SLAC Magnetic Measurements Date: 07-23-2026 Time: 11:52:55 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16336 Dataset Number: 1 Run Purpose: Tuning Run Type: Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 11:53:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:53:56 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:53:58 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:53:59 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:54:01 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 11:55:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:56:00 Integrated Voltage Measurement... 11:56:09 Voltage Offset Correction: v_off_ini = 2180.164 uV, v_off_fin = 2151.829 uV 11:56:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -129.830 uVs 11:56:09 Integrated Voltage Measurement... 11:56:18 Voltage Offset Correction: v_off_ini = 2148.707 uV, v_off_fin = 2161.995 uV 11:56:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.261 uVs 11:56:18 Integrated Voltage Measurement... 11:56:27 Voltage Offset Correction: v_off_ini = 2175.546 uV, v_off_fin = 2160.802 uV 11:56:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.076 uVs 11:56:27 Integrated Voltage Measurement... 11:56:36 Voltage Offset Correction: v_off_ini = 2147.515 uV, v_off_fin = 2191.872 uV 11:56:36 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.413 uVs 11:56:36 Integrated Voltage Measurement... 11:56:45 Voltage Offset Correction: v_off_ini = 2179.415 uV, v_off_fin = 2188.049 uV 11:56:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.454 uVs 11:56:45 Integrated Voltage Measurement... 11:56:54 Voltage Offset Correction: v_off_ini = 2188.310 uV, v_off_fin = 2172.775 uV 11:56:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.068 uVs 11:56:59 I1X Average and RMS of Measurements VT = -134.683 +- 4.298 uVs I1X = 26.937 +- 0.859 uTm 11:57:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:57:05 Integrated Voltage Measurement... 11:57:14 Voltage Offset Correction: v_off_ini = 2154.810 uV, v_off_fin = 2144.468 uV 11:57:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.373 uVs 11:57:14 Integrated Voltage Measurement... 11:57:23 Voltage Offset Correction: v_off_ini = 2147.933 uV, v_off_fin = 2151.110 uV 11:57:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.575 uVs 11:57:23 Integrated Voltage Measurement... 11:57:32 Voltage Offset Correction: v_off_ini = 2140.877 uV, v_off_fin = 2125.583 uV 11:57:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.701 uVs 11:57:32 Integrated Voltage Measurement... 11:57:41 Voltage Offset Correction: v_off_ini = 2104.611 uV, v_off_fin = 2142.148 uV 11:57:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.466 uVs 11:57:41 Integrated Voltage Measurement... 11:57:50 Voltage Offset Correction: v_off_ini = 2139.370 uV, v_off_fin = 2113.515 uV 11:57:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.025 uVs 11:57:50 Integrated Voltage Measurement... 11:57:59 Voltage Offset Correction: v_off_ini = 2101.788 uV, v_off_fin = 2121.588 uV 11:57:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.433 uVs 11:58:03 I1Y Average and RMS of Measurements VT = -246.096 +- 5.057 uVs I1Y = -49.219 +- 1.011 uTm 11:58:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:58:11 Integrated Voltage Measurement... 11:58:20 Voltage Offset Correction: v_off_ini = 2093.182 uV, v_off_fin = 2087.526 uV 11:58:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -149.321 uVs 11:58:20 Integrated Voltage Measurement... 11:58:29 Voltage Offset Correction: v_off_ini = 2095.947 uV, v_off_fin = 2111.491 uV 11:58:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 148.122 uVs 11:58:29 Integrated Voltage Measurement... 11:58:38 Voltage Offset Correction: v_off_ini = 2116.799 uV, v_off_fin = 2082.491 uV 11:58:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -172.470 uVs 11:58:38 Integrated Voltage Measurement... 11:58:47 Voltage Offset Correction: v_off_ini = 2088.420 uV, v_off_fin = 2097.951 uV 11:58:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 131.691 uVs 11:58:47 Integrated Voltage Measurement... 11:58:56 Voltage Offset Correction: v_off_ini = 2085.690 uV, v_off_fin = 2112.283 uV 11:58:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -154.446 uVs 11:58:56 Integrated Voltage Measurement... 11:59:05 Voltage Offset Correction: v_off_ini = 2105.847 uV, v_off_fin = 2117.264 uV 11:59:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 109.627 uVs 11:59:07 I2X Average and RMS of Measurements VT = -144.280 +- 8.765 uVs I2X = 13.274 +- 0.806 uTm^2 11:59:13 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:59:15 Integrated Voltage Measurement... 11:59:24 Voltage Offset Correction: v_off_ini = 2102.242 uV, v_off_fin = 2083.791 uV 11:59:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -376.303 uVs 11:59:24 Integrated Voltage Measurement... 11:59:33 Voltage Offset Correction: v_off_ini = 2106.152 uV, v_off_fin = 2087.530 uV 11:59:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 432.535 uVs 11:59:33 Integrated Voltage Measurement... 11:59:42 Voltage Offset Correction: v_off_ini = 2101.476 uV, v_off_fin = 2100.415 uV 11:59:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -387.900 uVs 11:59:42 Integrated Voltage Measurement... 11:59:51 Voltage Offset Correction: v_off_ini = 2074.237 uV, v_off_fin = 2093.201 uV 11:59:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 415.480 uVs 11:59:51 Integrated Voltage Measurement... 12:00:00 Voltage Offset Correction: v_off_ini = 2087.284 uV, v_off_fin = 2088.155 uV 12:00:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -408.749 uVs 12:00:00 Integrated Voltage Measurement... 12:00:09 Voltage Offset Correction: v_off_ini = 2097.185 uV, v_off_fin = 2091.242 uV 12:00:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 391.248 uVs 12:00:12 I2Y Average and RMS of Measurements VT = -402.036 +- 1.821 uVs I2Y = -36.987 +- 0.168 uTm^2 12:00:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:00:27 Integrated Voltage Measurement... 12:00:36 Voltage Offset Correction: v_off_ini = 2113.569 uV, v_off_fin = 2101.817 uV 12:00:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.073 uVs 12:00:36 Integrated Voltage Measurement... 12:00:45 Voltage Offset Correction: v_off_ini = 2121.214 uV, v_off_fin = 2142.817 uV 12:00:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.720 uVs 12:00:45 Integrated Voltage Measurement... 12:00:54 Voltage Offset Correction: v_off_ini = 2129.412 uV, v_off_fin = 2130.742 uV 12:00:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.876 uVs 12:00:54 Integrated Voltage Measurement... 12:01:03 Voltage Offset Correction: v_off_ini = 2129.422 uV, v_off_fin = 2129.450 uV 12:01:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.278 uVs 12:01:03 Integrated Voltage Measurement... 12:01:12 Voltage Offset Correction: v_off_ini = 2125.539 uV, v_off_fin = 2134.147 uV 12:01:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.836 uVs 12:01:12 Integrated Voltage Measurement... 12:01:21 Voltage Offset Correction: v_off_ini = 2134.589 uV, v_off_fin = 2123.510 uV 12:01:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.356 uVs 12:01:25 I1X Average and RMS of Measurements VT = -129.523 +- 5.589 uVs I1X = 25.905 +- 1.118 uTm 12:01:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:32 Integrated Voltage Measurement... 12:01:41 Voltage Offset Correction: v_off_ini = 2118.305 uV, v_off_fin = 2102.032 uV 12:01:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.162 uVs 12:01:41 Integrated Voltage Measurement... 12:01:49 Voltage Offset Correction: v_off_ini = 2165.041 uV, v_off_fin = 2187.913 uV 12:01:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.694 uVs 12:01:50 Integrated Voltage Measurement... 12:01:58 Voltage Offset Correction: v_off_ini = 2157.250 uV, v_off_fin = 2134.457 uV 12:01:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.475 uVs 12:01:59 Integrated Voltage Measurement... 12:02:07 Voltage Offset Correction: v_off_ini = 2115.608 uV, v_off_fin = 2142.445 uV 12:02:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.080 uVs 12:02:08 Integrated Voltage Measurement... 12:02:16 Voltage Offset Correction: v_off_ini = 2141.991 uV, v_off_fin = 2115.231 uV 12:02:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.552 uVs 12:02:16 Integrated Voltage Measurement... 12:02:25 Voltage Offset Correction: v_off_ini = 2099.938 uV, v_off_fin = 2112.999 uV 12:02:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.919 uVs 12:02:30 I1Y Average and RMS of Measurements VT = -233.814 +- 9.767 uVs I1Y = -46.763 +- 1.953 uTm 12:02:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:02:37 Integrated Voltage Measurement... 12:02:46 Voltage Offset Correction: v_off_ini = 2115.343 uV, v_off_fin = 2107.434 uV 12:02:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -152.846 uVs 12:02:46 Integrated Voltage Measurement... 12:02:55 Voltage Offset Correction: v_off_ini = 2095.330 uV, v_off_fin = 2126.292 uV 12:02:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 137.244 uVs 12:02:55 Integrated Voltage Measurement... 12:03:04 Voltage Offset Correction: v_off_ini = 2109.728 uV, v_off_fin = 2100.302 uV 12:03:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -143.471 uVs 12:03:04 Integrated Voltage Measurement... 12:03:13 Voltage Offset Correction: v_off_ini = 2120.950 uV, v_off_fin = 2135.852 uV 12:03:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.434 uVs 12:03:13 Integrated Voltage Measurement... 12:03:22 Voltage Offset Correction: v_off_ini = 2126.792 uV, v_off_fin = 2113.070 uV 12:03:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -167.366 uVs 12:03:22 Integrated Voltage Measurement... 12:03:31 Voltage Offset Correction: v_off_ini = 2111.254 uV, v_off_fin = 2134.855 uV 12:03:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 133.113 uVs 12:03:34 I2X Average and RMS of Measurements VT = -146.246 +- 2.898 uVs I2X = 13.455 +- 0.267 uTm^2 12:03:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:03:42 Integrated Voltage Measurement... 12:03:50 Voltage Offset Correction: v_off_ini = 2127.808 uV, v_off_fin = 2128.900 uV 12:03:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -355.445 uVs 12:03:51 Integrated Voltage Measurement... 12:03:59 Voltage Offset Correction: v_off_ini = 2114.228 uV, v_off_fin = 2123.281 uV 12:04:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 369.457 uVs 12:04:00 Integrated Voltage Measurement... 12:04:09 Voltage Offset Correction: v_off_ini = 2110.450 uV, v_off_fin = 2143.820 uV 12:04:09 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -387.926 uVs 12:04:09 Integrated Voltage Measurement... 12:04:18 Voltage Offset Correction: v_off_ini = 2131.102 uV, v_off_fin = 2155.226 uV 12:04:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 378.177 uVs 12:04:18 Integrated Voltage Measurement... 12:04:27 Voltage Offset Correction: v_off_ini = 2196.969 uV, v_off_fin = 2178.870 uV 12:04:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -372.061 uVs 12:04:27 Integrated Voltage Measurement... 12:04:36 Voltage Offset Correction: v_off_ini = 2178.484 uV, v_off_fin = 2175.296 uV 12:04:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 356.363 uVs 12:04:38 I2Y Average and RMS of Measurements VT = -369.905 +- 9.324 uVs I2Y = -34.032 +- 0.859 uTm^2 12:04:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:04:53 Integrated Voltage Measurement... 12:05:02 Voltage Offset Correction: v_off_ini = 2181.282 uV, v_off_fin = 2166.391 uV 12:05:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.715 uVs 12:05:02 Integrated Voltage Measurement... 12:05:11 Voltage Offset Correction: v_off_ini = 2158.378 uV, v_off_fin = 2165.282 uV 12:05:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.567 uVs 12:05:11 Integrated Voltage Measurement... 12:05:20 Voltage Offset Correction: v_off_ini = 2154.019 uV, v_off_fin = 2160.018 uV 12:05:20 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.589 uVs 12:05:20 Integrated Voltage Measurement... 12:05:29 Voltage Offset Correction: v_off_ini = 2177.806 uV, v_off_fin = 2164.770 uV 12:05:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.946 uVs 12:05:29 Integrated Voltage Measurement... 12:05:38 Voltage Offset Correction: v_off_ini = 2157.703 uV, v_off_fin = 2158.910 uV 12:05:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.962 uVs 12:05:38 Integrated Voltage Measurement... 12:05:47 Voltage Offset Correction: v_off_ini = 2156.738 uV, v_off_fin = 2164.993 uV 12:05:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.482 uVs 12:05:51 I1X Average and RMS of Measurements VT = -136.710 +- 3.223 uVs I1X = 27.343 +- 0.645 uTm 12:05:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:05:58 Integrated Voltage Measurement... 12:06:07 Voltage Offset Correction: v_off_ini = 2183.129 uV, v_off_fin = 2173.394 uV 12:06:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -240.827 uVs 12:06:07 Integrated Voltage Measurement... 12:06:16 Voltage Offset Correction: v_off_ini = 2177.648 uV, v_off_fin = 2167.614 uV 12:06:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.800 uVs 12:06:16 Integrated Voltage Measurement... 12:06:25 Voltage Offset Correction: v_off_ini = 2162.271 uV, v_off_fin = 2145.885 uV 12:06:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.373 uVs 12:06:25 Integrated Voltage Measurement... 12:06:34 Voltage Offset Correction: v_off_ini = 2133.858 uV, v_off_fin = 2164.516 uV 12:06:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.161 uVs 12:06:34 Integrated Voltage Measurement... 12:06:43 Voltage Offset Correction: v_off_ini = 2163.189 uV, v_off_fin = 2144.921 uV 12:06:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.122 uVs 12:06:43 Integrated Voltage Measurement... 12:06:52 Voltage Offset Correction: v_off_ini = 2163.770 uV, v_off_fin = 2156.062 uV 12:06:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.012 uVs 12:06:56 I1Y Average and RMS of Measurements VT = -209.883 +- 9.279 uVs I1Y = -41.977 +- 1.856 uTm 12:07:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:04 Integrated Voltage Measurement... 12:07:13 Voltage Offset Correction: v_off_ini = 2131.749 uV, v_off_fin = 2143.543 uV 12:07:13 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -168.920 uVs 12:07:13 Integrated Voltage Measurement... 12:07:22 Voltage Offset Correction: v_off_ini = 2124.216 uV, v_off_fin = 2117.340 uV 12:07:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.531 uVs 12:07:22 Integrated Voltage Measurement... 12:07:31 Voltage Offset Correction: v_off_ini = 2124.590 uV, v_off_fin = 2111.943 uV 12:07:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -167.468 uVs 12:07:31 Integrated Voltage Measurement... 12:07:40 Voltage Offset Correction: v_off_ini = 2151.475 uV, v_off_fin = 2155.314 uV 12:07:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.215 uVs 12:07:40 Integrated Voltage Measurement... 12:07:49 Voltage Offset Correction: v_off_ini = 2160.941 uV, v_off_fin = 2137.630 uV 12:07:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -141.190 uVs 12:07:49 Integrated Voltage Measurement... 12:07:58 Voltage Offset Correction: v_off_ini = 2134.188 uV, v_off_fin = 2148.271 uV 12:07:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.533 uVs 12:08:00 I2X Average and RMS of Measurements VT = -147.309 +- 13.445 uVs I2X = 13.552 +- 1.236 uTm^2 12:08:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:08:08 Integrated Voltage Measurement... 12:08:17 Voltage Offset Correction: v_off_ini = 2135.901 uV, v_off_fin = 2107.214 uV 12:08:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.464 uVs 12:08:17 Integrated Voltage Measurement... 12:08:26 Voltage Offset Correction: v_off_ini = 2135.131 uV, v_off_fin = 2126.745 uV 12:08:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 372.187 uVs 12:08:26 Integrated Voltage Measurement... 12:08:35 Voltage Offset Correction: v_off_ini = 2116.762 uV, v_off_fin = 2136.069 uV 12:08:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -371.962 uVs 12:08:35 Integrated Voltage Measurement... 12:08:44 Voltage Offset Correction: v_off_ini = 2148.803 uV, v_off_fin = 2150.499 uV 12:08:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.663 uVs 12:08:44 Integrated Voltage Measurement... 12:08:53 Voltage Offset Correction: v_off_ini = 2127.560 uV, v_off_fin = 2144.186 uV 12:08:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.754 uVs 12:08:53 Integrated Voltage Measurement... 12:09:02 Voltage Offset Correction: v_off_ini = 2139.564 uV, v_off_fin = 2141.373 uV 12:09:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.664 uVs 12:09:04 I2Y Average and RMS of Measurements VT = -345.949 +- 13.868 uVs I2Y = -31.827 +- 1.276 uTm^2 12:09:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:19 Integrated Voltage Measurement... 12:09:28 Voltage Offset Correction: v_off_ini = 2130.694 uV, v_off_fin = 2129.499 uV 12:09:28 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.625 uVs 12:09:28 Integrated Voltage Measurement... 12:09:37 Voltage Offset Correction: v_off_ini = 2132.473 uV, v_off_fin = 2160.708 uV 12:09:37 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 135.798 uVs 12:09:37 Integrated Voltage Measurement... 12:09:46 Voltage Offset Correction: v_off_ini = 2115.490 uV, v_off_fin = 2150.330 uV 12:09:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.929 uVs 12:09:46 Integrated Voltage Measurement... 12:09:55 Voltage Offset Correction: v_off_ini = 2182.262 uV, v_off_fin = 2158.999 uV 12:09:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.551 uVs 12:09:55 Integrated Voltage Measurement... 12:10:04 Voltage Offset Correction: v_off_ini = 2166.504 uV, v_off_fin = 2157.910 uV 12:10:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.257 uVs 12:10:04 Integrated Voltage Measurement... 12:10:13 Voltage Offset Correction: v_off_ini = 2142.522 uV, v_off_fin = 2152.059 uV 12:10:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.069 uVs 12:10:18 I1X Average and RMS of Measurements VT = -118.371 +- 11.933 uVs I1X = 23.676 +- 2.387 uTm 12:10:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:10:24 Integrated Voltage Measurement... 12:10:33 Voltage Offset Correction: v_off_ini = 2158.589 uV, v_off_fin = 2147.773 uV 12:10:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -191.343 uVs 12:10:33 Integrated Voltage Measurement... 12:10:42 Voltage Offset Correction: v_off_ini = 2173.973 uV, v_off_fin = 2178.288 uV 12:10:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.918 uVs 12:10:42 Integrated Voltage Measurement... 12:10:51 Voltage Offset Correction: v_off_ini = 2193.310 uV, v_off_fin = 2180.718 uV 12:10:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.780 uVs 12:10:51 Integrated Voltage Measurement... 12:11:00 Voltage Offset Correction: v_off_ini = 2160.984 uV, v_off_fin = 2191.769 uV 12:11:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.631 uVs 12:11:00 Integrated Voltage Measurement... 12:11:09 Voltage Offset Correction: v_off_ini = 2196.015 uV, v_off_fin = 2175.153 uV 12:11:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.870 uVs 12:11:09 Integrated Voltage Measurement... 12:11:18 Voltage Offset Correction: v_off_ini = 2156.979 uV, v_off_fin = 2168.035 uV 12:11:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.736 uVs 12:11:23 I1Y Average and RMS of Measurements VT = -210.213 +- 2.294 uVs I1Y = -42.043 +- 0.458 uTm 12:11:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:11:30 Integrated Voltage Measurement... 12:11:39 Voltage Offset Correction: v_off_ini = 2162.165 uV, v_off_fin = 2138.581 uV 12:11:39 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -161.364 uVs 12:11:39 Integrated Voltage Measurement... 12:11:48 Voltage Offset Correction: v_off_ini = 2107.259 uV, v_off_fin = 2154.630 uV 12:11:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.057 uVs 12:11:48 Integrated Voltage Measurement... 12:11:57 Voltage Offset Correction: v_off_ini = 2154.907 uV, v_off_fin = 2134.954 uV 12:11:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.692 uVs 12:11:57 Integrated Voltage Measurement... 12:12:06 Voltage Offset Correction: v_off_ini = 2165.798 uV, v_off_fin = 2176.572 uV 12:12:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 167.681 uVs 12:12:06 Integrated Voltage Measurement... 12:12:15 Voltage Offset Correction: v_off_ini = 2147.661 uV, v_off_fin = 2138.693 uV 12:12:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -174.457 uVs 12:12:15 Integrated Voltage Measurement... 12:12:24 Voltage Offset Correction: v_off_ini = 2155.956 uV, v_off_fin = 2153.250 uV 12:12:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.362 uVs 12:12:27 I2X Average and RMS of Measurements VT = -153.102 +- 6.228 uVs I2X = 14.085 +- 0.573 uTm^2 12:12:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:12:35 Integrated Voltage Measurement... 12:12:43 Voltage Offset Correction: v_off_ini = 2197.030 uV, v_off_fin = 2177.223 uV 12:12:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.308 uVs 12:12:44 Integrated Voltage Measurement... 12:12:53 Voltage Offset Correction: v_off_ini = 2192.769 uV, v_off_fin = 2199.233 uV 12:12:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.369 uVs 12:12:53 Integrated Voltage Measurement... 12:13:02 Voltage Offset Correction: v_off_ini = 2174.426 uV, v_off_fin = 2174.508 uV 12:13:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.615 uVs 12:13:02 Integrated Voltage Measurement... 12:13:11 Voltage Offset Correction: v_off_ini = 2184.533 uV, v_off_fin = 2165.376 uV 12:13:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.490 uVs 12:13:11 Integrated Voltage Measurement... 12:13:20 Voltage Offset Correction: v_off_ini = 2145.509 uV, v_off_fin = 2153.044 uV 12:13:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.115 uVs 12:13:20 Integrated Voltage Measurement... 12:13:29 Voltage Offset Correction: v_off_ini = 2156.944 uV, v_off_fin = 2163.247 uV 12:13:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 355.687 uVs 12:13:31 I2Y Average and RMS of Measurements VT = -338.597 +- 5.417 uVs I2Y = -31.151 +- 0.498 uTm^2 12:13:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:13:46 Integrated Voltage Measurement... 12:13:55 Voltage Offset Correction: v_off_ini = 2180.558 uV, v_off_fin = 2171.523 uV 12:13:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -179.591 uVs 12:13:55 Integrated Voltage Measurement... 12:14:04 Voltage Offset Correction: v_off_ini = 2178.082 uV, v_off_fin = 2185.991 uV 12:14:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 170.440 uVs 12:14:04 Integrated Voltage Measurement... 12:14:13 Voltage Offset Correction: v_off_ini = 2170.547 uV, v_off_fin = 2194.448 uV 12:14:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.479 uVs 12:14:13 Integrated Voltage Measurement... 12:14:22 Voltage Offset Correction: v_off_ini = 2189.330 uV, v_off_fin = 2201.580 uV 12:14:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.655 uVs 12:14:22 Integrated Voltage Measurement... 12:14:31 Voltage Offset Correction: v_off_ini = 2202.663 uV, v_off_fin = 2195.037 uV 12:14:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -153.414 uVs 12:14:31 Integrated Voltage Measurement... 12:14:40 Voltage Offset Correction: v_off_ini = 2193.041 uV, v_off_fin = 2198.761 uV 12:14:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.211 uVs 12:14:44 I1X Average and RMS of Measurements VT = -140.632 +- 26.026 uVs I1X = 28.127 +- 5.206 uTm 12:14:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:14:51 Integrated Voltage Measurement... 12:15:00 Voltage Offset Correction: v_off_ini = 2196.044 uV, v_off_fin = 2173.298 uV 12:15:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.082 uVs 12:15:00 Integrated Voltage Measurement... 12:15:09 Voltage Offset Correction: v_off_ini = 2173.130 uV, v_off_fin = 2188.285 uV 12:15:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.088 uVs 12:15:09 Integrated Voltage Measurement... 12:15:18 Voltage Offset Correction: v_off_ini = 2167.333 uV, v_off_fin = 2173.898 uV 12:15:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.864 uVs 12:15:18 Integrated Voltage Measurement... 12:15:27 Voltage Offset Correction: v_off_ini = 2153.588 uV, v_off_fin = 2178.677 uV 12:15:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.997 uVs 12:15:27 Integrated Voltage Measurement... 12:15:36 Voltage Offset Correction: v_off_ini = 2164.320 uV, v_off_fin = 2166.773 uV 12:15:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.004 uVs 12:15:36 Integrated Voltage Measurement... 12:15:45 Voltage Offset Correction: v_off_ini = 2181.119 uV, v_off_fin = 2179.312 uV 12:15:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.675 uVs 12:15:49 I1Y Average and RMS of Measurements VT = -191.118 +- 4.269 uVs I1Y = -38.224 +- 0.854 uTm 12:15:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:15:57 Integrated Voltage Measurement... 12:16:06 Voltage Offset Correction: v_off_ini = 2176.942 uV, v_off_fin = 2163.307 uV 12:16:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -168.804 uVs 12:16:06 Integrated Voltage Measurement... 12:16:15 Voltage Offset Correction: v_off_ini = 2152.563 uV, v_off_fin = 2192.389 uV 12:16:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 148.813 uVs 12:16:15 Integrated Voltage Measurement... 12:16:24 Voltage Offset Correction: v_off_ini = 2180.502 uV, v_off_fin = 2192.285 uV 12:16:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -155.692 uVs 12:16:24 Integrated Voltage Measurement... 12:16:33 Voltage Offset Correction: v_off_ini = 2182.495 uV, v_off_fin = 2197.844 uV 12:16:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.891 uVs 12:16:33 Integrated Voltage Measurement... 12:16:42 Voltage Offset Correction: v_off_ini = 2119.853 uV, v_off_fin = 2175.995 uV 12:16:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.439 uVs 12:16:42 Integrated Voltage Measurement... 12:16:51 Voltage Offset Correction: v_off_ini = 2182.024 uV, v_off_fin = 2206.716 uV 12:16:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 163.399 uVs 12:16:53 I2X Average and RMS of Measurements VT = -144.840 +- 17.327 uVs I2X = 13.326 +- 1.594 uTm^2 12:16:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:17:01 Integrated Voltage Measurement... 12:17:10 Voltage Offset Correction: v_off_ini = 2186.940 uV, v_off_fin = 2178.957 uV 12:17:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -331.527 uVs 12:17:10 Integrated Voltage Measurement... 12:17:19 Voltage Offset Correction: v_off_ini = 2173.605 uV, v_off_fin = 2163.246 uV 12:17:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 316.777 uVs 12:17:19 Integrated Voltage Measurement... 12:17:28 Voltage Offset Correction: v_off_ini = 2166.660 uV, v_off_fin = 2197.188 uV 12:17:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.269 uVs 12:17:28 Integrated Voltage Measurement... 12:17:37 Voltage Offset Correction: v_off_ini = 2206.141 uV, v_off_fin = 2229.093 uV 12:17:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.608 uVs 12:17:37 Integrated Voltage Measurement... 12:17:46 Voltage Offset Correction: v_off_ini = 2257.477 uV, v_off_fin = 2254.714 uV 12:17:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.193 uVs 12:17:46 Integrated Voltage Measurement... 12:17:55 Voltage Offset Correction: v_off_ini = 2237.465 uV, v_off_fin = 2227.622 uV 12:17:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.316 uVs 12:17:58 I2Y Average and RMS of Measurements VT = -312.949 +- 8.598 uVs I2Y = -28.791 +- 0.791 uTm^2 12:18:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:18:13 Integrated Voltage Measurement... 12:18:22 Voltage Offset Correction: v_off_ini = 2216.065 uV, v_off_fin = 2203.780 uV 12:18:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -176.400 uVs 12:18:22 Integrated Voltage Measurement... 12:18:31 Voltage Offset Correction: v_off_ini = 2228.870 uV, v_off_fin = 2217.267 uV 12:18:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.537 uVs 12:18:31 Integrated Voltage Measurement... 12:18:40 Voltage Offset Correction: v_off_ini = 2212.881 uV, v_off_fin = 2209.568 uV 12:18:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.579 uVs 12:18:40 Integrated Voltage Measurement... 12:18:49 Voltage Offset Correction: v_off_ini = 2228.659 uV, v_off_fin = 2238.485 uV 12:18:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 176.966 uVs 12:18:49 Integrated Voltage Measurement... 12:18:58 Voltage Offset Correction: v_off_ini = 2236.811 uV, v_off_fin = 2217.161 uV 12:18:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.733 uVs 12:18:58 Integrated Voltage Measurement... 12:19:07 Voltage Offset Correction: v_off_ini = 2240.886 uV, v_off_fin = 2217.453 uV 12:19:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 166.607 uVs 12:19:11 I1X Average and RMS of Measurements VT = -152.304 +- 4.831 uVs I1X = 30.461 +- 0.966 uTm 12:19:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:19:18 Integrated Voltage Measurement... 12:19:27 Voltage Offset Correction: v_off_ini = 2207.288 uV, v_off_fin = 2207.290 uV 12:19:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -183.861 uVs 12:19:27 Integrated Voltage Measurement... 12:19:36 Voltage Offset Correction: v_off_ini = 2228.518 uV, v_off_fin = 2226.782 uV 12:19:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.084 uVs 12:19:36 Integrated Voltage Measurement... 12:19:45 Voltage Offset Correction: v_off_ini = 2225.787 uV, v_off_fin = 2192.088 uV 12:19:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -158.285 uVs 12:19:45 Integrated Voltage Measurement... 12:19:54 Voltage Offset Correction: v_off_ini = 2216.183 uV, v_off_fin = 2224.381 uV 12:19:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.532 uVs 12:19:54 Integrated Voltage Measurement... 12:20:03 Voltage Offset Correction: v_off_ini = 2229.484 uV, v_off_fin = 2216.417 uV 12:20:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.314 uVs 12:20:03 Integrated Voltage Measurement... 12:20:12 Voltage Offset Correction: v_off_ini = 2242.968 uV, v_off_fin = 2233.321 uV 12:20:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.122 uVs 12:20:16 I1Y Average and RMS of Measurements VT = -188.367 +- 7.487 uVs I1Y = -37.674 +- 1.497 uTm 12:20:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:20:24 Integrated Voltage Measurement... 12:20:33 Voltage Offset Correction: v_off_ini = 2258.166 uV, v_off_fin = 2259.109 uV 12:20:33 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -138.912 uVs 12:20:33 Integrated Voltage Measurement... 12:20:42 Voltage Offset Correction: v_off_ini = 2243.750 uV, v_off_fin = 2260.644 uV 12:20:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 158.633 uVs 12:20:42 Integrated Voltage Measurement... 12:20:51 Voltage Offset Correction: v_off_ini = 2241.112 uV, v_off_fin = 2264.060 uV 12:20:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -159.933 uVs 12:20:51 Integrated Voltage Measurement... 12:21:00 Voltage Offset Correction: v_off_ini = 2286.579 uV, v_off_fin = 2273.927 uV 12:21:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.488 uVs 12:21:00 Integrated Voltage Measurement... 12:21:09 Voltage Offset Correction: v_off_ini = 2242.164 uV, v_off_fin = 2241.303 uV 12:21:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -166.723 uVs 12:21:09 Integrated Voltage Measurement... 12:21:18 Voltage Offset Correction: v_off_ini = 2287.027 uV, v_off_fin = 2249.761 uV 12:21:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 114.424 uVs 12:21:20 I2X Average and RMS of Measurements VT = -147.685 +- 5.418 uVs I2X = 13.587 +- 0.498 uTm^2 12:21:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:21:28 Integrated Voltage Measurement... 12:21:37 Voltage Offset Correction: v_off_ini = 2238.303 uV, v_off_fin = 2244.069 uV 12:21:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.460 uVs 12:21:37 Integrated Voltage Measurement... 12:21:46 Voltage Offset Correction: v_off_ini = 2254.100 uV, v_off_fin = 2259.602 uV 12:21:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.511 uVs 12:21:46 Integrated Voltage Measurement... 12:21:55 Voltage Offset Correction: v_off_ini = 2269.982 uV, v_off_fin = 2243.590 uV 12:21:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.937 uVs 12:21:55 Integrated Voltage Measurement... 12:22:04 Voltage Offset Correction: v_off_ini = 2232.373 uV, v_off_fin = 2225.581 uV 12:22:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.536 uVs 12:22:04 Integrated Voltage Measurement... 12:22:13 Voltage Offset Correction: v_off_ini = 2225.964 uV, v_off_fin = 2209.913 uV 12:22:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.108 uVs 12:22:13 Integrated Voltage Measurement... 12:22:22 Voltage Offset Correction: v_off_ini = 2221.767 uV, v_off_fin = 2203.397 uV 12:22:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.895 uVs 12:22:24 I2Y Average and RMS of Measurements VT = -315.408 +- 8.143 uVs I2Y = -29.018 +- 0.749 uTm^2 12:22:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:22:39 Integrated Voltage Measurement... 12:22:48 Voltage Offset Correction: v_off_ini = 2207.703 uV, v_off_fin = 2185.168 uV 12:22:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.916 uVs 12:22:48 Integrated Voltage Measurement... 12:22:57 Voltage Offset Correction: v_off_ini = 2209.543 uV, v_off_fin = 2232.814 uV 12:22:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.554 uVs 12:22:57 Integrated Voltage Measurement... 12:23:06 Voltage Offset Correction: v_off_ini = 2233.461 uV, v_off_fin = 2236.514 uV 12:23:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.584 uVs 12:23:06 Integrated Voltage Measurement... 12:23:15 Voltage Offset Correction: v_off_ini = 2247.296 uV, v_off_fin = 2242.243 uV 12:23:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 167.005 uVs 12:23:16 Integrated Voltage Measurement... 12:23:24 Voltage Offset Correction: v_off_ini = 2239.483 uV, v_off_fin = 2260.262 uV 12:23:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.627 uVs 12:23:25 Integrated Voltage Measurement... 12:23:33 Voltage Offset Correction: v_off_ini = 2301.251 uV, v_off_fin = 2266.694 uV 12:23:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 177.432 uVs 12:23:38 I1X Average and RMS of Measurements VT = -142.020 +- 9.618 uVs I1X = 28.404 +- 1.924 uTm 12:23:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:23:44 Integrated Voltage Measurement... 12:23:53 Voltage Offset Correction: v_off_ini = 2278.251 uV, v_off_fin = 2255.989 uV 12:23:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -179.613 uVs 12:23:53 Integrated Voltage Measurement... 12:24:02 Voltage Offset Correction: v_off_ini = 2258.345 uV, v_off_fin = 2297.456 uV 12:24:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.589 uVs 12:24:02 Integrated Voltage Measurement... 12:24:11 Voltage Offset Correction: v_off_ini = 2285.919 uV, v_off_fin = 2270.707 uV 12:24:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.319 uVs 12:24:11 Integrated Voltage Measurement... 12:24:20 Voltage Offset Correction: v_off_ini = 2287.797 uV, v_off_fin = 2294.677 uV 12:24:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.865 uVs 12:24:20 Integrated Voltage Measurement... 12:24:29 Voltage Offset Correction: v_off_ini = 2280.692 uV, v_off_fin = 2275.913 uV 12:24:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.567 uVs 12:24:29 Integrated Voltage Measurement... 12:24:38 Voltage Offset Correction: v_off_ini = 2290.433 uV, v_off_fin = 2317.709 uV 12:24:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.250 uVs 12:24:43 I1Y Average and RMS of Measurements VT = -190.200 +- 5.433 uVs I1Y = -38.041 +- 1.086 uTm 12:24:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:24:50 Integrated Voltage Measurement... 12:24:59 Voltage Offset Correction: v_off_ini = 2254.445 uV, v_off_fin = 2263.525 uV 12:24:59 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -129.604 uVs 12:24:59 Integrated Voltage Measurement... 12:25:08 Voltage Offset Correction: v_off_ini = 2276.443 uV, v_off_fin = 2298.772 uV 12:25:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.035 uVs 12:25:08 Integrated Voltage Measurement... 12:25:17 Voltage Offset Correction: v_off_ini = 2278.697 uV, v_off_fin = 2283.314 uV 12:25:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -189.091 uVs 12:25:17 Integrated Voltage Measurement... 12:25:26 Voltage Offset Correction: v_off_ini = 2291.102 uV, v_off_fin = 2290.407 uV 12:25:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 154.100 uVs 12:25:26 Integrated Voltage Measurement... 12:25:35 Voltage Offset Correction: v_off_ini = 2308.325 uV, v_off_fin = 2291.025 uV 12:25:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.532 uVs 12:25:35 Integrated Voltage Measurement... 12:25:44 Voltage Offset Correction: v_off_ini = 2313.145 uV, v_off_fin = 2325.895 uV 12:25:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.135 uVs 12:25:47 I2X Average and RMS of Measurements VT = -148.749 +- 16.159 uVs I2X = 13.685 +- 1.487 uTm^2 12:25:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:25:54 Integrated Voltage Measurement... 12:26:03 Voltage Offset Correction: v_off_ini = 2332.049 uV, v_off_fin = 2312.500 uV 12:26:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.707 uVs 12:26:04 Integrated Voltage Measurement... 12:26:12 Voltage Offset Correction: v_off_ini = 2323.133 uV, v_off_fin = 2320.123 uV 12:26:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.402 uVs 12:26:13 Integrated Voltage Measurement... 12:26:22 Voltage Offset Correction: v_off_ini = 2323.553 uV, v_off_fin = 2300.282 uV 12:26:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.487 uVs 12:26:22 Integrated Voltage Measurement... 12:26:31 Voltage Offset Correction: v_off_ini = 2303.041 uV, v_off_fin = 2303.549 uV 12:26:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.864 uVs 12:26:31 Integrated Voltage Measurement... 12:26:40 Voltage Offset Correction: v_off_ini = 2294.425 uV, v_off_fin = 2304.272 uV 12:26:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.496 uVs 12:26:40 Integrated Voltage Measurement... 12:26:49 Voltage Offset Correction: v_off_ini = 2295.030 uV, v_off_fin = 2286.041 uV 12:26:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.768 uVs 12:26:51 I2Y Average and RMS of Measurements VT = -291.121 +- 1.512 uVs I2Y = -26.783 +- 0.139 uTm^2 12:27:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:27:06 Integrated Voltage Measurement... 12:27:15 Voltage Offset Correction: v_off_ini = 2293.352 uV, v_off_fin = 2278.484 uV 12:27:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.630 uVs 12:27:15 Integrated Voltage Measurement... 12:27:24 Voltage Offset Correction: v_off_ini = 2290.563 uV, v_off_fin = 2302.884 uV 12:27:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.393 uVs 12:27:24 Integrated Voltage Measurement... 12:27:33 Voltage Offset Correction: v_off_ini = 2295.963 uV, v_off_fin = 2300.924 uV 12:27:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.534 uVs 12:27:33 Integrated Voltage Measurement... 12:27:42 Voltage Offset Correction: v_off_ini = 2314.232 uV, v_off_fin = 2297.506 uV 12:27:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.977 uVs 12:27:42 Integrated Voltage Measurement... 12:27:51 Voltage Offset Correction: v_off_ini = 2310.826 uV, v_off_fin = 2311.001 uV 12:27:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -163.051 uVs 12:27:51 Integrated Voltage Measurement... 12:28:00 Voltage Offset Correction: v_off_ini = 2300.430 uV, v_off_fin = 2283.090 uV 12:28:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.412 uVs 12:28:04 I1X Average and RMS of Measurements VT = -147.833 +- 9.946 uVs I1X = 29.567 +- 1.989 uTm 12:28:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:11 Integrated Voltage Measurement... 12:28:20 Voltage Offset Correction: v_off_ini = 2290.938 uV, v_off_fin = 2272.295 uV 12:28:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -167.038 uVs 12:28:20 Integrated Voltage Measurement... 12:28:29 Voltage Offset Correction: v_off_ini = 2282.371 uV, v_off_fin = 2296.427 uV 12:28:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 156.827 uVs 12:28:29 Integrated Voltage Measurement... 12:28:38 Voltage Offset Correction: v_off_ini = 2284.621 uV, v_off_fin = 2271.795 uV 12:28:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -169.010 uVs 12:28:38 Integrated Voltage Measurement... 12:28:47 Voltage Offset Correction: v_off_ini = 2287.811 uV, v_off_fin = 2296.344 uV 12:28:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.903 uVs 12:28:47 Integrated Voltage Measurement... 12:28:56 Voltage Offset Correction: v_off_ini = 2286.230 uV, v_off_fin = 2275.508 uV 12:28:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -178.377 uVs 12:28:56 Integrated Voltage Measurement... 12:29:05 Voltage Offset Correction: v_off_ini = 2310.353 uV, v_off_fin = 2304.602 uV 12:29:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 181.914 uVs 12:29:09 I1Y Average and RMS of Measurements VT = -171.845 +- 7.522 uVs I1Y = -34.370 +- 1.504 uTm 12:29:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:17 Integrated Voltage Measurement... 12:29:26 Voltage Offset Correction: v_off_ini = 2293.453 uV, v_off_fin = 2305.345 uV 12:29:26 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -153.488 uVs 12:29:26 Integrated Voltage Measurement... 12:29:35 Voltage Offset Correction: v_off_ini = 2312.199 uV, v_off_fin = 2330.096 uV 12:29:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.511 uVs 12:29:35 Integrated Voltage Measurement... 12:29:44 Voltage Offset Correction: v_off_ini = 2313.900 uV, v_off_fin = 2285.239 uV 12:29:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.546 uVs 12:29:44 Integrated Voltage Measurement... 12:29:53 Voltage Offset Correction: v_off_ini = 2310.956 uV, v_off_fin = 2290.791 uV 12:29:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 145.363 uVs 12:29:53 Integrated Voltage Measurement... 12:30:02 Voltage Offset Correction: v_off_ini = 2298.588 uV, v_off_fin = 2288.021 uV 12:30:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -169.915 uVs 12:30:02 Integrated Voltage Measurement... 12:30:11 Voltage Offset Correction: v_off_ini = 2312.276 uV, v_off_fin = 2326.618 uV 12:30:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.062 uVs 12:30:13 I2X Average and RMS of Measurements VT = -143.148 +- 8.253 uVs I2X = 13.170 +- 0.759 uTm^2 12:30:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:21 Integrated Voltage Measurement... 12:30:30 Voltage Offset Correction: v_off_ini = 2293.113 uV, v_off_fin = 2281.690 uV 12:30:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -304.069 uVs 12:30:30 Integrated Voltage Measurement... 12:30:39 Voltage Offset Correction: v_off_ini = 2287.741 uV, v_off_fin = 2296.429 uV 12:30:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.922 uVs 12:30:39 Integrated Voltage Measurement... 12:30:48 Voltage Offset Correction: v_off_ini = 2310.455 uV, v_off_fin = 2311.737 uV 12:30:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.741 uVs 12:30:48 Integrated Voltage Measurement... 12:30:57 Voltage Offset Correction: v_off_ini = 2294.612 uV, v_off_fin = 2339.495 uV 12:30:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.958 uVs 12:30:57 Integrated Voltage Measurement... 12:31:06 Voltage Offset Correction: v_off_ini = 2308.323 uV, v_off_fin = 2292.763 uV 12:31:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.816 uVs 12:31:06 Integrated Voltage Measurement... 12:31:15 Voltage Offset Correction: v_off_ini = 2315.775 uV, v_off_fin = 2328.351 uV 12:31:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.646 uVs 12:31:18 I2Y Average and RMS of Measurements VT = -304.692 +- 4.850 uVs I2Y = -28.032 +- 0.446 uTm^2 12:31:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:33 Integrated Voltage Measurement... 12:31:42 Voltage Offset Correction: v_off_ini = 2306.479 uV, v_off_fin = 2311.428 uV 12:31:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -148.170 uVs 12:31:42 Integrated Voltage Measurement... 12:31:51 Voltage Offset Correction: v_off_ini = 2283.027 uV, v_off_fin = 2283.834 uV 12:31:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.241 uVs 12:31:51 Integrated Voltage Measurement... 12:32:00 Voltage Offset Correction: v_off_ini = 2280.323 uV, v_off_fin = 2268.462 uV 12:32:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -161.100 uVs 12:32:00 Integrated Voltage Measurement... 12:32:09 Voltage Offset Correction: v_off_ini = 2269.814 uV, v_off_fin = 2291.334 uV 12:32:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.453 uVs 12:32:09 Integrated Voltage Measurement... 12:32:18 Voltage Offset Correction: v_off_ini = 2301.704 uV, v_off_fin = 2297.021 uV 12:32:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -174.470 uVs 12:32:18 Integrated Voltage Measurement... 12:32:27 Voltage Offset Correction: v_off_ini = 2276.304 uV, v_off_fin = 2274.782 uV 12:32:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 169.414 uVs 12:32:31 I1X Average and RMS of Measurements VT = -151.141 +- 25.850 uVs I1X = 30.229 +- 5.169 uTm 12:32:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:32:38 Integrated Voltage Measurement... 12:32:47 Voltage Offset Correction: v_off_ini = 2285.201 uV, v_off_fin = 2261.386 uV 12:32:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -169.253 uVs 12:32:47 Integrated Voltage Measurement... 12:32:56 Voltage Offset Correction: v_off_ini = 2295.721 uV, v_off_fin = 2297.727 uV 12:32:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 154.882 uVs 12:32:56 Integrated Voltage Measurement... 12:33:05 Voltage Offset Correction: v_off_ini = 2298.637 uV, v_off_fin = 2301.315 uV 12:33:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.448 uVs 12:33:05 Integrated Voltage Measurement... 12:33:14 Voltage Offset Correction: v_off_ini = 2303.445 uV, v_off_fin = 2310.340 uV 12:33:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.647 uVs 12:33:14 Integrated Voltage Measurement... 12:33:23 Voltage Offset Correction: v_off_ini = 2322.237 uV, v_off_fin = 2320.793 uV 12:33:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.886 uVs 12:33:23 Integrated Voltage Measurement... 12:33:31 Voltage Offset Correction: v_off_ini = 2338.206 uV, v_off_fin = 2326.951 uV 12:33:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 143.838 uVs 12:33:36 I1Y Average and RMS of Measurements VT = -168.992 +- 6.327 uVs I1Y = -33.799 +- 1.265 uTm 12:33:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:33:43 Integrated Voltage Measurement... 12:33:52 Voltage Offset Correction: v_off_ini = 2311.417 uV, v_off_fin = 2297.471 uV 12:33:52 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -191.279 uVs 12:33:52 Integrated Voltage Measurement... 12:34:01 Voltage Offset Correction: v_off_ini = 2325.719 uV, v_off_fin = 2308.977 uV 12:34:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.427 uVs 12:34:01 Integrated Voltage Measurement... 12:34:10 Voltage Offset Correction: v_off_ini = 2306.028 uV, v_off_fin = 2293.983 uV 12:34:10 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -160.766 uVs 12:34:10 Integrated Voltage Measurement... 12:34:19 Voltage Offset Correction: v_off_ini = 2302.521 uV, v_off_fin = 2320.064 uV 12:34:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 135.209 uVs 12:34:20 Integrated Voltage Measurement... 12:34:28 Voltage Offset Correction: v_off_ini = 2297.926 uV, v_off_fin = 2322.676 uV 12:34:29 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -150.735 uVs 12:34:29 Integrated Voltage Measurement... 12:34:38 Voltage Offset Correction: v_off_ini = 2321.946 uV, v_off_fin = 2320.574 uV 12:34:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 146.373 uVs 12:34:40 I2X Average and RMS of Measurements VT = -149.298 +- 1.471 uVs I2X = 13.736 +- 0.134 uTm^2 12:34:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:34:48 Integrated Voltage Measurement... 12:34:57 Voltage Offset Correction: v_off_ini = 2314.531 uV, v_off_fin = 2339.985 uV 12:34:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.097 uVs 12:34:57 Integrated Voltage Measurement... 12:35:06 Voltage Offset Correction: v_off_ini = 2371.771 uV, v_off_fin = 2366.406 uV 12:35:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.628 uVs 12:35:06 Integrated Voltage Measurement... 12:35:15 Voltage Offset Correction: v_off_ini = 2365.577 uV, v_off_fin = 2384.055 uV 12:35:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.262 uVs 12:35:15 Integrated Voltage Measurement... 12:35:24 Voltage Offset Correction: v_off_ini = 2382.590 uV, v_off_fin = 2386.305 uV 12:35:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.871 uVs 12:35:24 Integrated Voltage Measurement... 12:35:33 Voltage Offset Correction: v_off_ini = 2414.777 uV, v_off_fin = 2416.947 uV 12:35:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.780 uVs 12:35:33 Integrated Voltage Measurement... 12:35:42 Voltage Offset Correction: v_off_ini = 2392.679 uV, v_off_fin = 2405.117 uV 12:35:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.899 uVs 12:35:44 I2Y Average and RMS of Measurements VT = -280.256 +- 4.520 uVs I2Y = -25.784 +- 0.416 uTm^2 12:35:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:35:59 Integrated Voltage Measurement... 12:36:08 Voltage Offset Correction: v_off_ini = 2409.739 uV, v_off_fin = 2391.840 uV 12:36:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.316 uVs 12:36:08 Integrated Voltage Measurement... 12:36:17 Voltage Offset Correction: v_off_ini = 2385.380 uV, v_off_fin = 2394.879 uV 12:36:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.623 uVs 12:36:17 Integrated Voltage Measurement... 12:36:26 Voltage Offset Correction: v_off_ini = 2404.814 uV, v_off_fin = 2382.715 uV 12:36:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.545 uVs 12:36:26 Integrated Voltage Measurement... 12:36:35 Voltage Offset Correction: v_off_ini = 2385.200 uV, v_off_fin = 2385.825 uV 12:36:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 172.248 uVs 12:36:35 Integrated Voltage Measurement... 12:36:44 Voltage Offset Correction: v_off_ini = 2392.619 uV, v_off_fin = 2376.620 uV 12:36:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -181.679 uVs 12:36:44 Integrated Voltage Measurement... 12:36:53 Voltage Offset Correction: v_off_ini = 2379.686 uV, v_off_fin = 2375.150 uV 12:36:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 186.441 uVs 12:36:57 I1X Average and RMS of Measurements VT = -160.475 +- 19.025 uVs I1X = 32.095 +- 3.805 uTm 12:37:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:37:04 Integrated Voltage Measurement... 12:37:13 Voltage Offset Correction: v_off_ini = 2380.562 uV, v_off_fin = 2372.382 uV 12:37:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.839 uVs 12:37:13 Integrated Voltage Measurement... 12:37:22 Voltage Offset Correction: v_off_ini = 2398.919 uV, v_off_fin = 2395.515 uV 12:37:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.350 uVs 12:37:22 Integrated Voltage Measurement... 12:37:31 Voltage Offset Correction: v_off_ini = 2380.685 uV, v_off_fin = 2354.364 uV 12:37:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.431 uVs 12:37:31 Integrated Voltage Measurement... 12:37:40 Voltage Offset Correction: v_off_ini = 2389.657 uV, v_off_fin = 2397.581 uV 12:37:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.019 uVs 12:37:40 Integrated Voltage Measurement... 12:37:49 Voltage Offset Correction: v_off_ini = 2361.042 uV, v_off_fin = 2357.068 uV 12:37:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -153.210 uVs 12:37:49 Integrated Voltage Measurement... 12:37:58 Voltage Offset Correction: v_off_ini = 2388.365 uV, v_off_fin = 2396.612 uV 12:37:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.258 uVs 12:38:02 I1Y Average and RMS of Measurements VT = -177.518 +- 12.235 uVs I1Y = -35.504 +- 2.447 uTm 12:38:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:38:10 Integrated Voltage Measurement... 12:38:19 Voltage Offset Correction: v_off_ini = 2378.853 uV, v_off_fin = 2353.745 uV 12:38:19 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -144.527 uVs 12:38:19 Integrated Voltage Measurement... 12:38:28 Voltage Offset Correction: v_off_ini = 2358.177 uV, v_off_fin = 2397.428 uV 12:38:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 156.034 uVs 12:38:28 Integrated Voltage Measurement... 12:38:37 Voltage Offset Correction: v_off_ini = 2382.795 uV, v_off_fin = 2348.225 uV 12:38:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -215.418 uVs 12:38:37 Integrated Voltage Measurement... 12:38:46 Voltage Offset Correction: v_off_ini = 2352.779 uV, v_off_fin = 2384.907 uV 12:38:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 129.056 uVs 12:38:46 Integrated Voltage Measurement... 12:38:55 Voltage Offset Correction: v_off_ini = 2369.747 uV, v_off_fin = 2373.886 uV 12:38:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -129.526 uVs 12:38:55 Integrated Voltage Measurement... 12:39:04 Voltage Offset Correction: v_off_ini = 2377.388 uV, v_off_fin = 2376.537 uV 12:39:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.002 uVs 12:39:07 I2X Average and RMS of Measurements VT = -154.927 +- 12.670 uVs I2X = 14.253 +- 1.166 uTm^2 12:39:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:39:14 Integrated Voltage Measurement... 12:39:23 Voltage Offset Correction: v_off_ini = 2383.524 uV, v_off_fin = 2382.788 uV 12:39:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.625 uVs 12:39:23 Integrated Voltage Measurement... 12:39:32 Voltage Offset Correction: v_off_ini = 2396.605 uV, v_off_fin = 2399.910 uV 12:39:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.379 uVs 12:39:32 Integrated Voltage Measurement... 12:39:41 Voltage Offset Correction: v_off_ini = 2377.315 uV, v_off_fin = 2396.475 uV 12:39:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.155 uVs 12:39:41 Integrated Voltage Measurement... 12:39:50 Voltage Offset Correction: v_off_ini = 2391.062 uV, v_off_fin = 2380.154 uV 12:39:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.147 uVs 12:39:50 Integrated Voltage Measurement... 12:39:59 Voltage Offset Correction: v_off_ini = 2396.544 uV, v_off_fin = 2402.173 uV 12:39:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.207 uVs 12:39:59 Integrated Voltage Measurement... 12:40:08 Voltage Offset Correction: v_off_ini = 2407.930 uV, v_off_fin = 2409.688 uV 12:40:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.625 uVs 12:40:11 I2Y Average and RMS of Measurements VT = -294.856 +- 24.620 uVs I2Y = -27.127 +- 2.265 uTm^2 12:40:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:40:26 Integrated Voltage Measurement... 12:40:35 Voltage Offset Correction: v_off_ini = 2410.982 uV, v_off_fin = 2407.313 uV 12:40:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.226 uVs 12:40:35 Integrated Voltage Measurement... 12:40:44 Voltage Offset Correction: v_off_ini = 2406.549 uV, v_off_fin = 2407.243 uV 12:40:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 137.013 uVs 12:40:44 Integrated Voltage Measurement... 12:40:53 Voltage Offset Correction: v_off_ini = 2425.760 uV, v_off_fin = 2407.995 uV 12:40:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.086 uVs 12:40:53 Integrated Voltage Measurement... 12:41:02 Voltage Offset Correction: v_off_ini = 2399.759 uV, v_off_fin = 2400.292 uV 12:41:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.088 uVs 12:41:02 Integrated Voltage Measurement... 12:41:11 Voltage Offset Correction: v_off_ini = 2398.673 uV, v_off_fin = 2392.362 uV 12:41:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -169.329 uVs 12:41:11 Integrated Voltage Measurement... 12:41:20 Voltage Offset Correction: v_off_ini = 2383.117 uV, v_off_fin = 2386.309 uV 12:41:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.766 uVs 12:41:24 I1X Average and RMS of Measurements VT = -145.085 +- 7.760 uVs I1X = 29.017 +- 1.552 uTm 12:41:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:41:31 Integrated Voltage Measurement... 12:41:40 Voltage Offset Correction: v_off_ini = 2415.348 uV, v_off_fin = 2396.195 uV 12:41:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.695 uVs 12:41:40 Integrated Voltage Measurement... 12:41:49 Voltage Offset Correction: v_off_ini = 2402.477 uV, v_off_fin = 2393.018 uV 12:41:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 177.564 uVs 12:41:49 Integrated Voltage Measurement... 12:41:58 Voltage Offset Correction: v_off_ini = 2410.859 uV, v_off_fin = 2405.747 uV 12:41:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.488 uVs 12:41:58 Integrated Voltage Measurement... 12:42:07 Voltage Offset Correction: v_off_ini = 2396.737 uV, v_off_fin = 2410.849 uV 12:42:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 150.212 uVs 12:42:07 Integrated Voltage Measurement... 12:42:16 Voltage Offset Correction: v_off_ini = 2397.522 uV, v_off_fin = 2394.786 uV 12:42:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -179.943 uVs 12:42:16 Integrated Voltage Measurement... 12:42:25 Voltage Offset Correction: v_off_ini = 2411.868 uV, v_off_fin = 2391.499 uV 12:42:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.666 uVs 12:42:29 I1Y Average and RMS of Measurements VT = -180.762 +- 7.542 uVs I1Y = -36.152 +- 1.508 uTm 12:42:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:42:37 Integrated Voltage Measurement... 12:42:46 Voltage Offset Correction: v_off_ini = 2404.530 uV, v_off_fin = 2387.143 uV 12:42:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -148.950 uVs 12:42:46 Integrated Voltage Measurement... 12:42:55 Voltage Offset Correction: v_off_ini = 2381.018 uV, v_off_fin = 2402.944 uV 12:42:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 142.920 uVs 12:42:55 Integrated Voltage Measurement... 12:43:04 Voltage Offset Correction: v_off_ini = 2392.451 uV, v_off_fin = 2383.011 uV 12:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -148.565 uVs 12:43:04 Integrated Voltage Measurement... 12:43:13 Voltage Offset Correction: v_off_ini = 2384.352 uV, v_off_fin = 2386.708 uV 12:43:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.403 uVs 12:43:13 Integrated Voltage Measurement... 12:43:22 Voltage Offset Correction: v_off_ini = 2385.361 uV, v_off_fin = 2373.048 uV 12:43:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -139.039 uVs 12:43:22 Integrated Voltage Measurement... 12:43:31 Voltage Offset Correction: v_off_ini = 2373.320 uV, v_off_fin = 2383.659 uV 12:43:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 156.710 uVs 12:43:33 I2X Average and RMS of Measurements VT = -148.931 +- 2.973 uVs I2X = 13.702 +- 0.274 uTm^2 12:43:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:43:41 Integrated Voltage Measurement... 12:43:50 Voltage Offset Correction: v_off_ini = 2390.719 uV, v_off_fin = 2375.832 uV 12:43:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.034 uVs 12:43:50 Integrated Voltage Measurement... 12:43:59 Voltage Offset Correction: v_off_ini = 2392.210 uV, v_off_fin = 2402.166 uV 12:43:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.139 uVs 12:43:59 Integrated Voltage Measurement... 12:44:08 Voltage Offset Correction: v_off_ini = 2394.699 uV, v_off_fin = 2390.112 uV 12:44:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.464 uVs 12:44:08 Integrated Voltage Measurement... 12:44:17 Voltage Offset Correction: v_off_ini = 2375.583 uV, v_off_fin = 2382.507 uV 12:44:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.220 uVs 12:44:17 Integrated Voltage Measurement... 12:44:26 Voltage Offset Correction: v_off_ini = 2396.374 uV, v_off_fin = 2375.163 uV 12:44:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.220 uVs 12:44:26 Integrated Voltage Measurement... 12:44:35 Voltage Offset Correction: v_off_ini = 2378.663 uV, v_off_fin = 2396.069 uV 12:44:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.774 uVs 12:44:37 I2Y Average and RMS of Measurements VT = -272.475 +- 4.331 uVs I2Y = -25.068 +- 0.398 uTm^2 12:44:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:44:54 Integrated Voltage Measurement... 12:45:03 Voltage Offset Correction: v_off_ini = 2375.663 uV, v_off_fin = 2377.352 uV 12:45:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.364 uVs 12:45:03 Integrated Voltage Measurement... 12:45:12 Voltage Offset Correction: v_off_ini = 2395.372 uV, v_off_fin = 2416.928 uV 12:45:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 163.146 uVs 12:45:12 Integrated Voltage Measurement... 12:45:21 Voltage Offset Correction: v_off_ini = 2400.761 uV, v_off_fin = 2406.663 uV 12:45:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.944 uVs 12:45:21 Integrated Voltage Measurement... 12:45:30 Voltage Offset Correction: v_off_ini = 2390.920 uV, v_off_fin = 2417.594 uV 12:45:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.794 uVs 12:45:30 Integrated Voltage Measurement... 12:45:39 Voltage Offset Correction: v_off_ini = 2399.598 uV, v_off_fin = 2406.533 uV 12:45:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.697 uVs 12:45:39 Integrated Voltage Measurement... 12:45:48 Voltage Offset Correction: v_off_ini = 2406.446 uV, v_off_fin = 2400.809 uV 12:45:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 189.657 uVs 12:45:52 I1X Average and RMS of Measurements VT = -149.767 +- 20.373 uVs I1X = 29.953 +- 4.075 uTm 12:45:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:45:59 Integrated Voltage Measurement... 12:46:08 Voltage Offset Correction: v_off_ini = 2412.399 uV, v_off_fin = 2377.335 uV 12:46:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -153.578 uVs 12:46:08 Integrated Voltage Measurement... 12:46:17 Voltage Offset Correction: v_off_ini = 2397.517 uV, v_off_fin = 2396.996 uV 12:46:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.534 uVs 12:46:17 Integrated Voltage Measurement... 12:46:26 Voltage Offset Correction: v_off_ini = 2384.257 uV, v_off_fin = 2388.040 uV 12:46:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.859 uVs 12:46:26 Integrated Voltage Measurement... 12:46:35 Voltage Offset Correction: v_off_ini = 2387.058 uV, v_off_fin = 2394.354 uV 12:46:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 170.510 uVs 12:46:35 Integrated Voltage Measurement... 12:46:44 Voltage Offset Correction: v_off_ini = 2381.919 uV, v_off_fin = 2390.810 uV 12:46:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -155.645 uVs 12:46:44 Integrated Voltage Measurement... 12:46:53 Voltage Offset Correction: v_off_ini = 2401.999 uV, v_off_fin = 2402.792 uV 12:46:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 164.892 uVs 12:46:57 I1Y Average and RMS of Measurements VT = -162.503 +- 3.220 uVs I1Y = -32.501 +- 0.645 uTm 12:47:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:47:05 Integrated Voltage Measurement... 12:47:14 Voltage Offset Correction: v_off_ini = 2392.412 uV, v_off_fin = 2405.577 uV 12:47:14 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -129.793 uVs 12:47:14 Integrated Voltage Measurement... 12:47:23 Voltage Offset Correction: v_off_ini = 2400.788 uV, v_off_fin = 2416.463 uV 12:47:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 162.920 uVs 12:47:23 Integrated Voltage Measurement... 12:47:32 Voltage Offset Correction: v_off_ini = 2404.165 uV, v_off_fin = 2415.065 uV 12:47:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -146.900 uVs 12:47:32 Integrated Voltage Measurement... 12:47:41 Voltage Offset Correction: v_off_ini = 2399.250 uV, v_off_fin = 2419.420 uV 12:47:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 179.723 uVs 12:47:41 Integrated Voltage Measurement... 12:47:50 Voltage Offset Correction: v_off_ini = 2398.798 uV, v_off_fin = 2406.079 uV 12:47:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -130.580 uVs 12:47:50 Integrated Voltage Measurement... 12:47:59 Voltage Offset Correction: v_off_ini = 2399.339 uV, v_off_fin = 2389.999 uV 12:47:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.201 uVs 12:48:01 I2X Average and RMS of Measurements VT = -148.519 +- 11.298 uVs I2X = 13.664 +- 1.039 uTm^2 12:48:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:48:09 Integrated Voltage Measurement... 12:48:18 Voltage Offset Correction: v_off_ini = 2400.296 uV, v_off_fin = 2419.664 uV 12:48:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.086 uVs 12:48:18 Integrated Voltage Measurement... 12:48:27 Voltage Offset Correction: v_off_ini = 2408.572 uV, v_off_fin = 2419.959 uV 12:48:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.519 uVs 12:48:27 Integrated Voltage Measurement... 12:48:36 Voltage Offset Correction: v_off_ini = 2407.541 uV, v_off_fin = 2408.417 uV 12:48:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.156 uVs 12:48:36 Integrated Voltage Measurement... 12:48:45 Voltage Offset Correction: v_off_ini = 2438.797 uV, v_off_fin = 2427.649 uV 12:48:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.456 uVs 12:48:45 Integrated Voltage Measurement... 12:48:54 Voltage Offset Correction: v_off_ini = 2435.363 uV, v_off_fin = 2440.544 uV 12:48:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.372 uVs 12:48:54 Integrated Voltage Measurement... 12:49:03 Voltage Offset Correction: v_off_ini = 2442.520 uV, v_off_fin = 2452.118 uV 12:49:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.177 uVs 12:49:05 I2Y Average and RMS of Measurements VT = -278.128 +- 25.768 uVs I2Y = -25.588 +- 2.371 uTm^2 12:49:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:49:21 Integrated Voltage Measurement... 12:49:30 Voltage Offset Correction: v_off_ini = 2407.298 uV, v_off_fin = 2403.717 uV 12:49:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -146.132 uVs 12:49:30 Integrated Voltage Measurement... 12:49:39 Voltage Offset Correction: v_off_ini = 2425.917 uV, v_off_fin = 2443.867 uV 12:49:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.126 uVs 12:49:40 Integrated Voltage Measurement... 12:49:48 Voltage Offset Correction: v_off_ini = 2437.189 uV, v_off_fin = 2475.008 uV 12:49:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.752 uVs 12:49:49 Integrated Voltage Measurement... 12:49:57 Voltage Offset Correction: v_off_ini = 2447.193 uV, v_off_fin = 2429.658 uV 12:49:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 153.261 uVs 12:49:58 Integrated Voltage Measurement... 12:50:06 Voltage Offset Correction: v_off_ini = 2449.534 uV, v_off_fin = 2435.337 uV 12:50:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -156.854 uVs 12:50:07 Integrated Voltage Measurement... 12:50:15 Voltage Offset Correction: v_off_ini = 2417.476 uV, v_off_fin = 2462.222 uV 12:50:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.115 uVs 12:50:20 I1X Average and RMS of Measurements VT = -138.873 +- 3.892 uVs I1X = 27.775 +- 0.778 uTm 12:50:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:50:26 Integrated Voltage Measurement... 12:50:35 Voltage Offset Correction: v_off_ini = 2435.309 uV, v_off_fin = 2426.849 uV 12:50:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.431 uVs 12:50:35 Integrated Voltage Measurement... 12:50:44 Voltage Offset Correction: v_off_ini = 2432.883 uV, v_off_fin = 2443.342 uV 12:50:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.974 uVs 12:50:44 Integrated Voltage Measurement... 12:50:53 Voltage Offset Correction: v_off_ini = 2420.362 uV, v_off_fin = 2407.285 uV 12:50:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -149.533 uVs 12:50:53 Integrated Voltage Measurement... 12:51:02 Voltage Offset Correction: v_off_ini = 2451.554 uV, v_off_fin = 2463.731 uV 12:51:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 160.022 uVs 12:51:02 Integrated Voltage Measurement... 12:51:11 Voltage Offset Correction: v_off_ini = 2442.397 uV, v_off_fin = 2449.377 uV 12:51:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.901 uVs 12:51:11 Integrated Voltage Measurement... 12:51:20 Voltage Offset Correction: v_off_ini = 2494.795 uV, v_off_fin = 2486.245 uV 12:51:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.994 uVs 12:51:25 I1Y Average and RMS of Measurements VT = -177.143 +- 16.782 uVs I1Y = -35.429 +- 3.356 uTm 12:51:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:51:32 Integrated Voltage Measurement... 12:51:41 Voltage Offset Correction: v_off_ini = 2459.441 uV, v_off_fin = 2456.017 uV 12:51:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -157.042 uVs 12:51:41 Integrated Voltage Measurement... 12:51:50 Voltage Offset Correction: v_off_ini = 2467.317 uV, v_off_fin = 2478.847 uV 12:51:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 130.486 uVs 12:51:50 Integrated Voltage Measurement... 12:51:59 Voltage Offset Correction: v_off_ini = 2463.047 uV, v_off_fin = 2449.616 uV 12:51:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -147.716 uVs 12:51:59 Integrated Voltage Measurement... 12:52:08 Voltage Offset Correction: v_off_ini = 2478.843 uV, v_off_fin = 2480.153 uV 12:52:08 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 178.357 uVs 12:52:08 Integrated Voltage Measurement... 12:52:17 Voltage Offset Correction: v_off_ini = 2482.658 uV, v_off_fin = 2486.287 uV 12:52:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.994 uVs 12:52:17 Integrated Voltage Measurement... 12:52:26 Voltage Offset Correction: v_off_ini = 2494.696 uV, v_off_fin = 2473.362 uV 12:52:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 159.850 uVs 12:52:29 I2X Average and RMS of Measurements VT = -147.074 +- 11.914 uVs I2X = 13.531 +- 1.097 uTm^2 12:52:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:52:36 Integrated Voltage Measurement... 12:52:45 Voltage Offset Correction: v_off_ini = 2448.404 uV, v_off_fin = 2465.034 uV 12:52:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.367 uVs 12:52:45 Integrated Voltage Measurement... 12:52:54 Voltage Offset Correction: v_off_ini = 2460.577 uV, v_off_fin = 2452.636 uV 12:52:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 286.076 uVs 12:52:55 Integrated Voltage Measurement... 12:53:04 Voltage Offset Correction: v_off_ini = 2450.609 uV, v_off_fin = 2435.614 uV 12:53:04 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -266.493 uVs 12:53:04 Integrated Voltage Measurement... 12:53:13 Voltage Offset Correction: v_off_ini = 2449.371 uV, v_off_fin = 2470.839 uV 12:53:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.220 uVs 12:53:13 Integrated Voltage Measurement... 12:53:22 Voltage Offset Correction: v_off_ini = 2451.515 uV, v_off_fin = 2447.705 uV 12:53:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.177 uVs 12:53:22 Integrated Voltage Measurement... 12:53:31 Voltage Offset Correction: v_off_ini = 2447.546 uV, v_off_fin = 2458.050 uV 12:53:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 258.761 uVs 12:53:33 I2Y Average and RMS of Measurements VT = -263.182 +- 9.164 uVs I2Y = -24.214 +- 0.843 uTm^2 12:53:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:53:51 Integrated Voltage Measurement... 12:54:00 Voltage Offset Correction: v_off_ini = 2464.775 uV, v_off_fin = 2499.145 uV 12:54:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.264 uVs 12:54:00 Integrated Voltage Measurement... 12:54:09 Voltage Offset Correction: v_off_ini = 2511.636 uV, v_off_fin = 2511.856 uV 12:54:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.474 uVs 12:54:09 Integrated Voltage Measurement... 12:54:18 Voltage Offset Correction: v_off_ini = 2477.423 uV, v_off_fin = 2485.902 uV 12:54:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -177.644 uVs 12:54:18 Integrated Voltage Measurement... 12:54:27 Voltage Offset Correction: v_off_ini = 2457.325 uV, v_off_fin = 2461.095 uV 12:54:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.838 uVs 12:54:27 Integrated Voltage Measurement... 12:54:36 Voltage Offset Correction: v_off_ini = 2436.188 uV, v_off_fin = 2451.163 uV 12:54:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.042 uVs 12:54:36 Integrated Voltage Measurement... 12:54:45 Voltage Offset Correction: v_off_ini = 2454.382 uV, v_off_fin = 2476.290 uV 12:54:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.346 uVs 12:54:50 I1X Average and RMS of Measurements VT = -136.768 +- 13.698 uVs I1X = 27.354 +- 2.740 uTm 12:54:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:54:56 Integrated Voltage Measurement... 12:55:05 Voltage Offset Correction: v_off_ini = 2485.257 uV, v_off_fin = 2472.397 uV 12:55:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.711 uVs 12:55:05 Integrated Voltage Measurement... 12:55:14 Voltage Offset Correction: v_off_ini = 2479.891 uV, v_off_fin = 2475.219 uV 12:55:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.732 uVs 12:55:14 Integrated Voltage Measurement... 12:55:23 Voltage Offset Correction: v_off_ini = 2479.406 uV, v_off_fin = 2481.432 uV 12:55:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.551 uVs 12:55:23 Integrated Voltage Measurement... 12:55:32 Voltage Offset Correction: v_off_ini = 2497.002 uV, v_off_fin = 2503.012 uV 12:55:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 173.688 uVs 12:55:32 Integrated Voltage Measurement... 12:55:41 Voltage Offset Correction: v_off_ini = 2482.713 uV, v_off_fin = 2459.978 uV 12:55:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.166 uVs 12:55:41 Integrated Voltage Measurement... 12:55:50 Voltage Offset Correction: v_off_ini = 2496.014 uV, v_off_fin = 2501.180 uV 12:55:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 174.899 uVs 12:55:54 I1Y Average and RMS of Measurements VT = -181.791 +- 7.975 uVs I1Y = -36.359 +- 1.595 uTm 12:56:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:56:02 Integrated Voltage Measurement... 12:56:11 Voltage Offset Correction: v_off_ini = 2508.988 uV, v_off_fin = 2475.626 uV 12:56:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -150.775 uVs 12:56:11 Integrated Voltage Measurement... 12:56:20 Voltage Offset Correction: v_off_ini = 2499.825 uV, v_off_fin = 2493.096 uV 12:56:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 126.243 uVs 12:56:20 Integrated Voltage Measurement... 12:56:29 Voltage Offset Correction: v_off_ini = 2484.506 uV, v_off_fin = 2486.637 uV 12:56:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -153.297 uVs 12:56:29 Integrated Voltage Measurement... 12:56:38 Voltage Offset Correction: v_off_ini = 2487.186 uV, v_off_fin = 2483.481 uV 12:56:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.911 uVs 12:56:38 Integrated Voltage Measurement... 12:56:47 Voltage Offset Correction: v_off_ini = 2465.714 uV, v_off_fin = 2490.439 uV 12:56:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -164.427 uVs 12:56:47 Integrated Voltage Measurement... 12:56:56 Voltage Offset Correction: v_off_ini = 2476.970 uV, v_off_fin = 2486.182 uV 12:56:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 157.232 uVs 12:56:59 I2X Average and RMS of Measurements VT = -145.981 +- 10.500 uVs I2X = 13.430 +- 0.966 uTm^2 12:57:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:57:06 Integrated Voltage Measurement... 12:57:15 Voltage Offset Correction: v_off_ini = 2473.288 uV, v_off_fin = 2460.482 uV 12:57:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.530 uVs 12:57:15 Integrated Voltage Measurement... 12:57:24 Voltage Offset Correction: v_off_ini = 2456.746 uV, v_off_fin = 2471.826 uV 12:57:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.982 uVs 12:57:24 Integrated Voltage Measurement... 12:57:33 Voltage Offset Correction: v_off_ini = 2473.709 uV, v_off_fin = 2462.154 uV 12:57:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.977 uVs 12:57:33 Integrated Voltage Measurement... 12:57:42 Voltage Offset Correction: v_off_ini = 2444.655 uV, v_off_fin = 2446.247 uV 12:57:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.890 uVs 12:57:42 Integrated Voltage Measurement... 12:57:51 Voltage Offset Correction: v_off_ini = 2457.484 uV, v_off_fin = 2467.998 uV 12:57:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.810 uVs 12:57:51 Integrated Voltage Measurement... 12:58:00 Voltage Offset Correction: v_off_ini = 2453.533 uV, v_off_fin = 2464.880 uV 12:58:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.054 uVs 12:58:03 I2Y Average and RMS of Measurements VT = -257.707 +- 11.121 uVs I2Y = -23.709 +- 1.023 uTm^2 12:58:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:58:21 Integrated Voltage Measurement... 12:58:30 Voltage Offset Correction: v_off_ini = 2472.685 uV, v_off_fin = 2474.509 uV 12:58:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.135 uVs 12:58:30 Integrated Voltage Measurement... 12:58:39 Voltage Offset Correction: v_off_ini = 2473.453 uV, v_off_fin = 2483.197 uV 12:58:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.855 uVs 12:58:39 Integrated Voltage Measurement... 12:58:48 Voltage Offset Correction: v_off_ini = 2451.790 uV, v_off_fin = 2471.637 uV 12:58:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -151.069 uVs 12:58:48 Integrated Voltage Measurement... 12:58:57 Voltage Offset Correction: v_off_ini = 2486.465 uV, v_off_fin = 2475.805 uV 12:58:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 143.207 uVs 12:58:57 Integrated Voltage Measurement... 12:59:06 Voltage Offset Correction: v_off_ini = 2518.900 uV, v_off_fin = 2483.622 uV 12:59:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.848 uVs 12:59:06 Integrated Voltage Measurement... 12:59:15 Voltage Offset Correction: v_off_ini = 2477.157 uV, v_off_fin = 2465.343 uV 12:59:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.837 uVs 12:59:20 I1X Average and RMS of Measurements VT = -143.325 +- 2.936 uVs I1X = 28.665 +- 0.587 uTm 12:59:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:59:26 Integrated Voltage Measurement... 12:59:35 Voltage Offset Correction: v_off_ini = 2485.775 uV, v_off_fin = 2482.455 uV 12:59:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -161.985 uVs 12:59:35 Integrated Voltage Measurement... 12:59:44 Voltage Offset Correction: v_off_ini = 2483.818 uV, v_off_fin = 2508.479 uV 12:59:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.492 uVs 12:59:44 Integrated Voltage Measurement... 12:59:53 Voltage Offset Correction: v_off_ini = 2525.472 uV, v_off_fin = 2499.211 uV 12:59:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.552 uVs 12:59:53 Integrated Voltage Measurement... 13:00:02 Voltage Offset Correction: v_off_ini = 2493.123 uV, v_off_fin = 2504.085 uV 13:00:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.983 uVs 13:00:02 Integrated Voltage Measurement... 13:00:11 Voltage Offset Correction: v_off_ini = 2478.953 uV, v_off_fin = 2478.258 uV 13:00:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -196.837 uVs 13:00:11 Integrated Voltage Measurement... 13:00:20 Voltage Offset Correction: v_off_ini = 2484.479 uV, v_off_fin = 2495.008 uV 13:00:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.015 uVs 13:00:24 I1Y Average and RMS of Measurements VT = -185.644 +- 11.625 uVs I1Y = -37.129 +- 2.325 uTm 13:00:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:00:32 Integrated Voltage Measurement... 13:00:41 Voltage Offset Correction: v_off_ini = 2463.804 uV, v_off_fin = 2467.512 uV 13:00:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.840 uVs 13:00:41 Integrated Voltage Measurement... 13:00:50 Voltage Offset Correction: v_off_ini = 2457.636 uV, v_off_fin = 2488.018 uV 13:00:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.094 uVs 13:00:50 Integrated Voltage Measurement... 13:00:59 Voltage Offset Correction: v_off_ini = 2471.404 uV, v_off_fin = 2463.906 uV 13:00:59 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -149.355 uVs 13:00:59 Integrated Voltage Measurement... 13:01:08 Voltage Offset Correction: v_off_ini = 2470.844 uV, v_off_fin = 2447.874 uV 13:01:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 147.471 uVs 13:01:08 Integrated Voltage Measurement... 13:01:17 Voltage Offset Correction: v_off_ini = 2466.260 uV, v_off_fin = 2456.683 uV 13:01:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.803 uVs 13:01:17 Integrated Voltage Measurement... 13:01:26 Voltage Offset Correction: v_off_ini = 2474.484 uV, v_off_fin = 2474.400 uV 13:01:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.053 uVs 13:01:29 I2X Average and RMS of Measurements VT = -137.769 +- 7.622 uVs I2X = 12.675 +- 0.702 uTm^2 13:01:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:01:36 Integrated Voltage Measurement... 13:01:45 Voltage Offset Correction: v_off_ini = 2454.971 uV, v_off_fin = 2450.346 uV 13:01:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.724 uVs 13:01:45 Integrated Voltage Measurement... 13:01:54 Voltage Offset Correction: v_off_ini = 2429.690 uV, v_off_fin = 2453.131 uV 13:01:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.346 uVs 13:01:54 Integrated Voltage Measurement... 13:02:03 Voltage Offset Correction: v_off_ini = 2452.291 uV, v_off_fin = 2483.186 uV 13:02:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.544 uVs 13:02:03 Integrated Voltage Measurement... 13:02:12 Voltage Offset Correction: v_off_ini = 2477.186 uV, v_off_fin = 2461.596 uV 13:02:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.441 uVs 13:02:12 Integrated Voltage Measurement... 13:02:21 Voltage Offset Correction: v_off_ini = 2476.445 uV, v_off_fin = 2484.977 uV 13:02:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.126 uVs 13:02:21 Integrated Voltage Measurement... 13:02:30 Voltage Offset Correction: v_off_ini = 2476.087 uV, v_off_fin = 2469.823 uV 13:02:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.717 uVs 13:02:33 I2Y Average and RMS of Measurements VT = -245.483 +- 7.894 uVs I2Y = -22.584 +- 0.726 uTm^2 13:02:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:02:51 Integrated Voltage Measurement... 13:03:00 Voltage Offset Correction: v_off_ini = 2478.581 uV, v_off_fin = 2483.119 uV 13:03:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.766 uVs 13:03:00 Integrated Voltage Measurement... 13:03:09 Voltage Offset Correction: v_off_ini = 2471.378 uV, v_off_fin = 2474.079 uV 13:03:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.478 uVs 13:03:09 Integrated Voltage Measurement... 13:03:18 Voltage Offset Correction: v_off_ini = 2445.769 uV, v_off_fin = 2460.348 uV 13:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.410 uVs 13:03:18 Integrated Voltage Measurement... 13:03:27 Voltage Offset Correction: v_off_ini = 2473.206 uV, v_off_fin = 2460.474 uV 13:03:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.164 uVs 13:03:27 Integrated Voltage Measurement... 13:03:36 Voltage Offset Correction: v_off_ini = 2440.549 uV, v_off_fin = 2422.497 uV 13:03:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.474 uVs 13:03:36 Integrated Voltage Measurement... 13:03:45 Voltage Offset Correction: v_off_ini = 2453.700 uV, v_off_fin = 2451.738 uV 13:03:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 116.659 uVs 13:03:49 I1X Average and RMS of Measurements VT = -124.325 +- 12.922 uVs I1X = 24.865 +- 2.584 uTm 13:03:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:03:56 Integrated Voltage Measurement... 13:04:05 Voltage Offset Correction: v_off_ini = 2448.006 uV, v_off_fin = 2443.289 uV 13:04:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -171.849 uVs 13:04:05 Integrated Voltage Measurement... 13:04:14 Voltage Offset Correction: v_off_ini = 2439.412 uV, v_off_fin = 2467.798 uV 13:04:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.490 uVs 13:04:14 Integrated Voltage Measurement... 13:04:23 Voltage Offset Correction: v_off_ini = 2454.297 uV, v_off_fin = 2468.242 uV 13:04:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.683 uVs 13:04:23 Integrated Voltage Measurement... 13:04:32 Voltage Offset Correction: v_off_ini = 2460.704 uV, v_off_fin = 2486.016 uV 13:04:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.992 uVs 13:04:32 Integrated Voltage Measurement... 13:04:41 Voltage Offset Correction: v_off_ini = 2464.942 uV, v_off_fin = 2472.093 uV 13:04:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.931 uVs 13:04:41 Integrated Voltage Measurement... 13:04:50 Voltage Offset Correction: v_off_ini = 2482.256 uV, v_off_fin = 2474.303 uV 13:04:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 191.077 uVs 13:04:54 I1Y Average and RMS of Measurements VT = -193.004 +- 11.927 uVs I1Y = -38.601 +- 2.385 uTm 13:04:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:05:02 Integrated Voltage Measurement... 13:05:11 Voltage Offset Correction: v_off_ini = 2489.062 uV, v_off_fin = 2470.445 uV 13:05:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.750 uVs 13:05:11 Integrated Voltage Measurement... 13:05:20 Voltage Offset Correction: v_off_ini = 2457.755 uV, v_off_fin = 2483.378 uV 13:05:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 144.401 uVs 13:05:20 Integrated Voltage Measurement... 13:05:29 Voltage Offset Correction: v_off_ini = 2474.299 uV, v_off_fin = 2450.345 uV 13:05:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -131.209 uVs 13:05:29 Integrated Voltage Measurement... 13:05:38 Voltage Offset Correction: v_off_ini = 2459.390 uV, v_off_fin = 2448.994 uV 13:05:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 126.943 uVs 13:05:38 Integrated Voltage Measurement... 13:05:47 Voltage Offset Correction: v_off_ini = 2449.372 uV, v_off_fin = 2425.784 uV 13:05:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -135.644 uVs 13:05:47 Integrated Voltage Measurement... 13:05:56 Voltage Offset Correction: v_off_ini = 2461.367 uV, v_off_fin = 2466.096 uV 13:05:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.863 uVs 13:05:58 I2X Average and RMS of Measurements VT = -121.468 +- 9.380 uVs I2X = 11.175 +- 0.863 uTm^2 13:06:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:06:06 Integrated Voltage Measurement... 13:06:15 Voltage Offset Correction: v_off_ini = 2456.660 uV, v_off_fin = 2448.303 uV 13:06:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.981 uVs 13:06:15 Integrated Voltage Measurement... 13:06:24 Voltage Offset Correction: v_off_ini = 2464.122 uV, v_off_fin = 2457.874 uV 13:06:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.936 uVs 13:06:24 Integrated Voltage Measurement... 13:06:33 Voltage Offset Correction: v_off_ini = 2455.487 uV, v_off_fin = 2443.742 uV 13:06:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.318 uVs 13:06:33 Integrated Voltage Measurement... 13:06:42 Voltage Offset Correction: v_off_ini = 2463.571 uV, v_off_fin = 2476.729 uV 13:06:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.569 uVs 13:06:42 Integrated Voltage Measurement... 13:06:51 Voltage Offset Correction: v_off_ini = 2478.648 uV, v_off_fin = 2476.126 uV 13:06:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.383 uVs 13:06:51 Integrated Voltage Measurement... 13:07:00 Voltage Offset Correction: v_off_ini = 2474.342 uV, v_off_fin = 2478.341 uV 13:07:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.860 uVs 13:07:03 I2Y Average and RMS of Measurements VT = -264.841 +- 7.586 uVs I2Y = -24.365 +- 0.698 uTm^2 13:07:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:07:21 Integrated Voltage Measurement... 13:07:30 Voltage Offset Correction: v_off_ini = 2501.404 uV, v_off_fin = 2467.371 uV 13:07:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.894 uVs 13:07:30 Integrated Voltage Measurement... 13:07:39 Voltage Offset Correction: v_off_ini = 2470.697 uV, v_off_fin = 2482.470 uV 13:07:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 116.470 uVs 13:07:39 Integrated Voltage Measurement... 13:07:48 Voltage Offset Correction: v_off_ini = 2449.941 uV, v_off_fin = 2476.016 uV 13:07:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.918 uVs 13:07:48 Integrated Voltage Measurement... 13:07:57 Voltage Offset Correction: v_off_ini = 2496.801 uV, v_off_fin = 2492.575 uV 13:07:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.679 uVs 13:07:57 Integrated Voltage Measurement... 13:08:06 Voltage Offset Correction: v_off_ini = 2493.332 uV, v_off_fin = 2500.902 uV 13:08:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.267 uVs 13:08:06 Integrated Voltage Measurement... 13:08:15 Voltage Offset Correction: v_off_ini = 2503.045 uV, v_off_fin = 2489.202 uV 13:08:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 157.142 uVs 13:08:19 I1X Average and RMS of Measurements VT = -131.561 +- 11.372 uVs I1X = 26.313 +- 2.274 uTm 13:08:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:08:26 Integrated Voltage Measurement... 13:08:35 Voltage Offset Correction: v_off_ini = 2477.334 uV, v_off_fin = 2510.905 uV 13:08:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -197.641 uVs 13:08:35 Integrated Voltage Measurement... 13:08:44 Voltage Offset Correction: v_off_ini = 2494.432 uV, v_off_fin = 2532.037 uV 13:08:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 146.961 uVs 13:08:44 Integrated Voltage Measurement... 13:08:53 Voltage Offset Correction: v_off_ini = 2511.459 uV, v_off_fin = 2510.457 uV 13:08:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.337 uVs 13:08:53 Integrated Voltage Measurement... 13:09:02 Voltage Offset Correction: v_off_ini = 2532.788 uV, v_off_fin = 2540.452 uV 13:09:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.613 uVs 13:09:02 Integrated Voltage Measurement... 13:09:11 Voltage Offset Correction: v_off_ini = 2528.619 uV, v_off_fin = 2509.660 uV 13:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.922 uVs 13:09:11 Integrated Voltage Measurement... 13:09:20 Voltage Offset Correction: v_off_ini = 2528.538 uV, v_off_fin = 2547.173 uV 13:09:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.716 uVs 13:09:24 I1Y Average and RMS of Measurements VT = -190.032 +- 13.166 uVs I1Y = -38.007 +- 2.632 uTm 13:09:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:09:32 Integrated Voltage Measurement... 13:09:41 Voltage Offset Correction: v_off_ini = 2501.734 uV, v_off_fin = 2533.514 uV 13:09:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.886 uVs 13:09:41 Integrated Voltage Measurement... 13:09:50 Voltage Offset Correction: v_off_ini = 2526.784 uV, v_off_fin = 2543.803 uV 13:09:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.064 uVs 13:09:50 Integrated Voltage Measurement... 13:09:59 Voltage Offset Correction: v_off_ini = 2540.141 uV, v_off_fin = 2522.393 uV 13:09:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.671 uVs 13:09:59 Integrated Voltage Measurement... 13:10:08 Voltage Offset Correction: v_off_ini = 2541.398 uV, v_off_fin = 2554.280 uV 13:10:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 107.659 uVs 13:10:08 Integrated Voltage Measurement... 13:10:17 Voltage Offset Correction: v_off_ini = 2565.170 uV, v_off_fin = 2540.541 uV 13:10:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -127.884 uVs 13:10:17 Integrated Voltage Measurement... 13:10:26 Voltage Offset Correction: v_off_ini = 2543.681 uV, v_off_fin = 2547.858 uV 13:10:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 102.179 uVs 13:10:28 I2X Average and RMS of Measurements VT = -111.891 +- 5.264 uVs I2X = 10.294 +- 0.484 uTm^2 13:10:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:10:36 Integrated Voltage Measurement... 13:10:45 Voltage Offset Correction: v_off_ini = 2532.752 uV, v_off_fin = 2519.687 uV 13:10:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.277 uVs 13:10:45 Integrated Voltage Measurement... 13:10:54 Voltage Offset Correction: v_off_ini = 2520.388 uV, v_off_fin = 2518.012 uV 13:10:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.051 uVs 13:10:54 Integrated Voltage Measurement... 13:11:03 Voltage Offset Correction: v_off_ini = 2537.496 uV, v_off_fin = 2535.700 uV 13:11:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.594 uVs 13:11:03 Integrated Voltage Measurement... 13:11:12 Voltage Offset Correction: v_off_ini = 2530.960 uV, v_off_fin = 2557.480 uV 13:11:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.254 uVs 13:11:12 Integrated Voltage Measurement... 13:11:21 Voltage Offset Correction: v_off_ini = 2547.329 uV, v_off_fin = 2533.031 uV 13:11:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.295 uVs 13:11:21 Integrated Voltage Measurement... 13:11:30 Voltage Offset Correction: v_off_ini = 2536.611 uV, v_off_fin = 2544.157 uV 13:11:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.273 uVs 13:11:33 I2Y Average and RMS of Measurements VT = -259.291 +- 8.585 uVs I2Y = -23.855 +- 0.790 uTm^2 13:11:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:51 Integrated Voltage Measurement... 13:12:00 Voltage Offset Correction: v_off_ini = 2580.288 uV, v_off_fin = 2545.679 uV 13:12:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.367 uVs 13:12:00 Integrated Voltage Measurement... 13:12:09 Voltage Offset Correction: v_off_ini = 2551.671 uV, v_off_fin = 2567.856 uV 13:12:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.436 uVs 13:12:09 Integrated Voltage Measurement... 13:12:18 Voltage Offset Correction: v_off_ini = 2557.338 uV, v_off_fin = 2547.413 uV 13:12:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.522 uVs 13:12:18 Integrated Voltage Measurement... 13:12:27 Voltage Offset Correction: v_off_ini = 2553.398 uV, v_off_fin = 2543.542 uV 13:12:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.226 uVs 13:12:27 Integrated Voltage Measurement... 13:12:36 Voltage Offset Correction: v_off_ini = 2571.417 uV, v_off_fin = 2560.848 uV 13:12:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.492 uVs 13:12:36 Integrated Voltage Measurement... 13:12:45 Voltage Offset Correction: v_off_ini = 2577.927 uV, v_off_fin = 2570.751 uV 13:12:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.088 uVs 13:12:49 I1X Average and RMS of Measurements VT = -113.022 +- 13.778 uVs I1X = 22.604 +- 2.756 uTm 13:12:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:56 Integrated Voltage Measurement... 13:13:05 Voltage Offset Correction: v_off_ini = 2565.738 uV, v_off_fin = 2565.157 uV 13:13:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -220.197 uVs 13:13:05 Integrated Voltage Measurement... 13:13:14 Voltage Offset Correction: v_off_ini = 2577.458 uV, v_off_fin = 2585.748 uV 13:13:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.367 uVs 13:13:14 Integrated Voltage Measurement... 13:13:23 Voltage Offset Correction: v_off_ini = 2557.091 uV, v_off_fin = 2549.717 uV 13:13:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.946 uVs 13:13:23 Integrated Voltage Measurement... 13:13:32 Voltage Offset Correction: v_off_ini = 2543.467 uV, v_off_fin = 2580.095 uV 13:13:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.943 uVs 13:13:32 Integrated Voltage Measurement... 13:13:41 Voltage Offset Correction: v_off_ini = 2560.217 uV, v_off_fin = 2554.514 uV 13:13:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.887 uVs 13:13:41 Integrated Voltage Measurement... 13:13:50 Voltage Offset Correction: v_off_ini = 2568.654 uV, v_off_fin = 2581.433 uV 13:13:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.224 uVs 13:13:54 I1Y Average and RMS of Measurements VT = -205.094 +- 5.007 uVs I1Y = -41.020 +- 1.002 uTm 13:13:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:14:02 Integrated Voltage Measurement... 13:14:11 Voltage Offset Correction: v_off_ini = 2540.934 uV, v_off_fin = 2535.895 uV 13:14:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -108.567 uVs 13:14:11 Integrated Voltage Measurement... 13:14:20 Voltage Offset Correction: v_off_ini = 2543.598 uV, v_off_fin = 2566.398 uV 13:14:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.039 uVs 13:14:20 Integrated Voltage Measurement... 13:14:29 Voltage Offset Correction: v_off_ini = 2558.106 uV, v_off_fin = 2530.365 uV 13:14:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.769 uVs 13:14:29 Integrated Voltage Measurement... 13:14:38 Voltage Offset Correction: v_off_ini = 2568.201 uV, v_off_fin = 2581.109 uV 13:14:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.185 uVs 13:14:38 Integrated Voltage Measurement... 13:14:47 Voltage Offset Correction: v_off_ini = 2578.888 uV, v_off_fin = 2556.546 uV 13:14:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.467 uVs 13:14:47 Integrated Voltage Measurement... 13:14:56 Voltage Offset Correction: v_off_ini = 2580.620 uV, v_off_fin = 2603.874 uV 13:14:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 119.721 uVs 13:14:58 I2X Average and RMS of Measurements VT = -103.625 +- 4.214 uVs I2X = 9.533 +- 0.388 uTm^2 13:15:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:06 Integrated Voltage Measurement... 13:15:15 Voltage Offset Correction: v_off_ini = 2596.176 uV, v_off_fin = 2590.850 uV 13:15:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -269.688 uVs 13:15:15 Integrated Voltage Measurement... 13:15:24 Voltage Offset Correction: v_off_ini = 2585.896 uV, v_off_fin = 2591.217 uV 13:15:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 278.573 uVs 13:15:24 Integrated Voltage Measurement... 13:15:33 Voltage Offset Correction: v_off_ini = 2606.609 uV, v_off_fin = 2613.722 uV 13:15:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.712 uVs 13:15:33 Integrated Voltage Measurement... 13:15:42 Voltage Offset Correction: v_off_ini = 2627.315 uV, v_off_fin = 2614.773 uV 13:15:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.119 uVs 13:15:42 Integrated Voltage Measurement... 13:15:51 Voltage Offset Correction: v_off_ini = 2621.567 uV, v_off_fin = 2594.347 uV 13:15:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -273.854 uVs 13:15:51 Integrated Voltage Measurement... 13:16:00 Voltage Offset Correction: v_off_ini = 2590.100 uV, v_off_fin = 2611.300 uV 13:16:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.245 uVs 13:16:03 I2Y Average and RMS of Measurements VT = -275.198 +- 5.913 uVs I2Y = -25.319 +- 0.543 uTm^2 13:16:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:16:21 Integrated Voltage Measurement... 13:16:30 Voltage Offset Correction: v_off_ini = 2619.591 uV, v_off_fin = 2610.332 uV 13:16:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -104.728 uVs 13:16:30 Integrated Voltage Measurement... 13:16:39 Voltage Offset Correction: v_off_ini = 2636.987 uV, v_off_fin = 2615.097 uV 13:16:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.614 uVs 13:16:39 Integrated Voltage Measurement... 13:16:48 Voltage Offset Correction: v_off_ini = 2607.018 uV, v_off_fin = 2633.340 uV 13:16:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.470 uVs 13:16:48 Integrated Voltage Measurement... 13:16:57 Voltage Offset Correction: v_off_ini = 2626.774 uV, v_off_fin = 2623.223 uV 13:16:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.111 uVs 13:16:57 Integrated Voltage Measurement... 13:17:06 Voltage Offset Correction: v_off_ini = 2605.763 uV, v_off_fin = 2609.987 uV 13:17:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.123 uVs 13:17:06 Integrated Voltage Measurement... 13:17:15 Voltage Offset Correction: v_off_ini = 2576.478 uV, v_off_fin = 2621.795 uV 13:17:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.616 uVs 13:17:19 I1X Average and RMS of Measurements VT = -100.277 +- 5.947 uVs I1X = 20.056 +- 1.190 uTm 13:17:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:17:26 Integrated Voltage Measurement... 13:17:35 Voltage Offset Correction: v_off_ini = 2639.326 uV, v_off_fin = 2624.155 uV 13:17:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -174.838 uVs 13:17:35 Integrated Voltage Measurement... 13:17:44 Voltage Offset Correction: v_off_ini = 2630.666 uV, v_off_fin = 2626.595 uV 13:17:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 220.122 uVs 13:17:44 Integrated Voltage Measurement... 13:17:53 Voltage Offset Correction: v_off_ini = 2661.156 uV, v_off_fin = 2634.442 uV 13:17:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.869 uVs 13:17:53 Integrated Voltage Measurement... 13:18:02 Voltage Offset Correction: v_off_ini = 2626.510 uV, v_off_fin = 2635.178 uV 13:18:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.543 uVs 13:18:02 Integrated Voltage Measurement... 13:18:11 Voltage Offset Correction: v_off_ini = 2631.745 uV, v_off_fin = 2603.754 uV 13:18:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.987 uVs 13:18:11 Integrated Voltage Measurement... 13:18:20 Voltage Offset Correction: v_off_ini = 2609.659 uV, v_off_fin = 2622.636 uV 13:18:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 208.433 uVs 13:18:24 I1Y Average and RMS of Measurements VT = -203.965 +- 4.867 uVs I1Y = -40.790 +- 0.973 uTm 13:18:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:18:32 Integrated Voltage Measurement... 13:18:41 Voltage Offset Correction: v_off_ini = 2613.664 uV, v_off_fin = 2612.447 uV 13:18:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -116.377 uVs 13:18:41 Integrated Voltage Measurement... 13:18:50 Voltage Offset Correction: v_off_ini = 2634.713 uV, v_off_fin = 2614.631 uV 13:18:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.976 uVs 13:18:50 Integrated Voltage Measurement... 13:18:59 Voltage Offset Correction: v_off_ini = 2641.087 uV, v_off_fin = 2631.992 uV 13:18:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -124.105 uVs 13:18:59 Integrated Voltage Measurement... 13:19:08 Voltage Offset Correction: v_off_ini = 2616.081 uV, v_off_fin = 2612.683 uV 13:19:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.512 uVs 13:19:08 Integrated Voltage Measurement... 13:19:17 Voltage Offset Correction: v_off_ini = 2612.680 uV, v_off_fin = 2612.131 uV 13:19:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.270 uVs 13:19:17 Integrated Voltage Measurement... 13:19:26 Voltage Offset Correction: v_off_ini = 2624.977 uV, v_off_fin = 2627.160 uV 13:19:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 123.016 uVs 13:19:28 I2X Average and RMS of Measurements VT = -116.376 +- 2.779 uVs I2X = 10.706 +- 0.256 uTm^2 13:19:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:19:36 Integrated Voltage Measurement... 13:19:45 Voltage Offset Correction: v_off_ini = 2588.882 uV, v_off_fin = 2603.584 uV 13:19:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.471 uVs 13:19:45 Integrated Voltage Measurement... 13:19:54 Voltage Offset Correction: v_off_ini = 2586.790 uV, v_off_fin = 2582.662 uV 13:19:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.954 uVs 13:19:54 Integrated Voltage Measurement... 13:20:03 Voltage Offset Correction: v_off_ini = 2602.358 uV, v_off_fin = 2607.163 uV 13:20:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.389 uVs 13:20:03 Integrated Voltage Measurement... 13:20:12 Voltage Offset Correction: v_off_ini = 2591.512 uV, v_off_fin = 2596.039 uV 13:20:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 253.140 uVs 13:20:12 Integrated Voltage Measurement... 13:20:21 Voltage Offset Correction: v_off_ini = 2574.882 uV, v_off_fin = 2561.545 uV 13:20:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.504 uVs 13:20:21 Integrated Voltage Measurement... 13:20:30 Voltage Offset Correction: v_off_ini = 2575.525 uV, v_off_fin = 2565.271 uV 13:20:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.368 uVs 13:20:33 I2Y Average and RMS of Measurements VT = -260.138 +- 2.437 uVs I2Y = -23.933 +- 0.224 uTm^2 13:20:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm