off_ini = -832.022 uV, v_off_fin = -826.614 uV 12:55:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.213 uVs 12:55:35 Integrated Voltage Measurement... 12:55:44 Voltage Offset Correction: v_off_ini = -840.825 uV, v_off_fin = -847.206 uV 12:55:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.281 uVs 12:55:44 Integrated Voltage Measurement... 12:55:53 Voltage Offset Correction: v_off_ini = -844.621 uV, v_off_fin = -841.486 uV 12:55:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -230.750 uVs 12:55:53 Integrated Voltage Measurement... 12:56:02 Voltage Offset Correction: v_off_ini = -830.659 uV, v_off_fin = -819.534 uV 12:56:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.466 uVs 12:56:05 I2Y Average and RMS of Measurements VT = -230.996 +- 2.744 uVs I2Y = -21.252 +- 0.253 uTm^2 12:56:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:56:20 Integrated Voltage Measurement... 12:56:29 Voltage Offset Correction: v_off_ini = -820.685 uV, v_off_fin = -830.706 uV 12:56:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.106 uVs 12:56:29 Integrated Voltage Measurement... 12:56:38 Voltage Offset Correction: v_off_ini = -819.394 uV, v_off_fin = -823.260 uV 12:56:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.575 uVs 12:56:38 Integrated Voltage Measurement... 12:56:47 Voltage Offset Correction: v_off_ini = -831.630 uV, v_off_fin = -840.269 uV 12:56:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.265 uVs 12:56:47 Integrated Voltage Measurement... 12:56:56 Voltage Offset Correction: v_off_ini = -837.669 uV, v_off_fin = -812.176 uV 12:56:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.548 uVs 12:56:56 Integrated Voltage Measurement... 12:57:05 Voltage Offset Correction: v_off_ini = -811.834 uV, v_off_fin = -828.141 uV 12:57:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.909 uVs 12:57:05 Integrated Voltage Measurement... 12:57:14 Voltage Offset Correction: v_off_ini = -835.617 uV, v_off_fin = -826.955 uV 12:57:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.530 uVs 12:57:18 I1X Average and RMS of Measurements VT = -65.822 +- 4.675 uVs I1X = 13.165 +- 0.935 uTm 12:57:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:57:25 Integrated Voltage Measurement... 12:57:34 Voltage Offset Correction: v_off_ini = -822.097 uV, v_off_fin = -824.099 uV 12:57:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.317 uVs 12:57:34 Integrated Voltage Measurement... 12:57:43 Voltage Offset Correction: v_off_ini = -793.948 uV, v_off_fin = -785.958 uV 12:57:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.058 uVs 12:57:43 Integrated Voltage Measurement... 12:57:52 Voltage Offset Correction: v_off_ini = -790.226 uV, v_off_fin = -808.136 uV 12:57:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.894 uVs 12:57:52 Integrated Voltage Measurement... 12:58:01 Voltage Offset Correction: v_off_ini = -785.677 uV, v_off_fin = -772.925 uV 12:58:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.034 uVs 12:58:01 Integrated Voltage Measurement... 12:58:10 Voltage Offset Correction: v_off_ini = -781.533 uV, v_off_fin = -797.834 uV 12:58:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.317 uVs 12:58:10 Integrated Voltage Measurement... 12:58:19 Voltage Offset Correction: v_off_ini = -777.496 uV, v_off_fin = -771.505 uV 12:58:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.281 uVs 12:58:23 I1Y Average and RMS of Measurements VT = -249.817 +- 4.836 uVs I1Y = -49.963 +- 0.967 uTm 12:58:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:58:31 Integrated Voltage Measurement... 12:58:40 Voltage Offset Correction: v_off_ini = -781.676 uV, v_off_fin = -791.448 uV 12:58:40 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -30.716 uVs 12:58:40 Integrated Voltage Measurement... 12:58:49 Voltage Offset Correction: v_off_ini = -776.104 uV, v_off_fin = -778.784 uV 12:58:49 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 43.131 uVs 12:58:49 Integrated Voltage Measurement... 12:58:58 Voltage Offset Correction: v_off_ini = -780.091 uV, v_off_fin = -790.136 uV 12:58:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.102 uVs 12:58:58 Integrated Voltage Measurement... 12:59:07 Voltage Offset Correction: v_off_ini = -763.639 uV, v_off_fin = -753.546 uV 12:59:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 33.523 uVs 12:59:07 Integrated Voltage Measurement... 12:59:16 Voltage Offset Correction: v_off_ini = -763.984 uV, v_off_fin = -770.734 uV 12:59:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -38.274 uVs 12:59:16 Integrated Voltage Measurement... 12:59:25 Voltage Offset Correction: v_off_ini = -756.482 uV, v_off_fin = -754.944 uV 12:59:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.486 uVs 12:59:27 I2X Average and RMS of Measurements VT = -42.372 +- 3.897 uVs I2X = 3.898 +- 0.359 uTm^2 12:59:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:59:35 Integrated Voltage Measurement... 12:59:44 Voltage Offset Correction: v_off_ini = -752.641 uV, v_off_fin = -751.877 uV 12:59:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.761 uVs 12:59:44 Integrated Voltage Measurement... 12:59:53 Voltage Offset Correction: v_off_ini = -758.921 uV, v_off_fin = -761.778 uV 12:59:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.894 uVs 12:59:53 Integrated Voltage Measurement... 13:00:02 Voltage Offset Correction: v_off_ini = -768.211 uV, v_off_fin = -764.700 uV 13:00:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.644 uVs 13:00:02 Integrated Voltage Measurement... 13:00:11 Voltage Offset Correction: v_off_ini = -760.256 uV, v_off_fin = -766.073 uV 13:00:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.754 uVs 13:00:11 Integrated Voltage Measurement... 13:00:20 Voltage Offset Correction: v_off_ini = -781.045 uV, v_off_fin = -768.885 uV 13:00:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.914 uVs 13:00:20 Integrated Voltage Measurement... 13:00:29 Voltage Offset Correction: v_off_ini = -772.457 uV, v_off_fin = -764.729 uV 13:00:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.738 uVs 13:00:32 I2Y Average and RMS of Measurements VT = -228.951 +- 2.253 uVs I2Y = -21.063 +- 0.207 uTm^2 13:00:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:00:47 Integrated Voltage Measurement... 13:00:56 Voltage Offset Correction: v_off_ini = -763.517 uV, v_off_fin = -763.689 uV 13:00:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.888 uVs 13:00:56 Integrated Voltage Measurement... 13:01:05 Voltage Offset Correction: v_off_ini = -737.631 uV, v_off_fin = -717.741 uV 13:01:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.414 uVs 13:01:05 Integrated Voltage Measurement... 13:01:14 Voltage Offset Correction: v_off_ini = -724.864 uV, v_off_fin = -751.413 uV 13:01:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.607 uVs 13:01:14 Integrated Voltage Measurement... 13:01:23 Voltage Offset Correction: v_off_ini = -736.082 uV, v_off_fin = -742.542 uV 13:01:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.989 uVs 13:01:23 Integrated Voltage Measurement... 13:01:32 Voltage Offset Correction: v_off_ini = -740.257 uV, v_off_fin = -735.170 uV 13:01:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.005 uVs 13:01:32 Integrated Voltage Measurement... 13:01:41 Voltage Offset Correction: v_off_ini = -738.902 uV, v_off_fin = -719.956 uV 13:01:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.570 uVs 13:01:45 I1X Average and RMS of Measurements VT = -60.412 +- 7.378 uVs I1X = 12.083 +- 1.476 uTm 13:01:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:01:52 Integrated Voltage Measurement... 13:02:01 Voltage Offset Correction: v_off_ini = -728.798 uV, v_off_fin = -726.174 uV 13:02:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -276.673 uVs 13:02:01 Integrated Voltage Measurement... 13:02:10 Voltage Offset Correction: v_off_ini = -715.850 uV, v_off_fin = -691.788 uV 13:02:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.497 uVs 13:02:10 Integrated Voltage Measurement... 13:02:19 Voltage Offset Correction: v_off_ini = -713.993 uV, v_off_fin = -714.989 uV 13:02:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.387 uVs 13:02:19 Integrated Voltage Measurement... 13:02:28 Voltage Offset Correction: v_off_ini = -704.684 uV, v_off_fin = -703.613 uV 13:02:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.432 uVs 13:02:28 Integrated Voltage Measurement... 13:02:37 Voltage Offset Correction: v_off_ini = -697.351 uV, v_off_fin = -710.012 uV 13:02:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.526 uVs 13:02:37 Integrated Voltage Measurement... 13:02:46 Voltage Offset Correction: v_off_ini = -701.091 uV, v_off_fin = -697.878 uV 13:02:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.119 uVs 13:02:50 I1Y Average and RMS of Measurements VT = -269.439 +- 3.747 uVs I1Y = -53.888 +- 0.749 uTm 13:02:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:02:58 Integrated Voltage Measurement... 13:03:07 Voltage Offset Correction: v_off_ini = -710.567 uV, v_off_fin = -726.325 uV 13:03:07 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -37.337 uVs 13:03:07 Integrated Voltage Measurement... 13:03:16 Voltage Offset Correction: v_off_ini = -703.999 uV, v_off_fin = -693.579 uV 13:03:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.826 uVs 13:03:16 Integrated Voltage Measurement... 13:03:25 Voltage Offset Correction: v_off_ini = -703.254 uV, v_off_fin = -702.445 uV 13:03:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.237 uVs 13:03:25 Integrated Voltage Measurement... 13:03:34 Voltage Offset Correction: v_off_ini = -691.995 uV, v_off_fin = -695.128 uV 13:03:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.798 uVs 13:03:34 Integrated Voltage Measurement... 13:03:43 Voltage Offset Correction: v_off_ini = -691.859 uV, v_off_fin = -686.457 uV 13:03:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.920 uVs 13:03:43 Integrated Voltage Measurement... 13:03:52 Voltage Offset Correction: v_off_ini = -689.973 uV, v_off_fin = -675.063 uV 13:03:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.409 uVs 13:03:55 I2X Average and RMS of Measurements VT = -53.088 +- 6.137 uVs I2X = 4.884 +- 0.565 uTm^2 13:04:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:04:02 Integrated Voltage Measurement... 13:04:11 Voltage Offset Correction: v_off_ini = -669.031 uV, v_off_fin = -683.730 uV 13:04:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -254.665 uVs 13:04:11 Integrated Voltage Measurement... 13:04:20 Voltage Offset Correction: v_off_ini = -685.194 uV, v_off_fin = -686.371 uV 13:04:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.785 uVs 13:04:21 Integrated Voltage Measurement... 13:04:29 Voltage Offset Correction: v_off_ini = -679.088 uV, v_off_fin = -691.636 uV 13:04:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.462 uVs 13:04:30 Integrated Voltage Measurement... 13:04:39 Voltage Offset Correction: v_off_ini = -695.425 uV, v_off_fin = -674.576 uV 13:04:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.595 uVs 13:04:39 Integrated Voltage Measurement... 13:04:48 Voltage Offset Correction: v_off_ini = -676.158 uV, v_off_fin = -707.376 uV 13:04:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.739 uVs 13:04:48 Integrated Voltage Measurement... 13:04:57 Voltage Offset Correction: v_off_ini = -692.253 uV, v_off_fin = -703.969 uV 13:04:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.942 uVs 13:04:59 I2Y Average and RMS of Measurements VT = -241.198 +- 5.628 uVs I2Y = -22.191 +- 0.518 uTm^2 13:05:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:05:14 Integrated Voltage Measurement... 13:05:23 Voltage Offset Correction: v_off_ini = -693.093 uV, v_off_fin = -726.010 uV 13:05:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.587 uVs 13:05:23 Integrated Voltage Measurement... 13:05:32 Voltage Offset Correction: v_off_ini = -710.290 uV, v_off_fin = -689.460 uV 13:05:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.034 uVs 13:05:32 Integrated Voltage Measurement... 13:05:41 Voltage Offset Correction: v_off_ini = -695.745 uV, v_off_fin = -697.434 uV 13:05:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.284 uVs 13:05:41 Integrated Voltage Measurement... 13:05:50 Voltage Offset Correction: v_off_ini = -679.083 uV, v_off_fin = -677.656 uV 13:05:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.362 uVs 13:05:50 Integrated Voltage Measurement... 13:05:59 Voltage Offset Correction: v_off_ini = -688.831 uV, v_off_fin = -694.078 uV 13:05:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.016 uVs 13:05:59 Integrated Voltage Measurement... 13:06:08 Voltage Offset Correction: v_off_ini = -676.114 uV, v_off_fin = -671.147 uV 13:06:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.608 uVs 13:06:12 I1X Average and RMS of Measurements VT = -65.149 +- 7.527 uVs I1X = 13.030 +- 1.505 uTm 13:06:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:06:19 Integrated Voltage Measurement... 13:06:28 Voltage Offset Correction: v_off_ini = -667.644 uV, v_off_fin = -669.868 uV 13:06:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.355 uVs 13:06:28 Integrated Voltage Measurement... 13:06:37 Voltage Offset Correction: v_off_ini = -669.375 uV, v_off_fin = -649.115 uV 13:06:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.810 uVs 13:06:37 Integrated Voltage Measurement... 13:06:46 Voltage Offset Correction: v_off_ini = -665.823 uV, v_off_fin = -674.481 uV 13:06:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.766 uVs 13:06:46 Integrated Voltage Measurement... 13:06:55 Voltage Offset Correction: v_off_ini = -659.642 uV, v_off_fin = -642.533 uV 13:06:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.143 uVs 13:06:55 Integrated Voltage Measurement... 13:07:04 Voltage Offset Correction: v_off_ini = -668.120 uV, v_off_fin = -666.966 uV 13:07:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.757 uVs 13:07:04 Integrated Voltage Measurement... 13:07:13 Voltage Offset Correction: v_off_ini = -645.598 uV, v_off_fin = -631.922 uV 13:07:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.310 uVs 13:07:17 I1Y Average and RMS of Measurements VT = -274.524 +- 1.173 uVs I1Y = -54.905 +- 0.235 uTm 13:07:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:07:25 Integrated Voltage Measurement... 13:07:34 Voltage Offset Correction: v_off_ini = -620.100 uV, v_off_fin = -636.089 uV 13:07:34 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -39.346 uVs 13:07:34 Integrated Voltage Measurement... 13:07:43 Voltage Offset Correction: v_off_ini = -629.819 uV, v_off_fin = -621.849 uV 13:07:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 19.036 uVs 13:07:43 Integrated Voltage Measurement... 13:07:52 Voltage Offset Correction: v_off_ini = -629.471 uV, v_off_fin = -628.458 uV 13:07:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.857 uVs 13:07:52 Integrated Voltage Measurement... 13:08:01 Voltage Offset Correction: v_off_ini = -633.495 uV, v_off_fin = -613.514 uV 13:08:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.922 uVs 13:08:01 Integrated Voltage Measurement... 13:08:10 Voltage Offset Correction: v_off_ini = -635.060 uV, v_off_fin = -641.501 uV 13:08:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.135 uVs 13:08:10 Integrated Voltage Measurement... 13:08:19 Voltage Offset Correction: v_off_ini = -633.423 uV, v_off_fin = -637.076 uV 13:08:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.686 uVs 13:08:22 I2X Average and RMS of Measurements VT = -34.997 +- 5.007 uVs I2X = 3.220 +- 0.461 uTm^2 13:08:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:08:30 Integrated Voltage Measurement... 13:08:39 Voltage Offset Correction: v_off_ini = -614.496 uV, v_off_fin = -616.183 uV 13:08:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.908 uVs 13:08:39 Integrated Voltage Measurement... 13:08:48 Voltage Offset Correction: v_off_ini = -604.565 uV, v_off_fin = -608.095 uV 13:08:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.537 uVs 13:08:48 Integrated Voltage Measurement... 13:08:57 Voltage Offset Correction: v_off_ini = -607.132 uV, v_off_fin = -613.223 uV 13:08:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.628 uVs 13:08:57 Integrated Voltage Measurement... 13:09:06 Voltage Offset Correction: v_off_ini = -614.845 uV, v_off_fin = -608.745 uV 13:09:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.429 uVs 13:09:06 Integrated Voltage Measurement... 13:09:15 Voltage Offset Correction: v_off_ini = -601.104 uV, v_off_fin = -607.727 uV 13:09:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.009 uVs 13:09:15 Integrated Voltage Measurement... 13:09:24 Voltage Offset Correction: v_off_ini = -606.379 uV, v_off_fin = -608.465 uV 13:09:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.944 uVs 13:09:26 I2Y Average and RMS of Measurements VT = -251.742 +- 3.780 uVs I2Y = -23.160 +- 0.348 uTm^2 13:09:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:09:41 Integrated Voltage Measurement... 13:09:50 Voltage Offset Correction: v_off_ini = -598.518 uV, v_off_fin = -585.126 uV 13:09:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.053 uVs 13:09:50 Integrated Voltage Measurement... 13:09:59 Voltage Offset Correction: v_off_ini = -606.724 uV, v_off_fin = -576.644 uV 13:09:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.439 uVs 13:09:59 Integrated Voltage Measurement... 13:10:08 Voltage Offset Correction: v_off_ini = -584.301 uV, v_off_fin = -578.192 uV 13:10:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.892 uVs 13:10:08 Integrated Voltage Measurement... 13:10:17 Voltage Offset Correction: v_off_ini = -584.736 uV, v_off_fin = -587.041 uV 13:10:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.363 uVs 13:10:17 Integrated Voltage Measurement... 13:10:26 Voltage Offset Correction: v_off_ini = -582.936 uV, v_off_fin = -575.339 uV 13:10:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.568 uVs 13:10:26 Integrated Voltage Measurement... 13:10:35 Voltage Offset Correction: v_off_ini = -578.489 uV, v_off_fin = -570.656 uV 13:10:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.860 uVs 13:10:40 I1X Average and RMS of Measurements VT = -65.362 +- 3.499 uVs I1X = 13.073 +- 0.699 uTm 13:10:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:10:46 Integrated Voltage Measurement... 13:10:55 Voltage Offset Correction: v_off_ini = -565.850 uV, v_off_fin = -580.163 uV 13:10:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -278.997 uVs 13:10:55 Integrated Voltage Measurement... 13:11:04 Voltage Offset Correction: v_off_ini = -570.028 uV, v_off_fin = -544.278 uV 13:11:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.513 uVs 13:11:04 Integrated Voltage Measurement... 13:11:13 Voltage Offset Correction: v_off_ini = -554.284 uV, v_off_fin = -565.430 uV 13:11:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -300.777 uVs 13:11:13 Integrated Voltage Measurement... 13:11:22 Voltage Offset Correction: v_off_ini = -544.459 uV, v_off_fin = -537.776 uV 13:11:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.928 uVs 13:11:22 Integrated Voltage Measurement... 13:11:31 Voltage Offset Correction: v_off_ini = -545.254 uV, v_off_fin = -572.472 uV 13:11:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.300 uVs 13:11:31 Integrated Voltage Measurement... 13:11:40 Voltage Offset Correction: v_off_ini = -563.801 uV, v_off_fin = -545.304 uV 13:11:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 276.477 uVs 13:11:45 I1Y Average and RMS of Measurements VT = -276.499 +- 4.671 uVs I1Y = -55.301 +- 0.933 uTm 13:11:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:52 Integrated Voltage Measurement... 13:12:01 Voltage Offset Correction: v_off_ini = -541.940 uV, v_off_fin = -545.836 uV 13:12:01 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -38.916 uVs 13:12:01 Integrated Voltage Measurement... 13:12:10 Voltage Offset Correction: v_off_ini = -542.838 uV, v_off_fin = -515.447 uV 13:12:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.437 uVs 13:12:10 Integrated Voltage Measurement... 13:12:19 Voltage Offset Correction: v_off_ini = -538.193 uV, v_off_fin = -526.240 uV 13:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.970 uVs 13:12:20 Integrated Voltage Measurement... 13:12:28 Voltage Offset Correction: v_off_ini = -522.304 uV, v_off_fin = -509.166 uV 13:12:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.755 uVs 13:12:29 Integrated Voltage Measurement... 13:12:38 Voltage Offset Correction: v_off_ini = -522.527 uV, v_off_fin = -530.469 uV 13:12:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.780 uVs 13:12:38 Integrated Voltage Measurement... 13:12:47 Voltage Offset Correction: v_off_ini = -511.910 uV, v_off_fin = -520.779 uV 13:12:47 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 22.791 uVs 13:12:49 I2X Average and RMS of Measurements VT = -31.108 +- 3.413 uVs I2X = 2.862 +- 0.314 uTm^2 13:12:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:57 Integrated Voltage Measurement... 13:13:06 Voltage Offset Correction: v_off_ini = -508.899 uV, v_off_fin = -516.767 uV 13:13:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.903 uVs 13:13:06 Integrated Voltage Measurement... 13:13:15 Voltage Offset Correction: v_off_ini = -511.885 uV, v_off_fin = -504.836 uV 13:13:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.083 uVs 13:13:15 Integrated Voltage Measurement... 13:13:24 Voltage Offset Correction: v_off_ini = -504.316 uV, v_off_fin = -513.462 uV 13:13:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.036 uVs 13:13:24 Integrated Voltage Measurement... 13:13:33 Voltage Offset Correction: v_off_ini = -511.005 uV, v_off_fin = -513.879 uV 13:13:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.103 uVs 13:13:33 Integrated Voltage Measurement... 13:13:42 Voltage Offset Correction: v_off_ini = -502.300 uV, v_off_fin = -499.403 uV 13:13:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.821 uVs 13:13:42 Integrated Voltage Measurement... 13:13:51 Voltage Offset Correction: v_off_ini = -488.016 uV, v_off_fin = -495.075 uV 13:13:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.656 uVs 13:13:53 I2Y Average and RMS of Measurements VT = -255.434 +- 12.271 uVs I2Y = -23.500 +- 1.129 uTm^2 13:14:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:14:08 Integrated Voltage Measurement... 13:14:17 Voltage Offset Correction: v_off_ini = -457.524 uV, v_off_fin = -456.037 uV 13:14:17 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -67.925 uVs 13:14:17 Integrated Voltage Measurement... 13:14:26 Voltage Offset Correction: v_off_ini = -436.023 uV, v_off_fin = -440.964 uV 13:14:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.508 uVs 13:14:26 Integrated Voltage Measurement... 13:14:35 Voltage Offset Correction: v_off_ini = -470.318 uV, v_off_fin = -453.017 uV 13:14:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.444 uVs 13:14:35 Integrated Voltage Measurement... 13:14:44 Voltage Offset Correction: v_off_ini = -468.793 uV, v_off_fin = -451.439 uV 13:14:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.005 uVs 13:14:45 Integrated Voltage Measurement... 13:14:53 Voltage Offset Correction: v_off_ini = -460.272 uV, v_off_fin = -457.645 uV 13:14:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.646 uVs 13:14:54 Integrated Voltage Measurement... 13:15:02 Voltage Offset Correction: v_off_ini = -462.817 uV, v_off_fin = -464.646 uV 13:15:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.129 uVs 13:15:07 I1X Average and RMS of Measurements VT = -54.443 +- 6.310 uVs I1X = 10.889 +- 1.262 uTm 13:15:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:14 Integrated Voltage Measurement... 13:15:22 Voltage Offset Correction: v_off_ini = -449.440 uV, v_off_fin = -441.786 uV 13:15:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -270.770 uVs 13:15:23 Integrated Voltage Measurement... 13:15:31 Voltage Offset Correction: v_off_ini = -446.005 uV, v_off_fin = -426.746 uV 13:15:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.881 uVs 13:15:32 Integrated Voltage Measurement... 13:15:41 Voltage Offset Correction: v_off_ini = -452.346 uV, v_off_fin = -467.943 uV 13:15:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.011 uVs 13:15:41 Integrated Voltage Measurement... 13:15:50 Voltage Offset Correction: v_off_ini = -446.134 uV, v_off_fin = -431.585 uV 13:15:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 276.325 uVs 13:15:50 Integrated Voltage Measurement... 13:15:59 Voltage Offset Correction: v_off_ini = -426.194 uV, v_off_fin = -440.649 uV 13:15:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.051 uVs 13:15:59 Integrated Voltage Measurement... 13:16:08 Voltage Offset Correction: v_off_ini = -437.287 uV, v_off_fin = -411.539 uV 13:16:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.774 uVs 13:16:12 I1Y Average and RMS of Measurements VT = -277.302 +- 1.770 uVs I1Y = -55.461 +- 0.354 uTm 13:16:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:16:20 Integrated Voltage Measurement... 13:16:29 Voltage Offset Correction: v_off_ini = -437.335 uV, v_off_fin = -438.734 uV 13:16:29 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -39.162 uVs 13:16:29 Integrated Voltage Measurement... 13:16:38 Voltage Offset Correction: v_off_ini = -437.400 uV, v_off_fin = -430.064 uV 13:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.558 uVs 13:16:38 Integrated Voltage Measurement... 13:16:47 Voltage Offset Correction: v_off_ini = -443.952 uV, v_off_fin = -436.436 uV 13:16:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.157 uVs 13:16:47 Integrated Voltage Measurement... 13:16:56 Voltage Offset Correction: v_off_ini = -430.790 uV, v_off_fin = -411.737 uV 13:16:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.973 uVs 13:16:56 Integrated Voltage Measurement... 13:17:05 Voltage Offset Correction: v_off_ini = -429.177 uV, v_off_fin = -449.674 uV 13:17:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.821 uVs 13:17:05 Integrated Voltage Measurement... 13:17:14 Voltage Offset Correction: v_off_ini = -437.226 uV, v_off_fin = -420.758 uV 13:17:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.016 uVs 13:17:16 I2X Average and RMS of Measurements VT = -30.948 +- 3.886 uVs I2X = 2.847 +- 0.357 uTm^2 13:17:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:17:24 Integrated Voltage Measurement... 13:17:33 Voltage Offset Correction: v_off_ini = -424.814 uV, v_off_fin = -420.016 uV 13:17:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.113 uVs 13:17:33 Integrated Voltage Measurement... 13:17:42 Voltage Offset Correction: v_off_ini = -433.076 uV, v_off_fin = -436.000 uV 13:17:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.910 uVs 13:17:42 Integrated Voltage Measurement... 13:17:51 Voltage Offset Correction: v_off_ini = -411.700 uV, v_off_fin = -423.027 uV 13:17:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.331 uVs 13:17:51 Integrated Voltage Measurement... 13:18:00 Voltage Offset Correction: v_off_ini = -424.012 uV, v_off_fin = -420.191 uV 13:18:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.095 uVs 13:18:00 Integrated Voltage Measurement... 13:18:09 Voltage Offset Correction: v_off_ini = -432.008 uV, v_off_fin = -436.172 uV 13:18:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.204 uVs 13:18:09 Integrated Voltage Measurement... 13:18:18 Voltage Offset Correction: v_off_ini = -433.014 uV, v_off_fin = -437.958 uV 13:18:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.872 uVs 13:18:21 I2Y Average and RMS of Measurements VT = -254.921 +- 2.290 uVs I2Y = -23.453 +- 0.211 uTm^2 13:18:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:18:37 Integrated Voltage Measurement... 13:18:46 Voltage Offset Correction: v_off_ini = -416.553 uV, v_off_fin = -432.552 uV 13:18:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -47.116 uVs 13:18:46 Integrated Voltage Measurement... 13:18:55 Voltage Offset Correction: v_off_ini = -427.843 uV, v_off_fin = -429.793 uV 13:18:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 32.392 uVs 13:18:55 Integrated Voltage Measurement... 13:19:04 Voltage Offset Correction: v_off_ini = -420.010 uV, v_off_fin = -415.130 uV 13:19:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.406 uVs 13:19:04 Integrated Voltage Measurement... 13:19:13 Voltage Offset Correction: v_off_ini = -413.875 uV, v_off_fin = -396.230 uV 13:19:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.460 uVs 13:19:13 Integrated Voltage Measurement... 13:19:22 Voltage Offset Correction: v_off_ini = -417.230 uV, v_off_fin = -423.203 uV 13:19:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.102 uVs 13:19:22 Integrated Voltage Measurement... 13:19:31 Voltage Offset Correction: v_off_ini = -433.005 uV, v_off_fin = -429.027 uV 13:19:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.578 uVs 13:19:35 I1X Average and RMS of Measurements VT = -50.509 +- 7.614 uVs I1X = 10.102 +- 1.522 uTm 13:19:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:19:42 Integrated Voltage Measurement... 13:19:51 Voltage Offset Correction: v_off_ini = -426.709 uV, v_off_fin = -433.681 uV 13:19:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -288.978 uVs 13:19:51 Integrated Voltage Measurement... 13:20:00 Voltage Offset Correction: v_off_ini = -421.538 uV, v_off_fin = -394.695 uV 13:20:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.006 uVs 13:20:00 Integrated Voltage Measurement... 13:20:09 Voltage Offset Correction: v_off_ini = -413.471 uV, v_off_fin = -415.364 uV 13:20:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.471 uVs 13:20:09 Integrated Voltage Measurement... 13:20:18 Voltage Offset Correction: v_off_ini = -417.118 uV, v_off_fin = -409.250 uV 13:20:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.518 uVs 13:20:18 Integrated Voltage Measurement... 13:20:27 Voltage Offset Correction: v_off_ini = -416.035 uV, v_off_fin = -432.971 uV 13:20:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -278.144 uVs 13:20:27 Integrated Voltage Measurement... 13:20:36 Voltage Offset Correction: v_off_ini = -422.230 uV, v_off_fin = -411.730 uV 13:20:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.368 uVs 13:20:40 I1Y Average and RMS of Measurements VT = -282.914 +- 3.626 uVs I1Y = -56.584 +- 0.727 uTm 13:20:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:20:48 Integrated Voltage Measurement... 13:20:57 Voltage Offset Correction: v_off_ini = -439.281 uV, v_off_fin = -425.296 uV 13:20:57 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -29.255 uVs 13:20:57 Integrated Voltage Measurement... 13:21:06 Voltage Offset Correction: v_off_ini = -422.038 uV, v_off_fin = -414.960 uV 13:21:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 48.094 uVs 13:21:06 Integrated Voltage Measurement... 13:21:15 Voltage Offset Correction: v_off_ini = -420.130 uV, v_off_fin = -424.974 uV 13:21:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.700 uVs 13:21:15 Integrated Voltage Measurement... 13:21:24 Voltage Offset Correction: v_off_ini = -421.509 uV, v_off_fin = -412.370 uV 13:21:24 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 51.190 uVs 13:21:24 Integrated Voltage Measurement... 13:21:33 Voltage Offset Correction: v_off_ini = -412.705 uV, v_off_fin = -426.911 uV 13:21:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.937 uVs 13:21:33 Integrated Voltage Measurement... 13:21:42 Voltage Offset Correction: v_off_ini = -404.220 uV, v_off_fin = -391.187 uV 13:21:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.046 uVs 13:21:44 I2X Average and RMS of Measurements VT = -38.204 +- 3.671 uVs I2X = 3.515 +- 0.338 uTm^2 13:21:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:21:52 Integrated Voltage Measurement... 13:22:01 Voltage Offset Correction: v_off_ini = -397.714 uV, v_off_fin = -407.151 uV 13:22:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.172 uVs 13:22:01 Integrated Voltage Measurement... 13:22:10 Voltage Offset Correction: v_off_ini = -391.379 uV, v_off_fin = -380.902 uV 13:22:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.563 uVs 13:22:10 Integrated Voltage Measurement... 13:22:19 Voltage Offset Correction: v_off_ini = -382.775 uV, v_off_fin = -385.597 uV 13:22:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.316 uVs 13:22:19 Integrated Voltage Measurement... 13:22:28 Voltage Offset Correction: v_off_ini = -378.013 uV, v_off_fin = -386.461 uV 13:22:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.485 uVs 13:22:28 Integrated Voltage Measurement... 13:22:37 Voltage Offset Correction: v_off_ini = -377.769 uV, v_off_fin = -388.381 uV 13:22:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.577 uVs 13:22:37 Integrated Voltage Measurement... 13:22:46 Voltage Offset Correction: v_off_ini = -398.705 uV, v_off_fin = -392.399 uV 13:22:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.995 uVs 13:22:49 I2Y Average and RMS of Measurements VT = -253.185 +- 6.965 uVs I2Y = -23.293 +- 0.641 uTm^2 13:23:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:23:05 Integrated Voltage Measurement... 13:23:14 Voltage Offset Correction: v_off_ini = -360.104 uV, v_off_fin = -366.813 uV 13:23:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.266 uVs 13:23:14 Integrated Voltage Measurement... 13:23:23 Voltage Offset Correction: v_off_ini = -367.836 uV, v_off_fin = -348.036 uV 13:23:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.922 uVs 13:23:23 Integrated Voltage Measurement... 13:23:32 Voltage Offset Correction: v_off_ini = -347.061 uV, v_off_fin = -357.107 uV 13:23:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.545 uVs 13:23:32 Integrated Voltage Measurement... 13:23:41 Voltage Offset Correction: v_off_ini = -347.458 uV, v_off_fin = -343.734 uV 13:23:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.714 uVs 13:23:41 Integrated Voltage Measurement... 13:23:50 Voltage Offset Correction: v_off_ini = -377.800 uV, v_off_fin = -360.501 uV 13:23:50 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -51.075 uVs 13:23:50 Integrated Voltage Measurement... 13:23:59 Voltage Offset Correction: v_off_ini = -378.876 uV, v_off_fin = -374.783 uV 13:23:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.117 uVs 13:24:03 I1X Average and RMS of Measurements VT = -54.107 +- 6.178 uVs I1X = 10.822 +- 1.236 uTm 13:24:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:24:10 Integrated Voltage Measurement... 13:24:19 Voltage Offset Correction: v_off_ini = -376.976 uV, v_off_fin = -375.314 uV 13:24:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -273.896 uVs 13:24:19 Integrated Voltage Measurement... 13:24:28 Voltage Offset Correction: v_off_ini = -363.118 uV, v_off_fin = -345.243 uV 13:24:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.153 uVs 13:24:28 Integrated Voltage Measurement... 13:24:37 Voltage Offset Correction: v_off_ini = -369.720 uV, v_off_fin = -390.911 uV 13:24:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -298.196 uVs 13:24:37 Integrated Voltage Measurement... 13:24:46 Voltage Offset Correction: v_off_ini = -350.796 uV, v_off_fin = -329.467 uV 13:24:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.704 uVs 13:24:46 Integrated Voltage Measurement... 13:24:55 Voltage Offset Correction: v_off_ini = -336.778 uV, v_off_fin = -332.835 uV 13:24:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.754 uVs 13:24:55 Integrated Voltage Measurement... 13:25:04 Voltage Offset Correction: v_off_ini = -322.095 uV, v_off_fin = -314.396 uV 13:25:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.601 uVs 13:25:08 I1Y Average and RMS of Measurements VT = -281.051 +- 4.210 uVs I1Y = -56.211 +- 0.842 uTm 13:25:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:25:16 Integrated Voltage Measurement... 13:25:25 Voltage Offset Correction: v_off_ini = -360.095 uV, v_off_fin = -356.612 uV 13:25:25 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -35.815 uVs 13:25:25 Integrated Voltage Measurement... 13:25:34 Voltage Offset Correction: v_off_ini = -364.955 uV, v_off_fin = -344.169 uV 13:25:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.153 uVs 13:25:34 Integrated Voltage Measurement... 13:25:43 Voltage Offset Correction: v_off_ini = -371.357 uV, v_off_fin = -373.453 uV 13:25:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.722 uVs 13:25:43 Integrated Voltage Measurement... 13:25:52 Voltage Offset Correction: v_off_ini = -341.162 uV, v_off_fin = -312.873 uV 13:25:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 45.782 uVs 13:25:52 Integrated Voltage Measurement... 13:26:01 Voltage Offset Correction: v_off_ini = -334.100 uV, v_off_fin = -342.962 uV 13:26:01 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -37.074 uVs 13:26:01 Integrated Voltage Measurement... 13:26:10 Voltage Offset Correction: v_off_ini = -338.456 uV, v_off_fin = -328.590 uV 13:26:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.157 uVs 13:26:13 I2X Average and RMS of Measurements VT = -31.784 +- 5.203 uVs I2X = 2.924 +- 0.478 uTm^2 13:26:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:26:20 Integrated Voltage Measurement... 13:26:29 Voltage Offset Correction: v_off_ini = -317.131 uV, v_off_fin = -324.007 uV 13:26:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.401 uVs 13:26:29 Integrated Voltage Measurement... 13:26:38 Voltage Offset Correction: v_off_ini = -332.925 uV, v_off_fin = -327.353 uV 13:26:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.670 uVs 13:26:38 Integrated Voltage Measurement... 13:26:47 Voltage Offset Correction: v_off_ini = -325.175 uV, v_off_fin = -324.911 uV 13:26:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.533 uVs 13:26:47 Integrated Voltage Measurement... 13:26:56 Voltage Offset Correction: v_off_ini = -308.223 uV, v_off_fin = -310.877 uV 13:26:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.076 uVs 13:26:56 Integrated Voltage Measurement... 13:27:05 Voltage Offset Correction: v_off_ini = -326.532 uV, v_off_fin = -313.248 uV 13:27:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.022 uVs 13:27:05 Integrated Voltage Measurement... 13:27:14 Voltage Offset Correction: v_off_ini = -316.910 uV, v_off_fin = -324.689 uV 13:27:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.326 uVs 13:27:17 I2Y Average and RMS of Measurements VT = -253.338 +- 1.276 uVs I2Y = -23.307 +- 0.117 uTm^2 13:27:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:27:35 Integrated Voltage Measurement... 13:27:44 Voltage Offset Correction: v_off_ini = -299.877 uV, v_off_fin = -319.097 uV 13:27:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -50.539 uVs 13:27:44 Integrated Voltage Measurement... 13:27:53 Voltage Offset Correction: v_off_ini = -308.993 uV, v_off_fin = -309.092 uV 13:27:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.144 uVs 13:27:53 Integrated Voltage Measurement... 13:28:02 Voltage Offset Correction: v_off_ini = -313.138 uV, v_off_fin = -319.309 uV 13:28:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.393 uVs 13:28:02 Integrated Voltage Measurement... 13:28:11 Voltage Offset Correction: v_off_ini = -304.605 uV, v_off_fin = -309.131 uV 13:28:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.542 uVs 13:28:11 Integrated Voltage Measurement... 13:28:20 Voltage Offset Correction: v_off_ini = -308.902 uV, v_off_fin = -305.658 uV 13:28:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.130 uVs 13:28:20 Integrated Voltage Measurement... 13:28:29 Voltage Offset Correction: v_off_ini = -318.434 uV, v_off_fin = -299.037 uV 13:28:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.527 uVs 13:28:34 I1X Average and RMS of Measurements VT = -54.712 +- 9.318 uVs I1X = 10.943 +- 1.863 uTm 13:28:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:28:40 Integrated Voltage Measurement... 13:28:49 Voltage Offset Correction: v_off_ini = -317.093 uV, v_off_fin = -320.547 uV 13:28:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -278.761 uVs 13:28:49 Integrated Voltage Measurement... 13:28:58 Voltage Offset Correction: v_off_ini = -297.750 uV, v_off_fin = -287.286 uV 13:28:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.844 uVs 13:28:58 Integrated Voltage Measurement... 13:29:07 Voltage Offset Correction: v_off_ini = -300.688 uV, v_off_fin = -322.560 uV 13:29:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.718 uVs 13:29:07 Integrated Voltage Measurement... 13:29:16 Voltage Offset Correction: v_off_ini = -305.573 uV, v_off_fin = -289.643 uV 13:29:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 267.619 uVs 13:29:16 Integrated Voltage Measurement... 13:29:25 Voltage Offset Correction: v_off_ini = -294.596 uV, v_off_fin = -321.171 uV 13:29:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -285.257 uVs 13:29:25 Integrated Voltage Measurement... 13:29:34 Voltage Offset Correction: v_off_ini = -302.030 uV, v_off_fin = -289.967 uV 13:29:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.458 uVs 13:29:39 I1Y Average and RMS of Measurements VT = -271.943 +- 2.986 uVs I1Y = -54.387 +- 0.597 uTm 13:29:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:29:46 Integrated Voltage Measurement... 13:29:55 Voltage Offset Correction: v_off_ini = -315.993 uV, v_off_fin = -324.164 uV 13:29:55 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -36.340 uVs 13:29:55 Integrated Voltage Measurement... 13:30:04 Voltage Offset Correction: v_off_ini = -297.169 uV, v_off_fin = -299.158 uV 13:30:04 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 16.216 uVs 13:30:04 Integrated Voltage Measurement... 13:30:13 Voltage Offset Correction: v_off_ini = -315.248 uV, v_off_fin = -325.787 uV 13:30:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -40.445 uVs 13:30:13 Integrated Voltage Measurement... 13:30:22 Voltage Offset Correction: v_off_ini = -311.925 uV, v_off_fin = -309.909 uV 13:30:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.903 uVs 13:30:22 Integrated Voltage Measurement... 13:30:31 Voltage Offset Correction: v_off_ini = -317.299 uV, v_off_fin = -329.925 uV 13:30:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.808 uVs 13:30:31 Integrated Voltage Measurement... 13:30:40 Voltage Offset Correction: v_off_ini = -323.270 uV, v_off_fin = -307.573 uV 13:30:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 45.839 uVs 13:30:43 I2X Average and RMS of Measurements VT = -38.092 +- 9.184 uVs I2X = 3.504 +- 0.845 uTm^2 13:30:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:30:51 Integrated Voltage Measurement... 13:31:00 Voltage Offset Correction: v_off_ini = -296.828 uV, v_off_fin = -305.813 uV 13:31:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.106 uVs 13:31:00 Integrated Voltage Measurement... 13:31:09 Voltage Offset Correction: v_off_ini = -301.976 uV, v_off_fin = -307.570 uV 13:31:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.035 uVs 13:31:09 Integrated Voltage Measurement... 13:31:18 Voltage Offset Correction: v_off_ini = -317.589 uV, v_off_fin = -311.159 uV 13:31:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.500 uVs 13:31:18 Integrated Voltage Measurement... 13:31:27 Voltage Offset Correction: v_off_ini = -315.142 uV, v_off_fin = -310.617 uV 13:31:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.866 uVs 13:31:27 Integrated Voltage Measurement... 13:31:36 Voltage Offset Correction: v_off_ini = -327.332 uV, v_off_fin = -315.398 uV 13:31:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.629 uVs 13:31:36 Integrated Voltage Measurement... 13:31:45 Voltage Offset Correction: v_off_ini = -299.455 uV, v_off_fin = -302.831 uV 13:31:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.971 uVs 13:31:47 I2Y Average and RMS of Measurements VT = -257.518 +- 5.884 uVs I2Y = -23.692 +- 0.541 uTm^2 13:32:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:32:05 Integrated Voltage Measurement... 13:32:14 Voltage Offset Correction: v_off_ini = -313.362 uV, v_off_fin = -323.784 uV 13:32:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.814 uVs 13:32:15 Integrated Voltage Measurement... 13:32:23 Voltage Offset Correction: v_off_ini = -310.972 uV, v_off_fin = -306.015 uV 13:32:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.670 uVs 13:32:24 Integrated Voltage Measurement... 13:32:32 Voltage Offset Correction: v_off_ini = -313.961 uV, v_off_fin = -309.294 uV 13:32:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -62.210 uVs 13:32:33 Integrated Voltage Measurement... 13:32:41 Voltage Offset Correction: v_off_ini = -314.948 uV, v_off_fin = -292.386 uV 13:32:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 64.142 uVs 13:32:42 Integrated Voltage Measurement... 13:32:50 Voltage Offset Correction: v_off_ini = -289.301 uV, v_off_fin = -295.004 uV 13:32:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.675 uVs 13:32:51 Integrated Voltage Measurement... 13:32:59 Voltage Offset Correction: v_off_ini = -285.276 uV, v_off_fin = -285.041 uV 13:33:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 52.512 uVs 13:33:04 I1X Average and RMS of Measurements VT = -56.837 +- 5.510 uVs I1X = 11.369 +- 1.103 uTm 13:33:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:33:11 Integrated Voltage Measurement... 13:33:19 Voltage Offset Correction: v_off_ini = -284.059 uV, v_off_fin = -288.411 uV 13:33:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -276.114 uVs 13:33:20 Integrated Voltage Measurement... 13:33:28 Voltage Offset Correction: v_off_ini = -280.681 uV, v_off_fin = -268.496 uV 13:33:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.987 uVs 13:33:29 Integrated Voltage Measurement... 13:33:37 Voltage Offset Correction: v_off_ini = -278.076 uV, v_off_fin = -281.119 uV 13:33:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.515 uVs 13:33:38 Integrated Voltage Measurement... 13:33:46 Voltage Offset Correction: v_off_ini = -275.851 uV, v_off_fin = -271.807 uV 13:33:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.529 uVs 13:33:47 Integrated Voltage Measurement... 13:33:56 Voltage Offset Correction: v_off_ini = -291.776 uV, v_off_fin = -305.912 uV 13:33:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -270.695 uVs 13:33:56 Integrated Voltage Measurement... 13:34:05 Voltage Offset Correction: v_off_ini = -286.554 uV, v_off_fin = -268.510 uV 13:34:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.431 uVs 13:34:09 I1Y Average and RMS of Measurements VT = -265.878 +- 5.949 uVs I1Y = -53.176 +- 1.190 uTm 13:34:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:16 Integrated Voltage Measurement... 13:34:25 Voltage Offset Correction: v_off_ini = -315.280 uV, v_off_fin = -311.863 uV 13:34:25 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -28.098 uVs 13:34:26 Integrated Voltage Measurement... 13:34:35 Voltage Offset Correction: v_off_ini = -300.476 uV, v_off_fin = -308.454 uV 13:34:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.692 uVs 13:34:35 Integrated Voltage Measurement... 13:34:44 Voltage Offset Correction: v_off_ini = -312.684 uV, v_off_fin = -314.678 uV 13:34:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.921 uVs 13:34:44 Integrated Voltage Measurement... 13:34:53 Voltage Offset Correction: v_off_ini = -312.192 uV, v_off_fin = -292.239 uV 13:34:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.155 uVs 13:34:53 Integrated Voltage Measurement... 13:35:02 Voltage Offset Correction: v_off_ini = -287.034 uV, v_off_fin = -306.669 uV 13:35:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -46.562 uVs 13:35:02 Integrated Voltage Measurement... 13:35:11 Voltage Offset Correction: v_off_ini = -275.108 uV, v_off_fin = -287.107 uV 13:35:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.280 uVs 13:35:13 I2X Average and RMS of Measurements VT = -40.951 +- 4.662 uVs I2X = 3.767 +- 0.429 uTm^2 13:35:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:21 Integrated Voltage Measurement... 13:35:30 Voltage Offset Correction: v_off_ini = -302.351 uV, v_off_fin = -300.906 uV 13:35:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.174 uVs 13:35:30 Integrated Voltage Measurement... 13:35:39 Voltage Offset Correction: v_off_ini = -303.129 uV, v_off_fin = -300.501 uV 13:35:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.268 uVs 13:35:39 Integrated Voltage Measurement... 13:35:48 Voltage Offset Correction: v_off_ini = -301.977 uV, v_off_fin = -296.414 uV 13:35:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.842 uVs 13:35:48 Integrated Voltage Measurement... 13:35:57 Voltage Offset Correction: v_off_ini = -287.974 uV, v_off_fin = -289.014 uV 13:35:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.987 uVs 13:35:57 Integrated Voltage Measurement... 13:36:06 Voltage Offset Correction: v_off_ini = -281.375 uV, v_off_fin = -284.233 uV 13:36:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.057 uVs 13:36:06 Integrated Voltage Measurement... 13:36:15 Voltage Offset Correction: v_off_ini = -276.691 uV, v_off_fin = -303.658 uV 13:36:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.776 uVs 13:36:17 I2Y Average and RMS of Measurements VT = -248.851 +- 1.835 uVs I2Y = -22.894 +- 0.169 uTm^2 13:36:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:36 Integrated Voltage Measurement... 13:36:45 Voltage Offset Correction: v_off_ini = -259.275 uV, v_off_fin = -277.435 uV 13:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.395 uVs 13:36:45 Integrated Voltage Measurement... 13:36:54 Voltage Offset Correction: v_off_ini = -278.446 uV, v_off_fin = -272.923 uV 13:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.199 uVs 13:36:54 Integrated Voltage Measurement... 13:37:03 Voltage Offset Correction: v_off_ini = -283.711 uV, v_off_fin = -284.000 uV 13:37:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.006 uVs 13:37:03 Integrated Voltage Measurement... 13:37:12 Voltage Offset Correction: v_off_ini = -290.250 uV, v_off_fin = -277.014 uV 13:37:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.322 uVs 13:37:12 Integrated Voltage Measurement... 13:37:21 Voltage Offset Correction: v_off_ini = -272.434 uV, v_off_fin = -280.189 uV 13:37:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.910 uVs 13:37:21 Integrated Voltage Measurement... 13:37:30 Voltage Offset Correction: v_off_ini = -273.379 uV, v_off_fin = -275.315 uV 13:37:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.431 uVs 13:37:34 I1X Average and RMS of Measurements VT = -62.544 +- 10.322 uVs I1X = 12.509 +- 2.064 uTm 13:37:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:37:41 Integrated Voltage Measurement... 13:37:50 Voltage Offset Correction: v_off_ini = -273.698 uV, v_off_fin = -278.724 uV 13:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -253.768 uVs 13:37:50 Integrated Voltage Measurement... 13:37:59 Voltage Offset Correction: v_off_ini = -267.053 uV, v_off_fin = -252.069 uV 13:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 251.960 uVs 13:37:59 Integrated Voltage Measurement... 13:38:08 Voltage Offset Correction: v_off_ini = -263.178 uV, v_off_fin = -273.259 uV 13:38:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -260.212 uVs 13:38:08 Integrated Voltage Measurement... 13:38:17 Voltage Offset Correction: v_off_ini = -254.207 uV, v_off_fin = -228.513 uV 13:38:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.490 uVs 13:38:17 Integrated Voltage Measurement... 13:38:26 Voltage Offset Correction: v_off_ini = -260.187 uV, v_off_fin = -282.278 uV 13:38:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.407 uVs 13:38:26 Integrated Voltage Measurement... 13:38:35 Voltage Offset Correction: v_off_ini = -281.181 uV, v_off_fin = -263.803 uV 13:38:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.262 uVs 13:38:39 I1Y Average and RMS of Measurements VT = -257.516 +- 3.314 uVs I1Y = -51.502 +- 0.662 uTm 13:38:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:38:47 Integrated Voltage Measurement... 13:38:56 Voltage Offset Correction: v_off_ini = -259.939 uV, v_off_fin = -280.360 uV 13:38:56 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -72.796 uVs 13:38:56 Integrated Voltage Measurement... 13:39:05 Voltage Offset Correction: v_off_ini = -262.817 uV, v_off_fin = -243.537 uV 13:39:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 38.184 uVs 13:39:05 Integrated Voltage Measurement... 13:39:14 Voltage Offset Correction: v_off_ini = -251.753 uV, v_off_fin = -264.045 uV 13:39:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.278 uVs 13:39:14 Integrated Voltage Measurement... 13:39:23 Voltage Offset Correction: v_off_ini = -242.449 uV, v_off_fin = -241.985 uV 13:39:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 41.775 uVs 13:39:23 Integrated Voltage Measurement... 13:39:32 Voltage Offset Correction: v_off_ini = -250.558 uV, v_off_fin = -269.475 uV 13:39:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.916 uVs 13:39:32 Integrated Voltage Measurement... 13:39:41 Voltage Offset Correction: v_off_ini = -252.142 uV, v_off_fin = -232.996 uV 13:39:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 45.423 uVs 13:39:43 I2X Average and RMS of Measurements VT = -44.229 +- 9.537 uVs I2X = 4.069 +- 0.877 uTm^2 13:39:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:39:51 Integrated Voltage Measurement... 13:40:00 Voltage Offset Correction: v_off_ini = -232.731 uV, v_off_fin = -231.021 uV 13:40:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.585 uVs 13:40:00 Integrated Voltage Measurement... 13:40:09 Voltage Offset Correction: v_off_ini = -230.030 uV, v_off_fin = -226.173 uV 13:40:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.497 uVs 13:40:09 Integrated Voltage Measurement... 13:40:18 Voltage Offset Correction: v_off_ini = -228.155 uV, v_off_fin = -231.146 uV 13:40:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.521 uVs 13:40:18 Integrated Voltage Measurement... 13:40:27 Voltage Offset Correction: v_off_ini = -227.664 uV, v_off_fin = -223.292 uV 13:40:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.624 uVs 13:40:27 Integrated Voltage Measurement... 13:40:36 Voltage Offset Correction: v_off_ini = -242.115 uV, v_off_fin = -233.416 uV 13:40:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.552 uVs 13:40:36 Integrated Voltage Measurement... 13:40:45 Voltage Offset Correction: v_off_ini = -211.557 uV, v_off_fin = -210.973 uV 13:40:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.943 uVs 13:40:48 I2Y Average and RMS of Measurements VT = -237.453 +- 1.172 uVs I2Y = -21.846 +- 0.108 uTm^2 13:41:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:41:06 Integrated Voltage Measurement... 13:41:15 Voltage Offset Correction: v_off_ini = -194.217 uV, v_off_fin = -195.862 uV 13:41:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.729 uVs 13:41:15 Integrated Voltage Measurement... 13:41:24 Voltage Offset Correction: v_off_ini = -211.728 uV, v_off_fin = -215.091 uV 13:41:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.510 uVs 13:41:24 Integrated Voltage Measurement... 13:41:33 Voltage Offset Correction: v_off_ini = -215.861 uV, v_off_fin = -213.058 uV 13:41:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.581 uVs 13:41:33 Integrated Voltage Measurement... 13:41:42 Voltage Offset Correction: v_off_ini = -185.467 uV, v_off_fin = -188.460 uV 13:41:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.748 uVs 13:41:42 Integrated Voltage Measurement... 13:41:51 Voltage Offset Correction: v_off_ini = -188.969 uV, v_off_fin = -192.426 uV 13:41:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.061 uVs 13:41:51 Integrated Voltage Measurement... 13:42:00 Voltage Offset Correction: v_off_ini = -188.514 uV, v_off_fin = -193.887 uV 13:42:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.723 uVs 13:42:04 I1X Average and RMS of Measurements VT = -60.892 +- 8.736 uVs I1X = 12.178 +- 1.747 uTm 13:42:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:42:11 Integrated Voltage Measurement... 13:42:20 Voltage Offset Correction: v_off_ini = -182.278 uV, v_off_fin = -197.388 uV 13:42:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.287 uVs 13:42:20 Integrated Voltage Measurement... 13:42:29 Voltage Offset Correction: v_off_ini = -178.771 uV, v_off_fin = -169.376 uV 13:42:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.909 uVs 13:42:29 Integrated Voltage Measurement... 13:42:38 Voltage Offset Correction: v_off_ini = -184.122 uV, v_off_fin = -186.559 uV 13:42:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.067 uVs 13:42:38 Integrated Voltage Measurement... 13:42:47 Voltage Offset Correction: v_off_ini = -179.836 uV, v_off_fin = -173.762 uV 13:42:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.750 uVs 13:42:47 Integrated Voltage Measurement... 13:42:56 Voltage Offset Correction: v_off_ini = -192.062 uV, v_off_fin = -208.189 uV 13:42:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.048 uVs 13:42:56 Integrated Voltage Measurement... 13:43:05 Voltage Offset Correction: v_off_ini = -181.784 uV, v_off_fin = -173.283 uV 13:43:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.612 uVs 13:43:09 I1Y Average and RMS of Measurements VT = -241.945 +- 5.831 uVs I1Y = -48.389 +- 1.166 uTm 13:43:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:43:17 Integrated Voltage Measurement... 13:43:26 Voltage Offset Correction: v_off_ini = -174.328 uV, v_off_fin = -188.519 uV 13:43:26 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -31.822 uVs 13:43:26 Integrated Voltage Measurement... 13:43:35 Voltage Offset Correction: v_off_ini = -177.555 uV, v_off_fin = -168.539 uV 13:43:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.351 uVs 13:43:35 Integrated Voltage Measurement... 13:43:44 Voltage Offset Correction: v_off_ini = -167.966 uV, v_off_fin = -177.633 uV 13:43:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -56.224 uVs 13:43:44 Integrated Voltage Measurement... 13:43:53 Voltage Offset Correction: v_off_ini = -171.163 uV, v_off_fin = -159.648 uV 13:43:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 48.194 uVs 13:43:53 Integrated Voltage Measurement... 13:44:02 Voltage Offset Correction: v_off_ini = -188.733 uV, v_off_fin = -183.049 uV 13:44:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.909 uVs 13:44:02 Integrated Voltage Measurement... 13:44:11 Voltage Offset Correction: v_off_ini = -181.277 uV, v_off_fin = -159.949 uV 13:44:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 53.158 uVs 13:44:14 I2X Average and RMS of Measurements VT = -47.443 +- 8.437 uVs I2X = 4.365 +- 0.777 uTm^2 13:44:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:44:21 Integrated Voltage Measurement... 13:44:30 Voltage Offset Correction: v_off_ini = -202.368 uV, v_off_fin = -197.539 uV 13:44:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.272 uVs 13:44:30 Integrated Voltage Measurement... 13:44:39 Voltage Offset Correction: v_off_ini = -186.931 uV, v_off_fin = -185.038 uV 13:44:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.536 uVs 13:44:39 Integrated Voltage Measurement... 13:44:48 Voltage Offset Correction: v_off_ini = -187.776 uV, v_off_fin = -189.971 uV 13:44:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.587 uVs 13:44:48 Integrated Voltage Measurement... 13:44:57 Voltage Offset Correction: v_off_ini = -192.810 uV, v_off_fin = -183.707 uV 13:44:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 232.669 uVs 13:44:57 Integrated Voltage Measurement... 13:45:06 Voltage Offset Correction: v_off_ini = -182.605 uV, v_off_fin = -194.085 uV 13:45:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.217 uVs 13:45:06 Integrated Voltage Measurement... 13:45:15 Voltage Offset Correction: v_off_ini = -186.838 uV, v_off_fin = -193.812 uV 13:45:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.703 uVs 13:45:18 I2Y Average and RMS of Measurements VT = -234.164 +- 3.363 uVs I2Y = -21.543 +- 0.309 uTm^2 13:45:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:45:36 Integrated Voltage Measurement... 13:45:45 Voltage Offset Correction: v_off_ini = -178.622 uV, v_off_fin = -191.253 uV 13:45:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.438 uVs 13:45:45 Integrated Voltage Measurement... 13:45:54 Voltage Offset Correction: v_off_ini = -188.802 uV, v_off_fin = -176.628 uV 13:45:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.741 uVs 13:45:54 Integrated Voltage Measurement... 13:46:03 Voltage Offset Correction: v_off_ini = -183.564 uV, v_off_fin = -187.693 uV 13:46:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.756 uVs 13:46:03 Integrated Voltage Measurement... 13:46:12 Voltage Offset Correction: v_off_ini = -187.055 uV, v_off_fin = -193.477 uV 13:46:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 65.473 uVs 13:46:12 Integrated Voltage Measurement... 13:46:21 Voltage Offset Correction: v_off_ini = -201.253 uV, v_off_fin = -210.258 uV 13:46:21 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.555 uVs 13:46:21 Integrated Voltage Measurement... 13:46:30 Voltage Offset Correction: v_off_ini = -190.913 uV, v_off_fin = -203.495 uV 13:46:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 47.951 uVs 13:46:35 I1X Average and RMS of Measurements VT = -66.486 +- 16.189 uVs I1X = 13.298 +- 3.238 uTm 13:46:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:46:41 Integrated Voltage Measurement... 13:46:50 Voltage Offset Correction: v_off_ini = -197.319 uV, v_off_fin = -212.590 uV 13:46:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.626 uVs 13:46:50 Integrated Voltage Measurement... 13:46:59 Voltage Offset Correction: v_off_ini = -181.928 uV, v_off_fin = -184.670 uV 13:46:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.992 uVs 13:46:59 Integrated Voltage Measurement... 13:47:08 Voltage Offset Correction: v_off_ini = -199.679 uV, v_off_fin = -214.236 uV 13:47:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.547 uVs 13:47:08 Integrated Voltage Measurement... 13:47:17 Voltage Offset Correction: v_off_ini = -198.623 uV, v_off_fin = -188.448 uV 13:47:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.039 uVs 13:47:17 Integrated Voltage Measurement... 13:47:26 Voltage Offset Correction: v_off_ini = -206.703 uV, v_off_fin = -217.477 uV 13:47:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.265 uVs 13:47:26 Integrated Voltage Measurement... 13:47:35 Voltage Offset Correction: v_off_ini = -205.024 uV, v_off_fin = -169.185 uV 13:47:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.273 uVs 13:47:40 I1Y Average and RMS of Measurements VT = -240.957 +- 1.943 uVs I1Y = -48.191 +- 0.389 uTm 13:47:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:47:47 Integrated Voltage Measurement... 13:47:56 Voltage Offset Correction: v_off_ini = -206.081 uV, v_off_fin = -198.750 uV 13:47:56 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -56.399 uVs 13:47:56 Integrated Voltage Measurement... 13:48:05 Voltage Offset Correction: v_off_ini = -181.311 uV, v_off_fin = -183.702 uV 13:48:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.631 uVs 13:48:05 Integrated Voltage Measurement... 13:48:14 Voltage Offset Correction: v_off_ini = -193.160 uV, v_off_fin = -197.529 uV 13:48:14 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -42.335 uVs 13:48:14 Integrated Voltage Measurement... 13:48:23 Voltage Offset Correction: v_off_ini = -193.161 uV, v_off_fin = -181.026 uV 13:48:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.860 uVs 13:48:23 Integrated Voltage Measurement... 13:48:32 Voltage Offset Correction: v_off_ini = -196.127 uV, v_off_fin = -194.324 uV 13:48:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.139 uVs 13:48:32 Integrated Voltage Measurement... 13:48:41 Voltage Offset Correction: v_off_ini = -193.494 uV, v_off_fin = -176.378 uV 13:48:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.449 uVs 13:48:44 I2X Average and RMS of Measurements VT = -56.136 +- 6.871 uVs I2X = 5.165 +- 0.632 uTm^2 13:48:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:48:52 Integrated Voltage Measurement... 13:49:01 Voltage Offset Correction: v_off_ini = -175.094 uV, v_off_fin = -191.762 uV 13:49:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.056 uVs 13:49:01 Integrated Voltage Measurement... 13:49:10 Voltage Offset Correction: v_off_ini = -187.204 uV, v_off_fin = -192.755 uV 13:49:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.134 uVs 13:49:10 Integrated Voltage Measurement... 13:49:19 Voltage Offset Correction: v_off_ini = -186.726 uV, v_off_fin = -184.413 uV 13:49:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.409 uVs 13:49:19 Integrated Voltage Measurement... 13:49:28 Voltage Offset Correction: v_off_ini = -179.011 uV, v_off_fin = -175.771 uV 13:49:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.152 uVs 13:49:28 Integrated Voltage Measurement... 13:49:37 Voltage Offset Correction: v_off_ini = -175.034 uV, v_off_fin = -169.160 uV 13:49:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.044 uVs 13:49:37 Integrated Voltage Measurement... 13:49:46 Voltage Offset Correction: v_off_ini = -160.197 uV, v_off_fin = -165.934 uV 13:49:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.029 uVs 13:49:48 I2Y Average and RMS of Measurements VT = -223.637 +- 4.676 uVs I2Y = -20.575 +- 0.430 uTm^2 13:50:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:50:07 Integrated Voltage Measurement... 13:50:15 Voltage Offset Correction: v_off_ini = -167.391 uV, v_off_fin = -172.406 uV 13:50:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.643 uVs 13:50:16 Integrated Voltage Measurement... 13:50:24 Voltage Offset Correction: v_off_ini = -163.399 uV, v_off_fin = -173.497 uV 13:50:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.355 uVs 13:50:25 Integrated Voltage Measurement... 13:50:34 Voltage Offset Correction: v_off_ini = -172.616 uV, v_off_fin = -169.172 uV 13:50:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -82.545 uVs 13:50:34 Integrated Voltage Measurement... 13:50:43 Voltage Offset Correction: v_off_ini = -170.179 uV, v_off_fin = -168.008 uV 13:50:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.946 uVs 13:50:43 Integrated Voltage Measurement... 13:50:52 Voltage Offset Correction: v_off_ini = -171.509 uV, v_off_fin = -164.281 uV 13:50:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.232 uVs 13:50:52 Integrated Voltage Measurement... 13:51:01 Voltage Offset Correction: v_off_ini = -179.204 uV, v_off_fin = -175.520 uV 13:51:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.486 uVs 13:51:05 I1X Average and RMS of Measurements VT = -71.701 +- 1.187 uVs I1X = 14.341 +- 0.238 uTm 13:51:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:51:12 Integrated Voltage Measurement... 13:51:21 Voltage Offset Correction: v_off_ini = -176.232 uV, v_off_fin = -176.424 uV 13:51:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.902 uVs 13:51:21 Integrated Voltage Measurement... 13:51:30 Voltage Offset Correction: v_off_ini = -174.083 uV, v_off_fin = -157.625 uV 13:51:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.531 uVs 13:51:30 Integrated Voltage Measurement... 13:51:39 Voltage Offset Correction: v_off_ini = -172.468 uV, v_off_fin = -179.782 uV 13:51:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.912 uVs 13:51:39 Integrated Voltage Measurement... 13:51:48 Voltage Offset Correction: v_off_ini = -143.030 uV, v_off_fin = -132.466 uV 13:51:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.983 uVs 13:51:48 Integrated Voltage Measurement... 13:51:57 Voltage Offset Correction: v_off_ini = -128.321 uV, v_off_fin = -143.575 uV 13:51:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.341 uVs 13:51:57 Integrated Voltage Measurement... 13:52:06 Voltage Offset Correction: v_off_ini = -146.918 uV, v_off_fin = -131.141 uV 13:52:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.509 uVs 13:52:10 I1Y Average and RMS of Measurements VT = -237.197 +- 3.420 uVs I1Y = -47.439 +- 0.684 uTm 13:52:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:52:18 Integrated Voltage Measurement... 13:52:27 Voltage Offset Correction: v_off_ini = -140.969 uV, v_off_fin = -148.113 uV 13:52:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -69.428 uVs 13:52:27 Integrated Voltage Measurement... 13:52:36 Voltage Offset Correction: v_off_ini = -147.843 uV, v_off_fin = -132.121 uV 13:52:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.141 uVs 13:52:36 Integrated Voltage Measurement... 13:52:45 Voltage Offset Correction: v_off_ini = -136.570 uV, v_off_fin = -155.070 uV 13:52:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.252 uVs 13:52:45 Integrated Voltage Measurement... 13:52:54 Voltage Offset Correction: v_off_ini = -135.670 uV, v_off_fin = -104.370 uV 13:52:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 68.621 uVs 13:52:54 Integrated Voltage Measurement... 13:53:03 Voltage Offset Correction: v_off_ini = -131.921 uV, v_off_fin = -124.408 uV 13:53:03 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -37.282 uVs 13:53:03 Integrated Voltage Measurement... 13:53:12 Voltage Offset Correction: v_off_ini = -119.321 uV, v_off_fin = -126.507 uV 13:53:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 65.731 uVs 13:53:14 I2X Average and RMS of Measurements VT = -61.242 +- 8.858 uVs I2X = 5.634 +- 0.815 uTm^2 13:53:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:53:22 Integrated Voltage Measurement... 13:53:31 Voltage Offset Correction: v_off_ini = -99.915 uV, v_off_fin = -97.223 uV 13:53:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.841 uVs 13:53:31 Integrated Voltage Measurement... 13:53:40 Voltage Offset Correction: v_off_ini = -98.278 uV, v_off_fin = -106.173 uV 13:53:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.668 uVs 13:53:40 Integrated Voltage Measurement... 13:53:49 Voltage Offset Correction: v_off_ini = -108.528 uV, v_off_fin = -116.392 uV 13:53:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.788 uVs 13:53:49 Integrated Voltage Measurement... 13:53:58 Voltage Offset Correction: v_off_ini = -104.825 uV, v_off_fin = -106.957 uV 13:53:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.105 uVs 13:53:58 Integrated Voltage Measurement... 13:54:07 Voltage Offset Correction: v_off_ini = -102.250 uV, v_off_fin = -123.043 uV 13:54:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.261 uVs 13:54:07 Integrated Voltage Measurement... 13:54:16 Voltage Offset Correction: v_off_ini = -126.489 uV, v_off_fin = -114.703 uV 13:54:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.795 uVs 13:54:18 I2Y Average and RMS of Measurements VT = -215.243 +- 14.264 uVs I2Y = -19.802 +- 1.312 uTm^2 13:54:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm