SLAC Magnetic Measurements Date: 08-20-2025 Time: 13:57:00 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16343 Dataset Number: 1 Run Purpose: Final Results Run Type: Good Field Region Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 13:57:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:10 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:57:11 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:57:13 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:57:14 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 13:57:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:57:55 Integrated Voltage Measurement... 13:58:04 Voltage Offset Correction: v_off_ini = -115.858 uV, v_off_fin = -105.498 uV 13:58:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -102.633 uVs 13:58:04 Integrated Voltage Measurement... 13:58:13 Voltage Offset Correction: v_off_ini = -126.267 uV, v_off_fin = -113.256 uV 13:58:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.949 uVs 13:58:13 Integrated Voltage Measurement... 13:58:22 Voltage Offset Correction: v_off_ini = -112.586 uV, v_off_fin = -137.764 uV 13:58:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.969 uVs 13:58:22 Integrated Voltage Measurement... 13:58:31 Voltage Offset Correction: v_off_ini = -127.619 uV, v_off_fin = -113.531 uV 13:58:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.919 uVs 13:58:31 Integrated Voltage Measurement... 13:58:40 Voltage Offset Correction: v_off_ini = -127.283 uV, v_off_fin = -134.789 uV 13:58:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.790 uVs 13:58:40 Integrated Voltage Measurement... 13:58:49 Voltage Offset Correction: v_off_ini = -134.759 uV, v_off_fin = -128.854 uV 13:58:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.116 uVs 13:58:54 I1X Average and RMS of Measurements VT = -97.563 +- 7.574 uVs I1X = 19.513 +- 1.515 uTm 13:58:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:59:00 Integrated Voltage Measurement... 13:59:09 Voltage Offset Correction: v_off_ini = -107.114 uV, v_off_fin = -113.458 uV 13:59:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -220.696 uVs 13:59:09 Integrated Voltage Measurement... 13:59:18 Voltage Offset Correction: v_off_ini = -115.528 uV, v_off_fin = -95.343 uV 13:59:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.916 uVs 13:59:18 Integrated Voltage Measurement... 13:59:27 Voltage Offset Correction: v_off_ini = -126.700 uV, v_off_fin = -136.990 uV 13:59:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.693 uVs 13:59:27 Integrated Voltage Measurement... 13:59:36 Voltage Offset Correction: v_off_ini = -120.805 uV, v_off_fin = -113.241 uV 13:59:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.973 uVs 13:59:36 Integrated Voltage Measurement... 13:59:45 Voltage Offset Correction: v_off_ini = -122.401 uV, v_off_fin = -130.544 uV 13:59:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.484 uVs 13:59:46 Integrated Voltage Measurement... 13:59:54 Voltage Offset Correction: v_off_ini = -117.025 uV, v_off_fin = -120.281 uV 13:59:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.714 uVs 13:59:59 I1Y Average and RMS of Measurements VT = -207.079 +- 5.805 uVs I1Y = -41.417 +- 1.162 uTm 14:00:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:00:06 Integrated Voltage Measurement... 14:00:15 Voltage Offset Correction: v_off_ini = -118.930 uV, v_off_fin = -138.688 uV 14:00:15 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -58.632 uVs 14:00:15 Integrated Voltage Measurement... 14:00:24 Voltage Offset Correction: v_off_ini = -129.352 uV, v_off_fin = -115.093 uV 14:00:24 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 58.914 uVs 14:00:25 Integrated Voltage Measurement... 14:00:33 Voltage Offset Correction: v_off_ini = -108.427 uV, v_off_fin = -124.073 uV 14:00:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -81.964 uVs 14:00:34 Integrated Voltage Measurement... 14:00:43 Voltage Offset Correction: v_off_ini = -129.478 uV, v_off_fin = -116.290 uV 14:00:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 62.122 uVs 14:00:43 Integrated Voltage Measurement... 14:00:52 Voltage Offset Correction: v_off_ini = -131.860 uV, v_off_fin = -131.601 uV 14:00:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.752 uVs 14:00:52 Integrated Voltage Measurement... 14:01:01 Voltage Offset Correction: v_off_ini = -125.393 uV, v_off_fin = -108.392 uV 14:01:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.180 uVs 14:01:03 I2X Average and RMS of Measurements VT = -61.927 +- 7.320 uVs I2X = 5.698 +- 0.674 uTm^2 14:01:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:01:11 Integrated Voltage Measurement... 14:01:20 Voltage Offset Correction: v_off_ini = -119.191 uV, v_off_fin = -108.185 uV 14:01:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.421 uVs 14:01:20 Integrated Voltage Measurement... 14:01:29 Voltage Offset Correction: v_off_ini = -97.977 uV, v_off_fin = -107.407 uV 14:01:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.605 uVs 14:01:29 Integrated Voltage Measurement... 14:01:38 Voltage Offset Correction: v_off_ini = -108.328 uV, v_off_fin = -118.271 uV 14:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.451 uVs 14:01:38 Integrated Voltage Measurement... 14:01:47 Voltage Offset Correction: v_off_ini = -121.873 uV, v_off_fin = -119.924 uV 14:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.691 uVs 14:01:47 Integrated Voltage Measurement... 14:01:56 Voltage Offset Correction: v_off_ini = -107.350 uV, v_off_fin = -106.057 uV 14:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.559 uVs 14:01:56 Integrated Voltage Measurement... 14:02:05 Voltage Offset Correction: v_off_ini = -115.826 uV, v_off_fin = -120.664 uV 14:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.860 uVs 14:02:07 I2Y Average and RMS of Measurements VT = -184.431 +- 7.093 uVs I2Y = -16.968 +- 0.653 uTm^2 14:02:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:02:16 Integrated Voltage Measurement... 14:02:25 Voltage Offset Correction: v_off_ini = -102.122 uV, v_off_fin = -116.307 uV 14:02:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.177 uVs 14:02:25 Integrated Voltage Measurement... 14:02:34 Voltage Offset Correction: v_off_ini = -115.033 uV, v_off_fin = -121.452 uV 14:02:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.129 uVs 14:02:34 Integrated Voltage Measurement... 14:02:43 Voltage Offset Correction: v_off_ini = -116.239 uV, v_off_fin = -135.786 uV 14:02:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.769 uVs 14:02:43 Integrated Voltage Measurement... 14:02:52 Voltage Offset Correction: v_off_ini = -132.350 uV, v_off_fin = -115.397 uV 14:02:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.776 uVs 14:02:52 Integrated Voltage Measurement... 14:03:01 Voltage Offset Correction: v_off_ini = -126.697 uV, v_off_fin = -125.278 uV 14:03:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.010 uVs 14:03:01 Integrated Voltage Measurement... 14:03:10 Voltage Offset Correction: v_off_ini = -124.110 uV, v_off_fin = -110.816 uV 14:03:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.210 uVs 14:03:15 I1X Average and RMS of Measurements VT = -99.512 +- 0.458 uVs I1X = 19.903 +- 0.091 uTm 14:03:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:03:21 Integrated Voltage Measurement... 14:03:30 Voltage Offset Correction: v_off_ini = -95.299 uV, v_off_fin = -94.704 uV 14:03:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.704 uVs 14:03:30 Integrated Voltage Measurement... 14:03:39 Voltage Offset Correction: v_off_ini = -72.347 uV, v_off_fin = -71.260 uV 14:03:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.019 uVs 14:03:40 Integrated Voltage Measurement... 14:03:48 Voltage Offset Correction: v_off_ini = -96.611 uV, v_off_fin = -96.295 uV 14:03:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.747 uVs 14:03:49 Integrated Voltage Measurement... 14:03:57 Voltage Offset Correction: v_off_ini = -85.661 uV, v_off_fin = -88.993 uV 14:03:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.704 uVs 14:03:58 Integrated Voltage Measurement... 14:04:07 Voltage Offset Correction: v_off_ini = -90.634 uV, v_off_fin = -87.561 uV 14:04:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.356 uVs 14:04:07 Integrated Voltage Measurement... 14:04:16 Voltage Offset Correction: v_off_ini = -88.209 uV, v_off_fin = -72.091 uV 14:04:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.803 uVs 14:04:20 I1Y Average and RMS of Measurements VT = -190.722 +- 3.131 uVs I1Y = -38.144 +- 0.626 uTm 14:04:25 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:04:28 Integrated Voltage Measurement... 14:04:36 Voltage Offset Correction: v_off_ini = -111.648 uV, v_off_fin = -107.122 uV 14:04:37 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -65.362 uVs 14:04:37 Integrated Voltage Measurement... 14:04:46 Voltage Offset Correction: v_off_ini = -97.686 uV, v_off_fin = -84.855 uV 14:04:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.816 uVs 14:04:46 Integrated Voltage Measurement... 14:04:55 Voltage Offset Correction: v_off_ini = -93.449 uV, v_off_fin = -117.540 uV 14:04:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.889 uVs 14:04:55 Integrated Voltage Measurement... 14:05:04 Voltage Offset Correction: v_off_ini = -114.177 uV, v_off_fin = -108.196 uV 14:05:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.100 uVs 14:05:04 Integrated Voltage Measurement... 14:05:13 Voltage Offset Correction: v_off_ini = -115.733 uV, v_off_fin = -99.765 uV 14:05:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.376 uVs 14:05:13 Integrated Voltage Measurement... 14:05:22 Voltage Offset Correction: v_off_ini = -90.566 uV, v_off_fin = -88.885 uV 14:05:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.255 uVs 14:05:24 I2X Average and RMS of Measurements VT = -68.300 +- 9.988 uVs I2X = 6.283 +- 0.919 uTm^2 14:05:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:05:32 Integrated Voltage Measurement... 14:05:41 Voltage Offset Correction: v_off_ini = -104.300 uV, v_off_fin = -94.401 uV 14:05:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -153.326 uVs 14:05:41 Integrated Voltage Measurement... 14:05:50 Voltage Offset Correction: v_off_ini = -96.958 uV, v_off_fin = -91.439 uV 14:05:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.027 uVs 14:05:50 Integrated Voltage Measurement... 14:05:59 Voltage Offset Correction: v_off_ini = -102.683 uV, v_off_fin = -99.761 uV 14:05:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.327 uVs 14:05:59 Integrated Voltage Measurement... 14:06:08 Voltage Offset Correction: v_off_ini = -96.944 uV, v_off_fin = -98.339 uV 14:06:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 169.841 uVs 14:06:08 Integrated Voltage Measurement... 14:06:17 Voltage Offset Correction: v_off_ini = -116.463 uV, v_off_fin = -106.634 uV 14:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.423 uVs 14:06:17 Integrated Voltage Measurement... 14:06:26 Voltage Offset Correction: v_off_ini = -94.801 uV, v_off_fin = -98.346 uV 14:06:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.997 uVs 14:06:29 I2Y Average and RMS of Measurements VT = -166.990 +- 4.321 uVs I2Y = -15.363 +- 0.397 uTm^2 14:06:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:06:37 Integrated Voltage Measurement... 14:06:46 Voltage Offset Correction: v_off_ini = -100.753 uV, v_off_fin = -103.027 uV 14:06:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.900 uVs 14:06:46 Integrated Voltage Measurement... 14:06:55 Voltage Offset Correction: v_off_ini = -100.038 uV, v_off_fin = -97.050 uV 14:06:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.854 uVs 14:06:55 Integrated Voltage Measurement... 14:07:04 Voltage Offset Correction: v_off_ini = -98.582 uV, v_off_fin = -107.898 uV 14:07:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.963 uVs 14:07:05 Integrated Voltage Measurement... 14:07:13 Voltage Offset Correction: v_off_ini = -102.124 uV, v_off_fin = -92.848 uV 14:07:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 107.441 uVs 14:07:14 Integrated Voltage Measurement... 14:07:23 Voltage Offset Correction: v_off_ini = -101.863 uV, v_off_fin = -107.627 uV 14:07:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -125.215 uVs 14:07:23 Integrated Voltage Measurement... 14:07:32 Voltage Offset Correction: v_off_ini = -97.154 uV, v_off_fin = -90.571 uV 14:07:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.101 uVs 14:07:36 I1X Average and RMS of Measurements VT = -106.079 +- 3.754 uVs I1X = 21.216 +- 0.751 uTm 14:07:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:07:43 Integrated Voltage Measurement... 14:07:52 Voltage Offset Correction: v_off_ini = -117.967 uV, v_off_fin = -116.875 uV 14:07:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.606 uVs 14:07:52 Integrated Voltage Measurement... 14:08:01 Voltage Offset Correction: v_off_ini = -105.688 uV, v_off_fin = -81.657 uV 14:08:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.221 uVs 14:08:01 Integrated Voltage Measurement... 14:08:10 Voltage Offset Correction: v_off_ini = -102.553 uV, v_off_fin = -96.573 uV 14:08:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.032 uVs 14:08:10 Integrated Voltage Measurement... 14:08:19 Voltage Offset Correction: v_off_ini = -97.533 uV, v_off_fin = -83.559 uV 14:08:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 178.034 uVs 14:08:19 Integrated Voltage Measurement... 14:08:28 Voltage Offset Correction: v_off_ini = -92.600 uV, v_off_fin = -101.262 uV 14:08:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.917 uVs 14:08:28 Integrated Voltage Measurement... 14:08:37 Voltage Offset Correction: v_off_ini = -82.069 uV, v_off_fin = -79.064 uV 14:08:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.668 uVs 14:08:41 I1Y Average and RMS of Measurements VT = -163.413 +- 3.936 uVs I1Y = -32.683 +- 0.787 uTm 14:08:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:08:49 Integrated Voltage Measurement... 14:08:58 Voltage Offset Correction: v_off_ini = -77.534 uV, v_off_fin = -97.601 uV 14:08:58 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -89.453 uVs 14:08:58 Integrated Voltage Measurement... 14:09:07 Voltage Offset Correction: v_off_ini = -79.782 uV, v_off_fin = -82.913 uV 14:09:07 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 82.156 uVs 14:09:07 Integrated Voltage Measurement... 14:09:16 Voltage Offset Correction: v_off_ini = -86.683 uV, v_off_fin = -82.137 uV 14:09:16 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -69.841 uVs 14:09:16 Integrated Voltage Measurement... 14:09:25 Voltage Offset Correction: v_off_ini = -74.441 uV, v_off_fin = -55.672 uV 14:09:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.627 uVs 14:09:25 Integrated Voltage Measurement... 14:09:34 Voltage Offset Correction: v_off_ini = -61.421 uV, v_off_fin = -86.255 uV 14:09:34 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.738 uVs 14:09:34 Integrated Voltage Measurement... 14:09:43 Voltage Offset Correction: v_off_ini = -87.605 uV, v_off_fin = -62.125 uV 14:09:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.838 uVs 14:09:45 I2X Average and RMS of Measurements VT = -81.942 +- 2.741 uVs I2X = 7.539 +- 0.252 uTm^2 14:09:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:09:53 Integrated Voltage Measurement... 14:10:02 Voltage Offset Correction: v_off_ini = -60.988 uV, v_off_fin = -72.119 uV 14:10:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.049 uVs 14:10:02 Integrated Voltage Measurement... 14:10:11 Voltage Offset Correction: v_off_ini = -74.516 uV, v_off_fin = -76.520 uV 14:10:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.713 uVs 14:10:11 Integrated Voltage Measurement... 14:10:20 Voltage Offset Correction: v_off_ini = -86.645 uV, v_off_fin = -78.431 uV 14:10:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -144.679 uVs 14:10:20 Integrated Voltage Measurement... 14:10:29 Voltage Offset Correction: v_off_ini = -95.954 uV, v_off_fin = -83.893 uV 14:10:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 153.927 uVs 14:10:29 Integrated Voltage Measurement... 14:10:38 Voltage Offset Correction: v_off_ini = -89.474 uV, v_off_fin = -76.471 uV 14:10:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -142.053 uVs 14:10:38 Integrated Voltage Measurement... 14:10:47 Voltage Offset Correction: v_off_ini = -80.588 uV, v_off_fin = -63.483 uV 14:10:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 161.924 uVs 14:10:50 I2Y Average and RMS of Measurements VT = -154.224 +- 5.178 uVs I2Y = -14.189 +- 0.476 uTm^2 14:10:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:10:58 Integrated Voltage Measurement... 14:11:07 Voltage Offset Correction: v_off_ini = -64.308 uV, v_off_fin = -79.467 uV 14:11:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.818 uVs 14:11:08 Integrated Voltage Measurement... 14:11:16 Voltage Offset Correction: v_off_ini = -78.146 uV, v_off_fin = -69.588 uV 14:11:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.235 uVs 14:11:17 Integrated Voltage Measurement... 14:11:25 Voltage Offset Correction: v_off_ini = -63.763 uV, v_off_fin = -61.569 uV 14:11:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.434 uVs 14:11:26 Integrated Voltage Measurement... 14:11:35 Voltage Offset Correction: v_off_ini = -60.983 uV, v_off_fin = -55.040 uV 14:11:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.988 uVs 14:11:35 Integrated Voltage Measurement... 14:11:44 Voltage Offset Correction: v_off_ini = -64.673 uV, v_off_fin = -63.264 uV 14:11:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.542 uVs 14:11:44 Integrated Voltage Measurement... 14:11:53 Voltage Offset Correction: v_off_ini = -68.064 uV, v_off_fin = -62.421 uV 14:11:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.786 uVs 14:11:57 I1X Average and RMS of Measurements VT = -110.300 +- 2.580 uVs I1X = 22.060 +- 0.516 uTm 14:11:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:12:04 Integrated Voltage Measurement... 14:12:13 Voltage Offset Correction: v_off_ini = -48.855 uV, v_off_fin = -52.772 uV 14:12:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -172.376 uVs 14:12:13 Integrated Voltage Measurement... 14:12:22 Voltage Offset Correction: v_off_ini = -50.737 uV, v_off_fin = -51.912 uV 14:12:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.416 uVs 14:12:22 Integrated Voltage Measurement... 14:12:31 Voltage Offset Correction: v_off_ini = -61.501 uV, v_off_fin = -65.774 uV 14:12:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.010 uVs 14:12:31 Integrated Voltage Measurement... 14:12:40 Voltage Offset Correction: v_off_ini = -70.684 uV, v_off_fin = -69.335 uV 14:12:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.276 uVs 14:12:40 Integrated Voltage Measurement... 14:12:49 Voltage Offset Correction: v_off_ini = -56.264 uV, v_off_fin = -78.070 uV 14:12:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.974 uVs 14:12:49 Integrated Voltage Measurement... 14:12:58 Voltage Offset Correction: v_off_ini = -69.434 uV, v_off_fin = -66.468 uV 14:12:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.956 uVs 14:13:02 I1Y Average and RMS of Measurements VT = -160.501 +- 2.149 uVs I1Y = -32.100 +- 0.430 uTm 14:13:07 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:13:10 Integrated Voltage Measurement... 14:13:19 Voltage Offset Correction: v_off_ini = -96.816 uV, v_off_fin = -93.594 uV 14:13:19 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -92.996 uVs 14:13:19 Integrated Voltage Measurement... 14:13:28 Voltage Offset Correction: v_off_ini = -77.167 uV, v_off_fin = -78.204 uV 14:13:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.457 uVs 14:13:28 Integrated Voltage Measurement... 14:13:37 Voltage Offset Correction: v_off_ini = -81.640 uV, v_off_fin = -101.647 uV 14:13:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.926 uVs 14:13:37 Integrated Voltage Measurement... 14:13:46 Voltage Offset Correction: v_off_ini = -74.302 uV, v_off_fin = -65.858 uV 14:13:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 81.823 uVs 14:13:46 Integrated Voltage Measurement... 14:13:55 Voltage Offset Correction: v_off_ini = -73.588 uV, v_off_fin = -83.493 uV 14:13:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.699 uVs 14:13:55 Integrated Voltage Measurement... 14:14:04 Voltage Offset Correction: v_off_ini = -73.216 uV, v_off_fin = -72.820 uV 14:14:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.668 uVs 14:14:06 I2X Average and RMS of Measurements VT = -86.095 +- 0.552 uVs I2X = 7.921 +- 0.051 uTm^2 14:14:11 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:14:14 Integrated Voltage Measurement... 14:14:23 Voltage Offset Correction: v_off_ini = -91.486 uV, v_off_fin = -81.392 uV 14:14:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -117.602 uVs 14:14:23 Integrated Voltage Measurement... 14:14:32 Voltage Offset Correction: v_off_ini = -72.129 uV, v_off_fin = -72.041 uV 14:14:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 118.127 uVs 14:14:32 Integrated Voltage Measurement... 14:14:41 Voltage Offset Correction: v_off_ini = -69.544 uV, v_off_fin = -91.395 uV 14:14:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -153.285 uVs 14:14:41 Integrated Voltage Measurement... 14:14:50 Voltage Offset Correction: v_off_ini = -80.483 uV, v_off_fin = -81.432 uV 14:14:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 116.638 uVs 14:14:50 Integrated Voltage Measurement... 14:14:59 Voltage Offset Correction: v_off_ini = -91.323 uV, v_off_fin = -79.795 uV 14:14:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -113.669 uVs 14:14:59 Integrated Voltage Measurement... 14:15:08 Voltage Offset Correction: v_off_ini = -85.852 uV, v_off_fin = -76.621 uV 14:15:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 132.474 uVs 14:15:11 I2Y Average and RMS of Measurements VT = -125.299 +- 7.155 uVs I2Y = -11.528 +- 0.658 uTm^2 14:15:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:15:20 Integrated Voltage Measurement... 14:15:29 Voltage Offset Correction: v_off_ini = -55.452 uV, v_off_fin = -53.555 uV 14:15:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.310 uVs 14:15:29 Integrated Voltage Measurement... 14:15:38 Voltage Offset Correction: v_off_ini = -44.106 uV, v_off_fin = -67.022 uV 14:15:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.316 uVs 14:15:38 Integrated Voltage Measurement... 14:15:47 Voltage Offset Correction: v_off_ini = -56.534 uV, v_off_fin = -69.288 uV 14:15:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.566 uVs 14:15:47 Integrated Voltage Measurement... 14:15:56 Voltage Offset Correction: v_off_ini = -57.552 uV, v_off_fin = -51.617 uV 14:15:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.747 uVs 14:15:56 Integrated Voltage Measurement... 14:16:05 Voltage Offset Correction: v_off_ini = -63.992 uV, v_off_fin = -65.377 uV 14:16:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -112.860 uVs 14:16:05 Integrated Voltage Measurement... 14:16:14 Voltage Offset Correction: v_off_ini = -54.476 uV, v_off_fin = -53.824 uV 14:16:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 109.490 uVs 14:16:18 I1X Average and RMS of Measurements VT = -116.548 +- 3.900 uVs I1X = 23.310 +- 0.779 uTm 14:16:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:16:25 Integrated Voltage Measurement... 14:16:34 Voltage Offset Correction: v_off_ini = -47.269 uV, v_off_fin = -60.409 uV 14:16:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -139.207 uVs 14:16:34 Integrated Voltage Measurement... 14:16:43 Voltage Offset Correction: v_off_ini = -56.553 uV, v_off_fin = -43.858 uV 14:16:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.043 uVs 14:16:43 Integrated Voltage Measurement... 14:16:52 Voltage Offset Correction: v_off_ini = -49.491 uV, v_off_fin = -43.501 uV 14:16:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -141.065 uVs 14:16:52 Integrated Voltage Measurement... 14:17:01 Voltage Offset Correction: v_off_ini = -43.414 uV, v_off_fin = -20.079 uV 14:17:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.407 uVs 14:17:01 Integrated Voltage Measurement... 14:17:10 Voltage Offset Correction: v_off_ini = -17.395 uV, v_off_fin = -33.981 uV 14:17:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.066 uVs 14:17:10 Integrated Voltage Measurement... 14:17:19 Voltage Offset Correction: v_off_ini = -23.846 uV, v_off_fin = -27.116 uV 14:17:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 145.515 uVs 14:17:23 I1Y Average and RMS of Measurements VT = -152.217 +- 2.492 uVs I1Y = -30.443 +- 0.498 uTm 14:17:28 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:17:31 Integrated Voltage Measurement... 14:17:40 Voltage Offset Correction: v_off_ini = -38.659 uV, v_off_fin = -33.415 uV 14:17:40 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -101.360 uVs 14:17:40 Integrated Voltage Measurement... 14:17:49 Voltage Offset Correction: v_off_ini = -35.550 uV, v_off_fin = -19.741 uV 14:17:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.945 uVs 14:17:49 Integrated Voltage Measurement... 14:17:58 Voltage Offset Correction: v_off_ini = -34.612 uV, v_off_fin = -39.638 uV 14:17:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.264 uVs 14:17:58 Integrated Voltage Measurement... 14:18:07 Voltage Offset Correction: v_off_ini = -36.505 uV, v_off_fin = -21.048 uV 14:18:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.965 uVs 14:18:07 Integrated Voltage Measurement... 14:18:16 Voltage Offset Correction: v_off_ini = -35.712 uV, v_off_fin = -32.868 uV 14:18:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.814 uVs 14:18:16 Integrated Voltage Measurement... 14:18:25 Voltage Offset Correction: v_off_ini = -31.340 uV, v_off_fin = -20.405 uV 14:18:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.921 uVs 14:18:27 I2X Average and RMS of Measurements VT = -98.378 +- 2.658 uVs I2X = 9.050 +- 0.245 uTm^2 14:18:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:18:35 Integrated Voltage Measurement... 14:18:44 Voltage Offset Correction: v_off_ini = -23.864 uV, v_off_fin = -26.104 uV 14:18:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -127.104 uVs 14:18:44 Integrated Voltage Measurement... 14:18:53 Voltage Offset Correction: v_off_ini = -24.393 uV, v_off_fin = -21.254 uV 14:18:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 103.574 uVs 14:18:53 Integrated Voltage Measurement... 14:19:02 Voltage Offset Correction: v_off_ini = -13.603 uV, v_off_fin = -28.264 uV 14:19:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -135.275 uVs 14:19:02 Integrated Voltage Measurement... 14:19:11 Voltage Offset Correction: v_off_ini = -21.275 uV, v_off_fin = -28.088 uV 14:19:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 112.708 uVs 14:19:11 Integrated Voltage Measurement... 14:19:20 Voltage Offset Correction: v_off_ini = -20.853 uV, v_off_fin = -29.760 uV 14:19:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -126.861 uVs 14:19:20 Integrated Voltage Measurement... 14:19:29 Voltage Offset Correction: v_off_ini = -29.056 uV, v_off_fin = -14.780 uV 14:19:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 117.853 uVs 14:19:31 I2Y Average and RMS of Measurements VT = -120.563 +- 3.754 uVs I2Y = -11.092 +- 0.345 uTm^2 14:19:39 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:19:43 Integrated Voltage Measurement... 14:19:52 Voltage Offset Correction: v_off_ini = -6.692 uV, v_off_fin = -23.453 uV 14:19:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -79.089 uVs 14:19:52 Integrated Voltage Measurement... 14:20:01 Voltage Offset Correction: v_off_ini = -18.256 uV, v_off_fin = 1.420 uV 14:20:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.466 uVs 14:20:02 Integrated Voltage Measurement... 14:20:10 Voltage Offset Correction: v_off_ini = -5.115 uV, v_off_fin = -6.566 uV 14:20:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.333 uVs 14:20:11 Integrated Voltage Measurement... 14:20:20 Voltage Offset Correction: v_off_ini = -17.453 uV, v_off_fin = -2.763 uV 14:20:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.755 uVs 14:20:20 Integrated Voltage Measurement... 14:20:29 Voltage Offset Correction: v_off_ini = 7.501 uV, v_off_fin = -7.003 uV 14:20:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.966 uVs 14:20:29 Integrated Voltage Measurement... 14:20:38 Voltage Offset Correction: v_off_ini = -14.629 uV, v_off_fin = -14.508 uV 14:20:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.787 uVs 14:20:42 I1X Average and RMS of Measurements VT = -84.399 +- 4.351 uVs I1X = 16.881 +- 0.869 uTm 14:20:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:20:49 Integrated Voltage Measurement... 14:20:58 Voltage Offset Correction: v_off_ini = -16.091 uV, v_off_fin = -21.226 uV 14:20:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.477 uVs 14:20:58 Integrated Voltage Measurement... 14:21:07 Voltage Offset Correction: v_off_ini = -20.861 uV, v_off_fin = -7.932 uV 14:21:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 167.291 uVs 14:21:07 Integrated Voltage Measurement... 14:21:16 Voltage Offset Correction: v_off_ini = -10.015 uV, v_off_fin = -21.095 uV 14:21:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.098 uVs 14:21:16 Integrated Voltage Measurement... 14:21:25 Voltage Offset Correction: v_off_ini = -34.497 uV, v_off_fin = -29.446 uV 14:21:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.136 uVs 14:21:25 Integrated Voltage Measurement... 14:21:34 Voltage Offset Correction: v_off_ini = -20.265 uV, v_off_fin = -39.879 uV 14:21:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.578 uVs 14:21:34 Integrated Voltage Measurement... 14:21:43 Voltage Offset Correction: v_off_ini = -34.519 uV, v_off_fin = -23.941 uV 14:21:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.654 uVs 14:21:47 I1Y Average and RMS of Measurements VT = -170.039 +- 4.710 uVs I1Y = -34.008 +- 0.942 uTm 14:21:49 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:21:52 Integrated Voltage Measurement... 14:22:01 Voltage Offset Correction: v_off_ini = -42.150 uV, v_off_fin = -42.690 uV 14:22:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.335 uVs 14:22:01 Integrated Voltage Measurement... 14:22:10 Voltage Offset Correction: v_off_ini = -38.518 uV, v_off_fin = -32.878 uV 14:22:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 66.519 uVs 14:22:10 Integrated Voltage Measurement... 14:22:19 Voltage Offset Correction: v_off_ini = -35.422 uV, v_off_fin = -42.919 uV 14:22:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -59.866 uVs 14:22:19 Integrated Voltage Measurement... 14:22:28 Voltage Offset Correction: v_off_ini = -32.726 uV, v_off_fin = -26.920 uV 14:22:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.826 uVs 14:22:28 Integrated Voltage Measurement... 14:22:37 Voltage Offset Correction: v_off_ini = -41.541 uV, v_off_fin = -24.813 uV 14:22:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -75.234 uVs 14:22:37 Integrated Voltage Measurement... 14:22:46 Voltage Offset Correction: v_off_ini = -19.121 uV, v_off_fin = -17.277 uV 14:22:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.341 uVs 14:22:49 I2X Average and RMS of Measurements VT = -64.187 +- 4.447 uVs I2X = 5.906 +- 0.409 uTm^2 14:22:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:22:54 Integrated Voltage Measurement... 14:23:03 Voltage Offset Correction: v_off_ini = -30.604 uV, v_off_fin = -35.222 uV 14:23:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -129.713 uVs 14:23:03 Integrated Voltage Measurement... 14:23:12 Voltage Offset Correction: v_off_ini = -14.435 uV, v_off_fin = -9.519 uV 14:23:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 120.183 uVs 14:23:12 Integrated Voltage Measurement... 14:23:21 Voltage Offset Correction: v_off_ini = -20.825 uV, v_off_fin = -16.397 uV 14:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -141.143 uVs 14:23:21 Integrated Voltage Measurement... 14:23:30 Voltage Offset Correction: v_off_ini = -2.272 uV, v_off_fin = -16.499 uV 14:23:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 127.235 uVs 14:23:30 Integrated Voltage Measurement... 14:23:39 Voltage Offset Correction: v_off_ini = -18.845 uV, v_off_fin = -21.375 uV 14:23:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -137.433 uVs 14:23:39 Integrated Voltage Measurement... 14:23:48 Voltage Offset Correction: v_off_ini = -27.431 uV, v_off_fin = -26.017 uV 14:23:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 113.629 uVs 14:23:50 I2Y Average and RMS of Measurements VT = -128.223 +- 4.226 uVs I2Y = -11.796 +- 0.389 uTm^2 14:23:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:23:59 Integrated Voltage Measurement... 14:24:07 Voltage Offset Correction: v_off_ini = -17.687 uV, v_off_fin = -21.108 uV 14:24:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.747 uVs 14:24:08 Integrated Voltage Measurement... 14:24:16 Voltage Offset Correction: v_off_ini = -6.215 uV, v_off_fin = -8.300 uV 14:24:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.778 uVs 14:24:17 Integrated Voltage Measurement... 14:24:25 Voltage Offset Correction: v_off_ini = -22.345 uV, v_off_fin = -32.665 uV 14:24:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.772 uVs 14:24:26 Integrated Voltage Measurement... 14:24:35 Voltage Offset Correction: v_off_ini = -15.061 uV, v_off_fin = -12.351 uV 14:24:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.544 uVs 14:24:35 Integrated Voltage Measurement... 14:24:44 Voltage Offset Correction: v_off_ini = -20.506 uV, v_off_fin = -17.529 uV 14:24:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.341 uVs 14:24:44 Integrated Voltage Measurement... 14:24:53 Voltage Offset Correction: v_off_ini = -18.320 uV, v_off_fin = -18.511 uV 14:24:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.357 uVs 14:24:57 I1X Average and RMS of Measurements VT = -88.590 +- 6.857 uVs I1X = 17.718 +- 1.371 uTm 14:24:59 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:25:04 Integrated Voltage Measurement... 14:25:13 Voltage Offset Correction: v_off_ini = -19.554 uV, v_off_fin = -23.802 uV 14:25:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.657 uVs 14:25:13 Integrated Voltage Measurement... 14:25:22 Voltage Offset Correction: v_off_ini = 0.161 uV, v_off_fin = -6.653 uV 14:25:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.367 uVs 14:25:22 Integrated Voltage Measurement... 14:25:31 Voltage Offset Correction: v_off_ini = -16.600 uV, v_off_fin = 2.525 uV 14:25:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -159.996 uVs 14:25:31 Integrated Voltage Measurement... 14:25:40 Voltage Offset Correction: v_off_ini = 11.808 uV, v_off_fin = 9.560 uV 14:25:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.818 uVs 14:25:40 Integrated Voltage Measurement... 14:25:49 Voltage Offset Correction: v_off_ini = -9.956 uV, v_off_fin = -13.753 uV 14:25:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.137 uVs 14:25:49 Integrated Voltage Measurement... 14:25:58 Voltage Offset Correction: v_off_ini = 2.934 uV, v_off_fin = 7.276 uV 14:25:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.399 uVs 14:26:02 I1Y Average and RMS of Measurements VT = -172.229 +- 6.001 uVs I1Y = -34.446 +- 1.200 uTm 14:26:04 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:26:07 Integrated Voltage Measurement... 14:26:16 Voltage Offset Correction: v_off_ini = -1.494 uV, v_off_fin = -23.306 uV 14:26:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.759 uVs 14:26:16 Integrated Voltage Measurement... 14:26:25 Voltage Offset Correction: v_off_ini = -11.550 uV, v_off_fin = 18.867 uV 14:26:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.903 uVs 14:26:25 Integrated Voltage Measurement... 14:26:34 Voltage Offset Correction: v_off_ini = -11.987 uV, v_off_fin = -17.624 uV 14:26:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.028 uVs 14:26:34 Integrated Voltage Measurement... 14:26:43 Voltage Offset Correction: v_off_ini = -4.648 uV, v_off_fin = -2.800 uV 14:26:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.642 uVs 14:26:43 Integrated Voltage Measurement... 14:26:52 Voltage Offset Correction: v_off_ini = -4.792 uV, v_off_fin = -21.774 uV 14:26:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.480 uVs 14:26:52 Integrated Voltage Measurement... 14:27:01 Voltage Offset Correction: v_off_ini = 7.133 uV, v_off_fin = 11.433 uV 14:27:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.879 uVs 14:27:04 I2X Average and RMS of Measurements VT = -70.949 +- 4.576 uVs I2X = 6.527 +- 0.421 uTm^2 14:27:06 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:27:09 Integrated Voltage Measurement... 14:27:18 Voltage Offset Correction: v_off_ini = -9.704 uV, v_off_fin = -18.316 uV 14:27:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -134.043 uVs 14:27:18 Integrated Voltage Measurement... 14:27:27 Voltage Offset Correction: v_off_ini = -10.395 uV, v_off_fin = -12.193 uV 14:27:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 161.501 uVs 14:27:27 Integrated Voltage Measurement... 14:27:36 Voltage Offset Correction: v_off_ini = -5.460 uV, v_off_fin = -1.419 uV 14:27:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -138.775 uVs 14:27:36 Integrated Voltage Measurement... 14:27:45 Voltage Offset Correction: v_off_ini = -7.961 uV, v_off_fin = -12.001 uV 14:27:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 142.421 uVs 14:27:45 Integrated Voltage Measurement... 14:27:54 Voltage Offset Correction: v_off_ini = -17.348 uV, v_off_fin = -9.918 uV 14:27:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -155.823 uVs 14:27:54 Integrated Voltage Measurement... 14:28:03 Voltage Offset Correction: v_off_ini = 0.473 uV, v_off_fin = 1.107 uV 14:28:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 135.634 uVs 14:28:05 I2Y Average and RMS of Measurements VT = -144.699 +- 3.018 uVs I2Y = -13.312 +- 0.278 uTm^2 14:28:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:28:14 Integrated Voltage Measurement... 14:28:23 Voltage Offset Correction: v_off_ini = -3.120 uV, v_off_fin = -12.274 uV 14:28:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -111.981 uVs 14:28:23 Integrated Voltage Measurement... 14:28:32 Voltage Offset Correction: v_off_ini = -18.544 uV, v_off_fin = -15.265 uV 14:28:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.116 uVs 14:28:32 Integrated Voltage Measurement... 14:28:41 Voltage Offset Correction: v_off_ini = -9.670 uV, v_off_fin = -19.120 uV 14:28:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.477 uVs 14:28:41 Integrated Voltage Measurement... 14:28:50 Voltage Offset Correction: v_off_ini = -9.778 uV, v_off_fin = -2.083 uV 14:28:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.579 uVs 14:28:50 Integrated Voltage Measurement... 14:28:59 Voltage Offset Correction: v_off_ini = -9.369 uV, v_off_fin = -19.329 uV 14:28:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.996 uVs 14:28:59 Integrated Voltage Measurement... 14:29:08 Voltage Offset Correction: v_off_ini = -18.389 uV, v_off_fin = -8.624 uV 14:29:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.928 uVs 14:29:12 I1X Average and RMS of Measurements VT = -107.346 +- 1.423 uVs I1X = 21.470 +- 0.283 uTm 14:29:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:29:19 Integrated Voltage Measurement... 14:29:28 Voltage Offset Correction: v_off_ini = -3.856 uV, v_off_fin = -9.734 uV 14:29:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.623 uVs 14:29:28 Integrated Voltage Measurement... 14:29:37 Voltage Offset Correction: v_off_ini = -7.844 uV, v_off_fin = 4.253 uV 14:29:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 158.574 uVs 14:29:37 Integrated Voltage Measurement... 14:29:46 Voltage Offset Correction: v_off_ini = -22.672 uV, v_off_fin = -38.491 uV 14:29:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.059 uVs 14:29:46 Integrated Voltage Measurement... 14:29:55 Voltage Offset Correction: v_off_ini = -13.767 uV, v_off_fin = -5.223 uV 14:29:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 162.640 uVs 14:29:55 Integrated Voltage Measurement... 14:30:04 Voltage Offset Correction: v_off_ini = -23.398 uV, v_off_fin = -31.713 uV 14:30:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -160.463 uVs 14:30:04 Integrated Voltage Measurement... 14:30:13 Voltage Offset Correction: v_off_ini = -34.751 uV, v_off_fin = -22.001 uV 14:30:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 163.731 uVs 14:30:17 I1Y Average and RMS of Measurements VT = -166.181 +- 3.269 uVs I1Y = -33.236 +- 0.654 uTm 14:30:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:30:22 Integrated Voltage Measurement... 14:30:31 Voltage Offset Correction: v_off_ini = -33.554 uV, v_off_fin = -38.764 uV 14:30:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.812 uVs 14:30:31 Integrated Voltage Measurement... 14:30:40 Voltage Offset Correction: v_off_ini = -42.730 uV, v_off_fin = -29.065 uV 14:30:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.545 uVs 14:30:40 Integrated Voltage Measurement... 14:30:49 Voltage Offset Correction: v_off_ini = -48.602 uV, v_off_fin = -42.683 uV 14:30:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.708 uVs 14:30:49 Integrated Voltage Measurement... 14:30:58 Voltage Offset Correction: v_off_ini = -40.913 uV, v_off_fin = -30.899 uV 14:30:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.092 uVs 14:30:58 Integrated Voltage Measurement... 14:31:07 Voltage Offset Correction: v_off_ini = -41.276 uV, v_off_fin = -47.237 uV 14:31:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.626 uVs 14:31:07 Integrated Voltage Measurement... 14:31:16 Voltage Offset Correction: v_off_ini = -22.712 uV, v_off_fin = -23.021 uV 14:31:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.203 uVs 14:31:19 I2X Average and RMS of Measurements VT = -86.664 +- 5.690 uVs I2X = 7.973 +- 0.523 uTm^2 14:31:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:31:24 Integrated Voltage Measurement... 14:31:33 Voltage Offset Correction: v_off_ini = -40.772 uV, v_off_fin = -48.724 uV 14:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -141.098 uVs 14:31:33 Integrated Voltage Measurement... 14:31:42 Voltage Offset Correction: v_off_ini = -35.134 uV, v_off_fin = -33.671 uV 14:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 146.615 uVs 14:31:42 Integrated Voltage Measurement... 14:31:51 Voltage Offset Correction: v_off_ini = -43.811 uV, v_off_fin = -40.324 uV 14:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -145.218 uVs 14:31:51 Integrated Voltage Measurement... 14:32:00 Voltage Offset Correction: v_off_ini = -30.032 uV, v_off_fin = -38.000 uV 14:32:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 126.975 uVs 14:32:00 Integrated Voltage Measurement... 14:32:09 Voltage Offset Correction: v_off_ini = -18.700 uV, v_off_fin = -39.085 uV 14:32:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -153.602 uVs 14:32:09 Integrated Voltage Measurement... 14:32:18 Voltage Offset Correction: v_off_ini = -37.861 uV, v_off_fin = -29.722 uV 14:32:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 151.576 uVs 14:32:20 I2Y Average and RMS of Measurements VT = -144.181 +- 6.737 uVs I2Y = -13.265 +- 0.620 uTm^2 14:32:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:32:29 Integrated Voltage Measurement... 14:32:38 Voltage Offset Correction: v_off_ini = -58.725 uV, v_off_fin = -49.568 uV 14:32:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -121.492 uVs 14:32:38 Integrated Voltage Measurement... 14:32:47 Voltage Offset Correction: v_off_ini = -34.712 uV, v_off_fin = -15.557 uV 14:32:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 112.763 uVs 14:32:47 Integrated Voltage Measurement... 14:32:56 Voltage Offset Correction: v_off_ini = -13.077 uV, v_off_fin = -23.995 uV 14:32:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.021 uVs 14:32:56 Integrated Voltage Measurement... 14:33:05 Voltage Offset Correction: v_off_ini = -19.608 uV, v_off_fin = -15.835 uV 14:33:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.607 uVs 14:33:05 Integrated Voltage Measurement... 14:33:14 Voltage Offset Correction: v_off_ini = -37.367 uV, v_off_fin = -45.707 uV 14:33:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.318 uVs 14:33:14 Integrated Voltage Measurement... 14:33:23 Voltage Offset Correction: v_off_ini = -45.504 uV, v_off_fin = -32.045 uV 14:33:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.805 uVs 14:33:27 I1X Average and RMS of Measurements VT = -107.001 +- 7.601 uVs I1X = 21.401 +- 1.521 uTm 14:33:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:33:34 Integrated Voltage Measurement... 14:33:43 Voltage Offset Correction: v_off_ini = -46.925 uV, v_off_fin = -28.375 uV 14:33:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -170.951 uVs 14:33:43 Integrated Voltage Measurement... 14:33:52 Voltage Offset Correction: v_off_ini = -31.668 uV, v_off_fin = -27.176 uV 14:33:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.899 uVs 14:33:52 Integrated Voltage Measurement... 14:34:01 Voltage Offset Correction: v_off_ini = -36.601 uV, v_off_fin = -47.715 uV 14:34:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.195 uVs 14:34:01 Integrated Voltage Measurement... 14:34:10 Voltage Offset Correction: v_off_ini = -23.802 uV, v_off_fin = -20.912 uV 14:34:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 168.422 uVs 14:34:10 Integrated Voltage Measurement... 14:34:19 Voltage Offset Correction: v_off_ini = -43.135 uV, v_off_fin = -31.627 uV 14:34:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -154.927 uVs 14:34:19 Integrated Voltage Measurement... 14:34:28 Voltage Offset Correction: v_off_ini = -30.003 uV, v_off_fin = -15.743 uV 14:34:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.738 uVs 14:34:32 I1Y Average and RMS of Measurements VT = -167.856 +- 6.570 uVs I1Y = -33.571 +- 1.314 uTm 14:34:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:34:37 Integrated Voltage Measurement... 14:34:46 Voltage Offset Correction: v_off_ini = -22.954 uV, v_off_fin = -19.983 uV 14:34:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.679 uVs 14:34:46 Integrated Voltage Measurement... 14:34:55 Voltage Offset Correction: v_off_ini = -23.423 uV, v_off_fin = -23.180 uV 14:34:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.968 uVs 14:34:55 Integrated Voltage Measurement... 14:35:04 Voltage Offset Correction: v_off_ini = -25.731 uV, v_off_fin = -16.905 uV 14:35:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.886 uVs 14:35:04 Integrated Voltage Measurement... 14:35:13 Voltage Offset Correction: v_off_ini = -15.074 uV, v_off_fin = -2.920 uV 14:35:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.631 uVs 14:35:13 Integrated Voltage Measurement... 14:35:22 Voltage Offset Correction: v_off_ini = 6.211 uV, v_off_fin = -9.934 uV 14:35:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.705 uVs 14:35:22 Integrated Voltage Measurement... 14:35:31 Voltage Offset Correction: v_off_ini = -11.953 uV, v_off_fin = -23.749 uV 14:35:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.018 uVs 14:35:34 I2X Average and RMS of Measurements VT = -94.981 +- 7.064 uVs I2X = 8.738 +- 0.650 uTm^2 14:35:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:35:39 Integrated Voltage Measurement... 14:35:48 Voltage Offset Correction: v_off_ini = -23.804 uV, v_off_fin = -35.846 uV 14:35:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -134.993 uVs 14:35:48 Integrated Voltage Measurement... 14:35:57 Voltage Offset Correction: v_off_ini = -25.153 uV, v_off_fin = -16.231 uV 14:35:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.267 uVs 14:35:57 Integrated Voltage Measurement... 14:36:06 Voltage Offset Correction: v_off_ini = -20.939 uV, v_off_fin = -21.191 uV 14:36:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -156.576 uVs 14:36:06 Integrated Voltage Measurement... 14:36:15 Voltage Offset Correction: v_off_ini = -27.394 uV, v_off_fin = -45.915 uV 14:36:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.485 uVs 14:36:15 Integrated Voltage Measurement... 14:36:24 Voltage Offset Correction: v_off_ini = -57.493 uV, v_off_fin = -53.646 uV 14:36:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -139.632 uVs 14:36:24 Integrated Voltage Measurement... 14:36:33 Voltage Offset Correction: v_off_ini = -45.264 uV, v_off_fin = -47.491 uV 14:36:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 137.393 uVs 14:36:36 I2Y Average and RMS of Measurements VT = -148.391 +- 8.627 uVs I2Y = -13.652 +- 0.794 uTm^2 14:36:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:36:44 Integrated Voltage Measurement... 14:36:53 Voltage Offset Correction: v_off_ini = -32.750 uV, v_off_fin = -41.358 uV 14:36:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -128.851 uVs 14:36:53 Integrated Voltage Measurement... 14:37:02 Voltage Offset Correction: v_off_ini = -32.430 uV, v_off_fin = -23.319 uV 14:37:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.124 uVs 14:37:02 Integrated Voltage Measurement... 14:37:11 Voltage Offset Correction: v_off_ini = -23.239 uV, v_off_fin = -32.047 uV 14:37:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -92.144 uVs 14:37:11 Integrated Voltage Measurement... 14:37:20 Voltage Offset Correction: v_off_ini = -19.401 uV, v_off_fin = -21.434 uV 14:37:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.300 uVs 14:37:20 Integrated Voltage Measurement... 14:37:29 Voltage Offset Correction: v_off_ini = -13.180 uV, v_off_fin = -25.530 uV 14:37:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.851 uVs 14:37:29 Integrated Voltage Measurement... 14:37:38 Voltage Offset Correction: v_off_ini = -29.951 uV, v_off_fin = -15.239 uV 14:37:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.871 uVs 14:37:42 I1X Average and RMS of Measurements VT = -114.024 +- 6.893 uVs I1X = 22.806 +- 1.379 uTm 14:37:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:37:49 Integrated Voltage Measurement... 14:37:58 Voltage Offset Correction: v_off_ini = -32.167 uV, v_off_fin = -47.055 uV 14:37:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -180.644 uVs 14:37:58 Integrated Voltage Measurement... 14:38:07 Voltage Offset Correction: v_off_ini = -41.153 uV, v_off_fin = -16.526 uV 14:38:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 183.999 uVs 14:38:07 Integrated Voltage Measurement... 14:38:16 Voltage Offset Correction: v_off_ini = -30.819 uV, v_off_fin = -48.334 uV 14:38:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.379 uVs 14:38:16 Integrated Voltage Measurement... 14:38:25 Voltage Offset Correction: v_off_ini = -44.281 uV, v_off_fin = -25.781 uV 14:38:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 181.726 uVs 14:38:25 Integrated Voltage Measurement... 14:38:34 Voltage Offset Correction: v_off_ini = -43.645 uV, v_off_fin = -43.328 uV 14:38:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -178.189 uVs 14:38:34 Integrated Voltage Measurement... 14:38:43 Voltage Offset Correction: v_off_ini = -35.931 uV, v_off_fin = -18.957 uV 14:38:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.906 uVs 14:38:47 I1Y Average and RMS of Measurements VT = -181.474 +- 1.011 uVs I1Y = -36.291 +- 0.202 uTm 14:38:50 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:38:52 Integrated Voltage Measurement... 14:39:01 Voltage Offset Correction: v_off_ini = -27.309 uV, v_off_fin = -34.224 uV 14:39:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.875 uVs 14:39:01 Integrated Voltage Measurement... 14:39:10 Voltage Offset Correction: v_off_ini = -28.465 uV, v_off_fin = -17.627 uV 14:39:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.708 uVs 14:39:10 Integrated Voltage Measurement... 14:39:19 Voltage Offset Correction: v_off_ini = -23.035 uV, v_off_fin = -27.162 uV 14:39:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.279 uVs 14:39:19 Integrated Voltage Measurement... 14:39:28 Voltage Offset Correction: v_off_ini = -14.493 uV, v_off_fin = -12.716 uV 14:39:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.957 uVs 14:39:28 Integrated Voltage Measurement... 14:39:37 Voltage Offset Correction: v_off_ini = -14.504 uV, v_off_fin = -19.566 uV 14:39:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.659 uVs 14:39:37 Integrated Voltage Measurement... 14:39:46 Voltage Offset Correction: v_off_ini = -14.141 uV, v_off_fin = -1.612 uV 14:39:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.966 uVs 14:39:49 I2X Average and RMS of Measurements VT = -95.074 +- 8.203 uVs I2X = 8.747 +- 0.755 uTm^2 14:39:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:39:54 Integrated Voltage Measurement... 14:40:03 Voltage Offset Correction: v_off_ini = -9.171 uV, v_off_fin = -7.606 uV 14:40:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -138.543 uVs 14:40:03 Integrated Voltage Measurement... 14:40:12 Voltage Offset Correction: v_off_ini = -9.485 uV, v_off_fin = -10.193 uV 14:40:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 130.627 uVs 14:40:12 Integrated Voltage Measurement... 14:40:21 Voltage Offset Correction: v_off_ini = -15.273 uV, v_off_fin = -12.577 uV 14:40:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -139.112 uVs 14:40:21 Integrated Voltage Measurement... 14:40:30 Voltage Offset Correction: v_off_ini = -15.868 uV, v_off_fin = -9.711 uV 14:40:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 126.565 uVs 14:40:30 Integrated Voltage Measurement... 14:40:39 Voltage Offset Correction: v_off_ini = -22.088 uV, v_off_fin = -14.254 uV 14:40:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -147.706 uVs 14:40:39 Integrated Voltage Measurement... 14:40:48 Voltage Offset Correction: v_off_ini = -1.204 uV, v_off_fin = -11.365 uV 14:40:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 143.599 uVs 14:40:51 I2Y Average and RMS of Measurements VT = -137.692 +- 5.674 uVs I2Y = -12.668 +- 0.522 uTm^2 14:41:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:41:11 Integrated Voltage Measurement... 14:41:20 Voltage Offset Correction: v_off_ini = -16.831 uV, v_off_fin = -18.667 uV 14:41:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.288 uVs 14:41:20 Integrated Voltage Measurement... 14:41:29 Voltage Offset Correction: v_off_ini = -17.736 uV, v_off_fin = -21.863 uV 14:41:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.424 uVs 14:41:29 Integrated Voltage Measurement... 14:41:38 Voltage Offset Correction: v_off_ini = 5.107 uV, v_off_fin = 6.022 uV 14:41:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.184 uVs 14:41:38 Integrated Voltage Measurement... 14:41:47 Voltage Offset Correction: v_off_ini = 14.244 uV, v_off_fin = 29.046 uV 14:41:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.478 uVs 14:41:47 Integrated Voltage Measurement... 14:41:56 Voltage Offset Correction: v_off_ini = 14.682 uV, v_off_fin = 12.015 uV 14:41:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -102.678 uVs 14:41:56 Integrated Voltage Measurement... 14:42:05 Voltage Offset Correction: v_off_ini = 0.539 uV, v_off_fin = 10.725 uV 14:42:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 73.513 uVs 14:42:09 I1X Average and RMS of Measurements VT = -88.094 +- 2.255 uVs I1X = 17.620 +- 0.451 uTm 14:42:12 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:42:16 Integrated Voltage Measurement... 14:42:25 Voltage Offset Correction: v_off_ini = -8.036 uV, v_off_fin = -19.054 uV 14:42:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.035 uVs 14:42:25 Integrated Voltage Measurement... 14:42:34 Voltage Offset Correction: v_off_ini = 1.502 uV, v_off_fin = 5.377 uV 14:42:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.041 uVs 14:42:34 Integrated Voltage Measurement... 14:42:43 Voltage Offset Correction: v_off_ini = -7.651 uV, v_off_fin = -26.908 uV 14:42:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.931 uVs 14:42:43 Integrated Voltage Measurement... 14:42:52 Voltage Offset Correction: v_off_ini = -1.174 uV, v_off_fin = -3.932 uV 14:42:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.936 uVs 14:42:52 Integrated Voltage Measurement... 14:43:01 Voltage Offset Correction: v_off_ini = -12.643 uV, v_off_fin = -29.421 uV 14:43:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.026 uVs 14:43:01 Integrated Voltage Measurement... 14:43:10 Voltage Offset Correction: v_off_ini = -14.276 uV, v_off_fin = 4.821 uV 14:43:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.126 uVs 14:43:14 I1Y Average and RMS of Measurements VT = -227.849 +- 4.384 uVs I1Y = -45.570 +- 0.877 uTm 14:43:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:43:22 Integrated Voltage Measurement... 14:43:31 Voltage Offset Correction: v_off_ini = -8.589 uV, v_off_fin = -22.881 uV 14:43:31 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -65.430 uVs 14:43:31 Integrated Voltage Measurement... 14:43:40 Voltage Offset Correction: v_off_ini = -5.796 uV, v_off_fin = 12.504 uV 14:43:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 44.532 uVs 14:43:40 Integrated Voltage Measurement... 14:43:49 Voltage Offset Correction: v_off_ini = -3.426 uV, v_off_fin = -7.774 uV 14:43:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -50.547 uVs 14:43:49 Integrated Voltage Measurement... 14:43:58 Voltage Offset Correction: v_off_ini = -3.833 uV, v_off_fin = 1.032 uV 14:43:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.153 uVs 14:43:58 Integrated Voltage Measurement... 14:44:07 Voltage Offset Correction: v_off_ini = 7.659 uV, v_off_fin = 2.390 uV 14:44:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.970 uVs 14:44:07 Integrated Voltage Measurement... 14:44:16 Voltage Offset Correction: v_off_ini = -2.942 uV, v_off_fin = 6.617 uV 14:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.641 uVs 14:44:18 I2X Average and RMS of Measurements VT = -59.046 +- 2.883 uVs I2X = 5.432 +- 0.265 uTm^2 14:44:23 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:44:26 Integrated Voltage Measurement... 14:44:35 Voltage Offset Correction: v_off_ini = -1.842 uV, v_off_fin = 2.110 uV 14:44:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.982 uVs 14:44:35 Integrated Voltage Measurement... 14:44:44 Voltage Offset Correction: v_off_ini = -13.557 uV, v_off_fin = -9.316 uV 14:44:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.251 uVs 14:44:44 Integrated Voltage Measurement... 14:44:53 Voltage Offset Correction: v_off_ini = -14.513 uV, v_off_fin = -2.740 uV 14:44:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.361 uVs 14:44:53 Integrated Voltage Measurement... 14:45:02 Voltage Offset Correction: v_off_ini = 13.323 uV, v_off_fin = 16.827 uV 14:45:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.549 uVs 14:45:02 Integrated Voltage Measurement... 14:45:11 Voltage Offset Correction: v_off_ini = 13.364 uV, v_off_fin = 19.203 uV 14:45:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.293 uVs 14:45:11 Integrated Voltage Measurement... 14:45:20 Voltage Offset Correction: v_off_ini = 8.072 uV, v_off_fin = 17.853 uV 14:45:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.010 uVs 14:45:23 I2Y Average and RMS of Measurements VT = -206.075 +- 8.910 uVs I2Y = -18.959 +- 0.820 uTm^2 14:45:27 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:45:32 Integrated Voltage Measurement... 14:45:41 Voltage Offset Correction: v_off_ini = 30.243 uV, v_off_fin = 19.227 uV 14:45:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -112.809 uVs 14:45:41 Integrated Voltage Measurement... 14:45:50 Voltage Offset Correction: v_off_ini = 20.697 uV, v_off_fin = 23.127 uV 14:45:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.970 uVs 14:45:50 Integrated Voltage Measurement... 14:45:59 Voltage Offset Correction: v_off_ini = 24.110 uV, v_off_fin = 28.202 uV 14:45:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -86.913 uVs 14:45:59 Integrated Voltage Measurement... 14:46:08 Voltage Offset Correction: v_off_ini = 31.659 uV, v_off_fin = 23.873 uV 14:46:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.701 uVs 14:46:08 Integrated Voltage Measurement... 14:46:17 Voltage Offset Correction: v_off_ini = 23.630 uV, v_off_fin = 25.061 uV 14:46:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.372 uVs 14:46:17 Integrated Voltage Measurement... 14:46:26 Voltage Offset Correction: v_off_ini = 21.978 uV, v_off_fin = 34.356 uV 14:46:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.207 uVs 14:46:30 I1X Average and RMS of Measurements VT = -91.662 +- 1.970 uVs I1X = 18.333 +- 0.394 uTm 14:46:32 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:46:37 Integrated Voltage Measurement... 14:46:46 Voltage Offset Correction: v_off_ini = 39.289 uV, v_off_fin = 20.246 uV 14:46:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.282 uVs 14:46:46 Integrated Voltage Measurement... 14:46:55 Voltage Offset Correction: v_off_ini = 13.899 uV, v_off_fin = 17.851 uV 14:46:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.767 uVs 14:46:55 Integrated Voltage Measurement... 14:47:04 Voltage Offset Correction: v_off_ini = 13.087 uV, v_off_fin = 14.244 uV 14:47:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.538 uVs 14:47:04 Integrated Voltage Measurement... 14:47:13 Voltage Offset Correction: v_off_ini = 17.095 uV, v_off_fin = 23.665 uV 14:47:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.823 uVs 14:47:13 Integrated Voltage Measurement... 14:47:22 Voltage Offset Correction: v_off_ini = 20.958 uV, v_off_fin = 13.772 uV 14:47:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.279 uVs 14:47:22 Integrated Voltage Measurement... 14:47:31 Voltage Offset Correction: v_off_ini = 26.754 uV, v_off_fin = 27.405 uV 14:47:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.012 uVs 14:47:35 I1Y Average and RMS of Measurements VT = -210.784 +- 0.917 uVs I1Y = -42.157 +- 0.183 uTm 14:47:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:47:43 Integrated Voltage Measurement... 14:47:52 Voltage Offset Correction: v_off_ini = 24.556 uV, v_off_fin = 24.615 uV 14:47:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -71.292 uVs 14:47:52 Integrated Voltage Measurement... 14:48:01 Voltage Offset Correction: v_off_ini = 33.195 uV, v_off_fin = 27.094 uV 14:48:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.820 uVs 14:48:01 Integrated Voltage Measurement... 14:48:10 Voltage Offset Correction: v_off_ini = 20.823 uV, v_off_fin = 7.091 uV 14:48:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.715 uVs 14:48:10 Integrated Voltage Measurement... 14:48:19 Voltage Offset Correction: v_off_ini = 21.486 uV, v_off_fin = 34.588 uV 14:48:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.427 uVs 14:48:19 Integrated Voltage Measurement... 14:48:28 Voltage Offset Correction: v_off_ini = 20.377 uV, v_off_fin = 18.419 uV 14:48:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.017 uVs 14:48:28 Integrated Voltage Measurement... 14:48:37 Voltage Offset Correction: v_off_ini = 30.440 uV, v_off_fin = 34.166 uV 14:48:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.662 uVs 14:48:39 I2X Average and RMS of Measurements VT = -59.156 +- 7.714 uVs I2X = 5.442 +- 0.709 uTm^2 14:48:44 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:48:47 Integrated Voltage Measurement... 14:48:56 Voltage Offset Correction: v_off_ini = 12.320 uV, v_off_fin = 17.801 uV 14:48:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.252 uVs 14:48:56 Integrated Voltage Measurement... 14:49:05 Voltage Offset Correction: v_off_ini = 28.538 uV, v_off_fin = 22.649 uV 14:49:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.153 uVs 14:49:05 Integrated Voltage Measurement... 14:49:14 Voltage Offset Correction: v_off_ini = 25.485 uV, v_off_fin = 34.077 uV 14:49:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -175.317 uVs 14:49:14 Integrated Voltage Measurement... 14:49:23 Voltage Offset Correction: v_off_ini = 28.722 uV, v_off_fin = 27.928 uV 14:49:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.261 uVs 14:49:23 Integrated Voltage Measurement... 14:49:32 Voltage Offset Correction: v_off_ini = 20.588 uV, v_off_fin = 20.459 uV 14:49:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.614 uVs 14:49:32 Integrated Voltage Measurement... 14:49:41 Voltage Offset Correction: v_off_ini = 47.235 uV, v_off_fin = 31.888 uV 14:49:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.871 uVs 14:49:44 I2Y Average and RMS of Measurements VT = -184.745 +- 3.586 uVs I2Y = -16.997 +- 0.330 uTm^2 14:49:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:49:53 Integrated Voltage Measurement... 14:50:01 Voltage Offset Correction: v_off_ini = 22.282 uV, v_off_fin = 10.829 uV 14:50:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.416 uVs 14:50:02 Integrated Voltage Measurement... 14:50:10 Voltage Offset Correction: v_off_ini = 13.196 uV, v_off_fin = 27.013 uV 14:50:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.035 uVs 14:50:11 Integrated Voltage Measurement... 14:50:20 Voltage Offset Correction: v_off_ini = 18.880 uV, v_off_fin = 13.057 uV 14:50:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.986 uVs 14:50:20 Integrated Voltage Measurement... 14:50:29 Voltage Offset Correction: v_off_ini = 17.780 uV, v_off_fin = 18.774 uV 14:50:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.219 uVs 14:50:29 Integrated Voltage Measurement... 14:50:38 Voltage Offset Correction: v_off_ini = 25.845 uV, v_off_fin = 10.049 uV 14:50:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.279 uVs 14:50:38 Integrated Voltage Measurement... 14:50:47 Voltage Offset Correction: v_off_ini = 31.605 uV, v_off_fin = 29.299 uV 14:50:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.343 uVs 14:50:51 I1X Average and RMS of Measurements VT = -102.380 +- 11.593 uVs I1X = 20.476 +- 2.319 uTm 14:50:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:50:58 Integrated Voltage Measurement... 14:51:07 Voltage Offset Correction: v_off_ini = 2.663 uV, v_off_fin = 2.875 uV 14:51:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.264 uVs 14:51:07 Integrated Voltage Measurement... 14:51:16 Voltage Offset Correction: v_off_ini = 26.913 uV, v_off_fin = 25.706 uV 14:51:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.307 uVs 14:51:16 Integrated Voltage Measurement... 14:51:25 Voltage Offset Correction: v_off_ini = 20.130 uV, v_off_fin = 11.479 uV 14:51:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.147 uVs 14:51:25 Integrated Voltage Measurement... 14:51:34 Voltage Offset Correction: v_off_ini = 26.741 uV, v_off_fin = 42.757 uV 14:51:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.135 uVs 14:51:34 Integrated Voltage Measurement... 14:51:43 Voltage Offset Correction: v_off_ini = 29.142 uV, v_off_fin = 14.499 uV 14:51:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.002 uVs 14:51:43 Integrated Voltage Measurement... 14:51:52 Voltage Offset Correction: v_off_ini = 38.356 uV, v_off_fin = 38.423 uV 14:51:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.028 uVs 14:51:56 I1Y Average and RMS of Measurements VT = -191.314 +- 3.362 uVs I1Y = -38.263 +- 0.672 uTm 14:52:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:52:04 Integrated Voltage Measurement... 14:52:13 Voltage Offset Correction: v_off_ini = 32.600 uV, v_off_fin = 19.816 uV 14:52:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -66.750 uVs 14:52:13 Integrated Voltage Measurement... 14:52:22 Voltage Offset Correction: v_off_ini = 29.490 uV, v_off_fin = 43.872 uV 14:52:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 71.175 uVs 14:52:22 Integrated Voltage Measurement... 14:52:31 Voltage Offset Correction: v_off_ini = 31.228 uV, v_off_fin = 24.083 uV 14:52:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.223 uVs 14:52:31 Integrated Voltage Measurement... 14:52:40 Voltage Offset Correction: v_off_ini = 24.046 uV, v_off_fin = 35.722 uV 14:52:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 87.838 uVs 14:52:40 Integrated Voltage Measurement... 14:52:49 Voltage Offset Correction: v_off_ini = 32.237 uV, v_off_fin = 28.339 uV 14:52:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.138 uVs 14:52:49 Integrated Voltage Measurement... 14:52:58 Voltage Offset Correction: v_off_ini = 21.191 uV, v_off_fin = 38.773 uV 14:52:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.240 uVs 14:53:00 I2X Average and RMS of Measurements VT = -80.394 +- 8.322 uVs I2X = 7.396 +- 0.766 uTm^2 14:53:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:53:08 Integrated Voltage Measurement... 14:53:17 Voltage Offset Correction: v_off_ini = 40.430 uV, v_off_fin = 35.311 uV 14:53:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.301 uVs 14:53:17 Integrated Voltage Measurement... 14:53:26 Voltage Offset Correction: v_off_ini = 42.018 uV, v_off_fin = 17.300 uV 14:53:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 158.123 uVs 14:53:26 Integrated Voltage Measurement... 14:53:35 Voltage Offset Correction: v_off_ini = 38.562 uV, v_off_fin = 27.448 uV 14:53:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.640 uVs 14:53:35 Integrated Voltage Measurement... 14:53:44 Voltage Offset Correction: v_off_ini = 32.703 uV, v_off_fin = 33.051 uV 14:53:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.885 uVs 14:53:44 Integrated Voltage Measurement... 14:53:53 Voltage Offset Correction: v_off_ini = 42.028 uV, v_off_fin = 35.972 uV 14:53:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.354 uVs 14:53:53 Integrated Voltage Measurement... 14:54:02 Voltage Offset Correction: v_off_ini = 48.005 uV, v_off_fin = 49.008 uV 14:54:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 154.903 uVs 14:54:05 I2Y Average and RMS of Measurements VT = -169.868 +- 3.097 uVs I2Y = -15.628 +- 0.285 uTm^2 14:54:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:54:13 Integrated Voltage Measurement... 14:54:22 Voltage Offset Correction: v_off_ini = 43.116 uV, v_off_fin = 46.526 uV 14:54:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -109.962 uVs 14:54:22 Integrated Voltage Measurement... 14:54:31 Voltage Offset Correction: v_off_ini = 53.210 uV, v_off_fin = 62.988 uV 14:54:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.205 uVs 14:54:31 Integrated Voltage Measurement... 14:54:40 Voltage Offset Correction: v_off_ini = 51.068 uV, v_off_fin = 41.523 uV 14:54:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.136 uVs 14:54:40 Integrated Voltage Measurement... 14:54:49 Voltage Offset Correction: v_off_ini = 50.234 uV, v_off_fin = 58.797 uV 14:54:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.334 uVs 14:54:50 Integrated Voltage Measurement... 14:54:58 Voltage Offset Correction: v_off_ini = 56.084 uV, v_off_fin = 61.940 uV 14:54:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.202 uVs 14:54:59 Integrated Voltage Measurement... 14:55:07 Voltage Offset Correction: v_off_ini = 59.684 uV, v_off_fin = 65.079 uV 14:55:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.469 uVs 14:55:12 I1X Average and RMS of Measurements VT = -96.385 +- 7.928 uVs I1X = 19.278 +- 1.586 uTm 14:55:14 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:55:19 Integrated Voltage Measurement... 14:55:27 Voltage Offset Correction: v_off_ini = 54.517 uV, v_off_fin = 42.021 uV 14:55:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -188.260 uVs 14:55:28 Integrated Voltage Measurement... 14:55:36 Voltage Offset Correction: v_off_ini = 49.499 uV, v_off_fin = 73.580 uV 14:55:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.086 uVs 14:55:37 Integrated Voltage Measurement... 14:55:45 Voltage Offset Correction: v_off_ini = 58.358 uV, v_off_fin = 49.448 uV 14:55:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.106 uVs 14:55:46 Integrated Voltage Measurement... 14:55:54 Voltage Offset Correction: v_off_ini = 41.533 uV, v_off_fin = 61.179 uV 14:55:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.688 uVs 14:55:55 Integrated Voltage Measurement... 14:56:03 Voltage Offset Correction: v_off_ini = 51.350 uV, v_off_fin = 46.180 uV 14:56:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.116 uVs 14:56:04 Integrated Voltage Measurement... 14:56:12 Voltage Offset Correction: v_off_ini = 46.075 uV, v_off_fin = 63.767 uV 14:56:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.601 uVs 14:56:17 I1Y Average and RMS of Measurements VT = -182.643 +- 8.500 uVs I1Y = -36.529 +- 1.700 uTm 14:56:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:56:25 Integrated Voltage Measurement... 14:56:34 Voltage Offset Correction: v_off_ini = 40.042 uV, v_off_fin = 42.332 uV 14:56:34 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -97.758 uVs 14:56:34 Integrated Voltage Measurement... 14:56:43 Voltage Offset Correction: v_off_ini = 51.344 uV, v_off_fin = 62.714 uV 14:56:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 79.913 uVs 14:56:43 Integrated Voltage Measurement... 14:56:52 Voltage Offset Correction: v_off_ini = 67.938 uV, v_off_fin = 48.233 uV 14:56:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.540 uVs 14:56:52 Integrated Voltage Measurement... 14:57:01 Voltage Offset Correction: v_off_ini = 53.815 uV, v_off_fin = 50.613 uV 14:57:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.458 uVs 14:57:01 Integrated Voltage Measurement... 14:57:10 Voltage Offset Correction: v_off_ini = 47.789 uV, v_off_fin = 45.819 uV 14:57:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.124 uVs 14:57:10 Integrated Voltage Measurement... 14:57:19 Voltage Offset Correction: v_off_ini = 46.276 uV, v_off_fin = 48.640 uV 14:57:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.596 uVs 14:57:21 I2X Average and RMS of Measurements VT = -94.065 +- 3.707 uVs I2X = 8.654 +- 0.341 uTm^2 14:57:26 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:57:29 Integrated Voltage Measurement... 14:57:38 Voltage Offset Correction: v_off_ini = 43.615 uV, v_off_fin = 41.389 uV 14:57:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -154.142 uVs 14:57:38 Integrated Voltage Measurement... 14:57:47 Voltage Offset Correction: v_off_ini = 40.051 uV, v_off_fin = 43.706 uV 14:57:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 132.019 uVs 14:57:47 Integrated Voltage Measurement... 14:57:56 Voltage Offset Correction: v_off_ini = 41.106 uV, v_off_fin = 37.393 uV 14:57:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -159.711 uVs 14:57:56 Integrated Voltage Measurement... 14:58:05 Voltage Offset Correction: v_off_ini = 54.677 uV, v_off_fin = 45.093 uV 14:58:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 143.801 uVs 14:58:05 Integrated Voltage Measurement... 14:58:14 Voltage Offset Correction: v_off_ini = 46.504 uV, v_off_fin = 41.122 uV 14:58:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -142.614 uVs 14:58:14 Integrated Voltage Measurement... 14:58:23 Voltage Offset Correction: v_off_ini = 41.370 uV, v_off_fin = 49.511 uV 14:58:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 159.072 uVs 14:58:26 I2Y Average and RMS of Measurements VT = -148.560 +- 3.892 uVs I2Y = -13.667 +- 0.358 uTm^2 14:58:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:58:34 Integrated Voltage Measurement... 14:58:43 Voltage Offset Correction: v_off_ini = 54.015 uV, v_off_fin = 47.189 uV 14:58:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.800 uVs 14:58:43 Integrated Voltage Measurement... 14:58:52 Voltage Offset Correction: v_off_ini = 30.671 uV, v_off_fin = 45.503 uV 14:58:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.357 uVs 14:58:53 Integrated Voltage Measurement... 14:59:01 Voltage Offset Correction: v_off_ini = 36.296 uV, v_off_fin = 39.371 uV 14:59:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -98.819 uVs 14:59:02 Integrated Voltage Measurement... 14:59:10 Voltage Offset Correction: v_off_ini = 55.076 uV, v_off_fin = 50.096 uV 14:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.386 uVs 14:59:11 Integrated Voltage Measurement... 14:59:20 Voltage Offset Correction: v_off_ini = 59.202 uV, v_off_fin = 58.500 uV 14:59:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.872 uVs 14:59:20 Integrated Voltage Measurement... 14:59:29 Voltage Offset Correction: v_off_ini = 48.896 uV, v_off_fin = 59.174 uV 14:59:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.953 uVs 14:59:33 I1X Average and RMS of Measurements VT = -103.531 +- 11.435 uVs I1X = 20.707 +- 2.286 uTm 14:59:35 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:59:40 Integrated Voltage Measurement... 14:59:49 Voltage Offset Correction: v_off_ini = 65.239 uV, v_off_fin = 55.033 uV 14:59:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.447 uVs 14:59:49 Integrated Voltage Measurement... 14:59:58 Voltage Offset Correction: v_off_ini = 47.584 uV, v_off_fin = 79.448 uV 14:59:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.840 uVs 14:59:58 Integrated Voltage Measurement... 15:00:07 Voltage Offset Correction: v_off_ini = 77.927 uV, v_off_fin = 68.456 uV 15:00:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.638 uVs 15:00:07 Integrated Voltage Measurement... 15:00:16 Voltage Offset Correction: v_off_ini = 74.870 uV, v_off_fin = 71.618 uV 15:00:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 145.650 uVs 15:00:16 Integrated Voltage Measurement... 15:00:25 Voltage Offset Correction: v_off_ini = 77.930 uV, v_off_fin = 71.921 uV 15:00:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -165.790 uVs 15:00:25 Integrated Voltage Measurement... 15:00:34 Voltage Offset Correction: v_off_ini = 72.983 uV, v_off_fin = 80.652 uV 15:00:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 151.495 uVs 15:00:38 I1Y Average and RMS of Measurements VT = -169.310 +- 13.695 uVs I1Y = -33.862 +- 2.739 uTm 15:00:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:00:46 Integrated Voltage Measurement... 15:00:54 Voltage Offset Correction: v_off_ini = 73.676 uV, v_off_fin = 56.073 uV 15:00:55 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -89.506 uVs 15:00:55 Integrated Voltage Measurement... 15:01:04 Voltage Offset Correction: v_off_ini = 72.271 uV, v_off_fin = 69.790 uV 15:01:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.616 uVs 15:01:04 Integrated Voltage Measurement... 15:01:13 Voltage Offset Correction: v_off_ini = 65.718 uV, v_off_fin = 71.526 uV 15:01:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -101.661 uVs 15:01:13 Integrated Voltage Measurement... 15:01:22 Voltage Offset Correction: v_off_ini = 83.066 uV, v_off_fin = 82.971 uV 15:01:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 99.756 uVs 15:01:22 Integrated Voltage Measurement... 15:01:31 Voltage Offset Correction: v_off_ini = 80.625 uV, v_off_fin = 63.783 uV 15:01:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.931 uVs 15:01:31 Integrated Voltage Measurement... 15:01:40 Voltage Offset Correction: v_off_ini = 62.792 uV, v_off_fin = 65.590 uV 15:01:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.209 uVs 15:01:42 I2X Average and RMS of Measurements VT = -97.613 +- 2.995 uVs I2X = 8.980 +- 0.276 uTm^2 15:01:47 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:01:50 Integrated Voltage Measurement... 15:01:59 Voltage Offset Correction: v_off_ini = 47.004 uV, v_off_fin = 61.642 uV 15:01:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -157.305 uVs 15:01:59 Integrated Voltage Measurement... 15:02:08 Voltage Offset Correction: v_off_ini = 36.665 uV, v_off_fin = 54.070 uV 15:02:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 148.406 uVs 15:02:08 Integrated Voltage Measurement... 15:02:17 Voltage Offset Correction: v_off_ini = 60.809 uV, v_off_fin = 60.534 uV 15:02:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -158.252 uVs 15:02:17 Integrated Voltage Measurement... 15:02:26 Voltage Offset Correction: v_off_ini = 65.855 uV, v_off_fin = 63.149 uV 15:02:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 121.829 uVs 15:02:26 Integrated Voltage Measurement... 15:02:35 Voltage Offset Correction: v_off_ini = 65.001 uV, v_off_fin = 67.246 uV 15:02:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -150.891 uVs 15:02:35 Integrated Voltage Measurement... 15:02:44 Voltage Offset Correction: v_off_ini = 58.390 uV, v_off_fin = 57.807 uV 15:02:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 141.420 uVs 15:02:46 I2Y Average and RMS of Measurements VT = -146.351 +- 5.233 uVs I2Y = -13.464 +- 0.481 uTm^2 15:02:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:02:58 Integrated Voltage Measurement... 15:03:07 Voltage Offset Correction: v_off_ini = 66.167 uV, v_off_fin = 61.108 uV 15:03:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.130 uVs 15:03:07 Integrated Voltage Measurement... 15:03:16 Voltage Offset Correction: v_off_ini = 58.414 uV, v_off_fin = 62.007 uV 15:03:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.767 uVs 15:03:16 Integrated Voltage Measurement... 15:03:25 Voltage Offset Correction: v_off_ini = 55.379 uV, v_off_fin = 58.906 uV 15:03:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.725 uVs 15:03:25 Integrated Voltage Measurement... 15:03:34 Voltage Offset Correction: v_off_ini = 60.652 uV, v_off_fin = 65.385 uV 15:03:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.400 uVs 15:03:34 Integrated Voltage Measurement... 15:03:43 Voltage Offset Correction: v_off_ini = 51.892 uV, v_off_fin = 62.356 uV 15:03:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.457 uVs 15:03:43 Integrated Voltage Measurement... 15:03:52 Voltage Offset Correction: v_off_ini = 61.325 uV, v_off_fin = 53.108 uV 15:03:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.111 uVs 15:03:57 I1X Average and RMS of Measurements VT = -65.598 +- 6.489 uVs I1X = 13.120 +- 1.298 uTm 15:03:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:04:03 Integrated Voltage Measurement... 15:04:12 Voltage Offset Correction: v_off_ini = 32.494 uV, v_off_fin = 34.427 uV 15:04:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.808 uVs 15:04:13 Integrated Voltage Measurement... 15:04:21 Voltage Offset Correction: v_off_ini = 53.817 uV, v_off_fin = 56.670 uV 15:04:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.379 uVs 15:04:22 Integrated Voltage Measurement... 15:04:30 Voltage Offset Correction: v_off_ini = 49.579 uV, v_off_fin = 33.726 uV 15:04:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.852 uVs 15:04:30 Integrated Voltage Measurement... 15:04:39 Voltage Offset Correction: v_off_ini = 50.559 uV, v_off_fin = 44.962 uV 15:04:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.443 uVs 15:04:40 Integrated Voltage Measurement... 15:04:48 Voltage Offset Correction: v_off_ini = 25.343 uV, v_off_fin = 28.210 uV 15:04:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -166.288 uVs 15:04:49 Integrated Voltage Measurement... 15:04:57 Voltage Offset Correction: v_off_ini = 36.044 uV, v_off_fin = 43.707 uV 15:04:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.905 uVs 15:05:02 I1Y Average and RMS of Measurements VT = -183.612 +- 7.624 uVs I1Y = -36.722 +- 1.525 uTm 15:05:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:05:07 Integrated Voltage Measurement... 15:05:16 Voltage Offset Correction: v_off_ini = 37.232 uV, v_off_fin = 31.687 uV 15:05:16 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -71.279 uVs 15:05:16 Integrated Voltage Measurement... 15:05:25 Voltage Offset Correction: v_off_ini = 38.324 uV, v_off_fin = 43.262 uV 15:05:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.737 uVs 15:05:25 Integrated Voltage Measurement... 15:05:34 Voltage Offset Correction: v_off_ini = 45.550 uV, v_off_fin = 26.403 uV 15:05:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.113 uVs 15:05:34 Integrated Voltage Measurement... 15:05:43 Voltage Offset Correction: v_off_ini = 39.003 uV, v_off_fin = 41.157 uV 15:05:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.924 uVs 15:05:43 Integrated Voltage Measurement... 15:05:52 Voltage Offset Correction: v_off_ini = 18.813 uV, v_off_fin = 0.706 uV 15:05:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.909 uVs 15:05:52 Integrated Voltage Measurement... 15:06:01 Voltage Offset Correction: v_off_ini = 10.871 uV, v_off_fin = 12.199 uV 15:06:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.483 uVs 15:06:03 I2X Average and RMS of Measurements VT = -61.241 +- 10.293 uVs I2X = 5.634 +- 0.947 uTm^2 15:06:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:06:09 Integrated Voltage Measurement... 15:06:18 Voltage Offset Correction: v_off_ini = 22.201 uV, v_off_fin = 7.507 uV 15:06:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -154.553 uVs 15:06:18 Integrated Voltage Measurement... 15:06:27 Voltage Offset Correction: v_off_ini = 21.029 uV, v_off_fin = 9.102 uV 15:06:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.090 uVs 15:06:27 Integrated Voltage Measurement... 15:06:36 Voltage Offset Correction: v_off_ini = 0.453 uV, v_off_fin = -4.234 uV 15:06:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.204 uVs 15:06:36 Integrated Voltage Measurement... 15:06:45 Voltage Offset Correction: v_off_ini = 0.870 uV, v_off_fin = 18.490 uV 15:06:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.697 uVs 15:06:45 Integrated Voltage Measurement... 15:06:54 Voltage Offset Correction: v_off_ini = 21.562 uV, v_off_fin = 25.514 uV 15:06:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -150.189 uVs 15:06:54 Integrated Voltage Measurement... 15:07:03 Voltage Offset Correction: v_off_ini = 33.458 uV, v_off_fin = 28.413 uV 15:07:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.096 uVs 15:07:05 I2Y Average and RMS of Measurements VT = -160.638 +- 5.164 uVs I2Y = -14.779 +- 0.475 uTm^2 15:07:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:07:14 Integrated Voltage Measurement... 15:07:22 Voltage Offset Correction: v_off_ini = 20.302 uV, v_off_fin = 9.685 uV 15:07:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.307 uVs 15:07:23 Integrated Voltage Measurement... 15:07:32 Voltage Offset Correction: v_off_ini = 15.006 uV, v_off_fin = 34.179 uV 15:07:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.985 uVs 15:07:32 Integrated Voltage Measurement... 15:07:41 Voltage Offset Correction: v_off_ini = 33.439 uV, v_off_fin = 21.340 uV 15:07:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.024 uVs 15:07:41 Integrated Voltage Measurement... 15:07:50 Voltage Offset Correction: v_off_ini = 11.533 uV, v_off_fin = 31.461 uV 15:07:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.898 uVs 15:07:50 Integrated Voltage Measurement... 15:07:59 Voltage Offset Correction: v_off_ini = 26.868 uV, v_off_fin = 24.145 uV 15:07:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.160 uVs 15:07:59 Integrated Voltage Measurement... 15:08:08 Voltage Offset Correction: v_off_ini = 35.793 uV, v_off_fin = 41.012 uV 15:08:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.009 uVs 15:08:12 I1X Average and RMS of Measurements VT = -80.897 +- 10.001 uVs I1X = 16.180 +- 2.000 uTm 15:08:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:08:19 Integrated Voltage Measurement... 15:08:28 Voltage Offset Correction: v_off_ini = 35.735 uV, v_off_fin = 15.126 uV 15:08:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.748 uVs 15:08:28 Integrated Voltage Measurement... 15:08:37 Voltage Offset Correction: v_off_ini = 40.629 uV, v_off_fin = 53.731 uV 15:08:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.127 uVs 15:08:37 Integrated Voltage Measurement... 15:08:46 Voltage Offset Correction: v_off_ini = 38.236 uV, v_off_fin = 13.159 uV 15:08:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.567 uVs 15:08:46 Integrated Voltage Measurement... 15:08:55 Voltage Offset Correction: v_off_ini = 32.693 uV, v_off_fin = 39.986 uV 15:08:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.719 uVs 15:08:55 Integrated Voltage Measurement... 15:09:04 Voltage Offset Correction: v_off_ini = 27.707 uV, v_off_fin = 18.898 uV 15:09:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.076 uVs 15:09:04 Integrated Voltage Measurement... 15:09:13 Voltage Offset Correction: v_off_ini = 39.134 uV, v_off_fin = 55.021 uV 15:09:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.664 uVs 15:09:17 I1Y Average and RMS of Measurements VT = -192.150 +- 11.169 uVs I1Y = -38.430 +- 2.234 uTm 15:09:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:09:22 Integrated Voltage Measurement... 15:09:31 Voltage Offset Correction: v_off_ini = 52.251 uV, v_off_fin = 40.236 uV 15:09:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.796 uVs 15:09:31 Integrated Voltage Measurement... 15:09:40 Voltage Offset Correction: v_off_ini = 52.237 uV, v_off_fin = 62.934 uV 15:09:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.026 uVs 15:09:40 Integrated Voltage Measurement... 15:09:49 Voltage Offset Correction: v_off_ini = 43.709 uV, v_off_fin = 31.761 uV 15:09:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.053 uVs 15:09:49 Integrated Voltage Measurement... 15:09:58 Voltage Offset Correction: v_off_ini = 29.679 uV, v_off_fin = 42.859 uV 15:09:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.719 uVs 15:09:58 Integrated Voltage Measurement... 15:10:07 Voltage Offset Correction: v_off_ini = 32.062 uV, v_off_fin = 27.393 uV 15:10:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -66.998 uVs 15:10:07 Integrated Voltage Measurement... 15:10:16 Voltage Offset Correction: v_off_ini = 36.715 uV, v_off_fin = 37.627 uV 15:10:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 72.177 uVs 15:10:19 I2X Average and RMS of Measurements VT = -62.628 +- 4.926 uVs I2X = 5.762 +- 0.453 uTm^2 15:10:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:10:24 Integrated Voltage Measurement... 15:10:33 Voltage Offset Correction: v_off_ini = 41.799 uV, v_off_fin = 31.296 uV 15:10:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.309 uVs 15:10:33 Integrated Voltage Measurement... 15:10:42 Voltage Offset Correction: v_off_ini = 35.373 uV, v_off_fin = 34.668 uV 15:10:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 165.160 uVs 15:10:42 Integrated Voltage Measurement... 15:10:51 Voltage Offset Correction: v_off_ini = 21.403 uV, v_off_fin = 21.641 uV 15:10:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -154.265 uVs 15:10:51 Integrated Voltage Measurement... 15:11:00 Voltage Offset Correction: v_off_ini = 43.770 uV, v_off_fin = 49.460 uV 15:11:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 152.129 uVs 15:11:00 Integrated Voltage Measurement... 15:11:09 Voltage Offset Correction: v_off_ini = 27.579 uV, v_off_fin = 41.102 uV 15:11:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -158.424 uVs 15:11:09 Integrated Voltage Measurement... 15:11:18 Voltage Offset Correction: v_off_ini = 48.252 uV, v_off_fin = 53.172 uV 15:11:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 149.625 uVs 15:11:20 I2Y Average and RMS of Measurements VT = -156.985 +- 4.784 uVs I2Y = -14.443 +- 0.440 uTm^2 15:11:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:11:29 Integrated Voltage Measurement... 15:11:38 Voltage Offset Correction: v_off_ini = 49.074 uV, v_off_fin = 39.549 uV 15:11:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.478 uVs 15:11:38 Integrated Voltage Measurement... 15:11:47 Voltage Offset Correction: v_off_ini = 51.963 uV, v_off_fin = 50.218 uV 15:11:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.900 uVs 15:11:47 Integrated Voltage Measurement... 15:11:56 Voltage Offset Correction: v_off_ini = 42.590 uV, v_off_fin = 39.172 uV 15:11:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.988 uVs 15:11:56 Integrated Voltage Measurement... 15:12:05 Voltage Offset Correction: v_off_ini = 57.931 uV, v_off_fin = 64.986 uV 15:12:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.615 uVs 15:12:05 Integrated Voltage Measurement... 15:12:14 Voltage Offset Correction: v_off_ini = 52.865 uV, v_off_fin = 47.980 uV 15:12:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -115.115 uVs 15:12:14 Integrated Voltage Measurement... 15:12:23 Voltage Offset Correction: v_off_ini = 52.425 uV, v_off_fin = 61.527 uV 15:12:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 93.818 uVs 15:12:27 I1X Average and RMS of Measurements VT = -103.652 +- 3.674 uVs I1X = 20.732 +- 0.735 uTm 15:12:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:12:34 Integrated Voltage Measurement... 15:12:43 Voltage Offset Correction: v_off_ini = 68.416 uV, v_off_fin = 57.957 uV 15:12:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.602 uVs 15:12:43 Integrated Voltage Measurement... 15:12:52 Voltage Offset Correction: v_off_ini = 63.569 uV, v_off_fin = 54.538 uV 15:12:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.970 uVs 15:12:52 Integrated Voltage Measurement... 15:13:01 Voltage Offset Correction: v_off_ini = 56.277 uV, v_off_fin = 42.072 uV 15:13:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.022 uVs 15:13:01 Integrated Voltage Measurement... 15:13:10 Voltage Offset Correction: v_off_ini = 52.848 uV, v_off_fin = 60.930 uV 15:13:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.863 uVs 15:13:10 Integrated Voltage Measurement... 15:13:19 Voltage Offset Correction: v_off_ini = 69.152 uV, v_off_fin = 41.132 uV 15:13:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.490 uVs 15:13:19 Integrated Voltage Measurement... 15:13:28 Voltage Offset Correction: v_off_ini = 58.373 uV, v_off_fin = 60.651 uV 15:13:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.597 uVs 15:13:32 I1Y Average and RMS of Measurements VT = -198.091 +- 3.169 uVs I1Y = -39.618 +- 0.634 uTm 15:13:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:13:37 Integrated Voltage Measurement... 15:13:46 Voltage Offset Correction: v_off_ini = 31.510 uV, v_off_fin = 33.124 uV 15:13:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -79.300 uVs 15:13:46 Integrated Voltage Measurement... 15:13:55 Voltage Offset Correction: v_off_ini = 25.116 uV, v_off_fin = 47.317 uV 15:13:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.154 uVs 15:13:55 Integrated Voltage Measurement... 15:14:04 Voltage Offset Correction: v_off_ini = 32.830 uV, v_off_fin = 25.130 uV 15:14:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.940 uVs 15:14:04 Integrated Voltage Measurement... 15:14:13 Voltage Offset Correction: v_off_ini = 40.992 uV, v_off_fin = 37.608 uV 15:14:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.751 uVs 15:14:13 Integrated Voltage Measurement... 15:14:22 Voltage Offset Correction: v_off_ini = 38.439 uV, v_off_fin = 3.724 uV 15:14:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.370 uVs 15:14:22 Integrated Voltage Measurement... 15:14:31 Voltage Offset Correction: v_off_ini = 20.230 uV, v_off_fin = 31.576 uV 15:14:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 86.503 uVs 15:14:34 I2X Average and RMS of Measurements VT = -84.837 +- 2.299 uVs I2X = 7.805 +- 0.212 uTm^2 15:14:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:14:39 Integrated Voltage Measurement... 15:14:48 Voltage Offset Correction: v_off_ini = 45.056 uV, v_off_fin = 34.815 uV 15:14:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.883 uVs 15:14:48 Integrated Voltage Measurement... 15:14:57 Voltage Offset Correction: v_off_ini = 37.198 uV, v_off_fin = 41.836 uV 15:14:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 160.921 uVs 15:14:57 Integrated Voltage Measurement... 15:15:06 Voltage Offset Correction: v_off_ini = 49.699 uV, v_off_fin = 36.741 uV 15:15:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -160.164 uVs 15:15:06 Integrated Voltage Measurement... 15:15:15 Voltage Offset Correction: v_off_ini = 24.572 uV, v_off_fin = 39.664 uV 15:15:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.879 uVs 15:15:15 Integrated Voltage Measurement... 15:15:24 Voltage Offset Correction: v_off_ini = 36.816 uV, v_off_fin = 44.584 uV 15:15:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -167.060 uVs 15:15:24 Integrated Voltage Measurement... 15:15:33 Voltage Offset Correction: v_off_ini = 44.740 uV, v_off_fin = 40.731 uV 15:15:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 140.755 uVs 15:15:35 I2Y Average and RMS of Measurements VT = -167.777 +- 10.723 uVs I2Y = -15.435 +- 0.986 uTm^2 15:15:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:15:44 Integrated Voltage Measurement... 15:15:53 Voltage Offset Correction: v_off_ini = 45.733 uV, v_off_fin = 34.866 uV 15:15:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -114.595 uVs 15:15:53 Integrated Voltage Measurement... 15:16:02 Voltage Offset Correction: v_off_ini = 44.174 uV, v_off_fin = 34.713 uV 15:16:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.518 uVs 15:16:02 Integrated Voltage Measurement... 15:16:11 Voltage Offset Correction: v_off_ini = 37.176 uV, v_off_fin = 25.829 uV 15:16:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -115.278 uVs 15:16:11 Integrated Voltage Measurement... 15:16:20 Voltage Offset Correction: v_off_ini = 33.653 uV, v_off_fin = 35.744 uV 15:16:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.164 uVs 15:16:20 Integrated Voltage Measurement... 15:16:29 Voltage Offset Correction: v_off_ini = 36.925 uV, v_off_fin = 35.299 uV 15:16:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.587 uVs 15:16:29 Integrated Voltage Measurement... 15:16:38 Voltage Offset Correction: v_off_ini = 42.042 uV, v_off_fin = 34.123 uV 15:16:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.701 uVs 15:16:42 I1X Average and RMS of Measurements VT = -112.807 +- 2.476 uVs I1X = 22.562 +- 0.495 uTm 15:16:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:16:49 Integrated Voltage Measurement... 15:16:58 Voltage Offset Correction: v_off_ini = 64.478 uV, v_off_fin = 59.442 uV 15:16:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.809 uVs 15:16:58 Integrated Voltage Measurement... 15:17:07 Voltage Offset Correction: v_off_ini = 51.323 uV, v_off_fin = 74.722 uV 15:17:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.744 uVs 15:17:07 Integrated Voltage Measurement... 15:17:15 Voltage Offset Correction: v_off_ini = 70.617 uV, v_off_fin = 57.729 uV 15:17:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -184.386 uVs 15:17:16 Integrated Voltage Measurement... 15:17:24 Voltage Offset Correction: v_off_ini = 61.935 uV, v_off_fin = 76.737 uV 15:17:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.264 uVs 15:17:25 Integrated Voltage Measurement... 15:17:33 Voltage Offset Correction: v_off_ini = 67.054 uV, v_off_fin = 44.544 uV 15:17:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.590 uVs 15:17:34 Integrated Voltage Measurement... 15:17:42 Voltage Offset Correction: v_off_ini = 55.693 uV, v_off_fin = 64.865 uV 15:17:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 192.156 uVs 15:17:47 I1Y Average and RMS of Measurements VT = -193.825 +- 4.049 uVs I1Y = -38.763 +- 0.809 uTm 15:17:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:17:52 Integrated Voltage Measurement... 15:18:01 Voltage Offset Correction: v_off_ini = 52.857 uV, v_off_fin = 61.234 uV 15:18:01 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -92.997 uVs 15:18:01 Integrated Voltage Measurement... 15:18:10 Voltage Offset Correction: v_off_ini = 48.301 uV, v_off_fin = 52.600 uV 15:18:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.731 uVs 15:18:10 Integrated Voltage Measurement... 15:18:19 Voltage Offset Correction: v_off_ini = 39.703 uV, v_off_fin = 44.530 uV 15:18:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.768 uVs 15:18:19 Integrated Voltage Measurement... 15:18:28 Voltage Offset Correction: v_off_ini = 59.028 uV, v_off_fin = 66.325 uV 15:18:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.258 uVs 15:18:28 Integrated Voltage Measurement... 15:18:37 Voltage Offset Correction: v_off_ini = 45.917 uV, v_off_fin = 32.053 uV 15:18:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.183 uVs 15:18:37 Integrated Voltage Measurement... 15:18:46 Voltage Offset Correction: v_off_ini = 38.696 uV, v_off_fin = 52.280 uV 15:18:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.829 uVs 15:18:48 I2X Average and RMS of Measurements VT = -87.628 +- 8.847 uVs I2X = 8.062 +- 0.814 uTm^2 15:18:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:18:53 Integrated Voltage Measurement... 15:19:02 Voltage Offset Correction: v_off_ini = 49.747 uV, v_off_fin = 49.205 uV 15:19:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -164.560 uVs 15:19:02 Integrated Voltage Measurement... 15:19:11 Voltage Offset Correction: v_off_ini = 54.220 uV, v_off_fin = 48.893 uV 15:19:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 162.651 uVs 15:19:11 Integrated Voltage Measurement... 15:19:20 Voltage Offset Correction: v_off_ini = 54.780 uV, v_off_fin = 35.864 uV 15:19:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.351 uVs 15:19:20 Integrated Voltage Measurement... 15:19:29 Voltage Offset Correction: v_off_ini = 27.424 uV, v_off_fin = 36.071 uV 15:19:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 168.843 uVs 15:19:29 Integrated Voltage Measurement... 15:19:38 Voltage Offset Correction: v_off_ini = 25.259 uV, v_off_fin = 41.186 uV 15:19:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.812 uVs 15:19:38 Integrated Voltage Measurement... 15:19:47 Voltage Offset Correction: v_off_ini = 44.307 uV, v_off_fin = 46.154 uV 15:19:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 146.828 uVs 15:19:50 I2Y Average and RMS of Measurements VT = -164.341 +- 7.683 uVs I2Y = -15.119 +- 0.707 uTm^2 15:19:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:19:58 Integrated Voltage Measurement... 15:20:07 Voltage Offset Correction: v_off_ini = 54.282 uV, v_off_fin = 49.904 uV 15:20:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.904 uVs 15:20:07 Integrated Voltage Measurement... 15:20:16 Voltage Offset Correction: v_off_ini = 40.450 uV, v_off_fin = 46.376 uV 15:20:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.706 uVs 15:20:16 Integrated Voltage Measurement... 15:20:25 Voltage Offset Correction: v_off_ini = 60.906 uV, v_off_fin = 50.888 uV 15:20:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.404 uVs 15:20:25 Integrated Voltage Measurement... 15:20:34 Voltage Offset Correction: v_off_ini = 49.899 uV, v_off_fin = 64.157 uV 15:20:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.371 uVs 15:20:34 Integrated Voltage Measurement... 15:20:43 Voltage Offset Correction: v_off_ini = 63.023 uV, v_off_fin = 54.365 uV 15:20:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.646 uVs 15:20:43 Integrated Voltage Measurement... 15:20:52 Voltage Offset Correction: v_off_ini = 68.605 uV, v_off_fin = 52.584 uV 15:20:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.704 uVs 15:20:56 I1X Average and RMS of Measurements VT = -96.622 +- 14.208 uVs I1X = 19.325 +- 2.842 uTm 15:20:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:21:03 Integrated Voltage Measurement... 15:21:12 Voltage Offset Correction: v_off_ini = 46.075 uV, v_off_fin = 28.837 uV 15:21:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -189.035 uVs 15:21:12 Integrated Voltage Measurement... 15:21:21 Voltage Offset Correction: v_off_ini = 37.914 uV, v_off_fin = 42.852 uV 15:21:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.306 uVs 15:21:21 Integrated Voltage Measurement... 15:21:30 Voltage Offset Correction: v_off_ini = 26.821 uV, v_off_fin = 20.928 uV 15:21:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.241 uVs 15:21:30 Integrated Voltage Measurement... 15:21:39 Voltage Offset Correction: v_off_ini = 40.452 uV, v_off_fin = 55.006 uV 15:21:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.779 uVs 15:21:39 Integrated Voltage Measurement... 15:21:48 Voltage Offset Correction: v_off_ini = 53.813 uV, v_off_fin = 39.252 uV 15:21:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.228 uVs 15:21:48 Integrated Voltage Measurement... 15:21:57 Voltage Offset Correction: v_off_ini = 51.566 uV, v_off_fin = 56.067 uV 15:21:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.486 uVs 15:22:01 I1Y Average and RMS of Measurements VT = -188.846 +- 9.077 uVs I1Y = -37.768 +- 1.814 uTm 15:22:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:22:06 Integrated Voltage Measurement... 15:22:15 Voltage Offset Correction: v_off_ini = 42.910 uV, v_off_fin = 30.554 uV 15:22:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.482 uVs 15:22:15 Integrated Voltage Measurement... 15:22:24 Voltage Offset Correction: v_off_ini = 34.076 uV, v_off_fin = 43.171 uV 15:22:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.268 uVs 15:22:24 Integrated Voltage Measurement... 15:22:33 Voltage Offset Correction: v_off_ini = 22.247 uV, v_off_fin = 31.411 uV 15:22:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.128 uVs 15:22:33 Integrated Voltage Measurement... 15:22:42 Voltage Offset Correction: v_off_ini = 37.260 uV, v_off_fin = 47.644 uV 15:22:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 77.427 uVs 15:22:42 Integrated Voltage Measurement... 15:22:51 Voltage Offset Correction: v_off_ini = 37.124 uV, v_off_fin = 32.394 uV 15:22:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.336 uVs 15:22:51 Integrated Voltage Measurement... 15:23:00 Voltage Offset Correction: v_off_ini = 38.296 uV, v_off_fin = 64.818 uV 15:23:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.611 uVs 15:23:03 I2X Average and RMS of Measurements VT = -83.875 +- 6.605 uVs I2X = 7.717 +- 0.608 uTm^2 15:23:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:23:08 Integrated Voltage Measurement... 15:23:17 Voltage Offset Correction: v_off_ini = 44.146 uV, v_off_fin = 44.288 uV 15:23:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.358 uVs 15:23:17 Integrated Voltage Measurement... 15:23:26 Voltage Offset Correction: v_off_ini = 51.753 uV, v_off_fin = 58.112 uV 15:23:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.330 uVs 15:23:26 Integrated Voltage Measurement... 15:23:35 Voltage Offset Correction: v_off_ini = 51.448 uV, v_off_fin = 48.704 uV 15:23:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.117 uVs 15:23:35 Integrated Voltage Measurement... 15:23:44 Voltage Offset Correction: v_off_ini = 34.635 uV, v_off_fin = 35.131 uV 15:23:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.229 uVs 15:23:44 Integrated Voltage Measurement... 15:23:53 Voltage Offset Correction: v_off_ini = 46.633 uV, v_off_fin = 50.306 uV 15:23:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.308 uVs 15:23:53 Integrated Voltage Measurement... 15:24:02 Voltage Offset Correction: v_off_ini = 44.072 uV, v_off_fin = 44.480 uV 15:24:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 157.065 uVs 15:24:04 I2Y Average and RMS of Measurements VT = -172.568 +- 10.785 uVs I2Y = -15.876 +- 0.992 uTm^2 15:24:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:24:26 Integrated Voltage Measurement... 15:24:35 Voltage Offset Correction: v_off_ini = 41.009 uV, v_off_fin = 54.526 uV 15:24:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.059 uVs 15:24:35 Integrated Voltage Measurement... 15:24:44 Voltage Offset Correction: v_off_ini = 56.025 uV, v_off_fin = 70.956 uV 15:24:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.993 uVs 15:24:44 Integrated Voltage Measurement... 15:24:53 Voltage Offset Correction: v_off_ini = 61.704 uV, v_off_fin = 51.062 uV 15:24:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.663 uVs 15:24:53 Integrated Voltage Measurement... 15:25:02 Voltage Offset Correction: v_off_ini = 52.731 uV, v_off_fin = 62.358 uV 15:25:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.169 uVs 15:25:02 Integrated Voltage Measurement... 15:25:11 Voltage Offset Correction: v_off_ini = 57.013 uV, v_off_fin = 57.455 uV 15:25:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.340 uVs 15:25:11 Integrated Voltage Measurement... 15:25:20 Voltage Offset Correction: v_off_ini = 48.885 uV, v_off_fin = 59.619 uV 15:25:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.479 uVs 15:25:24 I1X Average and RMS of Measurements VT = -79.950 +- 2.453 uVs I1X = 15.990 +- 0.491 uTm 15:25:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:25:31 Integrated Voltage Measurement... 15:25:40 Voltage Offset Correction: v_off_ini = 63.722 uV, v_off_fin = 44.178 uV 15:25:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.155 uVs 15:25:40 Integrated Voltage Measurement... 15:25:49 Voltage Offset Correction: v_off_ini = 45.164 uV, v_off_fin = 60.874 uV 15:25:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.471 uVs 15:25:49 Integrated Voltage Measurement... 15:25:58 Voltage Offset Correction: v_off_ini = 51.042 uV, v_off_fin = 52.603 uV 15:25:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.706 uVs 15:25:58 Integrated Voltage Measurement... 15:26:07 Voltage Offset Correction: v_off_ini = 50.872 uV, v_off_fin = 57.034 uV 15:26:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.394 uVs 15:26:07 Integrated Voltage Measurement... 15:26:16 Voltage Offset Correction: v_off_ini = 43.978 uV, v_off_fin = 44.844 uV 15:26:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.755 uVs 15:26:16 Integrated Voltage Measurement... 15:26:25 Voltage Offset Correction: v_off_ini = 31.773 uV, v_off_fin = 61.245 uV 15:26:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.236 uVs 15:26:29 I1Y Average and RMS of Measurements VT = -258.120 +- 8.080 uVs I1Y = -51.624 +- 1.616 uTm 15:26:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:26:36 Integrated Voltage Measurement... 15:26:45 Voltage Offset Correction: v_off_ini = 52.371 uV, v_off_fin = 47.950 uV 15:26:45 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -61.852 uVs 15:26:46 Integrated Voltage Measurement... 15:26:54 Voltage Offset Correction: v_off_ini = 53.895 uV, v_off_fin = 61.742 uV 15:26:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.788 uVs 15:26:55 Integrated Voltage Measurement... 15:27:04 Voltage Offset Correction: v_off_ini = 43.532 uV, v_off_fin = 36.034 uV 15:27:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.886 uVs 15:27:04 Integrated Voltage Measurement... 15:27:13 Voltage Offset Correction: v_off_ini = 42.397 uV, v_off_fin = 53.825 uV 15:27:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.808 uVs 15:27:13 Integrated Voltage Measurement... 15:27:22 Voltage Offset Correction: v_off_ini = 65.492 uV, v_off_fin = 48.327 uV 15:27:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.458 uVs 15:27:22 Integrated Voltage Measurement... 15:27:31 Voltage Offset Correction: v_off_ini = 61.968 uV, v_off_fin = 68.155 uV 15:27:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.627 uVs 15:27:33 I2X Average and RMS of Measurements VT = -48.403 +- 4.341 uVs I2X = 4.453 +- 0.399 uTm^2 15:27:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:27:41 Integrated Voltage Measurement... 15:27:50 Voltage Offset Correction: v_off_ini = 69.480 uV, v_off_fin = 72.477 uV 15:27:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.230 uVs 15:27:50 Integrated Voltage Measurement... 15:27:59 Voltage Offset Correction: v_off_ini = 71.797 uV, v_off_fin = 68.789 uV 15:27:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.736 uVs 15:27:59 Integrated Voltage Measurement... 15:28:08 Voltage Offset Correction: v_off_ini = 72.239 uV, v_off_fin = 59.834 uV 15:28:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.699 uVs 15:28:08 Integrated Voltage Measurement... 15:28:17 Voltage Offset Correction: v_off_ini = 70.336 uV, v_off_fin = 70.563 uV 15:28:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.537 uVs 15:28:17 Integrated Voltage Measurement... 15:28:26 Voltage Offset Correction: v_off_ini = 78.260 uV, v_off_fin = 78.711 uV 15:28:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.936 uVs 15:28:26 Integrated Voltage Measurement... 15:28:35 Voltage Offset Correction: v_off_ini = 67.054 uV, v_off_fin = 68.056 uV 15:28:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.937 uVs 15:28:37 I2Y Average and RMS of Measurements VT = -233.012 +- 8.710 uVs I2Y = -21.437 +- 0.801 uTm^2 15:28:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:28:46 Integrated Voltage Measurement... 15:28:55 Voltage Offset Correction: v_off_ini = 78.866 uV, v_off_fin = 72.571 uV 15:28:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.480 uVs 15:28:55 Integrated Voltage Measurement... 15:29:04 Voltage Offset Correction: v_off_ini = 92.181 uV, v_off_fin = 75.375 uV 15:29:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.994 uVs 15:29:04 Integrated Voltage Measurement... 15:29:13 Voltage Offset Correction: v_off_ini = 63.041 uV, v_off_fin = 49.301 uV 15:29:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.611 uVs 15:29:13 Integrated Voltage Measurement... 15:29:22 Voltage Offset Correction: v_off_ini = 66.375 uV, v_off_fin = 86.872 uV 15:29:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.919 uVs 15:29:22 Integrated Voltage Measurement... 15:29:31 Voltage Offset Correction: v_off_ini = 68.867 uV, v_off_fin = 53.859 uV 15:29:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.043 uVs 15:29:31 Integrated Voltage Measurement... 15:29:40 Voltage Offset Correction: v_off_ini = 65.288 uV, v_off_fin = 60.028 uV 15:29:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.002 uVs 15:29:44 I1X Average and RMS of Measurements VT = -74.008 +- 2.195 uVs I1X = 14.802 +- 0.439 uTm 15:29:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:29:51 Integrated Voltage Measurement... 15:30:00 Voltage Offset Correction: v_off_ini = 50.451 uV, v_off_fin = 58.256 uV 15:30:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.825 uVs 15:30:00 Integrated Voltage Measurement... 15:30:09 Voltage Offset Correction: v_off_ini = 58.449 uV, v_off_fin = 73.747 uV 15:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.042 uVs 15:30:09 Integrated Voltage Measurement... 15:30:18 Voltage Offset Correction: v_off_ini = 67.940 uV, v_off_fin = 58.017 uV 15:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.880 uVs 15:30:18 Integrated Voltage Measurement... 15:30:27 Voltage Offset Correction: v_off_ini = 49.247 uV, v_off_fin = 64.400 uV 15:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.153 uVs 15:30:27 Integrated Voltage Measurement... 15:30:36 Voltage Offset Correction: v_off_ini = 57.352 uV, v_off_fin = 63.857 uV 15:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.810 uVs 15:30:36 Integrated Voltage Measurement... 15:30:45 Voltage Offset Correction: v_off_ini = 75.055 uV, v_off_fin = 83.627 uV 15:30:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.310 uVs 15:30:49 I1Y Average and RMS of Measurements VT = -240.003 +- 1.114 uVs I1Y = -48.001 +- 0.223 uTm 15:30:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:30:57 Integrated Voltage Measurement... 15:31:06 Voltage Offset Correction: v_off_ini = 83.739 uV, v_off_fin = 71.315 uV 15:31:06 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -38.667 uVs 15:31:06 Integrated Voltage Measurement... 15:31:15 Voltage Offset Correction: v_off_ini = 65.073 uV, v_off_fin = 73.381 uV 15:31:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.499 uVs 15:31:15 Integrated Voltage Measurement... 15:31:24 Voltage Offset Correction: v_off_ini = 71.744 uV, v_off_fin = 59.092 uV 15:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.318 uVs 15:31:24 Integrated Voltage Measurement... 15:31:33 Voltage Offset Correction: v_off_ini = 68.450 uV, v_off_fin = 77.313 uV 15:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.894 uVs 15:31:33 Integrated Voltage Measurement... 15:31:42 Voltage Offset Correction: v_off_ini = 79.265 uV, v_off_fin = 63.823 uV 15:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.931 uVs 15:31:42 Integrated Voltage Measurement... 15:31:51 Voltage Offset Correction: v_off_ini = 73.861 uV, v_off_fin = 87.977 uV 15:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.731 uVs 15:31:54 I2X Average and RMS of Measurements VT = -62.340 +- 7.774 uVs I2X = 5.735 +- 0.715 uTm^2 15:31:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:32:01 Integrated Voltage Measurement... 15:32:10 Voltage Offset Correction: v_off_ini = 81.711 uV, v_off_fin = 80.210 uV 15:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.135 uVs 15:32:10 Integrated Voltage Measurement... 15:32:19 Voltage Offset Correction: v_off_ini = 71.432 uV, v_off_fin = 68.667 uV 15:32:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.653 uVs 15:32:19 Integrated Voltage Measurement... 15:32:28 Voltage Offset Correction: v_off_ini = 79.042 uV, v_off_fin = 80.716 uV 15:32:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.175 uVs 15:32:28 Integrated Voltage Measurement... 15:32:37 Voltage Offset Correction: v_off_ini = 83.006 uV, v_off_fin = 70.739 uV 15:32:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.283 uVs 15:32:37 Integrated Voltage Measurement... 15:32:46 Voltage Offset Correction: v_off_ini = 77.737 uV, v_off_fin = 80.115 uV 15:32:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.984 uVs 15:32:47 Integrated Voltage Measurement... 15:32:55 Voltage Offset Correction: v_off_ini = 78.532 uV, v_off_fin = 66.529 uV 15:32:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.418 uVs 15:32:58 I2Y Average and RMS of Measurements VT = -203.941 +- 7.113 uVs I2Y = -18.763 +- 0.654 uTm^2 15:33:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:33:07 Integrated Voltage Measurement... 15:33:16 Voltage Offset Correction: v_off_ini = 76.761 uV, v_off_fin = 62.369 uV 15:33:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.773 uVs 15:33:16 Integrated Voltage Measurement... 15:33:25 Voltage Offset Correction: v_off_ini = 57.927 uV, v_off_fin = 71.092 uV 15:33:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.152 uVs 15:33:25 Integrated Voltage Measurement... 15:33:34 Voltage Offset Correction: v_off_ini = 72.086 uV, v_off_fin = 70.513 uV 15:33:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -107.628 uVs 15:33:34 Integrated Voltage Measurement... 15:33:43 Voltage Offset Correction: v_off_ini = 60.484 uV, v_off_fin = 71.129 uV 15:33:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.189 uVs 15:33:43 Integrated Voltage Measurement... 15:33:52 Voltage Offset Correction: v_off_ini = 68.666 uV, v_off_fin = 67.955 uV 15:33:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.268 uVs 15:33:52 Integrated Voltage Measurement... 15:34:01 Voltage Offset Correction: v_off_ini = 66.926 uV, v_off_fin = 68.274 uV 15:34:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.562 uVs 15:34:05 I1X Average and RMS of Measurements VT = -96.429 +- 6.301 uVs I1X = 19.286 +- 1.260 uTm 15:34:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:34:12 Integrated Voltage Measurement... 15:34:21 Voltage Offset Correction: v_off_ini = 65.672 uV, v_off_fin = 55.249 uV 15:34:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.793 uVs 15:34:21 Integrated Voltage Measurement... 15:34:30 Voltage Offset Correction: v_off_ini = 68.222 uV, v_off_fin = 80.986 uV 15:34:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.362 uVs 15:34:30 Integrated Voltage Measurement... 15:34:39 Voltage Offset Correction: v_off_ini = 39.565 uV, v_off_fin = 29.543 uV 15:34:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.081 uVs 15:34:39 Integrated Voltage Measurement... 15:34:48 Voltage Offset Correction: v_off_ini = 51.262 uV, v_off_fin = 76.693 uV 15:34:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.077 uVs 15:34:48 Integrated Voltage Measurement... 15:34:57 Voltage Offset Correction: v_off_ini = 55.917 uV, v_off_fin = 51.902 uV 15:34:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.329 uVs 15:34:57 Integrated Voltage Measurement... 15:35:06 Voltage Offset Correction: v_off_ini = 61.433 uV, v_off_fin = 78.857 uV 15:35:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.227 uVs 15:35:10 I1Y Average and RMS of Measurements VT = -216.978 +- 6.942 uVs I1Y = -43.396 +- 1.388 uTm 15:35:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:35:18 Integrated Voltage Measurement... 15:35:27 Voltage Offset Correction: v_off_ini = 52.145 uV, v_off_fin = 56.024 uV 15:35:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -72.482 uVs 15:35:27 Integrated Voltage Measurement... 15:35:36 Voltage Offset Correction: v_off_ini = 63.247 uV, v_off_fin = 69.909 uV 15:35:36 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.960 uVs 15:35:36 Integrated Voltage Measurement... 15:35:45 Voltage Offset Correction: v_off_ini = 53.698 uV, v_off_fin = 47.616 uV 15:35:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.647 uVs 15:35:45 Integrated Voltage Measurement... 15:35:54 Voltage Offset Correction: v_off_ini = 51.679 uV, v_off_fin = 76.448 uV 15:35:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.125 uVs 15:35:54 Integrated Voltage Measurement... 15:36:03 Voltage Offset Correction: v_off_ini = 64.825 uV, v_off_fin = 55.263 uV 15:36:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.604 uVs 15:36:03 Integrated Voltage Measurement... 15:36:12 Voltage Offset Correction: v_off_ini = 77.618 uV, v_off_fin = 85.638 uV 15:36:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.879 uVs 15:36:14 I2X Average and RMS of Measurements VT = -70.283 +- 6.417 uVs I2X = 6.466 +- 0.590 uTm^2 15:36:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:36:22 Integrated Voltage Measurement... 15:36:31 Voltage Offset Correction: v_off_ini = 80.138 uV, v_off_fin = 55.143 uV 15:36:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.403 uVs 15:36:31 Integrated Voltage Measurement... 15:36:40 Voltage Offset Correction: v_off_ini = 63.323 uV, v_off_fin = 65.581 uV 15:36:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.918 uVs 15:36:40 Integrated Voltage Measurement... 15:36:49 Voltage Offset Correction: v_off_ini = 86.599 uV, v_off_fin = 70.083 uV 15:36:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.076 uVs 15:36:49 Integrated Voltage Measurement... 15:36:58 Voltage Offset Correction: v_off_ini = 76.587 uV, v_off_fin = 87.410 uV 15:36:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.545 uVs 15:36:58 Integrated Voltage Measurement... 15:37:07 Voltage Offset Correction: v_off_ini = 79.010 uV, v_off_fin = 71.268 uV 15:37:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.851 uVs 15:37:07 Integrated Voltage Measurement... 15:37:16 Voltage Offset Correction: v_off_ini = 78.970 uV, v_off_fin = 77.351 uV 15:37:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.062 uVs 15:37:19 I2Y Average and RMS of Measurements VT = -194.643 +- 3.303 uVs I2Y = -17.907 +- 0.304 uTm^2 15:37:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:37:28 Integrated Voltage Measurement... 15:37:37 Voltage Offset Correction: v_off_ini = 72.174 uV, v_off_fin = 85.594 uV 15:37:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -113.944 uVs 15:37:37 Integrated Voltage Measurement... 15:37:46 Voltage Offset Correction: v_off_ini = 81.876 uV, v_off_fin = 82.417 uV 15:37:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.737 uVs 15:37:46 Integrated Voltage Measurement... 15:37:55 Voltage Offset Correction: v_off_ini = 93.647 uV, v_off_fin = 87.023 uV 15:37:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.787 uVs 15:37:55 Integrated Voltage Measurement... 15:38:04 Voltage Offset Correction: v_off_ini = 80.280 uV, v_off_fin = 88.107 uV 15:38:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.372 uVs 15:38:04 Integrated Voltage Measurement... 15:38:13 Voltage Offset Correction: v_off_ini = 81.303 uV, v_off_fin = 59.104 uV 15:38:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.767 uVs 15:38:13 Integrated Voltage Measurement... 15:38:22 Voltage Offset Correction: v_off_ini = 78.616 uV, v_off_fin = 75.682 uV 15:38:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.192 uVs 15:38:26 I1X Average and RMS of Measurements VT = -99.133 +- 7.286 uVs I1X = 19.827 +- 1.457 uTm 15:38:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:38:32 Integrated Voltage Measurement... 15:38:41 Voltage Offset Correction: v_off_ini = 77.356 uV, v_off_fin = 69.737 uV 15:38:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.613 uVs 15:38:41 Integrated Voltage Measurement... 15:38:50 Voltage Offset Correction: v_off_ini = 90.320 uV, v_off_fin = 81.913 uV 15:38:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.854 uVs 15:38:50 Integrated Voltage Measurement... 15:38:59 Voltage Offset Correction: v_off_ini = 69.024 uV, v_off_fin = 65.851 uV 15:38:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.273 uVs 15:38:59 Integrated Voltage Measurement... 15:39:08 Voltage Offset Correction: v_off_ini = 60.910 uV, v_off_fin = 68.246 uV 15:39:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.036 uVs 15:39:08 Integrated Voltage Measurement... 15:39:17 Voltage Offset Correction: v_off_ini = 57.065 uV, v_off_fin = 71.772 uV 15:39:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.553 uVs 15:39:17 Integrated Voltage Measurement... 15:39:26 Voltage Offset Correction: v_off_ini = 68.500 uV, v_off_fin = 78.801 uV 15:39:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.627 uVs 15:39:30 I1Y Average and RMS of Measurements VT = -214.326 +- 7.517 uVs I1Y = -42.865 +- 1.503 uTm 15:39:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:39:38 Integrated Voltage Measurement... 15:39:47 Voltage Offset Correction: v_off_ini = 59.454 uV, v_off_fin = 49.501 uV 15:39:47 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -78.688 uVs 15:39:47 Integrated Voltage Measurement... 15:39:56 Voltage Offset Correction: v_off_ini = 63.963 uV, v_off_fin = 62.075 uV 15:39:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.650 uVs 15:39:56 Integrated Voltage Measurement... 15:40:05 Voltage Offset Correction: v_off_ini = 45.984 uV, v_off_fin = 47.904 uV 15:40:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.560 uVs 15:40:05 Integrated Voltage Measurement... 15:40:14 Voltage Offset Correction: v_off_ini = 58.124 uV, v_off_fin = 68.373 uV 15:40:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.370 uVs 15:40:14 Integrated Voltage Measurement... 15:40:23 Voltage Offset Correction: v_off_ini = 73.065 uV, v_off_fin = 63.880 uV 15:40:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.114 uVs 15:40:23 Integrated Voltage Measurement... 15:40:32 Voltage Offset Correction: v_off_ini = 69.082 uV, v_off_fin = 72.430 uV 15:40:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.959 uVs 15:40:35 I2X Average and RMS of Measurements VT = -77.557 +- 3.976 uVs I2X = 7.135 +- 0.366 uTm^2 15:40:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:40:42 Integrated Voltage Measurement... 15:40:51 Voltage Offset Correction: v_off_ini = 79.260 uV, v_off_fin = 70.726 uV 15:40:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.795 uVs 15:40:51 Integrated Voltage Measurement... 15:41:00 Voltage Offset Correction: v_off_ini = 79.933 uV, v_off_fin = 69.576 uV 15:41:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 187.886 uVs 15:41:00 Integrated Voltage Measurement... 15:41:09 Voltage Offset Correction: v_off_ini = 58.171 uV, v_off_fin = 66.890 uV 15:41:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.207 uVs 15:41:09 Integrated Voltage Measurement... 15:41:18 Voltage Offset Correction: v_off_ini = 83.620 uV, v_off_fin = 77.871 uV 15:41:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.706 uVs 15:41:18 Integrated Voltage Measurement... 15:41:27 Voltage Offset Correction: v_off_ini = 74.629 uV, v_off_fin = 69.078 uV 15:41:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.245 uVs 15:41:27 Integrated Voltage Measurement... 15:41:36 Voltage Offset Correction: v_off_ini = 59.867 uV, v_off_fin = 67.900 uV 15:41:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.914 uVs 15:41:39 I2Y Average and RMS of Measurements VT = -187.959 +- 9.030 uVs I2Y = -17.293 +- 0.831 uTm^2 15:41:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:41:48 Integrated Voltage Measurement... 15:41:56 Voltage Offset Correction: v_off_ini = 94.771 uV, v_off_fin = 93.342 uV 15:41:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -117.130 uVs 15:41:56 Integrated Voltage Measurement... 15:42:05 Voltage Offset Correction: v_off_ini = 110.533 uV, v_off_fin = 98.078 uV 15:42:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.061 uVs 15:42:05 Integrated Voltage Measurement... 15:42:14 Voltage Offset Correction: v_off_ini = 91.660 uV, v_off_fin = 70.806 uV 15:42:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.074 uVs 15:42:14 Integrated Voltage Measurement... 15:42:23 Voltage Offset Correction: v_off_ini = 71.995 uV, v_off_fin = 81.569 uV 15:42:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.631 uVs 15:42:23 Integrated Voltage Measurement... 15:42:32 Voltage Offset Correction: v_off_ini = 73.327 uV, v_off_fin = 84.763 uV 15:42:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.765 uVs 15:42:32 Integrated Voltage Measurement... 15:42:41 Voltage Offset Correction: v_off_ini = 61.378 uV, v_off_fin = 73.303 uV 15:42:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.933 uVs 15:42:46 I1X Average and RMS of Measurements VT = -101.766 +- 12.666 uVs I1X = 20.354 +- 2.534 uTm 15:42:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:42:52 Integrated Voltage Measurement... 15:43:01 Voltage Offset Correction: v_off_ini = 73.878 uV, v_off_fin = 75.503 uV 15:43:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.360 uVs 15:43:01 Integrated Voltage Measurement... 15:43:10 Voltage Offset Correction: v_off_ini = 64.783 uV, v_off_fin = 67.340 uV 15:43:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.243 uVs 15:43:10 Integrated Voltage Measurement... 15:43:19 Voltage Offset Correction: v_off_ini = 51.598 uV, v_off_fin = 55.893 uV 15:43:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.754 uVs 15:43:19 Integrated Voltage Measurement... 15:43:28 Voltage Offset Correction: v_off_ini = 68.690 uV, v_off_fin = 77.249 uV 15:43:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.382 uVs 15:43:28 Integrated Voltage Measurement... 15:43:37 Voltage Offset Correction: v_off_ini = 73.892 uV, v_off_fin = 57.725 uV 15:43:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.895 uVs 15:43:37 Integrated Voltage Measurement... 15:43:46 Voltage Offset Correction: v_off_ini = 70.965 uV, v_off_fin = 86.481 uV 15:43:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 183.899 uVs 15:43:50 I1Y Average and RMS of Measurements VT = -199.922 +- 5.085 uVs I1Y = -39.984 +- 1.017 uTm 15:43:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:43:58 Integrated Voltage Measurement... 15:44:07 Voltage Offset Correction: v_off_ini = 84.928 uV, v_off_fin = 57.076 uV 15:44:07 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -87.001 uVs 15:44:07 Integrated Voltage Measurement... 15:44:16 Voltage Offset Correction: v_off_ini = 88.007 uV, v_off_fin = 103.728 uV 15:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.339 uVs 15:44:16 Integrated Voltage Measurement... 15:44:25 Voltage Offset Correction: v_off_ini = 91.228 uV, v_off_fin = 74.095 uV 15:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -111.742 uVs 15:44:25 Integrated Voltage Measurement... 15:44:34 Voltage Offset Correction: v_off_ini = 77.246 uV, v_off_fin = 88.254 uV 15:44:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.052 uVs 15:44:34 Integrated Voltage Measurement... 15:44:43 Voltage Offset Correction: v_off_ini = 74.742 uV, v_off_fin = 72.326 uV 15:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.196 uVs 15:44:43 Integrated Voltage Measurement... 15:44:52 Voltage Offset Correction: v_off_ini = 69.760 uV, v_off_fin = 93.588 uV 15:44:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.468 uVs 15:44:54 I2X Average and RMS of Measurements VT = -87.633 +- 8.878 uVs I2X = 8.062 +- 0.817 uTm^2 15:44:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:45:02 Integrated Voltage Measurement... 15:45:11 Voltage Offset Correction: v_off_ini = 61.146 uV, v_off_fin = 73.500 uV 15:45:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.387 uVs 15:45:11 Integrated Voltage Measurement... 15:45:20 Voltage Offset Correction: v_off_ini = 68.996 uV, v_off_fin = 68.947 uV 15:45:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.076 uVs 15:45:20 Integrated Voltage Measurement... 15:45:29 Voltage Offset Correction: v_off_ini = 68.629 uV, v_off_fin = 68.541 uV 15:45:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.492 uVs 15:45:29 Integrated Voltage Measurement... 15:45:38 Voltage Offset Correction: v_off_ini = 59.915 uV, v_off_fin = 70.682 uV 15:45:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.625 uVs 15:45:38 Integrated Voltage Measurement... 15:45:47 Voltage Offset Correction: v_off_ini = 68.121 uV, v_off_fin = 56.917 uV 15:45:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.685 uVs 15:45:47 Integrated Voltage Measurement... 15:45:56 Voltage Offset Correction: v_off_ini = 61.171 uV, v_off_fin = 66.776 uV 15:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.338 uVs 15:45:58 I2Y Average and RMS of Measurements VT = -171.767 +- 1.249 uVs I2Y = -15.803 +- 0.115 uTm^2 15:46:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:46:10 Integrated Voltage Measurement... 15:46:19 Voltage Offset Correction: v_off_ini = 81.126 uV, v_off_fin = 78.581 uV 15:46:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -88.987 uVs 15:46:19 Integrated Voltage Measurement... 15:46:28 Voltage Offset Correction: v_off_ini = 59.452 uV, v_off_fin = 79.891 uV 15:46:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.875 uVs 15:46:28 Integrated Voltage Measurement... 15:46:37 Voltage Offset Correction: v_off_ini = 73.108 uV, v_off_fin = 68.614 uV 15:46:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.806 uVs 15:46:37 Integrated Voltage Measurement... 15:46:46 Voltage Offset Correction: v_off_ini = 71.695 uV, v_off_fin = 71.023 uV 15:46:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.885 uVs 15:46:46 Integrated Voltage Measurement... 15:46:55 Voltage Offset Correction: v_off_ini = 53.459 uV, v_off_fin = 55.492 uV 15:46:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -51.620 uVs 15:46:55 Integrated Voltage Measurement... 15:47:04 Voltage Offset Correction: v_off_ini = 55.217 uV, v_off_fin = 62.347 uV 15:47:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 58.355 uVs 15:47:09 I1X Average and RMS of Measurements VT = -66.421 +- 8.299 uVs I1X = 13.285 +- 1.659 uTm 15:47:11 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:47:15 Integrated Voltage Measurement... 15:47:24 Voltage Offset Correction: v_off_ini = 72.955 uV, v_off_fin = 50.653 uV 15:47:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.489 uVs 15:47:24 Integrated Voltage Measurement... 15:47:33 Voltage Offset Correction: v_off_ini = 73.940 uV, v_off_fin = 77.011 uV 15:47:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.761 uVs 15:47:33 Integrated Voltage Measurement... 15:47:42 Voltage Offset Correction: v_off_ini = 78.185 uV, v_off_fin = 72.552 uV 15:47:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.328 uVs 15:47:42 Integrated Voltage Measurement... 15:47:51 Voltage Offset Correction: v_off_ini = 65.777 uV, v_off_fin = 89.883 uV 15:47:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.111 uVs 15:47:51 Integrated Voltage Measurement... 15:48:00 Voltage Offset Correction: v_off_ini = 72.824 uV, v_off_fin = 61.265 uV 15:48:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.050 uVs 15:48:00 Integrated Voltage Measurement... 15:48:09 Voltage Offset Correction: v_off_ini = 76.381 uV, v_off_fin = 73.349 uV 15:48:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.638 uVs 15:48:13 I1Y Average and RMS of Measurements VT = -215.896 +- 0.538 uVs I1Y = -43.180 +- 0.107 uTm 15:48:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:48:18 Integrated Voltage Measurement... 15:48:27 Voltage Offset Correction: v_off_ini = 79.220 uV, v_off_fin = 75.313 uV 15:48:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.744 uVs 15:48:27 Integrated Voltage Measurement... 15:48:36 Voltage Offset Correction: v_off_ini = 84.708 uV, v_off_fin = 91.745 uV 15:48:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.686 uVs 15:48:36 Integrated Voltage Measurement... 15:48:45 Voltage Offset Correction: v_off_ini = 69.971 uV, v_off_fin = 70.417 uV 15:48:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.708 uVs 15:48:45 Integrated Voltage Measurement... 15:48:54 Voltage Offset Correction: v_off_ini = 86.612 uV, v_off_fin = 79.288 uV 15:48:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 34.466 uVs 15:48:54 Integrated Voltage Measurement... 15:49:03 Voltage Offset Correction: v_off_ini = 79.690 uV, v_off_fin = 75.134 uV 15:49:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.336 uVs 15:49:04 Integrated Voltage Measurement... 15:49:12 Voltage Offset Correction: v_off_ini = 85.887 uV, v_off_fin = 96.905 uV 15:49:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.428 uVs 15:49:15 I2X Average and RMS of Measurements VT = -42.728 +- 5.585 uVs I2X = 3.931 +- 0.514 uTm^2 15:49:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:49:20 Integrated Voltage Measurement... 15:49:29 Voltage Offset Correction: v_off_ini = 86.386 uV, v_off_fin = 67.539 uV 15:49:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -176.676 uVs 15:49:29 Integrated Voltage Measurement... 15:49:38 Voltage Offset Correction: v_off_ini = 76.279 uV, v_off_fin = 80.261 uV 15:49:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.887 uVs 15:49:38 Integrated Voltage Measurement... 15:49:47 Voltage Offset Correction: v_off_ini = 85.965 uV, v_off_fin = 69.517 uV 15:49:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.317 uVs 15:49:47 Integrated Voltage Measurement... 15:49:56 Voltage Offset Correction: v_off_ini = 86.703 uV, v_off_fin = 82.937 uV 15:49:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.943 uVs 15:49:56 Integrated Voltage Measurement... 15:50:05 Voltage Offset Correction: v_off_ini = 68.655 uV, v_off_fin = 75.315 uV 15:50:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.658 uVs 15:50:05 Integrated Voltage Measurement... 15:50:14 Voltage Offset Correction: v_off_ini = 67.558 uV, v_off_fin = 52.309 uV 15:50:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.193 uVs 15:50:17 I2Y Average and RMS of Measurements VT = -182.112 +- 3.076 uVs I2Y = -16.754 +- 0.283 uTm^2 15:50:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:50:25 Integrated Voltage Measurement... 15:50:34 Voltage Offset Correction: v_off_ini = 85.357 uV, v_off_fin = 66.968 uV 15:50:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.751 uVs 15:50:34 Integrated Voltage Measurement... 15:50:43 Voltage Offset Correction: v_off_ini = 75.383 uV, v_off_fin = 76.879 uV 15:50:43 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.371 uVs 15:50:43 Integrated Voltage Measurement... 15:50:52 Voltage Offset Correction: v_off_ini = 70.242 uV, v_off_fin = 76.144 uV 15:50:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.853 uVs 15:50:52 Integrated Voltage Measurement... 15:51:01 Voltage Offset Correction: v_off_ini = 71.655 uV, v_off_fin = 76.145 uV 15:51:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.761 uVs 15:51:01 Integrated Voltage Measurement... 15:51:10 Voltage Offset Correction: v_off_ini = 92.413 uV, v_off_fin = 68.913 uV 15:51:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.572 uVs 15:51:10 Integrated Voltage Measurement... 15:51:19 Voltage Offset Correction: v_off_ini = 77.528 uV, v_off_fin = 88.623 uV 15:51:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 98.634 uVs 15:51:23 I1X Average and RMS of Measurements VT = -83.157 +- 6.901 uVs I1X = 16.632 +- 1.380 uTm 15:51:26 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:51:30 Integrated Voltage Measurement... 15:51:39 Voltage Offset Correction: v_off_ini = 106.411 uV, v_off_fin = 94.083 uV 15:51:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.921 uVs 15:51:39 Integrated Voltage Measurement... 15:51:48 Voltage Offset Correction: v_off_ini = 110.486 uV, v_off_fin = 112.939 uV 15:51:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.377 uVs 15:51:48 Integrated Voltage Measurement... 15:51:57 Voltage Offset Correction: v_off_ini = 106.165 uV, v_off_fin = 103.964 uV 15:51:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.824 uVs 15:51:57 Integrated Voltage Measurement... 15:52:06 Voltage Offset Correction: v_off_ini = 96.939 uV, v_off_fin = 112.520 uV 15:52:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.347 uVs 15:52:06 Integrated Voltage Measurement... 15:52:15 Voltage Offset Correction: v_off_ini = 109.040 uV, v_off_fin = 99.622 uV 15:52:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.562 uVs 15:52:15 Integrated Voltage Measurement... 15:52:24 Voltage Offset Correction: v_off_ini = 97.158 uV, v_off_fin = 105.580 uV 15:52:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.931 uVs 15:52:28 I1Y Average and RMS of Measurements VT = -226.160 +- 5.123 uVs I1Y = -45.232 +- 1.025 uTm 15:52:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:52:33 Integrated Voltage Measurement... 15:52:42 Voltage Offset Correction: v_off_ini = 89.868 uV, v_off_fin = 82.188 uV 15:52:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.051 uVs 15:52:42 Integrated Voltage Measurement... 15:52:51 Voltage Offset Correction: v_off_ini = 81.465 uV, v_off_fin = 93.322 uV 15:52:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.967 uVs 15:52:51 Integrated Voltage Measurement... 15:53:00 Voltage Offset Correction: v_off_ini = 82.222 uV, v_off_fin = 77.028 uV 15:53:00 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -65.507 uVs 15:53:00 Integrated Voltage Measurement... 15:53:09 Voltage Offset Correction: v_off_ini = 82.438 uV, v_off_fin = 96.804 uV 15:53:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.626 uVs 15:53:09 Integrated Voltage Measurement... 15:53:18 Voltage Offset Correction: v_off_ini = 89.541 uV, v_off_fin = 80.064 uV 15:53:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.964 uVs 15:53:18 Integrated Voltage Measurement... 15:53:27 Voltage Offset Correction: v_off_ini = 86.084 uV, v_off_fin = 105.485 uV 15:53:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.570 uVs 15:53:30 I2X Average and RMS of Measurements VT = -59.781 +- 6.163 uVs I2X = 5.500 +- 0.567 uTm^2 15:53:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:53:35 Integrated Voltage Measurement... 15:53:44 Voltage Offset Correction: v_off_ini = 89.594 uV, v_off_fin = 92.071 uV 15:53:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.709 uVs 15:53:44 Integrated Voltage Measurement... 15:53:53 Voltage Offset Correction: v_off_ini = 87.852 uV, v_off_fin = 93.687 uV 15:53:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.899 uVs 15:53:53 Integrated Voltage Measurement... 15:54:02 Voltage Offset Correction: v_off_ini = 83.180 uV, v_off_fin = 86.476 uV 15:54:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.861 uVs 15:54:02 Integrated Voltage Measurement... 15:54:11 Voltage Offset Correction: v_off_ini = 95.270 uV, v_off_fin = 83.901 uV 15:54:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.209 uVs 15:54:11 Integrated Voltage Measurement... 15:54:20 Voltage Offset Correction: v_off_ini = 107.941 uV, v_off_fin = 87.832 uV 15:54:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.970 uVs 15:54:20 Integrated Voltage Measurement... 15:54:29 Voltage Offset Correction: v_off_ini = 94.177 uV, v_off_fin = 91.865 uV 15:54:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.533 uVs 15:54:31 I2Y Average and RMS of Measurements VT = -185.197 +- 6.679 uVs I2Y = -17.038 +- 0.614 uTm^2 15:54:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:54:39 Integrated Voltage Measurement... 15:54:48 Voltage Offset Correction: v_off_ini = 78.691 uV, v_off_fin = 104.049 uV 15:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -115.119 uVs 15:54:48 Integrated Voltage Measurement... 15:54:57 Voltage Offset Correction: v_off_ini = 102.406 uV, v_off_fin = 83.779 uV 15:54:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.903 uVs 15:54:57 Integrated Voltage Measurement... 15:55:06 Voltage Offset Correction: v_off_ini = 77.188 uV, v_off_fin = 92.800 uV 15:55:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.520 uVs 15:55:06 Integrated Voltage Measurement... 15:55:15 Voltage Offset Correction: v_off_ini = 95.383 uV, v_off_fin = 95.821 uV 15:55:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.600 uVs 15:55:15 Integrated Voltage Measurement... 15:55:24 Voltage Offset Correction: v_off_ini = 98.021 uV, v_off_fin = 86.145 uV 15:55:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.443 uVs 15:55:24 Integrated Voltage Measurement... 15:55:33 Voltage Offset Correction: v_off_ini = 78.836 uV, v_off_fin = 91.996 uV 15:55:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.633 uVs 15:55:38 I1X Average and RMS of Measurements VT = -89.536 +- 9.614 uVs I1X = 17.908 +- 1.923 uTm 15:55:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:55:44 Integrated Voltage Measurement... 15:55:53 Voltage Offset Correction: v_off_ini = 99.198 uV, v_off_fin = 78.321 uV 15:55:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.510 uVs 15:55:53 Integrated Voltage Measurement... 15:56:02 Voltage Offset Correction: v_off_ini = 99.179 uV, v_off_fin = 101.942 uV 15:56:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.517 uVs 15:56:02 Integrated Voltage Measurement... 15:56:11 Voltage Offset Correction: v_off_ini = 88.315 uV, v_off_fin = 89.711 uV 15:56:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.417 uVs 15:56:11 Integrated Voltage Measurement... 15:56:20 Voltage Offset Correction: v_off_ini = 96.545 uV, v_off_fin = 116.024 uV 15:56:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.783 uVs 15:56:20 Integrated Voltage Measurement... 15:56:29 Voltage Offset Correction: v_off_ini = 95.772 uV, v_off_fin = 86.984 uV 15:56:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.809 uVs 15:56:29 Integrated Voltage Measurement... 15:56:38 Voltage Offset Correction: v_off_ini = 96.630 uV, v_off_fin = 97.888 uV 15:56:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.539 uVs 15:56:42 I1Y Average and RMS of Measurements VT = -224.263 +- 6.050 uVs I1Y = -44.853 +- 1.210 uTm 15:56:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:56:48 Integrated Voltage Measurement... 15:56:57 Voltage Offset Correction: v_off_ini = 78.875 uV, v_off_fin = 77.758 uV 15:56:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.409 uVs 15:56:57 Integrated Voltage Measurement... 15:57:06 Voltage Offset Correction: v_off_ini = 71.137 uV, v_off_fin = 84.245 uV 15:57:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 68.983 uVs 15:57:06 Integrated Voltage Measurement... 15:57:15 Voltage Offset Correction: v_off_ini = 90.854 uV, v_off_fin = 69.127 uV 15:57:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.622 uVs 15:57:15 Integrated Voltage Measurement... 15:57:24 Voltage Offset Correction: v_off_ini = 76.820 uV, v_off_fin = 88.510 uV 15:57:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.440 uVs 15:57:24 Integrated Voltage Measurement... 15:57:33 Voltage Offset Correction: v_off_ini = 73.020 uV, v_off_fin = 59.986 uV 15:57:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.387 uVs 15:57:33 Integrated Voltage Measurement... 15:57:42 Voltage Offset Correction: v_off_ini = 84.373 uV, v_off_fin = 92.465 uV 15:57:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.157 uVs 15:57:44 I2X Average and RMS of Measurements VT = -69.500 +- 0.582 uVs I2X = 6.394 +- 0.054 uTm^2 15:57:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:57:49 Integrated Voltage Measurement... 15:57:58 Voltage Offset Correction: v_off_ini = 86.795 uV, v_off_fin = 86.783 uV 15:57:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.139 uVs 15:57:58 Integrated Voltage Measurement... 15:58:07 Voltage Offset Correction: v_off_ini = 94.106 uV, v_off_fin = 99.935 uV 15:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.039 uVs 15:58:07 Integrated Voltage Measurement... 15:58:16 Voltage Offset Correction: v_off_ini = 93.061 uV, v_off_fin = 93.850 uV 15:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.452 uVs 15:58:16 Integrated Voltage Measurement... 15:58:25 Voltage Offset Correction: v_off_ini = 99.003 uV, v_off_fin = 99.898 uV 15:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.546 uVs 15:58:25 Integrated Voltage Measurement... 15:58:34 Voltage Offset Correction: v_off_ini = 103.819 uV, v_off_fin = 92.968 uV 15:58:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.429 uVs 15:58:34 Integrated Voltage Measurement... 15:58:43 Voltage Offset Correction: v_off_ini = 101.304 uV, v_off_fin = 106.534 uV 15:58:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.699 uVs 15:58:46 I2Y Average and RMS of Measurements VT = -191.217 +- 1.042 uVs I2Y = -17.592 +- 0.096 uTm^2 15:58:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:58:54 Integrated Voltage Measurement... 15:59:03 Voltage Offset Correction: v_off_ini = 112.507 uV, v_off_fin = 113.219 uV 15:59:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -95.246 uVs 15:59:03 Integrated Voltage Measurement... 15:59:12 Voltage Offset Correction: v_off_ini = 100.109 uV, v_off_fin = 91.852 uV 15:59:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.373 uVs 15:59:12 Integrated Voltage Measurement... 15:59:21 Voltage Offset Correction: v_off_ini = 93.509 uV, v_off_fin = 98.061 uV 15:59:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.584 uVs 15:59:21 Integrated Voltage Measurement... 15:59:30 Voltage Offset Correction: v_off_ini = 116.685 uV, v_off_fin = 102.765 uV 15:59:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.515 uVs 15:59:30 Integrated Voltage Measurement... 15:59:39 Voltage Offset Correction: v_off_ini = 102.378 uV, v_off_fin = 119.591 uV 15:59:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.171 uVs 15:59:39 Integrated Voltage Measurement... 15:59:48 Voltage Offset Correction: v_off_ini = 124.476 uV, v_off_fin = 119.309 uV 15:59:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.809 uVs 15:59:52 I1X Average and RMS of Measurements VT = -93.950 +- 4.362 uVs I1X = 18.790 +- 0.873 uTm 15:59:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:59:59 Integrated Voltage Measurement... 16:00:08 Voltage Offset Correction: v_off_ini = 102.262 uV, v_off_fin = 97.532 uV 16:00:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.348 uVs 16:00:08 Integrated Voltage Measurement... 16:00:17 Voltage Offset Correction: v_off_ini = 86.364 uV, v_off_fin = 101.512 uV 16:00:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.497 uVs 16:00:17 Integrated Voltage Measurement... 16:00:26 Voltage Offset Correction: v_off_ini = 96.895 uV, v_off_fin = 82.346 uV 16:00:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -224.087 uVs 16:00:26 Integrated Voltage Measurement... 16:00:35 Voltage Offset Correction: v_off_ini = 98.273 uV, v_off_fin = 106.858 uV 16:00:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 236.947 uVs 16:00:35 Integrated Voltage Measurement... 16:00:44 Voltage Offset Correction: v_off_ini = 104.269 uV, v_off_fin = 88.515 uV 16:00:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.290 uVs 16:00:44 Integrated Voltage Measurement... 16:00:53 Voltage Offset Correction: v_off_ini = 86.702 uV, v_off_fin = 109.173 uV 16:00:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.670 uVs 16:00:57 I1Y Average and RMS of Measurements VT = -230.140 +- 2.847 uVs I1Y = -46.026 +- 0.569 uTm 16:01:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:01:02 Integrated Voltage Measurement... 16:01:11 Voltage Offset Correction: v_off_ini = 100.654 uV, v_off_fin = 78.100 uV 16:01:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.739 uVs 16:01:11 Integrated Voltage Measurement... 16:01:20 Voltage Offset Correction: v_off_ini = 91.551 uV, v_off_fin = 91.631 uV 16:01:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 64.525 uVs 16:01:20 Integrated Voltage Measurement... 16:01:29 Voltage Offset Correction: v_off_ini = 78.155 uV, v_off_fin = 79.651 uV 16:01:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.367 uVs 16:01:29 Integrated Voltage Measurement... 16:01:38 Voltage Offset Correction: v_off_ini = 66.287 uV, v_off_fin = 75.072 uV 16:01:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.986 uVs 16:01:38 Integrated Voltage Measurement... 16:01:47 Voltage Offset Correction: v_off_ini = 50.379 uV, v_off_fin = 57.572 uV 16:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.076 uVs 16:01:47 Integrated Voltage Measurement... 16:01:56 Voltage Offset Correction: v_off_ini = 55.343 uV, v_off_fin = 71.093 uV 16:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.177 uVs 16:01:59 I2X Average and RMS of Measurements VT = -71.645 +- 6.016 uVs I2X = 6.591 +- 0.553 uTm^2 16:02:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:02:04 Integrated Voltage Measurement... 16:02:13 Voltage Offset Correction: v_off_ini = 68.418 uV, v_off_fin = 60.738 uV 16:02:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.021 uVs 16:02:13 Integrated Voltage Measurement... 16:02:22 Voltage Offset Correction: v_off_ini = 71.173 uV, v_off_fin = 77.310 uV 16:02:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.580 uVs 16:02:22 Integrated Voltage Measurement... 16:02:31 Voltage Offset Correction: v_off_ini = 78.957 uV, v_off_fin = 62.765 uV 16:02:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.282 uVs 16:02:31 Integrated Voltage Measurement... 16:02:40 Voltage Offset Correction: v_off_ini = 86.330 uV, v_off_fin = 78.102 uV 16:02:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.304 uVs 16:02:40 Integrated Voltage Measurement... 16:02:49 Voltage Offset Correction: v_off_ini = 83.018 uV, v_off_fin = 77.475 uV 16:02:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.548 uVs 16:02:49 Integrated Voltage Measurement... 16:02:58 Voltage Offset Correction: v_off_ini = 85.784 uV, v_off_fin = 80.289 uV 16:02:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.774 uVs 16:03:00 I2Y Average and RMS of Measurements VT = -193.751 +- 7.143 uVs I2Y = -17.825 +- 0.657 uTm^2 16:03:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:03:09 Integrated Voltage Measurement... 16:03:18 Voltage Offset Correction: v_off_ini = 86.806 uV, v_off_fin = 73.244 uV 16:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -121.838 uVs 16:03:18 Integrated Voltage Measurement... 16:03:27 Voltage Offset Correction: v_off_ini = 87.127 uV, v_off_fin = 77.484 uV 16:03:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.728 uVs 16:03:27 Integrated Voltage Measurement... 16:03:36 Voltage Offset Correction: v_off_ini = 71.593 uV, v_off_fin = 60.373 uV 16:03:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.966 uVs 16:03:36 Integrated Voltage Measurement... 16:03:45 Voltage Offset Correction: v_off_ini = 90.326 uV, v_off_fin = 76.163 uV 16:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 97.985 uVs 16:03:45 Integrated Voltage Measurement... 16:03:54 Voltage Offset Correction: v_off_ini = 80.629 uV, v_off_fin = 69.691 uV 16:03:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.761 uVs 16:03:54 Integrated Voltage Measurement... 16:04:03 Voltage Offset Correction: v_off_ini = 78.695 uV, v_off_fin = 76.317 uV 16:04:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.571 uVs 16:04:07 I1X Average and RMS of Measurements VT = -96.475 +- 5.876 uVs I1X = 19.295 +- 1.175 uTm 16:04:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:04:14 Integrated Voltage Measurement... 16:04:23 Voltage Offset Correction: v_off_ini = 66.023 uV, v_off_fin = 57.040 uV 16:04:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -231.131 uVs 16:04:23 Integrated Voltage Measurement... 16:04:32 Voltage Offset Correction: v_off_ini = 77.275 uV, v_off_fin = 83.498 uV 16:04:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.640 uVs 16:04:32 Integrated Voltage Measurement... 16:04:41 Voltage Offset Correction: v_off_ini = 78.580 uV, v_off_fin = 66.411 uV 16:04:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.605 uVs 16:04:41 Integrated Voltage Measurement... 16:04:50 Voltage Offset Correction: v_off_ini = 75.731 uV, v_off_fin = 86.716 uV 16:04:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.693 uVs 16:04:50 Integrated Voltage Measurement... 16:04:59 Voltage Offset Correction: v_off_ini = 73.261 uV, v_off_fin = 67.439 uV 16:04:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.562 uVs 16:04:59 Integrated Voltage Measurement... 16:05:08 Voltage Offset Correction: v_off_ini = 75.855 uV, v_off_fin = 85.879 uV 16:05:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.289 uVs 16:05:12 I1Y Average and RMS of Measurements VT = -222.820 +- 2.242 uVs I1Y = -44.563 +- 0.447 uTm 16:05:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:05:17 Integrated Voltage Measurement... 16:05:26 Voltage Offset Correction: v_off_ini = 74.028 uV, v_off_fin = 69.968 uV 16:05:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -74.486 uVs 16:05:26 Integrated Voltage Measurement... 16:05:35 Voltage Offset Correction: v_off_ini = 75.488 uV, v_off_fin = 82.246 uV 16:05:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.471 uVs 16:05:35 Integrated Voltage Measurement... 16:05:44 Voltage Offset Correction: v_off_ini = 78.731 uV, v_off_fin = 75.733 uV 16:05:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.003 uVs 16:05:44 Integrated Voltage Measurement... 16:05:53 Voltage Offset Correction: v_off_ini = 87.400 uV, v_off_fin = 104.413 uV 16:05:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.854 uVs 16:05:53 Integrated Voltage Measurement... 16:06:02 Voltage Offset Correction: v_off_ini = 95.635 uV, v_off_fin = 81.297 uV 16:06:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.809 uVs 16:06:02 Integrated Voltage Measurement... 16:06:11 Voltage Offset Correction: v_off_ini = 74.475 uV, v_off_fin = 101.936 uV 16:06:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 88.728 uVs 16:06:13 I2X Average and RMS of Measurements VT = -77.725 +- 3.040 uVs I2X = 7.151 +- 0.280 uTm^2 16:06:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:06:19 Integrated Voltage Measurement... 16:06:28 Voltage Offset Correction: v_off_ini = 95.380 uV, v_off_fin = 83.128 uV 16:06:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.779 uVs 16:06:28 Integrated Voltage Measurement... 16:06:37 Voltage Offset Correction: v_off_ini = 96.491 uV, v_off_fin = 103.394 uV 16:06:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.514 uVs 16:06:37 Integrated Voltage Measurement... 16:06:46 Voltage Offset Correction: v_off_ini = 86.331 uV, v_off_fin = 70.483 uV 16:06:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -170.535 uVs 16:06:46 Integrated Voltage Measurement... 16:06:55 Voltage Offset Correction: v_off_ini = 80.566 uV, v_off_fin = 67.005 uV 16:06:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.015 uVs 16:06:55 Integrated Voltage Measurement... 16:07:04 Voltage Offset Correction: v_off_ini = 76.544 uV, v_off_fin = 79.334 uV 16:07:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.348 uVs 16:07:04 Integrated Voltage Measurement... 16:07:13 Voltage Offset Correction: v_off_ini = 95.774 uV, v_off_fin = 94.299 uV 16:07:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.804 uVs 16:07:15 I2Y Average and RMS of Measurements VT = -192.833 +- 11.223 uVs I2Y = -17.741 +- 1.033 uTm^2 16:07:32 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:07:36 Integrated Voltage Measurement... 16:07:45 Voltage Offset Correction: v_off_ini = 86.204 uV, v_off_fin = 83.553 uV 16:07:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.156 uVs 16:07:45 Integrated Voltage Measurement... 16:07:54 Voltage Offset Correction: v_off_ini = 85.951 uV, v_off_fin = 84.790 uV 16:07:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.541 uVs 16:07:54 Integrated Voltage Measurement... 16:08:03 Voltage Offset Correction: v_off_ini = 67.593 uV, v_off_fin = 77.493 uV 16:08:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.869 uVs 16:08:03 Integrated Voltage Measurement... 16:08:12 Voltage Offset Correction: v_off_ini = 96.718 uV, v_off_fin = 108.553 uV 16:08:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 55.626 uVs 16:08:12 Integrated Voltage Measurement... 16:08:21 Voltage Offset Correction: v_off_ini = 116.837 uV, v_off_fin = 90.860 uV 16:08:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.110 uVs 16:08:21 Integrated Voltage Measurement... 16:08:30 Voltage Offset Correction: v_off_ini = 90.914 uV, v_off_fin = 93.208 uV 16:08:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.295 uVs 16:08:35 I1X Average and RMS of Measurements VT = -68.933 +- 7.055 uVs I1X = 13.787 +- 1.410 uTm 16:08:37 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:08:41 Integrated Voltage Measurement... 16:08:50 Voltage Offset Correction: v_off_ini = 103.393 uV, v_off_fin = 98.966 uV 16:08:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.535 uVs 16:08:50 Integrated Voltage Measurement... 16:08:59 Voltage Offset Correction: v_off_ini = 98.140 uV, v_off_fin = 113.066 uV 16:08:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 301.231 uVs 16:08:59 Integrated Voltage Measurement... 16:09:08 Voltage Offset Correction: v_off_ini = 84.816 uV, v_off_fin = 83.606 uV 16:09:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.902 uVs 16:09:08 Integrated Voltage Measurement... 16:09:17 Voltage Offset Correction: v_off_ini = 87.291 uV, v_off_fin = 100.313 uV 16:09:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.206 uVs 16:09:17 Integrated Voltage Measurement... 16:09:26 Voltage Offset Correction: v_off_ini = 89.974 uV, v_off_fin = 65.521 uV 16:09:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.464 uVs 16:09:26 Integrated Voltage Measurement... 16:09:35 Voltage Offset Correction: v_off_ini = 80.063 uV, v_off_fin = 103.265 uV 16:09:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 284.125 uVs 16:09:39 I1Y Average and RMS of Measurements VT = -283.911 +- 7.567 uVs I1Y = -56.782 +- 1.513 uTm 16:09:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:09:47 Integrated Voltage Measurement... 16:09:56 Voltage Offset Correction: v_off_ini = 87.140 uV, v_off_fin = 82.922 uV 16:09:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.439 uVs 16:09:56 Integrated Voltage Measurement... 16:10:05 Voltage Offset Correction: v_off_ini = 94.745 uV, v_off_fin = 95.318 uV 16:10:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.738 uVs 16:10:05 Integrated Voltage Measurement... 16:10:14 Voltage Offset Correction: v_off_ini = 85.345 uV, v_off_fin = 72.445 uV 16:10:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -22.098 uVs 16:10:14 Integrated Voltage Measurement... 16:10:23 Voltage Offset Correction: v_off_ini = 93.336 uV, v_off_fin = 87.204 uV 16:10:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.149 uVs 16:10:23 Integrated Voltage Measurement... 16:10:32 Voltage Offset Correction: v_off_ini = 86.791 uV, v_off_fin = 100.874 uV 16:10:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.988 uVs 16:10:32 Integrated Voltage Measurement... 16:10:41 Voltage Offset Correction: v_off_ini = 110.510 uV, v_off_fin = 119.856 uV 16:10:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.075 uVs 16:10:44 I2X Average and RMS of Measurements VT = -33.581 +- 3.225 uVs I2X = 3.089 +- 0.297 uTm^2 16:10:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:10:51 Integrated Voltage Measurement... 16:11:00 Voltage Offset Correction: v_off_ini = 89.020 uV, v_off_fin = 88.384 uV 16:11:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.402 uVs 16:11:01 Integrated Voltage Measurement... 16:11:10 Voltage Offset Correction: v_off_ini = 84.805 uV, v_off_fin = 91.958 uV 16:11:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.684 uVs 16:11:10 Integrated Voltage Measurement... 16:11:19 Voltage Offset Correction: v_off_ini = 84.638 uV, v_off_fin = 95.234 uV 16:11:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.629 uVs 16:11:19 Integrated Voltage Measurement... 16:11:28 Voltage Offset Correction: v_off_ini = 104.102 uV, v_off_fin = 105.094 uV 16:11:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.610 uVs 16:11:28 Integrated Voltage Measurement... 16:11:37 Voltage Offset Correction: v_off_ini = 101.210 uV, v_off_fin = 95.041 uV 16:11:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.431 uVs 16:11:37 Integrated Voltage Measurement... 16:11:46 Voltage Offset Correction: v_off_ini = 86.769 uV, v_off_fin = 84.725 uV 16:11:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.821 uVs 16:11:48 I2Y Average and RMS of Measurements VT = -255.763 +- 8.511 uVs I2Y = -23.530 +- 0.783 uTm^2 16:11:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:11:57 Integrated Voltage Measurement... 16:12:06 Voltage Offset Correction: v_off_ini = 84.949 uV, v_off_fin = 80.006 uV 16:12:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.637 uVs 16:12:06 Integrated Voltage Measurement... 16:12:15 Voltage Offset Correction: v_off_ini = 88.646 uV, v_off_fin = 95.481 uV 16:12:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.521 uVs 16:12:15 Integrated Voltage Measurement... 16:12:24 Voltage Offset Correction: v_off_ini = 90.963 uV, v_off_fin = 83.783 uV 16:12:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.548 uVs 16:12:24 Integrated Voltage Measurement... 16:12:33 Voltage Offset Correction: v_off_ini = 80.509 uV, v_off_fin = 94.674 uV 16:12:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.074 uVs 16:12:33 Integrated Voltage Measurement... 16:12:42 Voltage Offset Correction: v_off_ini = 83.195 uV, v_off_fin = 88.369 uV 16:12:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.816 uVs 16:12:42 Integrated Voltage Measurement... 16:12:51 Voltage Offset Correction: v_off_ini = 98.810 uV, v_off_fin = 92.085 uV 16:12:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.282 uVs 16:12:55 I1X Average and RMS of Measurements VT = -70.980 +- 7.536 uVs I1X = 14.196 +- 1.507 uTm 16:12:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:13:02 Integrated Voltage Measurement... 16:13:11 Voltage Offset Correction: v_off_ini = 97.337 uV, v_off_fin = 105.110 uV 16:13:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.753 uVs 16:13:11 Integrated Voltage Measurement... 16:13:20 Voltage Offset Correction: v_off_ini = 123.416 uV, v_off_fin = 126.777 uV 16:13:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.118 uVs 16:13:20 Integrated Voltage Measurement... 16:13:29 Voltage Offset Correction: v_off_ini = 107.225 uV, v_off_fin = 81.094 uV 16:13:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.781 uVs 16:13:29 Integrated Voltage Measurement... 16:13:38 Voltage Offset Correction: v_off_ini = 97.335 uV, v_off_fin = 99.825 uV 16:13:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.197 uVs 16:13:38 Integrated Voltage Measurement... 16:13:47 Voltage Offset Correction: v_off_ini = 95.218 uV, v_off_fin = 87.406 uV 16:13:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.349 uVs 16:13:47 Integrated Voltage Measurement... 16:13:56 Voltage Offset Correction: v_off_ini = 83.916 uV, v_off_fin = 94.783 uV 16:13:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 287.136 uVs 16:14:00 I1Y Average and RMS of Measurements VT = -269.223 +- 9.384 uVs I1Y = -53.845 +- 1.877 uTm 16:14:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:14:08 Integrated Voltage Measurement... 16:14:17 Voltage Offset Correction: v_off_ini = 98.501 uV, v_off_fin = 103.819 uV 16:14:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.926 uVs 16:14:17 Integrated Voltage Measurement... 16:14:26 Voltage Offset Correction: v_off_ini = 105.918 uV, v_off_fin = 118.264 uV 16:14:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.498 uVs 16:14:26 Integrated Voltage Measurement... 16:14:35 Voltage Offset Correction: v_off_ini = 99.584 uV, v_off_fin = 99.231 uV 16:14:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.315 uVs 16:14:35 Integrated Voltage Measurement... 16:14:44 Voltage Offset Correction: v_off_ini = 109.565 uV, v_off_fin = 118.021 uV 16:14:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.682 uVs 16:14:44 Integrated Voltage Measurement... 16:14:53 Voltage Offset Correction: v_off_ini = 96.627 uV, v_off_fin = 104.641 uV 16:14:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.725 uVs 16:14:53 Integrated Voltage Measurement... 16:15:02 Voltage Offset Correction: v_off_ini = 104.128 uV, v_off_fin = 96.389 uV 16:15:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 33.266 uVs 16:15:05 I2X Average and RMS of Measurements VT = -40.569 +- 2.020 uVs I2X = 3.732 +- 0.186 uTm^2 16:15:10 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:15:12 Integrated Voltage Measurement... 16:15:21 Voltage Offset Correction: v_off_ini = 91.850 uV, v_off_fin = 76.251 uV 16:15:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.285 uVs 16:15:21 Integrated Voltage Measurement... 16:15:30 Voltage Offset Correction: v_off_ini = 103.170 uV, v_off_fin = 102.054 uV 16:15:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.343 uVs 16:15:30 Integrated Voltage Measurement... 16:15:39 Voltage Offset Correction: v_off_ini = 104.963 uV, v_off_fin = 105.508 uV 16:15:39 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -215.533 uVs 16:15:40 Integrated Voltage Measurement... 16:15:48 Voltage Offset Correction: v_off_ini = 123.015 uV, v_off_fin = 125.671 uV 16:15:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.870 uVs 16:15:49 Integrated Voltage Measurement... 16:15:58 Voltage Offset Correction: v_off_ini = 141.283 uV, v_off_fin = 126.660 uV 16:15:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.687 uVs 16:15:58 Integrated Voltage Measurement... 16:16:07 Voltage Offset Correction: v_off_ini = 122.438 uV, v_off_fin = 119.782 uV 16:16:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.017 uVs 16:16:09 I2Y Average and RMS of Measurements VT = -235.289 +- 2.717 uVs I2Y = -21.647 +- 0.250 uTm^2 16:16:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:16:18 Integrated Voltage Measurement... 16:16:27 Voltage Offset Correction: v_off_ini = 145.679 uV, v_off_fin = 136.406 uV 16:16:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.055 uVs 16:16:27 Integrated Voltage Measurement... 16:16:36 Voltage Offset Correction: v_off_ini = 127.649 uV, v_off_fin = 136.135 uV 16:16:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.357 uVs 16:16:36 Integrated Voltage Measurement... 16:16:45 Voltage Offset Correction: v_off_ini = 125.729 uV, v_off_fin = 121.823 uV 16:16:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.992 uVs 16:16:45 Integrated Voltage Measurement... 16:16:54 Voltage Offset Correction: v_off_ini = 124.086 uV, v_off_fin = 106.637 uV 16:16:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.929 uVs 16:16:54 Integrated Voltage Measurement... 16:17:03 Voltage Offset Correction: v_off_ini = 129.471 uV, v_off_fin = 145.776 uV 16:17:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.453 uVs 16:17:03 Integrated Voltage Measurement... 16:17:12 Voltage Offset Correction: v_off_ini = 133.868 uV, v_off_fin = 128.750 uV 16:17:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.130 uVs 16:17:16 I1X Average and RMS of Measurements VT = -78.486 +- 5.595 uVs I1X = 15.697 +- 1.119 uTm 16:17:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:17:23 Integrated Voltage Measurement... 16:17:32 Voltage Offset Correction: v_off_ini = 127.116 uV, v_off_fin = 116.557 uV 16:17:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.786 uVs 16:17:32 Integrated Voltage Measurement... 16:17:41 Voltage Offset Correction: v_off_ini = 127.120 uV, v_off_fin = 143.482 uV 16:17:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.095 uVs 16:17:41 Integrated Voltage Measurement... 16:17:50 Voltage Offset Correction: v_off_ini = 116.823 uV, v_off_fin = 102.036 uV 16:17:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.231 uVs 16:17:50 Integrated Voltage Measurement... 16:17:59 Voltage Offset Correction: v_off_ini = 128.884 uV, v_off_fin = 141.209 uV 16:17:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.841 uVs 16:17:59 Integrated Voltage Measurement... 16:18:08 Voltage Offset Correction: v_off_ini = 138.869 uV, v_off_fin = 132.905 uV 16:18:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.087 uVs 16:18:08 Integrated Voltage Measurement... 16:18:17 Voltage Offset Correction: v_off_ini = 126.727 uV, v_off_fin = 144.565 uV 16:18:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.016 uVs 16:18:21 I1Y Average and RMS of Measurements VT = -247.676 +- 1.851 uVs I1Y = -49.535 +- 0.370 uTm 16:18:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:18:29 Integrated Voltage Measurement... 16:18:38 Voltage Offset Correction: v_off_ini = 144.695 uV, v_off_fin = 128.554 uV 16:18:38 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -62.625 uVs 16:18:38 Integrated Voltage Measurement... 16:18:47 Voltage Offset Correction: v_off_ini = 129.529 uV, v_off_fin = 139.689 uV 16:18:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.659 uVs 16:18:47 Integrated Voltage Measurement... 16:18:56 Voltage Offset Correction: v_off_ini = 139.042 uV, v_off_fin = 131.504 uV 16:18:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.116 uVs 16:18:56 Integrated Voltage Measurement... 16:19:05 Voltage Offset Correction: v_off_ini = 154.618 uV, v_off_fin = 161.319 uV 16:19:05 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 70.619 uVs 16:19:05 Integrated Voltage Measurement... 16:19:14 Voltage Offset Correction: v_off_ini = 137.436 uV, v_off_fin = 124.882 uV 16:19:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -57.177 uVs 16:19:14 Integrated Voltage Measurement... 16:19:23 Voltage Offset Correction: v_off_ini = 131.393 uV, v_off_fin = 143.260 uV 16:19:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.648 uVs 16:19:25 I2X Average and RMS of Measurements VT = -55.974 +- 8.389 uVs I2X = 5.150 +- 0.772 uTm^2 16:19:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:19:33 Integrated Voltage Measurement... 16:19:42 Voltage Offset Correction: v_off_ini = 140.793 uV, v_off_fin = 142.307 uV 16:19:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.148 uVs 16:19:42 Integrated Voltage Measurement... 16:19:51 Voltage Offset Correction: v_off_ini = 128.857 uV, v_off_fin = 139.580 uV 16:19:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.590 uVs 16:19:51 Integrated Voltage Measurement... 16:20:00 Voltage Offset Correction: v_off_ini = 121.004 uV, v_off_fin = 119.388 uV 16:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.721 uVs 16:20:00 Integrated Voltage Measurement... 16:20:09 Voltage Offset Correction: v_off_ini = 113.281 uV, v_off_fin = 127.845 uV 16:20:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.540 uVs 16:20:09 Integrated Voltage Measurement... 16:20:18 Voltage Offset Correction: v_off_ini = 133.053 uV, v_off_fin = 121.711 uV 16:20:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.318 uVs 16:20:18 Integrated Voltage Measurement... 16:20:27 Voltage Offset Correction: v_off_ini = 143.870 uV, v_off_fin = 124.805 uV 16:20:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.788 uVs 16:20:30 I2Y Average and RMS of Measurements VT = -214.018 +- 5.628 uVs I2Y = -19.690 +- 0.518 uTm^2 16:20:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:20:39 Integrated Voltage Measurement... 16:20:48 Voltage Offset Correction: v_off_ini = 132.041 uV, v_off_fin = 127.942 uV 16:20:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.079 uVs 16:20:48 Integrated Voltage Measurement... 16:20:57 Voltage Offset Correction: v_off_ini = 129.582 uV, v_off_fin = 133.295 uV 16:20:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.812 uVs 16:20:57 Integrated Voltage Measurement... 16:21:06 Voltage Offset Correction: v_off_ini = 130.879 uV, v_off_fin = 137.816 uV 16:21:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.764 uVs 16:21:06 Integrated Voltage Measurement... 16:21:15 Voltage Offset Correction: v_off_ini = 123.450 uV, v_off_fin = 134.044 uV 16:21:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.626 uVs 16:21:15 Integrated Voltage Measurement... 16:21:24 Voltage Offset Correction: v_off_ini = 121.609 uV, v_off_fin = 114.844 uV 16:21:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.279 uVs 16:21:24 Integrated Voltage Measurement... 16:21:33 Voltage Offset Correction: v_off_ini = 119.605 uV, v_off_fin = 122.700 uV 16:21:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.728 uVs 16:21:37 I1X Average and RMS of Measurements VT = -78.715 +- 6.060 uVs I1X = 15.743 +- 1.212 uTm 16:21:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:21:44 Integrated Voltage Measurement... 16:21:53 Voltage Offset Correction: v_off_ini = 148.221 uV, v_off_fin = 136.478 uV 16:21:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -256.474 uVs 16:21:53 Integrated Voltage Measurement... 16:22:02 Voltage Offset Correction: v_off_ini = 147.313 uV, v_off_fin = 134.549 uV 16:22:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.541 uVs 16:22:02 Integrated Voltage Measurement... 16:22:11 Voltage Offset Correction: v_off_ini = 135.111 uV, v_off_fin = 127.067 uV 16:22:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.575 uVs 16:22:11 Integrated Voltage Measurement... 16:22:20 Voltage Offset Correction: v_off_ini = 150.138 uV, v_off_fin = 146.345 uV 16:22:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.429 uVs 16:22:20 Integrated Voltage Measurement... 16:22:29 Voltage Offset Correction: v_off_ini = 130.527 uV, v_off_fin = 133.034 uV 16:22:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.602 uVs 16:22:29 Integrated Voltage Measurement... 16:22:38 Voltage Offset Correction: v_off_ini = 144.586 uV, v_off_fin = 153.722 uV 16:22:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.449 uVs 16:22:42 I1Y Average and RMS of Measurements VT = -239.678 +- 8.214 uVs I1Y = -47.936 +- 1.644 uTm 16:22:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:22:50 Integrated Voltage Measurement... 16:22:59 Voltage Offset Correction: v_off_ini = 136.796 uV, v_off_fin = 126.135 uV 16:22:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -71.087 uVs 16:22:59 Integrated Voltage Measurement... 16:23:08 Voltage Offset Correction: v_off_ini = 142.773 uV, v_off_fin = 142.490 uV 16:23:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.639 uVs 16:23:08 Integrated Voltage Measurement... 16:23:17 Voltage Offset Correction: v_off_ini = 145.504 uV, v_off_fin = 129.785 uV 16:23:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.721 uVs 16:23:17 Integrated Voltage Measurement... 16:23:26 Voltage Offset Correction: v_off_ini = 152.401 uV, v_off_fin = 142.942 uV 16:23:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.086 uVs 16:23:26 Integrated Voltage Measurement... 16:23:35 Voltage Offset Correction: v_off_ini = 141.185 uV, v_off_fin = 127.351 uV 16:23:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.212 uVs 16:23:35 Integrated Voltage Measurement... 16:23:44 Voltage Offset Correction: v_off_ini = 138.653 uV, v_off_fin = 141.214 uV 16:23:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.139 uVs 16:23:46 I2X Average and RMS of Measurements VT = -61.481 +- 2.544 uVs I2X = 5.656 +- 0.234 uTm^2 16:23:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:23:54 Integrated Voltage Measurement... 16:24:03 Voltage Offset Correction: v_off_ini = 131.789 uV, v_off_fin = 133.217 uV 16:24:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.782 uVs 16:24:03 Integrated Voltage Measurement... 16:24:12 Voltage Offset Correction: v_off_ini = 138.193 uV, v_off_fin = 143.734 uV 16:24:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.938 uVs 16:24:12 Integrated Voltage Measurement... 16:24:21 Voltage Offset Correction: v_off_ini = 131.940 uV, v_off_fin = 131.364 uV 16:24:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.041 uVs 16:24:21 Integrated Voltage Measurement... 16:24:30 Voltage Offset Correction: v_off_ini = 120.375 uV, v_off_fin = 139.154 uV 16:24:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.665 uVs 16:24:30 Integrated Voltage Measurement... 16:24:39 Voltage Offset Correction: v_off_ini = 127.074 uV, v_off_fin = 128.569 uV 16:24:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.359 uVs 16:24:39 Integrated Voltage Measurement... 16:24:48 Voltage Offset Correction: v_off_ini = 133.067 uV, v_off_fin = 112.171 uV 16:24:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.312 uVs 16:24:51 I2Y Average and RMS of Measurements VT = -214.183 +- 4.504 uVs I2Y = -19.705 +- 0.414 uTm^2 16:24:55 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:25:00 Integrated Voltage Measurement... 16:25:09 Voltage Offset Correction: v_off_ini = 125.635 uV, v_off_fin = 114.175 uV 16:25:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.490 uVs 16:25:09 Integrated Voltage Measurement... 16:25:18 Voltage Offset Correction: v_off_ini = 116.454 uV, v_off_fin = 130.601 uV 16:25:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.325 uVs 16:25:18 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = 147.753 uV, v_off_fin = 125.122 uV 16:25:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.194 uVs 16:25:27 Integrated Voltage Measurement... 16:25:36 Voltage Offset Correction: v_off_ini = 138.708 uV, v_off_fin = 140.655 uV 16:25:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.075 uVs 16:25:36 Integrated Voltage Measurement... 16:25:45 Voltage Offset Correction: v_off_ini = 116.635 uV, v_off_fin = 123.137 uV 16:25:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.451 uVs 16:25:45 Integrated Voltage Measurement... 16:25:54 Voltage Offset Correction: v_off_ini = 124.828 uV, v_off_fin = 141.141 uV 16:25:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.644 uVs 16:25:58 I1X Average and RMS of Measurements VT = -79.696 +- 4.195 uVs I1X = 15.940 +- 0.839 uTm 16:26:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:26:05 Integrated Voltage Measurement... 16:26:14 Voltage Offset Correction: v_off_ini = 117.399 uV, v_off_fin = 121.940 uV 16:26:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -235.073 uVs 16:26:14 Integrated Voltage Measurement... 16:26:23 Voltage Offset Correction: v_off_ini = 122.493 uV, v_off_fin = 129.852 uV 16:26:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.990 uVs 16:26:23 Integrated Voltage Measurement... 16:26:32 Voltage Offset Correction: v_off_ini = 122.756 uV, v_off_fin = 116.312 uV 16:26:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.821 uVs 16:26:32 Integrated Voltage Measurement... 16:26:41 Voltage Offset Correction: v_off_ini = 132.459 uV, v_off_fin = 130.699 uV 16:26:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.948 uVs 16:26:41 Integrated Voltage Measurement... 16:26:50 Voltage Offset Correction: v_off_ini = 126.665 uV, v_off_fin = 114.530 uV 16:26:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.477 uVs 16:26:50 Integrated Voltage Measurement... 16:26:59 Voltage Offset Correction: v_off_ini = 126.475 uV, v_off_fin = 134.141 uV 16:26:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.658 uVs 16:27:03 I1Y Average and RMS of Measurements VT = -229.661 +- 2.700 uVs I1Y = -45.933 +- 0.540 uTm 16:27:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:27:11 Integrated Voltage Measurement... 16:27:20 Voltage Offset Correction: v_off_ini = 129.111 uV, v_off_fin = 116.301 uV 16:27:20 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -75.983 uVs 16:27:20 Integrated Voltage Measurement... 16:27:29 Voltage Offset Correction: v_off_ini = 139.340 uV, v_off_fin = 138.048 uV 16:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.960 uVs 16:27:29 Integrated Voltage Measurement... 16:27:38 Voltage Offset Correction: v_off_ini = 130.309 uV, v_off_fin = 123.779 uV 16:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.294 uVs 16:27:38 Integrated Voltage Measurement... 16:27:47 Voltage Offset Correction: v_off_ini = 137.791 uV, v_off_fin = 138.222 uV 16:27:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.410 uVs 16:27:47 Integrated Voltage Measurement... 16:27:56 Voltage Offset Correction: v_off_ini = 139.760 uV, v_off_fin = 134.434 uV 16:27:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.335 uVs 16:27:56 Integrated Voltage Measurement... 16:28:05 Voltage Offset Correction: v_off_ini = 128.515 uV, v_off_fin = 147.543 uV 16:28:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.315 uVs 16:28:07 I2X Average and RMS of Measurements VT = -73.549 +- 6.505 uVs I2X = 6.766 +- 0.598 uTm^2 16:28:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:28:15 Integrated Voltage Measurement... 16:28:24 Voltage Offset Correction: v_off_ini = 135.150 uV, v_off_fin = 133.026 uV 16:28:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.409 uVs 16:28:24 Integrated Voltage Measurement... 16:28:33 Voltage Offset Correction: v_off_ini = 144.667 uV, v_off_fin = 137.102 uV 16:28:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.408 uVs 16:28:33 Integrated Voltage Measurement... 16:28:42 Voltage Offset Correction: v_off_ini = 144.044 uV, v_off_fin = 135.602 uV 16:28:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.990 uVs 16:28:42 Integrated Voltage Measurement... 16:28:51 Voltage Offset Correction: v_off_ini = 127.853 uV, v_off_fin = 128.949 uV 16:28:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.519 uVs 16:28:51 Integrated Voltage Measurement... 16:29:00 Voltage Offset Correction: v_off_ini = 145.880 uV, v_off_fin = 137.965 uV 16:29:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.984 uVs 16:29:00 Integrated Voltage Measurement... 16:29:09 Voltage Offset Correction: v_off_ini = 133.757 uV, v_off_fin = 131.541 uV 16:29:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.708 uVs 16:29:11 I2Y Average and RMS of Measurements VT = -208.003 +- 15.565 uVs I2Y = -19.136 +- 1.432 uTm^2 16:29:19 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:29:23 Integrated Voltage Measurement... 16:29:32 Voltage Offset Correction: v_off_ini = 128.976 uV, v_off_fin = 118.596 uV 16:29:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -60.581 uVs 16:29:32 Integrated Voltage Measurement... 16:29:41 Voltage Offset Correction: v_off_ini = 124.508 uV, v_off_fin = 137.271 uV 16:29:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 57.362 uVs 16:29:41 Integrated Voltage Measurement... 16:29:50 Voltage Offset Correction: v_off_ini = 126.187 uV, v_off_fin = 124.933 uV 16:29:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.895 uVs 16:29:50 Integrated Voltage Measurement... 16:29:59 Voltage Offset Correction: v_off_ini = 127.680 uV, v_off_fin = 124.945 uV 16:29:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.506 uVs 16:30:00 Integrated Voltage Measurement... 16:30:08 Voltage Offset Correction: v_off_ini = 116.038 uV, v_off_fin = 124.390 uV 16:30:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.239 uVs 16:30:09 Integrated Voltage Measurement... 16:30:17 Voltage Offset Correction: v_off_ini = 118.946 uV, v_off_fin = 116.283 uV 16:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.208 uVs 16:30:22 I1X Average and RMS of Measurements VT = -60.965 +- 2.643 uVs I1X = 12.194 +- 0.528 uTm 16:30:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:30:28 Integrated Voltage Measurement... 16:30:37 Voltage Offset Correction: v_off_ini = 111.463 uV, v_off_fin = 99.368 uV 16:30:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.159 uVs 16:30:38 Integrated Voltage Measurement... 16:30:46 Voltage Offset Correction: v_off_ini = 115.710 uV, v_off_fin = 147.039 uV 16:30:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.028 uVs 16:30:47 Integrated Voltage Measurement... 16:30:55 Voltage Offset Correction: v_off_ini = 120.946 uV, v_off_fin = 96.517 uV 16:30:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.327 uVs 16:30:56 Integrated Voltage Measurement... 16:31:04 Voltage Offset Correction: v_off_ini = 111.715 uV, v_off_fin = 133.993 uV 16:31:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.958 uVs 16:31:05 Integrated Voltage Measurement... 16:31:13 Voltage Offset Correction: v_off_ini = 108.230 uV, v_off_fin = 108.024 uV 16:31:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.967 uVs 16:31:14 Integrated Voltage Measurement... 16:31:22 Voltage Offset Correction: v_off_ini = 126.873 uV, v_off_fin = 131.183 uV 16:31:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.317 uVs 16:31:27 I1Y Average and RMS of Measurements VT = -236.126 +- 2.473 uVs I1Y = -47.225 +- 0.495 uTm 16:31:29 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:31:32 Integrated Voltage Measurement... 16:31:41 Voltage Offset Correction: v_off_ini = 110.389 uV, v_off_fin = 114.396 uV 16:31:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.429 uVs 16:31:41 Integrated Voltage Measurement... 16:31:50 Voltage Offset Correction: v_off_ini = 123.170 uV, v_off_fin = 139.573 uV 16:31:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 18.516 uVs 16:31:50 Integrated Voltage Measurement... 16:31:59 Voltage Offset Correction: v_off_ini = 117.296 uV, v_off_fin = 117.796 uV 16:31:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.921 uVs 16:31:59 Integrated Voltage Measurement... 16:32:08 Voltage Offset Correction: v_off_ini = 123.808 uV, v_off_fin = 117.926 uV 16:32:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.372 uVs 16:32:08 Integrated Voltage Measurement... 16:32:17 Voltage Offset Correction: v_off_ini = 105.808 uV, v_off_fin = 109.378 uV 16:32:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.014 uVs 16:32:17 Integrated Voltage Measurement... 16:32:26 Voltage Offset Correction: v_off_ini = 128.610 uV, v_off_fin = 145.682 uV 16:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.050 uVs 16:32:28 I2X Average and RMS of Measurements VT = -38.884 +- 10.008 uVs I2X = 3.577 +- 0.921 uTm^2 16:32:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:32:34 Integrated Voltage Measurement... 16:32:43 Voltage Offset Correction: v_off_ini = 132.324 uV, v_off_fin = 118.063 uV 16:32:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.247 uVs 16:32:43 Integrated Voltage Measurement... 16:32:52 Voltage Offset Correction: v_off_ini = 134.732 uV, v_off_fin = 124.606 uV 16:32:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.597 uVs 16:32:52 Integrated Voltage Measurement... 16:33:01 Voltage Offset Correction: v_off_ini = 115.327 uV, v_off_fin = 120.416 uV 16:33:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.168 uVs 16:33:01 Integrated Voltage Measurement... 16:33:10 Voltage Offset Correction: v_off_ini = 118.310 uV, v_off_fin = 115.194 uV 16:33:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.306 uVs 16:33:10 Integrated Voltage Measurement... 16:33:19 Voltage Offset Correction: v_off_ini = 110.481 uV, v_off_fin = 116.311 uV 16:33:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.950 uVs 16:33:19 Integrated Voltage Measurement... 16:33:28 Voltage Offset Correction: v_off_ini = 106.632 uV, v_off_fin = 122.059 uV 16:33:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.135 uVs 16:33:30 I2Y Average and RMS of Measurements VT = -212.400 +- 4.777 uVs I2Y = -19.541 +- 0.439 uTm^2 16:33:34 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:33:39 Integrated Voltage Measurement... 16:33:48 Voltage Offset Correction: v_off_ini = 145.495 uV, v_off_fin = 141.889 uV 16:33:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -93.127 uVs 16:33:48 Integrated Voltage Measurement... 16:33:57 Voltage Offset Correction: v_off_ini = 128.461 uV, v_off_fin = 142.409 uV 16:33:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.706 uVs 16:33:57 Integrated Voltage Measurement... 16:34:06 Voltage Offset Correction: v_off_ini = 129.648 uV, v_off_fin = 140.305 uV 16:34:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.824 uVs 16:34:06 Integrated Voltage Measurement... 16:34:15 Voltage Offset Correction: v_off_ini = 135.212 uV, v_off_fin = 142.994 uV 16:34:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.778 uVs 16:34:15 Integrated Voltage Measurement... 16:34:24 Voltage Offset Correction: v_off_ini = 118.214 uV, v_off_fin = 117.565 uV 16:34:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.164 uVs 16:34:24 Integrated Voltage Measurement... 16:34:33 Voltage Offset Correction: v_off_ini = 142.263 uV, v_off_fin = 145.384 uV 16:34:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.114 uVs 16:34:37 I1X Average and RMS of Measurements VT = -70.119 +- 8.279 uVs I1X = 14.024 +- 1.656 uTm 16:34:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:34:44 Integrated Voltage Measurement... 16:34:53 Voltage Offset Correction: v_off_ini = 160.126 uV, v_off_fin = 151.914 uV 16:34:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.685 uVs 16:34:53 Integrated Voltage Measurement... 16:35:02 Voltage Offset Correction: v_off_ini = 144.143 uV, v_off_fin = 150.263 uV 16:35:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.769 uVs 16:35:02 Integrated Voltage Measurement... 16:35:11 Voltage Offset Correction: v_off_ini = 141.272 uV, v_off_fin = 137.595 uV 16:35:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.905 uVs 16:35:11 Integrated Voltage Measurement... 16:35:20 Voltage Offset Correction: v_off_ini = 150.945 uV, v_off_fin = 152.214 uV 16:35:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.520 uVs 16:35:20 Integrated Voltage Measurement... 16:35:29 Voltage Offset Correction: v_off_ini = 140.038 uV, v_off_fin = 134.144 uV 16:35:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.853 uVs 16:35:29 Integrated Voltage Measurement... 16:35:38 Voltage Offset Correction: v_off_ini = 153.067 uV, v_off_fin = 166.111 uV 16:35:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.386 uVs 16:35:42 I1Y Average and RMS of Measurements VT = -249.020 +- 7.408 uVs I1Y = -49.804 +- 1.482 uTm 16:35:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:35:47 Integrated Voltage Measurement... 16:35:56 Voltage Offset Correction: v_off_ini = 131.977 uV, v_off_fin = 125.692 uV 16:35:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.262 uVs 16:35:56 Integrated Voltage Measurement... 16:36:05 Voltage Offset Correction: v_off_ini = 134.732 uV, v_off_fin = 160.335 uV 16:36:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.435 uVs 16:36:05 Integrated Voltage Measurement... 16:36:14 Voltage Offset Correction: v_off_ini = 160.290 uV, v_off_fin = 144.003 uV 16:36:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.772 uVs 16:36:14 Integrated Voltage Measurement... 16:36:23 Voltage Offset Correction: v_off_ini = 165.814 uV, v_off_fin = 180.392 uV 16:36:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.005 uVs 16:36:23 Integrated Voltage Measurement... 16:36:32 Voltage Offset Correction: v_off_ini = 154.862 uV, v_off_fin = 147.669 uV 16:36:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.865 uVs 16:36:32 Integrated Voltage Measurement... 16:36:41 Voltage Offset Correction: v_off_ini = 149.926 uV, v_off_fin = 154.609 uV 16:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.712 uVs 16:36:44 I2X Average and RMS of Measurements VT = -47.842 +- 5.388 uVs I2X = 4.401 +- 0.496 uTm^2 16:36:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:36:49 Integrated Voltage Measurement... 16:36:58 Voltage Offset Correction: v_off_ini = 147.342 uV, v_off_fin = 152.445 uV 16:36:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.422 uVs 16:36:58 Integrated Voltage Measurement... 16:37:07 Voltage Offset Correction: v_off_ini = 153.378 uV, v_off_fin = 163.882 uV 16:37:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.663 uVs 16:37:07 Integrated Voltage Measurement... 16:37:16 Voltage Offset Correction: v_off_ini = 157.737 uV, v_off_fin = 149.341 uV 16:37:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.111 uVs 16:37:16 Integrated Voltage Measurement... 16:37:25 Voltage Offset Correction: v_off_ini = 152.593 uV, v_off_fin = 148.507 uV 16:37:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.221 uVs 16:37:25 Integrated Voltage Measurement... 16:37:34 Voltage Offset Correction: v_off_ini = 158.727 uV, v_off_fin = 160.297 uV 16:37:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.497 uVs 16:37:34 Integrated Voltage Measurement... 16:37:43 Voltage Offset Correction: v_off_ini = 174.803 uV, v_off_fin = 173.035 uV 16:37:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.774 uVs 16:37:45 I2Y Average and RMS of Measurements VT = -218.448 +- 6.893 uVs I2Y = -20.097 +- 0.634 uTm^2 16:37:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:37:54 Integrated Voltage Measurement... 16:38:03 Voltage Offset Correction: v_off_ini = 159.925 uV, v_off_fin = 152.854 uV 16:38:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -70.653 uVs 16:38:03 Integrated Voltage Measurement... 16:38:12 Voltage Offset Correction: v_off_ini = 145.388 uV, v_off_fin = 141.101 uV 16:38:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 59.134 uVs 16:38:12 Integrated Voltage Measurement... 16:38:21 Voltage Offset Correction: v_off_ini = 135.855 uV, v_off_fin = 143.627 uV 16:38:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.697 uVs 16:38:21 Integrated Voltage Measurement... 16:38:30 Voltage Offset Correction: v_off_ini = 157.431 uV, v_off_fin = 148.619 uV 16:38:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.231 uVs 16:38:30 Integrated Voltage Measurement... 16:38:39 Voltage Offset Correction: v_off_ini = 145.115 uV, v_off_fin = 151.549 uV 16:38:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.299 uVs 16:38:39 Integrated Voltage Measurement... 16:38:48 Voltage Offset Correction: v_off_ini = 147.267 uV, v_off_fin = 150.185 uV 16:38:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.952 uVs 16:38:52 I1X Average and RMS of Measurements VT = -73.161 +- 5.871 uVs I1X = 14.633 +- 1.173 uTm 16:38:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:38:59 Integrated Voltage Measurement... 16:39:08 Voltage Offset Correction: v_off_ini = 152.182 uV, v_off_fin = 145.794 uV 16:39:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.933 uVs 16:39:08 Integrated Voltage Measurement... 16:39:17 Voltage Offset Correction: v_off_ini = 152.120 uV, v_off_fin = 164.819 uV 16:39:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.800 uVs 16:39:17 Integrated Voltage Measurement... 16:39:26 Voltage Offset Correction: v_off_ini = 151.058 uV, v_off_fin = 141.998 uV 16:39:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.396 uVs 16:39:26 Integrated Voltage Measurement... 16:39:35 Voltage Offset Correction: v_off_ini = 145.298 uV, v_off_fin = 163.343 uV 16:39:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.484 uVs 16:39:35 Integrated Voltage Measurement... 16:39:44 Voltage Offset Correction: v_off_ini = 157.848 uV, v_off_fin = 156.241 uV 16:39:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.879 uVs 16:39:44 Integrated Voltage Measurement... 16:39:53 Voltage Offset Correction: v_off_ini = 168.017 uV, v_off_fin = 173.987 uV 16:39:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.492 uVs 16:39:57 I1Y Average and RMS of Measurements VT = -249.497 +- 2.552 uVs I1Y = -49.899 +- 0.510 uTm 16:40:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:40:02 Integrated Voltage Measurement... 16:40:11 Voltage Offset Correction: v_off_ini = 171.573 uV, v_off_fin = 152.637 uV 16:40:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.101 uVs 16:40:11 Integrated Voltage Measurement... 16:40:20 Voltage Offset Correction: v_off_ini = 143.141 uV, v_off_fin = 156.518 uV 16:40:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.267 uVs 16:40:20 Integrated Voltage Measurement... 16:40:29 Voltage Offset Correction: v_off_ini = 144.704 uV, v_off_fin = 147.959 uV 16:40:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.113 uVs 16:40:29 Integrated Voltage Measurement... 16:40:38 Voltage Offset Correction: v_off_ini = 162.185 uV, v_off_fin = 165.217 uV 16:40:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.160 uVs 16:40:38 Integrated Voltage Measurement... 16:40:47 Voltage Offset Correction: v_off_ini = 158.706 uV, v_off_fin = 146.504 uV 16:40:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.967 uVs 16:40:47 Integrated Voltage Measurement... 16:40:56 Voltage Offset Correction: v_off_ini = 153.270 uV, v_off_fin = 161.579 uV 16:40:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.061 uVs 16:40:59 I2X Average and RMS of Measurements VT = -66.112 +- 5.027 uVs I2X = 6.082 +- 0.463 uTm^2 16:41:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:41:04 Integrated Voltage Measurement... 16:41:13 Voltage Offset Correction: v_off_ini = 156.992 uV, v_off_fin = 141.419 uV 16:41:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.324 uVs 16:41:13 Integrated Voltage Measurement... 16:41:22 Voltage Offset Correction: v_off_ini = 155.335 uV, v_off_fin = 152.521 uV 16:41:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.490 uVs 16:41:22 Integrated Voltage Measurement... 16:41:31 Voltage Offset Correction: v_off_ini = 150.717 uV, v_off_fin = 141.923 uV 16:41:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.219 uVs 16:41:31 Integrated Voltage Measurement... 16:41:40 Voltage Offset Correction: v_off_ini = 144.928 uV, v_off_fin = 136.672 uV 16:41:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.792 uVs 16:41:40 Integrated Voltage Measurement... 16:41:49 Voltage Offset Correction: v_off_ini = 145.213 uV, v_off_fin = 131.746 uV 16:41:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.158 uVs 16:41:49 Integrated Voltage Measurement... 16:41:58 Voltage Offset Correction: v_off_ini = 136.438 uV, v_off_fin = 133.949 uV 16:41:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.944 uVs 16:42:00 I2Y Average and RMS of Measurements VT = -221.655 +- 8.462 uVs I2Y = -20.392 +- 0.779 uTm^2 16:42:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:42:09 Integrated Voltage Measurement... 16:42:18 Voltage Offset Correction: v_off_ini = 133.094 uV, v_off_fin = 130.198 uV 16:42:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.580 uVs 16:42:18 Integrated Voltage Measurement... 16:42:27 Voltage Offset Correction: v_off_ini = 124.478 uV, v_off_fin = 133.779 uV 16:42:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.528 uVs 16:42:27 Integrated Voltage Measurement... 16:42:36 Voltage Offset Correction: v_off_ini = 129.135 uV, v_off_fin = 130.064 uV 16:42:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.358 uVs 16:42:36 Integrated Voltage Measurement... 16:42:45 Voltage Offset Correction: v_off_ini = 134.708 uV, v_off_fin = 125.760 uV 16:42:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.515 uVs 16:42:45 Integrated Voltage Measurement... 16:42:54 Voltage Offset Correction: v_off_ini = 132.464 uV, v_off_fin = 133.683 uV 16:42:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.072 uVs 16:42:54 Integrated Voltage Measurement... 16:43:03 Voltage Offset Correction: v_off_ini = 118.411 uV, v_off_fin = 127.489 uV 16:43:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.213 uVs 16:43:07 I1X Average and RMS of Measurements VT = -85.878 +- 2.086 uVs I1X = 17.176 +- 0.417 uTm 16:43:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:43:14 Integrated Voltage Measurement... 16:43:23 Voltage Offset Correction: v_off_ini = 120.355 uV, v_off_fin = 102.737 uV 16:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.241 uVs 16:43:23 Integrated Voltage Measurement... 16:43:32 Voltage Offset Correction: v_off_ini = 118.069 uV, v_off_fin = 142.748 uV 16:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.166 uVs 16:43:32 Integrated Voltage Measurement... 16:43:41 Voltage Offset Correction: v_off_ini = 119.826 uV, v_off_fin = 114.557 uV 16:43:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.911 uVs 16:43:41 Integrated Voltage Measurement... 16:43:50 Voltage Offset Correction: v_off_ini = 124.159 uV, v_off_fin = 130.008 uV 16:43:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.494 uVs 16:43:50 Integrated Voltage Measurement... 16:43:59 Voltage Offset Correction: v_off_ini = 131.497 uV, v_off_fin = 124.660 uV 16:43:59 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.546 uVs 16:43:59 Integrated Voltage Measurement... 16:44:08 Voltage Offset Correction: v_off_ini = 124.749 uV, v_off_fin = 141.310 uV 16:44:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.915 uVs 16:44:12 I1Y Average and RMS of Measurements VT = -248.712 +- 7.093 uVs I1Y = -49.743 +- 1.420 uTm 16:44:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:44:17 Integrated Voltage Measurement... 16:44:26 Voltage Offset Correction: v_off_ini = 121.311 uV, v_off_fin = 115.622 uV 16:44:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.971 uVs 16:44:26 Integrated Voltage Measurement... 16:44:35 Voltage Offset Correction: v_off_ini = 118.287 uV, v_off_fin = 119.015 uV 16:44:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.646 uVs 16:44:35 Integrated Voltage Measurement... 16:44:44 Voltage Offset Correction: v_off_ini = 115.193 uV, v_off_fin = 110.816 uV 16:44:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.367 uVs 16:44:44 Integrated Voltage Measurement... 16:44:53 Voltage Offset Correction: v_off_ini = 110.816 uV, v_off_fin = 123.207 uV 16:44:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.218 uVs 16:44:53 Integrated Voltage Measurement... 16:45:02 Voltage Offset Correction: v_off_ini = 120.271 uV, v_off_fin = 118.984 uV 16:45:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.009 uVs 16:45:02 Integrated Voltage Measurement... 16:45:11 Voltage Offset Correction: v_off_ini = 117.580 uV, v_off_fin = 125.977 uV 16:45:11 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 63.195 uVs 16:45:14 I2X Average and RMS of Measurements VT = -62.068 +- 1.423 uVs I2X = 5.710 +- 0.131 uTm^2 16:45:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:45:19 Integrated Voltage Measurement... 16:45:28 Voltage Offset Correction: v_off_ini = 110.610 uV, v_off_fin = 108.411 uV 16:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.590 uVs 16:45:28 Integrated Voltage Measurement... 16:45:37 Voltage Offset Correction: v_off_ini = 117.835 uV, v_off_fin = 122.344 uV 16:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.749 uVs 16:45:37 Integrated Voltage Measurement... 16:45:46 Voltage Offset Correction: v_off_ini = 129.279 uV, v_off_fin = 120.405 uV 16:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.490 uVs 16:45:46 Integrated Voltage Measurement... 16:45:55 Voltage Offset Correction: v_off_ini = 122.299 uV, v_off_fin = 113.301 uV 16:45:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.721 uVs 16:45:55 Integrated Voltage Measurement... 16:46:04 Voltage Offset Correction: v_off_ini = 110.752 uV, v_off_fin = 113.005 uV 16:46:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.776 uVs 16:46:04 Integrated Voltage Measurement... 16:46:13 Voltage Offset Correction: v_off_ini = 108.680 uV, v_off_fin = 116.692 uV 16:46:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.864 uVs 16:46:16 I2Y Average and RMS of Measurements VT = -224.865 +- 1.202 uVs I2Y = -20.688 +- 0.111 uTm^2 16:46:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:46:24 Integrated Voltage Measurement... 16:46:33 Voltage Offset Correction: v_off_ini = 118.104 uV, v_off_fin = 120.934 uV 16:46:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.152 uVs 16:46:33 Integrated Voltage Measurement... 16:46:42 Voltage Offset Correction: v_off_ini = 126.756 uV, v_off_fin = 133.976 uV 16:46:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.419 uVs 16:46:42 Integrated Voltage Measurement... 16:46:51 Voltage Offset Correction: v_off_ini = 126.677 uV, v_off_fin = 125.846 uV 16:46:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.420 uVs 16:46:51 Integrated Voltage Measurement... 16:47:00 Voltage Offset Correction: v_off_ini = 123.491 uV, v_off_fin = 130.893 uV 16:47:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.824 uVs 16:47:00 Integrated Voltage Measurement... 16:47:09 Voltage Offset Correction: v_off_ini = 122.893 uV, v_off_fin = 119.391 uV 16:47:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.606 uVs 16:47:09 Integrated Voltage Measurement... 16:47:18 Voltage Offset Correction: v_off_ini = 150.969 uV, v_off_fin = 142.953 uV 16:47:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.550 uVs 16:47:22 I1X Average and RMS of Measurements VT = -76.162 +- 4.578 uVs I1X = 15.233 +- 0.916 uTm 16:47:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:47:29 Integrated Voltage Measurement... 16:47:38 Voltage Offset Correction: v_off_ini = 117.214 uV, v_off_fin = 116.022 uV 16:47:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.769 uVs 16:47:38 Integrated Voltage Measurement... 16:47:47 Voltage Offset Correction: v_off_ini = 124.654 uV, v_off_fin = 135.856 uV 16:47:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 252.225 uVs 16:47:47 Integrated Voltage Measurement... 16:47:56 Voltage Offset Correction: v_off_ini = 113.510 uV, v_off_fin = 103.829 uV 16:47:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -239.145 uVs 16:47:56 Integrated Voltage Measurement... 16:48:05 Voltage Offset Correction: v_off_ini = 109.097 uV, v_off_fin = 138.069 uV 16:48:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 265.971 uVs 16:48:05 Integrated Voltage Measurement... 16:48:14 Voltage Offset Correction: v_off_ini = 120.152 uV, v_off_fin = 101.951 uV 16:48:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -243.865 uVs 16:48:14 Integrated Voltage Measurement... 16:48:23 Voltage Offset Correction: v_off_ini = 121.004 uV, v_off_fin = 137.082 uV 16:48:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 250.972 uVs 16:48:27 I1Y Average and RMS of Measurements VT = -252.825 +- 4.527 uVs I1Y = -50.562 +- 0.908 uTm 16:48:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:48:32 Integrated Voltage Measurement... 16:48:41 Voltage Offset Correction: v_off_ini = 121.905 uV, v_off_fin = 115.457 uV 16:48:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -68.097 uVs 16:48:41 Integrated Voltage Measurement... 16:48:50 Voltage Offset Correction: v_off_ini = 125.805 uV, v_off_fin = 115.544 uV 16:48:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 34.638 uVs 16:48:50 Integrated Voltage Measurement... 16:48:59 Voltage Offset Correction: v_off_ini = 123.802 uV, v_off_fin = 117.112 uV 16:48:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -64.421 uVs 16:48:59 Integrated Voltage Measurement... 16:49:08 Voltage Offset Correction: v_off_ini = 123.757 uV, v_off_fin = 129.032 uV 16:49:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.243 uVs 16:49:08 Integrated Voltage Measurement... 16:49:17 Voltage Offset Correction: v_off_ini = 137.059 uV, v_off_fin = 126.184 uV 16:49:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.105 uVs 16:49:17 Integrated Voltage Measurement... 16:49:26 Voltage Offset Correction: v_off_ini = 124.197 uV, v_off_fin = 125.369 uV 16:49:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.432 uVs 16:49:29 I2X Average and RMS of Measurements VT = -62.489 +- 9.859 uVs I2X = 5.749 +- 0.907 uTm^2 16:49:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:49:34 Integrated Voltage Measurement... 16:49:43 Voltage Offset Correction: v_off_ini = 109.235 uV, v_off_fin = 109.214 uV 16:49:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.647 uVs 16:49:43 Integrated Voltage Measurement... 16:49:52 Voltage Offset Correction: v_off_ini = 114.181 uV, v_off_fin = 106.296 uV 16:49:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.879 uVs 16:49:52 Integrated Voltage Measurement... 16:50:01 Voltage Offset Correction: v_off_ini = 104.170 uV, v_off_fin = 106.848 uV 16:50:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.197 uVs 16:50:01 Integrated Voltage Measurement... 16:50:10 Voltage Offset Correction: v_off_ini = 122.453 uV, v_off_fin = 115.443 uV 16:50:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.293 uVs 16:50:10 Integrated Voltage Measurement... 16:50:19 Voltage Offset Correction: v_off_ini = 122.094 uV, v_off_fin = 115.236 uV 16:50:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.613 uVs 16:50:19 Integrated Voltage Measurement... 16:50:28 Voltage Offset Correction: v_off_ini = 124.669 uV, v_off_fin = 118.519 uV 16:50:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.108 uVs 16:50:30 I2Y Average and RMS of Measurements VT = -230.456 +- 5.756 uVs I2Y = -21.202 +- 0.530 uTm^2 16:50:47 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:50:51 Integrated Voltage Measurement... 16:51:00 Voltage Offset Correction: v_off_ini = 142.155 uV, v_off_fin = 131.348 uV 16:51:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -58.720 uVs 16:51:00 Integrated Voltage Measurement... 16:51:09 Voltage Offset Correction: v_off_ini = 128.018 uV, v_off_fin = 130.646 uV 16:51:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.904 uVs 16:51:09 Integrated Voltage Measurement... 16:51:18 Voltage Offset Correction: v_off_ini = 135.243 uV, v_off_fin = 122.262 uV 16:51:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.869 uVs 16:51:18 Integrated Voltage Measurement... 16:51:27 Voltage Offset Correction: v_off_ini = 139.198 uV, v_off_fin = 136.793 uV 16:51:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.887 uVs 16:51:27 Integrated Voltage Measurement... 16:51:36 Voltage Offset Correction: v_off_ini = 129.240 uV, v_off_fin = 121.226 uV 16:51:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.331 uVs 16:51:36 Integrated Voltage Measurement... 16:51:45 Voltage Offset Correction: v_off_ini = 124.089 uV, v_off_fin = 123.663 uV 16:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.223 uVs 16:51:50 I1X Average and RMS of Measurements VT = -52.489 +- 4.345 uVs I1X = 10.498 +- 0.869 uTm 16:51:52 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:51:56 Integrated Voltage Measurement... 16:52:05 Voltage Offset Correction: v_off_ini = 123.780 uV, v_off_fin = 116.316 uV 16:52:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -289.180 uVs 16:52:05 Integrated Voltage Measurement... 16:52:14 Voltage Offset Correction: v_off_ini = 132.676 uV, v_off_fin = 142.809 uV 16:52:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 302.445 uVs 16:52:14 Integrated Voltage Measurement... 16:52:23 Voltage Offset Correction: v_off_ini = 129.525 uV, v_off_fin = 117.624 uV 16:52:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -298.080 uVs 16:52:23 Integrated Voltage Measurement... 16:52:32 Voltage Offset Correction: v_off_ini = 121.404 uV, v_off_fin = 143.965 uV 16:52:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 300.306 uVs 16:52:32 Integrated Voltage Measurement... 16:52:41 Voltage Offset Correction: v_off_ini = 132.660 uV, v_off_fin = 107.772 uV 16:52:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -306.196 uVs 16:52:41 Integrated Voltage Measurement... 16:52:50 Voltage Offset Correction: v_off_ini = 122.626 uV, v_off_fin = 128.708 uV 16:52:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 286.667 uVs 16:52:55 I1Y Average and RMS of Measurements VT = -297.146 +- 1.470 uVs I1Y = -59.429 +- 0.294 uTm 16:53:00 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:53:02 Integrated Voltage Measurement... 16:53:11 Voltage Offset Correction: v_off_ini = 120.296 uV, v_off_fin = 116.038 uV 16:53:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.490 uVs 16:53:11 Integrated Voltage Measurement... 16:53:20 Voltage Offset Correction: v_off_ini = 126.385 uV, v_off_fin = 157.884 uV 16:53:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 17.989 uVs 16:53:20 Integrated Voltage Measurement... 16:53:29 Voltage Offset Correction: v_off_ini = 127.397 uV, v_off_fin = 115.226 uV 16:53:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.811 uVs 16:53:29 Integrated Voltage Measurement... 16:53:38 Voltage Offset Correction: v_off_ini = 124.883 uV, v_off_fin = 133.172 uV 16:53:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 38.401 uVs 16:53:38 Integrated Voltage Measurement... 16:53:47 Voltage Offset Correction: v_off_ini = 116.416 uV, v_off_fin = 117.355 uV 16:53:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.044 uVs 16:53:47 Integrated Voltage Measurement... 16:53:56 Voltage Offset Correction: v_off_ini = 118.480 uV, v_off_fin = 130.243 uV 16:53:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 26.607 uVs 16:53:59 I2X Average and RMS of Measurements VT = -22.890 +- 8.316 uVs I2X = 2.106 +- 0.765 uTm^2 16:54:04 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:54:06 Integrated Voltage Measurement... 16:54:15 Voltage Offset Correction: v_off_ini = 122.827 uV, v_off_fin = 118.295 uV 16:54:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.529 uVs 16:54:15 Integrated Voltage Measurement... 16:54:24 Voltage Offset Correction: v_off_ini = 119.689 uV, v_off_fin = 113.692 uV 16:54:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.762 uVs 16:54:24 Integrated Voltage Measurement... 16:54:33 Voltage Offset Correction: v_off_ini = 134.339 uV, v_off_fin = 143.431 uV 16:54:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.812 uVs 16:54:33 Integrated Voltage Measurement... 16:54:42 Voltage Offset Correction: v_off_ini = 134.544 uV, v_off_fin = 113.361 uV 16:54:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.365 uVs 16:54:43 Integrated Voltage Measurement... 16:54:51 Voltage Offset Correction: v_off_ini = 111.927 uV, v_off_fin = 99.431 uV 16:54:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.278 uVs 16:54:52 Integrated Voltage Measurement... 16:55:00 Voltage Offset Correction: v_off_ini = 107.708 uV, v_off_fin = 105.155 uV 16:55:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.929 uVs 16:55:03 I2Y Average and RMS of Measurements VT = -261.446 +- 8.366 uVs I2Y = -24.053 +- 0.770 uTm^2 16:55:08 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:55:12 Integrated Voltage Measurement... 16:55:21 Voltage Offset Correction: v_off_ini = 86.309 uV, v_off_fin = 90.726 uV 16:55:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -39.161 uVs 16:55:21 Integrated Voltage Measurement... 16:55:30 Voltage Offset Correction: v_off_ini = 98.100 uV, v_off_fin = 107.444 uV 16:55:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.974 uVs 16:55:30 Integrated Voltage Measurement... 16:55:39 Voltage Offset Correction: v_off_ini = 90.701 uV, v_off_fin = 98.267 uV 16:55:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.844 uVs 16:55:39 Integrated Voltage Measurement... 16:55:48 Voltage Offset Correction: v_off_ini = 100.181 uV, v_off_fin = 101.088 uV 16:55:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.832 uVs 16:55:48 Integrated Voltage Measurement... 16:55:57 Voltage Offset Correction: v_off_ini = 103.932 uV, v_off_fin = 103.030 uV 16:55:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.980 uVs 16:55:57 Integrated Voltage Measurement... 16:56:06 Voltage Offset Correction: v_off_ini = 105.850 uV, v_off_fin = 112.587 uV 16:56:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.559 uVs 16:56:10 I1X Average and RMS of Measurements VT = -49.392 +- 6.619 uVs I1X = 9.878 +- 1.324 uTm 16:56:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:56:17 Integrated Voltage Measurement... 16:56:26 Voltage Offset Correction: v_off_ini = 96.691 uV, v_off_fin = 82.791 uV 16:56:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.890 uVs 16:56:26 Integrated Voltage Measurement... 16:56:35 Voltage Offset Correction: v_off_ini = 79.748 uV, v_off_fin = 94.898 uV 16:56:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 308.224 uVs 16:56:35 Integrated Voltage Measurement... 16:56:44 Voltage Offset Correction: v_off_ini = 83.267 uV, v_off_fin = 77.474 uV 16:56:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.664 uVs 16:56:44 Integrated Voltage Measurement... 16:56:53 Voltage Offset Correction: v_off_ini = 93.901 uV, v_off_fin = 104.010 uV 16:56:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.272 uVs 16:56:53 Integrated Voltage Measurement... 16:57:02 Voltage Offset Correction: v_off_ini = 118.044 uV, v_off_fin = 108.285 uV 16:57:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.227 uVs 16:57:02 Integrated Voltage Measurement... 16:57:11 Voltage Offset Correction: v_off_ini = 140.267 uV, v_off_fin = 137.688 uV 16:57:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.921 uVs 16:57:15 I1Y Average and RMS of Measurements VT = -287.200 +- 6.912 uVs I1Y = -57.440 +- 1.382 uTm 16:57:20 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:57:23 Integrated Voltage Measurement... 16:57:32 Voltage Offset Correction: v_off_ini = 118.061 uV, v_off_fin = 104.768 uV 16:57:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.874 uVs 16:57:32 Integrated Voltage Measurement... 16:57:41 Voltage Offset Correction: v_off_ini = 108.069 uV, v_off_fin = 124.950 uV 16:57:41 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 31.330 uVs 16:57:41 Integrated Voltage Measurement... 16:57:50 Voltage Offset Correction: v_off_ini = 109.257 uV, v_off_fin = 105.981 uV 16:57:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.301 uVs 16:57:50 Integrated Voltage Measurement... 16:57:59 Voltage Offset Correction: v_off_ini = 119.293 uV, v_off_fin = 126.254 uV 16:57:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.017 uVs 16:57:59 Integrated Voltage Measurement... 16:58:08 Voltage Offset Correction: v_off_ini = 110.345 uV, v_off_fin = 118.872 uV 16:58:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.778 uVs 16:58:08 Integrated Voltage Measurement... 16:58:17 Voltage Offset Correction: v_off_ini = 104.214 uV, v_off_fin = 116.030 uV 16:58:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.922 uVs 16:58:19 I2X Average and RMS of Measurements VT = -37.370 +- 4.355 uVs I2X = 3.438 +- 0.401 uTm^2 16:58:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:58:27 Integrated Voltage Measurement... 16:58:36 Voltage Offset Correction: v_off_ini = 118.362 uV, v_off_fin = 121.055 uV 16:58:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.901 uVs 16:58:36 Integrated Voltage Measurement... 16:58:45 Voltage Offset Correction: v_off_ini = 123.220 uV, v_off_fin = 135.641 uV 16:58:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.156 uVs 16:58:45 Integrated Voltage Measurement... 16:58:54 Voltage Offset Correction: v_off_ini = 137.800 uV, v_off_fin = 130.884 uV 16:58:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.985 uVs 16:58:54 Integrated Voltage Measurement... 16:59:03 Voltage Offset Correction: v_off_ini = 116.245 uV, v_off_fin = 121.838 uV 16:59:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.392 uVs 16:59:03 Integrated Voltage Measurement... 16:59:12 Voltage Offset Correction: v_off_ini = 120.010 uV, v_off_fin = 132.556 uV 16:59:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.723 uVs 16:59:12 Integrated Voltage Measurement... 16:59:21 Voltage Offset Correction: v_off_ini = 133.691 uV, v_off_fin = 130.094 uV 16:59:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.177 uVs 16:59:23 I2Y Average and RMS of Measurements VT = -255.556 +- 4.861 uVs I2Y = -23.511 +- 0.447 uTm^2 16:59:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:59:32 Integrated Voltage Measurement... 16:59:41 Voltage Offset Correction: v_off_ini = 128.302 uV, v_off_fin = 125.244 uV 16:59:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -71.745 uVs 16:59:41 Integrated Voltage Measurement... 16:59:50 Voltage Offset Correction: v_off_ini = 134.180 uV, v_off_fin = 133.890 uV 16:59:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.051 uVs 16:59:50 Integrated Voltage Measurement... 16:59:59 Voltage Offset Correction: v_off_ini = 130.703 uV, v_off_fin = 132.932 uV 16:59:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.142 uVs 16:59:59 Integrated Voltage Measurement... 17:00:08 Voltage Offset Correction: v_off_ini = 138.723 uV, v_off_fin = 144.084 uV 17:00:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.897 uVs 17:00:08 Integrated Voltage Measurement... 17:00:17 Voltage Offset Correction: v_off_ini = 132.466 uV, v_off_fin = 115.875 uV 17:00:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.280 uVs 17:00:17 Integrated Voltage Measurement... 17:00:26 Voltage Offset Correction: v_off_ini = 123.066 uV, v_off_fin = 118.021 uV 17:00:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.634 uVs 17:00:30 I1X Average and RMS of Measurements VT = -68.458 +- 7.078 uVs I1X = 13.692 +- 1.416 uTm 17:00:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:00:37 Integrated Voltage Measurement... 17:00:46 Voltage Offset Correction: v_off_ini = 124.802 uV, v_off_fin = 112.658 uV 17:00:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.736 uVs 17:00:46 Integrated Voltage Measurement... 17:00:55 Voltage Offset Correction: v_off_ini = 117.203 uV, v_off_fin = 124.830 uV 17:00:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.152 uVs 17:00:55 Integrated Voltage Measurement... 17:01:04 Voltage Offset Correction: v_off_ini = 121.807 uV, v_off_fin = 108.339 uV 17:01:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.503 uVs 17:01:04 Integrated Voltage Measurement... 17:01:13 Voltage Offset Correction: v_off_ini = 116.690 uV, v_off_fin = 115.934 uV 17:01:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.643 uVs 17:01:13 Integrated Voltage Measurement... 17:01:22 Voltage Offset Correction: v_off_ini = 130.500 uV, v_off_fin = 118.480 uV 17:01:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.186 uVs 17:01:22 Integrated Voltage Measurement... 17:01:31 Voltage Offset Correction: v_off_ini = 114.146 uV, v_off_fin = 126.271 uV 17:01:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.218 uVs 17:01:35 I1Y Average and RMS of Measurements VT = -274.406 +- 9.047 uVs I1Y = -54.881 +- 1.809 uTm 17:01:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:01:43 Integrated Voltage Measurement... 17:01:52 Voltage Offset Correction: v_off_ini = 107.554 uV, v_off_fin = 122.257 uV 17:01:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -55.167 uVs 17:01:52 Integrated Voltage Measurement... 17:02:01 Voltage Offset Correction: v_off_ini = 126.810 uV, v_off_fin = 126.745 uV 17:02:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.707 uVs 17:02:01 Integrated Voltage Measurement... 17:02:10 Voltage Offset Correction: v_off_ini = 121.937 uV, v_off_fin = 94.829 uV 17:02:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.798 uVs 17:02:10 Integrated Voltage Measurement... 17:02:19 Voltage Offset Correction: v_off_ini = 110.848 uV, v_off_fin = 110.155 uV 17:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.086 uVs 17:02:19 Integrated Voltage Measurement... 17:02:28 Voltage Offset Correction: v_off_ini = 95.018 uV, v_off_fin = 97.368 uV 17:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.864 uVs 17:02:28 Integrated Voltage Measurement... 17:02:37 Voltage Offset Correction: v_off_ini = 95.044 uV, v_off_fin = 100.834 uV 17:02:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 48.445 uVs 17:02:39 I2X Average and RMS of Measurements VT = -48.011 +- 4.715 uVs I2X = 4.417 +- 0.434 uTm^2 17:02:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:02:47 Integrated Voltage Measurement... 17:02:56 Voltage Offset Correction: v_off_ini = 117.191 uV, v_off_fin = 97.499 uV 17:02:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.796 uVs 17:02:56 Integrated Voltage Measurement... 17:03:05 Voltage Offset Correction: v_off_ini = 81.198 uV, v_off_fin = 94.285 uV 17:03:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.444 uVs 17:03:05 Integrated Voltage Measurement... 17:03:14 Voltage Offset Correction: v_off_ini = 84.316 uV, v_off_fin = 83.897 uV 17:03:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.080 uVs 17:03:14 Integrated Voltage Measurement... 17:03:23 Voltage Offset Correction: v_off_ini = 93.683 uV, v_off_fin = 88.020 uV 17:03:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.624 uVs 17:03:23 Integrated Voltage Measurement... 17:03:32 Voltage Offset Correction: v_off_ini = 98.686 uV, v_off_fin = 101.333 uV 17:03:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.642 uVs 17:03:32 Integrated Voltage Measurement... 17:03:41 Voltage Offset Correction: v_off_ini = 87.273 uV, v_off_fin = 99.107 uV 17:03:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.227 uVs 17:03:44 I2Y Average and RMS of Measurements VT = -238.302 +- 6.330 uVs I2Y = -21.924 +- 0.582 uTm^2 17:03:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:03:53 Integrated Voltage Measurement... 17:04:02 Voltage Offset Correction: v_off_ini = 88.298 uV, v_off_fin = 89.600 uV 17:04:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.534 uVs 17:04:02 Integrated Voltage Measurement... 17:04:11 Voltage Offset Correction: v_off_ini = 95.658 uV, v_off_fin = 101.558 uV 17:04:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.363 uVs 17:04:11 Integrated Voltage Measurement... 17:04:20 Voltage Offset Correction: v_off_ini = 88.205 uV, v_off_fin = 81.134 uV 17:04:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.624 uVs 17:04:20 Integrated Voltage Measurement... 17:04:29 Voltage Offset Correction: v_off_ini = 81.149 uV, v_off_fin = 86.400 uV 17:04:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.680 uVs 17:04:29 Integrated Voltage Measurement... 17:04:38 Voltage Offset Correction: v_off_ini = 67.399 uV, v_off_fin = 68.460 uV 17:04:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -61.729 uVs 17:04:38 Integrated Voltage Measurement... 17:04:47 Voltage Offset Correction: v_off_ini = 73.154 uV, v_off_fin = 81.265 uV 17:04:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.003 uVs 17:04:51 I1X Average and RMS of Measurements VT = -68.822 +- 5.400 uVs I1X = 13.765 +- 1.080 uTm 17:04:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:04:58 Integrated Voltage Measurement... 17:05:07 Voltage Offset Correction: v_off_ini = 90.428 uV, v_off_fin = 80.077 uV 17:05:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.838 uVs 17:05:07 Integrated Voltage Measurement... 17:05:16 Voltage Offset Correction: v_off_ini = 102.070 uV, v_off_fin = 123.979 uV 17:05:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.951 uVs 17:05:16 Integrated Voltage Measurement... 17:05:24 Voltage Offset Correction: v_off_ini = 109.334 uV, v_off_fin = 92.066 uV 17:05:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.461 uVs 17:05:25 Integrated Voltage Measurement... 17:05:33 Voltage Offset Correction: v_off_ini = 100.301 uV, v_off_fin = 114.982 uV 17:05:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.307 uVs 17:05:34 Integrated Voltage Measurement... 17:05:42 Voltage Offset Correction: v_off_ini = 90.435 uV, v_off_fin = 89.667 uV 17:05:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -274.633 uVs 17:05:43 Integrated Voltage Measurement... 17:05:51 Voltage Offset Correction: v_off_ini = 91.851 uV, v_off_fin = 101.624 uV 17:05:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.915 uVs 17:05:56 I1Y Average and RMS of Measurements VT = -260.184 +- 8.946 uVs I1Y = -52.037 +- 1.789 uTm 17:06:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:06:03 Integrated Voltage Measurement... 17:06:12 Voltage Offset Correction: v_off_ini = 106.433 uV, v_off_fin = 102.375 uV 17:06:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.322 uVs 17:06:12 Integrated Voltage Measurement... 17:06:21 Voltage Offset Correction: v_off_ini = 119.286 uV, v_off_fin = 110.389 uV 17:06:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.214 uVs 17:06:21 Integrated Voltage Measurement... 17:06:30 Voltage Offset Correction: v_off_ini = 113.778 uV, v_off_fin = 98.763 uV 17:06:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.564 uVs 17:06:30 Integrated Voltage Measurement... 17:06:39 Voltage Offset Correction: v_off_ini = 96.177 uV, v_off_fin = 116.372 uV 17:06:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.306 uVs 17:06:39 Integrated Voltage Measurement... 17:06:48 Voltage Offset Correction: v_off_ini = 116.720 uV, v_off_fin = 107.717 uV 17:06:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.478 uVs 17:06:48 Integrated Voltage Measurement... 17:06:57 Voltage Offset Correction: v_off_ini = 97.090 uV, v_off_fin = 115.957 uV 17:06:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.924 uVs 17:07:00 I2X Average and RMS of Measurements VT = -55.801 +- 8.669 uVs I2X = 5.134 +- 0.798 uTm^2 17:07:05 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:07:08 Integrated Voltage Measurement... 17:07:17 Voltage Offset Correction: v_off_ini = 96.205 uV, v_off_fin = 110.385 uV 17:07:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.903 uVs 17:07:17 Integrated Voltage Measurement... 17:07:26 Voltage Offset Correction: v_off_ini = 110.050 uV, v_off_fin = 113.257 uV 17:07:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.655 uVs 17:07:26 Integrated Voltage Measurement... 17:07:35 Voltage Offset Correction: v_off_ini = 111.630 uV, v_off_fin = 104.922 uV 17:07:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.350 uVs 17:07:35 Integrated Voltage Measurement... 17:07:44 Voltage Offset Correction: v_off_ini = 104.768 uV, v_off_fin = 107.877 uV 17:07:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.639 uVs 17:07:44 Integrated Voltage Measurement... 17:07:53 Voltage Offset Correction: v_off_ini = 101.485 uV, v_off_fin = 107.661 uV 17:07:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.314 uVs 17:07:53 Integrated Voltage Measurement... 17:08:02 Voltage Offset Correction: v_off_ini = 98.782 uV, v_off_fin = 108.256 uV 17:08:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.231 uVs 17:08:04 I2Y Average and RMS of Measurements VT = -231.182 +- 3.776 uVs I2Y = -21.269 +- 0.347 uTm^2 17:08:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:08:13 Integrated Voltage Measurement... 17:08:22 Voltage Offset Correction: v_off_ini = 115.031 uV, v_off_fin = 86.434 uV 17:08:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.014 uVs 17:08:22 Integrated Voltage Measurement... 17:08:31 Voltage Offset Correction: v_off_ini = 124.000 uV, v_off_fin = 110.672 uV 17:08:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.381 uVs 17:08:31 Integrated Voltage Measurement... 17:08:40 Voltage Offset Correction: v_off_ini = 108.797 uV, v_off_fin = 100.045 uV 17:08:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.562 uVs 17:08:40 Integrated Voltage Measurement... 17:08:49 Voltage Offset Correction: v_off_ini = 99.174 uV, v_off_fin = 118.922 uV 17:08:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 83.987 uVs 17:08:49 Integrated Voltage Measurement... 17:08:58 Voltage Offset Correction: v_off_ini = 96.854 uV, v_off_fin = 101.018 uV 17:08:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.913 uVs 17:08:58 Integrated Voltage Measurement... 17:09:07 Voltage Offset Correction: v_off_ini = 99.062 uV, v_off_fin = 111.164 uV 17:09:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 75.385 uVs 17:09:11 I1X Average and RMS of Measurements VT = -77.540 +- 4.230 uVs I1X = 15.509 +- 0.846 uTm 17:09:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:09:18 Integrated Voltage Measurement... 17:09:27 Voltage Offset Correction: v_off_ini = 103.604 uV, v_off_fin = 99.336 uV 17:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.678 uVs 17:09:27 Integrated Voltage Measurement... 17:09:36 Voltage Offset Correction: v_off_ini = 92.527 uV, v_off_fin = 110.788 uV 17:09:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.322 uVs 17:09:36 Integrated Voltage Measurement... 17:09:45 Voltage Offset Correction: v_off_ini = 93.951 uV, v_off_fin = 86.920 uV 17:09:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.752 uVs 17:09:45 Integrated Voltage Measurement... 17:09:54 Voltage Offset Correction: v_off_ini = 95.220 uV, v_off_fin = 110.244 uV 17:09:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.034 uVs 17:09:54 Integrated Voltage Measurement... 17:10:03 Voltage Offset Correction: v_off_ini = 103.251 uV, v_off_fin = 103.788 uV 17:10:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.160 uVs 17:10:03 Integrated Voltage Measurement... 17:10:12 Voltage Offset Correction: v_off_ini = 113.857 uV, v_off_fin = 125.566 uV 17:10:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.497 uVs 17:10:16 I1Y Average and RMS of Measurements VT = -254.907 +- 3.655 uVs I1Y = -50.981 +- 0.731 uTm 17:10:21 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:10:24 Integrated Voltage Measurement... 17:10:33 Voltage Offset Correction: v_off_ini = 115.145 uV, v_off_fin = 103.654 uV 17:10:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.426 uVs 17:10:33 Integrated Voltage Measurement... 17:10:42 Voltage Offset Correction: v_off_ini = 120.687 uV, v_off_fin = 121.793 uV 17:10:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.445 uVs 17:10:42 Integrated Voltage Measurement... 17:10:51 Voltage Offset Correction: v_off_ini = 115.198 uV, v_off_fin = 96.009 uV 17:10:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.391 uVs 17:10:51 Integrated Voltage Measurement... 17:11:00 Voltage Offset Correction: v_off_ini = 109.940 uV, v_off_fin = 118.553 uV 17:11:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.023 uVs 17:11:00 Integrated Voltage Measurement... 17:11:09 Voltage Offset Correction: v_off_ini = 101.600 uV, v_off_fin = 92.941 uV 17:11:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.459 uVs 17:11:09 Integrated Voltage Measurement... 17:11:18 Voltage Offset Correction: v_off_ini = 105.058 uV, v_off_fin = 110.278 uV 17:11:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.646 uVs 17:11:20 I2X Average and RMS of Measurements VT = -63.232 +- 7.132 uVs I2X = 5.817 +- 0.656 uTm^2 17:11:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:11:28 Integrated Voltage Measurement... 17:11:37 Voltage Offset Correction: v_off_ini = 91.800 uV, v_off_fin = 75.802 uV 17:11:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.270 uVs 17:11:37 Integrated Voltage Measurement... 17:11:46 Voltage Offset Correction: v_off_ini = 74.868 uV, v_off_fin = 75.776 uV 17:11:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.870 uVs 17:11:46 Integrated Voltage Measurement... 17:11:55 Voltage Offset Correction: v_off_ini = 70.499 uV, v_off_fin = 76.234 uV 17:11:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.386 uVs 17:11:55 Integrated Voltage Measurement... 17:12:04 Voltage Offset Correction: v_off_ini = 77.437 uV, v_off_fin = 80.928 uV 17:12:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.368 uVs 17:12:04 Integrated Voltage Measurement... 17:12:13 Voltage Offset Correction: v_off_ini = 90.690 uV, v_off_fin = 87.027 uV 17:12:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.869 uVs 17:12:13 Integrated Voltage Measurement... 17:12:22 Voltage Offset Correction: v_off_ini = 95.727 uV, v_off_fin = 91.897 uV 17:12:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.020 uVs 17:12:24 I2Y Average and RMS of Measurements VT = -229.797 +- 6.251 uVs I2Y = -21.141 +- 0.575 uTm^2 17:12:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:12:36 Integrated Voltage Measurement... 17:12:45 Voltage Offset Correction: v_off_ini = 94.804 uV, v_off_fin = 87.729 uV 17:12:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -56.868 uVs 17:12:45 Integrated Voltage Measurement... 17:12:54 Voltage Offset Correction: v_off_ini = 106.562 uV, v_off_fin = 87.805 uV 17:12:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.903 uVs 17:12:54 Integrated Voltage Measurement... 17:13:03 Voltage Offset Correction: v_off_ini = 102.586 uV, v_off_fin = 88.739 uV 17:13:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -32.422 uVs 17:13:03 Integrated Voltage Measurement... 17:13:12 Voltage Offset Correction: v_off_ini = 91.955 uV, v_off_fin = 87.500 uV 17:13:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.507 uVs 17:13:12 Integrated Voltage Measurement... 17:13:21 Voltage Offset Correction: v_off_ini = 85.404 uV, v_off_fin = 94.921 uV 17:13:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.071 uVs 17:13:21 Integrated Voltage Measurement... 17:13:30 Voltage Offset Correction: v_off_ini = 81.060 uV, v_off_fin = 96.511 uV 17:13:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.389 uVs 17:13:35 I1X Average and RMS of Measurements VT = -50.027 +- 8.352 uVs I1X = 10.006 +- 1.670 uTm 17:13:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:13:41 Integrated Voltage Measurement... 17:13:50 Voltage Offset Correction: v_off_ini = 95.393 uV, v_off_fin = 74.571 uV 17:13:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.620 uVs 17:13:50 Integrated Voltage Measurement... 17:13:59 Voltage Offset Correction: v_off_ini = 96.550 uV, v_off_fin = 112.348 uV 17:13:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.210 uVs 17:13:59 Integrated Voltage Measurement... 17:14:08 Voltage Offset Correction: v_off_ini = 88.731 uV, v_off_fin = 79.619 uV 17:14:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.177 uVs 17:14:08 Integrated Voltage Measurement... 17:14:17 Voltage Offset Correction: v_off_ini = 80.378 uV, v_off_fin = 96.355 uV 17:14:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.737 uVs 17:14:17 Integrated Voltage Measurement... 17:14:26 Voltage Offset Correction: v_off_ini = 83.133 uV, v_off_fin = 76.763 uV 17:14:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.748 uVs 17:14:26 Integrated Voltage Measurement... 17:14:35 Voltage Offset Correction: v_off_ini = 81.955 uV, v_off_fin = 96.250 uV 17:14:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.560 uVs 17:14:39 I1Y Average and RMS of Measurements VT = -262.675 +- 3.525 uVs I1Y = -52.535 +- 0.705 uTm 17:14:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:14:45 Integrated Voltage Measurement... 17:14:54 Voltage Offset Correction: v_off_ini = 83.795 uV, v_off_fin = 84.825 uV 17:14:54 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -21.314 uVs 17:14:54 Integrated Voltage Measurement... 17:15:03 Voltage Offset Correction: v_off_ini = 98.606 uV, v_off_fin = 106.102 uV 17:15:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.507 uVs 17:15:03 Integrated Voltage Measurement... 17:15:12 Voltage Offset Correction: v_off_ini = 87.178 uV, v_off_fin = 94.655 uV 17:15:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.655 uVs 17:15:12 Integrated Voltage Measurement... 17:15:21 Voltage Offset Correction: v_off_ini = 109.300 uV, v_off_fin = 107.501 uV 17:15:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.660 uVs 17:15:21 Integrated Voltage Measurement... 17:15:30 Voltage Offset Correction: v_off_ini = 94.509 uV, v_off_fin = 77.384 uV 17:15:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.685 uVs 17:15:30 Integrated Voltage Measurement... 17:15:39 Voltage Offset Correction: v_off_ini = 83.422 uV, v_off_fin = 88.976 uV 17:15:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.572 uVs 17:15:41 I2X Average and RMS of Measurements VT = -26.232 +- 14.856 uVs I2X = 2.413 +- 1.367 uTm^2 17:15:44 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:15:46 Integrated Voltage Measurement... 17:15:55 Voltage Offset Correction: v_off_ini = 92.526 uV, v_off_fin = 93.324 uV 17:15:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.996 uVs 17:15:55 Integrated Voltage Measurement... 17:16:04 Voltage Offset Correction: v_off_ini = 112.453 uV, v_off_fin = 92.552 uV 17:16:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.283 uVs 17:16:04 Integrated Voltage Measurement... 17:16:13 Voltage Offset Correction: v_off_ini = 97.185 uV, v_off_fin = 83.921 uV 17:16:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.807 uVs 17:16:13 Integrated Voltage Measurement... 17:16:22 Voltage Offset Correction: v_off_ini = 98.329 uV, v_off_fin = 75.537 uV 17:16:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.900 uVs 17:16:22 Integrated Voltage Measurement... 17:16:31 Voltage Offset Correction: v_off_ini = 82.905 uV, v_off_fin = 54.142 uV 17:16:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.055 uVs 17:16:31 Integrated Voltage Measurement... 17:16:40 Voltage Offset Correction: v_off_ini = 65.954 uV, v_off_fin = 73.401 uV 17:16:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.023 uVs 17:16:43 I2Y Average and RMS of Measurements VT = -228.844 +- 2.987 uVs I2Y = -21.054 +- 0.275 uTm^2 17:16:47 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:16:51 Integrated Voltage Measurement... 17:17:00 Voltage Offset Correction: v_off_ini = 66.904 uV, v_off_fin = 58.623 uV 17:17:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -56.768 uVs 17:17:00 Integrated Voltage Measurement... 17:17:09 Voltage Offset Correction: v_off_ini = 62.651 uV, v_off_fin = 60.408 uV 17:17:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 57.687 uVs 17:17:09 Integrated Voltage Measurement... 17:17:18 Voltage Offset Correction: v_off_ini = 59.400 uV, v_off_fin = 69.738 uV 17:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.734 uVs 17:17:18 Integrated Voltage Measurement... 17:17:27 Voltage Offset Correction: v_off_ini = 60.977 uV, v_off_fin = 69.260 uV 17:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.664 uVs 17:17:27 Integrated Voltage Measurement... 17:17:36 Voltage Offset Correction: v_off_ini = 62.744 uV, v_off_fin = 57.907 uV 17:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.201 uVs 17:17:36 Integrated Voltage Measurement... 17:17:45 Voltage Offset Correction: v_off_ini = 43.958 uV, v_off_fin = 60.510 uV 17:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.713 uVs 17:17:49 I1X Average and RMS of Measurements VT = -54.128 +- 2.675 uVs I1X = 10.826 +- 0.536 uTm 17:17:52 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:17:56 Integrated Voltage Measurement... 17:18:05 Voltage Offset Correction: v_off_ini = 53.565 uV, v_off_fin = 54.708 uV 17:18:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -274.437 uVs 17:18:05 Integrated Voltage Measurement... 17:18:14 Voltage Offset Correction: v_off_ini = 61.949 uV, v_off_fin = 68.102 uV 17:18:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.747 uVs 17:18:14 Integrated Voltage Measurement... 17:18:23 Voltage Offset Correction: v_off_ini = 62.525 uV, v_off_fin = 67.252 uV 17:18:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.666 uVs 17:18:23 Integrated Voltage Measurement... 17:18:32 Voltage Offset Correction: v_off_ini = 66.621 uV, v_off_fin = 67.837 uV 17:18:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.971 uVs 17:18:32 Integrated Voltage Measurement... 17:18:41 Voltage Offset Correction: v_off_ini = 53.384 uV, v_off_fin = 48.210 uV 17:18:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.809 uVs 17:18:41 Integrated Voltage Measurement... 17:18:50 Voltage Offset Correction: v_off_ini = 50.600 uV, v_off_fin = 73.416 uV 17:18:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.037 uVs 17:18:54 I1Y Average and RMS of Measurements VT = -267.278 +- 5.431 uVs I1Y = -53.456 +- 1.086 uTm 17:18:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:18:59 Integrated Voltage Measurement... 17:19:08 Voltage Offset Correction: v_off_ini = 56.902 uV, v_off_fin = 55.568 uV 17:19:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.175 uVs 17:19:08 Integrated Voltage Measurement... 17:19:17 Voltage Offset Correction: v_off_ini = 61.399 uV, v_off_fin = 68.957 uV 17:19:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.616 uVs 17:19:17 Integrated Voltage Measurement... 17:19:26 Voltage Offset Correction: v_off_ini = 54.464 uV, v_off_fin = 46.800 uV 17:19:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.248 uVs 17:19:26 Integrated Voltage Measurement... 17:19:35 Voltage Offset Correction: v_off_ini = 52.600 uV, v_off_fin = 61.306 uV 17:19:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.311 uVs 17:19:35 Integrated Voltage Measurement... 17:19:44 Voltage Offset Correction: v_off_ini = 53.620 uV, v_off_fin = 56.983 uV 17:19:44 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -48.078 uVs 17:19:44 Integrated Voltage Measurement... 17:19:53 Voltage Offset Correction: v_off_ini = 55.851 uV, v_off_fin = 72.357 uV 17:19:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 37.540 uVs 17:19:56 I2X Average and RMS of Measurements VT = -45.661 +- 5.531 uVs I2X = 4.201 +- 0.509 uTm^2 17:19:58 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:20:01 Integrated Voltage Measurement... 17:20:10 Voltage Offset Correction: v_off_ini = 48.140 uV, v_off_fin = 43.175 uV 17:20:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.035 uVs 17:20:10 Integrated Voltage Measurement... 17:20:19 Voltage Offset Correction: v_off_ini = 56.989 uV, v_off_fin = 59.268 uV 17:20:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.431 uVs 17:20:19 Integrated Voltage Measurement... 17:20:28 Voltage Offset Correction: v_off_ini = 50.390 uV, v_off_fin = 44.091 uV 17:20:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.196 uVs 17:20:28 Integrated Voltage Measurement... 17:20:37 Voltage Offset Correction: v_off_ini = 48.842 uV, v_off_fin = 41.829 uV 17:20:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.473 uVs 17:20:37 Integrated Voltage Measurement... 17:20:46 Voltage Offset Correction: v_off_ini = 39.889 uV, v_off_fin = 40.517 uV 17:20:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.168 uVs 17:20:46 Integrated Voltage Measurement... 17:20:55 Voltage Offset Correction: v_off_ini = 42.809 uV, v_off_fin = 37.298 uV 17:20:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.167 uVs 17:20:57 I2Y Average and RMS of Measurements VT = -242.412 +- 8.431 uVs I2Y = -22.302 +- 0.776 uTm^2 17:21:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:21:06 Integrated Voltage Measurement... 17:21:15 Voltage Offset Correction: v_off_ini = 79.149 uV, v_off_fin = 69.233 uV 17:21:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.013 uVs 17:21:15 Integrated Voltage Measurement... 17:21:24 Voltage Offset Correction: v_off_ini = 70.652 uV, v_off_fin = 64.283 uV 17:21:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.062 uVs 17:21:24 Integrated Voltage Measurement... 17:21:33 Voltage Offset Correction: v_off_ini = 58.267 uV, v_off_fin = 41.781 uV 17:21:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.451 uVs 17:21:33 Integrated Voltage Measurement... 17:21:42 Voltage Offset Correction: v_off_ini = 46.619 uV, v_off_fin = 57.013 uV 17:21:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.610 uVs 17:21:42 Integrated Voltage Measurement... 17:21:51 Voltage Offset Correction: v_off_ini = 38.891 uV, v_off_fin = 54.413 uV 17:21:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.528 uVs 17:21:51 Integrated Voltage Measurement... 17:22:00 Voltage Offset Correction: v_off_ini = 64.608 uV, v_off_fin = 65.306 uV 17:22:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.339 uVs 17:22:04 I1X Average and RMS of Measurements VT = -61.167 +- 3.486 uVs I1X = 12.233 +- 0.697 uTm 17:22:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:22:11 Integrated Voltage Measurement... 17:22:20 Voltage Offset Correction: v_off_ini = 28.413 uV, v_off_fin = 51.070 uV 17:22:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.639 uVs 17:22:20 Integrated Voltage Measurement... 17:22:29 Voltage Offset Correction: v_off_ini = 58.391 uV, v_off_fin = 60.673 uV 17:22:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.575 uVs 17:22:29 Integrated Voltage Measurement... 17:22:38 Voltage Offset Correction: v_off_ini = 57.591 uV, v_off_fin = 52.304 uV 17:22:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.528 uVs 17:22:38 Integrated Voltage Measurement... 17:22:46 Voltage Offset Correction: v_off_ini = 56.065 uV, v_off_fin = 73.049 uV 17:22:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.981 uVs 17:22:47 Integrated Voltage Measurement... 17:22:55 Voltage Offset Correction: v_off_ini = 54.940 uV, v_off_fin = 31.858 uV 17:22:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.249 uVs 17:22:56 Integrated Voltage Measurement... 17:23:04 Voltage Offset Correction: v_off_ini = 41.395 uV, v_off_fin = 47.462 uV 17:23:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.242 uVs 17:23:09 I1Y Average and RMS of Measurements VT = -273.702 +- 6.402 uVs I1Y = -54.740 +- 1.280 uTm 17:23:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:23:14 Integrated Voltage Measurement... 17:23:23 Voltage Offset Correction: v_off_ini = 44.515 uV, v_off_fin = 26.199 uV 17:23:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.472 uVs 17:23:23 Integrated Voltage Measurement... 17:23:32 Voltage Offset Correction: v_off_ini = 46.643 uV, v_off_fin = 49.282 uV 17:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.181 uVs 17:23:32 Integrated Voltage Measurement... 17:23:41 Voltage Offset Correction: v_off_ini = 30.176 uV, v_off_fin = 33.259 uV 17:23:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -36.403 uVs 17:23:41 Integrated Voltage Measurement... 17:23:50 Voltage Offset Correction: v_off_ini = 33.368 uV, v_off_fin = 38.937 uV 17:23:50 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 43.422 uVs 17:23:50 Integrated Voltage Measurement... 17:23:59 Voltage Offset Correction: v_off_ini = 31.042 uV, v_off_fin = 18.770 uV 17:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.385 uVs 17:23:59 Integrated Voltage Measurement... 17:24:08 Voltage Offset Correction: v_off_ini = 31.729 uV, v_off_fin = 32.319 uV 17:24:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.040 uVs 17:24:10 I2X Average and RMS of Measurements VT = -43.317 +- 4.262 uVs I2X = 3.985 +- 0.392 uTm^2 17:24:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:24:15 Integrated Voltage Measurement... 17:24:24 Voltage Offset Correction: v_off_ini = 22.602 uV, v_off_fin = 12.092 uV 17:24:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.293 uVs 17:24:24 Integrated Voltage Measurement... 17:24:33 Voltage Offset Correction: v_off_ini = 17.017 uV, v_off_fin = 28.500 uV 17:24:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.830 uVs 17:24:33 Integrated Voltage Measurement... 17:24:42 Voltage Offset Correction: v_off_ini = 21.849 uV, v_off_fin = 21.077 uV 17:24:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.104 uVs 17:24:42 Integrated Voltage Measurement... 17:24:51 Voltage Offset Correction: v_off_ini = 23.921 uV, v_off_fin = 24.030 uV 17:24:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.512 uVs 17:24:52 Integrated Voltage Measurement... 17:25:00 Voltage Offset Correction: v_off_ini = 20.047 uV, v_off_fin = 19.843 uV 17:25:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.053 uVs 17:25:01 Integrated Voltage Measurement... 17:25:10 Voltage Offset Correction: v_off_ini = 15.858 uV, v_off_fin = 23.854 uV 17:25:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.370 uVs 17:25:12 I2Y Average and RMS of Measurements VT = -240.694 +- 5.313 uVs I2Y = -22.144 +- 0.489 uTm^2 17:25:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:25:20 Integrated Voltage Measurement... 17:25:29 Voltage Offset Correction: v_off_ini = 19.303 uV, v_off_fin = 13.290 uV 17:25:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.902 uVs 17:25:29 Integrated Voltage Measurement... 17:25:38 Voltage Offset Correction: v_off_ini = 26.742 uV, v_off_fin = 32.621 uV 17:25:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.074 uVs 17:25:38 Integrated Voltage Measurement... 17:25:47 Voltage Offset Correction: v_off_ini = 38.624 uV, v_off_fin = 35.936 uV 17:25:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.146 uVs 17:25:47 Integrated Voltage Measurement... 17:25:56 Voltage Offset Correction: v_off_ini = 43.549 uV, v_off_fin = 38.152 uV 17:25:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.594 uVs 17:25:56 Integrated Voltage Measurement... 17:26:05 Voltage Offset Correction: v_off_ini = 42.735 uV, v_off_fin = 31.892 uV 17:26:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.020 uVs 17:26:05 Integrated Voltage Measurement... 17:26:14 Voltage Offset Correction: v_off_ini = 40.311 uV, v_off_fin = 23.760 uV 17:26:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.297 uVs 17:26:18 I1X Average and RMS of Measurements VT = -73.672 +- 7.050 uVs I1X = 14.735 +- 1.410 uTm 17:26:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:26:25 Integrated Voltage Measurement... 17:26:34 Voltage Offset Correction: v_off_ini = 13.050 uV, v_off_fin = 8.272 uV 17:26:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.957 uVs 17:26:34 Integrated Voltage Measurement... 17:26:43 Voltage Offset Correction: v_off_ini = 20.283 uV, v_off_fin = 50.097 uV 17:26:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.434 uVs 17:26:43 Integrated Voltage Measurement... 17:26:52 Voltage Offset Correction: v_off_ini = 24.980 uV, v_off_fin = 4.409 uV 17:26:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.075 uVs 17:26:52 Integrated Voltage Measurement... 17:27:01 Voltage Offset Correction: v_off_ini = 32.228 uV, v_off_fin = 41.770 uV 17:27:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.966 uVs 17:27:01 Integrated Voltage Measurement... 17:27:10 Voltage Offset Correction: v_off_ini = 7.323 uV, v_off_fin = 5.310 uV 17:27:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -275.135 uVs 17:27:10 Integrated Voltage Measurement... 17:27:19 Voltage Offset Correction: v_off_ini = 26.521 uV, v_off_fin = 30.630 uV 17:27:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 273.040 uVs 17:27:23 I1Y Average and RMS of Measurements VT = -272.268 +- 1.976 uVs I1Y = -54.452 +- 0.394 uTm 17:27:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:27:28 Integrated Voltage Measurement... 17:27:37 Voltage Offset Correction: v_off_ini = 32.223 uV, v_off_fin = 16.260 uV 17:27:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.237 uVs 17:27:37 Integrated Voltage Measurement... 17:27:46 Voltage Offset Correction: v_off_ini = 7.689 uV, v_off_fin = 22.878 uV 17:27:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.490 uVs 17:27:47 Integrated Voltage Measurement... 17:27:56 Voltage Offset Correction: v_off_ini = 25.821 uV, v_off_fin = 20.031 uV 17:27:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.137 uVs 17:27:56 Integrated Voltage Measurement... 17:28:05 Voltage Offset Correction: v_off_ini = 18.136 uV, v_off_fin = 18.808 uV 17:28:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.672 uVs 17:28:05 Integrated Voltage Measurement... 17:28:14 Voltage Offset Correction: v_off_ini = 18.137 uV, v_off_fin = 3.194 uV 17:28:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.208 uVs 17:28:14 Integrated Voltage Measurement... 17:28:23 Voltage Offset Correction: v_off_ini = 18.532 uV, v_off_fin = 15.236 uV 17:28:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.205 uVs 17:28:25 I2X Average and RMS of Measurements VT = -53.492 +- 2.933 uVs I2X = 4.921 +- 0.270 uTm^2 17:28:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:28:30 Integrated Voltage Measurement... 17:28:39 Voltage Offset Correction: v_off_ini = 3.292 uV, v_off_fin = -5.550 uV 17:28:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.910 uVs 17:28:39 Integrated Voltage Measurement... 17:28:48 Voltage Offset Correction: v_off_ini = -4.461 uV, v_off_fin = -8.071 uV 17:28:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.785 uVs 17:28:48 Integrated Voltage Measurement... 17:28:57 Voltage Offset Correction: v_off_ini = 5.471 uV, v_off_fin = 8.625 uV 17:28:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.690 uVs 17:28:57 Integrated Voltage Measurement... 17:29:06 Voltage Offset Correction: v_off_ini = 11.614 uV, v_off_fin = 7.690 uV 17:29:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.289 uVs 17:29:06 Integrated Voltage Measurement... 17:29:15 Voltage Offset Correction: v_off_ini = 3.014 uV, v_off_fin = 5.520 uV 17:29:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.084 uVs 17:29:15 Integrated Voltage Measurement... 17:29:24 Voltage Offset Correction: v_off_ini = 7.532 uV, v_off_fin = -5.557 uV 17:29:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.164 uVs 17:29:27 I2Y Average and RMS of Measurements VT = -247.154 +- 5.326 uVs I2Y = -22.738 +- 0.490 uTm^2 17:29:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:29:35 Integrated Voltage Measurement... 17:29:44 Voltage Offset Correction: v_off_ini = 5.154 uV, v_off_fin = 20.967 uV 17:29:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -52.810 uVs 17:29:44 Integrated Voltage Measurement... 17:29:53 Voltage Offset Correction: v_off_ini = 19.242 uV, v_off_fin = 22.124 uV 17:29:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.318 uVs 17:29:53 Integrated Voltage Measurement... 17:30:02 Voltage Offset Correction: v_off_ini = -6.491 uV, v_off_fin = 2.412 uV 17:30:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.681 uVs 17:30:02 Integrated Voltage Measurement... 17:30:11 Voltage Offset Correction: v_off_ini = 4.714 uV, v_off_fin = 17.151 uV 17:30:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.903 uVs 17:30:11 Integrated Voltage Measurement... 17:30:20 Voltage Offset Correction: v_off_ini = 8.795 uV, v_off_fin = 0.502 uV 17:30:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.495 uVs 17:30:20 Integrated Voltage Measurement... 17:30:29 Voltage Offset Correction: v_off_ini = 12.127 uV, v_off_fin = 12.929 uV 17:30:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.844 uVs 17:30:33 I1X Average and RMS of Measurements VT = -66.009 +- 8.165 uVs I1X = 13.202 +- 1.633 uTm 17:30:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:30:40 Integrated Voltage Measurement... 17:30:49 Voltage Offset Correction: v_off_ini = 2.187 uV, v_off_fin = -6.981 uV 17:30:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.714 uVs 17:30:49 Integrated Voltage Measurement... 17:30:58 Voltage Offset Correction: v_off_ini = -12.235 uV, v_off_fin = 13.774 uV 17:30:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 286.295 uVs 17:30:58 Integrated Voltage Measurement... 17:31:07 Voltage Offset Correction: v_off_ini = 0.942 uV, v_off_fin = -18.622 uV 17:31:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -268.017 uVs 17:31:07 Integrated Voltage Measurement... 17:31:16 Voltage Offset Correction: v_off_ini = 1.378 uV, v_off_fin = 11.038 uV 17:31:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 277.300 uVs 17:31:16 Integrated Voltage Measurement... 17:31:25 Voltage Offset Correction: v_off_ini = 20.972 uV, v_off_fin = -6.102 uV 17:31:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -270.202 uVs 17:31:25 Integrated Voltage Measurement... 17:31:34 Voltage Offset Correction: v_off_ini = 17.048 uV, v_off_fin = 17.137 uV 17:31:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 283.804 uVs 17:31:38 I1Y Average and RMS of Measurements VT = -274.388 +- 1.881 uVs I1Y = -54.873 +- 0.376 uTm 17:31:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:31:43 Integrated Voltage Measurement... 17:31:52 Voltage Offset Correction: v_off_ini = 4.390 uV, v_off_fin = -14.519 uV 17:31:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -32.519 uVs 17:31:52 Integrated Voltage Measurement... 17:32:01 Voltage Offset Correction: v_off_ini = -16.996 uV, v_off_fin = -15.884 uV 17:32:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.856 uVs 17:32:01 Integrated Voltage Measurement... 17:32:10 Voltage Offset Correction: v_off_ini = -27.672 uV, v_off_fin = -30.055 uV 17:32:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.262 uVs 17:32:10 Integrated Voltage Measurement... 17:32:19 Voltage Offset Correction: v_off_ini = -31.210 uV, v_off_fin = -23.403 uV 17:32:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.336 uVs 17:32:19 Integrated Voltage Measurement... 17:32:28 Voltage Offset Correction: v_off_ini = -10.616 uV, v_off_fin = -31.072 uV 17:32:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.192 uVs 17:32:28 Integrated Voltage Measurement... 17:32:37 Voltage Offset Correction: v_off_ini = -26.338 uV, v_off_fin = -20.177 uV 17:32:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.021 uVs 17:32:40 I2X Average and RMS of Measurements VT = -42.698 +- 3.115 uVs I2X = 3.928 +- 0.287 uTm^2 17:32:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:32:45 Integrated Voltage Measurement... 17:32:54 Voltage Offset Correction: v_off_ini = -4.035 uV, v_off_fin = -12.781 uV 17:32:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.460 uVs 17:32:54 Integrated Voltage Measurement... 17:33:03 Voltage Offset Correction: v_off_ini = -16.062 uV, v_off_fin = -10.418 uV 17:33:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.838 uVs 17:33:03 Integrated Voltage Measurement... 17:33:12 Voltage Offset Correction: v_off_ini = -7.333 uV, v_off_fin = 2.272 uV 17:33:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.974 uVs 17:33:12 Integrated Voltage Measurement... 17:33:21 Voltage Offset Correction: v_off_ini = 1.538 uV, v_off_fin = -3.922 uV 17:33:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.632 uVs 17:33:21 Integrated Voltage Measurement... 17:33:30 Voltage Offset Correction: v_off_ini = -9.006 uV, v_off_fin = -6.289 uV 17:33:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.104 uVs 17:33:30 Integrated Voltage Measurement... 17:33:39 Voltage Offset Correction: v_off_ini = -9.281 uV, v_off_fin = -5.121 uV 17:33:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.847 uVs 17:33:41 I2Y Average and RMS of Measurements VT = -253.976 +- 3.316 uVs I2Y = -23.366 +- 0.305 uTm^2 17:33:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:34:02 Integrated Voltage Measurement... 17:34:11 Voltage Offset Correction: v_off_ini = -4.502 uV, v_off_fin = -23.351 uV 17:34:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.438 uVs 17:34:11 Integrated Voltage Measurement... 17:34:20 Voltage Offset Correction: v_off_ini = -31.924 uV, v_off_fin = -9.013 uV 17:34:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.320 uVs 17:34:20 Integrated Voltage Measurement... 17:34:29 Voltage Offset Correction: v_off_ini = 0.853 uV, v_off_fin = -9.715 uV 17:34:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.611 uVs 17:34:29 Integrated Voltage Measurement... 17:34:38 Voltage Offset Correction: v_off_ini = 3.113 uV, v_off_fin = 12.506 uV 17:34:38 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.249 uVs 17:34:38 Integrated Voltage Measurement... 17:34:47 Voltage Offset Correction: v_off_ini = 1.940 uV, v_off_fin = 7.284 uV 17:34:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.022 uVs 17:34:47 Integrated Voltage Measurement... 17:34:56 Voltage Offset Correction: v_off_ini = 3.173 uV, v_off_fin = 10.961 uV 17:34:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.304 uVs 17:35:01 I1X Average and RMS of Measurements VT = -39.824 +- 7.329 uVs I1X = 7.965 +- 1.465 uTm 17:35:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:35:07 Integrated Voltage Measurement... 17:35:16 Voltage Offset Correction: v_off_ini = -13.576 uV, v_off_fin = -26.002 uV 17:35:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.168 uVs 17:35:16 Integrated Voltage Measurement... 17:35:25 Voltage Offset Correction: v_off_ini = -3.930 uV, v_off_fin = 2.690 uV 17:35:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.411 uVs 17:35:25 Integrated Voltage Measurement... 17:35:34 Voltage Offset Correction: v_off_ini = -19.512 uV, v_off_fin = -18.390 uV 17:35:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -311.472 uVs 17:35:34 Integrated Voltage Measurement... 17:35:43 Voltage Offset Correction: v_off_ini = -6.542 uV, v_off_fin = -1.935 uV 17:35:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 307.364 uVs 17:35:43 Integrated Voltage Measurement... 17:35:52 Voltage Offset Correction: v_off_ini = -12.856 uV, v_off_fin = -15.394 uV 17:35:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -297.880 uVs 17:35:52 Integrated Voltage Measurement... 17:36:01 Voltage Offset Correction: v_off_ini = -24.257 uV, v_off_fin = -14.624 uV 17:36:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 301.615 uVs 17:36:06 I1Y Average and RMS of Measurements VT = -298.818 +- 9.058 uVs I1Y = -59.764 +- 1.812 uTm 17:36:11 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:36:13 Integrated Voltage Measurement... 17:36:22 Voltage Offset Correction: v_off_ini = -26.200 uV, v_off_fin = -29.927 uV 17:36:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -13.270 uVs 17:36:22 Integrated Voltage Measurement... 17:36:31 Voltage Offset Correction: v_off_ini = -21.761 uV, v_off_fin = -25.399 uV 17:36:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.886 uVs 17:36:31 Integrated Voltage Measurement... 17:36:40 Voltage Offset Correction: v_off_ini = -26.755 uV, v_off_fin = -33.648 uV 17:36:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.245 uVs 17:36:40 Integrated Voltage Measurement... 17:36:49 Voltage Offset Correction: v_off_ini = -36.796 uV, v_off_fin = -20.403 uV 17:36:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.211 uVs 17:36:49 Integrated Voltage Measurement... 17:36:58 Voltage Offset Correction: v_off_ini = -2.095 uV, v_off_fin = -24.624 uV 17:36:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -16.764 uVs 17:36:58 Integrated Voltage Measurement... 17:37:07 Voltage Offset Correction: v_off_ini = -23.901 uV, v_off_fin = -19.054 uV 17:37:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 10.536 uVs 17:37:10 I2X Average and RMS of Measurements VT = -21.319 +- 6.158 uVs I2X = 1.961 +- 0.567 uTm^2 17:37:15 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:37:17 Integrated Voltage Measurement... 17:37:26 Voltage Offset Correction: v_off_ini = -17.579 uV, v_off_fin = -42.702 uV 17:37:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.476 uVs 17:37:27 Integrated Voltage Measurement... 17:37:35 Voltage Offset Correction: v_off_ini = -44.112 uV, v_off_fin = -34.456 uV 17:37:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.341 uVs 17:37:36 Integrated Voltage Measurement... 17:37:44 Voltage Offset Correction: v_off_ini = -42.614 uV, v_off_fin = -36.328 uV 17:37:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.222 uVs 17:37:45 Integrated Voltage Measurement... 17:37:54 Voltage Offset Correction: v_off_ini = -30.503 uV, v_off_fin = -39.144 uV 17:37:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.894 uVs 17:37:54 Integrated Voltage Measurement... 17:38:03 Voltage Offset Correction: v_off_ini = -41.677 uV, v_off_fin = -50.704 uV 17:38:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.567 uVs 17:38:03 Integrated Voltage Measurement... 17:38:12 Voltage Offset Correction: v_off_ini = -45.827 uV, v_off_fin = -47.036 uV 17:38:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.113 uVs 17:38:14 I2Y Average and RMS of Measurements VT = -268.935 +- 11.665 uVs I2Y = -24.742 +- 1.073 uTm^2 17:38:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:38:23 Integrated Voltage Measurement... 17:38:32 Voltage Offset Correction: v_off_ini = -41.708 uV, v_off_fin = -46.294 uV 17:38:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.610 uVs 17:38:32 Integrated Voltage Measurement... 17:38:41 Voltage Offset Correction: v_off_ini = -49.812 uV, v_off_fin = -48.732 uV 17:38:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.358 uVs 17:38:41 Integrated Voltage Measurement... 17:38:50 Voltage Offset Correction: v_off_ini = -54.001 uV, v_off_fin = -53.870 uV 17:38:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -69.982 uVs 17:38:50 Integrated Voltage Measurement... 17:38:59 Voltage Offset Correction: v_off_ini = -61.484 uV, v_off_fin = -46.598 uV 17:38:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.681 uVs 17:38:59 Integrated Voltage Measurement... 17:39:08 Voltage Offset Correction: v_off_ini = -46.015 uV, v_off_fin = -42.972 uV 17:39:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.760 uVs 17:39:08 Integrated Voltage Measurement... 17:39:17 Voltage Offset Correction: v_off_ini = -47.967 uV, v_off_fin = -53.485 uV 17:39:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.063 uVs 17:39:21 I1X Average and RMS of Measurements VT = -53.742 +- 6.453 uVs I1X = 10.749 +- 1.291 uTm 17:39:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:39:28 Integrated Voltage Measurement... 17:39:37 Voltage Offset Correction: v_off_ini = -52.268 uV, v_off_fin = -65.453 uV 17:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -303.094 uVs 17:39:37 Integrated Voltage Measurement... 17:39:46 Voltage Offset Correction: v_off_ini = -57.701 uV, v_off_fin = -49.530 uV 17:39:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 284.235 uVs 17:39:46 Integrated Voltage Measurement... 17:39:55 Voltage Offset Correction: v_off_ini = -47.660 uV, v_off_fin = -60.493 uV 17:39:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.555 uVs 17:39:55 Integrated Voltage Measurement... 17:40:04 Voltage Offset Correction: v_off_ini = -52.446 uV, v_off_fin = -33.018 uV 17:40:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 285.459 uVs 17:40:04 Integrated Voltage Measurement... 17:40:13 Voltage Offset Correction: v_off_ini = -42.633 uV, v_off_fin = -60.876 uV 17:40:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.360 uVs 17:40:13 Integrated Voltage Measurement... 17:40:22 Voltage Offset Correction: v_off_ini = -59.423 uV, v_off_fin = -46.709 uV 17:40:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.614 uVs 17:40:26 I1Y Average and RMS of Measurements VT = -290.720 +- 3.696 uVs I1Y = -58.144 +- 0.739 uTm 17:40:31 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:40:34 Integrated Voltage Measurement... 17:40:43 Voltage Offset Correction: v_off_ini = -63.432 uV, v_off_fin = -60.354 uV 17:40:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.241 uVs 17:40:43 Integrated Voltage Measurement... 17:40:52 Voltage Offset Correction: v_off_ini = -49.128 uV, v_off_fin = -47.854 uV 17:40:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.176 uVs 17:40:52 Integrated Voltage Measurement... 17:41:01 Voltage Offset Correction: v_off_ini = -47.381 uV, v_off_fin = -53.292 uV 17:41:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.920 uVs 17:41:01 Integrated Voltage Measurement... 17:41:10 Voltage Offset Correction: v_off_ini = -46.843 uV, v_off_fin = -24.759 uV 17:41:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 0.719 uVs 17:41:10 Integrated Voltage Measurement... 17:41:19 Voltage Offset Correction: v_off_ini = -30.250 uV, v_off_fin = -40.119 uV 17:41:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -25.400 uVs 17:41:19 Integrated Voltage Measurement... 17:41:28 Voltage Offset Correction: v_off_ini = -34.013 uV, v_off_fin = -24.280 uV 17:41:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.463 uVs 17:41:30 I2X Average and RMS of Measurements VT = -19.320 +- 1.960 uVs I2X = 1.777 +- 0.180 uTm^2 17:41:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:41:38 Integrated Voltage Measurement... 17:41:47 Voltage Offset Correction: v_off_ini = -43.935 uV, v_off_fin = -54.401 uV 17:41:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.742 uVs 17:41:47 Integrated Voltage Measurement... 17:41:56 Voltage Offset Correction: v_off_ini = -38.596 uV, v_off_fin = -54.908 uV 17:41:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.448 uVs 17:41:56 Integrated Voltage Measurement... 17:42:05 Voltage Offset Correction: v_off_ini = -53.550 uV, v_off_fin = -49.121 uV 17:42:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.758 uVs 17:42:05 Integrated Voltage Measurement... 17:42:14 Voltage Offset Correction: v_off_ini = -49.413 uV, v_off_fin = -51.923 uV 17:42:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.846 uVs 17:42:14 Integrated Voltage Measurement... 17:42:23 Voltage Offset Correction: v_off_ini = -59.496 uV, v_off_fin = -66.005 uV 17:42:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.950 uVs 17:42:23 Integrated Voltage Measurement... 17:42:32 Voltage Offset Correction: v_off_ini = -42.514 uV, v_off_fin = -46.970 uV 17:42:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.099 uVs 17:42:34 I2Y Average and RMS of Measurements VT = -261.474 +- 13.508 uVs I2Y = -24.056 +- 1.243 uTm^2 17:42:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:42:43 Integrated Voltage Measurement... 17:42:52 Voltage Offset Correction: v_off_ini = -49.390 uV, v_off_fin = -58.356 uV 17:42:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.827 uVs 17:42:52 Integrated Voltage Measurement... 17:43:01 Voltage Offset Correction: v_off_ini = -35.606 uV, v_off_fin = -40.872 uV 17:43:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.663 uVs 17:43:01 Integrated Voltage Measurement... 17:43:10 Voltage Offset Correction: v_off_ini = -45.471 uV, v_off_fin = -49.113 uV 17:43:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.252 uVs 17:43:10 Integrated Voltage Measurement... 17:43:19 Voltage Offset Correction: v_off_ini = -37.576 uV, v_off_fin = -37.154 uV 17:43:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.617 uVs 17:43:19 Integrated Voltage Measurement... 17:43:28 Voltage Offset Correction: v_off_ini = -20.811 uV, v_off_fin = -35.531 uV 17:43:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.641 uVs 17:43:28 Integrated Voltage Measurement... 17:43:37 Voltage Offset Correction: v_off_ini = -47.965 uV, v_off_fin = -32.762 uV 17:43:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.386 uVs 17:43:42 I1X Average and RMS of Measurements VT = -59.064 +- 7.776 uVs I1X = 11.813 +- 1.555 uTm 17:43:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:43:48 Integrated Voltage Measurement... 17:43:57 Voltage Offset Correction: v_off_ini = -39.685 uV, v_off_fin = -50.843 uV 17:43:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.863 uVs 17:43:57 Integrated Voltage Measurement... 17:44:06 Voltage Offset Correction: v_off_ini = -46.699 uV, v_off_fin = -26.332 uV 17:44:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 280.537 uVs 17:44:06 Integrated Voltage Measurement... 17:44:15 Voltage Offset Correction: v_off_ini = -35.081 uV, v_off_fin = -55.303 uV 17:44:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.798 uVs 17:44:15 Integrated Voltage Measurement... 17:44:24 Voltage Offset Correction: v_off_ini = -26.834 uV, v_off_fin = -33.396 uV 17:44:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.482 uVs 17:44:24 Integrated Voltage Measurement... 17:44:33 Voltage Offset Correction: v_off_ini = -39.562 uV, v_off_fin = -41.110 uV 17:44:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.962 uVs 17:44:33 Integrated Voltage Measurement... 17:44:42 Voltage Offset Correction: v_off_ini = -28.564 uV, v_off_fin = -16.083 uV 17:44:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 294.285 uVs 17:44:46 I1Y Average and RMS of Measurements VT = -279.821 +- 6.303 uVs I1Y = -55.964 +- 1.261 uTm 17:44:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:44:54 Integrated Voltage Measurement... 17:45:03 Voltage Offset Correction: v_off_ini = -30.014 uV, v_off_fin = -37.326 uV 17:45:03 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -37.735 uVs 17:45:03 Integrated Voltage Measurement... 17:45:12 Voltage Offset Correction: v_off_ini = -40.795 uV, v_off_fin = -17.165 uV 17:45:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 53.250 uVs 17:45:12 Integrated Voltage Measurement... 17:45:21 Voltage Offset Correction: v_off_ini = -25.160 uV, v_off_fin = -35.863 uV 17:45:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.493 uVs 17:45:21 Integrated Voltage Measurement... 17:45:30 Voltage Offset Correction: v_off_ini = -27.476 uV, v_off_fin = -10.828 uV 17:45:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.166 uVs 17:45:30 Integrated Voltage Measurement... 17:45:39 Voltage Offset Correction: v_off_ini = -10.828 uV, v_off_fin = -36.091 uV 17:45:39 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -37.258 uVs 17:45:39 Integrated Voltage Measurement... 17:45:48 Voltage Offset Correction: v_off_ini = -30.108 uV, v_off_fin = -25.718 uV 17:45:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.669 uVs 17:45:51 I2X Average and RMS of Measurements VT = -35.928 +- 6.994 uVs I2X = 3.305 +- 0.643 uTm^2 17:45:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:45:58 Integrated Voltage Measurement... 17:46:07 Voltage Offset Correction: v_off_ini = -17.842 uV, v_off_fin = -36.575 uV 17:46:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.374 uVs 17:46:07 Integrated Voltage Measurement... 17:46:16 Voltage Offset Correction: v_off_ini = -36.169 uV, v_off_fin = -35.321 uV 17:46:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.108 uVs 17:46:16 Integrated Voltage Measurement... 17:46:25 Voltage Offset Correction: v_off_ini = -43.771 uV, v_off_fin = -41.257 uV 17:46:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.761 uVs 17:46:25 Integrated Voltage Measurement... 17:46:34 Voltage Offset Correction: v_off_ini = -32.986 uV, v_off_fin = -36.259 uV 17:46:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.876 uVs 17:46:34 Integrated Voltage Measurement... 17:46:43 Voltage Offset Correction: v_off_ini = -34.428 uV, v_off_fin = -22.636 uV 17:46:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.468 uVs 17:46:43 Integrated Voltage Measurement... 17:46:52 Voltage Offset Correction: v_off_ini = -26.963 uV, v_off_fin = -29.801 uV 17:46:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.706 uVs 17:46:55 I2Y Average and RMS of Measurements VT = -252.715 +- 11.047 uVs I2Y = -23.250 +- 1.016 uTm^2 17:46:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:47:04 Integrated Voltage Measurement... 17:47:13 Voltage Offset Correction: v_off_ini = -35.861 uV, v_off_fin = -36.091 uV 17:47:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.608 uVs 17:47:13 Integrated Voltage Measurement... 17:47:22 Voltage Offset Correction: v_off_ini = -35.907 uV, v_off_fin = -31.916 uV 17:47:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.439 uVs 17:47:22 Integrated Voltage Measurement... 17:47:31 Voltage Offset Correction: v_off_ini = -51.133 uV, v_off_fin = -58.090 uV 17:47:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -93.454 uVs 17:47:31 Integrated Voltage Measurement... 17:47:40 Voltage Offset Correction: v_off_ini = -39.485 uV, v_off_fin = -40.997 uV 17:47:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.276 uVs 17:47:40 Integrated Voltage Measurement... 17:47:49 Voltage Offset Correction: v_off_ini = -56.166 uV, v_off_fin = -64.092 uV 17:47:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.964 uVs 17:47:49 Integrated Voltage Measurement... 17:47:58 Voltage Offset Correction: v_off_ini = -49.069 uV, v_off_fin = -43.839 uV 17:47:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.153 uVs 17:48:02 I1X Average and RMS of Measurements VT = -66.816 +- 3.322 uVs I1X = 13.363 +- 0.664 uTm 17:48:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:48:09 Integrated Voltage Measurement... 17:48:18 Voltage Offset Correction: v_off_ini = -51.775 uV, v_off_fin = -63.595 uV 17:48:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -259.738 uVs 17:48:18 Integrated Voltage Measurement... 17:48:27 Voltage Offset Correction: v_off_ini = -31.311 uV, v_off_fin = -15.088 uV 17:48:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.552 uVs 17:48:27 Integrated Voltage Measurement... 17:48:36 Voltage Offset Correction: v_off_ini = -15.939 uV, v_off_fin = -55.708 uV 17:48:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.262 uVs 17:48:36 Integrated Voltage Measurement... 17:48:45 Voltage Offset Correction: v_off_ini = -26.164 uV, v_off_fin = -15.702 uV 17:48:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.616 uVs 17:48:45 Integrated Voltage Measurement... 17:48:54 Voltage Offset Correction: v_off_ini = -48.868 uV, v_off_fin = -50.630 uV 17:48:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.013 uVs 17:48:54 Integrated Voltage Measurement... 17:49:03 Voltage Offset Correction: v_off_ini = -46.043 uV, v_off_fin = -32.164 uV 17:49:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.932 uVs 17:49:07 I1Y Average and RMS of Measurements VT = -272.186 +- 4.003 uVs I1Y = -54.438 +- 0.800 uTm 17:49:12 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:49:14 Integrated Voltage Measurement... 17:49:23 Voltage Offset Correction: v_off_ini = -50.467 uV, v_off_fin = -42.704 uV 17:49:23 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -40.648 uVs 17:49:23 Integrated Voltage Measurement... 17:49:32 Voltage Offset Correction: v_off_ini = -38.836 uV, v_off_fin = -22.983 uV 17:49:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.888 uVs 17:49:33 Integrated Voltage Measurement... 17:49:42 Voltage Offset Correction: v_off_ini = -40.836 uV, v_off_fin = -49.897 uV 17:49:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.739 uVs 17:49:42 Integrated Voltage Measurement... 17:49:51 Voltage Offset Correction: v_off_ini = -38.570 uV, v_off_fin = -38.824 uV 17:49:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.910 uVs 17:49:51 Integrated Voltage Measurement... 17:50:00 Voltage Offset Correction: v_off_ini = -30.801 uV, v_off_fin = -45.053 uV 17:50:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.721 uVs 17:50:00 Integrated Voltage Measurement... 17:50:09 Voltage Offset Correction: v_off_ini = -12.532 uV, v_off_fin = -11.033 uV 17:50:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 37.266 uVs 17:50:11 I2X Average and RMS of Measurements VT = -42.029 +- 10.480 uVs I2X = 3.867 +- 0.964 uTm^2 17:50:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:50:19 Integrated Voltage Measurement... 17:50:28 Voltage Offset Correction: v_off_ini = -24.318 uV, v_off_fin = -35.208 uV 17:50:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.595 uVs 17:50:28 Integrated Voltage Measurement... 17:50:37 Voltage Offset Correction: v_off_ini = -37.219 uV, v_off_fin = -45.782 uV 17:50:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.178 uVs 17:50:37 Integrated Voltage Measurement... 17:50:46 Voltage Offset Correction: v_off_ini = -41.449 uV, v_off_fin = -34.515 uV 17:50:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.347 uVs 17:50:46 Integrated Voltage Measurement... 17:50:55 Voltage Offset Correction: v_off_ini = -40.060 uV, v_off_fin = -34.731 uV 17:50:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.427 uVs 17:50:55 Integrated Voltage Measurement... 17:51:04 Voltage Offset Correction: v_off_ini = -37.466 uV, v_off_fin = -34.495 uV 17:51:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.206 uVs 17:51:04 Integrated Voltage Measurement... 17:51:13 Voltage Offset Correction: v_off_ini = -49.474 uV, v_off_fin = -30.151 uV 17:51:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.333 uVs 17:51:15 I2Y Average and RMS of Measurements VT = -245.181 +- 3.328 uVs I2Y = -22.557 +- 0.306 uTm^2 17:51:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:51:24 Integrated Voltage Measurement... 17:51:33 Voltage Offset Correction: v_off_ini = -37.067 uV, v_off_fin = -43.878 uV 17:51:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.677 uVs 17:51:33 Integrated Voltage Measurement... 17:51:42 Voltage Offset Correction: v_off_ini = -28.562 uV, v_off_fin = -33.676 uV 17:51:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.056 uVs 17:51:42 Integrated Voltage Measurement... 17:51:51 Voltage Offset Correction: v_off_ini = -42.419 uV, v_off_fin = -33.957 uV 17:51:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -91.280 uVs 17:51:51 Integrated Voltage Measurement... 17:52:00 Voltage Offset Correction: v_off_ini = -30.348 uV, v_off_fin = -42.250 uV 17:52:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.050 uVs 17:52:00 Integrated Voltage Measurement... 17:52:09 Voltage Offset Correction: v_off_ini = -41.677 uV, v_off_fin = -50.646 uV 17:52:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -86.543 uVs 17:52:09 Integrated Voltage Measurement... 17:52:18 Voltage Offset Correction: v_off_ini = -43.097 uV, v_off_fin = -42.105 uV 17:52:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 77.828 uVs 17:52:22 I1X Average and RMS of Measurements VT = -66.572 +- 13.217 uVs I1X = 13.316 +- 2.644 uTm 17:52:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:52:29 Integrated Voltage Measurement... 17:52:38 Voltage Offset Correction: v_off_ini = -68.744 uV, v_off_fin = -59.021 uV 17:52:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.180 uVs 17:52:38 Integrated Voltage Measurement... 17:52:47 Voltage Offset Correction: v_off_ini = -64.724 uV, v_off_fin = -54.218 uV 17:52:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.111 uVs 17:52:47 Integrated Voltage Measurement... 17:52:56 Voltage Offset Correction: v_off_ini = -39.635 uV, v_off_fin = -46.074 uV 17:52:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.513 uVs 17:52:56 Integrated Voltage Measurement... 17:53:05 Voltage Offset Correction: v_off_ini = -59.721 uV, v_off_fin = -41.712 uV 17:53:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.957 uVs 17:53:05 Integrated Voltage Measurement... 17:53:14 Voltage Offset Correction: v_off_ini = -60.567 uV, v_off_fin = -65.344 uV 17:53:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.567 uVs 17:53:14 Integrated Voltage Measurement... 17:53:23 Voltage Offset Correction: v_off_ini = -55.131 uV, v_off_fin = -38.059 uV 17:53:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.438 uVs 17:53:27 I1Y Average and RMS of Measurements VT = -269.961 +- 2.312 uVs I1Y = -53.992 +- 0.462 uTm 17:53:32 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:53:35 Integrated Voltage Measurement... 17:53:44 Voltage Offset Correction: v_off_ini = -40.146 uV, v_off_fin = -45.226 uV 17:53:44 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -44.924 uVs 17:53:44 Integrated Voltage Measurement... 17:53:53 Voltage Offset Correction: v_off_ini = -31.225 uV, v_off_fin = -39.338 uV 17:53:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.578 uVs 17:53:53 Integrated Voltage Measurement... 17:54:02 Voltage Offset Correction: v_off_ini = -41.054 uV, v_off_fin = -30.862 uV 17:54:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.259 uVs 17:54:02 Integrated Voltage Measurement... 17:54:11 Voltage Offset Correction: v_off_ini = -26.740 uV, v_off_fin = -34.171 uV 17:54:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.274 uVs 17:54:11 Integrated Voltage Measurement... 17:54:20 Voltage Offset Correction: v_off_ini = -41.503 uV, v_off_fin = -48.933 uV 17:54:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.139 uVs 17:54:20 Integrated Voltage Measurement... 17:54:29 Voltage Offset Correction: v_off_ini = -28.773 uV, v_off_fin = -17.901 uV 17:54:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.822 uVs 17:54:31 I2X Average and RMS of Measurements VT = -62.999 +- 8.667 uVs I2X = 5.796 +- 0.797 uTm^2 17:54:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:54:39 Integrated Voltage Measurement... 17:54:48 Voltage Offset Correction: v_off_ini = -24.472 uV, v_off_fin = -37.967 uV 17:54:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.743 uVs 17:54:48 Integrated Voltage Measurement... 17:54:57 Voltage Offset Correction: v_off_ini = -31.340 uV, v_off_fin = -29.421 uV 17:54:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.158 uVs 17:54:57 Integrated Voltage Measurement... 17:55:06 Voltage Offset Correction: v_off_ini = -33.652 uV, v_off_fin = -31.600 uV 17:55:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.188 uVs 17:55:06 Integrated Voltage Measurement... 17:55:15 Voltage Offset Correction: v_off_ini = -31.520 uV, v_off_fin = -39.130 uV 17:55:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.952 uVs 17:55:15 Integrated Voltage Measurement... 17:55:24 Voltage Offset Correction: v_off_ini = -47.301 uV, v_off_fin = -28.832 uV 17:55:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.855 uVs 17:55:24 Integrated Voltage Measurement... 17:55:33 Voltage Offset Correction: v_off_ini = -31.491 uV, v_off_fin = -24.573 uV 17:55:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.957 uVs 17:55:36 I2Y Average and RMS of Measurements VT = -246.142 +- 8.824 uVs I2Y = -22.645 +- 0.812 uTm^2 17:55:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:55:48 Integrated Voltage Measurement... 17:55:57 Voltage Offset Correction: v_off_ini = -17.010 uV, v_off_fin = -28.212 uV 17:55:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -53.389 uVs 17:55:57 Integrated Voltage Measurement... 17:56:06 Voltage Offset Correction: v_off_ini = -15.972 uV, v_off_fin = -14.061 uV 17:56:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 45.996 uVs 17:56:06 Integrated Voltage Measurement... 17:56:15 Voltage Offset Correction: v_off_ini = -31.656 uV, v_off_fin = -30.503 uV 17:56:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.999 uVs 17:56:15 Integrated Voltage Measurement... 17:56:24 Voltage Offset Correction: v_off_ini = -19.181 uV, v_off_fin = -26.520 uV 17:56:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.987 uVs 17:56:24 Integrated Voltage Measurement... 17:56:33 Voltage Offset Correction: v_off_ini = -17.379 uV, v_off_fin = -26.490 uV 17:56:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.662 uVs 17:56:33 Integrated Voltage Measurement... 17:56:42 Voltage Offset Correction: v_off_ini = -13.561 uV, v_off_fin = -23.123 uV 17:56:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.143 uVs 17:56:46 I1X Average and RMS of Measurements VT = -41.030 +- 6.204 uVs I1X = 8.207 +- 1.242 uTm 17:56:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:56:53 Integrated Voltage Measurement... 17:57:02 Voltage Offset Correction: v_off_ini = -39.524 uV, v_off_fin = -45.654 uV 17:57:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.830 uVs 17:57:02 Integrated Voltage Measurement... 17:57:10 Voltage Offset Correction: v_off_ini = -32.318 uV, v_off_fin = -18.832 uV 17:57:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.021 uVs 17:57:11 Integrated Voltage Measurement... 17:57:19 Voltage Offset Correction: v_off_ini = -40.739 uV, v_off_fin = -51.620 uV 17:57:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.442 uVs 17:57:20 Integrated Voltage Measurement... 17:57:28 Voltage Offset Correction: v_off_ini = -30.499 uV, v_off_fin = -16.865 uV 17:57:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.792 uVs 17:57:29 Integrated Voltage Measurement... 17:57:37 Voltage Offset Correction: v_off_ini = -43.777 uV, v_off_fin = -47.319 uV 17:57:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.581 uVs 17:57:38 Integrated Voltage Measurement... 17:57:46 Voltage Offset Correction: v_off_ini = -32.424 uV, v_off_fin = -14.898 uV 17:57:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.790 uVs 17:57:51 I1Y Average and RMS of Measurements VT = -263.576 +- 8.099 uVs I1Y = -52.715 +- 1.620 uTm 17:57:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:57:56 Integrated Voltage Measurement... 17:58:05 Voltage Offset Correction: v_off_ini = -36.058 uV, v_off_fin = -38.743 uV 17:58:05 Integrated Voltage Measurement dXYus = -0.9998 mm, dXYds = 0.0000 mm dXY = -0.9998 mm VT = -40.071 uVs 17:58:05 Integrated Voltage Measurement... 17:58:14 Voltage Offset Correction: v_off_ini = -54.368 uV, v_off_fin = -39.108 uV 17:58:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.990 uVs 17:58:14 Integrated Voltage Measurement... 17:58:23 Voltage Offset Correction: v_off_ini = -34.690 uV, v_off_fin = -70.995 uV 17:58:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.801 uVs 17:58:23 Integrated Voltage Measurement... 17:58:32 Voltage Offset Correction: v_off_ini = -49.646 uV, v_off_fin = -35.978 uV 17:58:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 18.977 uVs 17:58:32 Integrated Voltage Measurement... 17:58:41 Voltage Offset Correction: v_off_ini = -56.551 uV, v_off_fin = -56.484 uV 17:58:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.933 uVs 17:58:41 Integrated Voltage Measurement... 17:58:50 Voltage Offset Correction: v_off_ini = -48.624 uV, v_off_fin = -35.645 uV 17:58:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 15.269 uVs 17:58:52 I2X Average and RMS of Measurements VT = -33.174 +- 4.819 uVs I2X = 3.052 +- 0.443 uTm^2 17:58:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:58:57 Integrated Voltage Measurement... 17:59:06 Voltage Offset Correction: v_off_ini = -47.405 uV, v_off_fin = -43.993 uV 17:59:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.995 uVs 17:59:06 Integrated Voltage Measurement... 17:59:15 Voltage Offset Correction: v_off_ini = -46.296 uV, v_off_fin = -57.987 uV 17:59:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.588 uVs 17:59:15 Integrated Voltage Measurement... 17:59:24 Voltage Offset Correction: v_off_ini = -49.705 uV, v_off_fin = -56.797 uV 17:59:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.659 uVs 17:59:24 Integrated Voltage Measurement... 17:59:33 Voltage Offset Correction: v_off_ini = -55.287 uV, v_off_fin = -46.372 uV 17:59:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.181 uVs 17:59:34 Integrated Voltage Measurement... 17:59:42 Voltage Offset Correction: v_off_ini = -57.005 uV, v_off_fin = -65.068 uV 17:59:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.264 uVs 17:59:43 Integrated Voltage Measurement... 17:59:51 Voltage Offset Correction: v_off_ini = -43.388 uV, v_off_fin = -43.079 uV 17:59:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.706 uVs 17:59:54 I2Y Average and RMS of Measurements VT = -240.399 +- 1.809 uVs I2Y = -22.117 +- 0.166 uTm^2 17:59:58 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:00:02 Integrated Voltage Measurement... 18:00:11 Voltage Offset Correction: v_off_ini = -56.840 uV, v_off_fin = -63.144 uV 18:00:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -26.142 uVs 18:00:11 Integrated Voltage Measurement... 18:00:20 Voltage Offset Correction: v_off_ini = -52.826 uV, v_off_fin = -60.503 uV 18:00:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.656 uVs 18:00:20 Integrated Voltage Measurement... 18:00:29 Voltage Offset Correction: v_off_ini = -72.587 uV, v_off_fin = -78.124 uV 18:00:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.931 uVs 18:00:29 Integrated Voltage Measurement... 18:00:38 Voltage Offset Correction: v_off_ini = -72.502 uV, v_off_fin = -74.328 uV 18:00:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.003 uVs 18:00:38 Integrated Voltage Measurement... 18:00:47 Voltage Offset Correction: v_off_ini = -88.571 uV, v_off_fin = -90.480 uV 18:00:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.991 uVs 18:00:47 Integrated Voltage Measurement... 18:00:56 Voltage Offset Correction: v_off_ini = -54.291 uV, v_off_fin = -72.610 uV 18:00:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.374 uVs 18:01:00 I1X Average and RMS of Measurements VT = -40.016 +- 4.142 uVs I1X = 8.003 +- 0.828 uTm 18:01:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:01:07 Integrated Voltage Measurement... 18:01:16 Voltage Offset Correction: v_off_ini = -75.937 uV, v_off_fin = -81.841 uV 18:01:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.948 uVs 18:01:16 Integrated Voltage Measurement... 18:01:25 Voltage Offset Correction: v_off_ini = -68.359 uV, v_off_fin = -62.538 uV 18:01:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.157 uVs 18:01:25 Integrated Voltage Measurement... 18:01:34 Voltage Offset Correction: v_off_ini = -80.655 uV, v_off_fin = -91.163 uV 18:01:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.090 uVs 18:01:34 Integrated Voltage Measurement... 18:01:43 Voltage Offset Correction: v_off_ini = -69.102 uV, v_off_fin = -61.770 uV 18:01:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 288.097 uVs 18:01:43 Integrated Voltage Measurement... 18:01:52 Voltage Offset Correction: v_off_ini = -79.856 uV, v_off_fin = -98.854 uV 18:01:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.606 uVs 18:01:52 Integrated Voltage Measurement... 18:02:01 Voltage Offset Correction: v_off_ini = -90.943 uV, v_off_fin = -89.156 uV 18:02:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.167 uVs 18:02:05 I1Y Average and RMS of Measurements VT = -281.011 +- 1.164 uVs I1Y = -56.202 +- 0.233 uTm 18:02:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:02:10 Integrated Voltage Measurement... 18:02:19 Voltage Offset Correction: v_off_ini = -75.749 uV, v_off_fin = -96.412 uV 18:02:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -46.599 uVs 18:02:19 Integrated Voltage Measurement... 18:02:28 Voltage Offset Correction: v_off_ini = -93.776 uV, v_off_fin = -80.697 uV 18:02:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.757 uVs 18:02:28 Integrated Voltage Measurement... 18:02:37 Voltage Offset Correction: v_off_ini = -71.725 uV, v_off_fin = -92.974 uV 18:02:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.590 uVs 18:02:37 Integrated Voltage Measurement... 18:02:46 Voltage Offset Correction: v_off_ini = -69.011 uV, v_off_fin = -75.440 uV 18:02:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 1.059 uVs 18:02:46 Integrated Voltage Measurement... 18:02:55 Voltage Offset Correction: v_off_ini = -96.784 uV, v_off_fin = -101.579 uV 18:02:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.878 uVs 18:02:55 Integrated Voltage Measurement... 18:03:04 Voltage Offset Correction: v_off_ini = -85.991 uV, v_off_fin = -94.944 uV 18:03:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.829 uVs 18:03:07 I2X Average and RMS of Measurements VT = -35.786 +- 11.213 uVs I2X = 3.292 +- 1.032 uTm^2 18:03:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:03:12 Integrated Voltage Measurement... 18:03:21 Voltage Offset Correction: v_off_ini = -71.940 uV, v_off_fin = -88.533 uV 18:03:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.132 uVs 18:03:21 Integrated Voltage Measurement... 18:03:30 Voltage Offset Correction: v_off_ini = -76.433 uV, v_off_fin = -93.968 uV 18:03:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.672 uVs 18:03:30 Integrated Voltage Measurement... 18:03:39 Voltage Offset Correction: v_off_ini = -78.490 uV, v_off_fin = -68.581 uV 18:03:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.025 uVs 18:03:39 Integrated Voltage Measurement... 18:03:48 Voltage Offset Correction: v_off_ini = -63.422 uV, v_off_fin = -62.984 uV 18:03:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.510 uVs 18:03:48 Integrated Voltage Measurement... 18:03:57 Voltage Offset Correction: v_off_ini = -68.461 uV, v_off_fin = -72.139 uV 18:03:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.086 uVs 18:03:57 Integrated Voltage Measurement... 18:04:06 Voltage Offset Correction: v_off_ini = -80.132 uV, v_off_fin = -74.831 uV 18:04:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.955 uVs 18:04:08 I2Y Average and RMS of Measurements VT = -250.064 +- 1.919 uVs I2Y = -23.006 +- 0.177 uTm^2 18:04:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:04:17 Integrated Voltage Measurement... 18:04:26 Voltage Offset Correction: v_off_ini = -81.388 uV, v_off_fin = -90.177 uV 18:04:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -66.950 uVs 18:04:26 Integrated Voltage Measurement... 18:04:35 Voltage Offset Correction: v_off_ini = -71.899 uV, v_off_fin = -83.564 uV 18:04:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.618 uVs 18:04:35 Integrated Voltage Measurement... 18:04:44 Voltage Offset Correction: v_off_ini = -89.796 uV, v_off_fin = -77.781 uV 18:04:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.127 uVs 18:04:44 Integrated Voltage Measurement... 18:04:53 Voltage Offset Correction: v_off_ini = -87.047 uV, v_off_fin = -82.663 uV 18:04:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.973 uVs 18:04:53 Integrated Voltage Measurement... 18:05:02 Voltage Offset Correction: v_off_ini = -72.900 uV, v_off_fin = -91.790 uV 18:05:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.162 uVs 18:05:02 Integrated Voltage Measurement... 18:05:11 Voltage Offset Correction: v_off_ini = -79.242 uV, v_off_fin = -85.060 uV 18:05:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.237 uVs 18:05:15 I1X Average and RMS of Measurements VT = -57.511 +- 1.339 uVs I1X = 11.503 +- 0.268 uTm 18:05:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:05:22 Integrated Voltage Measurement... 18:05:31 Voltage Offset Correction: v_off_ini = -85.400 uV, v_off_fin = -106.655 uV 18:05:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.425 uVs 18:05:31 Integrated Voltage Measurement... 18:05:40 Voltage Offset Correction: v_off_ini = -99.266 uV, v_off_fin = -83.310 uV 18:05:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 285.124 uVs 18:05:40 Integrated Voltage Measurement... 18:05:49 Voltage Offset Correction: v_off_ini = -97.499 uV, v_off_fin = -100.206 uV 18:05:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.011 uVs 18:05:49 Integrated Voltage Measurement... 18:05:58 Voltage Offset Correction: v_off_ini = -82.283 uV, v_off_fin = -75.560 uV 18:05:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.985 uVs 18:05:58 Integrated Voltage Measurement... 18:06:07 Voltage Offset Correction: v_off_ini = -87.123 uV, v_off_fin = -105.100 uV 18:06:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.296 uVs 18:06:07 Integrated Voltage Measurement... 18:06:16 Voltage Offset Correction: v_off_ini = -89.528 uV, v_off_fin = -76.681 uV 18:06:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.135 uVs 18:06:20 I1Y Average and RMS of Measurements VT = -275.496 +- 3.014 uVs I1Y = -55.099 +- 0.603 uTm 18:06:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:06:25 Integrated Voltage Measurement... 18:06:34 Voltage Offset Correction: v_off_ini = -78.627 uV, v_off_fin = -84.971 uV 18:06:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.370 uVs 18:06:34 Integrated Voltage Measurement... 18:06:43 Voltage Offset Correction: v_off_ini = -91.705 uV, v_off_fin = -78.517 uV 18:06:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.288 uVs 18:06:43 Integrated Voltage Measurement... 18:06:52 Voltage Offset Correction: v_off_ini = -83.945 uV, v_off_fin = -83.246 uV 18:06:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.479 uVs 18:06:52 Integrated Voltage Measurement... 18:07:01 Voltage Offset Correction: v_off_ini = -78.276 uV, v_off_fin = -67.723 uV 18:07:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.383 uVs 18:07:01 Integrated Voltage Measurement... 18:07:10 Voltage Offset Correction: v_off_ini = -74.495 uV, v_off_fin = -79.740 uV 18:07:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.687 uVs 18:07:10 Integrated Voltage Measurement... 18:07:19 Voltage Offset Correction: v_off_ini = -65.599 uV, v_off_fin = -76.596 uV 18:07:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 25.069 uVs 18:07:22 I2X Average and RMS of Measurements VT = -35.213 +- 10.736 uVs I2X = 3.240 +- 0.988 uTm^2 18:07:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:07:27 Integrated Voltage Measurement... 18:07:36 Voltage Offset Correction: v_off_ini = -70.526 uV, v_off_fin = -77.173 uV 18:07:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.239 uVs 18:07:36 Integrated Voltage Measurement... 18:07:45 Voltage Offset Correction: v_off_ini = -87.332 uV, v_off_fin = -81.412 uV 18:07:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.043 uVs 18:07:45 Integrated Voltage Measurement... 18:07:54 Voltage Offset Correction: v_off_ini = -78.658 uV, v_off_fin = -72.053 uV 18:07:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.298 uVs 18:07:54 Integrated Voltage Measurement... 18:08:03 Voltage Offset Correction: v_off_ini = -70.050 uV, v_off_fin = -68.496 uV 18:08:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.155 uVs 18:08:03 Integrated Voltage Measurement... 18:08:12 Voltage Offset Correction: v_off_ini = -84.122 uV, v_off_fin = -72.809 uV 18:08:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.243 uVs 18:08:12 Integrated Voltage Measurement... 18:08:21 Voltage Offset Correction: v_off_ini = -91.683 uV, v_off_fin = -93.475 uV 18:08:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.959 uVs 18:08:23 I2Y Average and RMS of Measurements VT = -253.323 +- 0.666 uVs I2Y = -23.306 +- 0.061 uTm^2 18:08:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:08:32 Integrated Voltage Measurement... 18:08:41 Voltage Offset Correction: v_off_ini = -86.816 uV, v_off_fin = -84.218 uV 18:08:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -62.842 uVs 18:08:41 Integrated Voltage Measurement... 18:08:50 Voltage Offset Correction: v_off_ini = -88.437 uV, v_off_fin = -95.872 uV 18:08:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.213 uVs 18:08:50 Integrated Voltage Measurement... 18:08:59 Voltage Offset Correction: v_off_ini = -81.495 uV, v_off_fin = -84.805 uV 18:08:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.813 uVs 18:08:59 Integrated Voltage Measurement... 18:09:08 Voltage Offset Correction: v_off_ini = -74.343 uV, v_off_fin = -73.709 uV 18:09:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.195 uVs 18:09:08 Integrated Voltage Measurement... 18:09:17 Voltage Offset Correction: v_off_ini = -74.764 uV, v_off_fin = -83.291 uV 18:09:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.792 uVs 18:09:17 Integrated Voltage Measurement... 18:09:26 Voltage Offset Correction: v_off_ini = -70.946 uV, v_off_fin = -70.601 uV 18:09:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.565 uVs 18:09:30 I1X Average and RMS of Measurements VT = -62.570 +- 6.636 uVs I1X = 12.514 +- 1.327 uTm 18:09:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:09:37 Integrated Voltage Measurement... 18:09:46 Voltage Offset Correction: v_off_ini = -79.108 uV, v_off_fin = -82.803 uV 18:09:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -273.199 uVs 18:09:46 Integrated Voltage Measurement... 18:09:55 Voltage Offset Correction: v_off_ini = -78.540 uV, v_off_fin = -76.384 uV 18:09:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.900 uVs 18:09:55 Integrated Voltage Measurement... 18:10:04 Voltage Offset Correction: v_off_ini = -78.503 uV, v_off_fin = -91.644 uV 18:10:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -289.980 uVs 18:10:04 Integrated Voltage Measurement... 18:10:13 Voltage Offset Correction: v_off_ini = -84.880 uV, v_off_fin = -81.401 uV 18:10:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 294.586 uVs 18:10:13 Integrated Voltage Measurement... 18:10:22 Voltage Offset Correction: v_off_ini = -77.409 uV, v_off_fin = -91.681 uV 18:10:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -297.631 uVs 18:10:22 Integrated Voltage Measurement... 18:10:31 Voltage Offset Correction: v_off_ini = -75.738 uV, v_off_fin = -75.539 uV 18:10:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.526 uVs 18:10:35 I1Y Average and RMS of Measurements VT = -286.804 +- 5.940 uVs I1Y = -57.361 +- 1.188 uTm 18:10:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:10:40 Integrated Voltage Measurement... 18:10:49 Voltage Offset Correction: v_off_ini = -87.710 uV, v_off_fin = -115.158 uV 18:10:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.646 uVs 18:10:49 Integrated Voltage Measurement... 18:10:58 Voltage Offset Correction: v_off_ini = -90.384 uV, v_off_fin = -90.411 uV 18:10:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.051 uVs 18:10:58 Integrated Voltage Measurement... 18:11:07 Voltage Offset Correction: v_off_ini = -89.349 uV, v_off_fin = -109.540 uV 18:11:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.309 uVs 18:11:07 Integrated Voltage Measurement... 18:11:16 Voltage Offset Correction: v_off_ini = -87.445 uV, v_off_fin = -82.819 uV 18:11:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.354 uVs 18:11:16 Integrated Voltage Measurement... 18:11:25 Voltage Offset Correction: v_off_ini = -98.679 uV, v_off_fin = -111.744 uV 18:11:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.380 uVs 18:11:25 Integrated Voltage Measurement... 18:11:34 Voltage Offset Correction: v_off_ini = -86.922 uV, v_off_fin = -87.764 uV 18:11:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.460 uVs 18:11:37 I2X Average and RMS of Measurements VT = -42.533 +- 4.919 uVs I2X = 3.913 +- 0.453 uTm^2 18:11:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:11:42 Integrated Voltage Measurement... 18:11:51 Voltage Offset Correction: v_off_ini = -92.159 uV, v_off_fin = -86.639 uV 18:11:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.613 uVs 18:11:51 Integrated Voltage Measurement... 18:12:00 Voltage Offset Correction: v_off_ini = -95.091 uV, v_off_fin = -102.213 uV 18:12:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.345 uVs 18:12:00 Integrated Voltage Measurement... 18:12:09 Voltage Offset Correction: v_off_ini = -94.173 uV, v_off_fin = -86.304 uV 18:12:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.163 uVs 18:12:09 Integrated Voltage Measurement... 18:12:18 Voltage Offset Correction: v_off_ini = -95.078 uV, v_off_fin = -88.115 uV 18:12:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.681 uVs 18:12:18 Integrated Voltage Measurement... 18:12:27 Voltage Offset Correction: v_off_ini = -86.328 uV, v_off_fin = -91.567 uV 18:12:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.044 uVs 18:12:27 Integrated Voltage Measurement... 18:12:36 Voltage Offset Correction: v_off_ini = -97.474 uV, v_off_fin = -95.697 uV 18:12:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.567 uVs 18:12:38 I2Y Average and RMS of Measurements VT = -257.069 +- 7.076 uVs I2Y = -23.650 +- 0.651 uTm^2 18:12:42 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:12:47 Integrated Voltage Measurement... 18:12:56 Voltage Offset Correction: v_off_ini = -94.882 uV, v_off_fin = -92.650 uV 18:12:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -53.319 uVs 18:12:56 Integrated Voltage Measurement... 18:13:05 Voltage Offset Correction: v_off_ini = -96.113 uV, v_off_fin = -82.097 uV 18:13:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.652 uVs 18:13:05 Integrated Voltage Measurement... 18:13:14 Voltage Offset Correction: v_off_ini = -73.990 uV, v_off_fin = -98.632 uV 18:13:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.805 uVs 18:13:14 Integrated Voltage Measurement... 18:13:23 Voltage Offset Correction: v_off_ini = -76.877 uV, v_off_fin = -77.104 uV 18:13:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.175 uVs 18:13:23 Integrated Voltage Measurement... 18:13:32 Voltage Offset Correction: v_off_ini = -85.269 uV, v_off_fin = -86.675 uV 18:13:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.797 uVs 18:13:32 Integrated Voltage Measurement... 18:13:41 Voltage Offset Correction: v_off_ini = -64.270 uV, v_off_fin = -91.080 uV 18:13:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.083 uVs 18:13:45 I1X Average and RMS of Measurements VT = -50.305 +- 5.529 uVs I1X = 10.061 +- 1.106 uTm 18:13:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:13:52 Integrated Voltage Measurement... 18:14:00 Voltage Offset Correction: v_off_ini = -74.113 uV, v_off_fin = -95.251 uV 18:14:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -284.435 uVs 18:14:01 Integrated Voltage Measurement... 18:14:09 Voltage Offset Correction: v_off_ini = -64.203 uV, v_off_fin = -56.157 uV 18:14:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 295.831 uVs 18:14:09 Integrated Voltage Measurement... 18:14:18 Voltage Offset Correction: v_off_ini = -79.075 uV, v_off_fin = -83.981 uV 18:14:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.828 uVs 18:14:18 Integrated Voltage Measurement... 18:14:27 Voltage Offset Correction: v_off_ini = -80.781 uV, v_off_fin = -71.093 uV 18:14:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 305.868 uVs 18:14:27 Integrated Voltage Measurement... 18:14:36 Voltage Offset Correction: v_off_ini = -78.981 uV, v_off_fin = -97.609 uV 18:14:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -276.003 uVs 18:14:36 Integrated Voltage Measurement... 18:14:45 Voltage Offset Correction: v_off_ini = -85.949 uV, v_off_fin = -74.441 uV 18:14:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 283.855 uVs 18:14:50 I1Y Average and RMS of Measurements VT = -287.803 +- 5.721 uVs I1Y = -57.557 +- 1.146 uTm 18:14:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:14:55 Integrated Voltage Measurement... 18:15:04 Voltage Offset Correction: v_off_ini = -75.273 uV, v_off_fin = -76.713 uV 18:15:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.193 uVs 18:15:04 Integrated Voltage Measurement... 18:15:13 Voltage Offset Correction: v_off_ini = -71.612 uV, v_off_fin = -69.226 uV 18:15:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.611 uVs 18:15:13 Integrated Voltage Measurement... 18:15:22 Voltage Offset Correction: v_off_ini = -80.769 uV, v_off_fin = -85.934 uV 18:15:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -40.409 uVs 18:15:22 Integrated Voltage Measurement... 18:15:31 Voltage Offset Correction: v_off_ini = -72.539 uV, v_off_fin = -75.893 uV 18:15:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.964 uVs 18:15:31 Integrated Voltage Measurement... 18:15:40 Voltage Offset Correction: v_off_ini = -94.443 uV, v_off_fin = -95.364 uV 18:15:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.565 uVs 18:15:40 Integrated Voltage Measurement... 18:15:49 Voltage Offset Correction: v_off_ini = -80.499 uV, v_off_fin = -74.184 uV 18:15:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.586 uVs 18:15:51 I2X Average and RMS of Measurements VT = -37.388 +- 8.281 uVs I2X = 3.440 +- 0.762 uTm^2 18:15:54 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:15:56 Integrated Voltage Measurement... 18:16:05 Voltage Offset Correction: v_off_ini = -81.405 uV, v_off_fin = -90.147 uV 18:16:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.322 uVs 18:16:05 Integrated Voltage Measurement... 18:16:14 Voltage Offset Correction: v_off_ini = -69.162 uV, v_off_fin = -81.818 uV 18:16:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.418 uVs 18:16:14 Integrated Voltage Measurement... 18:16:23 Voltage Offset Correction: v_off_ini = -85.260 uV, v_off_fin = -87.355 uV 18:16:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.673 uVs 18:16:23 Integrated Voltage Measurement... 18:16:32 Voltage Offset Correction: v_off_ini = -75.463 uV, v_off_fin = -85.263 uV 18:16:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.762 uVs 18:16:32 Integrated Voltage Measurement... 18:16:41 Voltage Offset Correction: v_off_ini = -97.582 uV, v_off_fin = -94.081 uV 18:16:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.489 uVs 18:16:41 Integrated Voltage Measurement... 18:16:50 Voltage Offset Correction: v_off_ini = -100.936 uV, v_off_fin = -96.858 uV 18:16:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.139 uVs 18:16:53 I2Y Average and RMS of Measurements VT = -263.801 +- 5.162 uVs I2Y = -24.270 +- 0.475 uTm^2 18:17:10 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:17:14 Integrated Voltage Measurement... 18:17:23 Voltage Offset Correction: v_off_ini = -83.580 uV, v_off_fin = -90.836 uV 18:17:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -39.797 uVs 18:17:23 Integrated Voltage Measurement... 18:17:32 Voltage Offset Correction: v_off_ini = -82.697 uV, v_off_fin = -92.116 uV 18:17:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.036 uVs 18:17:32 Integrated Voltage Measurement... 18:17:41 Voltage Offset Correction: v_off_ini = -83.835 uV, v_off_fin = -90.376 uV 18:17:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.782 uVs 18:17:41 Integrated Voltage Measurement... 18:17:50 Voltage Offset Correction: v_off_ini = -68.001 uV, v_off_fin = -58.150 uV 18:17:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.887 uVs 18:17:50 Integrated Voltage Measurement... 18:17:59 Voltage Offset Correction: v_off_ini = -69.910 uV, v_off_fin = -91.325 uV 18:17:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.013 uVs 18:17:59 Integrated Voltage Measurement... 18:18:08 Voltage Offset Correction: v_off_ini = -77.722 uV, v_off_fin = -69.341 uV 18:18:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.753 uVs 18:18:12 I1X Average and RMS of Measurements VT = -35.378 +- 3.163 uVs I1X = 7.076 +- 0.632 uTm 18:18:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:18:19 Integrated Voltage Measurement... 18:18:28 Voltage Offset Correction: v_off_ini = -82.018 uV, v_off_fin = -82.844 uV 18:18:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.007 uVs 18:18:28 Integrated Voltage Measurement... 18:18:37 Voltage Offset Correction: v_off_ini = -65.392 uV, v_off_fin = -54.686 uV 18:18:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.972 uVs 18:18:37 Integrated Voltage Measurement... 18:18:46 Voltage Offset Correction: v_off_ini = -89.524 uV, v_off_fin = -88.634 uV 18:18:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -303.200 uVs 18:18:46 Integrated Voltage Measurement... 18:18:55 Voltage Offset Correction: v_off_ini = -78.156 uV, v_off_fin = -63.839 uV 18:18:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.082 uVs 18:18:55 Integrated Voltage Measurement... 18:19:04 Voltage Offset Correction: v_off_ini = -78.855 uV, v_off_fin = -95.414 uV 18:19:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -301.692 uVs 18:19:04 Integrated Voltage Measurement... 18:19:13 Voltage Offset Correction: v_off_ini = -76.959 uV, v_off_fin = -61.333 uV 18:19:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 303.710 uVs 18:19:17 I1Y Average and RMS of Measurements VT = -295.944 +- 6.600 uVs I1Y = -59.189 +- 1.320 uTm 18:19:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:19:24 Integrated Voltage Measurement... 18:19:33 Voltage Offset Correction: v_off_ini = -72.463 uV, v_off_fin = -71.507 uV 18:19:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.602 uVs 18:19:33 Integrated Voltage Measurement... 18:19:42 Voltage Offset Correction: v_off_ini = -74.127 uV, v_off_fin = -59.713 uV 18:19:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 20.733 uVs 18:19:42 Integrated Voltage Measurement... 18:19:51 Voltage Offset Correction: v_off_ini = -67.485 uV, v_off_fin = -80.341 uV 18:19:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.869 uVs 18:19:51 Integrated Voltage Measurement... 18:20:00 Voltage Offset Correction: v_off_ini = -69.578 uV, v_off_fin = -68.186 uV 18:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.436 uVs 18:20:00 Integrated Voltage Measurement... 18:20:09 Voltage Offset Correction: v_off_ini = -71.221 uV, v_off_fin = -94.384 uV 18:20:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 17.947 uVs 18:20:09 Integrated Voltage Measurement... 18:20:18 Voltage Offset Correction: v_off_ini = -84.734 uV, v_off_fin = -74.337 uV 18:20:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.291 uVs 18:20:21 I2X Average and RMS of Measurements VT = -14.164 +- 10.606 uVs I2X = 1.303 +- 0.976 uTm^2 18:20:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 18:20:28 Integrated Voltage Measurement... 18:20:37 Voltage Offset Correction: v_off_ini = -88.965 uV, v_off_fin = -90.927 uV 18:20:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.197 uVs 18:20:37 Integrated Voltage Measurement... 18:20:46 Voltage Offset Correction: v_off_ini = -86.410 uV, v_off_fin = -77.609 uV 18:20:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.000 uVs 18:20:47 Integrated Voltage Measurement... 18:20:55 Voltage Offset Correction: v_off_ini = -73.211 uV, v_off_fin = -67.081 uV 18:20:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.128 uVs 18:20:56 Integrated Voltage Measurement... 18:21:04 Voltage Offset Correction: v_off_ini = -80.349 uV, v_off_fin = -73.524 uV 18:21:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 282.416 uVs 18:21:05 Integrated Voltage Measurement... 18:21:13 Voltage Offset Correction: v_off_ini = -75.874 uV, v_off_fin = -77.832 uV 18:21:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.317 uVs 18:21:14 Integrated Voltage Measurement... 18:21:23 Voltage Offset Correction: v_off_ini = -83.693 uV, v_off_fin = -69.412 uV 18:21:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.034 uVs 18:21:25 I2Y Average and RMS of Measurements VT = -270.515 +- 3.774 uVs I2Y = -24.887 +- 0.347 uTm^2 18:21:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:21:34 Integrated Voltage Measurement... 18:21:43 Voltage Offset Correction: v_off_ini = -78.515 uV, v_off_fin = -88.416 uV 18:21:43 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -53.126 uVs 18:21:43 Integrated Voltage Measurement... 18:21:52 Voltage Offset Correction: v_off_ini = -89.766 uV, v_off_fin = -74.604 uV 18:21:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 56.211 uVs 18:21:52 Integrated Voltage Measurement... 18:22:01 Voltage Offset Correction: v_off_ini = -61.056 uV, v_off_fin = -87.543 uV 18:22:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.854 uVs 18:22:01 Integrated Voltage Measurement... 18:22:10 Voltage Offset Correction: v_off_ini = -92.931 uV, v_off_fin = -77.650 uV 18:22:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.623 uVs 18:22:10 Integrated Voltage Measurement... 18:22:19 Voltage Offset Correction: v_off_ini = -81.462 uV, v_off_fin = -73.188 uV 18:22:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.087 uVs 18:22:19 Integrated Voltage Measurement... 18:22:28 Voltage Offset Correction: v_off_ini = -69.662 uV, v_off_fin = -88.366 uV 18:22:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.857 uVs 18:22:32 I1X Average and RMS of Measurements VT = -56.626 +- 4.803 uVs I1X = 11.326 +- 0.960 uTm 18:22:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:22:39 Integrated Voltage Measurement... 18:22:48 Voltage Offset Correction: v_off_ini = -79.811 uV, v_off_fin = -89.493 uV 18:22:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.656 uVs 18:22:48 Integrated Voltage Measurement... 18:22:57 Voltage Offset Correction: v_off_ini = -65.069 uV, v_off_fin = -71.202 uV 18:22:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 296.377 uVs 18:22:57 Integrated Voltage Measurement... 18:23:05 Voltage Offset Correction: v_off_ini = -71.894 uV, v_off_fin = -79.755 uV 18:23:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -303.550 uVs 18:23:06 Integrated Voltage Measurement... 18:23:14 Voltage Offset Correction: v_off_ini = -71.320 uV, v_off_fin = -58.046 uV 18:23:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.662 uVs 18:23:15 Integrated Voltage Measurement... 18:23:23 Voltage Offset Correction: v_off_ini = -53.571 uV, v_off_fin = -57.644 uV 18:23:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -314.500 uVs 18:23:24 Integrated Voltage Measurement... 18:23:32 Voltage Offset Correction: v_off_ini = -74.721 uV, v_off_fin = -49.431 uV 18:23:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 302.976 uVs 18:23:37 I1Y Average and RMS of Measurements VT = -295.953 +- 9.074 uVs I1Y = -59.191 +- 1.815 uTm 18:23:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:23:44 Integrated Voltage Measurement... 18:23:53 Voltage Offset Correction: v_off_ini = -75.521 uV, v_off_fin = -56.995 uV 18:23:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -9.083 uVs 18:23:53 Integrated Voltage Measurement... 18:24:02 Voltage Offset Correction: v_off_ini = -85.139 uV, v_off_fin = -78.405 uV 18:24:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.247 uVs 18:24:02 Integrated Voltage Measurement... 18:24:11 Voltage Offset Correction: v_off_ini = -69.936 uV, v_off_fin = -76.854 uV 18:24:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.725 uVs 18:24:11 Integrated Voltage Measurement... 18:24:20 Voltage Offset Correction: v_off_ini = -64.407 uV, v_off_fin = -63.120 uV 18:24:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 31.830 uVs 18:24:20 Integrated Voltage Measurement... 18:24:29 Voltage Offset Correction: v_off_ini = -80.504 uV, v_off_fin = -77.091 uV 18:24:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -8.502 uVs 18:24:29 Integrated Voltage Measurement... 18:24:38 Voltage Offset Correction: v_off_ini = -70.022 uV, v_off_fin = -55.485 uV 18:24:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.636 uVs 18:24:41 I2X Average and RMS of Measurements VT = -23.671 +- 5.672 uVs I2X = 2.178 +- 0.522 uTm^2 18:24:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 18:24:49 Integrated Voltage Measurement... 18:24:57 Voltage Offset Correction: v_off_ini = -67.694 uV, v_off_fin = -67.989 uV 18:24:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.097 uVs 18:24:58 Integrated Voltage Measurement... 18:25:07 Voltage Offset Correction: v_off_ini = -66.551 uV, v_off_fin = -80.419 uV 18:25:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.743 uVs 18:25:07 Integrated Voltage Measurement... 18:25:16 Voltage Offset Correction: v_off_ini = -76.756 uV, v_off_fin = -71.504 uV 18:25:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.704 uVs 18:25:16 Integrated Voltage Measurement... 18:25:25 Voltage Offset Correction: v_off_ini = -68.645 uV, v_off_fin = -65.541 uV 18:25:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.067 uVs 18:25:25 Integrated Voltage Measurement... 18:25:34 Voltage Offset Correction: v_off_ini = -73.449 uV, v_off_fin = -81.947 uV 18:25:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.632 uVs 18:25:34 Integrated Voltage Measurement... 18:25:43 Voltage Offset Correction: v_off_ini = -65.772 uV, v_off_fin = -74.934 uV 18:25:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.514 uVs 18:25:45 I2Y Average and RMS of Measurements VT = -268.460 +- 10.428 uVs I2Y = -24.698 +- 0.959 uTm^2 18:25:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:25:54 Integrated Voltage Measurement... 18:26:03 Voltage Offset Correction: v_off_ini = -44.702 uV, v_off_fin = -65.422 uV 18:26:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -55.321 uVs 18:26:03 Integrated Voltage Measurement... 18:26:12 Voltage Offset Correction: v_off_ini = -56.381 uV, v_off_fin = -61.437 uV 18:26:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.615 uVs 18:26:12 Integrated Voltage Measurement... 18:26:21 Voltage Offset Correction: v_off_ini = -62.379 uV, v_off_fin = -71.307 uV 18:26:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.690 uVs 18:26:21 Integrated Voltage Measurement... 18:26:30 Voltage Offset Correction: v_off_ini = -57.695 uV, v_off_fin = -49.788 uV 18:26:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.460 uVs 18:26:30 Integrated Voltage Measurement... 18:26:39 Voltage Offset Correction: v_off_ini = -57.752 uV, v_off_fin = -59.891 uV 18:26:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.360 uVs 18:26:39 Integrated Voltage Measurement... 18:26:48 Voltage Offset Correction: v_off_ini = -57.481 uV, v_off_fin = -51.773 uV 18:26:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.508 uVs 18:26:52 I1X Average and RMS of Measurements VT = -51.826 +- 5.910 uVs I1X = 10.365 +- 1.182 uTm 18:26:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:26:59 Integrated Voltage Measurement... 18:27:08 Voltage Offset Correction: v_off_ini = -57.263 uV, v_off_fin = -71.052 uV 18:27:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.985 uVs 18:27:08 Integrated Voltage Measurement... 18:27:17 Voltage Offset Correction: v_off_ini = -51.867 uV, v_off_fin = -31.673 uV 18:27:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 294.295 uVs 18:27:17 Integrated Voltage Measurement... 18:27:26 Voltage Offset Correction: v_off_ini = -41.774 uV, v_off_fin = -48.345 uV 18:27:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.817 uVs 18:27:26 Integrated Voltage Measurement... 18:27:35 Voltage Offset Correction: v_off_ini = -54.156 uV, v_off_fin = -59.223 uV 18:27:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.188 uVs 18:27:35 Integrated Voltage Measurement... 18:27:44 Voltage Offset Correction: v_off_ini = -63.728 uV, v_off_fin = -69.249 uV 18:27:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -293.596 uVs 18:27:44 Integrated Voltage Measurement... 18:27:53 Voltage Offset Correction: v_off_ini = -51.195 uV, v_off_fin = -32.082 uV 18:27:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 296.787 uVs 18:27:57 I1Y Average and RMS of Measurements VT = -286.278 +- 8.410 uVs I1Y = -57.257 +- 1.683 uTm 18:28:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:28:05 Integrated Voltage Measurement... 18:28:14 Voltage Offset Correction: v_off_ini = -43.895 uV, v_off_fin = -44.593 uV 18:28:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.096 uVs 18:28:14 Integrated Voltage Measurement... 18:28:23 Voltage Offset Correction: v_off_ini = -42.878 uV, v_off_fin = -36.190 uV 18:28:23 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 35.651 uVs 18:28:23 Integrated Voltage Measurement... 18:28:32 Voltage Offset Correction: v_off_ini = -42.062 uV, v_off_fin = -50.806 uV 18:28:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.330 uVs 18:28:32 Integrated Voltage Measurement... 18:28:41 Voltage Offset Correction: v_off_ini = -46.257 uV, v_off_fin = -42.481 uV 18:28:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.779 uVs 18:28:41 Integrated Voltage Measurement... 18:28:50 Voltage Offset Correction: v_off_ini = -42.481 uV, v_off_fin = -67.677 uV 18:28:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.143 uVs 18:28:50 Integrated Voltage Measurement... 18:28:59 Voltage Offset Correction: v_off_ini = -50.800 uV, v_off_fin = -40.043 uV 18:28:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.802 uVs 18:29:01 I2X Average and RMS of Measurements VT = -44.967 +- 6.192 uVs I2X = 4.137 +- 0.570 uTm^2 18:29:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:29:09 Integrated Voltage Measurement... 18:29:18 Voltage Offset Correction: v_off_ini = -28.641 uV, v_off_fin = -46.060 uV 18:29:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.493 uVs 18:29:18 Integrated Voltage Measurement... 18:29:27 Voltage Offset Correction: v_off_ini = -51.754 uV, v_off_fin = -42.298 uV 18:29:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.847 uVs 18:29:27 Integrated Voltage Measurement... 18:29:36 Voltage Offset Correction: v_off_ini = -26.476 uV, v_off_fin = -25.689 uV 18:29:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.670 uVs 18:29:36 Integrated Voltage Measurement... 18:29:45 Voltage Offset Correction: v_off_ini = -18.745 uV, v_off_fin = -29.711 uV 18:29:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.964 uVs 18:29:45 Integrated Voltage Measurement... 18:29:54 Voltage Offset Correction: v_off_ini = -32.424 uV, v_off_fin = -40.071 uV 18:29:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.743 uVs 18:29:54 Integrated Voltage Measurement... 18:30:03 Voltage Offset Correction: v_off_ini = -36.017 uV, v_off_fin = -24.022 uV 18:30:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.903 uVs 18:30:06 I2Y Average and RMS of Measurements VT = -263.437 +- 7.514 uVs I2Y = -24.236 +- 0.691 uTm^2 18:30:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:30:15 Integrated Voltage Measurement... 18:30:24 Voltage Offset Correction: v_off_ini = -36.872 uV, v_off_fin = -31.068 uV 18:30:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -63.946 uVs 18:30:24 Integrated Voltage Measurement... 18:30:33 Voltage Offset Correction: v_off_ini = -20.553 uV, v_off_fin = -11.064 uV 18:30:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.048 uVs 18:30:33 Integrated Voltage Measurement... 18:30:42 Voltage Offset Correction: v_off_ini = -38.403 uV, v_off_fin = -42.380 uV 18:30:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -52.115 uVs 18:30:42 Integrated Voltage Measurement... 18:30:51 Voltage Offset Correction: v_off_ini = -31.360 uV, v_off_fin = -36.358 uV 18:30:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.922 uVs 18:30:51 Integrated Voltage Measurement... 18:31:00 Voltage Offset Correction: v_off_ini = -33.675 uV, v_off_fin = -35.881 uV 18:31:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.051 uVs 18:31:00 Integrated Voltage Measurement... 18:31:09 Voltage Offset Correction: v_off_ini = -35.088 uV, v_off_fin = -31.015 uV 18:31:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.939 uVs 18:31:13 I1X Average and RMS of Measurements VT = -67.503 +- 4.481 uVs I1X = 13.501 +- 0.896 uTm 18:31:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:31:20 Integrated Voltage Measurement... 18:31:29 Voltage Offset Correction: v_off_ini = -46.950 uV, v_off_fin = -37.711 uV 18:31:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -282.635 uVs 18:31:29 Integrated Voltage Measurement... 18:31:38 Voltage Offset Correction: v_off_ini = -42.339 uV, v_off_fin = -35.710 uV 18:31:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.434 uVs 18:31:38 Integrated Voltage Measurement... 18:31:47 Voltage Offset Correction: v_off_ini = -27.589 uV, v_off_fin = -47.358 uV 18:31:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.390 uVs 18:31:47 Integrated Voltage Measurement... 18:31:56 Voltage Offset Correction: v_off_ini = -36.947 uV, v_off_fin = -34.445 uV 18:31:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.650 uVs 18:31:56 Integrated Voltage Measurement... 18:32:05 Voltage Offset Correction: v_off_ini = -41.089 uV, v_off_fin = -45.052 uV 18:32:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -290.660 uVs 18:32:05 Integrated Voltage Measurement... 18:32:14 Voltage Offset Correction: v_off_ini = -43.909 uV, v_off_fin = -29.551 uV 18:32:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.157 uVs 18:32:18 I1Y Average and RMS of Measurements VT = -281.821 +- 1.424 uVs I1Y = -56.365 +- 0.284 uTm 18:32:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:32:26 Integrated Voltage Measurement... 18:32:35 Voltage Offset Correction: v_off_ini = -39.649 uV, v_off_fin = -45.901 uV 18:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.845 uVs 18:32:35 Integrated Voltage Measurement... 18:32:44 Voltage Offset Correction: v_off_ini = -42.267 uV, v_off_fin = -29.109 uV 18:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.525 uVs 18:32:44 Integrated Voltage Measurement... 18:32:53 Voltage Offset Correction: v_off_ini = -23.927 uV, v_off_fin = -36.059 uV 18:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.510 uVs 18:32:53 Integrated Voltage Measurement... 18:33:02 Voltage Offset Correction: v_off_ini = -25.026 uV, v_off_fin = -21.281 uV 18:33:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 55.059 uVs 18:33:02 Integrated Voltage Measurement... 18:33:11 Voltage Offset Correction: v_off_ini = -32.863 uV, v_off_fin = -44.620 uV 18:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.321 uVs 18:33:11 Integrated Voltage Measurement... 18:33:20 Voltage Offset Correction: v_off_ini = -42.903 uV, v_off_fin = -40.354 uV 18:33:20 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 44.082 uVs 18:33:22 I2X Average and RMS of Measurements VT = -46.890 +- 4.889 uVs I2X = 4.314 +- 0.450 uTm^2 18:33:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 18:33:30 Integrated Voltage Measurement... 18:33:39 Voltage Offset Correction: v_off_ini = -32.733 uV, v_off_fin = -44.357 uV 18:33:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.535 uVs 18:33:39 Integrated Voltage Measurement... 18:33:48 Voltage Offset Correction: v_off_ini = -49.869 uV, v_off_fin = -46.743 uV 18:33:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.198 uVs 18:33:48 Integrated Voltage Measurement... 18:33:57 Voltage Offset Correction: v_off_ini = -44.750 uV, v_off_fin = -44.005 uV 18:33:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.828 uVs 18:33:57 Integrated Voltage Measurement... 18:34:06 Voltage Offset Correction: v_off_ini = -52.624 uV, v_off_fin = -45.676 uV 18:34:06 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 267.682 uVs 18:34:06 Integrated Voltage Measurement... 18:34:15 Voltage Offset Correction: v_off_ini = -42.880 uV, v_off_fin = -41.367 uV 18:34:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.687 uVs 18:34:15 Integrated Voltage Measurement... 18:34:24 Voltage Offset Correction: v_off_ini = -44.882 uV, v_off_fin = -29.337 uV 18:34:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.828 uVs 18:34:27 I2Y Average and RMS of Measurements VT = -257.960 +- 6.849 uVs I2Y = -23.733 +- 0.630 uTm^2 18:34:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:34:35 Integrated Voltage Measurement... 18:34:44 Voltage Offset Correction: v_off_ini = -21.820 uV, v_off_fin = -33.246 uV 18:34:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.851 uVs 18:34:44 Integrated Voltage Measurement... 18:34:53 Voltage Offset Correction: v_off_ini = -36.076 uV, v_off_fin = -20.237 uV 18:34:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.445 uVs 18:34:53 Integrated Voltage Measurement... 18:35:02 Voltage Offset Correction: v_off_ini = -11.918 uV, v_off_fin = -27.999 uV 18:35:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -76.099 uVs 18:35:02 Integrated Voltage Measurement... 18:35:11 Voltage Offset Correction: v_off_ini = -20.875 uV, v_off_fin = -23.497 uV 18:35:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.308 uVs 18:35:11 Integrated Voltage Measurement... 18:35:20 Voltage Offset Correction: v_off_ini = -4.789 uV, v_off_fin = -33.967 uV 18:35:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.862 uVs 18:35:21 Integrated Voltage Measurement... 18:35:29 Voltage Offset Correction: v_off_ini = -18.372 uV, v_off_fin = -22.407 uV 18:35:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.023 uVs 18:35:34 I1X Average and RMS of Measurements VT = -71.431 +- 6.593 uVs I1X = 14.287 +- 1.319 uTm 18:35:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:35:41 Integrated Voltage Measurement... 18:35:49 Voltage Offset Correction: v_off_ini = -19.177 uV, v_off_fin = -38.385 uV 18:35:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -283.405 uVs 18:35:50 Integrated Voltage Measurement... 18:35:58 Voltage Offset Correction: v_off_ini = -37.236 uV, v_off_fin = -22.216 uV 18:35:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.465 uVs 18:35:59 Integrated Voltage Measurement... 18:36:07 Voltage Offset Correction: v_off_ini = -16.549 uV, v_off_fin = -20.293 uV 18:36:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.313 uVs 18:36:08 Integrated Voltage Measurement... 18:36:16 Voltage Offset Correction: v_off_ini = -13.912 uV, v_off_fin = -1.035 uV 18:36:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.899 uVs 18:36:17 Integrated Voltage Measurement... 18:36:25 Voltage Offset Correction: v_off_ini = -22.766 uV, v_off_fin = -40.371 uV 18:36:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.281 uVs 18:36:26 Integrated Voltage Measurement... 18:36:34 Voltage Offset Correction: v_off_ini = -27.973 uV, v_off_fin = -4.892 uV 18:36:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.943 uVs 18:36:39 I1Y Average and RMS of Measurements VT = -278.551 +- 8.222 uVs I1Y = -55.711 +- 1.645 uTm 18:36:44 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:36:46 Integrated Voltage Measurement... 18:36:55 Voltage Offset Correction: v_off_ini = -14.034 uV, v_off_fin = -25.250 uV 18:36:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.222 uVs 18:36:56 Integrated Voltage Measurement... 18:37:04 Voltage Offset Correction: v_off_ini = -22.802 uV, v_off_fin = -15.699 uV 18:37:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.919 uVs 18:37:05 Integrated Voltage Measurement... 18:37:14 Voltage Offset Correction: v_off_ini = -11.460 uV, v_off_fin = -17.218 uV 18:37:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.221 uVs 18:37:14 Integrated Voltage Measurement... 18:37:23 Voltage Offset Correction: v_off_ini = -8.429 uV, v_off_fin = -6.374 uV 18:37:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.402 uVs 18:37:23 Integrated Voltage Measurement... 18:37:32 Voltage Offset Correction: v_off_ini = -2.596 uV, v_off_fin = -13.897 uV 18:37:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.716 uVs 18:37:32 Integrated Voltage Measurement... 18:37:41 Voltage Offset Correction: v_off_ini = -28.149 uV, v_off_fin = -14.615 uV 18:37:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.705 uVs 18:37:43 I2X Average and RMS of Measurements VT = -57.031 +- 6.006 uVs I2X = 5.247 +- 0.553 uTm^2 18:37:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 18:37:51 Integrated Voltage Measurement... 18:38:00 Voltage Offset Correction: v_off_ini = -19.407 uV, v_off_fin = -26.934 uV 18:38:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.522 uVs 18:38:00 Integrated Voltage Measurement... 18:38:09 Voltage Offset Correction: v_off_ini = -39.097 uV, v_off_fin = -13.411 uV 18:38:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.477 uVs 18:38:09 Integrated Voltage Measurement... 18:38:18 Voltage Offset Correction: v_off_ini = -30.635 uV, v_off_fin = -20.392 uV 18:38:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.069 uVs 18:38:18 Integrated Voltage Measurement... 18:38:27 Voltage Offset Correction: v_off_ini = -4.858 uV, v_off_fin = -17.359 uV 18:38:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.599 uVs 18:38:27 Integrated Voltage Measurement... 18:38:36 Voltage Offset Correction: v_off_ini = -10.960 uV, v_off_fin = -8.038 uV 18:38:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.748 uVs 18:38:36 Integrated Voltage Measurement... 18:38:45 Voltage Offset Correction: v_off_ini = -2.832 uV, v_off_fin = -2.766 uV 18:38:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.795 uVs 18:38:47 I2Y Average and RMS of Measurements VT = -249.702 +- 4.822 uVs I2Y = -22.973 +- 0.444 uTm^2 18:38:55 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:38:59 Integrated Voltage Measurement... 18:39:08 Voltage Offset Correction: v_off_ini = 18.727 uV, v_off_fin = 7.074 uV 18:39:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.474 uVs 18:39:08 Integrated Voltage Measurement... 18:39:17 Voltage Offset Correction: v_off_ini = 15.818 uV, v_off_fin = 8.035 uV 18:39:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.432 uVs 18:39:17 Integrated Voltage Measurement... 18:39:26 Voltage Offset Correction: v_off_ini = 2.203 uV, v_off_fin = -4.219 uV 18:39:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -53.049 uVs 18:39:26 Integrated Voltage Measurement... 18:39:35 Voltage Offset Correction: v_off_ini = 11.709 uV, v_off_fin = -2.679 uV 18:39:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 68.507 uVs 18:39:36 Integrated Voltage Measurement... 18:39:44 Voltage Offset Correction: v_off_ini = -9.480 uV, v_off_fin = -16.939 uV 18:39:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.535 uVs 18:39:45 Integrated Voltage Measurement... 18:39:53 Voltage Offset Correction: v_off_ini = -20.687 uV, v_off_fin = -14.003 uV 18:39:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.726 uVs 18:39:58 I1X Average and RMS of Measurements VT = -47.287 +- 9.545 uVs I1X = 9.458 +- 1.910 uTm 18:40:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:40:05 Integrated Voltage Measurement... 18:40:13 Voltage Offset Correction: v_off_ini = -11.667 uV, v_off_fin = -22.351 uV 18:40:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -286.091 uVs 18:40:14 Integrated Voltage Measurement... 18:40:22 Voltage Offset Correction: v_off_ini = -19.480 uV, v_off_fin = -1.126 uV 18:40:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.871 uVs 18:40:23 Integrated Voltage Measurement... 18:40:31 Voltage Offset Correction: v_off_ini = -14.878 uV, v_off_fin = -35.094 uV 18:40:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.712 uVs 18:40:32 Integrated Voltage Measurement... 18:40:40 Voltage Offset Correction: v_off_ini = -20.224 uV, v_off_fin = -17.149 uV 18:40:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.056 uVs 18:40:41 Integrated Voltage Measurement... 18:40:50 Voltage Offset Correction: v_off_ini = -24.426 uV, v_off_fin = -40.885 uV 18:40:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -274.619 uVs 18:40:50 Integrated Voltage Measurement... 18:40:59 Voltage Offset Correction: v_off_ini = -24.501 uV, v_off_fin = -6.641 uV 18:40:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 270.357 uVs 18:41:03 I1Y Average and RMS of Measurements VT = -279.951 +- 5.283 uVs I1Y = -55.990 +- 1.057 uTm 18:41:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:41:08 Integrated Voltage Measurement... 18:41:17 Voltage Offset Correction: v_off_ini = -39.276 uV, v_off_fin = -45.305 uV 18:41:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.144 uVs 18:41:17 Integrated Voltage Measurement... 18:41:26 Voltage Offset Correction: v_off_ini = -32.831 uV, v_off_fin = -39.731 uV 18:41:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.506 uVs 18:41:26 Integrated Voltage Measurement... 18:41:35 Voltage Offset Correction: v_off_ini = -33.878 uV, v_off_fin = -45.805 uV 18:41:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -26.006 uVs 18:41:35 Integrated Voltage Measurement... 18:41:44 Voltage Offset Correction: v_off_ini = -36.608 uV, v_off_fin = -24.536 uV 18:41:44 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 29.623 uVs 18:41:44 Integrated Voltage Measurement... 18:41:53 Voltage Offset Correction: v_off_ini = -28.688 uV, v_off_fin = -48.730 uV 18:41:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.961 uVs 18:41:53 Integrated Voltage Measurement... 18:42:02 Voltage Offset Correction: v_off_ini = -32.713 uV, v_off_fin = -28.681 uV 18:42:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 19.230 uVs 18:42:04 I2X Average and RMS of Measurements VT = -18.910 +- 8.308 uVs I2X = 1.740 +- 0.764 uTm^2 18:42:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 18:42:10 Integrated Voltage Measurement... 18:42:19 Voltage Offset Correction: v_off_ini = -48.434 uV, v_off_fin = -44.963 uV 18:42:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.392 uVs 18:42:19 Integrated Voltage Measurement... 18:42:28 Voltage Offset Correction: v_off_ini = -48.842 uV, v_off_fin = -35.096 uV 18:42:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.697 uVs 18:42:28 Integrated Voltage Measurement... 18:42:37 Voltage Offset Correction: v_off_ini = -42.862 uV, v_off_fin = -34.587 uV 18:42:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.585 uVs 18:42:37 Integrated Voltage Measurement... 18:42:46 Voltage Offset Correction: v_off_ini = -38.859 uV, v_off_fin = -42.636 uV 18:42:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.255 uVs 18:42:46 Integrated Voltage Measurement... 18:42:55 Voltage Offset Correction: v_off_ini = -36.516 uV, v_off_fin = -42.363 uV 18:42:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.580 uVs 18:42:55 Integrated Voltage Measurement... 18:43:04 Voltage Offset Correction: v_off_ini = -45.170 uV, v_off_fin = -47.928 uV 18:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.724 uVs 18:43:06 I2Y Average and RMS of Measurements VT = -249.039 +- 6.840 uVs I2Y = -22.912 +- 0.629 uTm^2 18:43:10 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:43:15 Integrated Voltage Measurement... 18:43:24 Voltage Offset Correction: v_off_ini = -41.360 uV, v_off_fin = -41.209 uV 18:43:24 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -54.000 uVs 18:43:24 Integrated Voltage Measurement... 18:43:33 Voltage Offset Correction: v_off_ini = -47.088 uV, v_off_fin = -56.144 uV 18:43:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 43.342 uVs 18:43:33 Integrated Voltage Measurement... 18:43:42 Voltage Offset Correction: v_off_ini = -47.509 uV, v_off_fin = -62.254 uV 18:43:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.254 uVs 18:43:42 Integrated Voltage Measurement... 18:43:51 Voltage Offset Correction: v_off_ini = -55.478 uV, v_off_fin = -46.974 uV 18:43:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.499 uVs 18:43:51 Integrated Voltage Measurement... 18:44:00 Voltage Offset Correction: v_off_ini = -55.478 uV, v_off_fin = -60.724 uV 18:44:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.700 uVs 18:44:00 Integrated Voltage Measurement... 18:44:09 Voltage Offset Correction: v_off_ini = -49.817 uV, v_off_fin = -51.510 uV 18:44:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.564 uVs 18:44:13 I1X Average and RMS of Measurements VT = -48.227 +- 1.561 uVs I1X = 9.646 +- 0.312 uTm 18:44:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:44:20 Integrated Voltage Measurement... 18:44:29 Voltage Offset Correction: v_off_ini = -74.211 uV, v_off_fin = -90.214 uV 18:44:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.821 uVs 18:44:29 Integrated Voltage Measurement... 18:44:38 Voltage Offset Correction: v_off_ini = -71.585 uV, v_off_fin = -71.351 uV 18:44:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 280.274 uVs 18:44:38 Integrated Voltage Measurement... 18:44:47 Voltage Offset Correction: v_off_ini = -76.370 uV, v_off_fin = -84.026 uV 18:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.047 uVs 18:44:47 Integrated Voltage Measurement... 18:44:56 Voltage Offset Correction: v_off_ini = -66.249 uV, v_off_fin = -74.352 uV 18:44:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 280.315 uVs 18:44:56 Integrated Voltage Measurement... 18:45:05 Voltage Offset Correction: v_off_ini = -87.911 uV, v_off_fin = -113.193 uV 18:45:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.774 uVs 18:45:05 Integrated Voltage Measurement... 18:45:14 Voltage Offset Correction: v_off_ini = -84.125 uV, v_off_fin = -74.731 uV 18:45:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.103 uVs 18:45:18 I1Y Average and RMS of Measurements VT = -280.056 +- 5.881 uVs I1Y = -56.011 +- 1.176 uTm 18:45:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:45:23 Integrated Voltage Measurement... 18:45:32 Voltage Offset Correction: v_off_ini = -84.390 uV, v_off_fin = -77.150 uV 18:45:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.870 uVs 18:45:32 Integrated Voltage Measurement... 18:45:41 Voltage Offset Correction: v_off_ini = -74.467 uV, v_off_fin = -63.316 uV 18:45:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.942 uVs 18:45:41 Integrated Voltage Measurement... 18:45:50 Voltage Offset Correction: v_off_ini = -90.775 uV, v_off_fin = -101.771 uV 18:45:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.654 uVs 18:45:50 Integrated Voltage Measurement... 18:45:59 Voltage Offset Correction: v_off_ini = -102.855 uV, v_off_fin = -89.447 uV 18:45:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.968 uVs 18:45:59 Integrated Voltage Measurement... 18:46:08 Voltage Offset Correction: v_off_ini = -93.699 uV, v_off_fin = -108.125 uV 18:46:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.279 uVs 18:46:08 Integrated Voltage Measurement... 18:46:17 Voltage Offset Correction: v_off_ini = -99.702 uV, v_off_fin = -99.506 uV 18:46:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.477 uVs 18:46:20 I2X Average and RMS of Measurements VT = -32.365 +- 4.055 uVs I2X = 2.978 +- 0.373 uTm^2 18:46:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 18:46:25 Integrated Voltage Measurement... 18:46:34 Voltage Offset Correction: v_off_ini = -95.046 uV, v_off_fin = -109.291 uV 18:46:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.577 uVs 18:46:34 Integrated Voltage Measurement... 18:46:43 Voltage Offset Correction: v_off_ini = -111.908 uV, v_off_fin = -102.815 uV 18:46:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.923 uVs 18:46:43 Integrated Voltage Measurement... 18:46:52 Voltage Offset Correction: v_off_ini = -99.328 uV, v_off_fin = -93.307 uV 18:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.737 uVs 18:46:52 Integrated Voltage Measurement... 18:47:01 Voltage Offset Correction: v_off_ini = -115.958 uV, v_off_fin = -110.132 uV 18:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.726 uVs 18:47:01 Integrated Voltage Measurement... 18:47:10 Voltage Offset Correction: v_off_ini = -107.658 uV, v_off_fin = -108.778 uV 18:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.430 uVs 18:47:10 Integrated Voltage Measurement... 18:47:19 Voltage Offset Correction: v_off_ini = -95.842 uV, v_off_fin = -84.688 uV 18:47:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.513 uVs 18:47:21 I2Y Average and RMS of Measurements VT = -258.984 +- 3.478 uVs I2Y = -23.827 +- 0.320 uTm^2 18:47:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:47:30 Integrated Voltage Measurement... 18:47:39 Voltage Offset Correction: v_off_ini = -94.524 uV, v_off_fin = -92.356 uV 18:47:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -49.079 uVs 18:47:39 Integrated Voltage Measurement... 18:47:48 Voltage Offset Correction: v_off_ini = -75.866 uV, v_off_fin = -71.468 uV 18:47:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.786 uVs 18:47:48 Integrated Voltage Measurement... 18:47:57 Voltage Offset Correction: v_off_ini = -70.026 uV, v_off_fin = -84.579 uV 18:47:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.070 uVs 18:47:57 Integrated Voltage Measurement... 18:48:06 Voltage Offset Correction: v_off_ini = -99.037 uV, v_off_fin = -94.435 uV 18:48:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.135 uVs 18:48:06 Integrated Voltage Measurement... 18:48:15 Voltage Offset Correction: v_off_ini = -86.315 uV, v_off_fin = -85.678 uV 18:48:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.163 uVs 18:48:15 Integrated Voltage Measurement... 18:48:24 Voltage Offset Correction: v_off_ini = -84.156 uV, v_off_fin = -80.486 uV 18:48:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.224 uVs 18:48:28 I1X Average and RMS of Measurements VT = -57.743 +- 5.496 uVs I1X = 11.549 +- 1.099 uTm 18:48:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:48:35 Integrated Voltage Measurement... 18:48:44 Voltage Offset Correction: v_off_ini = -76.026 uV, v_off_fin = -88.751 uV 18:48:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.286 uVs 18:48:44 Integrated Voltage Measurement... 18:48:53 Voltage Offset Correction: v_off_ini = -81.085 uV, v_off_fin = -69.075 uV 18:48:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 288.542 uVs 18:48:53 Integrated Voltage Measurement... 18:49:02 Voltage Offset Correction: v_off_ini = -108.545 uV, v_off_fin = -108.259 uV 18:49:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.362 uVs 18:49:02 Integrated Voltage Measurement... 18:49:11 Voltage Offset Correction: v_off_ini = -96.318 uV, v_off_fin = -75.814 uV 18:49:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 285.812 uVs 18:49:11 Integrated Voltage Measurement... 18:49:20 Voltage Offset Correction: v_off_ini = -95.355 uV, v_off_fin = -96.515 uV 18:49:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.860 uVs 18:49:20 Integrated Voltage Measurement... 18:49:29 Voltage Offset Correction: v_off_ini = -93.671 uV, v_off_fin = -75.549 uV 18:49:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 290.149 uVs 18:49:33 I1Y Average and RMS of Measurements VT = -285.668 +- 2.360 uVs I1Y = -57.134 +- 0.472 uTm 18:49:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:49:38 Integrated Voltage Measurement... 18:49:47 Voltage Offset Correction: v_off_ini = -60.389 uV, v_off_fin = -72.852 uV 18:49:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.146 uVs 18:49:47 Integrated Voltage Measurement... 18:49:56 Voltage Offset Correction: v_off_ini = -65.971 uV, v_off_fin = -65.621 uV 18:49:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 34.336 uVs 18:49:56 Integrated Voltage Measurement... 18:50:05 Voltage Offset Correction: v_off_ini = -76.435 uV, v_off_fin = -88.607 uV 18:50:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.988 uVs 18:50:05 Integrated Voltage Measurement... 18:50:14 Voltage Offset Correction: v_off_ini = -90.828 uV, v_off_fin = -82.780 uV 18:50:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.958 uVs 18:50:14 Integrated Voltage Measurement... 18:50:23 Voltage Offset Correction: v_off_ini = -94.034 uV, v_off_fin = -90.276 uV 18:50:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.069 uVs 18:50:23 Integrated Voltage Measurement... 18:50:32 Voltage Offset Correction: v_off_ini = -89.848 uV, v_off_fin = -75.625 uV 18:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.794 uVs 18:50:35 I2X Average and RMS of Measurements VT = -34.382 +- 5.756 uVs I2X = 3.163 +- 0.530 uTm^2 18:50:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 18:50:40 Integrated Voltage Measurement... 18:50:49 Voltage Offset Correction: v_off_ini = -84.908 uV, v_off_fin = -74.013 uV 18:50:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.746 uVs 18:50:49 Integrated Voltage Measurement... 18:50:58 Voltage Offset Correction: v_off_ini = -74.400 uV, v_off_fin = -72.791 uV 18:50:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.267 uVs 18:50:58 Integrated Voltage Measurement... 18:51:07 Voltage Offset Correction: v_off_ini = -75.396 uV, v_off_fin = -84.015 uV 18:51:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.011 uVs 18:51:07 Integrated Voltage Measurement... 18:51:16 Voltage Offset Correction: v_off_ini = -68.168 uV, v_off_fin = -69.523 uV 18:51:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.694 uVs 18:51:16 Integrated Voltage Measurement... 18:51:25 Voltage Offset Correction: v_off_ini = -63.184 uV, v_off_fin = -58.898 uV 18:51:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.084 uVs 18:51:25 Integrated Voltage Measurement... 18:51:34 Voltage Offset Correction: v_off_ini = -62.467 uV, v_off_fin = -63.979 uV 18:51:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.615 uVs 18:51:37 I2Y Average and RMS of Measurements VT = -260.569 +- 0.969 uVs I2Y = -23.972 +- 0.089 uTm^2 18:51:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:51:45 Integrated Voltage Measurement... 18:51:54 Voltage Offset Correction: v_off_ini = -76.256 uV, v_off_fin = -82.363 uV 18:51:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.720 uVs 18:51:54 Integrated Voltage Measurement... 18:52:03 Voltage Offset Correction: v_off_ini = -73.910 uV, v_off_fin = -58.803 uV 18:52:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.457 uVs 18:52:03 Integrated Voltage Measurement... 18:52:12 Voltage Offset Correction: v_off_ini = -61.485 uV, v_off_fin = -73.290 uV 18:52:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.597 uVs 18:52:12 Integrated Voltage Measurement... 18:52:21 Voltage Offset Correction: v_off_ini = -65.437 uV, v_off_fin = -69.891 uV 18:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.825 uVs 18:52:21 Integrated Voltage Measurement... 18:52:30 Voltage Offset Correction: v_off_ini = -77.907 uV, v_off_fin = -73.224 uV 18:52:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.973 uVs 18:52:30 Integrated Voltage Measurement... 18:52:39 Voltage Offset Correction: v_off_ini = -74.941 uV, v_off_fin = -68.981 uV 18:52:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.025 uVs 18:52:43 I1X Average and RMS of Measurements VT = -60.766 +- 2.647 uVs I1X = 12.153 +- 0.529 uTm 18:52:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:52:50 Integrated Voltage Measurement... 18:52:59 Voltage Offset Correction: v_off_ini = -66.135 uV, v_off_fin = -65.422 uV 18:52:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -299.895 uVs 18:52:59 Integrated Voltage Measurement... 18:53:08 Voltage Offset Correction: v_off_ini = -68.774 uV, v_off_fin = -51.096 uV 18:53:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.920 uVs 18:53:08 Integrated Voltage Measurement... 18:53:17 Voltage Offset Correction: v_off_ini = -55.544 uV, v_off_fin = -82.104 uV 18:53:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.195 uVs 18:53:17 Integrated Voltage Measurement... 18:53:26 Voltage Offset Correction: v_off_ini = -73.937 uV, v_off_fin = -51.546 uV 18:53:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 290.828 uVs 18:53:26 Integrated Voltage Measurement... 18:53:35 Voltage Offset Correction: v_off_ini = -54.371 uV, v_off_fin = -88.164 uV 18:53:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.701 uVs 18:53:35 Integrated Voltage Measurement... 18:53:44 Voltage Offset Correction: v_off_ini = -52.086 uV, v_off_fin = -36.424 uV 18:53:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 307.933 uVs 18:53:48 I1Y Average and RMS of Measurements VT = -292.245 +- 3.701 uVs I1Y = -58.450 +- 0.739 uTm 18:53:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:53:53 Integrated Voltage Measurement... 18:54:02 Voltage Offset Correction: v_off_ini = -51.274 uV, v_off_fin = -75.841 uV 18:54:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.849 uVs 18:54:02 Integrated Voltage Measurement... 18:54:11 Voltage Offset Correction: v_off_ini = -77.396 uV, v_off_fin = -65.396 uV 18:54:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.448 uVs 18:54:11 Integrated Voltage Measurement... 18:54:20 Voltage Offset Correction: v_off_ini = -74.298 uV, v_off_fin = -72.526 uV 18:54:20 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -45.273 uVs 18:54:20 Integrated Voltage Measurement... 18:54:29 Voltage Offset Correction: v_off_ini = -64.228 uV, v_off_fin = -69.054 uV 18:54:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.591 uVs 18:54:29 Integrated Voltage Measurement... 18:54:38 Voltage Offset Correction: v_off_ini = -70.354 uV, v_off_fin = -83.411 uV 18:54:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.769 uVs 18:54:39 Integrated Voltage Measurement... 18:54:48 Voltage Offset Correction: v_off_ini = -70.655 uV, v_off_fin = -55.042 uV 18:54:48 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.971 uVs 18:54:50 I2X Average and RMS of Measurements VT = -45.150 +- 6.095 uVs I2X = 4.154 +- 0.561 uTm^2 18:54:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 18:54:55 Integrated Voltage Measurement... 18:55:04 Voltage Offset Correction: v_off_ini = -83.545 uV, v_off_fin = -82.260 uV 18:55:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.945 uVs 18:55:04 Integrated Voltage Measurement... 18:55:13 Voltage Offset Correction: v_off_ini = -88.970 uV, v_off_fin = -86.527 uV 18:55:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.783 uVs 18:55:13 Integrated Voltage Measurement... 18:55:22 Voltage Offset Correction: v_off_ini = -80.826 uV, v_off_fin = -76.543 uV 18:55:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.391 uVs 18:55:22 Integrated Voltage Measurement... 18:55:31 Voltage Offset Correction: v_off_ini = -81.732 uV, v_off_fin = -74.794 uV 18:55:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.199 uVs 18:55:31 Integrated Voltage Measurement... 18:55:40 Voltage Offset Correction: v_off_ini = -84.461 uV, v_off_fin = -74.690 uV 18:55:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.206 uVs 18:55:40 Integrated Voltage Measurement... 18:55:49 Voltage Offset Correction: v_off_ini = -81.376 uV, v_off_fin = -86.887 uV 18:55:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.155 uVs 18:55:52 I2Y Average and RMS of Measurements VT = -269.780 +- 5.448 uVs I2Y = -24.820 +- 0.501 uTm^2 18:55:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:56:00 Integrated Voltage Measurement... 18:56:09 Voltage Offset Correction: v_off_ini = -86.855 uV, v_off_fin = -96.107 uV 18:56:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.232 uVs 18:56:09 Integrated Voltage Measurement... 18:56:18 Voltage Offset Correction: v_off_ini = -92.449 uV, v_off_fin = -65.485 uV 18:56:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.696 uVs 18:56:18 Integrated Voltage Measurement... 18:56:27 Voltage Offset Correction: v_off_ini = -74.952 uV, v_off_fin = -76.279 uV 18:56:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.038 uVs 18:56:27 Integrated Voltage Measurement... 18:56:36 Voltage Offset Correction: v_off_ini = -80.084 uV, v_off_fin = -80.748 uV 18:56:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.034 uVs 18:56:36 Integrated Voltage Measurement... 18:56:45 Voltage Offset Correction: v_off_ini = -95.966 uV, v_off_fin = -97.912 uV 18:56:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.846 uVs 18:56:45 Integrated Voltage Measurement... 18:56:54 Voltage Offset Correction: v_off_ini = -103.336 uV, v_off_fin = -97.423 uV 18:56:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.953 uVs 18:56:58 I1X Average and RMS of Measurements VT = -49.300 +- 4.272 uVs I1X = 9.860 +- 0.854 uTm 18:57:01 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:57:05 Integrated Voltage Measurement... 18:57:14 Voltage Offset Correction: v_off_ini = -79.277 uV, v_off_fin = -103.654 uV 18:57:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -293.268 uVs 18:57:14 Integrated Voltage Measurement... 18:57:23 Voltage Offset Correction: v_off_ini = -78.337 uV, v_off_fin = -68.600 uV 18:57:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 276.922 uVs 18:57:23 Integrated Voltage Measurement... 18:57:32 Voltage Offset Correction: v_off_ini = -94.970 uV, v_off_fin = -104.553 uV 18:57:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -285.808 uVs 18:57:32 Integrated Voltage Measurement... 18:57:41 Voltage Offset Correction: v_off_ini = -85.738 uV, v_off_fin = -72.122 uV 18:57:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 287.636 uVs 18:57:41 Integrated Voltage Measurement... 18:57:50 Voltage Offset Correction: v_off_ini = -69.568 uV, v_off_fin = -97.295 uV 18:57:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -288.381 uVs 18:57:50 Integrated Voltage Measurement... 18:57:59 Voltage Offset Correction: v_off_ini = -88.194 uV, v_off_fin = -66.861 uV 18:57:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 309.909 uVs 18:58:03 I1Y Average and RMS of Measurements VT = -290.321 +- 6.275 uVs I1Y = -58.058 +- 1.255 uTm 18:58:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:58:08 Integrated Voltage Measurement... 18:58:17 Voltage Offset Correction: v_off_ini = -100.272 uV, v_off_fin = -105.617 uV 18:58:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.002 uVs 18:58:17 Integrated Voltage Measurement... 18:58:26 Voltage Offset Correction: v_off_ini = -82.015 uV, v_off_fin = -70.550 uV 18:58:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.861 uVs 18:58:27 Integrated Voltage Measurement... 18:58:36 Voltage Offset Correction: v_off_ini = -79.763 uV, v_off_fin = -77.405 uV 18:58:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.217 uVs 18:58:36 Integrated Voltage Measurement... 18:58:45 Voltage Offset Correction: v_off_ini = -69.616 uV, v_off_fin = -61.100 uV 18:58:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.772 uVs 18:58:45 Integrated Voltage Measurement... 18:58:54 Voltage Offset Correction: v_off_ini = -82.786 uV, v_off_fin = -80.667 uV 18:58:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.069 uVs 18:58:54 Integrated Voltage Measurement... 18:59:03 Voltage Offset Correction: v_off_ini = -82.459 uV, v_off_fin = -69.870 uV 18:59:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.648 uVs 18:59:05 I2X Average and RMS of Measurements VT = -44.595 +- 6.376 uVs I2X = 4.103 +- 0.587 uTm^2 18:59:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 18:59:10 Integrated Voltage Measurement... 18:59:19 Voltage Offset Correction: v_off_ini = -80.514 uV, v_off_fin = -86.740 uV 18:59:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.464 uVs 18:59:19 Integrated Voltage Measurement... 18:59:28 Voltage Offset Correction: v_off_ini = -86.787 uV, v_off_fin = -75.900 uV 18:59:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.240 uVs 18:59:28 Integrated Voltage Measurement... 18:59:37 Voltage Offset Correction: v_off_ini = -78.692 uV, v_off_fin = -75.057 uV 18:59:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.574 uVs 18:59:37 Integrated Voltage Measurement... 18:59:46 Voltage Offset Correction: v_off_ini = -86.077 uV, v_off_fin = -74.163 uV 18:59:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.022 uVs 18:59:46 Integrated Voltage Measurement... 18:59:55 Voltage Offset Correction: v_off_ini = -74.975 uV, v_off_fin = -78.265 uV 18:59:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.114 uVs 18:59:55 Integrated Voltage Measurement... 19:00:04 Voltage Offset Correction: v_off_ini = -64.444 uV, v_off_fin = -86.032 uV 19:00:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.202 uVs 19:00:07 I2Y Average and RMS of Measurements VT = -273.603 +- 5.899 uVs I2Y = -25.171 +- 0.543 uTm^2 19:00:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:00:42 Integrated Voltage Measurement... 19:00:51 Voltage Offset Correction: v_off_ini = -95.796 uV, v_off_fin = -97.328 uV 19:00:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.383 uVs 19:00:51 Integrated Voltage Measurement... 19:01:00 Voltage Offset Correction: v_off_ini = -78.186 uV, v_off_fin = -76.394 uV 19:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.655 uVs 19:01:00 Integrated Voltage Measurement... 19:01:09 Voltage Offset Correction: v_off_ini = -86.285 uV, v_off_fin = -89.374 uV 19:01:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.217 uVs 19:01:09 Integrated Voltage Measurement... 19:01:18 Voltage Offset Correction: v_off_ini = -94.823 uV, v_off_fin = -95.923 uV 19:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 67.984 uVs 19:01:19 Integrated Voltage Measurement... 19:01:27 Voltage Offset Correction: v_off_ini = -99.250 uV, v_off_fin = -91.106 uV 19:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.886 uVs 19:01:28 Integrated Voltage Measurement... 19:01:36 Voltage Offset Correction: v_off_ini = -84.296 uV, v_off_fin = -85.040 uV 19:01:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.275 uVs 19:01:41 I1X Average and RMS of Measurements VT = -67.733 +- 3.781 uVs I1X = 13.547 +- 0.756 uTm 19:01:43 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:01:47 Integrated Voltage Measurement... 19:01:56 Voltage Offset Correction: v_off_ini = -82.701 uV, v_off_fin = -94.981 uV 19:01:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.538 uVs 19:01:56 Integrated Voltage Measurement... 19:02:05 Voltage Offset Correction: v_off_ini = -96.646 uV, v_off_fin = -84.100 uV 19:02:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.502 uVs 19:02:05 Integrated Voltage Measurement... 19:02:14 Voltage Offset Correction: v_off_ini = -92.429 uV, v_off_fin = -114.598 uV 19:02:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.622 uVs 19:02:14 Integrated Voltage Measurement... 19:02:23 Voltage Offset Correction: v_off_ini = -96.129 uV, v_off_fin = -99.706 uV 19:02:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.409 uVs 19:02:24 Integrated Voltage Measurement... 19:02:32 Voltage Offset Correction: v_off_ini = -88.971 uV, v_off_fin = -103.379 uV 19:02:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.738 uVs 19:02:32 Integrated Voltage Measurement... 19:02:41 Voltage Offset Correction: v_off_ini = -90.375 uV, v_off_fin = -65.324 uV 19:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.338 uVs 19:02:46 I1Y Average and RMS of Measurements VT = -246.858 +- 5.030 uVs I1Y = -49.372 +- 1.006 uTm 19:02:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:02:53 Integrated Voltage Measurement... 19:03:02 Voltage Offset Correction: v_off_ini = -87.850 uV, v_off_fin = -86.289 uV 19:03:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.465 uVs 19:03:02 Integrated Voltage Measurement... 19:03:11 Voltage Offset Correction: v_off_ini = -92.762 uV, v_off_fin = -85.722 uV 19:03:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.530 uVs 19:03:11 Integrated Voltage Measurement... 19:03:20 Voltage Offset Correction: v_off_ini = -86.652 uV, v_off_fin = -91.231 uV 19:03:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.523 uVs 19:03:21 Integrated Voltage Measurement... 19:03:30 Voltage Offset Correction: v_off_ini = -67.762 uV, v_off_fin = -57.517 uV 19:03:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.023 uVs 19:03:30 Integrated Voltage Measurement... 19:03:39 Voltage Offset Correction: v_off_ini = -61.545 uV, v_off_fin = -72.458 uV 19:03:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.724 uVs 19:03:39 Integrated Voltage Measurement... 19:03:48 Voltage Offset Correction: v_off_ini = -58.391 uV, v_off_fin = -57.069 uV 19:03:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.651 uVs 19:03:50 I2X Average and RMS of Measurements VT = -46.319 +- 4.277 uVs I2X = 4.261 +- 0.394 uTm^2 19:03:55 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 19:03:58 Integrated Voltage Measurement... 19:04:07 Voltage Offset Correction: v_off_ini = -92.254 uV, v_off_fin = -92.012 uV 19:04:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.978 uVs 19:04:07 Integrated Voltage Measurement... 19:04:16 Voltage Offset Correction: v_off_ini = -84.064 uV, v_off_fin = -75.240 uV 19:04:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.482 uVs 19:04:16 Integrated Voltage Measurement... 19:04:25 Voltage Offset Correction: v_off_ini = -78.442 uV, v_off_fin = -91.237 uV 19:04:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.750 uVs 19:04:25 Integrated Voltage Measurement... 19:04:34 Voltage Offset Correction: v_off_ini = -70.515 uV, v_off_fin = -62.705 uV 19:04:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.539 uVs 19:04:34 Integrated Voltage Measurement... 19:04:43 Voltage Offset Correction: v_off_ini = -75.806 uV, v_off_fin = -78.205 uV 19:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.542 uVs 19:04:43 Integrated Voltage Measurement... 19:04:52 Voltage Offset Correction: v_off_ini = -62.867 uV, v_off_fin = -66.390 uV 19:04:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.282 uVs 19:04:54 I2Y Average and RMS of Measurements VT = -220.595 +- 3.416 uVs I2Y = -20.295 +- 0.314 uTm^2 19:04:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:05:03 Integrated Voltage Measurement... 19:05:12 Voltage Offset Correction: v_off_ini = -76.012 uV, v_off_fin = -87.341 uV 19:05:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.517 uVs 19:05:12 Integrated Voltage Measurement... 19:05:21 Voltage Offset Correction: v_off_ini = -84.977 uV, v_off_fin = -87.337 uV 19:05:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.086 uVs 19:05:21 Integrated Voltage Measurement... 19:05:30 Voltage Offset Correction: v_off_ini = -89.408 uV, v_off_fin = -98.288 uV 19:05:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -77.825 uVs 19:05:30 Integrated Voltage Measurement... 19:05:39 Voltage Offset Correction: v_off_ini = -77.912 uV, v_off_fin = -88.592 uV 19:05:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 47.675 uVs 19:05:39 Integrated Voltage Measurement... 19:05:48 Voltage Offset Correction: v_off_ini = -94.783 uV, v_off_fin = -97.403 uV 19:05:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.409 uVs 19:05:48 Integrated Voltage Measurement... 19:05:57 Voltage Offset Correction: v_off_ini = -100.328 uV, v_off_fin = -91.827 uV 19:05:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 72.293 uVs 19:06:02 I1X Average and RMS of Measurements VT = -65.467 +- 2.290 uVs I1X = 13.095 +- 0.458 uTm 19:06:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:06:08 Integrated Voltage Measurement... 19:06:17 Voltage Offset Correction: v_off_ini = -95.674 uV, v_off_fin = -95.981 uV 19:06:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.983 uVs 19:06:17 Integrated Voltage Measurement... 19:06:26 Voltage Offset Correction: v_off_ini = -112.455 uV, v_off_fin = -104.186 uV 19:06:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.698 uVs 19:06:26 Integrated Voltage Measurement... 19:06:35 Voltage Offset Correction: v_off_ini = -120.898 uV, v_off_fin = -127.246 uV 19:06:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.146 uVs 19:06:35 Integrated Voltage Measurement... 19:06:44 Voltage Offset Correction: v_off_ini = -105.999 uV, v_off_fin = -105.217 uV 19:06:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.329 uVs 19:06:44 Integrated Voltage Measurement... 19:06:53 Voltage Offset Correction: v_off_ini = -98.497 uV, v_off_fin = -111.405 uV 19:06:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.160 uVs 19:06:53 Integrated Voltage Measurement... 19:07:02 Voltage Offset Correction: v_off_ini = -103.559 uV, v_off_fin = -75.688 uV 19:07:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.564 uVs 19:07:07 I1Y Average and RMS of Measurements VT = -241.980 +- 2.044 uVs I1Y = -48.396 +- 0.409 uTm 19:07:12 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:07:14 Integrated Voltage Measurement... 19:07:23 Voltage Offset Correction: v_off_ini = -97.015 uV, v_off_fin = -112.889 uV 19:07:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.083 uVs 19:07:23 Integrated Voltage Measurement... 19:07:32 Voltage Offset Correction: v_off_ini = -90.958 uV, v_off_fin = -81.716 uV 19:07:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.449 uVs 19:07:32 Integrated Voltage Measurement... 19:07:41 Voltage Offset Correction: v_off_ini = -93.459 uV, v_off_fin = -101.442 uV 19:07:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.341 uVs 19:07:41 Integrated Voltage Measurement... 19:07:50 Voltage Offset Correction: v_off_ini = -92.782 uV, v_off_fin = -101.404 uV 19:07:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.177 uVs 19:07:50 Integrated Voltage Measurement... 19:07:59 Voltage Offset Correction: v_off_ini = -101.110 uV, v_off_fin = -114.965 uV 19:07:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.733 uVs 19:07:59 Integrated Voltage Measurement... 19:08:08 Voltage Offset Correction: v_off_ini = -116.972 uV, v_off_fin = -110.326 uV 19:08:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.668 uVs 19:08:11 I2X Average and RMS of Measurements VT = -55.408 +- 9.970 uVs I2X = 5.098 +- 0.917 uTm^2 19:08:16 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 19:08:19 Integrated Voltage Measurement... 19:08:28 Voltage Offset Correction: v_off_ini = -112.185 uV, v_off_fin = -115.800 uV 19:08:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.487 uVs 19:08:28 Integrated Voltage Measurement... 19:08:37 Voltage Offset Correction: v_off_ini = -116.453 uV, v_off_fin = -111.465 uV 19:08:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.182 uVs 19:08:37 Integrated Voltage Measurement... 19:08:46 Voltage Offset Correction: v_off_ini = -119.525 uV, v_off_fin = -116.258 uV 19:08:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.732 uVs 19:08:46 Integrated Voltage Measurement... 19:08:55 Voltage Offset Correction: v_off_ini = -105.612 uV, v_off_fin = -104.937 uV 19:08:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.597 uVs 19:08:55 Integrated Voltage Measurement... 19:09:04 Voltage Offset Correction: v_off_ini = -106.320 uV, v_off_fin = -102.532 uV 19:09:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.336 uVs 19:09:04 Integrated Voltage Measurement... 19:09:13 Voltage Offset Correction: v_off_ini = -114.744 uV, v_off_fin = -110.685 uV 19:09:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.920 uVs 19:09:15 I2Y Average and RMS of Measurements VT = -220.042 +- 8.396 uVs I2Y = -20.244 +- 0.772 uTm^2 19:09:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:09:24 Integrated Voltage Measurement... 19:09:33 Voltage Offset Correction: v_off_ini = -103.023 uV, v_off_fin = -128.773 uV 19:09:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.428 uVs 19:09:33 Integrated Voltage Measurement... 19:09:42 Voltage Offset Correction: v_off_ini = -116.536 uV, v_off_fin = -106.311 uV 19:09:42 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.903 uVs 19:09:42 Integrated Voltage Measurement... 19:09:51 Voltage Offset Correction: v_off_ini = -108.329 uV, v_off_fin = -96.831 uV 19:09:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.735 uVs 19:09:51 Integrated Voltage Measurement... 19:10:00 Voltage Offset Correction: v_off_ini = -96.964 uV, v_off_fin = -108.406 uV 19:10:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.109 uVs 19:10:00 Integrated Voltage Measurement... 19:10:09 Voltage Offset Correction: v_off_ini = -118.217 uV, v_off_fin = -111.245 uV 19:10:09 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.063 uVs 19:10:09 Integrated Voltage Measurement... 19:10:18 Voltage Offset Correction: v_off_ini = -127.130 uV, v_off_fin = -113.560 uV 19:10:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 75.066 uVs 19:10:23 I1X Average and RMS of Measurements VT = -77.718 +- 3.411 uVs I1X = 15.544 +- 0.683 uTm 19:10:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:10:29 Integrated Voltage Measurement... 19:10:38 Voltage Offset Correction: v_off_ini = -126.175 uV, v_off_fin = -121.360 uV 19:10:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.223 uVs 19:10:38 Integrated Voltage Measurement... 19:10:47 Voltage Offset Correction: v_off_ini = -104.200 uV, v_off_fin = -120.480 uV 19:10:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.273 uVs 19:10:47 Integrated Voltage Measurement... 19:10:56 Voltage Offset Correction: v_off_ini = -126.367 uV, v_off_fin = -145.193 uV 19:10:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.413 uVs 19:10:56 Integrated Voltage Measurement... 19:11:05 Voltage Offset Correction: v_off_ini = -145.022 uV, v_off_fin = -113.668 uV 19:11:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.966 uVs 19:11:05 Integrated Voltage Measurement... 19:11:14 Voltage Offset Correction: v_off_ini = -100.547 uV, v_off_fin = -114.309 uV 19:11:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.466 uVs 19:11:14 Integrated Voltage Measurement... 19:11:23 Voltage Offset Correction: v_off_ini = -112.366 uV, v_off_fin = -106.825 uV 19:11:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.347 uVs 19:11:28 I1Y Average and RMS of Measurements VT = -239.781 +- 5.240 uVs I1Y = -47.956 +- 1.048 uTm 19:11:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:11:35 Integrated Voltage Measurement... 19:11:44 Voltage Offset Correction: v_off_ini = -124.443 uV, v_off_fin = -126.918 uV 19:11:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.424 uVs 19:11:44 Integrated Voltage Measurement... 19:11:53 Voltage Offset Correction: v_off_ini = -109.470 uV, v_off_fin = -101.911 uV 19:11:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.724 uVs 19:11:53 Integrated Voltage Measurement... 19:12:02 Voltage Offset Correction: v_off_ini = -114.531 uV, v_off_fin = -106.429 uV 19:12:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.397 uVs 19:12:02 Integrated Voltage Measurement... 19:12:11 Voltage Offset Correction: v_off_ini = -112.593 uV, v_off_fin = -103.026 uV 19:12:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.033 uVs 19:12:11 Integrated Voltage Measurement... 19:12:20 Voltage Offset Correction: v_off_ini = -117.970 uV, v_off_fin = -124.870 uV 19:12:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.834 uVs 19:12:20 Integrated Voltage Measurement... 19:12:29 Voltage Offset Correction: v_off_ini = -126.095 uV, v_off_fin = -130.107 uV 19:12:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.294 uVs 19:12:32 I2X Average and RMS of Measurements VT = -60.618 +- 5.563 uVs I2X = 5.577 +- 0.512 uTm^2 19:12:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:12:40 Integrated Voltage Measurement... 19:12:49 Voltage Offset Correction: v_off_ini = -131.765 uV, v_off_fin = -135.455 uV 19:12:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.927 uVs 19:12:49 Integrated Voltage Measurement... 19:12:58 Voltage Offset Correction: v_off_ini = -109.113 uV, v_off_fin = -106.486 uV 19:12:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.075 uVs 19:12:58 Integrated Voltage Measurement... 19:13:07 Voltage Offset Correction: v_off_ini = -99.405 uV, v_off_fin = -123.924 uV 19:13:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.588 uVs 19:13:07 Integrated Voltage Measurement... 19:13:16 Voltage Offset Correction: v_off_ini = -128.421 uV, v_off_fin = -115.556 uV 19:13:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.588 uVs 19:13:16 Integrated Voltage Measurement... 19:13:25 Voltage Offset Correction: v_off_ini = -128.602 uV, v_off_fin = -128.073 uV 19:13:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.125 uVs 19:13:25 Integrated Voltage Measurement... 19:13:34 Voltage Offset Correction: v_off_ini = -112.739 uV, v_off_fin = -104.389 uV 19:13:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.410 uVs 19:13:36 I2Y Average and RMS of Measurements VT = -223.452 +- 4.214 uVs I2Y = -20.558 +- 0.388 uTm^2 19:13:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:13:45 Integrated Voltage Measurement... 19:13:54 Voltage Offset Correction: v_off_ini = -121.372 uV, v_off_fin = -120.688 uV 19:13:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -79.691 uVs 19:13:54 Integrated Voltage Measurement... 19:14:03 Voltage Offset Correction: v_off_ini = -123.539 uV, v_off_fin = -110.614 uV 19:14:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.901 uVs 19:14:03 Integrated Voltage Measurement... 19:14:12 Voltage Offset Correction: v_off_ini = -100.379 uV, v_off_fin = -107.231 uV 19:14:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.392 uVs 19:14:12 Integrated Voltage Measurement... 19:14:21 Voltage Offset Correction: v_off_ini = -99.163 uV, v_off_fin = -111.973 uV 19:14:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.165 uVs 19:14:21 Integrated Voltage Measurement... 19:14:30 Voltage Offset Correction: v_off_ini = -103.883 uV, v_off_fin = -107.371 uV 19:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.337 uVs 19:14:30 Integrated Voltage Measurement... 19:14:39 Voltage Offset Correction: v_off_ini = -102.607 uV, v_off_fin = -102.061 uV 19:14:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.914 uVs 19:14:44 I1X Average and RMS of Measurements VT = -67.067 +- 11.303 uVs I1X = 13.414 +- 2.261 uTm 19:14:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:14:50 Integrated Voltage Measurement... 19:14:59 Voltage Offset Correction: v_off_ini = -110.190 uV, v_off_fin = -120.349 uV 19:14:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.007 uVs 19:14:59 Integrated Voltage Measurement... 19:15:08 Voltage Offset Correction: v_off_ini = -102.978 uV, v_off_fin = -101.083 uV 19:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.333 uVs 19:15:08 Integrated Voltage Measurement... 19:15:17 Voltage Offset Correction: v_off_ini = -104.220 uV, v_off_fin = -114.123 uV 19:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.197 uVs 19:15:17 Integrated Voltage Measurement... 19:15:26 Voltage Offset Correction: v_off_ini = -109.068 uV, v_off_fin = -101.681 uV 19:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.276 uVs 19:15:26 Integrated Voltage Measurement... 19:15:35 Voltage Offset Correction: v_off_ini = -110.459 uV, v_off_fin = -113.121 uV 19:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.580 uVs 19:15:35 Integrated Voltage Measurement... 19:15:44 Voltage Offset Correction: v_off_ini = -105.688 uV, v_off_fin = -93.334 uV 19:15:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.225 uVs 19:15:49 I1Y Average and RMS of Measurements VT = -236.936 +- 10.297 uVs I1Y = -47.388 +- 2.059 uTm 19:15:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:15:56 Integrated Voltage Measurement... 19:16:05 Voltage Offset Correction: v_off_ini = -82.128 uV, v_off_fin = -100.645 uV 19:16:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.581 uVs 19:16:05 Integrated Voltage Measurement... 19:16:14 Voltage Offset Correction: v_off_ini = -93.622 uV, v_off_fin = -100.527 uV 19:16:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.404 uVs 19:16:14 Integrated Voltage Measurement... 19:16:23 Voltage Offset Correction: v_off_ini = -94.583 uV, v_off_fin = -107.525 uV 19:16:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.935 uVs 19:16:23 Integrated Voltage Measurement... 19:16:32 Voltage Offset Correction: v_off_ini = -102.386 uV, v_off_fin = -88.321 uV 19:16:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.226 uVs 19:16:32 Integrated Voltage Measurement... 19:16:41 Voltage Offset Correction: v_off_ini = -91.165 uV, v_off_fin = -105.313 uV 19:16:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.386 uVs 19:16:42 Integrated Voltage Measurement... 19:16:50 Voltage Offset Correction: v_off_ini = -84.232 uV, v_off_fin = -70.743 uV 19:16:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.299 uVs 19:16:53 I2X Average and RMS of Measurements VT = -62.139 +- 8.164 uVs I2X = 5.717 +- 0.751 uTm^2 19:16:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 19:17:01 Integrated Voltage Measurement... 19:17:10 Voltage Offset Correction: v_off_ini = -102.986 uV, v_off_fin = -103.074 uV 19:17:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.621 uVs 19:17:10 Integrated Voltage Measurement... 19:17:19 Voltage Offset Correction: v_off_ini = -109.403 uV, v_off_fin = -120.313 uV 19:17:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.660 uVs 19:17:19 Integrated Voltage Measurement... 19:17:28 Voltage Offset Correction: v_off_ini = -105.508 uV, v_off_fin = -106.734 uV 19:17:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.564 uVs 19:17:28 Integrated Voltage Measurement... 19:17:37 Voltage Offset Correction: v_off_ini = -119.280 uV, v_off_fin = -100.043 uV 19:17:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.358 uVs 19:17:37 Integrated Voltage Measurement... 19:17:46 Voltage Offset Correction: v_off_ini = -119.819 uV, v_off_fin = -111.183 uV 19:17:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.174 uVs 19:17:46 Integrated Voltage Measurement... 19:17:55 Voltage Offset Correction: v_off_ini = -114.556 uV, v_off_fin = -112.968 uV 19:17:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 233.908 uVs 19:17:57 I2Y Average and RMS of Measurements VT = -220.548 +- 8.557 uVs I2Y = -20.291 +- 0.788 uTm^2 19:18:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:18:06 Integrated Voltage Measurement... 19:18:15 Voltage Offset Correction: v_off_ini = -104.953 uV, v_off_fin = -111.983 uV 19:18:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.865 uVs 19:18:15 Integrated Voltage Measurement... 19:18:24 Voltage Offset Correction: v_off_ini = -106.374 uV, v_off_fin = -109.807 uV 19:18:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.400 uVs 19:18:24 Integrated Voltage Measurement... 19:18:33 Voltage Offset Correction: v_off_ini = -107.687 uV, v_off_fin = -118.510 uV 19:18:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -74.307 uVs 19:18:33 Integrated Voltage Measurement... 19:18:42 Voltage Offset Correction: v_off_ini = -93.955 uV, v_off_fin = -94.689 uV 19:18:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.319 uVs 19:18:42 Integrated Voltage Measurement... 19:18:51 Voltage Offset Correction: v_off_ini = -102.130 uV, v_off_fin = -106.399 uV 19:18:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.040 uVs 19:18:51 Integrated Voltage Measurement... 19:19:00 Voltage Offset Correction: v_off_ini = -87.373 uV, v_off_fin = -93.142 uV 19:19:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.278 uVs 19:19:04 I1X Average and RMS of Measurements VT = -70.535 +- 3.098 uVs I1X = 14.107 +- 0.619 uTm 19:19:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:19:11 Integrated Voltage Measurement... 19:19:20 Voltage Offset Correction: v_off_ini = -116.727 uV, v_off_fin = -123.895 uV 19:19:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.155 uVs 19:19:20 Integrated Voltage Measurement... 19:19:29 Voltage Offset Correction: v_off_ini = -108.739 uV, v_off_fin = -113.951 uV 19:19:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.257 uVs 19:19:29 Integrated Voltage Measurement... 19:19:38 Voltage Offset Correction: v_off_ini = -114.836 uV, v_off_fin = -116.997 uV 19:19:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.796 uVs 19:19:38 Integrated Voltage Measurement... 19:19:47 Voltage Offset Correction: v_off_ini = -115.965 uV, v_off_fin = -103.085 uV 19:19:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.683 uVs 19:19:47 Integrated Voltage Measurement... 19:19:56 Voltage Offset Correction: v_off_ini = -109.668 uV, v_off_fin = -112.271 uV 19:19:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.662 uVs 19:19:56 Integrated Voltage Measurement... 19:20:05 Voltage Offset Correction: v_off_ini = -109.218 uV, v_off_fin = -76.846 uV 19:20:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.870 uVs 19:20:09 I1Y Average and RMS of Measurements VT = -239.237 +- 5.694 uVs I1Y = -47.847 +- 1.139 uTm 19:20:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:20:17 Integrated Voltage Measurement... 19:20:26 Voltage Offset Correction: v_off_ini = -106.714 uV, v_off_fin = -114.219 uV 19:20:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -85.856 uVs 19:20:26 Integrated Voltage Measurement... 19:20:35 Voltage Offset Correction: v_off_ini = -113.294 uV, v_off_fin = -108.476 uV 19:20:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.104 uVs 19:20:35 Integrated Voltage Measurement... 19:20:44 Voltage Offset Correction: v_off_ini = -110.719 uV, v_off_fin = -113.428 uV 19:20:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.579 uVs 19:20:44 Integrated Voltage Measurement... 19:20:53 Voltage Offset Correction: v_off_ini = -117.091 uV, v_off_fin = -103.744 uV 19:20:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.303 uVs 19:20:53 Integrated Voltage Measurement... 19:21:02 Voltage Offset Correction: v_off_ini = -124.750 uV, v_off_fin = -110.087 uV 19:21:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -64.685 uVs 19:21:02 Integrated Voltage Measurement... 19:21:11 Voltage Offset Correction: v_off_ini = -111.448 uV, v_off_fin = -90.194 uV 19:21:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.147 uVs 19:21:14 I2X Average and RMS of Measurements VT = -71.779 +- 6.663 uVs I2X = 6.604 +- 0.613 uTm^2 19:21:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 19:21:22 Integrated Voltage Measurement... 19:21:31 Voltage Offset Correction: v_off_ini = -106.447 uV, v_off_fin = -95.612 uV 19:21:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.185 uVs 19:21:31 Integrated Voltage Measurement... 19:21:40 Voltage Offset Correction: v_off_ini = -110.446 uV, v_off_fin = -103.622 uV 19:21:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.591 uVs 19:21:40 Integrated Voltage Measurement... 19:21:49 Voltage Offset Correction: v_off_ini = -108.993 uV, v_off_fin = -101.333 uV 19:21:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.248 uVs 19:21:49 Integrated Voltage Measurement... 19:21:58 Voltage Offset Correction: v_off_ini = -113.563 uV, v_off_fin = -118.484 uV 19:21:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.540 uVs 19:21:58 Integrated Voltage Measurement... 19:22:07 Voltage Offset Correction: v_off_ini = -99.575 uV, v_off_fin = -90.517 uV 19:22:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.119 uVs 19:22:07 Integrated Voltage Measurement... 19:22:16 Voltage Offset Correction: v_off_ini = -87.145 uV, v_off_fin = -89.652 uV 19:22:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.929 uVs 19:22:18 I2Y Average and RMS of Measurements VT = -229.102 +- 4.129 uVs I2Y = -21.077 +- 0.380 uTm^2 19:22:26 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:22:30 Integrated Voltage Measurement... 19:22:39 Voltage Offset Correction: v_off_ini = -88.146 uV, v_off_fin = -91.824 uV 19:22:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.239 uVs 19:22:39 Integrated Voltage Measurement... 19:22:48 Voltage Offset Correction: v_off_ini = -93.594 uV, v_off_fin = -96.676 uV 19:22:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.056 uVs 19:22:48 Integrated Voltage Measurement... 19:22:57 Voltage Offset Correction: v_off_ini = -88.823 uV, v_off_fin = -105.422 uV 19:22:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.569 uVs 19:22:57 Integrated Voltage Measurement... 19:23:06 Voltage Offset Correction: v_off_ini = -109.938 uV, v_off_fin = -108.952 uV 19:23:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 77.067 uVs 19:23:06 Integrated Voltage Measurement... 19:23:15 Voltage Offset Correction: v_off_ini = -94.741 uV, v_off_fin = -101.743 uV 19:23:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.307 uVs 19:23:15 Integrated Voltage Measurement... 19:23:24 Voltage Offset Correction: v_off_ini = -99.499 uV, v_off_fin = -108.131 uV 19:23:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.051 uVs 19:23:28 I1X Average and RMS of Measurements VT = -65.048 +- 5.857 uVs I1X = 13.010 +- 1.172 uTm 19:23:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:23:35 Integrated Voltage Measurement... 19:23:44 Voltage Offset Correction: v_off_ini = -106.771 uV, v_off_fin = -106.200 uV 19:23:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.714 uVs 19:23:44 Integrated Voltage Measurement... 19:23:53 Voltage Offset Correction: v_off_ini = -71.790 uV, v_off_fin = -70.534 uV 19:23:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.007 uVs 19:23:53 Integrated Voltage Measurement... 19:24:02 Voltage Offset Correction: v_off_ini = -83.155 uV, v_off_fin = -101.722 uV 19:24:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.590 uVs 19:24:02 Integrated Voltage Measurement... 19:24:11 Voltage Offset Correction: v_off_ini = -92.719 uV, v_off_fin = -83.973 uV 19:24:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.740 uVs 19:24:11 Integrated Voltage Measurement... 19:24:20 Voltage Offset Correction: v_off_ini = -100.381 uV, v_off_fin = -108.619 uV 19:24:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.190 uVs 19:24:20 Integrated Voltage Measurement... 19:24:29 Voltage Offset Correction: v_off_ini = -91.924 uV, v_off_fin = -83.711 uV 19:24:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.614 uVs 19:24:33 I1Y Average and RMS of Measurements VT = -234.143 +- 2.865 uVs I1Y = -46.829 +- 0.573 uTm 19:24:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:24:39 Integrated Voltage Measurement... 19:24:48 Voltage Offset Correction: v_off_ini = -96.945 uV, v_off_fin = -105.219 uV 19:24:48 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -32.841 uVs 19:24:48 Integrated Voltage Measurement... 19:24:57 Voltage Offset Correction: v_off_ini = -94.213 uV, v_off_fin = -86.515 uV 19:24:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.004 uVs 19:24:57 Integrated Voltage Measurement... 19:25:06 Voltage Offset Correction: v_off_ini = -88.852 uV, v_off_fin = -91.083 uV 19:25:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.769 uVs 19:25:06 Integrated Voltage Measurement... 19:25:15 Voltage Offset Correction: v_off_ini = -100.855 uV, v_off_fin = -85.013 uV 19:25:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.483 uVs 19:25:15 Integrated Voltage Measurement... 19:25:24 Voltage Offset Correction: v_off_ini = -88.740 uV, v_off_fin = -105.236 uV 19:25:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.301 uVs 19:25:24 Integrated Voltage Measurement... 19:25:33 Voltage Offset Correction: v_off_ini = -79.849 uV, v_off_fin = -81.368 uV 19:25:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.741 uVs 19:25:35 I2X Average and RMS of Measurements VT = -52.690 +- 8.798 uVs I2X = 4.847 +- 0.810 uTm^2 19:25:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 19:25:40 Integrated Voltage Measurement... 19:25:49 Voltage Offset Correction: v_off_ini = -107.010 uV, v_off_fin = -117.042 uV 19:25:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.402 uVs 19:25:49 Integrated Voltage Measurement... 19:25:58 Voltage Offset Correction: v_off_ini = -105.429 uV, v_off_fin = -132.906 uV 19:25:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.578 uVs 19:25:58 Integrated Voltage Measurement... 19:26:07 Voltage Offset Correction: v_off_ini = -121.569 uV, v_off_fin = -109.674 uV 19:26:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.579 uVs 19:26:07 Integrated Voltage Measurement... 19:26:16 Voltage Offset Correction: v_off_ini = -117.179 uV, v_off_fin = -103.822 uV 19:26:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.070 uVs 19:26:17 Integrated Voltage Measurement... 19:26:26 Voltage Offset Correction: v_off_ini = -100.601 uV, v_off_fin = -109.690 uV 19:26:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.852 uVs 19:26:26 Integrated Voltage Measurement... 19:26:35 Voltage Offset Correction: v_off_ini = -114.743 uV, v_off_fin = -103.071 uV 19:26:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.625 uVs 19:26:37 I2Y Average and RMS of Measurements VT = -214.518 +- 7.553 uVs I2Y = -19.736 +- 0.695 uTm^2 19:26:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:26:45 Integrated Voltage Measurement... 19:26:54 Voltage Offset Correction: v_off_ini = -110.587 uV, v_off_fin = -117.960 uV 19:26:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -80.498 uVs 19:26:54 Integrated Voltage Measurement... 19:27:03 Voltage Offset Correction: v_off_ini = -118.195 uV, v_off_fin = -100.251 uV 19:27:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.138 uVs 19:27:03 Integrated Voltage Measurement... 19:27:12 Voltage Offset Correction: v_off_ini = -110.812 uV, v_off_fin = -110.409 uV 19:27:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.215 uVs 19:27:12 Integrated Voltage Measurement... 19:27:21 Voltage Offset Correction: v_off_ini = -125.345 uV, v_off_fin = -107.281 uV 19:27:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.513 uVs 19:27:21 Integrated Voltage Measurement... 19:27:30 Voltage Offset Correction: v_off_ini = -109.537 uV, v_off_fin = -117.763 uV 19:27:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.676 uVs 19:27:30 Integrated Voltage Measurement... 19:27:39 Voltage Offset Correction: v_off_ini = -120.902 uV, v_off_fin = -124.792 uV 19:27:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.516 uVs 19:27:44 I1X Average and RMS of Measurements VT = -66.759 +- 9.634 uVs I1X = 13.352 +- 1.927 uTm 19:27:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:27:50 Integrated Voltage Measurement... 19:27:59 Voltage Offset Correction: v_off_ini = -115.699 uV, v_off_fin = -117.904 uV 19:27:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.033 uVs 19:27:59 Integrated Voltage Measurement... 19:28:08 Voltage Offset Correction: v_off_ini = -109.885 uV, v_off_fin = -81.750 uV 19:28:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.851 uVs 19:28:08 Integrated Voltage Measurement... 19:28:17 Voltage Offset Correction: v_off_ini = -112.650 uV, v_off_fin = -119.879 uV 19:28:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.962 uVs 19:28:17 Integrated Voltage Measurement... 19:28:26 Voltage Offset Correction: v_off_ini = -101.318 uV, v_off_fin = -94.708 uV 19:28:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.074 uVs 19:28:26 Integrated Voltage Measurement... 19:28:35 Voltage Offset Correction: v_off_ini = -91.301 uV, v_off_fin = -105.179 uV 19:28:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.159 uVs 19:28:35 Integrated Voltage Measurement... 19:28:44 Voltage Offset Correction: v_off_ini = -80.308 uV, v_off_fin = -90.685 uV 19:28:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.312 uVs 19:28:49 I1Y Average and RMS of Measurements VT = -242.399 +- 5.686 uVs I1Y = -48.480 +- 1.137 uTm 19:28:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:28:54 Integrated Voltage Measurement... 19:29:03 Voltage Offset Correction: v_off_ini = -108.732 uV, v_off_fin = -104.385 uV 19:29:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.849 uVs 19:29:03 Integrated Voltage Measurement... 19:29:12 Voltage Offset Correction: v_off_ini = -90.822 uV, v_off_fin = -79.357 uV 19:29:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.492 uVs 19:29:12 Integrated Voltage Measurement... 19:29:21 Voltage Offset Correction: v_off_ini = -82.127 uV, v_off_fin = -105.886 uV 19:29:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.646 uVs 19:29:21 Integrated Voltage Measurement... 19:29:30 Voltage Offset Correction: v_off_ini = -81.054 uV, v_off_fin = -69.570 uV 19:29:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.969 uVs 19:29:30 Integrated Voltage Measurement... 19:29:39 Voltage Offset Correction: v_off_ini = -75.120 uV, v_off_fin = -93.279 uV 19:29:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.146 uVs 19:29:39 Integrated Voltage Measurement... 19:29:48 Voltage Offset Correction: v_off_ini = -87.461 uV, v_off_fin = -89.629 uV 19:29:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.585 uVs 19:29:50 I2X Average and RMS of Measurements VT = -62.781 +- 8.298 uVs I2X = 5.776 +- 0.763 uTm^2 19:29:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 19:29:55 Integrated Voltage Measurement... 19:30:04 Voltage Offset Correction: v_off_ini = -88.469 uV, v_off_fin = -90.996 uV 19:30:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.597 uVs 19:30:05 Integrated Voltage Measurement... 19:30:14 Voltage Offset Correction: v_off_ini = -91.579 uV, v_off_fin = -95.205 uV 19:30:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.798 uVs 19:30:14 Integrated Voltage Measurement... 19:30:23 Voltage Offset Correction: v_off_ini = -93.412 uV, v_off_fin = -95.791 uV 19:30:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.806 uVs 19:30:23 Integrated Voltage Measurement... 19:30:32 Voltage Offset Correction: v_off_ini = -97.169 uV, v_off_fin = -86.083 uV 19:30:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.137 uVs 19:30:32 Integrated Voltage Measurement... 19:30:41 Voltage Offset Correction: v_off_ini = -92.779 uV, v_off_fin = -85.709 uV 19:30:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.081 uVs 19:30:41 Integrated Voltage Measurement... 19:30:50 Voltage Offset Correction: v_off_ini = -75.748 uV, v_off_fin = -89.706 uV 19:30:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.412 uVs 19:30:52 I2Y Average and RMS of Measurements VT = -220.972 +- 5.838 uVs I2Y = -20.329 +- 0.537 uTm^2 19:30:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:31:00 Integrated Voltage Measurement... 19:31:09 Voltage Offset Correction: v_off_ini = -95.984 uV, v_off_fin = -101.901 uV 19:31:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.497 uVs 19:31:09 Integrated Voltage Measurement... 19:31:18 Voltage Offset Correction: v_off_ini = -92.835 uV, v_off_fin = -74.076 uV 19:31:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.745 uVs 19:31:19 Integrated Voltage Measurement... 19:31:27 Voltage Offset Correction: v_off_ini = -85.532 uV, v_off_fin = -95.774 uV 19:31:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.920 uVs 19:31:27 Integrated Voltage Measurement... 19:31:36 Voltage Offset Correction: v_off_ini = -74.856 uV, v_off_fin = -84.466 uV 19:31:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.184 uVs 19:31:37 Integrated Voltage Measurement... 19:31:45 Voltage Offset Correction: v_off_ini = -98.150 uV, v_off_fin = -88.918 uV 19:31:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.007 uVs 19:31:46 Integrated Voltage Measurement... 19:31:54 Voltage Offset Correction: v_off_ini = -91.879 uV, v_off_fin = -86.704 uV 19:31:55 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.619 uVs 19:31:59 I1X Average and RMS of Measurements VT = -73.662 +- 10.704 uVs I1X = 14.733 +- 2.141 uTm 19:32:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:32:06 Integrated Voltage Measurement... 19:32:14 Voltage Offset Correction: v_off_ini = -71.383 uV, v_off_fin = -79.189 uV 19:32:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.374 uVs 19:32:14 Integrated Voltage Measurement... 19:32:23 Voltage Offset Correction: v_off_ini = -66.877 uV, v_off_fin = -56.755 uV 19:32:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.142 uVs 19:32:23 Integrated Voltage Measurement... 19:32:32 Voltage Offset Correction: v_off_ini = -59.706 uV, v_off_fin = -67.215 uV 19:32:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.790 uVs 19:32:32 Integrated Voltage Measurement... 19:32:41 Voltage Offset Correction: v_off_ini = -76.433 uV, v_off_fin = -63.436 uV 19:32:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.919 uVs 19:32:41 Integrated Voltage Measurement... 19:32:50 Voltage Offset Correction: v_off_ini = -74.132 uV, v_off_fin = -93.854 uV 19:32:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.597 uVs 19:32:50 Integrated Voltage Measurement... 19:32:59 Voltage Offset Correction: v_off_ini = -89.262 uV, v_off_fin = -71.463 uV 19:32:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.391 uVs 19:33:04 I1Y Average and RMS of Measurements VT = -238.369 +- 2.033 uVs I1Y = -47.674 +- 0.407 uTm 19:33:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:33:09 Integrated Voltage Measurement... 19:33:18 Voltage Offset Correction: v_off_ini = -66.739 uV, v_off_fin = -75.969 uV 19:33:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.632 uVs 19:33:18 Integrated Voltage Measurement... 19:33:27 Voltage Offset Correction: v_off_ini = -68.893 uV, v_off_fin = -60.732 uV 19:33:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.368 uVs 19:33:27 Integrated Voltage Measurement... 19:33:36 Voltage Offset Correction: v_off_ini = -78.619 uV, v_off_fin = -76.932 uV 19:33:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.139 uVs 19:33:36 Integrated Voltage Measurement... 19:33:45 Voltage Offset Correction: v_off_ini = -75.431 uV, v_off_fin = -71.005 uV 19:33:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.097 uVs 19:33:45 Integrated Voltage Measurement... 19:33:54 Voltage Offset Correction: v_off_ini = -82.777 uV, v_off_fin = -96.939 uV 19:33:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.621 uVs 19:33:54 Integrated Voltage Measurement... 19:34:03 Voltage Offset Correction: v_off_ini = -79.674 uV, v_off_fin = -66.017 uV 19:34:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.186 uVs 19:34:05 I2X Average and RMS of Measurements VT = -59.674 +- 6.230 uVs I2X = 5.490 +- 0.573 uTm^2 19:34:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 19:34:10 Integrated Voltage Measurement... 19:34:19 Voltage Offset Correction: v_off_ini = -81.581 uV, v_off_fin = -80.704 uV 19:34:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.982 uVs 19:34:19 Integrated Voltage Measurement... 19:34:28 Voltage Offset Correction: v_off_ini = -69.386 uV, v_off_fin = -81.457 uV 19:34:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.040 uVs 19:34:28 Integrated Voltage Measurement... 19:34:37 Voltage Offset Correction: v_off_ini = -74.324 uV, v_off_fin = -82.091 uV 19:34:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.705 uVs 19:34:38 Integrated Voltage Measurement... 19:34:46 Voltage Offset Correction: v_off_ini = -89.888 uV, v_off_fin = -95.610 uV 19:34:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.902 uVs 19:34:47 Integrated Voltage Measurement... 19:34:56 Voltage Offset Correction: v_off_ini = -90.690 uV, v_off_fin = -87.344 uV 19:34:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.949 uVs 19:34:56 Integrated Voltage Measurement... 19:35:05 Voltage Offset Correction: v_off_ini = -81.096 uV, v_off_fin = -96.296 uV 19:35:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.083 uVs 19:35:07 I2Y Average and RMS of Measurements VT = -220.610 +- 5.591 uVs I2Y = -20.296 +- 0.514 uTm^2 19:35:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:35:15 Integrated Voltage Measurement... 19:35:24 Voltage Offset Correction: v_off_ini = -87.820 uV, v_off_fin = -90.600 uV 19:35:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -79.386 uVs 19:35:24 Integrated Voltage Measurement... 19:35:33 Voltage Offset Correction: v_off_ini = -91.434 uV, v_off_fin = -96.873 uV 19:35:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.182 uVs 19:35:33 Integrated Voltage Measurement... 19:35:42 Voltage Offset Correction: v_off_ini = -93.117 uV, v_off_fin = -105.062 uV 19:35:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.096 uVs 19:35:42 Integrated Voltage Measurement... 19:35:51 Voltage Offset Correction: v_off_ini = -99.270 uV, v_off_fin = -95.140 uV 19:35:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.072 uVs 19:35:51 Integrated Voltage Measurement... 19:36:00 Voltage Offset Correction: v_off_ini = -100.090 uV, v_off_fin = -107.143 uV 19:36:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.470 uVs 19:36:00 Integrated Voltage Measurement... 19:36:09 Voltage Offset Correction: v_off_ini = -99.850 uV, v_off_fin = -105.855 uV 19:36:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.223 uVs 19:36:14 I1X Average and RMS of Measurements VT = -77.572 +- 3.310 uVs I1X = 15.515 +- 0.662 uTm 19:36:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:36:20 Integrated Voltage Measurement... 19:36:29 Voltage Offset Correction: v_off_ini = -109.840 uV, v_off_fin = -115.979 uV 19:36:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.661 uVs 19:36:29 Integrated Voltage Measurement... 19:36:38 Voltage Offset Correction: v_off_ini = -96.247 uV, v_off_fin = -81.968 uV 19:36:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.015 uVs 19:36:39 Integrated Voltage Measurement... 19:36:47 Voltage Offset Correction: v_off_ini = -115.035 uV, v_off_fin = -115.569 uV 19:36:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.302 uVs 19:36:47 Integrated Voltage Measurement... 19:36:56 Voltage Offset Correction: v_off_ini = -112.840 uV, v_off_fin = -100.961 uV 19:36:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.486 uVs 19:36:56 Integrated Voltage Measurement... 19:37:05 Voltage Offset Correction: v_off_ini = -102.578 uV, v_off_fin = -118.747 uV 19:37:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.075 uVs 19:37:05 Integrated Voltage Measurement... 19:37:14 Voltage Offset Correction: v_off_ini = -113.936 uV, v_off_fin = -98.522 uV 19:37:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.572 uVs 19:37:19 I1Y Average and RMS of Measurements VT = -237.852 +- 6.800 uVs I1Y = -47.570 +- 1.360 uTm 19:37:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:37:24 Integrated Voltage Measurement... 19:37:33 Voltage Offset Correction: v_off_ini = -120.482 uV, v_off_fin = -131.598 uV 19:37:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -75.014 uVs 19:37:33 Integrated Voltage Measurement... 19:37:42 Voltage Offset Correction: v_off_ini = -117.901 uV, v_off_fin = -102.407 uV 19:37:42 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 56.959 uVs 19:37:42 Integrated Voltage Measurement... 19:37:51 Voltage Offset Correction: v_off_ini = -126.861 uV, v_off_fin = -127.229 uV 19:37:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.631 uVs 19:37:51 Integrated Voltage Measurement... 19:38:00 Voltage Offset Correction: v_off_ini = -119.428 uV, v_off_fin = -97.606 uV 19:38:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.806 uVs 19:38:00 Integrated Voltage Measurement... 19:38:09 Voltage Offset Correction: v_off_ini = -120.356 uV, v_off_fin = -125.365 uV 19:38:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.607 uVs 19:38:09 Integrated Voltage Measurement... 19:38:18 Voltage Offset Correction: v_off_ini = -112.804 uV, v_off_fin = -113.206 uV 19:38:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.888 uVs 19:38:20 I2X Average and RMS of Measurements VT = -70.818 +- 3.625 uVs I2X = 6.515 +- 0.333 uTm^2 19:38:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 19:38:26 Integrated Voltage Measurement... 19:38:34 Voltage Offset Correction: v_off_ini = -121.743 uV, v_off_fin = -108.684 uV 19:38:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.943 uVs 19:38:35 Integrated Voltage Measurement... 19:38:44 Voltage Offset Correction: v_off_ini = -103.306 uV, v_off_fin = -119.092 uV 19:38:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.459 uVs 19:38:44 Integrated Voltage Measurement... 19:38:53 Voltage Offset Correction: v_off_ini = -108.683 uV, v_off_fin = -113.307 uV 19:38:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.232 uVs 19:38:53 Integrated Voltage Measurement... 19:39:02 Voltage Offset Correction: v_off_ini = -100.917 uV, v_off_fin = -110.586 uV 19:39:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 207.218 uVs 19:39:02 Integrated Voltage Measurement... 19:39:11 Voltage Offset Correction: v_off_ini = -99.132 uV, v_off_fin = -112.959 uV 19:39:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.638 uVs 19:39:11 Integrated Voltage Measurement... 19:39:20 Voltage Offset Correction: v_off_ini = -113.525 uV, v_off_fin = -101.543 uV 19:39:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.050 uVs 19:39:22 I2Y Average and RMS of Measurements VT = -230.757 +- 11.951 uVs I2Y = -21.230 +- 1.099 uTm^2 19:39:26 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:39:30 Integrated Voltage Measurement... 19:39:39 Voltage Offset Correction: v_off_ini = -103.554 uV, v_off_fin = -106.040 uV 19:39:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.619 uVs 19:39:40 Integrated Voltage Measurement... 19:39:48 Voltage Offset Correction: v_off_ini = -98.185 uV, v_off_fin = -102.215 uV 19:39:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.224 uVs 19:39:49 Integrated Voltage Measurement... 19:39:57 Voltage Offset Correction: v_off_ini = -105.691 uV, v_off_fin = -108.242 uV 19:39:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -61.460 uVs 19:39:58 Integrated Voltage Measurement... 19:40:06 Voltage Offset Correction: v_off_ini = -104.469 uV, v_off_fin = -97.757 uV 19:40:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.351 uVs 19:40:07 Integrated Voltage Measurement... 19:40:16 Voltage Offset Correction: v_off_ini = -101.725 uV, v_off_fin = -110.981 uV 19:40:16 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.298 uVs 19:40:16 Integrated Voltage Measurement... 19:40:25 Voltage Offset Correction: v_off_ini = -101.997 uV, v_off_fin = -106.955 uV 19:40:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.305 uVs 19:40:29 I1X Average and RMS of Measurements VT = -58.876 +- 4.635 uVs I1X = 11.775 +- 0.927 uTm 19:40:31 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:40:36 Integrated Voltage Measurement... 19:40:45 Voltage Offset Correction: v_off_ini = -102.319 uV, v_off_fin = -105.157 uV 19:40:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.249 uVs 19:40:45 Integrated Voltage Measurement... 19:40:54 Voltage Offset Correction: v_off_ini = -102.292 uV, v_off_fin = -76.982 uV 19:40:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 237.936 uVs 19:40:54 Integrated Voltage Measurement... 19:41:03 Voltage Offset Correction: v_off_ini = -84.943 uV, v_off_fin = -102.074 uV 19:41:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.795 uVs 19:41:03 Integrated Voltage Measurement... 19:41:11 Voltage Offset Correction: v_off_ini = -98.569 uV, v_off_fin = -82.723 uV 19:41:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.217 uVs 19:41:12 Integrated Voltage Measurement... 19:41:21 Voltage Offset Correction: v_off_ini = -92.822 uV, v_off_fin = -93.581 uV 19:41:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -248.422 uVs 19:41:21 Integrated Voltage Measurement... 19:41:30 Voltage Offset Correction: v_off_ini = -90.756 uV, v_off_fin = -82.321 uV 19:41:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.613 uVs 19:41:34 I1Y Average and RMS of Measurements VT = -236.539 +- 1.400 uVs I1Y = -47.305 +- 0.278 uTm 19:41:36 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:41:39 Integrated Voltage Measurement... 19:41:48 Voltage Offset Correction: v_off_ini = -99.452 uV, v_off_fin = -101.912 uV 19:41:48 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -54.401 uVs 19:41:48 Integrated Voltage Measurement... 19:41:57 Voltage Offset Correction: v_off_ini = -83.863 uV, v_off_fin = -78.303 uV 19:41:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.283 uVs 19:41:57 Integrated Voltage Measurement... 19:42:06 Voltage Offset Correction: v_off_ini = -100.687 uV, v_off_fin = -108.093 uV 19:42:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.241 uVs 19:42:06 Integrated Voltage Measurement... 19:42:15 Voltage Offset Correction: v_off_ini = -92.072 uV, v_off_fin = -94.849 uV 19:42:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.416 uVs 19:42:15 Integrated Voltage Measurement... 19:42:24 Voltage Offset Correction: v_off_ini = -97.451 uV, v_off_fin = -112.271 uV 19:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.530 uVs 19:42:24 Integrated Voltage Measurement... 19:42:33 Voltage Offset Correction: v_off_ini = -101.000 uV, v_off_fin = -87.622 uV 19:42:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.238 uVs 19:42:36 I2X Average and RMS of Measurements VT = -58.018 +- 0.936 uVs I2X = 5.338 +- 0.086 uTm^2 19:42:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 19:42:41 Integrated Voltage Measurement... 19:42:50 Voltage Offset Correction: v_off_ini = -110.002 uV, v_off_fin = -111.657 uV 19:42:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.394 uVs 19:42:50 Integrated Voltage Measurement... 19:42:59 Voltage Offset Correction: v_off_ini = -113.386 uV, v_off_fin = -114.460 uV 19:42:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.883 uVs 19:42:59 Integrated Voltage Measurement... 19:43:08 Voltage Offset Correction: v_off_ini = -115.212 uV, v_off_fin = -109.404 uV 19:43:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -224.313 uVs 19:43:08 Integrated Voltage Measurement... 19:43:17 Voltage Offset Correction: v_off_ini = -101.662 uV, v_off_fin = -104.851 uV 19:43:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.151 uVs 19:43:17 Integrated Voltage Measurement... 19:43:26 Voltage Offset Correction: v_off_ini = -101.792 uV, v_off_fin = -124.903 uV 19:43:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.311 uVs 19:43:26 Integrated Voltage Measurement... 19:43:35 Voltage Offset Correction: v_off_ini = -102.224 uV, v_off_fin = -102.580 uV 19:43:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.527 uVs 19:43:37 I2Y Average and RMS of Measurements VT = -226.930 +- 4.161 uVs I2Y = -20.878 +- 0.383 uTm^2 19:43:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm