SLAC Magnetic Measurements Date: 07-16-2026 Time: 12:01:21 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_16335 Dataset Number: 1 Run Purpose: Final Results Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 12:01:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:01:31 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:01:33 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:01:34 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:01:36 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 12:02:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:02:26 Integrated Voltage Measurement... 12:02:35 Voltage Offset Correction: v_off_ini = 2593.003 uV, v_off_fin = 2596.077 uV 12:02:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -82.893 uVs 12:02:35 Integrated Voltage Measurement... 12:02:44 Voltage Offset Correction: v_off_ini = 2586.976 uV, v_off_fin = 2572.466 uV 12:02:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.764 uVs 12:02:44 Integrated Voltage Measurement... 12:02:53 Voltage Offset Correction: v_off_ini = 2577.593 uV, v_off_fin = 2592.223 uV 12:02:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.017 uVs 12:02:53 Integrated Voltage Measurement... 12:03:02 Voltage Offset Correction: v_off_ini = 2573.752 uV, v_off_fin = 2561.622 uV 12:03:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 78.386 uVs 12:03:02 Integrated Voltage Measurement... 12:03:11 Voltage Offset Correction: v_off_ini = 2582.324 uV, v_off_fin = 2584.446 uV 12:03:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.205 uVs 12:03:11 Integrated Voltage Measurement... 12:03:20 Voltage Offset Correction: v_off_ini = 2589.575 uV, v_off_fin = 2593.053 uV 12:03:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.831 uVs 12:03:24 I1X Average and RMS of Measurements VT = -75.349 +- 5.310 uVs I1X = 15.071 +- 1.062 uTm 12:03:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:03:31 Integrated Voltage Measurement... 12:03:40 Voltage Offset Correction: v_off_ini = 2615.631 uV, v_off_fin = 2581.041 uV 12:03:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.057 uVs 12:03:40 Integrated Voltage Measurement... 12:03:49 Voltage Offset Correction: v_off_ini = 2619.626 uV, v_off_fin = 2643.204 uV 12:03:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.970 uVs 12:03:49 Integrated Voltage Measurement... 12:03:58 Voltage Offset Correction: v_off_ini = 2643.013 uV, v_off_fin = 2642.230 uV 12:03:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.473 uVs 12:03:58 Integrated Voltage Measurement... 12:04:07 Voltage Offset Correction: v_off_ini = 2638.843 uV, v_off_fin = 2658.629 uV 12:04:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.918 uVs 12:04:07 Integrated Voltage Measurement... 12:04:16 Voltage Offset Correction: v_off_ini = 2605.237 uV, v_off_fin = 2600.269 uV 12:04:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.562 uVs 12:04:16 Integrated Voltage Measurement... 12:04:25 Voltage Offset Correction: v_off_ini = 2590.180 uV, v_off_fin = 2609.747 uV 12:04:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.712 uVs 12:04:29 I1Y Average and RMS of Measurements VT = -242.782 +- 3.012 uVs I1Y = -48.556 +- 0.602 uTm 12:04:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:04:37 Integrated Voltage Measurement... 12:04:46 Voltage Offset Correction: v_off_ini = 2608.895 uV, v_off_fin = 2601.321 uV 12:04:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -30.837 uVs 12:04:46 Integrated Voltage Measurement... 12:04:55 Voltage Offset Correction: v_off_ini = 2612.914 uV, v_off_fin = 2618.247 uV 12:04:55 Integrated Voltage Measurement dXYus = 0.9998 mm, dXYds = 0.0000 mm dXY = 0.9998 mm VT = 5.860 uVs 12:04:55 Integrated Voltage Measurement... 12:05:04 Voltage Offset Correction: v_off_ini = 2610.254 uV, v_off_fin = 2603.438 uV 12:05:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -24.612 uVs 12:05:04 Integrated Voltage Measurement... 12:05:13 Voltage Offset Correction: v_off_ini = 2598.889 uV, v_off_fin = 2638.089 uV 12:05:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -8.811 uVs 12:05:13 Integrated Voltage Measurement... 12:05:22 Voltage Offset Correction: v_off_ini = 2618.871 uV, v_off_fin = 2594.473 uV 12:05:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.939 uVs 12:05:22 Integrated Voltage Measurement... 12:05:31 Voltage Offset Correction: v_off_ini = 2611.047 uV, v_off_fin = 2620.882 uV 12:05:31 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 24.065 uVs 12:05:33 I2X Average and RMS of Measurements VT = -18.250 +- 8.411 uVs I2X = 1.679 +- 0.774 uTm^2 12:05:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:05:41 Integrated Voltage Measurement... 12:05:50 Voltage Offset Correction: v_off_ini = 2598.887 uV, v_off_fin = 2591.883 uV 12:05:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -252.852 uVs 12:05:50 Integrated Voltage Measurement... 12:05:59 Voltage Offset Correction: v_off_ini = 2626.688 uV, v_off_fin = 2610.502 uV 12:05:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.503 uVs 12:05:59 Integrated Voltage Measurement... 12:06:08 Voltage Offset Correction: v_off_ini = 2603.537 uV, v_off_fin = 2600.694 uV 12:06:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.358 uVs 12:06:08 Integrated Voltage Measurement... 12:06:17 Voltage Offset Correction: v_off_ini = 2620.484 uV, v_off_fin = 2621.948 uV 12:06:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.304 uVs 12:06:17 Integrated Voltage Measurement... 12:06:26 Voltage Offset Correction: v_off_ini = 2621.857 uV, v_off_fin = 2638.041 uV 12:06:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.457 uVs 12:06:26 Integrated Voltage Measurement... 12:06:35 Voltage Offset Correction: v_off_ini = 2625.101 uV, v_off_fin = 2611.950 uV 12:06:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.712 uVs 12:06:37 I2Y Average and RMS of Measurements VT = -252.198 +- 3.461 uVs I2Y = -23.203 +- 0.318 uTm^2 12:06:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:06:46 Integrated Voltage Measurement... 12:06:55 Voltage Offset Correction: v_off_ini = 2630.774 uV, v_off_fin = 2634.398 uV 12:06:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.070 uVs 12:06:55 Integrated Voltage Measurement... 12:07:04 Voltage Offset Correction: v_off_ini = 2623.992 uV, v_off_fin = 2651.741 uV 12:07:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.347 uVs 12:07:04 Integrated Voltage Measurement... 12:07:13 Voltage Offset Correction: v_off_ini = 2628.912 uV, v_off_fin = 2636.229 uV 12:07:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.932 uVs 12:07:13 Integrated Voltage Measurement... 12:07:22 Voltage Offset Correction: v_off_ini = 2656.247 uV, v_off_fin = 2652.721 uV 12:07:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.846 uVs 12:07:22 Integrated Voltage Measurement... 12:07:31 Voltage Offset Correction: v_off_ini = 2639.106 uV, v_off_fin = 2642.726 uV 12:07:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.149 uVs 12:07:31 Integrated Voltage Measurement... 12:07:40 Voltage Offset Correction: v_off_ini = 2630.413 uV, v_off_fin = 2639.738 uV 12:07:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.177 uVs 12:07:44 I1X Average and RMS of Measurements VT = -83.587 +- 6.107 uVs I1X = 16.718 +- 1.221 uTm 12:07:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:07:51 Integrated Voltage Measurement... 12:08:00 Voltage Offset Correction: v_off_ini = 2620.440 uV, v_off_fin = 2620.113 uV 12:08:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.835 uVs 12:08:00 Integrated Voltage Measurement... 12:08:09 Voltage Offset Correction: v_off_ini = 2625.426 uV, v_off_fin = 2634.313 uV 12:08:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.752 uVs 12:08:09 Integrated Voltage Measurement... 12:08:18 Voltage Offset Correction: v_off_ini = 2599.123 uV, v_off_fin = 2602.253 uV 12:08:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.677 uVs 12:08:18 Integrated Voltage Measurement... 12:08:27 Voltage Offset Correction: v_off_ini = 2619.950 uV, v_off_fin = 2627.500 uV 12:08:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.041 uVs 12:08:27 Integrated Voltage Measurement... 12:08:36 Voltage Offset Correction: v_off_ini = 2623.956 uV, v_off_fin = 2605.536 uV 12:08:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.720 uVs 12:08:36 Integrated Voltage Measurement... 12:08:45 Voltage Offset Correction: v_off_ini = 2657.718 uV, v_off_fin = 2671.915 uV 12:08:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.971 uVs 12:08:49 I1Y Average and RMS of Measurements VT = -258.833 +- 7.357 uVs I1Y = -51.767 +- 1.471 uTm 12:08:54 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:08:57 Integrated Voltage Measurement... 12:09:06 Voltage Offset Correction: v_off_ini = 2633.939 uV, v_off_fin = 2629.662 uV 12:09:06 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -29.341 uVs 12:09:06 Integrated Voltage Measurement... 12:09:15 Voltage Offset Correction: v_off_ini = 2649.303 uV, v_off_fin = 2640.614 uV 12:09:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 17.023 uVs 12:09:15 Integrated Voltage Measurement... 12:09:24 Voltage Offset Correction: v_off_ini = 2644.694 uV, v_off_fin = 2639.618 uV 12:09:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.296 uVs 12:09:24 Integrated Voltage Measurement... 12:09:33 Voltage Offset Correction: v_off_ini = 2650.458 uV, v_off_fin = 2655.923 uV 12:09:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 1.272 uVs 12:09:33 Integrated Voltage Measurement... 12:09:42 Voltage Offset Correction: v_off_ini = 2654.587 uV, v_off_fin = 2617.816 uV 12:09:42 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -13.591 uVs 12:09:42 Integrated Voltage Measurement... 12:09:51 Voltage Offset Correction: v_off_ini = 2639.982 uV, v_off_fin = 2660.891 uV 12:09:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -11.753 uVs 12:09:53 I2X Average and RMS of Measurements VT = -8.295 +- 10.527 uVs I2X = 0.763 +- 0.968 uTm^2 12:09:58 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:10:01 Integrated Voltage Measurement... 12:10:10 Voltage Offset Correction: v_off_ini = 2641.449 uV, v_off_fin = 2646.913 uV 12:10:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.159 uVs 12:10:10 Integrated Voltage Measurement... 12:10:19 Voltage Offset Correction: v_off_ini = 2643.615 uV, v_off_fin = 2644.013 uV 12:10:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.201 uVs 12:10:19 Integrated Voltage Measurement... 12:10:28 Voltage Offset Correction: v_off_ini = 2649.418 uV, v_off_fin = 2645.090 uV 12:10:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.078 uVs 12:10:28 Integrated Voltage Measurement... 12:10:37 Voltage Offset Correction: v_off_ini = 2660.580 uV, v_off_fin = 2663.797 uV 12:10:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.635 uVs 12:10:37 Integrated Voltage Measurement... 12:10:46 Voltage Offset Correction: v_off_ini = 2670.668 uV, v_off_fin = 2656.625 uV 12:10:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.921 uVs 12:10:46 Integrated Voltage Measurement... 12:10:55 Voltage Offset Correction: v_off_ini = 2634.218 uV, v_off_fin = 2634.647 uV 12:10:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.514 uVs 12:10:57 I2Y Average and RMS of Measurements VT = -270.418 +- 8.185 uVs I2Y = -24.878 +- 0.753 uTm^2 12:11:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:11:06 Integrated Voltage Measurement... 12:11:15 Voltage Offset Correction: v_off_ini = 2643.265 uV, v_off_fin = 2618.073 uV 12:11:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.986 uVs 12:11:15 Integrated Voltage Measurement... 12:11:24 Voltage Offset Correction: v_off_ini = 2618.630 uV, v_off_fin = 2622.897 uV 12:11:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.659 uVs 12:11:24 Integrated Voltage Measurement... 12:11:33 Voltage Offset Correction: v_off_ini = 2607.531 uV, v_off_fin = 2630.344 uV 12:11:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.314 uVs 12:11:33 Integrated Voltage Measurement... 12:11:42 Voltage Offset Correction: v_off_ini = 2634.575 uV, v_off_fin = 2632.182 uV 12:11:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.170 uVs 12:11:42 Integrated Voltage Measurement... 12:11:51 Voltage Offset Correction: v_off_ini = 2641.677 uV, v_off_fin = 2630.050 uV 12:11:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.518 uVs 12:11:51 Integrated Voltage Measurement... 12:12:00 Voltage Offset Correction: v_off_ini = 2652.767 uV, v_off_fin = 2638.449 uV 12:12:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.481 uVs 12:12:04 I1X Average and RMS of Measurements VT = -87.354 +- 12.197 uVs I1X = 17.471 +- 2.439 uTm 12:12:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:12:11 Integrated Voltage Measurement... 12:12:20 Voltage Offset Correction: v_off_ini = 2623.238 uV, v_off_fin = 2595.152 uV 12:12:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.015 uVs 12:12:20 Integrated Voltage Measurement... 12:12:29 Voltage Offset Correction: v_off_ini = 2654.515 uV, v_off_fin = 2641.894 uV 12:12:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.558 uVs 12:12:29 Integrated Voltage Measurement... 12:12:38 Voltage Offset Correction: v_off_ini = 2640.723 uV, v_off_fin = 2631.685 uV 12:12:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.942 uVs 12:12:38 Integrated Voltage Measurement... 12:12:47 Voltage Offset Correction: v_off_ini = 2631.604 uV, v_off_fin = 2645.912 uV 12:12:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.032 uVs 12:12:47 Integrated Voltage Measurement... 12:12:56 Voltage Offset Correction: v_off_ini = 2655.245 uV, v_off_fin = 2636.160 uV 12:12:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -289.136 uVs 12:12:56 Integrated Voltage Measurement... 12:13:05 Voltage Offset Correction: v_off_ini = 2627.579 uV, v_off_fin = 2630.526 uV 12:13:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.246 uVs 12:13:09 I1Y Average and RMS of Measurements VT = -265.988 +- 11.733 uVs I1Y = -53.198 +- 2.347 uTm 12:13:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:13:17 Integrated Voltage Measurement... 12:13:26 Voltage Offset Correction: v_off_ini = 2633.578 uV, v_off_fin = 2636.694 uV 12:13:26 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -3.019 uVs 12:13:26 Integrated Voltage Measurement... 12:13:35 Voltage Offset Correction: v_off_ini = 2656.021 uV, v_off_fin = 2670.356 uV 12:13:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.927 uVs 12:13:35 Integrated Voltage Measurement... 12:13:44 Voltage Offset Correction: v_off_ini = 2656.669 uV, v_off_fin = 2641.936 uV 12:13:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.529 uVs 12:13:44 Integrated Voltage Measurement... 12:13:53 Voltage Offset Correction: v_off_ini = 2624.298 uV, v_off_fin = 2638.138 uV 12:13:53 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 29.188 uVs 12:13:53 Integrated Voltage Measurement... 12:14:02 Voltage Offset Correction: v_off_ini = 2639.239 uV, v_off_fin = 2612.306 uV 12:14:02 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -23.984 uVs 12:14:02 Integrated Voltage Measurement... 12:14:11 Voltage Offset Correction: v_off_ini = 2624.251 uV, v_off_fin = 2635.133 uV 12:14:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -6.998 uVs 12:14:13 I2X Average and RMS of Measurements VT = -17.441 +- 12.669 uVs I2X = 1.605 +- 1.166 uTm^2 12:14:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:14:21 Integrated Voltage Measurement... 12:14:30 Voltage Offset Correction: v_off_ini = 2610.525 uV, v_off_fin = 2612.174 uV 12:14:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.269 uVs 12:14:30 Integrated Voltage Measurement... 12:14:39 Voltage Offset Correction: v_off_ini = 2602.898 uV, v_off_fin = 2606.805 uV 12:14:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.312 uVs 12:14:39 Integrated Voltage Measurement... 12:14:48 Voltage Offset Correction: v_off_ini = 2612.019 uV, v_off_fin = 2617.688 uV 12:14:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -295.771 uVs 12:14:48 Integrated Voltage Measurement... 12:14:57 Voltage Offset Correction: v_off_ini = 2621.272 uV, v_off_fin = 2620.657 uV 12:14:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.618 uVs 12:14:57 Integrated Voltage Measurement... 12:15:06 Voltage Offset Correction: v_off_ini = 2635.909 uV, v_off_fin = 2627.578 uV 12:15:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.416 uVs 12:15:06 Integrated Voltage Measurement... 12:15:15 Voltage Offset Correction: v_off_ini = 2657.526 uV, v_off_fin = 2637.928 uV 12:15:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.640 uVs 12:15:17 I2Y Average and RMS of Measurements VT = -281.004 +- 15.337 uVs I2Y = -25.852 +- 1.411 uTm^2 12:15:22 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:15:26 Integrated Voltage Measurement... 12:15:35 Voltage Offset Correction: v_off_ini = 2663.195 uV, v_off_fin = 2637.911 uV 12:15:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.889 uVs 12:15:35 Integrated Voltage Measurement... 12:15:44 Voltage Offset Correction: v_off_ini = 2623.705 uV, v_off_fin = 2640.896 uV 12:15:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.268 uVs 12:15:44 Integrated Voltage Measurement... 12:15:53 Voltage Offset Correction: v_off_ini = 2647.748 uV, v_off_fin = 2627.217 uV 12:15:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.944 uVs 12:15:53 Integrated Voltage Measurement... 12:16:02 Voltage Offset Correction: v_off_ini = 2642.739 uV, v_off_fin = 2631.676 uV 12:16:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.569 uVs 12:16:02 Integrated Voltage Measurement... 12:16:11 Voltage Offset Correction: v_off_ini = 2660.050 uV, v_off_fin = 2663.979 uV 12:16:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.122 uVs 12:16:11 Integrated Voltage Measurement... 12:16:20 Voltage Offset Correction: v_off_ini = 2665.644 uV, v_off_fin = 2659.528 uV 12:16:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.867 uVs 12:16:24 I1X Average and RMS of Measurements VT = -101.776 +- 7.585 uVs I1X = 20.355 +- 1.517 uTm 12:16:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:16:31 Integrated Voltage Measurement... 12:16:40 Voltage Offset Correction: v_off_ini = 2671.117 uV, v_off_fin = 2661.582 uV 12:16:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -295.234 uVs 12:16:40 Integrated Voltage Measurement... 12:16:49 Voltage Offset Correction: v_off_ini = 2681.481 uV, v_off_fin = 2660.743 uV 12:16:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 292.118 uVs 12:16:49 Integrated Voltage Measurement... 12:16:58 Voltage Offset Correction: v_off_ini = 2659.239 uV, v_off_fin = 2666.753 uV 12:16:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.457 uVs 12:16:58 Integrated Voltage Measurement... 12:17:07 Voltage Offset Correction: v_off_ini = 2677.752 uV, v_off_fin = 2702.321 uV 12:17:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.874 uVs 12:17:07 Integrated Voltage Measurement... 12:17:16 Voltage Offset Correction: v_off_ini = 2679.308 uV, v_off_fin = 2671.232 uV 12:17:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.267 uVs 12:17:16 Integrated Voltage Measurement... 12:17:25 Voltage Offset Correction: v_off_ini = 2677.569 uV, v_off_fin = 2672.630 uV 12:17:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 255.946 uVs 12:17:29 I1Y Average and RMS of Measurements VT = -284.983 +- 11.935 uVs I1Y = -56.997 +- 2.388 uTm 12:17:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:17:37 Integrated Voltage Measurement... 12:17:46 Voltage Offset Correction: v_off_ini = 2655.139 uV, v_off_fin = 2669.249 uV 12:17:46 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -39.251 uVs 12:17:46 Integrated Voltage Measurement... 12:17:55 Voltage Offset Correction: v_off_ini = 2666.253 uV, v_off_fin = 2667.453 uV 12:17:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 50.490 uVs 12:17:55 Integrated Voltage Measurement... 12:18:04 Voltage Offset Correction: v_off_ini = 2643.813 uV, v_off_fin = 2612.162 uV 12:18:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -7.904 uVs 12:18:04 Integrated Voltage Measurement... 12:18:13 Voltage Offset Correction: v_off_ini = 2643.148 uV, v_off_fin = 2645.529 uV 12:18:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.993 uVs 12:18:13 Integrated Voltage Measurement... 12:18:22 Voltage Offset Correction: v_off_ini = 2633.031 uV, v_off_fin = 2635.756 uV 12:18:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.447 uVs 12:18:22 Integrated Voltage Measurement... 12:18:31 Voltage Offset Correction: v_off_ini = 2637.266 uV, v_off_fin = 2661.110 uV 12:18:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.750 uVs 12:18:33 I2X Average and RMS of Measurements VT = -39.306 +- 11.762 uVs I2X = 3.616 +- 1.082 uTm^2 12:18:38 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:18:41 Integrated Voltage Measurement... 12:18:50 Voltage Offset Correction: v_off_ini = 2676.922 uV, v_off_fin = 2677.087 uV 12:18:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.840 uVs 12:18:50 Integrated Voltage Measurement... 12:18:59 Voltage Offset Correction: v_off_ini = 2670.442 uV, v_off_fin = 2666.914 uV 12:18:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.387 uVs 12:18:59 Integrated Voltage Measurement... 12:19:08 Voltage Offset Correction: v_off_ini = 2665.919 uV, v_off_fin = 2660.218 uV 12:19:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.030 uVs 12:19:08 Integrated Voltage Measurement... 12:19:17 Voltage Offset Correction: v_off_ini = 2652.083 uV, v_off_fin = 2656.871 uV 12:19:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.962 uVs 12:19:17 Integrated Voltage Measurement... 12:19:26 Voltage Offset Correction: v_off_ini = 2666.670 uV, v_off_fin = 2660.063 uV 12:19:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.071 uVs 12:19:26 Integrated Voltage Measurement... 12:19:35 Voltage Offset Correction: v_off_ini = 2663.469 uV, v_off_fin = 2675.925 uV 12:19:35 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 295.090 uVs 12:19:37 I2Y Average and RMS of Measurements VT = -303.063 +- 3.238 uVs I2Y = -27.882 +- 0.297 uTm^2 12:19:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:19:46 Integrated Voltage Measurement... 12:19:55 Voltage Offset Correction: v_off_ini = 2689.085 uV, v_off_fin = 2687.357 uV 12:19:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.423 uVs 12:19:55 Integrated Voltage Measurement... 12:20:04 Voltage Offset Correction: v_off_ini = 2672.921 uV, v_off_fin = 2688.757 uV 12:20:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 118.272 uVs 12:20:04 Integrated Voltage Measurement... 12:20:13 Voltage Offset Correction: v_off_ini = 2670.271 uV, v_off_fin = 2681.969 uV 12:20:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.846 uVs 12:20:13 Integrated Voltage Measurement... 12:20:22 Voltage Offset Correction: v_off_ini = 2690.540 uV, v_off_fin = 2673.149 uV 12:20:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.918 uVs 12:20:22 Integrated Voltage Measurement... 12:20:31 Voltage Offset Correction: v_off_ini = 2685.364 uV, v_off_fin = 2684.561 uV 12:20:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.559 uVs 12:20:31 Integrated Voltage Measurement... 12:20:40 Voltage Offset Correction: v_off_ini = 2680.815 uV, v_off_fin = 2661.446 uV 12:20:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 160.452 uVs 12:20:45 I1X Average and RMS of Measurements VT = -132.912 +- 7.837 uVs I1X = 26.583 +- 1.566 uTm 12:20:47 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:20:51 Integrated Voltage Measurement... 12:21:00 Voltage Offset Correction: v_off_ini = 2657.918 uV, v_off_fin = 2640.752 uV 12:21:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -311.049 uVs 12:21:00 Integrated Voltage Measurement... 12:21:09 Voltage Offset Correction: v_off_ini = 2657.886 uV, v_off_fin = 2661.347 uV 12:21:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 288.704 uVs 12:21:09 Integrated Voltage Measurement... 12:21:18 Voltage Offset Correction: v_off_ini = 2650.064 uV, v_off_fin = 2635.420 uV 12:21:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -293.766 uVs 12:21:18 Integrated Voltage Measurement... 12:21:27 Voltage Offset Correction: v_off_ini = 2634.485 uV, v_off_fin = 2670.182 uV 12:21:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.614 uVs 12:21:27 Integrated Voltage Measurement... 12:21:36 Voltage Offset Correction: v_off_ini = 2655.261 uV, v_off_fin = 2631.564 uV 12:21:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.134 uVs 12:21:36 Integrated Voltage Measurement... 12:21:45 Voltage Offset Correction: v_off_ini = 2655.595 uV, v_off_fin = 2669.671 uV 12:21:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.259 uVs 12:21:49 I1Y Average and RMS of Measurements VT = -290.421 +- 8.287 uVs I1Y = -58.084 +- 1.657 uTm 12:21:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:21:57 Integrated Voltage Measurement... 12:22:06 Voltage Offset Correction: v_off_ini = 2655.754 uV, v_off_fin = 2632.475 uV 12:22:06 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -64.778 uVs 12:22:06 Integrated Voltage Measurement... 12:22:15 Voltage Offset Correction: v_off_ini = 2637.458 uV, v_off_fin = 2659.629 uV 12:22:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.228 uVs 12:22:15 Integrated Voltage Measurement... 12:22:24 Voltage Offset Correction: v_off_ini = 2651.597 uV, v_off_fin = 2666.087 uV 12:22:24 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -37.575 uVs 12:22:24 Integrated Voltage Measurement... 12:22:33 Voltage Offset Correction: v_off_ini = 2651.934 uV, v_off_fin = 2659.340 uV 12:22:33 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 34.106 uVs 12:22:33 Integrated Voltage Measurement... 12:22:42 Voltage Offset Correction: v_off_ini = 2660.374 uV, v_off_fin = 2652.229 uV 12:22:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.708 uVs 12:22:42 Integrated Voltage Measurement... 12:22:51 Voltage Offset Correction: v_off_ini = 2652.374 uV, v_off_fin = 2663.492 uV 12:22:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 40.169 uVs 12:22:54 I2X Average and RMS of Measurements VT = -47.427 +- 10.623 uVs I2X = 4.363 +- 0.977 uTm^2 12:22:59 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:23:01 Integrated Voltage Measurement... 12:23:10 Voltage Offset Correction: v_off_ini = 2669.861 uV, v_off_fin = 2679.073 uV 12:23:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.790 uVs 12:23:10 Integrated Voltage Measurement... 12:23:19 Voltage Offset Correction: v_off_ini = 2697.658 uV, v_off_fin = 2686.146 uV 12:23:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.825 uVs 12:23:19 Integrated Voltage Measurement... 12:23:28 Voltage Offset Correction: v_off_ini = 2680.430 uV, v_off_fin = 2666.963 uV 12:23:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.295 uVs 12:23:28 Integrated Voltage Measurement... 12:23:37 Voltage Offset Correction: v_off_ini = 2677.318 uV, v_off_fin = 2650.760 uV 12:23:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.620 uVs 12:23:37 Integrated Voltage Measurement... 12:23:46 Voltage Offset Correction: v_off_ini = 2631.295 uV, v_off_fin = 2654.562 uV 12:23:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.083 uVs 12:23:46 Integrated Voltage Measurement... 12:23:55 Voltage Offset Correction: v_off_ini = 2642.957 uV, v_off_fin = 2630.017 uV 12:23:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.098 uVs 12:23:58 I2Y Average and RMS of Measurements VT = -303.452 +- 9.207 uVs I2Y = -27.918 +- 0.847 uTm^2 12:24:05 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:24:10 Integrated Voltage Measurement... 12:24:19 Voltage Offset Correction: v_off_ini = 2646.477 uV, v_off_fin = 2651.564 uV 12:24:19 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -72.209 uVs 12:24:19 Integrated Voltage Measurement... 12:24:28 Voltage Offset Correction: v_off_ini = 2651.094 uV, v_off_fin = 2646.652 uV 12:24:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.088 uVs 12:24:28 Integrated Voltage Measurement... 12:24:37 Voltage Offset Correction: v_off_ini = 2618.594 uV, v_off_fin = 2636.189 uV 12:24:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.311 uVs 12:24:37 Integrated Voltage Measurement... 12:24:46 Voltage Offset Correction: v_off_ini = 2638.683 uV, v_off_fin = 2672.755 uV 12:24:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.770 uVs 12:24:46 Integrated Voltage Measurement... 12:24:55 Voltage Offset Correction: v_off_ini = 2659.366 uV, v_off_fin = 2652.236 uV 12:24:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -85.932 uVs 12:24:55 Integrated Voltage Measurement... 12:25:04 Voltage Offset Correction: v_off_ini = 2657.252 uV, v_off_fin = 2651.166 uV 12:25:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.258 uVs 12:25:08 I1X Average and RMS of Measurements VT = -80.761 +- 6.596 uVs I1X = 16.153 +- 1.320 uTm 12:25:10 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:25:15 Integrated Voltage Measurement... 12:25:24 Voltage Offset Correction: v_off_ini = 2671.422 uV, v_off_fin = 2659.405 uV 12:25:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.924 uVs 12:25:24 Integrated Voltage Measurement... 12:25:33 Voltage Offset Correction: v_off_ini = 2683.741 uV, v_off_fin = 2673.248 uV 12:25:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.721 uVs 12:25:33 Integrated Voltage Measurement... 12:25:42 Voltage Offset Correction: v_off_ini = 2663.831 uV, v_off_fin = 2635.441 uV 12:25:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.580 uVs 12:25:42 Integrated Voltage Measurement... 12:25:51 Voltage Offset Correction: v_off_ini = 2679.076 uV, v_off_fin = 2693.250 uV 12:25:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.641 uVs 12:25:51 Integrated Voltage Measurement... 12:26:00 Voltage Offset Correction: v_off_ini = 2689.034 uV, v_off_fin = 2662.534 uV 12:26:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.434 uVs 12:26:00 Integrated Voltage Measurement... 12:26:09 Voltage Offset Correction: v_off_ini = 2662.029 uV, v_off_fin = 2663.802 uV 12:26:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.985 uVs 12:26:13 I1Y Average and RMS of Measurements VT = -253.048 +- 3.390 uVs I1Y = -50.610 +- 0.678 uTm 12:26:15 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:26:18 Integrated Voltage Measurement... 12:26:27 Voltage Offset Correction: v_off_ini = 2647.636 uV, v_off_fin = 2657.848 uV 12:26:27 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -51.956 uVs 12:26:27 Integrated Voltage Measurement... 12:26:36 Voltage Offset Correction: v_off_ini = 2658.818 uV, v_off_fin = 2668.057 uV 12:26:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.120 uVs 12:26:36 Integrated Voltage Measurement... 12:26:45 Voltage Offset Correction: v_off_ini = 2672.757 uV, v_off_fin = 2661.764 uV 12:26:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.636 uVs 12:26:45 Integrated Voltage Measurement... 12:26:54 Voltage Offset Correction: v_off_ini = 2672.665 uV, v_off_fin = 2689.083 uV 12:26:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 55.450 uVs 12:26:54 Integrated Voltage Measurement... 12:27:03 Voltage Offset Correction: v_off_ini = 2683.077 uV, v_off_fin = 2666.059 uV 12:27:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.289 uVs 12:27:03 Integrated Voltage Measurement... 12:27:12 Voltage Offset Correction: v_off_ini = 2678.923 uV, v_off_fin = 2681.818 uV 12:27:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.637 uVs 12:27:15 I2X Average and RMS of Measurements VT = -47.348 +- 8.602 uVs I2X = 4.356 +- 0.791 uTm^2 12:27:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:27:20 Integrated Voltage Measurement... 12:27:29 Voltage Offset Correction: v_off_ini = 2723.741 uV, v_off_fin = 2715.659 uV 12:27:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.336 uVs 12:27:29 Integrated Voltage Measurement... 12:27:38 Voltage Offset Correction: v_off_ini = 2693.672 uV, v_off_fin = 2689.375 uV 12:27:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.692 uVs 12:27:38 Integrated Voltage Measurement... 12:27:47 Voltage Offset Correction: v_off_ini = 2682.103 uV, v_off_fin = 2695.864 uV 12:27:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.721 uVs 12:27:47 Integrated Voltage Measurement... 12:27:56 Voltage Offset Correction: v_off_ini = 2716.930 uV, v_off_fin = 2727.186 uV 12:27:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.424 uVs 12:27:56 Integrated Voltage Measurement... 12:28:05 Voltage Offset Correction: v_off_ini = 2720.594 uV, v_off_fin = 2703.789 uV 12:28:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.757 uVs 12:28:05 Integrated Voltage Measurement... 12:28:14 Voltage Offset Correction: v_off_ini = 2712.558 uV, v_off_fin = 2724.960 uV 12:28:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 283.292 uVs 12:28:16 I2Y Average and RMS of Measurements VT = -280.537 +- 3.932 uVs I2Y = -25.809 +- 0.362 uTm^2 12:28:20 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:28:25 Integrated Voltage Measurement... 12:28:33 Voltage Offset Correction: v_off_ini = 2747.932 uV, v_off_fin = 2714.625 uV 12:28:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -93.661 uVs 12:28:34 Integrated Voltage Measurement... 12:28:42 Voltage Offset Correction: v_off_ini = 2741.568 uV, v_off_fin = 2748.050 uV 12:28:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.878 uVs 12:28:43 Integrated Voltage Measurement... 12:28:52 Voltage Offset Correction: v_off_ini = 2729.882 uV, v_off_fin = 2721.298 uV 12:28:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -85.740 uVs 12:28:52 Integrated Voltage Measurement... 12:29:01 Voltage Offset Correction: v_off_ini = 2736.486 uV, v_off_fin = 2736.176 uV 12:29:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.197 uVs 12:29:01 Integrated Voltage Measurement... 12:29:10 Voltage Offset Correction: v_off_ini = 2738.920 uV, v_off_fin = 2718.112 uV 12:29:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.023 uVs 12:29:10 Integrated Voltage Measurement... 12:29:19 Voltage Offset Correction: v_off_ini = 2737.513 uV, v_off_fin = 2740.901 uV 12:29:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.438 uVs 12:29:23 I1X Average and RMS of Measurements VT = -86.656 +- 7.864 uVs I1X = 17.332 +- 1.573 uTm 12:29:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:29:30 Integrated Voltage Measurement... 12:29:38 Voltage Offset Correction: v_off_ini = 2711.865 uV, v_off_fin = 2688.430 uV 12:29:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.786 uVs 12:29:38 Integrated Voltage Measurement... 12:29:47 Voltage Offset Correction: v_off_ini = 2720.800 uV, v_off_fin = 2734.989 uV 12:29:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.426 uVs 12:29:47 Integrated Voltage Measurement... 12:29:56 Voltage Offset Correction: v_off_ini = 2742.395 uV, v_off_fin = 2738.934 uV 12:29:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.635 uVs 12:29:56 Integrated Voltage Measurement... 12:30:05 Voltage Offset Correction: v_off_ini = 2729.277 uV, v_off_fin = 2735.342 uV 12:30:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.263 uVs 12:30:05 Integrated Voltage Measurement... 12:30:14 Voltage Offset Correction: v_off_ini = 2722.156 uV, v_off_fin = 2728.731 uV 12:30:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.121 uVs 12:30:14 Integrated Voltage Measurement... 12:30:23 Voltage Offset Correction: v_off_ini = 2727.231 uV, v_off_fin = 2741.518 uV 12:30:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.068 uVs 12:30:28 I1Y Average and RMS of Measurements VT = -255.550 +- 8.789 uVs I1Y = -51.110 +- 1.758 uTm 12:30:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:30:33 Integrated Voltage Measurement... 12:30:42 Voltage Offset Correction: v_off_ini = 2723.351 uV, v_off_fin = 2722.219 uV 12:30:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.956 uVs 12:30:42 Integrated Voltage Measurement... 12:30:51 Voltage Offset Correction: v_off_ini = 2732.326 uV, v_off_fin = 2759.175 uV 12:30:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.430 uVs 12:30:51 Integrated Voltage Measurement... 12:31:00 Voltage Offset Correction: v_off_ini = 2765.543 uV, v_off_fin = 2753.823 uV 12:31:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.249 uVs 12:31:00 Integrated Voltage Measurement... 12:31:09 Voltage Offset Correction: v_off_ini = 2740.000 uV, v_off_fin = 2762.188 uV 12:31:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.160 uVs 12:31:09 Integrated Voltage Measurement... 12:31:18 Voltage Offset Correction: v_off_ini = 2758.686 uV, v_off_fin = 2777.843 uV 12:31:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.785 uVs 12:31:18 Integrated Voltage Measurement... 12:31:27 Voltage Offset Correction: v_off_ini = 2763.521 uV, v_off_fin = 2767.492 uV 12:31:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.000 uVs 12:31:29 I2X Average and RMS of Measurements VT = -31.263 +- 8.226 uVs I2X = 2.876 +- 0.757 uTm^2 12:31:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:31:34 Integrated Voltage Measurement... 12:31:43 Voltage Offset Correction: v_off_ini = 2779.531 uV, v_off_fin = 2776.284 uV 12:31:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.055 uVs 12:31:43 Integrated Voltage Measurement... 12:31:52 Voltage Offset Correction: v_off_ini = 2768.983 uV, v_off_fin = 2773.257 uV 12:31:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.212 uVs 12:31:52 Integrated Voltage Measurement... 12:32:01 Voltage Offset Correction: v_off_ini = 2766.603 uV, v_off_fin = 2777.597 uV 12:32:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.041 uVs 12:32:01 Integrated Voltage Measurement... 12:32:10 Voltage Offset Correction: v_off_ini = 2754.440 uV, v_off_fin = 2762.901 uV 12:32:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.498 uVs 12:32:11 Integrated Voltage Measurement... 12:32:20 Voltage Offset Correction: v_off_ini = 2748.890 uV, v_off_fin = 2744.648 uV 12:32:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.495 uVs 12:32:20 Integrated Voltage Measurement... 12:32:29 Voltage Offset Correction: v_off_ini = 2765.729 uV, v_off_fin = 2759.180 uV 12:32:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.130 uVs 12:32:31 I2Y Average and RMS of Measurements VT = -278.239 +- 1.578 uVs I2Y = -25.598 +- 0.145 uTm^2 12:32:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:32:39 Integrated Voltage Measurement... 12:32:48 Voltage Offset Correction: v_off_ini = 2775.608 uV, v_off_fin = 2783.881 uV 12:32:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -76.389 uVs 12:32:48 Integrated Voltage Measurement... 12:32:57 Voltage Offset Correction: v_off_ini = 2777.664 uV, v_off_fin = 2776.715 uV 12:32:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.507 uVs 12:32:57 Integrated Voltage Measurement... 12:33:06 Voltage Offset Correction: v_off_ini = 2760.960 uV, v_off_fin = 2765.979 uV 12:33:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.834 uVs 12:33:06 Integrated Voltage Measurement... 12:33:15 Voltage Offset Correction: v_off_ini = 2785.267 uV, v_off_fin = 2765.795 uV 12:33:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 75.650 uVs 12:33:15 Integrated Voltage Measurement... 12:33:24 Voltage Offset Correction: v_off_ini = 2757.042 uV, v_off_fin = 2766.175 uV 12:33:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.007 uVs 12:33:24 Integrated Voltage Measurement... 12:33:33 Voltage Offset Correction: v_off_ini = 2767.071 uV, v_off_fin = 2756.824 uV 12:33:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.991 uVs 12:33:37 I1X Average and RMS of Measurements VT = -82.896 +- 9.469 uVs I1X = 16.580 +- 1.894 uTm 12:33:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:33:44 Integrated Voltage Measurement... 12:33:53 Voltage Offset Correction: v_off_ini = 2770.474 uV, v_off_fin = 2760.450 uV 12:33:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.617 uVs 12:33:53 Integrated Voltage Measurement... 12:34:02 Voltage Offset Correction: v_off_ini = 2782.616 uV, v_off_fin = 2801.029 uV 12:34:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.450 uVs 12:34:02 Integrated Voltage Measurement... 12:34:11 Voltage Offset Correction: v_off_ini = 2784.598 uV, v_off_fin = 2780.931 uV 12:34:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.913 uVs 12:34:11 Integrated Voltage Measurement... 12:34:20 Voltage Offset Correction: v_off_ini = 2787.753 uV, v_off_fin = 2781.095 uV 12:34:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.325 uVs 12:34:20 Integrated Voltage Measurement... 12:34:29 Voltage Offset Correction: v_off_ini = 2769.546 uV, v_off_fin = 2763.757 uV 12:34:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -254.851 uVs 12:34:29 Integrated Voltage Measurement... 12:34:38 Voltage Offset Correction: v_off_ini = 2765.631 uV, v_off_fin = 2758.078 uV 12:34:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.095 uVs 12:34:42 I1Y Average and RMS of Measurements VT = -266.209 +- 0.238 uVs I1Y = -53.243 +- 0.049 uTm 12:34:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:34:47 Integrated Voltage Measurement... 12:34:56 Voltage Offset Correction: v_off_ini = 2752.293 uV, v_off_fin = 2751.276 uV 12:34:56 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -44.650 uVs 12:34:56 Integrated Voltage Measurement... 12:35:05 Voltage Offset Correction: v_off_ini = 2735.038 uV, v_off_fin = 2753.984 uV 12:35:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.546 uVs 12:35:06 Integrated Voltage Measurement... 12:35:14 Voltage Offset Correction: v_off_ini = 2723.877 uV, v_off_fin = 2728.060 uV 12:35:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.453 uVs 12:35:15 Integrated Voltage Measurement... 12:35:24 Voltage Offset Correction: v_off_ini = 2737.185 uV, v_off_fin = 2753.500 uV 12:35:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.636 uVs 12:35:24 Integrated Voltage Measurement... 12:35:33 Voltage Offset Correction: v_off_ini = 2745.825 uV, v_off_fin = 2758.326 uV 12:35:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.196 uVs 12:35:33 Integrated Voltage Measurement... 12:35:42 Voltage Offset Correction: v_off_ini = 2757.790 uV, v_off_fin = 2765.510 uV 12:35:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 9.464 uVs 12:35:44 I2X Average and RMS of Measurements VT = -27.324 +- 10.233 uVs I2X = 2.514 +- 0.941 uTm^2 12:35:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:35:49 Integrated Voltage Measurement... 12:35:58 Voltage Offset Correction: v_off_ini = 2757.503 uV, v_off_fin = 2746.646 uV 12:35:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.045 uVs 12:35:58 Integrated Voltage Measurement... 12:36:07 Voltage Offset Correction: v_off_ini = 2759.281 uV, v_off_fin = 2760.318 uV 12:36:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 275.090 uVs 12:36:07 Integrated Voltage Measurement... 12:36:16 Voltage Offset Correction: v_off_ini = 2762.362 uV, v_off_fin = 2770.701 uV 12:36:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.662 uVs 12:36:16 Integrated Voltage Measurement... 12:36:25 Voltage Offset Correction: v_off_ini = 2740.788 uV, v_off_fin = 2747.421 uV 12:36:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 285.923 uVs 12:36:25 Integrated Voltage Measurement... 12:36:34 Voltage Offset Correction: v_off_ini = 2752.909 uV, v_off_fin = 2752.178 uV 12:36:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.126 uVs 12:36:34 Integrated Voltage Measurement... 12:36:43 Voltage Offset Correction: v_off_ini = 2761.493 uV, v_off_fin = 2759.827 uV 12:36:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.302 uVs 12:36:46 I2Y Average and RMS of Measurements VT = -279.858 +- 1.743 uVs I2Y = -25.748 +- 0.160 uTm^2 12:36:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:36:54 Integrated Voltage Measurement... 12:37:03 Voltage Offset Correction: v_off_ini = 2742.042 uV, v_off_fin = 2732.522 uV 12:37:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -82.149 uVs 12:37:03 Integrated Voltage Measurement... 12:37:12 Voltage Offset Correction: v_off_ini = 2730.975 uV, v_off_fin = 2764.137 uV 12:37:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 90.669 uVs 12:37:12 Integrated Voltage Measurement... 12:37:21 Voltage Offset Correction: v_off_ini = 2746.654 uV, v_off_fin = 2753.525 uV 12:37:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.803 uVs 12:37:21 Integrated Voltage Measurement... 12:37:30 Voltage Offset Correction: v_off_ini = 2746.650 uV, v_off_fin = 2758.733 uV 12:37:30 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.493 uVs 12:37:30 Integrated Voltage Measurement... 12:37:39 Voltage Offset Correction: v_off_ini = 2739.043 uV, v_off_fin = 2745.536 uV 12:37:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -97.477 uVs 12:37:39 Integrated Voltage Measurement... 12:37:48 Voltage Offset Correction: v_off_ini = 2732.461 uV, v_off_fin = 2754.132 uV 12:37:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.523 uVs 12:37:52 I1X Average and RMS of Measurements VT = -84.686 +- 1.924 uVs I1X = 16.939 +- 0.386 uTm 12:37:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:37:59 Integrated Voltage Measurement... 12:38:08 Voltage Offset Correction: v_off_ini = 2703.337 uV, v_off_fin = 2707.226 uV 12:38:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.958 uVs 12:38:08 Integrated Voltage Measurement... 12:38:17 Voltage Offset Correction: v_off_ini = 2727.623 uV, v_off_fin = 2746.519 uV 12:38:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 267.138 uVs 12:38:17 Integrated Voltage Measurement... 12:38:26 Voltage Offset Correction: v_off_ini = 2748.400 uV, v_off_fin = 2735.424 uV 12:38:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -264.371 uVs 12:38:26 Integrated Voltage Measurement... 12:38:35 Voltage Offset Correction: v_off_ini = 2764.540 uV, v_off_fin = 2759.618 uV 12:38:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.827 uVs 12:38:35 Integrated Voltage Measurement... 12:38:44 Voltage Offset Correction: v_off_ini = 2771.815 uV, v_off_fin = 2747.947 uV 12:38:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -270.075 uVs 12:38:44 Integrated Voltage Measurement... 12:38:53 Voltage Offset Correction: v_off_ini = 2770.857 uV, v_off_fin = 2775.737 uV 12:38:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 258.283 uVs 12:38:57 I1Y Average and RMS of Measurements VT = -262.609 +- 1.125 uVs I1Y = -52.518 +- 0.224 uTm 12:39:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:39:02 Integrated Voltage Measurement... 12:39:11 Voltage Offset Correction: v_off_ini = 2743.054 uV, v_off_fin = 2750.220 uV 12:39:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -55.512 uVs 12:39:11 Integrated Voltage Measurement... 12:39:20 Voltage Offset Correction: v_off_ini = 2763.406 uV, v_off_fin = 2769.584 uV 12:39:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.338 uVs 12:39:20 Integrated Voltage Measurement... 12:39:29 Voltage Offset Correction: v_off_ini = 2747.598 uV, v_off_fin = 2722.435 uV 12:39:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.554 uVs 12:39:29 Integrated Voltage Measurement... 12:39:38 Voltage Offset Correction: v_off_ini = 2763.707 uV, v_off_fin = 2768.337 uV 12:39:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -10.700 uVs 12:39:38 Integrated Voltage Measurement... 12:39:47 Voltage Offset Correction: v_off_ini = 2737.568 uV, v_off_fin = 2739.350 uV 12:39:47 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -28.629 uVs 12:39:47 Integrated Voltage Measurement... 12:39:56 Voltage Offset Correction: v_off_ini = 2776.441 uV, v_off_fin = 2767.749 uV 12:39:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.419 uVs 12:39:59 I2X Average and RMS of Measurements VT = -20.626 +- 18.373 uVs I2X = 1.897 +- 1.690 uTm^2 12:40:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:40:04 Integrated Voltage Measurement... 12:40:13 Voltage Offset Correction: v_off_ini = 2769.020 uV, v_off_fin = 2763.479 uV 12:40:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -292.981 uVs 12:40:13 Integrated Voltage Measurement... 12:40:22 Voltage Offset Correction: v_off_ini = 2782.176 uV, v_off_fin = 2787.019 uV 12:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.488 uVs 12:40:22 Integrated Voltage Measurement... 12:40:31 Voltage Offset Correction: v_off_ini = 2774.607 uV, v_off_fin = 2788.526 uV 12:40:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.895 uVs 12:40:31 Integrated Voltage Measurement... 12:40:40 Voltage Offset Correction: v_off_ini = 2805.265 uV, v_off_fin = 2790.484 uV 12:40:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.840 uVs 12:40:40 Integrated Voltage Measurement... 12:40:49 Voltage Offset Correction: v_off_ini = 2810.579 uV, v_off_fin = 2795.643 uV 12:40:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -290.986 uVs 12:40:49 Integrated Voltage Measurement... 12:40:58 Voltage Offset Correction: v_off_ini = 2781.888 uV, v_off_fin = 2768.608 uV 12:40:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 300.586 uVs 12:41:00 I2Y Average and RMS of Measurements VT = -279.796 +- 12.467 uVs I2Y = -25.742 +- 1.148 uTm^2 12:41:04 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:41:09 Integrated Voltage Measurement... 12:41:18 Voltage Offset Correction: v_off_ini = 2761.840 uV, v_off_fin = 2770.300 uV 12:41:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -73.345 uVs 12:41:18 Integrated Voltage Measurement... 12:41:27 Voltage Offset Correction: v_off_ini = 2752.815 uV, v_off_fin = 2745.595 uV 12:41:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.818 uVs 12:41:27 Integrated Voltage Measurement... 12:41:36 Voltage Offset Correction: v_off_ini = 2749.149 uV, v_off_fin = 2768.850 uV 12:41:36 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.350 uVs 12:41:36 Integrated Voltage Measurement... 12:41:45 Voltage Offset Correction: v_off_ini = 2758.954 uV, v_off_fin = 2746.569 uV 12:41:45 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.370 uVs 12:41:45 Integrated Voltage Measurement... 12:41:54 Voltage Offset Correction: v_off_ini = 2743.283 uV, v_off_fin = 2754.681 uV 12:41:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.952 uVs 12:41:54 Integrated Voltage Measurement... 12:42:03 Voltage Offset Correction: v_off_ini = 2756.422 uV, v_off_fin = 2750.068 uV 12:42:03 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.742 uVs 12:42:07 I1X Average and RMS of Measurements VT = -69.596 +- 12.638 uVs I1X = 13.920 +- 2.528 uTm 12:42:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:42:14 Integrated Voltage Measurement... 12:42:23 Voltage Offset Correction: v_off_ini = 2781.144 uV, v_off_fin = 2771.936 uV 12:42:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -275.804 uVs 12:42:23 Integrated Voltage Measurement... 12:42:32 Voltage Offset Correction: v_off_ini = 2764.648 uV, v_off_fin = 2778.434 uV 12:42:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 283.844 uVs 12:42:32 Integrated Voltage Measurement... 12:42:41 Voltage Offset Correction: v_off_ini = 2748.714 uV, v_off_fin = 2746.830 uV 12:42:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -269.864 uVs 12:42:41 Integrated Voltage Measurement... 12:42:50 Voltage Offset Correction: v_off_ini = 2765.790 uV, v_off_fin = 2758.398 uV 12:42:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 293.403 uVs 12:42:50 Integrated Voltage Measurement... 12:42:59 Voltage Offset Correction: v_off_ini = 2756.380 uV, v_off_fin = 2741.256 uV 12:42:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -284.405 uVs 12:42:59 Integrated Voltage Measurement... 12:43:08 Voltage Offset Correction: v_off_ini = 2760.598 uV, v_off_fin = 2770.273 uV 12:43:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 263.341 uVs 12:43:12 I1Y Average and RMS of Measurements VT = -278.443 +- 3.315 uVs I1Y = -55.683 +- 0.663 uTm 12:43:14 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:43:17 Integrated Voltage Measurement... 12:43:26 Voltage Offset Correction: v_off_ini = 2765.929 uV, v_off_fin = 2756.752 uV 12:43:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -13.993 uVs 12:43:26 Integrated Voltage Measurement... 12:43:35 Voltage Offset Correction: v_off_ini = 2758.798 uV, v_off_fin = 2791.600 uV 12:43:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 10.473 uVs 12:43:35 Integrated Voltage Measurement... 12:43:44 Voltage Offset Correction: v_off_ini = 2785.470 uV, v_off_fin = 2791.891 uV 12:43:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 6.682 uVs 12:43:44 Integrated Voltage Measurement... 12:43:53 Voltage Offset Correction: v_off_ini = 2785.051 uV, v_off_fin = 2799.787 uV 12:43:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 5.852 uVs 12:43:53 Integrated Voltage Measurement... 12:44:02 Voltage Offset Correction: v_off_ini = 2797.900 uV, v_off_fin = 2798.113 uV 12:44:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.443 uVs 12:44:02 Integrated Voltage Measurement... 12:44:11 Voltage Offset Correction: v_off_ini = 2796.095 uV, v_off_fin = 2811.916 uV 12:44:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.608 uVs 12:44:13 I2X Average and RMS of Measurements VT = -12.448 +- 10.591 uVs I2X = 1.145 +- 0.974 uTm^2 12:44:16 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:44:19 Integrated Voltage Measurement... 12:44:28 Voltage Offset Correction: v_off_ini = 2804.509 uV, v_off_fin = 2795.148 uV 12:44:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.556 uVs 12:44:28 Integrated Voltage Measurement... 12:44:37 Voltage Offset Correction: v_off_ini = 2799.793 uV, v_off_fin = 2783.964 uV 12:44:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.264 uVs 12:44:37 Integrated Voltage Measurement... 12:44:46 Voltage Offset Correction: v_off_ini = 2783.194 uV, v_off_fin = 2785.197 uV 12:44:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -286.720 uVs 12:44:46 Integrated Voltage Measurement... 12:44:55 Voltage Offset Correction: v_off_ini = 2808.650 uV, v_off_fin = 2805.994 uV 12:44:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.789 uVs 12:44:55 Integrated Voltage Measurement... 12:45:04 Voltage Offset Correction: v_off_ini = 2774.398 uV, v_off_fin = 2770.293 uV 12:45:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.983 uVs 12:45:04 Integrated Voltage Measurement... 12:45:13 Voltage Offset Correction: v_off_ini = 2782.394 uV, v_off_fin = 2792.488 uV 12:45:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.057 uVs 12:45:15 I2Y Average and RMS of Measurements VT = -286.062 +- 5.213 uVs I2Y = -26.318 +- 0.479 uTm^2 12:45:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:45:35 Integrated Voltage Measurement... 12:45:44 Voltage Offset Correction: v_off_ini = 2804.951 uV, v_off_fin = 2812.005 uV 12:45:44 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -99.451 uVs 12:45:44 Integrated Voltage Measurement... 12:45:53 Voltage Offset Correction: v_off_ini = 2809.577 uV, v_off_fin = 2801.991 uV 12:45:53 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.046 uVs 12:45:53 Integrated Voltage Measurement... 12:46:02 Voltage Offset Correction: v_off_ini = 2804.621 uV, v_off_fin = 2784.039 uV 12:46:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.841 uVs 12:46:02 Integrated Voltage Measurement... 12:46:11 Voltage Offset Correction: v_off_ini = 2789.462 uV, v_off_fin = 2783.645 uV 12:46:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.667 uVs 12:46:11 Integrated Voltage Measurement... 12:46:20 Voltage Offset Correction: v_off_ini = 2790.297 uV, v_off_fin = 2785.409 uV 12:46:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.559 uVs 12:46:20 Integrated Voltage Measurement... 12:46:29 Voltage Offset Correction: v_off_ini = 2772.547 uV, v_off_fin = 2770.139 uV 12:46:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.474 uVs 12:46:34 I1X Average and RMS of Measurements VT = -79.340 +- 14.929 uVs I1X = 15.869 +- 2.986 uTm 12:46:36 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:46:40 Integrated Voltage Measurement... 12:46:49 Voltage Offset Correction: v_off_ini = 2818.154 uV, v_off_fin = 2808.465 uV 12:46:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.901 uVs 12:46:49 Integrated Voltage Measurement... 12:46:58 Voltage Offset Correction: v_off_ini = 2808.572 uV, v_off_fin = 2798.475 uV 12:46:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.551 uVs 12:46:58 Integrated Voltage Measurement... 12:47:07 Voltage Offset Correction: v_off_ini = 2818.770 uV, v_off_fin = 2795.334 uV 12:47:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.087 uVs 12:47:07 Integrated Voltage Measurement... 12:47:16 Voltage Offset Correction: v_off_ini = 2805.254 uV, v_off_fin = 2816.792 uV 12:47:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.918 uVs 12:47:16 Integrated Voltage Measurement... 12:47:25 Voltage Offset Correction: v_off_ini = 2801.214 uV, v_off_fin = 2789.143 uV 12:47:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.747 uVs 12:47:25 Integrated Voltage Measurement... 12:47:34 Voltage Offset Correction: v_off_ini = 2816.416 uV, v_off_fin = 2827.888 uV 12:47:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.630 uVs 12:47:38 I1Y Average and RMS of Measurements VT = -234.472 +- 6.869 uVs I1Y = -46.894 +- 1.374 uTm 12:47:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:47:46 Integrated Voltage Measurement... 12:47:55 Voltage Offset Correction: v_off_ini = 2830.174 uV, v_off_fin = 2815.009 uV 12:47:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.225 uVs 12:47:55 Integrated Voltage Measurement... 12:48:04 Voltage Offset Correction: v_off_ini = 2786.852 uV, v_off_fin = 2810.103 uV 12:48:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.755 uVs 12:48:04 Integrated Voltage Measurement... 12:48:13 Voltage Offset Correction: v_off_ini = 2788.095 uV, v_off_fin = 2783.904 uV 12:48:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.164 uVs 12:48:13 Integrated Voltage Measurement... 12:48:22 Voltage Offset Correction: v_off_ini = 2805.478 uV, v_off_fin = 2795.782 uV 12:48:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 59.635 uVs 12:48:22 Integrated Voltage Measurement... 12:48:31 Voltage Offset Correction: v_off_ini = 2807.554 uV, v_off_fin = 2786.526 uV 12:48:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.985 uVs 12:48:31 Integrated Voltage Measurement... 12:48:40 Voltage Offset Correction: v_off_ini = 2799.841 uV, v_off_fin = 2818.178 uV 12:48:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.386 uVs 12:48:43 I2X Average and RMS of Measurements VT = -50.025 +- 6.423 uVs I2X = 4.602 +- 0.591 uTm^2 12:48:48 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:48:50 Integrated Voltage Measurement... 12:48:59 Voltage Offset Correction: v_off_ini = 2830.017 uV, v_off_fin = 2832.477 uV 12:48:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.952 uVs 12:48:59 Integrated Voltage Measurement... 12:49:08 Voltage Offset Correction: v_off_ini = 2811.207 uV, v_off_fin = 2806.396 uV 12:49:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.928 uVs 12:49:09 Integrated Voltage Measurement... 12:49:17 Voltage Offset Correction: v_off_ini = 2832.108 uV, v_off_fin = 2841.648 uV 12:49:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.353 uVs 12:49:18 Integrated Voltage Measurement... 12:49:27 Voltage Offset Correction: v_off_ini = 2862.071 uV, v_off_fin = 2849.116 uV 12:49:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.808 uVs 12:49:27 Integrated Voltage Measurement... 12:49:36 Voltage Offset Correction: v_off_ini = 2826.950 uV, v_off_fin = 2835.014 uV 12:49:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.810 uVs 12:49:36 Integrated Voltage Measurement... 12:49:45 Voltage Offset Correction: v_off_ini = 2807.190 uV, v_off_fin = 2821.160 uV 12:49:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.648 uVs 12:49:47 I2Y Average and RMS of Measurements VT = -254.250 +- 7.481 uVs I2Y = -23.391 +- 0.688 uTm^2 12:49:52 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:49:56 Integrated Voltage Measurement... 12:50:05 Voltage Offset Correction: v_off_ini = 2822.091 uV, v_off_fin = 2802.460 uV 12:50:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -95.873 uVs 12:50:05 Integrated Voltage Measurement... 12:50:14 Voltage Offset Correction: v_off_ini = 2810.997 uV, v_off_fin = 2808.585 uV 12:50:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 92.714 uVs 12:50:14 Integrated Voltage Measurement... 12:50:23 Voltage Offset Correction: v_off_ini = 2785.725 uV, v_off_fin = 2786.742 uV 12:50:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.010 uVs 12:50:23 Integrated Voltage Measurement... 12:50:32 Voltage Offset Correction: v_off_ini = 2793.001 uV, v_off_fin = 2817.131 uV 12:50:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 88.075 uVs 12:50:32 Integrated Voltage Measurement... 12:50:41 Voltage Offset Correction: v_off_ini = 2819.156 uV, v_off_fin = 2814.795 uV 12:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.579 uVs 12:50:41 Integrated Voltage Measurement... 12:50:50 Voltage Offset Correction: v_off_ini = 2819.139 uV, v_off_fin = 2824.478 uV 12:50:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.098 uVs 12:50:54 I1X Average and RMS of Measurements VT = -88.058 +- 4.824 uVs I1X = 17.613 +- 0.966 uTm 12:50:57 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:51:01 Integrated Voltage Measurement... 12:51:10 Voltage Offset Correction: v_off_ini = 2813.263 uV, v_off_fin = 2824.547 uV 12:51:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.492 uVs 12:51:10 Integrated Voltage Measurement... 12:51:19 Voltage Offset Correction: v_off_ini = 2853.330 uV, v_off_fin = 2842.209 uV 12:51:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.464 uVs 12:51:19 Integrated Voltage Measurement... 12:51:28 Voltage Offset Correction: v_off_ini = 2850.516 uV, v_off_fin = 2844.932 uV 12:51:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.292 uVs 12:51:28 Integrated Voltage Measurement... 12:51:37 Voltage Offset Correction: v_off_ini = 2832.460 uV, v_off_fin = 2820.256 uV 12:51:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.784 uVs 12:51:37 Integrated Voltage Measurement... 12:51:46 Voltage Offset Correction: v_off_ini = 2825.963 uV, v_off_fin = 2807.730 uV 12:51:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.309 uVs 12:51:46 Integrated Voltage Measurement... 12:51:55 Voltage Offset Correction: v_off_ini = 2835.399 uV, v_off_fin = 2841.956 uV 12:51:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.837 uVs 12:51:59 I1Y Average and RMS of Measurements VT = -249.529 +- 3.689 uVs I1Y = -49.906 +- 0.738 uTm 12:52:04 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:52:07 Integrated Voltage Measurement... 12:52:16 Voltage Offset Correction: v_off_ini = 2813.984 uV, v_off_fin = 2807.597 uV 12:52:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.198 uVs 12:52:16 Integrated Voltage Measurement... 12:52:25 Voltage Offset Correction: v_off_ini = 2831.581 uV, v_off_fin = 2834.813 uV 12:52:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.644 uVs 12:52:25 Integrated Voltage Measurement... 12:52:34 Voltage Offset Correction: v_off_ini = 2858.095 uV, v_off_fin = 2837.130 uV 12:52:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.006 uVs 12:52:34 Integrated Voltage Measurement... 12:52:43 Voltage Offset Correction: v_off_ini = 2857.360 uV, v_off_fin = 2856.042 uV 12:52:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 27.684 uVs 12:52:43 Integrated Voltage Measurement... 12:52:52 Voltage Offset Correction: v_off_ini = 2821.426 uV, v_off_fin = 2808.867 uV 12:52:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.438 uVs 12:52:52 Integrated Voltage Measurement... 12:53:01 Voltage Offset Correction: v_off_ini = 2824.485 uV, v_off_fin = 2852.395 uV 12:53:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.275 uVs 12:53:03 I2X Average and RMS of Measurements VT = -37.874 +- 10.002 uVs I2X = 3.484 +- 0.920 uTm^2 12:53:08 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:53:11 Integrated Voltage Measurement... 12:53:20 Voltage Offset Correction: v_off_ini = 2834.405 uV, v_off_fin = 2840.129 uV 12:53:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.457 uVs 12:53:20 Integrated Voltage Measurement... 12:53:29 Voltage Offset Correction: v_off_ini = 2829.322 uV, v_off_fin = 2836.718 uV 12:53:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.412 uVs 12:53:29 Integrated Voltage Measurement... 12:53:38 Voltage Offset Correction: v_off_ini = 2824.635 uV, v_off_fin = 2819.525 uV 12:53:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.035 uVs 12:53:38 Integrated Voltage Measurement... 12:53:47 Voltage Offset Correction: v_off_ini = 2825.873 uV, v_off_fin = 2807.171 uV 12:53:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.708 uVs 12:53:47 Integrated Voltage Measurement... 12:53:56 Voltage Offset Correction: v_off_ini = 2816.103 uV, v_off_fin = 2815.004 uV 12:53:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.509 uVs 12:53:56 Integrated Voltage Measurement... 12:54:05 Voltage Offset Correction: v_off_ini = 2832.870 uV, v_off_fin = 2826.864 uV 12:54:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 280.438 uVs 12:54:07 I2Y Average and RMS of Measurements VT = -256.093 +- 3.321 uVs I2Y = -23.561 +- 0.306 uTm^2 12:54:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:54:16 Integrated Voltage Measurement... 12:54:25 Voltage Offset Correction: v_off_ini = 2870.319 uV, v_off_fin = 2861.047 uV 12:54:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -109.807 uVs 12:54:25 Integrated Voltage Measurement... 12:54:34 Voltage Offset Correction: v_off_ini = 2849.046 uV, v_off_fin = 2852.097 uV 12:54:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 103.126 uVs 12:54:34 Integrated Voltage Measurement... 12:54:43 Voltage Offset Correction: v_off_ini = 2867.175 uV, v_off_fin = 2862.328 uV 12:54:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.141 uVs 12:54:43 Integrated Voltage Measurement... 12:54:52 Voltage Offset Correction: v_off_ini = 2880.626 uV, v_off_fin = 2883.200 uV 12:54:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.942 uVs 12:54:52 Integrated Voltage Measurement... 12:55:01 Voltage Offset Correction: v_off_ini = 2866.383 uV, v_off_fin = 2862.796 uV 12:55:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.487 uVs 12:55:01 Integrated Voltage Measurement... 12:55:10 Voltage Offset Correction: v_off_ini = 2854.293 uV, v_off_fin = 2833.922 uV 12:55:10 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.487 uVs 12:55:14 I1X Average and RMS of Measurements VT = -99.332 +- 8.398 uVs I1X = 19.867 +- 1.680 uTm 12:55:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:55:21 Integrated Voltage Measurement... 12:55:30 Voltage Offset Correction: v_off_ini = 2828.029 uV, v_off_fin = 2821.642 uV 12:55:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.483 uVs 12:55:30 Integrated Voltage Measurement... 12:55:39 Voltage Offset Correction: v_off_ini = 2847.538 uV, v_off_fin = 2851.800 uV 12:55:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.703 uVs 12:55:39 Integrated Voltage Measurement... 12:55:48 Voltage Offset Correction: v_off_ini = 2826.266 uV, v_off_fin = 2825.754 uV 12:55:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.824 uVs 12:55:48 Integrated Voltage Measurement... 12:55:57 Voltage Offset Correction: v_off_ini = 2839.067 uV, v_off_fin = 2843.206 uV 12:55:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.362 uVs 12:55:57 Integrated Voltage Measurement... 12:56:06 Voltage Offset Correction: v_off_ini = 2817.240 uV, v_off_fin = 2814.067 uV 12:56:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.941 uVs 12:56:06 Integrated Voltage Measurement... 12:56:15 Voltage Offset Correction: v_off_ini = 2823.854 uV, v_off_fin = 2832.732 uV 12:56:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.354 uVs 12:56:19 I1Y Average and RMS of Measurements VT = -255.778 +- 2.928 uVs I1Y = -51.156 +- 0.586 uTm 12:56:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:56:27 Integrated Voltage Measurement... 12:56:36 Voltage Offset Correction: v_off_ini = 2851.712 uV, v_off_fin = 2838.111 uV 12:56:36 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -32.554 uVs 12:56:36 Integrated Voltage Measurement... 12:56:45 Voltage Offset Correction: v_off_ini = 2833.391 uV, v_off_fin = 2830.976 uV 12:56:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.915 uVs 12:56:45 Integrated Voltage Measurement... 12:56:54 Voltage Offset Correction: v_off_ini = 2846.229 uV, v_off_fin = 2843.608 uV 12:56:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.884 uVs 12:56:54 Integrated Voltage Measurement... 12:57:03 Voltage Offset Correction: v_off_ini = 2866.803 uV, v_off_fin = 2878.991 uV 12:57:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.581 uVs 12:57:03 Integrated Voltage Measurement... 12:57:12 Voltage Offset Correction: v_off_ini = 2865.297 uV, v_off_fin = 2860.317 uV 12:57:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.206 uVs 12:57:12 Integrated Voltage Measurement... 12:57:21 Voltage Offset Correction: v_off_ini = 2857.703 uV, v_off_fin = 2845.594 uV 12:57:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 23.958 uVs 12:57:24 I2X Average and RMS of Measurements VT = -36.016 +- 2.340 uVs I2X = 3.313 +- 0.215 uTm^2 12:57:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:57:31 Integrated Voltage Measurement... 12:57:40 Voltage Offset Correction: v_off_ini = 2849.570 uV, v_off_fin = 2845.500 uV 12:57:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.439 uVs 12:57:40 Integrated Voltage Measurement... 12:57:49 Voltage Offset Correction: v_off_ini = 2839.928 uV, v_off_fin = 2850.940 uV 12:57:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.871 uVs 12:57:49 Integrated Voltage Measurement... 12:57:58 Voltage Offset Correction: v_off_ini = 2851.153 uV, v_off_fin = 2856.714 uV 12:57:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.220 uVs 12:57:58 Integrated Voltage Measurement... 12:58:07 Voltage Offset Correction: v_off_ini = 2845.302 uV, v_off_fin = 2853.282 uV 12:58:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.956 uVs 12:58:07 Integrated Voltage Measurement... 12:58:16 Voltage Offset Correction: v_off_ini = 2853.711 uV, v_off_fin = 2843.910 uV 12:58:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.799 uVs 12:58:16 Integrated Voltage Measurement... 12:58:25 Voltage Offset Correction: v_off_ini = 2825.443 uV, v_off_fin = 2824.682 uV 12:58:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.885 uVs 12:58:28 I2Y Average and RMS of Measurements VT = -266.695 +- 2.571 uVs I2Y = -24.536 +- 0.236 uTm^2 12:58:33 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:58:37 Integrated Voltage Measurement... 12:58:46 Voltage Offset Correction: v_off_ini = 2833.118 uV, v_off_fin = 2834.155 uV 12:58:46 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -121.634 uVs 12:58:46 Integrated Voltage Measurement... 12:58:55 Voltage Offset Correction: v_off_ini = 2820.697 uV, v_off_fin = 2830.558 uV 12:58:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.995 uVs 12:58:55 Integrated Voltage Measurement... 12:59:04 Voltage Offset Correction: v_off_ini = 2838.506 uV, v_off_fin = 2838.529 uV 12:59:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.111 uVs 12:59:04 Integrated Voltage Measurement... 12:59:13 Voltage Offset Correction: v_off_ini = 2854.654 uV, v_off_fin = 2844.685 uV 12:59:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.794 uVs 12:59:13 Integrated Voltage Measurement... 12:59:22 Voltage Offset Correction: v_off_ini = 2806.847 uV, v_off_fin = 2832.194 uV 12:59:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.304 uVs 12:59:22 Integrated Voltage Measurement... 12:59:31 Voltage Offset Correction: v_off_ini = 2835.580 uV, v_off_fin = 2829.792 uV 12:59:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.541 uVs 12:59:35 I1X Average and RMS of Measurements VT = -99.563 +- 9.938 uVs I1X = 19.914 +- 1.989 uTm 12:59:37 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:59:42 Integrated Voltage Measurement... 12:59:51 Voltage Offset Correction: v_off_ini = 2799.220 uV, v_off_fin = 2799.276 uV 12:59:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -258.960 uVs 12:59:51 Integrated Voltage Measurement... 13:00:00 Voltage Offset Correction: v_off_ini = 2823.009 uV, v_off_fin = 2840.237 uV 13:00:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 284.024 uVs 13:00:00 Integrated Voltage Measurement... 13:00:09 Voltage Offset Correction: v_off_ini = 2819.835 uV, v_off_fin = 2807.710 uV 13:00:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.257 uVs 13:00:09 Integrated Voltage Measurement... 13:00:18 Voltage Offset Correction: v_off_ini = 2845.852 uV, v_off_fin = 2842.368 uV 13:00:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.202 uVs 13:00:18 Integrated Voltage Measurement... 13:00:27 Voltage Offset Correction: v_off_ini = 2836.247 uV, v_off_fin = 2814.324 uV 13:00:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.924 uVs 13:00:27 Integrated Voltage Measurement... 13:00:36 Voltage Offset Correction: v_off_ini = 2833.421 uV, v_off_fin = 2847.266 uV 13:00:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.996 uVs 13:00:40 I1Y Average and RMS of Measurements VT = -265.060 +- 5.654 uVs I1Y = -53.013 +- 1.132 uTm 13:00:45 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:00:48 Integrated Voltage Measurement... 13:00:56 Voltage Offset Correction: v_off_ini = 2841.119 uV, v_off_fin = 2841.632 uV 13:00:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.211 uVs 13:00:57 Integrated Voltage Measurement... 13:01:06 Voltage Offset Correction: v_off_ini = 2836.900 uV, v_off_fin = 2826.998 uV 13:01:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.446 uVs 13:01:06 Integrated Voltage Measurement... 13:01:15 Voltage Offset Correction: v_off_ini = 2852.728 uV, v_off_fin = 2834.702 uV 13:01:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.044 uVs 13:01:15 Integrated Voltage Measurement... 13:01:24 Voltage Offset Correction: v_off_ini = 2836.055 uV, v_off_fin = 2843.443 uV 13:01:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.275 uVs 13:01:24 Integrated Voltage Measurement... 13:01:33 Voltage Offset Correction: v_off_ini = 2826.934 uV, v_off_fin = 2831.691 uV 13:01:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.713 uVs 13:01:33 Integrated Voltage Measurement... 13:01:42 Voltage Offset Correction: v_off_ini = 2833.554 uV, v_off_fin = 2847.927 uV 13:01:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.167 uVs 13:01:44 I2X Average and RMS of Measurements VT = -56.976 +- 1.547 uVs I2X = 5.242 +- 0.142 uTm^2 13:01:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:01:52 Integrated Voltage Measurement... 13:02:01 Voltage Offset Correction: v_off_ini = 2819.371 uV, v_off_fin = 2839.159 uV 13:02:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.413 uVs 13:02:01 Integrated Voltage Measurement... 13:02:10 Voltage Offset Correction: v_off_ini = 2818.202 uV, v_off_fin = 2825.103 uV 13:02:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.792 uVs 13:02:10 Integrated Voltage Measurement... 13:02:19 Voltage Offset Correction: v_off_ini = 2841.363 uV, v_off_fin = 2832.320 uV 13:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.056 uVs 13:02:19 Integrated Voltage Measurement... 13:02:28 Voltage Offset Correction: v_off_ini = 2817.745 uV, v_off_fin = 2829.312 uV 13:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.403 uVs 13:02:28 Integrated Voltage Measurement... 13:02:37 Voltage Offset Correction: v_off_ini = 2834.360 uV, v_off_fin = 2827.369 uV 13:02:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.826 uVs 13:02:37 Integrated Voltage Measurement... 13:02:46 Voltage Offset Correction: v_off_ini = 2813.784 uV, v_off_fin = 2807.638 uV 13:02:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 284.235 uVs 13:02:48 I2Y Average and RMS of Measurements VT = -284.454 +- 5.926 uVs I2Y = -26.170 +- 0.545 uTm^2 13:02:53 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:02:57 Integrated Voltage Measurement... 13:03:06 Voltage Offset Correction: v_off_ini = 2808.327 uV, v_off_fin = 2804.333 uV 13:03:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -101.778 uVs 13:03:06 Integrated Voltage Measurement... 13:03:15 Voltage Offset Correction: v_off_ini = 2827.663 uV, v_off_fin = 2822.764 uV 13:03:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.294 uVs 13:03:15 Integrated Voltage Measurement... 13:03:24 Voltage Offset Correction: v_off_ini = 2823.762 uV, v_off_fin = 2821.699 uV 13:03:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.827 uVs 13:03:24 Integrated Voltage Measurement... 13:03:33 Voltage Offset Correction: v_off_ini = 2817.815 uV, v_off_fin = 2830.449 uV 13:03:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.517 uVs 13:03:33 Integrated Voltage Measurement... 13:03:42 Voltage Offset Correction: v_off_ini = 2826.098 uV, v_off_fin = 2824.507 uV 13:03:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.289 uVs 13:03:42 Integrated Voltage Measurement... 13:03:51 Voltage Offset Correction: v_off_ini = 2809.436 uV, v_off_fin = 2824.275 uV 13:03:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.102 uVs 13:03:55 I1X Average and RMS of Measurements VT = -112.801 +- 4.505 uVs I1X = 22.561 +- 0.901 uTm 13:03:58 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:04:02 Integrated Voltage Measurement... 13:04:11 Voltage Offset Correction: v_off_ini = 2812.132 uV, v_off_fin = 2800.864 uV 13:04:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.270 uVs 13:04:11 Integrated Voltage Measurement... 13:04:20 Voltage Offset Correction: v_off_ini = 2820.149 uV, v_off_fin = 2821.502 uV 13:04:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.285 uVs 13:04:20 Integrated Voltage Measurement... 13:04:29 Voltage Offset Correction: v_off_ini = 2810.306 uV, v_off_fin = 2823.723 uV 13:04:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.647 uVs 13:04:29 Integrated Voltage Measurement... 13:04:38 Voltage Offset Correction: v_off_ini = 2825.484 uV, v_off_fin = 2838.718 uV 13:04:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.251 uVs 13:04:38 Integrated Voltage Measurement... 13:04:47 Voltage Offset Correction: v_off_ini = 2819.217 uV, v_off_fin = 2804.539 uV 13:04:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.883 uVs 13:04:47 Integrated Voltage Measurement... 13:04:56 Voltage Offset Correction: v_off_ini = 2812.714 uV, v_off_fin = 2804.329 uV 13:04:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.265 uVs 13:05:00 I1Y Average and RMS of Measurements VT = -260.600 +- 2.748 uVs I1Y = -52.120 +- 0.550 uTm 13:05:05 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:05:08 Integrated Voltage Measurement... 13:05:17 Voltage Offset Correction: v_off_ini = 2807.029 uV, v_off_fin = 2804.914 uV 13:05:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.176 uVs 13:05:17 Integrated Voltage Measurement... 13:05:26 Voltage Offset Correction: v_off_ini = 2816.651 uV, v_off_fin = 2817.282 uV 13:05:26 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 46.133 uVs 13:05:26 Integrated Voltage Measurement... 13:05:35 Voltage Offset Correction: v_off_ini = 2793.810 uV, v_off_fin = 2773.055 uV 13:05:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.565 uVs 13:05:35 Integrated Voltage Measurement... 13:05:44 Voltage Offset Correction: v_off_ini = 2806.501 uV, v_off_fin = 2823.110 uV 13:05:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.601 uVs 13:05:44 Integrated Voltage Measurement... 13:05:53 Voltage Offset Correction: v_off_ini = 2835.733 uV, v_off_fin = 2828.566 uV 13:05:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.614 uVs 13:05:53 Integrated Voltage Measurement... 13:06:02 Voltage Offset Correction: v_off_ini = 2826.669 uV, v_off_fin = 2831.044 uV 13:06:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.971 uVs 13:06:05 I2X Average and RMS of Measurements VT = -54.843 +- 10.387 uVs I2X = 5.046 +- 0.956 uTm^2 13:06:10 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:06:12 Integrated Voltage Measurement... 13:06:21 Voltage Offset Correction: v_off_ini = 2822.043 uV, v_off_fin = 2845.533 uV 13:06:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.174 uVs 13:06:21 Integrated Voltage Measurement... 13:06:30 Voltage Offset Correction: v_off_ini = 2833.158 uV, v_off_fin = 2816.439 uV 13:06:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.450 uVs 13:06:30 Integrated Voltage Measurement... 13:06:39 Voltage Offset Correction: v_off_ini = 2839.770 uV, v_off_fin = 2838.681 uV 13:06:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.947 uVs 13:06:39 Integrated Voltage Measurement... 13:06:48 Voltage Offset Correction: v_off_ini = 2826.246 uV, v_off_fin = 2813.511 uV 13:06:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.607 uVs 13:06:48 Integrated Voltage Measurement... 13:06:57 Voltage Offset Correction: v_off_ini = 2823.803 uV, v_off_fin = 2838.820 uV 13:06:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.320 uVs 13:06:57 Integrated Voltage Measurement... 13:07:06 Voltage Offset Correction: v_off_ini = 2849.418 uV, v_off_fin = 2830.669 uV 13:07:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.130 uVs 13:07:09 I2Y Average and RMS of Measurements VT = -289.105 +- 5.069 uVs I2Y = -26.598 +- 0.466 uTm^2 13:07:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:07:21 Integrated Voltage Measurement... 13:07:30 Voltage Offset Correction: v_off_ini = 2831.487 uV, v_off_fin = 2824.959 uV 13:07:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -89.159 uVs 13:07:30 Integrated Voltage Measurement... 13:07:39 Voltage Offset Correction: v_off_ini = 2810.632 uV, v_off_fin = 2820.243 uV 13:07:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.118 uVs 13:07:39 Integrated Voltage Measurement... 13:07:48 Voltage Offset Correction: v_off_ini = 2826.528 uV, v_off_fin = 2801.115 uV 13:07:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -109.397 uVs 13:07:48 Integrated Voltage Measurement... 13:07:57 Voltage Offset Correction: v_off_ini = 2803.470 uV, v_off_fin = 2828.074 uV 13:07:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 87.922 uVs 13:07:57 Integrated Voltage Measurement... 13:08:06 Voltage Offset Correction: v_off_ini = 2816.047 uV, v_off_fin = 2824.940 uV 13:08:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.497 uVs 13:08:06 Integrated Voltage Measurement... 13:08:15 Voltage Offset Correction: v_off_ini = 2849.754 uV, v_off_fin = 2830.626 uV 13:08:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 105.942 uVs 13:08:19 I1X Average and RMS of Measurements VT = -106.339 +- 7.068 uVs I1X = 21.269 +- 1.412 uTm 13:08:21 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:08:26 Integrated Voltage Measurement... 13:08:35 Voltage Offset Correction: v_off_ini = 2846.264 uV, v_off_fin = 2835.620 uV 13:08:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.887 uVs 13:08:35 Integrated Voltage Measurement... 13:08:44 Voltage Offset Correction: v_off_ini = 2846.675 uV, v_off_fin = 2872.864 uV 13:08:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.989 uVs 13:08:44 Integrated Voltage Measurement... 13:08:53 Voltage Offset Correction: v_off_ini = 2843.369 uV, v_off_fin = 2828.688 uV 13:08:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.849 uVs 13:08:53 Integrated Voltage Measurement... 13:09:02 Voltage Offset Correction: v_off_ini = 2831.807 uV, v_off_fin = 2860.496 uV 13:09:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.492 uVs 13:09:02 Integrated Voltage Measurement... 13:09:11 Voltage Offset Correction: v_off_ini = 2854.052 uV, v_off_fin = 2836.019 uV 13:09:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.780 uVs 13:09:11 Integrated Voltage Measurement... 13:09:20 Voltage Offset Correction: v_off_ini = 2828.769 uV, v_off_fin = 2832.724 uV 13:09:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 244.819 uVs 13:09:24 I1Y Average and RMS of Measurements VT = -240.303 +- 2.628 uVs I1Y = -48.061 +- 0.526 uTm 13:09:26 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:09:29 Integrated Voltage Measurement... 13:09:38 Voltage Offset Correction: v_off_ini = 2837.601 uV, v_off_fin = 2827.069 uV 13:09:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -51.590 uVs 13:09:38 Integrated Voltage Measurement... 13:09:47 Voltage Offset Correction: v_off_ini = 2829.410 uV, v_off_fin = 2848.077 uV 13:09:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.387 uVs 13:09:47 Integrated Voltage Measurement... 13:09:56 Voltage Offset Correction: v_off_ini = 2827.735 uV, v_off_fin = 2832.984 uV 13:09:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.081 uVs 13:09:56 Integrated Voltage Measurement... 13:10:05 Voltage Offset Correction: v_off_ini = 2858.543 uV, v_off_fin = 2856.408 uV 13:10:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.520 uVs 13:10:05 Integrated Voltage Measurement... 13:10:14 Voltage Offset Correction: v_off_ini = 2877.314 uV, v_off_fin = 2839.720 uV 13:10:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.002 uVs 13:10:14 Integrated Voltage Measurement... 13:10:23 Voltage Offset Correction: v_off_ini = 2847.684 uV, v_off_fin = 2845.372 uV 13:10:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.523 uVs 13:10:25 I2X Average and RMS of Measurements VT = -51.851 +- 5.037 uVs I2X = 4.770 +- 0.463 uTm^2 13:10:28 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:10:30 Integrated Voltage Measurement... 13:10:39 Voltage Offset Correction: v_off_ini = 2819.607 uV, v_off_fin = 2814.854 uV 13:10:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.874 uVs 13:10:39 Integrated Voltage Measurement... 13:10:48 Voltage Offset Correction: v_off_ini = 2817.384 uV, v_off_fin = 2834.160 uV 13:10:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.015 uVs 13:10:49 Integrated Voltage Measurement... 13:10:57 Voltage Offset Correction: v_off_ini = 2852.274 uV, v_off_fin = 2830.608 uV 13:10:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.832 uVs 13:10:58 Integrated Voltage Measurement... 13:11:07 Voltage Offset Correction: v_off_ini = 2838.670 uV, v_off_fin = 2832.725 uV 13:11:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.800 uVs 13:11:07 Integrated Voltage Measurement... 13:11:16 Voltage Offset Correction: v_off_ini = 2827.120 uV, v_off_fin = 2832.124 uV 13:11:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.408 uVs 13:11:16 Integrated Voltage Measurement... 13:11:25 Voltage Offset Correction: v_off_ini = 2818.973 uV, v_off_fin = 2818.893 uV 13:11:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.190 uVs 13:11:27 I2Y Average and RMS of Measurements VT = -264.686 +- 12.218 uVs I2Y = -24.351 +- 1.124 uTm^2 13:11:31 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:11:35 Integrated Voltage Measurement... 13:11:44 Voltage Offset Correction: v_off_ini = 2823.760 uV, v_off_fin = 2845.771 uV 13:11:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.978 uVs 13:11:44 Integrated Voltage Measurement... 13:11:53 Voltage Offset Correction: v_off_ini = 2845.245 uV, v_off_fin = 2837.013 uV 13:11:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.219 uVs 13:11:53 Integrated Voltage Measurement... 13:12:02 Voltage Offset Correction: v_off_ini = 2829.625 uV, v_off_fin = 2801.330 uV 13:12:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -110.371 uVs 13:12:02 Integrated Voltage Measurement... 13:12:11 Voltage Offset Correction: v_off_ini = 2840.561 uV, v_off_fin = 2849.527 uV 13:12:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 65.486 uVs 13:12:11 Integrated Voltage Measurement... 13:12:20 Voltage Offset Correction: v_off_ini = 2846.520 uV, v_off_fin = 2833.586 uV 13:12:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.327 uVs 13:12:20 Integrated Voltage Measurement... 13:12:29 Voltage Offset Correction: v_off_ini = 2840.225 uV, v_off_fin = 2848.907 uV 13:12:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.692 uVs 13:12:34 I1X Average and RMS of Measurements VT = -91.012 +- 4.660 uVs I1X = 18.203 +- 0.931 uTm 13:12:36 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:12:40 Integrated Voltage Measurement... 13:12:49 Voltage Offset Correction: v_off_ini = 2824.345 uV, v_off_fin = 2817.150 uV 13:12:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.998 uVs 13:12:49 Integrated Voltage Measurement... 13:12:58 Voltage Offset Correction: v_off_ini = 2811.043 uV, v_off_fin = 2829.159 uV 13:12:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.939 uVs 13:12:58 Integrated Voltage Measurement... 13:13:07 Voltage Offset Correction: v_off_ini = 2827.337 uV, v_off_fin = 2821.980 uV 13:13:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.414 uVs 13:13:07 Integrated Voltage Measurement... 13:13:16 Voltage Offset Correction: v_off_ini = 2831.272 uV, v_off_fin = 2845.230 uV 13:13:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.012 uVs 13:13:16 Integrated Voltage Measurement... 13:13:25 Voltage Offset Correction: v_off_ini = 2837.104 uV, v_off_fin = 2807.339 uV 13:13:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.214 uVs 13:13:25 Integrated Voltage Measurement... 13:13:34 Voltage Offset Correction: v_off_ini = 2809.544 uV, v_off_fin = 2811.460 uV 13:13:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.165 uVs 13:13:38 I1Y Average and RMS of Measurements VT = -240.790 +- 4.075 uVs I1Y = -48.158 +- 0.815 uTm 13:13:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:13:44 Integrated Voltage Measurement... 13:13:53 Voltage Offset Correction: v_off_ini = 2833.318 uV, v_off_fin = 2815.287 uV 13:13:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -45.005 uVs 13:13:53 Integrated Voltage Measurement... 13:14:02 Voltage Offset Correction: v_off_ini = 2823.292 uV, v_off_fin = 2830.854 uV 13:14:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.032 uVs 13:14:02 Integrated Voltage Measurement... 13:14:11 Voltage Offset Correction: v_off_ini = 2831.310 uV, v_off_fin = 2814.513 uV 13:14:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.875 uVs 13:14:11 Integrated Voltage Measurement... 13:14:20 Voltage Offset Correction: v_off_ini = 2806.829 uV, v_off_fin = 2835.640 uV 13:14:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.878 uVs 13:14:20 Integrated Voltage Measurement... 13:14:29 Voltage Offset Correction: v_off_ini = 2841.392 uV, v_off_fin = 2833.569 uV 13:14:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.954 uVs 13:14:29 Integrated Voltage Measurement... 13:14:38 Voltage Offset Correction: v_off_ini = 2818.156 uV, v_off_fin = 2831.095 uV 13:14:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.001 uVs 13:14:40 I2X Average and RMS of Measurements VT = -47.624 +- 3.738 uVs I2X = 4.381 +- 0.344 uTm^2 13:14:43 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:14:45 Integrated Voltage Measurement... 13:14:54 Voltage Offset Correction: v_off_ini = 2852.739 uV, v_off_fin = 2837.501 uV 13:14:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.228 uVs 13:14:54 Integrated Voltage Measurement... 13:15:03 Voltage Offset Correction: v_off_ini = 2850.137 uV, v_off_fin = 2851.223 uV 13:15:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 255.640 uVs 13:15:03 Integrated Voltage Measurement... 13:15:12 Voltage Offset Correction: v_off_ini = 2857.135 uV, v_off_fin = 2841.169 uV 13:15:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -287.548 uVs 13:15:12 Integrated Voltage Measurement... 13:15:21 Voltage Offset Correction: v_off_ini = 2826.768 uV, v_off_fin = 2849.896 uV 13:15:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.280 uVs 13:15:21 Integrated Voltage Measurement... 13:15:30 Voltage Offset Correction: v_off_ini = 2835.712 uV, v_off_fin = 2847.616 uV 13:15:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.048 uVs 13:15:30 Integrated Voltage Measurement... 13:15:39 Voltage Offset Correction: v_off_ini = 2857.067 uV, v_off_fin = 2842.690 uV 13:15:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.643 uVs 13:15:42 I2Y Average and RMS of Measurements VT = -268.898 +- 7.408 uVs I2Y = -24.739 +- 0.682 uTm^2 13:15:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:50 Integrated Voltage Measurement... 13:15:59 Voltage Offset Correction: v_off_ini = 2855.015 uV, v_off_fin = 2857.380 uV 13:15:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.853 uVs 13:15:59 Integrated Voltage Measurement... 13:16:08 Voltage Offset Correction: v_off_ini = 2872.175 uV, v_off_fin = 2869.265 uV 13:16:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.056 uVs 13:16:08 Integrated Voltage Measurement... 13:16:17 Voltage Offset Correction: v_off_ini = 2877.874 uV, v_off_fin = 2895.102 uV 13:16:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.250 uVs 13:16:17 Integrated Voltage Measurement... 13:16:26 Voltage Offset Correction: v_off_ini = 2903.269 uV, v_off_fin = 2887.028 uV 13:16:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.602 uVs 13:16:26 Integrated Voltage Measurement... 13:16:35 Voltage Offset Correction: v_off_ini = 2889.592 uV, v_off_fin = 2871.372 uV 13:16:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -99.596 uVs 13:16:35 Integrated Voltage Measurement... 13:16:44 Voltage Offset Correction: v_off_ini = 2888.303 uV, v_off_fin = 2893.947 uV 13:16:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.569 uVs 13:16:48 I1X Average and RMS of Measurements VT = -86.654 +- 15.257 uVs I1X = 17.331 +- 3.051 uTm 13:16:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:16:55 Integrated Voltage Measurement... 13:17:04 Voltage Offset Correction: v_off_ini = 2848.316 uV, v_off_fin = 2831.569 uV 13:17:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.655 uVs 13:17:04 Integrated Voltage Measurement... 13:17:13 Voltage Offset Correction: v_off_ini = 2842.030 uV, v_off_fin = 2862.217 uV 13:17:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 278.565 uVs 13:17:13 Integrated Voltage Measurement... 13:17:22 Voltage Offset Correction: v_off_ini = 2852.125 uV, v_off_fin = 2839.355 uV 13:17:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.336 uVs 13:17:22 Integrated Voltage Measurement... 13:17:31 Voltage Offset Correction: v_off_ini = 2852.384 uV, v_off_fin = 2869.586 uV 13:17:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.061 uVs 13:17:31 Integrated Voltage Measurement... 13:17:40 Voltage Offset Correction: v_off_ini = 2853.138 uV, v_off_fin = 2850.818 uV 13:17:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.386 uVs 13:17:40 Integrated Voltage Measurement... 13:17:49 Voltage Offset Correction: v_off_ini = 2849.880 uV, v_off_fin = 2849.971 uV 13:17:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.265 uVs 13:17:53 I1Y Average and RMS of Measurements VT = -251.711 +- 5.965 uVs I1Y = -50.343 +- 1.194 uTm 13:17:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:17:58 Integrated Voltage Measurement... 13:18:07 Voltage Offset Correction: v_off_ini = 2820.655 uV, v_off_fin = 2845.825 uV 13:18:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.814 uVs 13:18:07 Integrated Voltage Measurement... 13:18:16 Voltage Offset Correction: v_off_ini = 2887.757 uV, v_off_fin = 2858.970 uV 13:18:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.948 uVs 13:18:16 Integrated Voltage Measurement... 13:18:25 Voltage Offset Correction: v_off_ini = 2844.258 uV, v_off_fin = 2833.213 uV 13:18:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.348 uVs 13:18:25 Integrated Voltage Measurement... 13:18:34 Voltage Offset Correction: v_off_ini = 2854.455 uV, v_off_fin = 2849.722 uV 13:18:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.242 uVs 13:18:34 Integrated Voltage Measurement... 13:18:43 Voltage Offset Correction: v_off_ini = 2817.446 uV, v_off_fin = 2803.960 uV 13:18:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.019 uVs 13:18:43 Integrated Voltage Measurement... 13:18:52 Voltage Offset Correction: v_off_ini = 2826.674 uV, v_off_fin = 2828.839 uV 13:18:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.121 uVs 13:18:55 I2X Average and RMS of Measurements VT = -47.582 +- 4.241 uVs I2X = 4.378 +- 0.390 uTm^2 13:18:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:19:00 Integrated Voltage Measurement... 13:19:09 Voltage Offset Correction: v_off_ini = 2838.313 uV, v_off_fin = 2823.012 uV 13:19:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.596 uVs 13:19:09 Integrated Voltage Measurement... 13:19:18 Voltage Offset Correction: v_off_ini = 2837.997 uV, v_off_fin = 2842.687 uV 13:19:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.402 uVs 13:19:18 Integrated Voltage Measurement... 13:19:27 Voltage Offset Correction: v_off_ini = 2827.994 uV, v_off_fin = 2824.836 uV 13:19:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -273.003 uVs 13:19:27 Integrated Voltage Measurement... 13:19:36 Voltage Offset Correction: v_off_ini = 2811.560 uV, v_off_fin = 2820.327 uV 13:19:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.980 uVs 13:19:36 Integrated Voltage Measurement... 13:19:45 Voltage Offset Correction: v_off_ini = 2838.785 uV, v_off_fin = 2836.771 uV 13:19:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.595 uVs 13:19:45 Integrated Voltage Measurement... 13:19:54 Voltage Offset Correction: v_off_ini = 2849.235 uV, v_off_fin = 2837.080 uV 13:19:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.438 uVs 13:19:57 I2Y Average and RMS of Measurements VT = -269.502 +- 3.076 uVs I2Y = -24.794 +- 0.283 uTm^2 13:20:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:20:05 Integrated Voltage Measurement... 13:20:14 Voltage Offset Correction: v_off_ini = 2840.548 uV, v_off_fin = 2809.443 uV 13:20:14 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -100.474 uVs 13:20:14 Integrated Voltage Measurement... 13:20:23 Voltage Offset Correction: v_off_ini = 2816.481 uV, v_off_fin = 2830.866 uV 13:20:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.918 uVs 13:20:23 Integrated Voltage Measurement... 13:20:32 Voltage Offset Correction: v_off_ini = 2834.995 uV, v_off_fin = 2822.792 uV 13:20:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -105.156 uVs 13:20:32 Integrated Voltage Measurement... 13:20:41 Voltage Offset Correction: v_off_ini = 2850.321 uV, v_off_fin = 2841.369 uV 13:20:41 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.780 uVs 13:20:41 Integrated Voltage Measurement... 13:20:50 Voltage Offset Correction: v_off_ini = 2837.208 uV, v_off_fin = 2848.377 uV 13:20:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.684 uVs 13:20:50 Integrated Voltage Measurement... 13:20:59 Voltage Offset Correction: v_off_ini = 2861.828 uV, v_off_fin = 2867.502 uV 13:20:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.683 uVs 13:21:03 I1X Average and RMS of Measurements VT = -82.616 +- 7.408 uVs I1X = 16.525 +- 1.483 uTm 13:21:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:21:10 Integrated Voltage Measurement... 13:21:19 Voltage Offset Correction: v_off_ini = 2869.047 uV, v_off_fin = 2855.699 uV 13:21:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.802 uVs 13:21:19 Integrated Voltage Measurement... 13:21:28 Voltage Offset Correction: v_off_ini = 2850.647 uV, v_off_fin = 2853.705 uV 13:21:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.236 uVs 13:21:28 Integrated Voltage Measurement... 13:21:37 Voltage Offset Correction: v_off_ini = 2850.587 uV, v_off_fin = 2848.410 uV 13:21:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.855 uVs 13:21:37 Integrated Voltage Measurement... 13:21:46 Voltage Offset Correction: v_off_ini = 2856.921 uV, v_off_fin = 2867.102 uV 13:21:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.425 uVs 13:21:46 Integrated Voltage Measurement... 13:21:55 Voltage Offset Correction: v_off_ini = 2861.266 uV, v_off_fin = 2854.575 uV 13:21:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.782 uVs 13:21:55 Integrated Voltage Measurement... 13:22:04 Voltage Offset Correction: v_off_ini = 2852.678 uV, v_off_fin = 2859.575 uV 13:22:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 259.743 uVs 13:22:08 I1Y Average and RMS of Measurements VT = -259.307 +- 5.169 uVs I1Y = -51.861 +- 1.035 uTm 13:22:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:22:13 Integrated Voltage Measurement... 13:22:22 Voltage Offset Correction: v_off_ini = 2849.295 uV, v_off_fin = 2813.964 uV 13:22:22 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = 3.523 uVs 13:22:22 Integrated Voltage Measurement... 13:22:31 Voltage Offset Correction: v_off_ini = 2842.067 uV, v_off_fin = 2845.498 uV 13:22:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.726 uVs 13:22:31 Integrated Voltage Measurement... 13:22:40 Voltage Offset Correction: v_off_ini = 2841.279 uV, v_off_fin = 2834.377 uV 13:22:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.905 uVs 13:22:40 Integrated Voltage Measurement... 13:22:49 Voltage Offset Correction: v_off_ini = 2841.399 uV, v_off_fin = 2867.321 uV 13:22:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.450 uVs 13:22:49 Integrated Voltage Measurement... 13:22:58 Voltage Offset Correction: v_off_ini = 2834.649 uV, v_off_fin = 2809.267 uV 13:22:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.000 uVs 13:22:58 Integrated Voltage Measurement... 13:23:07 Voltage Offset Correction: v_off_ini = 2842.030 uV, v_off_fin = 2847.199 uV 13:23:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.781 uVs 13:23:09 I2X Average and RMS of Measurements VT = -24.890 +- 8.664 uVs I2X = 2.290 +- 0.797 uTm^2 13:23:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:23:15 Integrated Voltage Measurement... 13:23:24 Voltage Offset Correction: v_off_ini = 2823.721 uV, v_off_fin = 2822.328 uV 13:23:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.100 uVs 13:23:24 Integrated Voltage Measurement... 13:23:33 Voltage Offset Correction: v_off_ini = 2832.921 uV, v_off_fin = 2847.664 uV 13:23:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.799 uVs 13:23:33 Integrated Voltage Measurement... 13:23:42 Voltage Offset Correction: v_off_ini = 2832.311 uV, v_off_fin = 2822.825 uV 13:23:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.638 uVs 13:23:42 Integrated Voltage Measurement... 13:23:51 Voltage Offset Correction: v_off_ini = 2821.505 uV, v_off_fin = 2834.717 uV 13:23:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.630 uVs 13:23:51 Integrated Voltage Measurement... 13:24:00 Voltage Offset Correction: v_off_ini = 2835.370 uV, v_off_fin = 2822.759 uV 13:24:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.861 uVs 13:24:00 Integrated Voltage Measurement... 13:24:09 Voltage Offset Correction: v_off_ini = 2851.521 uV, v_off_fin = 2847.387 uV 13:24:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.225 uVs 13:24:11 I2Y Average and RMS of Measurements VT = -276.875 +- 6.656 uVs I2Y = -25.473 +- 0.612 uTm^2 13:24:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:24:19 Integrated Voltage Measurement... 13:24:28 Voltage Offset Correction: v_off_ini = 2852.439 uV, v_off_fin = 2825.460 uV 13:24:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -116.959 uVs 13:24:28 Integrated Voltage Measurement... 13:24:37 Voltage Offset Correction: v_off_ini = 2804.344 uV, v_off_fin = 2794.582 uV 13:24:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.791 uVs 13:24:37 Integrated Voltage Measurement... 13:24:46 Voltage Offset Correction: v_off_ini = 2780.066 uV, v_off_fin = 2785.260 uV 13:24:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -57.141 uVs 13:24:46 Integrated Voltage Measurement... 13:24:55 Voltage Offset Correction: v_off_ini = 2815.333 uV, v_off_fin = 2823.110 uV 13:24:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 125.736 uVs 13:24:55 Integrated Voltage Measurement... 13:25:04 Voltage Offset Correction: v_off_ini = 2856.970 uV, v_off_fin = 2843.608 uV 13:25:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.526 uVs 13:25:04 Integrated Voltage Measurement... 13:25:13 Voltage Offset Correction: v_off_ini = 2839.085 uV, v_off_fin = 2842.539 uV 13:25:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.763 uVs 13:25:18 I1X Average and RMS of Measurements VT = -89.819 +- 1.150 uVs I1X = 17.966 +- 0.230 uTm 13:25:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:25:24 Integrated Voltage Measurement... 13:25:33 Voltage Offset Correction: v_off_ini = 2811.526 uV, v_off_fin = 2823.638 uV 13:25:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -230.851 uVs 13:25:33 Integrated Voltage Measurement... 13:25:42 Voltage Offset Correction: v_off_ini = 2820.340 uV, v_off_fin = 2851.176 uV 13:25:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 257.426 uVs 13:25:42 Integrated Voltage Measurement... 13:25:51 Voltage Offset Correction: v_off_ini = 2822.324 uV, v_off_fin = 2801.362 uV 13:25:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -258.179 uVs 13:25:51 Integrated Voltage Measurement... 13:26:00 Voltage Offset Correction: v_off_ini = 2820.238 uV, v_off_fin = 2823.503 uV 13:26:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.543 uVs 13:26:00 Integrated Voltage Measurement... 13:26:09 Voltage Offset Correction: v_off_ini = 2820.290 uV, v_off_fin = 2804.040 uV 13:26:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.251 uVs 13:26:09 Integrated Voltage Measurement... 13:26:18 Voltage Offset Correction: v_off_ini = 2797.481 uV, v_off_fin = 2823.768 uV 13:26:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.653 uVs 13:26:22 I1Y Average and RMS of Measurements VT = -258.150 +- 10.381 uVs I1Y = -51.628 +- 2.078 uTm 13:26:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:26:28 Integrated Voltage Measurement... 13:26:36 Voltage Offset Correction: v_off_ini = 2823.081 uV, v_off_fin = 2815.033 uV 13:26:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.081 uVs 13:26:37 Integrated Voltage Measurement... 13:26:46 Voltage Offset Correction: v_off_ini = 2816.902 uV, v_off_fin = 2804.628 uV 13:26:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.709 uVs 13:26:46 Integrated Voltage Measurement... 13:26:55 Voltage Offset Correction: v_off_ini = 2796.886 uV, v_off_fin = 2822.366 uV 13:26:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.835 uVs 13:26:55 Integrated Voltage Measurement... 13:27:04 Voltage Offset Correction: v_off_ini = 2806.857 uV, v_off_fin = 2799.644 uV 13:27:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.794 uVs 13:27:04 Integrated Voltage Measurement... 13:27:13 Voltage Offset Correction: v_off_ini = 2797.861 uV, v_off_fin = 2781.635 uV 13:27:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.957 uVs 13:27:13 Integrated Voltage Measurement... 13:27:22 Voltage Offset Correction: v_off_ini = 2812.996 uV, v_off_fin = 2805.380 uV 13:27:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.694 uVs 13:27:24 I2X Average and RMS of Measurements VT = -29.678 +- 3.265 uVs I2X = 2.730 +- 0.300 uTm^2 13:27:27 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:27:29 Integrated Voltage Measurement... 13:27:38 Voltage Offset Correction: v_off_ini = 2814.551 uV, v_off_fin = 2812.673 uV 13:27:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.467 uVs 13:27:38 Integrated Voltage Measurement... 13:27:47 Voltage Offset Correction: v_off_ini = 2824.146 uV, v_off_fin = 2834.846 uV 13:27:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.110 uVs 13:27:47 Integrated Voltage Measurement... 13:27:56 Voltage Offset Correction: v_off_ini = 2844.183 uV, v_off_fin = 2844.680 uV 13:27:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.326 uVs 13:27:56 Integrated Voltage Measurement... 13:28:05 Voltage Offset Correction: v_off_ini = 2861.564 uV, v_off_fin = 2853.472 uV 13:28:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 285.999 uVs 13:28:05 Integrated Voltage Measurement... 13:28:14 Voltage Offset Correction: v_off_ini = 2848.831 uV, v_off_fin = 2835.678 uV 13:28:14 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -263.778 uVs 13:28:14 Integrated Voltage Measurement... 13:28:23 Voltage Offset Correction: v_off_ini = 2820.166 uV, v_off_fin = 2858.011 uV 13:28:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.219 uVs 13:28:26 I2Y Average and RMS of Measurements VT = -275.650 +- 6.734 uVs I2Y = -25.360 +- 0.619 uTm^2 13:28:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:28:46 Integrated Voltage Measurement... 13:28:55 Voltage Offset Correction: v_off_ini = 2834.256 uV, v_off_fin = 2833.055 uV 13:28:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.040 uVs 13:28:55 Integrated Voltage Measurement... 13:29:04 Voltage Offset Correction: v_off_ini = 2808.756 uV, v_off_fin = 2815.147 uV 13:29:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 99.493 uVs 13:29:04 Integrated Voltage Measurement... 13:29:13 Voltage Offset Correction: v_off_ini = 2812.568 uV, v_off_fin = 2818.446 uV 13:29:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.818 uVs 13:29:13 Integrated Voltage Measurement... 13:29:22 Voltage Offset Correction: v_off_ini = 2800.586 uV, v_off_fin = 2804.263 uV 13:29:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.474 uVs 13:29:22 Integrated Voltage Measurement... 13:29:31 Voltage Offset Correction: v_off_ini = 2820.242 uV, v_off_fin = 2811.623 uV 13:29:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -106.238 uVs 13:29:31 Integrated Voltage Measurement... 13:29:40 Voltage Offset Correction: v_off_ini = 2827.655 uV, v_off_fin = 2810.678 uV 13:29:40 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 92.788 uVs 13:29:44 I1X Average and RMS of Measurements VT = -108.142 +- 6.485 uVs I1X = 21.630 +- 1.296 uTm 13:29:47 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:29:51 Integrated Voltage Measurement... 13:30:00 Voltage Offset Correction: v_off_ini = 2796.647 uV, v_off_fin = 2803.442 uV 13:30:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.608 uVs 13:30:00 Integrated Voltage Measurement... 13:30:09 Voltage Offset Correction: v_off_ini = 2829.568 uV, v_off_fin = 2824.186 uV 13:30:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.618 uVs 13:30:09 Integrated Voltage Measurement... 13:30:18 Voltage Offset Correction: v_off_ini = 2807.809 uV, v_off_fin = 2806.813 uV 13:30:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.638 uVs 13:30:18 Integrated Voltage Measurement... 13:30:27 Voltage Offset Correction: v_off_ini = 2829.158 uV, v_off_fin = 2820.425 uV 13:30:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.003 uVs 13:30:27 Integrated Voltage Measurement... 13:30:36 Voltage Offset Correction: v_off_ini = 2820.748 uV, v_off_fin = 2804.820 uV 13:30:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.989 uVs 13:30:36 Integrated Voltage Measurement... 13:30:45 Voltage Offset Correction: v_off_ini = 2840.885 uV, v_off_fin = 2834.212 uV 13:30:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.433 uVs 13:30:49 I1Y Average and RMS of Measurements VT = -214.382 +- 3.872 uVs I1Y = -42.876 +- 0.774 uTm 13:30:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:30:57 Integrated Voltage Measurement... 13:31:05 Voltage Offset Correction: v_off_ini = 2811.668 uV, v_off_fin = 2809.320 uV 13:31:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.149 uVs 13:31:06 Integrated Voltage Measurement... 13:31:15 Voltage Offset Correction: v_off_ini = 2816.729 uV, v_off_fin = 2817.954 uV 13:31:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.912 uVs 13:31:15 Integrated Voltage Measurement... 13:31:24 Voltage Offset Correction: v_off_ini = 2813.113 uV, v_off_fin = 2796.632 uV 13:31:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.363 uVs 13:31:24 Integrated Voltage Measurement... 13:31:33 Voltage Offset Correction: v_off_ini = 2799.387 uV, v_off_fin = 2815.166 uV 13:31:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.273 uVs 13:31:33 Integrated Voltage Measurement... 13:31:42 Voltage Offset Correction: v_off_ini = 2816.764 uV, v_off_fin = 2808.625 uV 13:31:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.445 uVs 13:31:42 Integrated Voltage Measurement... 13:31:51 Voltage Offset Correction: v_off_ini = 2824.204 uV, v_off_fin = 2842.674 uV 13:31:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.724 uVs 13:31:53 I2X Average and RMS of Measurements VT = -78.478 +- 4.237 uVs I2X = 7.220 +- 0.390 uTm^2 13:31:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:32:01 Integrated Voltage Measurement... 13:32:10 Voltage Offset Correction: v_off_ini = 2814.521 uV, v_off_fin = 2794.359 uV 13:32:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.479 uVs 13:32:10 Integrated Voltage Measurement... 13:32:19 Voltage Offset Correction: v_off_ini = 2788.426 uV, v_off_fin = 2766.989 uV 13:32:19 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 211.732 uVs 13:32:19 Integrated Voltage Measurement... 13:32:28 Voltage Offset Correction: v_off_ini = 2799.143 uV, v_off_fin = 2816.923 uV 13:32:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.326 uVs 13:32:28 Integrated Voltage Measurement... 13:32:37 Voltage Offset Correction: v_off_ini = 2811.253 uV, v_off_fin = 2812.104 uV 13:32:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.605 uVs 13:32:37 Integrated Voltage Measurement... 13:32:46 Voltage Offset Correction: v_off_ini = 2796.637 uV, v_off_fin = 2796.366 uV 13:32:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.635 uVs 13:32:46 Integrated Voltage Measurement... 13:32:55 Voltage Offset Correction: v_off_ini = 2784.820 uV, v_off_fin = 2780.332 uV 13:32:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.869 uVs 13:32:57 I2Y Average and RMS of Measurements VT = -222.608 +- 7.329 uVs I2Y = -20.480 +- 0.674 uTm^2 13:33:02 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:33:06 Integrated Voltage Measurement... 13:33:15 Voltage Offset Correction: v_off_ini = 2822.681 uV, v_off_fin = 2813.650 uV 13:33:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -110.035 uVs 13:33:15 Integrated Voltage Measurement... 13:33:24 Voltage Offset Correction: v_off_ini = 2795.070 uV, v_off_fin = 2818.939 uV 13:33:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.521 uVs 13:33:24 Integrated Voltage Measurement... 13:33:33 Voltage Offset Correction: v_off_ini = 2830.642 uV, v_off_fin = 2839.389 uV 13:33:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -81.760 uVs 13:33:33 Integrated Voltage Measurement... 13:33:42 Voltage Offset Correction: v_off_ini = 2830.003 uV, v_off_fin = 2789.632 uV 13:33:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 90.197 uVs 13:33:42 Integrated Voltage Measurement... 13:33:51 Voltage Offset Correction: v_off_ini = 2786.477 uV, v_off_fin = 2795.048 uV 13:33:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.479 uVs 13:33:51 Integrated Voltage Measurement... 13:34:00 Voltage Offset Correction: v_off_ini = 2794.034 uV, v_off_fin = 2782.034 uV 13:34:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.698 uVs 13:34:04 I1X Average and RMS of Measurements VT = -97.948 +- 8.597 uVs I1X = 19.591 +- 1.721 uTm 13:34:07 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:34:11 Integrated Voltage Measurement... 13:34:20 Voltage Offset Correction: v_off_ini = 2813.930 uV, v_off_fin = 2819.329 uV 13:34:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.748 uVs 13:34:20 Integrated Voltage Measurement... 13:34:29 Voltage Offset Correction: v_off_ini = 2829.673 uV, v_off_fin = 2841.514 uV 13:34:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.238 uVs 13:34:29 Integrated Voltage Measurement... 13:34:38 Voltage Offset Correction: v_off_ini = 2811.509 uV, v_off_fin = 2816.236 uV 13:34:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.167 uVs 13:34:38 Integrated Voltage Measurement... 13:34:47 Voltage Offset Correction: v_off_ini = 2836.245 uV, v_off_fin = 2833.312 uV 13:34:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.089 uVs 13:34:47 Integrated Voltage Measurement... 13:34:56 Voltage Offset Correction: v_off_ini = 2834.472 uV, v_off_fin = 2820.326 uV 13:34:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.536 uVs 13:34:56 Integrated Voltage Measurement... 13:35:05 Voltage Offset Correction: v_off_ini = 2846.935 uV, v_off_fin = 2853.739 uV 13:35:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.323 uVs 13:35:09 I1Y Average and RMS of Measurements VT = -236.684 +- 4.944 uVs I1Y = -47.337 +- 0.989 uTm 13:35:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:35:17 Integrated Voltage Measurement... 13:35:26 Voltage Offset Correction: v_off_ini = 2834.259 uV, v_off_fin = 2821.892 uV 13:35:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -49.426 uVs 13:35:26 Integrated Voltage Measurement... 13:35:35 Voltage Offset Correction: v_off_ini = 2827.185 uV, v_off_fin = 2845.179 uV 13:35:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.968 uVs 13:35:35 Integrated Voltage Measurement... 13:35:44 Voltage Offset Correction: v_off_ini = 2843.304 uV, v_off_fin = 2834.075 uV 13:35:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.363 uVs 13:35:44 Integrated Voltage Measurement... 13:35:53 Voltage Offset Correction: v_off_ini = 2847.996 uV, v_off_fin = 2869.921 uV 13:35:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.724 uVs 13:35:53 Integrated Voltage Measurement... 13:36:02 Voltage Offset Correction: v_off_ini = 2841.289 uV, v_off_fin = 2841.175 uV 13:36:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.493 uVs 13:36:02 Integrated Voltage Measurement... 13:36:11 Voltage Offset Correction: v_off_ini = 2839.376 uV, v_off_fin = 2840.888 uV 13:36:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.800 uVs 13:36:13 I2X Average and RMS of Measurements VT = -66.462 +- 11.919 uVs I2X = 6.115 +- 1.097 uTm^2 13:36:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:36:21 Integrated Voltage Measurement... 13:36:30 Voltage Offset Correction: v_off_ini = 2845.471 uV, v_off_fin = 2850.851 uV 13:36:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.828 uVs 13:36:30 Integrated Voltage Measurement... 13:36:39 Voltage Offset Correction: v_off_ini = 2835.196 uV, v_off_fin = 2845.749 uV 13:36:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.314 uVs 13:36:39 Integrated Voltage Measurement... 13:36:48 Voltage Offset Correction: v_off_ini = 2842.455 uV, v_off_fin = 2825.588 uV 13:36:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.139 uVs 13:36:48 Integrated Voltage Measurement... 13:36:57 Voltage Offset Correction: v_off_ini = 2840.073 uV, v_off_fin = 2839.727 uV 13:36:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.844 uVs 13:36:57 Integrated Voltage Measurement... 13:37:06 Voltage Offset Correction: v_off_ini = 2856.946 uV, v_off_fin = 2844.080 uV 13:37:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.650 uVs 13:37:06 Integrated Voltage Measurement... 13:37:15 Voltage Offset Correction: v_off_ini = 2848.457 uV, v_off_fin = 2852.917 uV 13:37:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.964 uVs 13:37:18 I2Y Average and RMS of Measurements VT = -234.957 +- 4.840 uVs I2Y = -21.616 +- 0.445 uTm^2 13:37:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:37:26 Integrated Voltage Measurement... 13:37:35 Voltage Offset Correction: v_off_ini = 2855.658 uV, v_off_fin = 2840.746 uV 13:37:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.100 uVs 13:37:35 Integrated Voltage Measurement... 13:37:44 Voltage Offset Correction: v_off_ini = 2854.639 uV, v_off_fin = 2843.461 uV 13:37:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.042 uVs 13:37:44 Integrated Voltage Measurement... 13:37:53 Voltage Offset Correction: v_off_ini = 2843.917 uV, v_off_fin = 2822.486 uV 13:37:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -105.841 uVs 13:37:53 Integrated Voltage Measurement... 13:38:02 Voltage Offset Correction: v_off_ini = 2826.071 uV, v_off_fin = 2826.162 uV 13:38:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 103.559 uVs 13:38:02 Integrated Voltage Measurement... 13:38:11 Voltage Offset Correction: v_off_ini = 2805.843 uV, v_off_fin = 2817.339 uV 13:38:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.130 uVs 13:38:11 Integrated Voltage Measurement... 13:38:20 Voltage Offset Correction: v_off_ini = 2843.005 uV, v_off_fin = 2857.233 uV 13:38:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 104.197 uVs 13:38:25 I1X Average and RMS of Measurements VT = -104.978 +- 3.234 uVs I1X = 20.997 +- 0.646 uTm 13:38:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:38:31 Integrated Voltage Measurement... 13:38:40 Voltage Offset Correction: v_off_ini = 2840.680 uV, v_off_fin = 2837.175 uV 13:38:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.370 uVs 13:38:40 Integrated Voltage Measurement... 13:38:49 Voltage Offset Correction: v_off_ini = 2829.042 uV, v_off_fin = 2851.290 uV 13:38:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.038 uVs 13:38:49 Integrated Voltage Measurement... 13:38:58 Voltage Offset Correction: v_off_ini = 2828.062 uV, v_off_fin = 2829.221 uV 13:38:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.877 uVs 13:38:58 Integrated Voltage Measurement... 13:39:07 Voltage Offset Correction: v_off_ini = 2867.055 uV, v_off_fin = 2871.088 uV 13:39:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.481 uVs 13:39:07 Integrated Voltage Measurement... 13:39:16 Voltage Offset Correction: v_off_ini = 2845.038 uV, v_off_fin = 2830.333 uV 13:39:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -233.090 uVs 13:39:16 Integrated Voltage Measurement... 13:39:25 Voltage Offset Correction: v_off_ini = 2853.881 uV, v_off_fin = 2858.078 uV 13:39:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.622 uVs 13:39:30 I1Y Average and RMS of Measurements VT = -240.246 +- 5.816 uVs I1Y = -48.049 +- 1.163 uTm 13:39:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:39:37 Integrated Voltage Measurement... 13:39:46 Voltage Offset Correction: v_off_ini = 2831.246 uV, v_off_fin = 2848.491 uV 13:39:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.022 uVs 13:39:46 Integrated Voltage Measurement... 13:39:55 Voltage Offset Correction: v_off_ini = 2839.638 uV, v_off_fin = 2847.331 uV 13:39:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.885 uVs 13:39:55 Integrated Voltage Measurement... 13:40:04 Voltage Offset Correction: v_off_ini = 2825.501 uV, v_off_fin = 2820.104 uV 13:40:04 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -62.654 uVs 13:40:04 Integrated Voltage Measurement... 13:40:13 Voltage Offset Correction: v_off_ini = 2836.508 uV, v_off_fin = 2834.137 uV 13:40:13 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 54.369 uVs 13:40:13 Integrated Voltage Measurement... 13:40:22 Voltage Offset Correction: v_off_ini = 2811.635 uV, v_off_fin = 2810.977 uV 13:40:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.123 uVs 13:40:22 Integrated Voltage Measurement... 13:40:31 Voltage Offset Correction: v_off_ini = 2795.743 uV, v_off_fin = 2804.544 uV 13:40:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.112 uVs 13:40:34 I2X Average and RMS of Measurements VT = -56.861 +- 1.953 uVs I2X = 5.231 +- 0.180 uTm^2 13:40:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:40:41 Integrated Voltage Measurement... 13:40:50 Voltage Offset Correction: v_off_ini = 2790.320 uV, v_off_fin = 2810.070 uV 13:40:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.606 uVs 13:40:50 Integrated Voltage Measurement... 13:40:59 Voltage Offset Correction: v_off_ini = 2826.539 uV, v_off_fin = 2822.010 uV 13:40:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.208 uVs 13:40:59 Integrated Voltage Measurement... 13:41:08 Voltage Offset Correction: v_off_ini = 2798.211 uV, v_off_fin = 2787.228 uV 13:41:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.445 uVs 13:41:09 Integrated Voltage Measurement... 13:41:17 Voltage Offset Correction: v_off_ini = 2814.912 uV, v_off_fin = 2807.513 uV 13:41:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 273.285 uVs 13:41:18 Integrated Voltage Measurement... 13:41:27 Voltage Offset Correction: v_off_ini = 2801.021 uV, v_off_fin = 2811.794 uV 13:41:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -291.957 uVs 13:41:27 Integrated Voltage Measurement... 13:41:36 Voltage Offset Correction: v_off_ini = 2812.953 uV, v_off_fin = 2779.183 uV 13:41:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 261.625 uVs 13:41:38 I2Y Average and RMS of Measurements VT = -267.354 +- 7.513 uVs I2Y = -24.597 +- 0.692 uTm^2 13:41:43 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:41:47 Integrated Voltage Measurement... 13:41:56 Voltage Offset Correction: v_off_ini = 2797.474 uV, v_off_fin = 2795.491 uV 13:41:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.656 uVs 13:41:56 Integrated Voltage Measurement... 13:42:05 Voltage Offset Correction: v_off_ini = 2809.711 uV, v_off_fin = 2793.506 uV 13:42:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 110.789 uVs 13:42:05 Integrated Voltage Measurement... 13:42:14 Voltage Offset Correction: v_off_ini = 2781.192 uV, v_off_fin = 2789.124 uV 13:42:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.268 uVs 13:42:14 Integrated Voltage Measurement... 13:42:23 Voltage Offset Correction: v_off_ini = 2794.935 uV, v_off_fin = 2803.825 uV 13:42:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 93.625 uVs 13:42:23 Integrated Voltage Measurement... 13:42:32 Voltage Offset Correction: v_off_ini = 2808.728 uV, v_off_fin = 2804.113 uV 13:42:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.592 uVs 13:42:32 Integrated Voltage Measurement... 13:42:41 Voltage Offset Correction: v_off_ini = 2808.531 uV, v_off_fin = 2785.272 uV 13:42:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 154.355 uVs 13:42:45 I1X Average and RMS of Measurements VT = -127.048 +- 8.925 uVs I1X = 25.410 +- 1.785 uTm 13:42:48 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:42:52 Integrated Voltage Measurement... 13:43:01 Voltage Offset Correction: v_off_ini = 2778.379 uV, v_off_fin = 2780.081 uV 13:43:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -271.633 uVs 13:43:01 Integrated Voltage Measurement... 13:43:10 Voltage Offset Correction: v_off_ini = 2804.467 uV, v_off_fin = 2818.617 uV 13:43:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.625 uVs 13:43:10 Integrated Voltage Measurement... 13:43:19 Voltage Offset Correction: v_off_ini = 2789.621 uV, v_off_fin = 2777.733 uV 13:43:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.856 uVs 13:43:19 Integrated Voltage Measurement... 13:43:28 Voltage Offset Correction: v_off_ini = 2792.354 uV, v_off_fin = 2791.875 uV 13:43:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.146 uVs 13:43:28 Integrated Voltage Measurement... 13:43:37 Voltage Offset Correction: v_off_ini = 2785.133 uV, v_off_fin = 2785.504 uV 13:43:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.189 uVs 13:43:37 Integrated Voltage Measurement... 13:43:46 Voltage Offset Correction: v_off_ini = 2785.698 uV, v_off_fin = 2814.687 uV 13:43:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.141 uVs 13:43:50 I1Y Average and RMS of Measurements VT = -248.265 +- 9.377 uVs I1Y = -49.654 +- 1.876 uTm 13:43:55 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:43:58 Integrated Voltage Measurement... 13:44:07 Voltage Offset Correction: v_off_ini = 2793.082 uV, v_off_fin = 2785.533 uV 13:44:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -93.071 uVs 13:44:07 Integrated Voltage Measurement... 13:44:16 Voltage Offset Correction: v_off_ini = 2781.901 uV, v_off_fin = 2792.812 uV 13:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.264 uVs 13:44:16 Integrated Voltage Measurement... 13:44:25 Voltage Offset Correction: v_off_ini = 2807.447 uV, v_off_fin = 2780.265 uV 13:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.374 uVs 13:44:25 Integrated Voltage Measurement... 13:44:34 Voltage Offset Correction: v_off_ini = 2782.446 uV, v_off_fin = 2793.730 uV 13:44:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.090 uVs 13:44:34 Integrated Voltage Measurement... 13:44:43 Voltage Offset Correction: v_off_ini = 2792.228 uV, v_off_fin = 2781.601 uV 13:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.283 uVs 13:44:43 Integrated Voltage Measurement... 13:44:52 Voltage Offset Correction: v_off_ini = 2786.562 uV, v_off_fin = 2791.305 uV 13:44:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.737 uVs 13:44:54 I2X Average and RMS of Measurements VT = -71.803 +- 7.751 uVs I2X = 6.606 +- 0.713 uTm^2 13:44:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:45:02 Integrated Voltage Measurement... 13:45:11 Voltage Offset Correction: v_off_ini = 2768.257 uV, v_off_fin = 2767.805 uV 13:45:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.899 uVs 13:45:11 Integrated Voltage Measurement... 13:45:20 Voltage Offset Correction: v_off_ini = 2748.953 uV, v_off_fin = 2790.994 uV 13:45:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.089 uVs 13:45:20 Integrated Voltage Measurement... 13:45:29 Voltage Offset Correction: v_off_ini = 2787.313 uV, v_off_fin = 2780.590 uV 13:45:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.480 uVs 13:45:29 Integrated Voltage Measurement... 13:45:38 Voltage Offset Correction: v_off_ini = 2783.964 uV, v_off_fin = 2794.662 uV 13:45:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.134 uVs 13:45:38 Integrated Voltage Measurement... 13:45:47 Voltage Offset Correction: v_off_ini = 2776.874 uV, v_off_fin = 2775.598 uV 13:45:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.785 uVs 13:45:47 Integrated Voltage Measurement... 13:45:56 Voltage Offset Correction: v_off_ini = 2761.066 uV, v_off_fin = 2752.500 uV 13:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.070 uVs 13:45:58 I2Y Average and RMS of Measurements VT = -257.743 +- 7.483 uVs I2Y = -23.712 +- 0.688 uTm^2 13:46:03 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:46:07 Integrated Voltage Measurement... 13:46:16 Voltage Offset Correction: v_off_ini = 2777.199 uV, v_off_fin = 2773.779 uV 13:46:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.299 uVs 13:46:16 Integrated Voltage Measurement... 13:46:25 Voltage Offset Correction: v_off_ini = 2779.750 uV, v_off_fin = 2800.994 uV 13:46:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.706 uVs 13:46:25 Integrated Voltage Measurement... 13:46:34 Voltage Offset Correction: v_off_ini = 2827.728 uV, v_off_fin = 2815.467 uV 13:46:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.181 uVs 13:46:34 Integrated Voltage Measurement... 13:46:43 Voltage Offset Correction: v_off_ini = 2804.544 uV, v_off_fin = 2777.072 uV 13:46:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 129.984 uVs 13:46:43 Integrated Voltage Measurement... 13:46:52 Voltage Offset Correction: v_off_ini = 2799.313 uV, v_off_fin = 2809.019 uV 13:46:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.468 uVs 13:46:52 Integrated Voltage Measurement... 13:47:01 Voltage Offset Correction: v_off_ini = 2793.991 uV, v_off_fin = 2804.539 uV 13:47:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.070 uVs 13:47:06 I1X Average and RMS of Measurements VT = -139.118 +- 3.751 uVs I1X = 27.824 +- 0.750 uTm 13:47:08 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:47:12 Integrated Voltage Measurement... 13:47:21 Voltage Offset Correction: v_off_ini = 2796.123 uV, v_off_fin = 2821.442 uV 13:47:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.839 uVs 13:47:21 Integrated Voltage Measurement... 13:47:30 Voltage Offset Correction: v_off_ini = 2819.775 uV, v_off_fin = 2841.632 uV 13:47:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.430 uVs 13:47:30 Integrated Voltage Measurement... 13:47:39 Voltage Offset Correction: v_off_ini = 2823.510 uV, v_off_fin = 2825.310 uV 13:47:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.093 uVs 13:47:39 Integrated Voltage Measurement... 13:47:48 Voltage Offset Correction: v_off_ini = 2844.661 uV, v_off_fin = 2860.130 uV 13:47:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.976 uVs 13:47:48 Integrated Voltage Measurement... 13:47:57 Voltage Offset Correction: v_off_ini = 2828.928 uV, v_off_fin = 2793.304 uV 13:47:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.971 uVs 13:47:57 Integrated Voltage Measurement... 13:48:06 Voltage Offset Correction: v_off_ini = 2830.339 uV, v_off_fin = 2845.131 uV 13:48:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 258.304 uVs 13:48:10 I1Y Average and RMS of Measurements VT = -250.436 +- 9.504 uVs I1Y = -50.087 +- 1.901 uTm 13:48:15 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:48:18 Integrated Voltage Measurement... 13:48:27 Voltage Offset Correction: v_off_ini = 2774.177 uV, v_off_fin = 2796.232 uV 13:48:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.752 uVs 13:48:27 Integrated Voltage Measurement... 13:48:36 Voltage Offset Correction: v_off_ini = 2784.046 uV, v_off_fin = 2796.359 uV 13:48:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.478 uVs 13:48:36 Integrated Voltage Measurement... 13:48:45 Voltage Offset Correction: v_off_ini = 2801.183 uV, v_off_fin = 2790.261 uV 13:48:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.087 uVs 13:48:45 Integrated Voltage Measurement... 13:48:54 Voltage Offset Correction: v_off_ini = 2780.781 uV, v_off_fin = 2789.834 uV 13:48:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.530 uVs 13:48:54 Integrated Voltage Measurement... 13:49:03 Voltage Offset Correction: v_off_ini = 2790.196 uV, v_off_fin = 2778.462 uV 13:49:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.123 uVs 13:49:03 Integrated Voltage Measurement... 13:49:12 Voltage Offset Correction: v_off_ini = 2780.517 uV, v_off_fin = 2808.408 uV 13:49:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.664 uVs 13:49:15 I2X Average and RMS of Measurements VT = -74.772 +- 12.066 uVs I2X = 6.879 +- 1.110 uTm^2 13:49:20 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:49:22 Integrated Voltage Measurement... 13:49:31 Voltage Offset Correction: v_off_ini = 2794.976 uV, v_off_fin = 2784.727 uV 13:49:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -248.860 uVs 13:49:31 Integrated Voltage Measurement... 13:49:40 Voltage Offset Correction: v_off_ini = 2761.193 uV, v_off_fin = 2771.606 uV 13:49:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.885 uVs 13:49:40 Integrated Voltage Measurement... 13:49:49 Voltage Offset Correction: v_off_ini = 2784.854 uV, v_off_fin = 2776.065 uV 13:49:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.767 uVs 13:49:49 Integrated Voltage Measurement... 13:49:58 Voltage Offset Correction: v_off_ini = 2777.248 uV, v_off_fin = 2785.310 uV 13:49:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.339 uVs 13:49:58 Integrated Voltage Measurement... 13:50:07 Voltage Offset Correction: v_off_ini = 2794.986 uV, v_off_fin = 2773.878 uV 13:50:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.884 uVs 13:50:07 Integrated Voltage Measurement... 13:50:16 Voltage Offset Correction: v_off_ini = 2802.004 uV, v_off_fin = 2791.239 uV 13:50:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.762 uVs 13:50:19 I2Y Average and RMS of Measurements VT = -261.083 +- 5.453 uVs I2Y = -24.020 +- 0.502 uTm^2 13:50:26 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:50:31 Integrated Voltage Measurement... 13:50:40 Voltage Offset Correction: v_off_ini = 2822.165 uV, v_off_fin = 2797.078 uV 13:50:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -111.480 uVs 13:50:40 Integrated Voltage Measurement... 13:50:49 Voltage Offset Correction: v_off_ini = 2770.115 uV, v_off_fin = 2780.658 uV 13:50:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 117.405 uVs 13:50:49 Integrated Voltage Measurement... 13:50:58 Voltage Offset Correction: v_off_ini = 2790.349 uV, v_off_fin = 2797.779 uV 13:50:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.955 uVs 13:50:58 Integrated Voltage Measurement... 13:51:07 Voltage Offset Correction: v_off_ini = 2791.001 uV, v_off_fin = 2793.433 uV 13:51:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.236 uVs 13:51:07 Integrated Voltage Measurement... 13:51:16 Voltage Offset Correction: v_off_ini = 2775.272 uV, v_off_fin = 2768.830 uV 13:51:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.538 uVs 13:51:16 Integrated Voltage Measurement... 13:51:25 Voltage Offset Correction: v_off_ini = 2771.931 uV, v_off_fin = 2780.755 uV 13:51:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.941 uVs 13:51:29 I1X Average and RMS of Measurements VT = -116.093 +- 3.994 uVs I1X = 23.220 +- 0.798 uTm 13:51:31 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:51:36 Integrated Voltage Measurement... 13:51:45 Voltage Offset Correction: v_off_ini = 2781.950 uV, v_off_fin = 2748.361 uV 13:51:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.150 uVs 13:51:45 Integrated Voltage Measurement... 13:51:54 Voltage Offset Correction: v_off_ini = 2750.089 uV, v_off_fin = 2762.750 uV 13:51:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.823 uVs 13:51:54 Integrated Voltage Measurement... 13:52:03 Voltage Offset Correction: v_off_ini = 2768.737 uV, v_off_fin = 2755.220 uV 13:52:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.525 uVs 13:52:03 Integrated Voltage Measurement... 13:52:12 Voltage Offset Correction: v_off_ini = 2755.170 uV, v_off_fin = 2755.390 uV 13:52:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.550 uVs 13:52:12 Integrated Voltage Measurement... 13:52:21 Voltage Offset Correction: v_off_ini = 2754.957 uV, v_off_fin = 2745.057 uV 13:52:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.711 uVs 13:52:21 Integrated Voltage Measurement... 13:52:30 Voltage Offset Correction: v_off_ini = 2765.582 uV, v_off_fin = 2759.664 uV 13:52:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.816 uVs 13:52:34 I1Y Average and RMS of Measurements VT = -233.929 +- 6.978 uVs I1Y = -46.786 +- 1.396 uTm 13:52:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:52:39 Integrated Voltage Measurement... 13:52:48 Voltage Offset Correction: v_off_ini = 2758.446 uV, v_off_fin = 2778.094 uV 13:52:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.826 uVs 13:52:48 Integrated Voltage Measurement... 13:52:57 Voltage Offset Correction: v_off_ini = 2769.775 uV, v_off_fin = 2779.864 uV 13:52:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.110 uVs 13:52:57 Integrated Voltage Measurement... 13:53:06 Voltage Offset Correction: v_off_ini = 2766.092 uV, v_off_fin = 2767.574 uV 13:53:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -73.167 uVs 13:53:06 Integrated Voltage Measurement... 13:53:15 Voltage Offset Correction: v_off_ini = 2768.125 uV, v_off_fin = 2774.233 uV 13:53:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.631 uVs 13:53:15 Integrated Voltage Measurement... 13:53:24 Voltage Offset Correction: v_off_ini = 2785.933 uV, v_off_fin = 2748.116 uV 13:53:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.557 uVs 13:53:24 Integrated Voltage Measurement... 13:53:33 Voltage Offset Correction: v_off_ini = 2772.091 uV, v_off_fin = 2799.610 uV 13:53:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.280 uVs 13:53:36 I2X Average and RMS of Measurements VT = -84.928 +- 11.834 uVs I2X = 7.813 +- 1.089 uTm^2 13:53:38 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:53:41 Integrated Voltage Measurement... 13:53:50 Voltage Offset Correction: v_off_ini = 2774.112 uV, v_off_fin = 2782.957 uV 13:53:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.885 uVs 13:53:50 Integrated Voltage Measurement... 13:53:59 Voltage Offset Correction: v_off_ini = 2793.535 uV, v_off_fin = 2777.930 uV 13:53:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.302 uVs 13:53:59 Integrated Voltage Measurement... 13:54:08 Voltage Offset Correction: v_off_ini = 2779.872 uV, v_off_fin = 2777.662 uV 13:54:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.857 uVs 13:54:08 Integrated Voltage Measurement... 13:54:17 Voltage Offset Correction: v_off_ini = 2790.152 uV, v_off_fin = 2786.906 uV 13:54:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.040 uVs 13:54:17 Integrated Voltage Measurement... 13:54:26 Voltage Offset Correction: v_off_ini = 2781.276 uV, v_off_fin = 2808.556 uV 13:54:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -265.714 uVs 13:54:26 Integrated Voltage Measurement... 13:54:35 Voltage Offset Correction: v_off_ini = 2812.639 uV, v_off_fin = 2790.701 uV 13:54:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.613 uVs 13:54:37 I2Y Average and RMS of Measurements VT = -248.902 +- 3.874 uVs I2Y = -22.899 +- 0.356 uTm^2 13:54:41 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:54:45 Integrated Voltage Measurement... 13:54:54 Voltage Offset Correction: v_off_ini = 2831.379 uV, v_off_fin = 2797.562 uV 13:54:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -151.216 uVs 13:54:54 Integrated Voltage Measurement... 13:55:03 Voltage Offset Correction: v_off_ini = 2837.238 uV, v_off_fin = 2813.371 uV 13:55:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.683 uVs 13:55:03 Integrated Voltage Measurement... 13:55:12 Voltage Offset Correction: v_off_ini = 2815.106 uV, v_off_fin = 2816.509 uV 13:55:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.202 uVs 13:55:12 Integrated Voltage Measurement... 13:55:21 Voltage Offset Correction: v_off_ini = 2819.137 uV, v_off_fin = 2811.536 uV 13:55:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.217 uVs 13:55:21 Integrated Voltage Measurement... 13:55:30 Voltage Offset Correction: v_off_ini = 2801.902 uV, v_off_fin = 2801.062 uV 13:55:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.134 uVs 13:55:30 Integrated Voltage Measurement... 13:55:39 Voltage Offset Correction: v_off_ini = 2771.253 uV, v_off_fin = 2791.061 uV 13:55:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 122.480 uVs 13:55:44 I1X Average and RMS of Measurements VT = -117.989 +- 4.485 uVs I1X = 23.599 +- 0.896 uTm 13:55:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:55:50 Integrated Voltage Measurement... 13:55:59 Voltage Offset Correction: v_off_ini = 2771.419 uV, v_off_fin = 2784.403 uV 13:55:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.696 uVs 13:55:59 Integrated Voltage Measurement... 13:56:08 Voltage Offset Correction: v_off_ini = 2802.436 uV, v_off_fin = 2789.989 uV 13:56:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.291 uVs 13:56:08 Integrated Voltage Measurement... 13:56:17 Voltage Offset Correction: v_off_ini = 2793.149 uV, v_off_fin = 2790.672 uV 13:56:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.323 uVs 13:56:17 Integrated Voltage Measurement... 13:56:26 Voltage Offset Correction: v_off_ini = 2784.036 uV, v_off_fin = 2797.494 uV 13:56:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.460 uVs 13:56:26 Integrated Voltage Measurement... 13:56:35 Voltage Offset Correction: v_off_ini = 2792.214 uV, v_off_fin = 2792.747 uV 13:56:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.427 uVs 13:56:35 Integrated Voltage Measurement... 13:56:44 Voltage Offset Correction: v_off_ini = 2797.350 uV, v_off_fin = 2796.575 uV 13:56:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.109 uVs 13:56:49 I1Y Average and RMS of Measurements VT = -237.551 +- 1.809 uVs I1Y = -47.510 +- 0.362 uTm 13:56:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:56:54 Integrated Voltage Measurement... 13:57:03 Voltage Offset Correction: v_off_ini = 2785.701 uV, v_off_fin = 2789.528 uV 13:57:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.958 uVs 13:57:03 Integrated Voltage Measurement... 13:57:12 Voltage Offset Correction: v_off_ini = 2804.656 uV, v_off_fin = 2793.644 uV 13:57:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.052 uVs 13:57:12 Integrated Voltage Measurement... 13:57:21 Voltage Offset Correction: v_off_ini = 2771.025 uV, v_off_fin = 2772.678 uV 13:57:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.019 uVs 13:57:21 Integrated Voltage Measurement... 13:57:30 Voltage Offset Correction: v_off_ini = 2779.020 uV, v_off_fin = 2791.476 uV 13:57:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.778 uVs 13:57:30 Integrated Voltage Measurement... 13:57:39 Voltage Offset Correction: v_off_ini = 2779.336 uV, v_off_fin = 2762.671 uV 13:57:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -72.808 uVs 13:57:39 Integrated Voltage Measurement... 13:57:48 Voltage Offset Correction: v_off_ini = 2756.823 uV, v_off_fin = 2766.902 uV 13:57:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.277 uVs 13:57:50 I2X Average and RMS of Measurements VT = -62.815 +- 10.259 uVs I2X = 5.779 +- 0.944 uTm^2 13:57:53 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:57:55 Integrated Voltage Measurement... 13:58:04 Voltage Offset Correction: v_off_ini = 2732.625 uV, v_off_fin = 2748.038 uV 13:58:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -253.800 uVs 13:58:04 Integrated Voltage Measurement... 13:58:13 Voltage Offset Correction: v_off_ini = 2735.384 uV, v_off_fin = 2757.089 uV 13:58:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.733 uVs 13:58:13 Integrated Voltage Measurement... 13:58:22 Voltage Offset Correction: v_off_ini = 2745.741 uV, v_off_fin = 2752.998 uV 13:58:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -244.501 uVs 13:58:22 Integrated Voltage Measurement... 13:58:31 Voltage Offset Correction: v_off_ini = 2743.689 uV, v_off_fin = 2734.709 uV 13:58:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.027 uVs 13:58:31 Integrated Voltage Measurement... 13:58:40 Voltage Offset Correction: v_off_ini = 2747.085 uV, v_off_fin = 2750.955 uV 13:58:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.577 uVs 13:58:40 Integrated Voltage Measurement... 13:58:49 Voltage Offset Correction: v_off_ini = 2730.124 uV, v_off_fin = 2736.783 uV 13:58:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.640 uVs 13:58:52 I2Y Average and RMS of Measurements VT = -242.880 +- 5.937 uVs I2Y = -22.345 +- 0.546 uTm^2 13:58:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:59:00 Integrated Voltage Measurement... 13:59:09 Voltage Offset Correction: v_off_ini = 2750.710 uV, v_off_fin = 2735.102 uV 13:59:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -144.974 uVs 13:59:09 Integrated Voltage Measurement... 13:59:18 Voltage Offset Correction: v_off_ini = 2742.937 uV, v_off_fin = 2765.914 uV 13:59:18 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.578 uVs 13:59:18 Integrated Voltage Measurement... 13:59:27 Voltage Offset Correction: v_off_ini = 2750.757 uV, v_off_fin = 2730.746 uV 13:59:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -110.082 uVs 13:59:27 Integrated Voltage Measurement... 13:59:36 Voltage Offset Correction: v_off_ini = 2748.444 uV, v_off_fin = 2746.827 uV 13:59:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.465 uVs 13:59:36 Integrated Voltage Measurement... 13:59:45 Voltage Offset Correction: v_off_ini = 2750.418 uV, v_off_fin = 2743.641 uV 13:59:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.086 uVs 13:59:45 Integrated Voltage Measurement... 13:59:54 Voltage Offset Correction: v_off_ini = 2749.970 uV, v_off_fin = 2731.956 uV 13:59:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.312 uVs 13:59:58 I1X Average and RMS of Measurements VT = -120.750 +- 2.864 uVs I1X = 24.151 +- 0.573 uTm 14:00:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:00:05 Integrated Voltage Measurement... 14:00:14 Voltage Offset Correction: v_off_ini = 2725.666 uV, v_off_fin = 2725.788 uV 14:00:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.173 uVs 14:00:14 Integrated Voltage Measurement... 14:00:23 Voltage Offset Correction: v_off_ini = 2738.847 uV, v_off_fin = 2747.950 uV 14:00:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.154 uVs 14:00:23 Integrated Voltage Measurement... 14:00:32 Voltage Offset Correction: v_off_ini = 2748.700 uV, v_off_fin = 2721.890 uV 14:00:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.723 uVs 14:00:32 Integrated Voltage Measurement... 14:00:41 Voltage Offset Correction: v_off_ini = 2714.586 uV, v_off_fin = 2736.821 uV 14:00:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.047 uVs 14:00:41 Integrated Voltage Measurement... 14:00:50 Voltage Offset Correction: v_off_ini = 2713.616 uV, v_off_fin = 2696.229 uV 14:00:50 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.648 uVs 14:00:50 Integrated Voltage Measurement... 14:00:59 Voltage Offset Correction: v_off_ini = 2733.369 uV, v_off_fin = 2717.912 uV 14:00:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 234.107 uVs 14:01:03 I1Y Average and RMS of Measurements VT = -239.642 +- 4.203 uVs I1Y = -47.929 +- 0.840 uTm 14:01:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:01:08 Integrated Voltage Measurement... 14:01:17 Voltage Offset Correction: v_off_ini = 2706.842 uV, v_off_fin = 2710.689 uV 14:01:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.069 uVs 14:01:17 Integrated Voltage Measurement... 14:01:26 Voltage Offset Correction: v_off_ini = 2679.143 uV, v_off_fin = 2723.259 uV 14:01:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.401 uVs 14:01:26 Integrated Voltage Measurement... 14:01:35 Voltage Offset Correction: v_off_ini = 2710.088 uV, v_off_fin = 2712.483 uV 14:01:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -82.899 uVs 14:01:35 Integrated Voltage Measurement... 14:01:44 Voltage Offset Correction: v_off_ini = 2728.427 uV, v_off_fin = 2704.770 uV 14:01:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.626 uVs 14:01:44 Integrated Voltage Measurement... 14:01:53 Voltage Offset Correction: v_off_ini = 2716.182 uV, v_off_fin = 2724.571 uV 14:01:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.712 uVs 14:01:53 Integrated Voltage Measurement... 14:02:02 Voltage Offset Correction: v_off_ini = 2734.063 uV, v_off_fin = 2731.276 uV 14:02:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.777 uVs 14:02:05 I2X Average and RMS of Measurements VT = -75.247 +- 9.911 uVs I2X = 6.923 +- 0.912 uTm^2 14:02:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:02:10 Integrated Voltage Measurement... 14:02:19 Voltage Offset Correction: v_off_ini = 2734.918 uV, v_off_fin = 2711.544 uV 14:02:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.161 uVs 14:02:19 Integrated Voltage Measurement... 14:02:28 Voltage Offset Correction: v_off_ini = 2730.084 uV, v_off_fin = 2730.239 uV 14:02:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.976 uVs 14:02:28 Integrated Voltage Measurement... 14:02:37 Voltage Offset Correction: v_off_ini = 2727.176 uV, v_off_fin = 2731.127 uV 14:02:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -263.261 uVs 14:02:37 Integrated Voltage Measurement... 14:02:46 Voltage Offset Correction: v_off_ini = 2718.093 uV, v_off_fin = 2733.428 uV 14:02:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.712 uVs 14:02:46 Integrated Voltage Measurement... 14:02:55 Voltage Offset Correction: v_off_ini = 2732.876 uV, v_off_fin = 2720.636 uV 14:02:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.331 uVs 14:02:55 Integrated Voltage Measurement... 14:03:04 Voltage Offset Correction: v_off_ini = 2721.719 uV, v_off_fin = 2721.687 uV 14:03:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.665 uVs 14:03:06 I2Y Average and RMS of Measurements VT = -244.851 +- 12.601 uVs I2Y = -22.526 +- 1.159 uTm^2 14:03:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:03:15 Integrated Voltage Measurement... 14:03:24 Voltage Offset Correction: v_off_ini = 2710.947 uV, v_off_fin = 2712.366 uV 14:03:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -97.983 uVs 14:03:24 Integrated Voltage Measurement... 14:03:33 Voltage Offset Correction: v_off_ini = 2717.391 uV, v_off_fin = 2715.077 uV 14:03:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.766 uVs 14:03:33 Integrated Voltage Measurement... 14:03:42 Voltage Offset Correction: v_off_ini = 2747.924 uV, v_off_fin = 2732.623 uV 14:03:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -113.073 uVs 14:03:42 Integrated Voltage Measurement... 14:03:51 Voltage Offset Correction: v_off_ini = 2734.366 uV, v_off_fin = 2746.244 uV 14:03:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 99.359 uVs 14:03:51 Integrated Voltage Measurement... 14:04:00 Voltage Offset Correction: v_off_ini = 2742.575 uV, v_off_fin = 2737.942 uV 14:04:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.998 uVs 14:04:00 Integrated Voltage Measurement... 14:04:09 Voltage Offset Correction: v_off_ini = 2734.597 uV, v_off_fin = 2776.793 uV 14:04:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.632 uVs 14:04:13 I1X Average and RMS of Measurements VT = -101.635 +- 8.807 uVs I1X = 20.329 +- 1.762 uTm 14:04:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:04:20 Integrated Voltage Measurement... 14:04:29 Voltage Offset Correction: v_off_ini = 2765.268 uV, v_off_fin = 2759.579 uV 14:04:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.434 uVs 14:04:29 Integrated Voltage Measurement... 14:04:38 Voltage Offset Correction: v_off_ini = 2756.069 uV, v_off_fin = 2743.859 uV 14:04:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 239.943 uVs 14:04:38 Integrated Voltage Measurement... 14:04:47 Voltage Offset Correction: v_off_ini = 2746.098 uV, v_off_fin = 2732.286 uV 14:04:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.255 uVs 14:04:47 Integrated Voltage Measurement... 14:04:56 Voltage Offset Correction: v_off_ini = 2722.546 uV, v_off_fin = 2722.811 uV 14:04:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 253.581 uVs 14:04:56 Integrated Voltage Measurement... 14:05:05 Voltage Offset Correction: v_off_ini = 2709.594 uV, v_off_fin = 2705.894 uV 14:05:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -257.125 uVs 14:05:05 Integrated Voltage Measurement... 14:05:14 Voltage Offset Correction: v_off_ini = 2720.511 uV, v_off_fin = 2755.350 uV 14:05:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.370 uVs 14:05:18 I1Y Average and RMS of Measurements VT = -246.285 +- 4.176 uVs I1Y = -49.254 +- 0.835 uTm 14:05:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:05:23 Integrated Voltage Measurement... 14:05:32 Voltage Offset Correction: v_off_ini = 2725.674 uV, v_off_fin = 2703.748 uV 14:05:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.234 uVs 14:05:32 Integrated Voltage Measurement... 14:05:41 Voltage Offset Correction: v_off_ini = 2696.733 uV, v_off_fin = 2721.460 uV 14:05:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.847 uVs 14:05:41 Integrated Voltage Measurement... 14:05:50 Voltage Offset Correction: v_off_ini = 2717.626 uV, v_off_fin = 2718.008 uV 14:05:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.309 uVs 14:05:50 Integrated Voltage Measurement... 14:05:59 Voltage Offset Correction: v_off_ini = 2736.889 uV, v_off_fin = 2741.047 uV 14:05:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.020 uVs 14:05:59 Integrated Voltage Measurement... 14:06:08 Voltage Offset Correction: v_off_ini = 2750.232 uV, v_off_fin = 2730.270 uV 14:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.708 uVs 14:06:08 Integrated Voltage Measurement... 14:06:17 Voltage Offset Correction: v_off_ini = 2746.627 uV, v_off_fin = 2758.460 uV 14:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.090 uVs 14:06:19 I2X Average and RMS of Measurements VT = -58.368 +- 6.566 uVs I2X = 5.370 +- 0.604 uTm^2 14:06:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:06:25 Integrated Voltage Measurement... 14:06:33 Voltage Offset Correction: v_off_ini = 2724.376 uV, v_off_fin = 2731.617 uV 14:06:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.981 uVs 14:06:34 Integrated Voltage Measurement... 14:06:42 Voltage Offset Correction: v_off_ini = 2722.840 uV, v_off_fin = 2763.986 uV 14:06:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.067 uVs 14:06:43 Integrated Voltage Measurement... 14:06:52 Voltage Offset Correction: v_off_ini = 2762.188 uV, v_off_fin = 2777.419 uV 14:06:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.263 uVs 14:06:52 Integrated Voltage Measurement... 14:07:01 Voltage Offset Correction: v_off_ini = 2739.602 uV, v_off_fin = 2765.418 uV 14:07:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.457 uVs 14:07:01 Integrated Voltage Measurement... 14:07:10 Voltage Offset Correction: v_off_ini = 2752.191 uV, v_off_fin = 2764.518 uV 14:07:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.907 uVs 14:07:10 Integrated Voltage Measurement... 14:07:19 Voltage Offset Correction: v_off_ini = 2777.673 uV, v_off_fin = 2760.716 uV 14:07:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.143 uVs 14:07:21 I2Y Average and RMS of Measurements VT = -253.136 +- 5.236 uVs I2Y = -23.289 +- 0.482 uTm^2 14:07:25 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:07:29 Integrated Voltage Measurement... 14:07:38 Voltage Offset Correction: v_off_ini = 2741.963 uV, v_off_fin = 2745.022 uV 14:07:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -128.957 uVs 14:07:38 Integrated Voltage Measurement... 14:07:47 Voltage Offset Correction: v_off_ini = 2741.182 uV, v_off_fin = 2754.083 uV 14:07:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.782 uVs 14:07:47 Integrated Voltage Measurement... 14:07:56 Voltage Offset Correction: v_off_ini = 2720.842 uV, v_off_fin = 2747.006 uV 14:07:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.861 uVs 14:07:56 Integrated Voltage Measurement... 14:08:05 Voltage Offset Correction: v_off_ini = 2762.788 uV, v_off_fin = 2751.577 uV 14:08:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.665 uVs 14:08:05 Integrated Voltage Measurement... 14:08:14 Voltage Offset Correction: v_off_ini = 2741.122 uV, v_off_fin = 2739.503 uV 14:08:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -112.642 uVs 14:08:14 Integrated Voltage Measurement... 14:08:23 Voltage Offset Correction: v_off_ini = 2751.931 uV, v_off_fin = 2749.048 uV 14:08:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.039 uVs 14:08:28 I1X Average and RMS of Measurements VT = -96.824 +- 6.575 uVs I1X = 19.367 +- 1.317 uTm 14:08:30 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:08:34 Integrated Voltage Measurement... 14:08:43 Voltage Offset Correction: v_off_ini = 2729.399 uV, v_off_fin = 2712.308 uV 14:08:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -241.759 uVs 14:08:43 Integrated Voltage Measurement... 14:08:52 Voltage Offset Correction: v_off_ini = 2752.900 uV, v_off_fin = 2747.554 uV 14:08:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 223.986 uVs 14:08:52 Integrated Voltage Measurement... 14:09:01 Voltage Offset Correction: v_off_ini = 2738.794 uV, v_off_fin = 2726.622 uV 14:09:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -237.678 uVs 14:09:01 Integrated Voltage Measurement... 14:09:10 Voltage Offset Correction: v_off_ini = 2715.294 uV, v_off_fin = 2745.940 uV 14:09:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 250.751 uVs 14:09:10 Integrated Voltage Measurement... 14:09:19 Voltage Offset Correction: v_off_ini = 2754.973 uV, v_off_fin = 2742.857 uV 14:09:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -249.586 uVs 14:09:19 Integrated Voltage Measurement... 14:09:28 Voltage Offset Correction: v_off_ini = 2746.131 uV, v_off_fin = 2765.969 uV 14:09:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 257.092 uVs 14:09:32 I1Y Average and RMS of Measurements VT = -243.475 +- 8.372 uVs I1Y = -48.690 +- 1.674 uTm 14:09:35 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:09:38 Integrated Voltage Measurement... 14:09:47 Voltage Offset Correction: v_off_ini = 2732.488 uV, v_off_fin = 2731.510 uV 14:09:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.903 uVs 14:09:47 Integrated Voltage Measurement... 14:09:56 Voltage Offset Correction: v_off_ini = 2737.687 uV, v_off_fin = 2733.547 uV 14:09:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.310 uVs 14:09:56 Integrated Voltage Measurement... 14:10:05 Voltage Offset Correction: v_off_ini = 2745.972 uV, v_off_fin = 2698.470 uV 14:10:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.546 uVs 14:10:05 Integrated Voltage Measurement... 14:10:14 Voltage Offset Correction: v_off_ini = 2731.941 uV, v_off_fin = 2751.047 uV 14:10:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.617 uVs 14:10:14 Integrated Voltage Measurement... 14:10:23 Voltage Offset Correction: v_off_ini = 2748.606 uV, v_off_fin = 2749.890 uV 14:10:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.965 uVs 14:10:23 Integrated Voltage Measurement... 14:10:32 Voltage Offset Correction: v_off_ini = 2731.105 uV, v_off_fin = 2735.238 uV 14:10:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.934 uVs 14:10:34 I2X Average and RMS of Measurements VT = -55.379 +- 3.240 uVs I2X = 5.095 +- 0.298 uTm^2 14:10:37 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:10:39 Integrated Voltage Measurement... 14:10:48 Voltage Offset Correction: v_off_ini = 2734.438 uV, v_off_fin = 2723.041 uV 14:10:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.869 uVs 14:10:48 Integrated Voltage Measurement... 14:10:57 Voltage Offset Correction: v_off_ini = 2710.806 uV, v_off_fin = 2720.131 uV 14:10:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.852 uVs 14:10:57 Integrated Voltage Measurement... 14:11:06 Voltage Offset Correction: v_off_ini = 2720.669 uV, v_off_fin = 2727.642 uV 14:11:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.811 uVs 14:11:06 Integrated Voltage Measurement... 14:11:15 Voltage Offset Correction: v_off_ini = 2707.314 uV, v_off_fin = 2705.205 uV 14:11:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.492 uVs 14:11:15 Integrated Voltage Measurement... 14:11:24 Voltage Offset Correction: v_off_ini = 2711.727 uV, v_off_fin = 2711.021 uV 14:11:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.484 uVs 14:11:24 Integrated Voltage Measurement... 14:11:33 Voltage Offset Correction: v_off_ini = 2690.741 uV, v_off_fin = 2711.053 uV 14:11:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.145 uVs 14:11:36 I2Y Average and RMS of Measurements VT = -245.109 +- 13.508 uVs I2Y = -22.550 +- 1.243 uTm^2 14:11:53 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:11:57 Integrated Voltage Measurement... 14:12:06 Voltage Offset Correction: v_off_ini = 2651.853 uV, v_off_fin = 2678.424 uV 14:12:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -100.092 uVs 14:12:06 Integrated Voltage Measurement... 14:12:15 Voltage Offset Correction: v_off_ini = 2692.572 uV, v_off_fin = 2686.888 uV 14:12:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 98.684 uVs 14:12:15 Integrated Voltage Measurement... 14:12:24 Voltage Offset Correction: v_off_ini = 2675.741 uV, v_off_fin = 2667.582 uV 14:12:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.555 uVs 14:12:24 Integrated Voltage Measurement... 14:12:33 Voltage Offset Correction: v_off_ini = 2677.311 uV, v_off_fin = 2655.031 uV 14:12:33 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 136.493 uVs 14:12:33 Integrated Voltage Measurement... 14:12:42 Voltage Offset Correction: v_off_ini = 2670.068 uV, v_off_fin = 2673.815 uV 14:12:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.091 uVs 14:12:42 Integrated Voltage Measurement... 14:12:51 Voltage Offset Correction: v_off_ini = 2665.982 uV, v_off_fin = 2669.249 uV 14:12:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.931 uVs 14:12:55 I1X Average and RMS of Measurements VT = -117.641 +- 17.110 uVs I1X = 23.530 +- 3.422 uTm 14:12:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:13:02 Integrated Voltage Measurement... 14:13:11 Voltage Offset Correction: v_off_ini = 2669.387 uV, v_off_fin = 2646.916 uV 14:13:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.481 uVs 14:13:11 Integrated Voltage Measurement... 14:13:20 Voltage Offset Correction: v_off_ini = 2677.442 uV, v_off_fin = 2673.801 uV 14:13:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.552 uVs 14:13:20 Integrated Voltage Measurement... 14:13:29 Voltage Offset Correction: v_off_ini = 2667.585 uV, v_off_fin = 2671.767 uV 14:13:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.741 uVs 14:13:29 Integrated Voltage Measurement... 14:13:38 Voltage Offset Correction: v_off_ini = 2682.083 uV, v_off_fin = 2704.523 uV 14:13:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.248 uVs 14:13:38 Integrated Voltage Measurement... 14:13:47 Voltage Offset Correction: v_off_ini = 2696.031 uV, v_off_fin = 2683.356 uV 14:13:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.892 uVs 14:13:47 Integrated Voltage Measurement... 14:13:56 Voltage Offset Correction: v_off_ini = 2693.649 uV, v_off_fin = 2726.768 uV 14:13:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.997 uVs 14:14:00 I1Y Average and RMS of Measurements VT = -218.652 +- 6.874 uVs I1Y = -43.730 +- 1.375 uTm 14:14:05 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:14:08 Integrated Voltage Measurement... 14:14:17 Voltage Offset Correction: v_off_ini = 2731.062 uV, v_off_fin = 2726.973 uV 14:14:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -105.749 uVs 14:14:17 Integrated Voltage Measurement... 14:14:26 Voltage Offset Correction: v_off_ini = 2715.727 uV, v_off_fin = 2721.641 uV 14:14:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.678 uVs 14:14:26 Integrated Voltage Measurement... 14:14:35 Voltage Offset Correction: v_off_ini = 2722.495 uV, v_off_fin = 2696.234 uV 14:14:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.019 uVs 14:14:35 Integrated Voltage Measurement... 14:14:44 Voltage Offset Correction: v_off_ini = 2727.242 uV, v_off_fin = 2712.428 uV 14:14:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.948 uVs 14:14:44 Integrated Voltage Measurement... 14:14:53 Voltage Offset Correction: v_off_ini = 2710.693 uV, v_off_fin = 2705.751 uV 14:14:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.795 uVs 14:14:53 Integrated Voltage Measurement... 14:15:02 Voltage Offset Correction: v_off_ini = 2724.128 uV, v_off_fin = 2731.479 uV 14:15:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.593 uVs 14:15:04 I2X Average and RMS of Measurements VT = -94.797 +- 4.538 uVs I2X = 8.721 +- 0.418 uTm^2 14:15:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:15:12 Integrated Voltage Measurement... 14:15:21 Voltage Offset Correction: v_off_ini = 2717.159 uV, v_off_fin = 2702.886 uV 14:15:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.854 uVs 14:15:21 Integrated Voltage Measurement... 14:15:30 Voltage Offset Correction: v_off_ini = 2675.151 uV, v_off_fin = 2697.526 uV 14:15:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.892 uVs 14:15:30 Integrated Voltage Measurement... 14:15:39 Voltage Offset Correction: v_off_ini = 2709.843 uV, v_off_fin = 2717.902 uV 14:15:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.732 uVs 14:15:39 Integrated Voltage Measurement... 14:15:48 Voltage Offset Correction: v_off_ini = 2685.009 uV, v_off_fin = 2695.354 uV 14:15:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.904 uVs 14:15:48 Integrated Voltage Measurement... 14:15:57 Voltage Offset Correction: v_off_ini = 2695.399 uV, v_off_fin = 2660.893 uV 14:15:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.718 uVs 14:15:57 Integrated Voltage Measurement... 14:16:06 Voltage Offset Correction: v_off_ini = 2655.106 uV, v_off_fin = 2656.302 uV 14:16:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.808 uVs 14:16:08 I2Y Average and RMS of Measurements VT = -208.651 +- 3.732 uVs I2Y = -19.196 +- 0.343 uTm^2 14:16:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:16:17 Integrated Voltage Measurement... 14:16:26 Voltage Offset Correction: v_off_ini = 2695.251 uV, v_off_fin = 2698.515 uV 14:16:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -151.146 uVs 14:16:26 Integrated Voltage Measurement... 14:16:35 Voltage Offset Correction: v_off_ini = 2703.210 uV, v_off_fin = 2689.472 uV 14:16:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 119.974 uVs 14:16:35 Integrated Voltage Measurement... 14:16:44 Voltage Offset Correction: v_off_ini = 2675.246 uV, v_off_fin = 2667.701 uV 14:16:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -105.240 uVs 14:16:44 Integrated Voltage Measurement... 14:16:53 Voltage Offset Correction: v_off_ini = 2669.520 uV, v_off_fin = 2655.080 uV 14:16:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.718 uVs 14:16:53 Integrated Voltage Measurement... 14:17:02 Voltage Offset Correction: v_off_ini = 2659.424 uV, v_off_fin = 2648.970 uV 14:17:02 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -82.315 uVs 14:17:02 Integrated Voltage Measurement... 14:17:11 Voltage Offset Correction: v_off_ini = 2669.901 uV, v_off_fin = 2670.277 uV 14:17:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 108.792 uVs 14:17:16 I1X Average and RMS of Measurements VT = -115.697 +- 16.334 uVs I1X = 23.142 +- 3.267 uTm 14:17:18 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:17:22 Integrated Voltage Measurement... 14:17:31 Voltage Offset Correction: v_off_ini = 2637.500 uV, v_off_fin = 2643.203 uV 14:17:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.901 uVs 14:17:31 Integrated Voltage Measurement... 14:17:40 Voltage Offset Correction: v_off_ini = 2664.458 uV, v_off_fin = 2676.054 uV 14:17:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.932 uVs 14:17:40 Integrated Voltage Measurement... 14:17:49 Voltage Offset Correction: v_off_ini = 2653.258 uV, v_off_fin = 2646.817 uV 14:17:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.002 uVs 14:17:49 Integrated Voltage Measurement... 14:17:58 Voltage Offset Correction: v_off_ini = 2678.365 uV, v_off_fin = 2672.427 uV 14:17:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.312 uVs 14:17:58 Integrated Voltage Measurement... 14:18:07 Voltage Offset Correction: v_off_ini = 2680.017 uV, v_off_fin = 2667.962 uV 14:18:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.573 uVs 14:18:07 Integrated Voltage Measurement... 14:18:16 Voltage Offset Correction: v_off_ini = 2660.483 uV, v_off_fin = 2668.600 uV 14:18:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.198 uVs 14:18:20 I1Y Average and RMS of Measurements VT = -231.653 +- 2.487 uVs I1Y = -46.331 +- 0.497 uTm 14:18:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:18:28 Integrated Voltage Measurement... 14:18:37 Voltage Offset Correction: v_off_ini = 2681.321 uV, v_off_fin = 2672.700 uV 14:18:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.913 uVs 14:18:37 Integrated Voltage Measurement... 14:18:46 Voltage Offset Correction: v_off_ini = 2690.107 uV, v_off_fin = 2682.908 uV 14:18:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.398 uVs 14:18:46 Integrated Voltage Measurement... 14:18:55 Voltage Offset Correction: v_off_ini = 2678.214 uV, v_off_fin = 2677.468 uV 14:18:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.426 uVs 14:18:55 Integrated Voltage Measurement... 14:19:04 Voltage Offset Correction: v_off_ini = 2690.960 uV, v_off_fin = 2690.853 uV 14:19:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.605 uVs 14:19:04 Integrated Voltage Measurement... 14:19:13 Voltage Offset Correction: v_off_ini = 2677.185 uV, v_off_fin = 2660.304 uV 14:19:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.033 uVs 14:19:13 Integrated Voltage Measurement... 14:19:22 Voltage Offset Correction: v_off_ini = 2692.243 uV, v_off_fin = 2684.134 uV 14:19:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.585 uVs 14:19:25 I2X Average and RMS of Measurements VT = -85.827 +- 0.843 uVs I2X = 7.896 +- 0.078 uTm^2 14:19:30 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:19:32 Integrated Voltage Measurement... 14:19:41 Voltage Offset Correction: v_off_ini = 2665.733 uV, v_off_fin = 2654.425 uV 14:19:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.507 uVs 14:19:41 Integrated Voltage Measurement... 14:19:50 Voltage Offset Correction: v_off_ini = 2645.879 uV, v_off_fin = 2645.751 uV 14:19:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.204 uVs 14:19:50 Integrated Voltage Measurement... 14:19:59 Voltage Offset Correction: v_off_ini = 2665.185 uV, v_off_fin = 2668.142 uV 14:19:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.809 uVs 14:19:59 Integrated Voltage Measurement... 14:20:08 Voltage Offset Correction: v_off_ini = 2673.811 uV, v_off_fin = 2691.050 uV 14:20:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.104 uVs 14:20:08 Integrated Voltage Measurement... 14:20:17 Voltage Offset Correction: v_off_ini = 2681.308 uV, v_off_fin = 2673.627 uV 14:20:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -229.651 uVs 14:20:17 Integrated Voltage Measurement... 14:20:26 Voltage Offset Correction: v_off_ini = 2656.025 uV, v_off_fin = 2649.651 uV 14:20:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.352 uVs 14:20:29 I2Y Average and RMS of Measurements VT = -213.271 +- 4.646 uVs I2Y = -19.621 +- 0.427 uTm^2 14:20:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:38 Integrated Voltage Measurement... 14:20:47 Voltage Offset Correction: v_off_ini = 2681.296 uV, v_off_fin = 2690.888 uV 14:20:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -129.520 uVs 14:20:47 Integrated Voltage Measurement... 14:20:56 Voltage Offset Correction: v_off_ini = 2659.055 uV, v_off_fin = 2669.648 uV 14:20:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 158.492 uVs 14:20:56 Integrated Voltage Measurement... 14:21:05 Voltage Offset Correction: v_off_ini = 2668.236 uV, v_off_fin = 2670.627 uV 14:21:05 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -134.321 uVs 14:21:05 Integrated Voltage Measurement... 14:21:14 Voltage Offset Correction: v_off_ini = 2678.849 uV, v_off_fin = 2680.717 uV 14:21:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 143.556 uVs 14:21:14 Integrated Voltage Measurement... 14:21:23 Voltage Offset Correction: v_off_ini = 2710.241 uV, v_off_fin = 2700.347 uV 14:21:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.996 uVs 14:21:23 Integrated Voltage Measurement... 14:21:32 Voltage Offset Correction: v_off_ini = 2733.892 uV, v_off_fin = 2701.359 uV 14:21:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.064 uVs 14:21:36 I1X Average and RMS of Measurements VT = -128.492 +- 18.474 uVs I1X = 25.702 +- 3.696 uTm 14:21:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:21:43 Integrated Voltage Measurement... 14:21:52 Voltage Offset Correction: v_off_ini = 2689.060 uV, v_off_fin = 2692.412 uV 14:21:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.113 uVs 14:21:52 Integrated Voltage Measurement... 14:22:01 Voltage Offset Correction: v_off_ini = 2705.294 uV, v_off_fin = 2713.066 uV 14:22:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.760 uVs 14:22:01 Integrated Voltage Measurement... 14:22:10 Voltage Offset Correction: v_off_ini = 2727.424 uV, v_off_fin = 2707.209 uV 14:22:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -234.014 uVs 14:22:10 Integrated Voltage Measurement... 14:22:19 Voltage Offset Correction: v_off_ini = 2715.587 uV, v_off_fin = 2724.863 uV 14:22:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.294 uVs 14:22:19 Integrated Voltage Measurement... 14:22:28 Voltage Offset Correction: v_off_ini = 2725.098 uV, v_off_fin = 2721.166 uV 14:22:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.964 uVs 14:22:28 Integrated Voltage Measurement... 14:22:36 Voltage Offset Correction: v_off_ini = 2718.244 uV, v_off_fin = 2729.938 uV 14:22:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.487 uVs 14:22:41 I1Y Average and RMS of Measurements VT = -219.939 +- 7.581 uVs I1Y = -43.988 +- 1.516 uTm 14:22:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:22:48 Integrated Voltage Measurement... 14:22:57 Voltage Offset Correction: v_off_ini = 2728.806 uV, v_off_fin = 2712.715 uV 14:22:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.463 uVs 14:22:57 Integrated Voltage Measurement... 14:23:06 Voltage Offset Correction: v_off_ini = 2734.334 uV, v_off_fin = 2721.457 uV 14:23:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.015 uVs 14:23:06 Integrated Voltage Measurement... 14:23:15 Voltage Offset Correction: v_off_ini = 2752.739 uV, v_off_fin = 2729.957 uV 14:23:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.562 uVs 14:23:15 Integrated Voltage Measurement... 14:23:24 Voltage Offset Correction: v_off_ini = 2735.386 uV, v_off_fin = 2737.894 uV 14:23:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.637 uVs 14:23:24 Integrated Voltage Measurement... 14:23:33 Voltage Offset Correction: v_off_ini = 2713.191 uV, v_off_fin = 2721.478 uV 14:23:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -84.125 uVs 14:23:33 Integrated Voltage Measurement... 14:23:42 Voltage Offset Correction: v_off_ini = 2728.387 uV, v_off_fin = 2736.720 uV 14:23:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.532 uVs 14:23:45 I2X Average and RMS of Measurements VT = -90.222 +- 8.738 uVs I2X = 8.300 +- 0.804 uTm^2 14:23:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:23:52 Integrated Voltage Measurement... 14:24:01 Voltage Offset Correction: v_off_ini = 2702.408 uV, v_off_fin = 2727.200 uV 14:24:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.528 uVs 14:24:01 Integrated Voltage Measurement... 14:24:10 Voltage Offset Correction: v_off_ini = 2722.292 uV, v_off_fin = 2738.270 uV 14:24:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.455 uVs 14:24:10 Integrated Voltage Measurement... 14:24:19 Voltage Offset Correction: v_off_ini = 2756.644 uV, v_off_fin = 2719.957 uV 14:24:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.117 uVs 14:24:19 Integrated Voltage Measurement... 14:24:28 Voltage Offset Correction: v_off_ini = 2748.885 uV, v_off_fin = 2759.443 uV 14:24:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 241.262 uVs 14:24:29 Integrated Voltage Measurement... 14:24:37 Voltage Offset Correction: v_off_ini = 2754.740 uV, v_off_fin = 2753.964 uV 14:24:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.970 uVs 14:24:38 Integrated Voltage Measurement... 14:24:47 Voltage Offset Correction: v_off_ini = 2754.243 uV, v_off_fin = 2761.688 uV 14:24:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.682 uVs 14:24:49 I2Y Average and RMS of Measurements VT = -218.836 +- 8.858 uVs I2Y = -20.133 +- 0.815 uTm^2 14:24:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:24:58 Integrated Voltage Measurement... 14:25:07 Voltage Offset Correction: v_off_ini = 2785.306 uV, v_off_fin = 2772.082 uV 14:25:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -142.600 uVs 14:25:07 Integrated Voltage Measurement... 14:25:16 Voltage Offset Correction: v_off_ini = 2741.599 uV, v_off_fin = 2789.974 uV 14:25:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.318 uVs 14:25:16 Integrated Voltage Measurement... 14:25:25 Voltage Offset Correction: v_off_ini = 2773.989 uV, v_off_fin = 2754.322 uV 14:25:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -154.085 uVs 14:25:25 Integrated Voltage Measurement... 14:25:34 Voltage Offset Correction: v_off_ini = 2749.920 uV, v_off_fin = 2759.194 uV 14:25:34 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 120.392 uVs 14:25:34 Integrated Voltage Measurement... 14:25:43 Voltage Offset Correction: v_off_ini = 2767.361 uV, v_off_fin = 2758.068 uV 14:25:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -116.813 uVs 14:25:43 Integrated Voltage Measurement... 14:25:52 Voltage Offset Correction: v_off_ini = 2780.872 uV, v_off_fin = 2773.085 uV 14:25:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.370 uVs 14:25:56 I1X Average and RMS of Measurements VT = -126.096 +- 12.851 uVs I1X = 25.222 +- 2.571 uTm 14:25:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:26:03 Integrated Voltage Measurement... 14:26:12 Voltage Offset Correction: v_off_ini = 2773.328 uV, v_off_fin = 2777.417 uV 14:26:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = -234.588 uVs 14:26:12 Integrated Voltage Measurement... 14:26:21 Voltage Offset Correction: v_off_ini = 2787.232 uV, v_off_fin = 2788.308 uV 14:26:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.403 uVs 14:26:21 Integrated Voltage Measurement... 14:26:30 Voltage Offset Correction: v_off_ini = 2777.617 uV, v_off_fin = 2780.366 uV 14:26:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.318 uVs 14:26:30 Integrated Voltage Measurement... 14:26:39 Voltage Offset Correction: v_off_ini = 2790.957 uV, v_off_fin = 2814.398 uV 14:26:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.739 uVs 14:26:39 Integrated Voltage Measurement... 14:26:47 Voltage Offset Correction: v_off_ini = 2805.163 uV, v_off_fin = 2792.698 uV 14:26:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -260.079 uVs 14:26:48 Integrated Voltage Measurement... 14:26:56 Voltage Offset Correction: v_off_ini = 2777.045 uV, v_off_fin = 2823.614 uV 14:26:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 214.094 uVs 14:27:01 I1Y Average and RMS of Measurements VT = -239.370 +- 1.615 uVs I1Y = -47.876 +- 0.325 uTm 14:27:06 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:27:08 Integrated Voltage Measurement... 14:27:17 Voltage Offset Correction: v_off_ini = 2813.543 uV, v_off_fin = 2807.067 uV 14:27:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -85.823 uVs 14:27:17 Integrated Voltage Measurement... 14:27:26 Voltage Offset Correction: v_off_ini = 2797.266 uV, v_off_fin = 2801.987 uV 14:27:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.120 uVs 14:27:26 Integrated Voltage Measurement... 14:27:35 Voltage Offset Correction: v_off_ini = 2808.843 uV, v_off_fin = 2779.816 uV 14:27:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.391 uVs 14:27:35 Integrated Voltage Measurement... 14:27:44 Voltage Offset Correction: v_off_ini = 2795.425 uV, v_off_fin = 2806.804 uV 14:27:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.522 uVs 14:27:44 Integrated Voltage Measurement... 14:27:53 Voltage Offset Correction: v_off_ini = 2805.337 uV, v_off_fin = 2801.875 uV 14:27:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.737 uVs 14:27:53 Integrated Voltage Measurement... 14:28:02 Voltage Offset Correction: v_off_ini = 2785.772 uV, v_off_fin = 2779.572 uV 14:28:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.043 uVs 14:28:05 I2X Average and RMS of Measurements VT = -85.106 +- 5.765 uVs I2X = 7.830 +- 0.530 uTm^2 14:28:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:28:12 Integrated Voltage Measurement... 14:28:21 Voltage Offset Correction: v_off_ini = 2770.474 uV, v_off_fin = 2776.764 uV 14:28:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.817 uVs 14:28:21 Integrated Voltage Measurement... 14:28:30 Voltage Offset Correction: v_off_ini = 2796.454 uV, v_off_fin = 2798.009 uV 14:28:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.436 uVs 14:28:30 Integrated Voltage Measurement... 14:28:39 Voltage Offset Correction: v_off_ini = 2773.311 uV, v_off_fin = 2770.337 uV 14:28:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.869 uVs 14:28:39 Integrated Voltage Measurement... 14:28:48 Voltage Offset Correction: v_off_ini = 2802.931 uV, v_off_fin = 2795.427 uV 14:28:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.997 uVs 14:28:48 Integrated Voltage Measurement... 14:28:57 Voltage Offset Correction: v_off_ini = 2789.588 uV, v_off_fin = 2805.330 uV 14:28:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.828 uVs 14:28:58 Integrated Voltage Measurement... 14:29:06 Voltage Offset Correction: v_off_ini = 2787.568 uV, v_off_fin = 2819.475 uV 14:29:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.130 uVs 14:29:09 I2Y Average and RMS of Measurements VT = -237.013 +- 20.778 uVs I2Y = -21.805 +- 1.912 uTm^2 14:29:13 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:29:18 Integrated Voltage Measurement... 14:29:27 Voltage Offset Correction: v_off_ini = 2788.848 uV, v_off_fin = 2799.291 uV 14:29:27 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -138.220 uVs 14:29:27 Integrated Voltage Measurement... 14:29:36 Voltage Offset Correction: v_off_ini = 2797.012 uV, v_off_fin = 2799.770 uV 14:29:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.646 uVs 14:29:36 Integrated Voltage Measurement... 14:29:45 Voltage Offset Correction: v_off_ini = 2782.563 uV, v_off_fin = 2788.427 uV 14:29:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.514 uVs 14:29:45 Integrated Voltage Measurement... 14:29:54 Voltage Offset Correction: v_off_ini = 2814.628 uV, v_off_fin = 2810.570 uV 14:29:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.036 uVs 14:29:54 Integrated Voltage Measurement... 14:30:03 Voltage Offset Correction: v_off_ini = 2792.375 uV, v_off_fin = 2776.594 uV 14:30:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.460 uVs 14:30:03 Integrated Voltage Measurement... 14:30:12 Voltage Offset Correction: v_off_ini = 2804.768 uV, v_off_fin = 2799.987 uV 14:30:12 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.216 uVs 14:30:16 I1X Average and RMS of Measurements VT = -127.015 +- 1.678 uVs I1X = 25.404 +- 0.335 uTm 14:30:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:30:23 Integrated Voltage Measurement... 14:30:32 Voltage Offset Correction: v_off_ini = 2818.936 uV, v_off_fin = 2817.824 uV 14:30:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -252.542 uVs 14:30:32 Integrated Voltage Measurement... 14:30:40 Voltage Offset Correction: v_off_ini = 2817.416 uV, v_off_fin = 2812.664 uV 14:30:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.330 uVs 14:30:41 Integrated Voltage Measurement... 14:30:49 Voltage Offset Correction: v_off_ini = 2819.470 uV, v_off_fin = 2803.146 uV 14:30:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -244.172 uVs 14:30:50 Integrated Voltage Measurement... 14:30:58 Voltage Offset Correction: v_off_ini = 2837.418 uV, v_off_fin = 2836.585 uV 14:30:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.428 uVs 14:30:59 Integrated Voltage Measurement... 14:31:07 Voltage Offset Correction: v_off_ini = 2816.923 uV, v_off_fin = 2808.416 uV 14:31:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.417 uVs 14:31:08 Integrated Voltage Measurement... 14:31:16 Voltage Offset Correction: v_off_ini = 2823.487 uV, v_off_fin = 2840.089 uV 14:31:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.463 uVs 14:31:21 I1Y Average and RMS of Measurements VT = -234.892 +- 8.744 uVs I1Y = -46.980 +- 1.751 uTm 14:31:26 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:31:28 Integrated Voltage Measurement... 14:31:37 Voltage Offset Correction: v_off_ini = 2795.822 uV, v_off_fin = 2781.671 uV 14:31:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.150 uVs 14:31:37 Integrated Voltage Measurement... 14:31:46 Voltage Offset Correction: v_off_ini = 2819.749 uV, v_off_fin = 2822.815 uV 14:31:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.026 uVs 14:31:46 Integrated Voltage Measurement... 14:31:55 Voltage Offset Correction: v_off_ini = 2817.224 uV, v_off_fin = 2816.352 uV 14:31:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.219 uVs 14:31:55 Integrated Voltage Measurement... 14:32:04 Voltage Offset Correction: v_off_ini = 2842.595 uV, v_off_fin = 2826.676 uV 14:32:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.305 uVs 14:32:04 Integrated Voltage Measurement... 14:32:13 Voltage Offset Correction: v_off_ini = 2819.140 uV, v_off_fin = 2819.634 uV 14:32:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.915 uVs 14:32:13 Integrated Voltage Measurement... 14:32:22 Voltage Offset Correction: v_off_ini = 2836.066 uV, v_off_fin = 2819.266 uV 14:32:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.139 uVs 14:32:25 I2X Average and RMS of Measurements VT = -93.292 +- 4.435 uVs I2X = 8.583 +- 0.408 uTm^2 14:32:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:32:32 Integrated Voltage Measurement... 14:32:41 Voltage Offset Correction: v_off_ini = 2851.513 uV, v_off_fin = 2857.979 uV 14:32:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.866 uVs 14:32:41 Integrated Voltage Measurement... 14:32:50 Voltage Offset Correction: v_off_ini = 2826.852 uV, v_off_fin = 2833.152 uV 14:32:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.288 uVs 14:32:50 Integrated Voltage Measurement... 14:32:59 Voltage Offset Correction: v_off_ini = 2804.046 uV, v_off_fin = 2825.119 uV 14:32:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -241.884 uVs 14:32:59 Integrated Voltage Measurement... 14:33:08 Voltage Offset Correction: v_off_ini = 2822.419 uV, v_off_fin = 2837.053 uV 14:33:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.327 uVs 14:33:08 Integrated Voltage Measurement... 14:33:17 Voltage Offset Correction: v_off_ini = 2839.583 uV, v_off_fin = 2810.239 uV 14:33:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.466 uVs 14:33:18 Integrated Voltage Measurement... 14:33:26 Voltage Offset Correction: v_off_ini = 2793.877 uV, v_off_fin = 2827.863 uV 14:33:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 257.568 uVs 14:33:29 I2Y Average and RMS of Measurements VT = -243.066 +- 10.267 uVs I2Y = -22.362 +- 0.945 uTm^2 14:33:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:33:41 Integrated Voltage Measurement... 14:33:50 Voltage Offset Correction: v_off_ini = 2811.582 uV, v_off_fin = 2816.318 uV 14:33:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.350 uVs 14:33:50 Integrated Voltage Measurement... 14:33:59 Voltage Offset Correction: v_off_ini = 2834.236 uV, v_off_fin = 2812.367 uV 14:33:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.379 uVs 14:33:59 Integrated Voltage Measurement... 14:34:08 Voltage Offset Correction: v_off_ini = 2817.411 uV, v_off_fin = 2798.726 uV 14:34:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.282 uVs 14:34:08 Integrated Voltage Measurement... 14:34:17 Voltage Offset Correction: v_off_ini = 2800.250 uV, v_off_fin = 2801.717 uV 14:34:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.146 uVs 14:34:17 Integrated Voltage Measurement... 14:34:26 Voltage Offset Correction: v_off_ini = 2786.579 uV, v_off_fin = 2795.167 uV 14:34:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.548 uVs 14:34:26 Integrated Voltage Measurement... 14:34:35 Voltage Offset Correction: v_off_ini = 2787.444 uV, v_off_fin = 2785.662 uV 14:34:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.672 uVs 14:34:39 I1X Average and RMS of Measurements VT = -124.896 +- 7.865 uVs I1X = 24.980 +- 1.573 uTm 14:34:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:34:46 Integrated Voltage Measurement... 14:34:55 Voltage Offset Correction: v_off_ini = 2773.759 uV, v_off_fin = 2750.033 uV 14:34:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.995 uVs 14:34:55 Integrated Voltage Measurement... 14:35:04 Voltage Offset Correction: v_off_ini = 2775.535 uV, v_off_fin = 2799.788 uV 14:35:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 232.513 uVs 14:35:04 Integrated Voltage Measurement... 14:35:13 Voltage Offset Correction: v_off_ini = 2788.000 uV, v_off_fin = 2771.066 uV 14:35:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.252 uVs 14:35:13 Integrated Voltage Measurement... 14:35:22 Voltage Offset Correction: v_off_ini = 2787.186 uV, v_off_fin = 2799.069 uV 14:35:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.488 uVs 14:35:22 Integrated Voltage Measurement... 14:35:31 Voltage Offset Correction: v_off_ini = 2776.137 uV, v_off_fin = 2758.778 uV 14:35:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.496 uVs 14:35:31 Integrated Voltage Measurement... 14:35:40 Voltage Offset Correction: v_off_ini = 2773.325 uV, v_off_fin = 2791.596 uV 14:35:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.740 uVs 14:35:44 I1Y Average and RMS of Measurements VT = -222.747 +- 10.021 uVs I1Y = -44.549 +- 2.004 uTm 14:35:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:35:49 Integrated Voltage Measurement... 14:35:58 Voltage Offset Correction: v_off_ini = 2776.983 uV, v_off_fin = 2801.166 uV 14:35:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -112.432 uVs 14:35:58 Integrated Voltage Measurement... 14:36:07 Voltage Offset Correction: v_off_ini = 2812.776 uV, v_off_fin = 2820.008 uV 14:36:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.118 uVs 14:36:07 Integrated Voltage Measurement... 14:36:16 Voltage Offset Correction: v_off_ini = 2792.891 uV, v_off_fin = 2791.249 uV 14:36:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.910 uVs 14:36:16 Integrated Voltage Measurement... 14:36:25 Voltage Offset Correction: v_off_ini = 2801.021 uV, v_off_fin = 2807.506 uV 14:36:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.798 uVs 14:36:25 Integrated Voltage Measurement... 14:36:34 Voltage Offset Correction: v_off_ini = 2798.862 uV, v_off_fin = 2790.148 uV 14:36:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.330 uVs 14:36:34 Integrated Voltage Measurement... 14:36:43 Voltage Offset Correction: v_off_ini = 2774.526 uV, v_off_fin = 2777.613 uV 14:36:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.227 uVs 14:36:46 I2X Average and RMS of Measurements VT = -94.636 +- 5.213 uVs I2X = 8.707 +- 0.480 uTm^2 14:36:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:36:51 Integrated Voltage Measurement... 14:37:00 Voltage Offset Correction: v_off_ini = 2796.953 uV, v_off_fin = 2812.423 uV 14:37:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.863 uVs 14:37:00 Integrated Voltage Measurement... 14:37:09 Voltage Offset Correction: v_off_ini = 2804.799 uV, v_off_fin = 2806.286 uV 14:37:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.837 uVs 14:37:09 Integrated Voltage Measurement... 14:37:18 Voltage Offset Correction: v_off_ini = 2827.091 uV, v_off_fin = 2821.896 uV 14:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.435 uVs 14:37:18 Integrated Voltage Measurement... 14:37:27 Voltage Offset Correction: v_off_ini = 2814.004 uV, v_off_fin = 2838.287 uV 14:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.157 uVs 14:37:27 Integrated Voltage Measurement... 14:37:36 Voltage Offset Correction: v_off_ini = 2849.924 uV, v_off_fin = 2831.968 uV 14:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.176 uVs 14:37:36 Integrated Voltage Measurement... 14:37:45 Voltage Offset Correction: v_off_ini = 2816.625 uV, v_off_fin = 2823.361 uV 14:37:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.521 uVs 14:37:47 I2Y Average and RMS of Measurements VT = -216.831 +- 9.538 uVs I2Y = -19.948 +- 0.877 uTm^2 14:37:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:37:56 Integrated Voltage Measurement... 14:38:05 Voltage Offset Correction: v_off_ini = 2821.159 uV, v_off_fin = 2832.497 uV 14:38:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -150.095 uVs 14:38:05 Integrated Voltage Measurement... 14:38:14 Voltage Offset Correction: v_off_ini = 2818.259 uV, v_off_fin = 2827.633 uV 14:38:14 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.646 uVs 14:38:14 Integrated Voltage Measurement... 14:38:23 Voltage Offset Correction: v_off_ini = 2807.464 uV, v_off_fin = 2799.970 uV 14:38:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -145.509 uVs 14:38:23 Integrated Voltage Measurement... 14:38:32 Voltage Offset Correction: v_off_ini = 2824.157 uV, v_off_fin = 2821.126 uV 14:38:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.789 uVs 14:38:32 Integrated Voltage Measurement... 14:38:41 Voltage Offset Correction: v_off_ini = 2824.162 uV, v_off_fin = 2821.111 uV 14:38:41 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.137 uVs 14:38:41 Integrated Voltage Measurement... 14:38:50 Voltage Offset Correction: v_off_ini = 2825.103 uV, v_off_fin = 2816.180 uV 14:38:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.664 uVs 14:38:54 I1X Average and RMS of Measurements VT = -132.973 +- 12.642 uVs I1X = 26.597 +- 2.528 uTm 14:38:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:39:01 Integrated Voltage Measurement... 14:39:09 Voltage Offset Correction: v_off_ini = 2826.987 uV, v_off_fin = 2809.452 uV 14:39:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.099 uVs 14:39:10 Integrated Voltage Measurement... 14:39:18 Voltage Offset Correction: v_off_ini = 2810.597 uV, v_off_fin = 2823.811 uV 14:39:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.889 uVs 14:39:19 Integrated Voltage Measurement... 14:39:27 Voltage Offset Correction: v_off_ini = 2835.028 uV, v_off_fin = 2809.386 uV 14:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.471 uVs 14:39:28 Integrated Voltage Measurement... 14:39:36 Voltage Offset Correction: v_off_ini = 2837.475 uV, v_off_fin = 2820.245 uV 14:39:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.848 uVs 14:39:37 Integrated Voltage Measurement... 14:39:45 Voltage Offset Correction: v_off_ini = 2813.023 uV, v_off_fin = 2790.350 uV 14:39:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.055 uVs 14:39:46 Integrated Voltage Measurement... 14:39:54 Voltage Offset Correction: v_off_ini = 2793.197 uV, v_off_fin = 2824.280 uV 14:39:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.829 uVs 14:39:59 I1Y Average and RMS of Measurements VT = -223.032 +- 1.975 uVs I1Y = -44.606 +- 0.395 uTm 14:40:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:40:04 Integrated Voltage Measurement... 14:40:13 Voltage Offset Correction: v_off_ini = 2780.871 uV, v_off_fin = 2771.320 uV 14:40:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.926 uVs 14:40:13 Integrated Voltage Measurement... 14:40:22 Voltage Offset Correction: v_off_ini = 2779.038 uV, v_off_fin = 2780.860 uV 14:40:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 75.295 uVs 14:40:22 Integrated Voltage Measurement... 14:40:31 Voltage Offset Correction: v_off_ini = 2784.624 uV, v_off_fin = 2745.149 uV 14:40:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.320 uVs 14:40:31 Integrated Voltage Measurement... 14:40:40 Voltage Offset Correction: v_off_ini = 2809.587 uV, v_off_fin = 2814.378 uV 14:40:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.825 uVs 14:40:40 Integrated Voltage Measurement... 14:40:49 Voltage Offset Correction: v_off_ini = 2818.129 uV, v_off_fin = 2786.820 uV 14:40:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.769 uVs 14:40:49 Integrated Voltage Measurement... 14:40:58 Voltage Offset Correction: v_off_ini = 2806.889 uV, v_off_fin = 2819.438 uV 14:40:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.123 uVs 14:41:00 I2X Average and RMS of Measurements VT = -86.043 +- 9.876 uVs I2X = 7.916 +- 0.909 uTm^2 14:41:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:41:05 Integrated Voltage Measurement... 14:41:14 Voltage Offset Correction: v_off_ini = 2781.358 uV, v_off_fin = 2776.600 uV 14:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.687 uVs 14:41:15 Integrated Voltage Measurement... 14:41:23 Voltage Offset Correction: v_off_ini = 2767.152 uV, v_off_fin = 2777.188 uV 14:41:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.188 uVs 14:41:24 Integrated Voltage Measurement... 14:41:33 Voltage Offset Correction: v_off_ini = 2795.016 uV, v_off_fin = 2781.131 uV 14:41:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.538 uVs 14:41:33 Integrated Voltage Measurement... 14:41:42 Voltage Offset Correction: v_off_ini = 2771.496 uV, v_off_fin = 2815.679 uV 14:41:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.786 uVs 14:41:42 Integrated Voltage Measurement... 14:41:51 Voltage Offset Correction: v_off_ini = 2803.308 uV, v_off_fin = 2800.484 uV 14:41:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.606 uVs 14:41:51 Integrated Voltage Measurement... 14:42:00 Voltage Offset Correction: v_off_ini = 2778.214 uV, v_off_fin = 2810.204 uV 14:42:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.667 uVs 14:42:02 I2Y Average and RMS of Measurements VT = -229.579 +- 13.099 uVs I2Y = -21.121 +- 1.205 uTm^2 14:42:06 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:10 Integrated Voltage Measurement... 14:42:19 Voltage Offset Correction: v_off_ini = 2780.089 uV, v_off_fin = 2762.531 uV 14:42:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -119.913 uVs 14:42:19 Integrated Voltage Measurement... 14:42:28 Voltage Offset Correction: v_off_ini = 2774.570 uV, v_off_fin = 2791.293 uV 14:42:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.391 uVs 14:42:28 Integrated Voltage Measurement... 14:42:37 Voltage Offset Correction: v_off_ini = 2781.978 uV, v_off_fin = 2768.408 uV 14:42:37 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -116.881 uVs 14:42:37 Integrated Voltage Measurement... 14:42:46 Voltage Offset Correction: v_off_ini = 2764.112 uV, v_off_fin = 2779.795 uV 14:42:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.986 uVs 14:42:46 Integrated Voltage Measurement... 14:42:55 Voltage Offset Correction: v_off_ini = 2773.607 uV, v_off_fin = 2757.470 uV 14:42:55 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = -117.396 uVs 14:42:55 Integrated Voltage Measurement... 14:43:04 Voltage Offset Correction: v_off_ini = 2770.506 uV, v_off_fin = 2775.702 uV 14:43:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.971 uVs 14:43:09 I1X Average and RMS of Measurements VT = -110.090 +- 5.029 uVs I1X = 22.021 +- 1.006 uTm 14:43:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:15 Integrated Voltage Measurement... 14:43:24 Voltage Offset Correction: v_off_ini = 2759.924 uV, v_off_fin = 2762.222 uV 14:43:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.445 uVs 14:43:24 Integrated Voltage Measurement... 14:43:33 Voltage Offset Correction: v_off_ini = 2761.941 uV, v_off_fin = 2780.395 uV 14:43:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.028 uVs 14:43:33 Integrated Voltage Measurement... 14:43:42 Voltage Offset Correction: v_off_ini = 2791.717 uV, v_off_fin = 2783.403 uV 14:43:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.962 uVs 14:43:42 Integrated Voltage Measurement... 14:43:51 Voltage Offset Correction: v_off_ini = 2788.457 uV, v_off_fin = 2792.540 uV 14:43:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.765 uVs 14:43:51 Integrated Voltage Measurement... 14:44:00 Voltage Offset Correction: v_off_ini = 2785.127 uV, v_off_fin = 2786.810 uV 14:44:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.577 uVs 14:44:00 Integrated Voltage Measurement... 14:44:09 Voltage Offset Correction: v_off_ini = 2787.262 uV, v_off_fin = 2796.653 uV 14:44:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.624 uVs 14:44:13 I1Y Average and RMS of Measurements VT = -221.900 +- 8.018 uVs I1Y = -44.380 +- 1.604 uTm 14:44:16 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:44:19 Integrated Voltage Measurement... 14:44:28 Voltage Offset Correction: v_off_ini = 2769.043 uV, v_off_fin = 2779.712 uV 14:44:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.782 uVs 14:44:28 Integrated Voltage Measurement... 14:44:37 Voltage Offset Correction: v_off_ini = 2776.003 uV, v_off_fin = 2790.463 uV 14:44:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.097 uVs 14:44:37 Integrated Voltage Measurement... 14:44:46 Voltage Offset Correction: v_off_ini = 2795.805 uV, v_off_fin = 2779.238 uV 14:44:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.700 uVs 14:44:46 Integrated Voltage Measurement... 14:44:55 Voltage Offset Correction: v_off_ini = 2767.735 uV, v_off_fin = 2756.076 uV 14:44:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.875 uVs 14:44:55 Integrated Voltage Measurement... 14:45:04 Voltage Offset Correction: v_off_ini = 2779.623 uV, v_off_fin = 2763.911 uV 14:45:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -76.659 uVs 14:45:04 Integrated Voltage Measurement... 14:45:13 Voltage Offset Correction: v_off_ini = 2757.272 uV, v_off_fin = 2784.108 uV 14:45:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.854 uVs 14:45:15 I2X Average and RMS of Measurements VT = -81.994 +- 7.084 uVs I2X = 7.543 +- 0.652 uTm^2 14:45:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:45:20 Integrated Voltage Measurement... 14:45:29 Voltage Offset Correction: v_off_ini = 2765.293 uV, v_off_fin = 2791.128 uV 14:45:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.374 uVs 14:45:29 Integrated Voltage Measurement... 14:45:38 Voltage Offset Correction: v_off_ini = 2773.322 uV, v_off_fin = 2767.471 uV 14:45:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.846 uVs 14:45:38 Integrated Voltage Measurement... 14:45:47 Voltage Offset Correction: v_off_ini = 2780.785 uV, v_off_fin = 2750.689 uV 14:45:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.298 uVs 14:45:47 Integrated Voltage Measurement... 14:45:56 Voltage Offset Correction: v_off_ini = 2799.104 uV, v_off_fin = 2813.951 uV 14:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 256.908 uVs 14:45:56 Integrated Voltage Measurement... 14:46:05 Voltage Offset Correction: v_off_ini = 2788.422 uV, v_off_fin = 2804.223 uV 14:46:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.671 uVs 14:46:05 Integrated Voltage Measurement... 14:46:14 Voltage Offset Correction: v_off_ini = 2787.750 uV, v_off_fin = 2813.692 uV 14:46:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.781 uVs 14:46:17 I2Y Average and RMS of Measurements VT = -228.646 +- 11.475 uVs I2Y = -21.035 +- 1.056 uTm^2 14:46:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:46:25 Integrated Voltage Measurement... 14:46:34 Voltage Offset Correction: v_off_ini = 2824.574 uV, v_off_fin = 2813.635 uV 14:46:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -163.742 uVs 14:46:34 Integrated Voltage Measurement... 14:46:43 Voltage Offset Correction: v_off_ini = 2813.559 uV, v_off_fin = 2810.795 uV 14:46:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.338 uVs 14:46:43 Integrated Voltage Measurement... 14:46:52 Voltage Offset Correction: v_off_ini = 2802.576 uV, v_off_fin = 2798.746 uV 14:46:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -91.558 uVs 14:46:52 Integrated Voltage Measurement... 14:47:01 Voltage Offset Correction: v_off_ini = 2795.718 uV, v_off_fin = 2793.509 uV 14:47:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 103.213 uVs 14:47:01 Integrated Voltage Measurement... 14:47:10 Voltage Offset Correction: v_off_ini = 2794.452 uV, v_off_fin = 2795.633 uV 14:47:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -130.817 uVs 14:47:10 Integrated Voltage Measurement... 14:47:19 Voltage Offset Correction: v_off_ini = 2818.127 uV, v_off_fin = 2822.088 uV 14:47:19 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.912 uVs 14:47:23 I1X Average and RMS of Measurements VT = -124.430 +- 19.412 uVs I1X = 24.889 +- 3.883 uTm 14:47:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:47:30 Integrated Voltage Measurement... 14:47:39 Voltage Offset Correction: v_off_ini = 2804.299 uV, v_off_fin = 2817.027 uV 14:47:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -229.015 uVs 14:47:39 Integrated Voltage Measurement... 14:47:48 Voltage Offset Correction: v_off_ini = 2858.058 uV, v_off_fin = 2858.418 uV 14:47:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 228.391 uVs 14:47:48 Integrated Voltage Measurement... 14:47:57 Voltage Offset Correction: v_off_ini = 2818.333 uV, v_off_fin = 2803.390 uV 14:47:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.079 uVs 14:47:57 Integrated Voltage Measurement... 14:48:06 Voltage Offset Correction: v_off_ini = 2789.861 uV, v_off_fin = 2806.552 uV 14:48:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 253.344 uVs 14:48:06 Integrated Voltage Measurement... 14:48:15 Voltage Offset Correction: v_off_ini = 2790.942 uV, v_off_fin = 2779.027 uV 14:48:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.969 uVs 14:48:15 Integrated Voltage Measurement... 14:48:24 Voltage Offset Correction: v_off_ini = 2791.649 uV, v_off_fin = 2816.016 uV 14:48:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.814 uVs 14:48:28 I1Y Average and RMS of Measurements VT = -229.435 +- 8.515 uVs I1Y = -45.883 +- 1.704 uTm 14:48:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:48:33 Integrated Voltage Measurement... 14:48:42 Voltage Offset Correction: v_off_ini = 2810.902 uV, v_off_fin = 2794.529 uV 14:48:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.924 uVs 14:48:42 Integrated Voltage Measurement... 14:48:51 Voltage Offset Correction: v_off_ini = 2806.934 uV, v_off_fin = 2816.942 uV 14:48:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 72.115 uVs 14:48:51 Integrated Voltage Measurement... 14:49:00 Voltage Offset Correction: v_off_ini = 2794.452 uV, v_off_fin = 2767.687 uV 14:49:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.333 uVs 14:49:00 Integrated Voltage Measurement... 14:49:09 Voltage Offset Correction: v_off_ini = 2789.455 uV, v_off_fin = 2798.096 uV 14:49:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.436 uVs 14:49:09 Integrated Voltage Measurement... 14:49:18 Voltage Offset Correction: v_off_ini = 2770.876 uV, v_off_fin = 2782.424 uV 14:49:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.306 uVs 14:49:18 Integrated Voltage Measurement... 14:49:27 Voltage Offset Correction: v_off_ini = 2794.265 uV, v_off_fin = 2783.985 uV 14:49:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.803 uVs 14:49:30 I2X Average and RMS of Measurements VT = -87.319 +- 3.679 uVs I2X = 8.033 +- 0.339 uTm^2 14:49:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:49:35 Integrated Voltage Measurement... 14:49:44 Voltage Offset Correction: v_off_ini = 2793.472 uV, v_off_fin = 2783.238 uV 14:49:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.921 uVs 14:49:44 Integrated Voltage Measurement... 14:49:53 Voltage Offset Correction: v_off_ini = 2778.197 uV, v_off_fin = 2788.351 uV 14:49:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.975 uVs 14:49:53 Integrated Voltage Measurement... 14:50:02 Voltage Offset Correction: v_off_ini = 2820.063 uV, v_off_fin = 2790.338 uV 14:50:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.077 uVs 14:50:02 Integrated Voltage Measurement... 14:50:11 Voltage Offset Correction: v_off_ini = 2796.226 uV, v_off_fin = 2792.812 uV 14:50:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.561 uVs 14:50:11 Integrated Voltage Measurement... 14:50:20 Voltage Offset Correction: v_off_ini = 2769.658 uV, v_off_fin = 2793.575 uV 14:50:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.323 uVs 14:50:20 Integrated Voltage Measurement... 14:50:29 Voltage Offset Correction: v_off_ini = 2789.871 uV, v_off_fin = 2787.174 uV 14:50:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.198 uVs 14:50:31 I2Y Average and RMS of Measurements VT = -210.009 +- 4.419 uVs I2Y = -19.321 +- 0.407 uTm^2 14:50:35 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:50:40 Integrated Voltage Measurement... 14:50:49 Voltage Offset Correction: v_off_ini = 2781.567 uV, v_off_fin = 2787.101 uV 14:50:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -121.802 uVs 14:50:49 Integrated Voltage Measurement... 14:50:58 Voltage Offset Correction: v_off_ini = 2772.474 uV, v_off_fin = 2781.346 uV 14:50:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.881 uVs 14:50:58 Integrated Voltage Measurement... 14:51:07 Voltage Offset Correction: v_off_ini = 2771.009 uV, v_off_fin = 2767.147 uV 14:51:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -132.788 uVs 14:51:07 Integrated Voltage Measurement... 14:51:16 Voltage Offset Correction: v_off_ini = 2753.239 uV, v_off_fin = 2755.729 uV 14:51:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 97.257 uVs 14:51:16 Integrated Voltage Measurement... 14:51:25 Voltage Offset Correction: v_off_ini = 2746.045 uV, v_off_fin = 2731.193 uV 14:51:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -96.821 uVs 14:51:25 Integrated Voltage Measurement... 14:51:34 Voltage Offset Correction: v_off_ini = 2785.177 uV, v_off_fin = 2774.824 uV 14:51:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 104.257 uVs 14:51:38 I1X Average and RMS of Measurements VT = -111.134 +- 7.580 uVs I1X = 22.230 +- 1.517 uTm 14:51:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:51:45 Integrated Voltage Measurement... 14:51:54 Voltage Offset Correction: v_off_ini = 2760.587 uV, v_off_fin = 2742.893 uV 14:51:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -220.480 uVs 14:51:54 Integrated Voltage Measurement... 14:52:02 Voltage Offset Correction: v_off_ini = 2751.354 uV, v_off_fin = 2766.557 uV 14:52:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.384 uVs 14:52:03 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 2753.334 uV, v_off_fin = 2742.157 uV 14:52:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.571 uVs 14:52:12 Integrated Voltage Measurement... 14:52:20 Voltage Offset Correction: v_off_ini = 2737.628 uV, v_off_fin = 2758.133 uV 14:52:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 209.137 uVs 14:52:21 Integrated Voltage Measurement... 14:52:29 Voltage Offset Correction: v_off_ini = 2744.946 uV, v_off_fin = 2725.952 uV 14:52:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -217.808 uVs 14:52:30 Integrated Voltage Measurement... 14:52:38 Voltage Offset Correction: v_off_ini = 2734.661 uV, v_off_fin = 2744.608 uV 14:52:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.321 uVs 14:52:43 I1Y Average and RMS of Measurements VT = -220.117 +- 4.782 uVs I1Y = -44.020 +- 0.957 uTm 14:52:45 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:52:48 Integrated Voltage Measurement... 14:52:57 Voltage Offset Correction: v_off_ini = 2735.910 uV, v_off_fin = 2723.871 uV 14:52:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.908 uVs 14:52:57 Integrated Voltage Measurement... 14:53:06 Voltage Offset Correction: v_off_ini = 2752.429 uV, v_off_fin = 2745.949 uV 14:53:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.518 uVs 14:53:06 Integrated Voltage Measurement... 14:53:15 Voltage Offset Correction: v_off_ini = 2754.163 uV, v_off_fin = 2732.785 uV 14:53:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -78.546 uVs 14:53:15 Integrated Voltage Measurement... 14:53:24 Voltage Offset Correction: v_off_ini = 2741.878 uV, v_off_fin = 2750.656 uV 14:53:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.539 uVs 14:53:24 Integrated Voltage Measurement... 14:53:33 Voltage Offset Correction: v_off_ini = 2730.986 uV, v_off_fin = 2710.865 uV 14:53:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.549 uVs 14:53:33 Integrated Voltage Measurement... 14:53:42 Voltage Offset Correction: v_off_ini = 2730.821 uV, v_off_fin = 2734.850 uV 14:53:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.227 uVs 14:53:44 I2X Average and RMS of Measurements VT = -75.881 +- 10.057 uVs I2X = 6.981 +- 0.925 uTm^2 14:53:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:53:49 Integrated Voltage Measurement... 14:53:58 Voltage Offset Correction: v_off_ini = 2720.415 uV, v_off_fin = 2718.217 uV 14:53:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.941 uVs 14:53:58 Integrated Voltage Measurement... 14:54:07 Voltage Offset Correction: v_off_ini = 2724.031 uV, v_off_fin = 2722.038 uV 14:54:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.831 uVs 14:54:07 Integrated Voltage Measurement... 14:54:16 Voltage Offset Correction: v_off_ini = 2718.844 uV, v_off_fin = 2730.037 uV 14:54:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.708 uVs 14:54:17 Integrated Voltage Measurement... 14:54:25 Voltage Offset Correction: v_off_ini = 2722.617 uV, v_off_fin = 2731.200 uV 14:54:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.231 uVs 14:54:26 Integrated Voltage Measurement... 14:54:35 Voltage Offset Correction: v_off_ini = 2727.197 uV, v_off_fin = 2723.793 uV 14:54:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.288 uVs 14:54:35 Integrated Voltage Measurement... 14:54:44 Voltage Offset Correction: v_off_ini = 2729.846 uV, v_off_fin = 2722.083 uV 14:54:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.849 uVs 14:54:46 I2Y Average and RMS of Measurements VT = -226.475 +- 7.424 uVs I2Y = -20.836 +- 0.683 uTm^2 14:55:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:55:07 Integrated Voltage Measurement... 14:55:16 Voltage Offset Correction: v_off_ini = 2738.316 uV, v_off_fin = 2721.500 uV 14:55:16 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -114.207 uVs 14:55:16 Integrated Voltage Measurement... 14:55:25 Voltage Offset Correction: v_off_ini = 2709.230 uV, v_off_fin = 2731.469 uV 14:55:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 115.463 uVs 14:55:25 Integrated Voltage Measurement... 14:55:34 Voltage Offset Correction: v_off_ini = 2733.355 uV, v_off_fin = 2725.111 uV 14:55:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.775 uVs 14:55:34 Integrated Voltage Measurement... 14:55:43 Voltage Offset Correction: v_off_ini = 2717.142 uV, v_off_fin = 2715.619 uV 14:55:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.345 uVs 14:55:43 Integrated Voltage Measurement... 14:55:52 Voltage Offset Correction: v_off_ini = 2711.195 uV, v_off_fin = 2702.259 uV 14:55:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.969 uVs 14:55:52 Integrated Voltage Measurement... 14:56:01 Voltage Offset Correction: v_off_ini = 2712.164 uV, v_off_fin = 2703.209 uV 14:56:01 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 145.629 uVs 14:56:05 I1X Average and RMS of Measurements VT = -128.231 +- 9.566 uVs I1X = 25.649 +- 1.910 uTm 14:56:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:56:12 Integrated Voltage Measurement... 14:56:21 Voltage Offset Correction: v_off_ini = 2670.925 uV, v_off_fin = 2664.553 uV 14:56:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.853 uVs 14:56:21 Integrated Voltage Measurement... 14:56:30 Voltage Offset Correction: v_off_ini = 2673.042 uV, v_off_fin = 2679.144 uV 14:56:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.924 uVs 14:56:30 Integrated Voltage Measurement... 14:56:39 Voltage Offset Correction: v_off_ini = 2672.701 uV, v_off_fin = 2670.904 uV 14:56:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.846 uVs 14:56:39 Integrated Voltage Measurement... 14:56:48 Voltage Offset Correction: v_off_ini = 2664.609 uV, v_off_fin = 2668.586 uV 14:56:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.798 uVs 14:56:48 Integrated Voltage Measurement... 14:56:57 Voltage Offset Correction: v_off_ini = 2688.247 uV, v_off_fin = 2656.641 uV 14:56:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.075 uVs 14:56:57 Integrated Voltage Measurement... 14:57:06 Voltage Offset Correction: v_off_ini = 2644.668 uV, v_off_fin = 2684.825 uV 14:57:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 198.188 uVs 14:57:10 I1Y Average and RMS of Measurements VT = -203.114 +- 1.048 uVs I1Y = -40.623 +- 0.210 uTm 14:57:15 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:57:18 Integrated Voltage Measurement... 14:57:27 Voltage Offset Correction: v_off_ini = 2654.070 uV, v_off_fin = 2659.735 uV 14:57:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.451 uVs 14:57:27 Integrated Voltage Measurement... 14:57:36 Voltage Offset Correction: v_off_ini = 2663.319 uV, v_off_fin = 2670.849 uV 14:57:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 124.992 uVs 14:57:36 Integrated Voltage Measurement... 14:57:45 Voltage Offset Correction: v_off_ini = 2646.366 uV, v_off_fin = 2659.445 uV 14:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -81.895 uVs 14:57:45 Integrated Voltage Measurement... 14:57:54 Voltage Offset Correction: v_off_ini = 2647.713 uV, v_off_fin = 2667.804 uV 14:57:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.415 uVs 14:57:54 Integrated Voltage Measurement... 14:58:03 Voltage Offset Correction: v_off_ini = 2673.871 uV, v_off_fin = 2661.698 uV 14:58:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.461 uVs 14:58:03 Integrated Voltage Measurement... 14:58:12 Voltage Offset Correction: v_off_ini = 2658.876 uV, v_off_fin = 2673.080 uV 14:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 120.584 uVs 14:58:15 I2X Average and RMS of Measurements VT = -109.633 +- 11.298 uVs I2X = 10.086 +- 1.039 uTm^2 14:58:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:58:22 Integrated Voltage Measurement... 14:58:31 Voltage Offset Correction: v_off_ini = 2642.870 uV, v_off_fin = 2626.220 uV 14:58:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.689 uVs 14:58:31 Integrated Voltage Measurement... 14:58:40 Voltage Offset Correction: v_off_ini = 2649.831 uV, v_off_fin = 2643.030 uV 14:58:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.162 uVs 14:58:40 Integrated Voltage Measurement... 14:58:49 Voltage Offset Correction: v_off_ini = 2619.010 uV, v_off_fin = 2662.543 uV 14:58:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -139.996 uVs 14:58:49 Integrated Voltage Measurement... 14:58:58 Voltage Offset Correction: v_off_ini = 2650.810 uV, v_off_fin = 2653.993 uV 14:58:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 161.015 uVs 14:58:58 Integrated Voltage Measurement... 14:59:07 Voltage Offset Correction: v_off_ini = 2660.470 uV, v_off_fin = 2662.025 uV 14:59:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.118 uVs 14:59:07 Integrated Voltage Measurement... 14:59:16 Voltage Offset Correction: v_off_ini = 2655.927 uV, v_off_fin = 2676.022 uV 14:59:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.658 uVs 14:59:19 I2Y Average and RMS of Measurements VT = -188.773 +- 30.607 uVs I2Y = -17.367 +- 2.816 uTm^2 14:59:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:59:28 Integrated Voltage Measurement... 14:59:37 Voltage Offset Correction: v_off_ini = 2688.564 uV, v_off_fin = 2682.006 uV 14:59:37 Integrated Voltage Measurement dXYus = -0.4998 mm, dXYds = -0.4997 mm dXY = -0.4997 mm VT = -152.942 uVs 14:59:37 Integrated Voltage Measurement... 14:59:46 Voltage Offset Correction: v_off_ini = 2693.201 uV, v_off_fin = 2703.341 uV 14:59:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4998 mm dXY = 0.4999 mm VT = 171.362 uVs 14:59:46 Integrated Voltage Measurement... 14:59:55 Voltage Offset Correction: v_off_ini = 2686.053 uV, v_off_fin = 2700.792 uV 14:59:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -107.413 uVs 14:59:55 Integrated Voltage Measurement... 15:00:04 Voltage Offset Correction: v_off_ini = 2693.578 uV, v_off_fin = 2699.288 uV 15:00:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.463 uVs 15:00:04 Integrated Voltage Measurement... 15:00:13 Voltage Offset Correction: v_off_ini = 2713.220 uV, v_off_fin = 2699.688 uV 15:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.729 uVs 15:00:13 Integrated Voltage Measurement... 15:00:22 Voltage Offset Correction: v_off_ini = 2706.491 uV, v_off_fin = 2701.316 uV 15:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.380 uVs 15:00:26 I1X Average and RMS of Measurements VT = -135.715 +- 18.697 uVs I1X = 27.147 +- 3.744 uTm 15:00:28 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:00:33 Integrated Voltage Measurement... 15:00:42 Voltage Offset Correction: v_off_ini = 2686.142 uV, v_off_fin = 2714.323 uV 15:00:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.310 uVs 15:00:42 Integrated Voltage Measurement... 15:00:51 Voltage Offset Correction: v_off_ini = 2716.298 uV, v_off_fin = 2720.667 uV 15:00:51 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.000 uVs 15:00:51 Integrated Voltage Measurement... 15:00:59 Voltage Offset Correction: v_off_ini = 2680.294 uV, v_off_fin = 2701.860 uV 15:01:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.008 uVs 15:01:00 Integrated Voltage Measurement... 15:01:08 Voltage Offset Correction: v_off_ini = 2711.611 uV, v_off_fin = 2727.268 uV 15:01:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.320 uVs 15:01:09 Integrated Voltage Measurement... 15:01:17 Voltage Offset Correction: v_off_ini = 2709.399 uV, v_off_fin = 2701.132 uV 15:01:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.571 uVs 15:01:18 Integrated Voltage Measurement... 15:01:26 Voltage Offset Correction: v_off_ini = 2696.372 uV, v_off_fin = 2717.261 uV 15:01:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.691 uVs 15:01:31 I1Y Average and RMS of Measurements VT = -206.483 +- 7.032 uVs I1Y = -41.297 +- 1.405 uTm 15:01:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:01:38 Integrated Voltage Measurement... 15:01:47 Voltage Offset Correction: v_off_ini = 2698.723 uV, v_off_fin = 2687.490 uV 15:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.907 uVs 15:01:47 Integrated Voltage Measurement... 15:01:56 Voltage Offset Correction: v_off_ini = 2738.598 uV, v_off_fin = 2739.559 uV 15:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.122 uVs 15:01:56 Integrated Voltage Measurement... 15:02:05 Voltage Offset Correction: v_off_ini = 2777.760 uV, v_off_fin = 2745.327 uV 15:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.331 uVs 15:02:05 Integrated Voltage Measurement... 15:02:14 Voltage Offset Correction: v_off_ini = 2751.463 uV, v_off_fin = 2748.279 uV 15:02:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.274 uVs 15:02:14 Integrated Voltage Measurement... 15:02:23 Voltage Offset Correction: v_off_ini = 2755.928 uV, v_off_fin = 2744.241 uV 15:02:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.390 uVs 15:02:23 Integrated Voltage Measurement... 15:02:32 Voltage Offset Correction: v_off_ini = 2736.297 uV, v_off_fin = 2742.835 uV 15:02:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.161 uVs 15:02:35 I2X Average and RMS of Measurements VT = -104.531 +- 3.055 uVs I2X = 9.617 +- 0.281 uTm^2 15:02:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:02:42 Integrated Voltage Measurement... 15:02:51 Voltage Offset Correction: v_off_ini = 2741.573 uV, v_off_fin = 2743.931 uV 15:02:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.536 uVs 15:02:52 Integrated Voltage Measurement... 15:03:00 Voltage Offset Correction: v_off_ini = 2740.239 uV, v_off_fin = 2735.429 uV 15:03:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.700 uVs 15:03:01 Integrated Voltage Measurement... 15:03:10 Voltage Offset Correction: v_off_ini = 2715.929 uV, v_off_fin = 2715.780 uV 15:03:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.849 uVs 15:03:10 Integrated Voltage Measurement... 15:03:19 Voltage Offset Correction: v_off_ini = 2697.141 uV, v_off_fin = 2725.907 uV 15:03:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.823 uVs 15:03:19 Integrated Voltage Measurement... 15:03:28 Voltage Offset Correction: v_off_ini = 2715.840 uV, v_off_fin = 2731.138 uV 15:03:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.568 uVs 15:03:28 Integrated Voltage Measurement... 15:03:37 Voltage Offset Correction: v_off_ini = 2733.282 uV, v_off_fin = 2722.099 uV 15:03:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.223 uVs 15:03:39 I2Y Average and RMS of Measurements VT = -200.783 +- 8.834 uVs I2Y = -18.472 +- 0.813 uTm^2 15:03:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:48 Integrated Voltage Measurement... 15:03:57 Voltage Offset Correction: v_off_ini = 2745.990 uV, v_off_fin = 2726.622 uV 15:03:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.868 uVs 15:03:57 Integrated Voltage Measurement... 15:04:06 Voltage Offset Correction: v_off_ini = 2752.243 uV, v_off_fin = 2747.942 uV 15:04:06 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.773 uVs 15:04:06 Integrated Voltage Measurement... 15:04:15 Voltage Offset Correction: v_off_ini = 2760.726 uV, v_off_fin = 2750.169 uV 15:04:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.212 uVs 15:04:15 Integrated Voltage Measurement... 15:04:24 Voltage Offset Correction: v_off_ini = 2754.016 uV, v_off_fin = 2787.945 uV 15:04:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.644 uVs 15:04:24 Integrated Voltage Measurement... 15:04:33 Voltage Offset Correction: v_off_ini = 2737.278 uV, v_off_fin = 2737.006 uV 15:04:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.688 uVs 15:04:33 Integrated Voltage Measurement... 15:04:42 Voltage Offset Correction: v_off_ini = 2735.556 uV, v_off_fin = 2708.438 uV 15:04:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.688 uVs 15:04:46 I1X Average and RMS of Measurements VT = -135.479 +- 7.820 uVs I1X = 27.096 +- 1.565 uTm 15:04:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:53 Integrated Voltage Measurement... 15:05:02 Voltage Offset Correction: v_off_ini = 2724.423 uV, v_off_fin = 2711.806 uV 15:05:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -224.815 uVs 15:05:02 Integrated Voltage Measurement... 15:05:11 Voltage Offset Correction: v_off_ini = 2714.294 uV, v_off_fin = 2725.450 uV 15:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.265 uVs 15:05:11 Integrated Voltage Measurement... 15:05:20 Voltage Offset Correction: v_off_ini = 2712.248 uV, v_off_fin = 2714.525 uV 15:05:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.934 uVs 15:05:20 Integrated Voltage Measurement... 15:05:29 Voltage Offset Correction: v_off_ini = 2698.182 uV, v_off_fin = 2719.350 uV 15:05:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.556 uVs 15:05:29 Integrated Voltage Measurement... 15:05:38 Voltage Offset Correction: v_off_ini = 2743.517 uV, v_off_fin = 2723.341 uV 15:05:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.607 uVs 15:05:38 Integrated Voltage Measurement... 15:05:47 Voltage Offset Correction: v_off_ini = 2697.913 uV, v_off_fin = 2718.586 uV 15:05:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.257 uVs 15:05:51 I1Y Average and RMS of Measurements VT = -212.906 +- 2.269 uVs I1Y = -42.582 +- 0.455 uTm 15:05:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:59 Integrated Voltage Measurement... 15:06:08 Voltage Offset Correction: v_off_ini = 2700.967 uV, v_off_fin = 2692.871 uV 15:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.101 uVs 15:06:08 Integrated Voltage Measurement... 15:06:17 Voltage Offset Correction: v_off_ini = 2705.544 uV, v_off_fin = 2707.079 uV 15:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.889 uVs 15:06:17 Integrated Voltage Measurement... 15:06:26 Voltage Offset Correction: v_off_ini = 2682.106 uV, v_off_fin = 2687.402 uV 15:06:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -83.530 uVs 15:06:26 Integrated Voltage Measurement... 15:06:35 Voltage Offset Correction: v_off_ini = 2712.068 uV, v_off_fin = 2715.957 uV 15:06:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.726 uVs 15:06:35 Integrated Voltage Measurement... 15:06:44 Voltage Offset Correction: v_off_ini = 2706.221 uV, v_off_fin = 2697.761 uV 15:06:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -103.279 uVs 15:06:44 Integrated Voltage Measurement... 15:06:53 Voltage Offset Correction: v_off_ini = 2741.555 uV, v_off_fin = 2750.900 uV 15:06:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.218 uVs 15:06:55 I2X Average and RMS of Measurements VT = -91.124 +- 13.753 uVs I2X = 8.384 +- 1.265 uTm^2 15:07:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:07:03 Integrated Voltage Measurement... 15:07:12 Voltage Offset Correction: v_off_ini = 2728.127 uV, v_off_fin = 2720.931 uV 15:07:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.427 uVs 15:07:12 Integrated Voltage Measurement... 15:07:21 Voltage Offset Correction: v_off_ini = 2727.457 uV, v_off_fin = 2735.425 uV 15:07:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.735 uVs 15:07:21 Integrated Voltage Measurement... 15:07:30 Voltage Offset Correction: v_off_ini = 2735.384 uV, v_off_fin = 2738.607 uV 15:07:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.024 uVs 15:07:30 Integrated Voltage Measurement... 15:07:39 Voltage Offset Correction: v_off_ini = 2764.610 uV, v_off_fin = 2747.467 uV 15:07:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.150 uVs 15:07:39 Integrated Voltage Measurement... 15:07:48 Voltage Offset Correction: v_off_ini = 2745.144 uV, v_off_fin = 2736.042 uV 15:07:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.396 uVs 15:07:48 Integrated Voltage Measurement... 15:07:57 Voltage Offset Correction: v_off_ini = 2726.504 uV, v_off_fin = 2747.248 uV 15:07:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.741 uVs 15:07:59 I2Y Average and RMS of Measurements VT = -208.745 +- 10.887 uVs I2Y = -19.205 +- 1.002 uTm^2 15:08:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:08:08 Integrated Voltage Measurement... 15:08:17 Voltage Offset Correction: v_off_ini = 2742.278 uV, v_off_fin = 2726.689 uV 15:08:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -135.725 uVs 15:08:17 Integrated Voltage Measurement... 15:08:26 Voltage Offset Correction: v_off_ini = 2718.671 uV, v_off_fin = 2711.629 uV 15:08:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.243 uVs 15:08:26 Integrated Voltage Measurement... 15:08:35 Voltage Offset Correction: v_off_ini = 2711.321 uV, v_off_fin = 2685.755 uV 15:08:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.962 uVs 15:08:35 Integrated Voltage Measurement... 15:08:44 Voltage Offset Correction: v_off_ini = 2678.676 uV, v_off_fin = 2692.154 uV 15:08:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 150.412 uVs 15:08:44 Integrated Voltage Measurement... 15:08:53 Voltage Offset Correction: v_off_ini = 2667.519 uV, v_off_fin = 2684.294 uV 15:08:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.302 uVs 15:08:53 Integrated Voltage Measurement... 15:09:02 Voltage Offset Correction: v_off_ini = 2675.181 uV, v_off_fin = 2669.207 uV 15:09:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.132 uVs 15:09:06 I1X Average and RMS of Measurements VT = -136.796 +- 6.040 uVs I1X = 27.360 +- 1.209 uTm 15:09:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:09:13 Integrated Voltage Measurement... 15:09:22 Voltage Offset Correction: v_off_ini = 2675.723 uV, v_off_fin = 2679.001 uV 15:09:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.754 uVs 15:09:22 Integrated Voltage Measurement... 15:09:31 Voltage Offset Correction: v_off_ini = 2689.794 uV, v_off_fin = 2701.357 uV 15:09:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.875 uVs 15:09:31 Integrated Voltage Measurement... 15:09:40 Voltage Offset Correction: v_off_ini = 2692.072 uV, v_off_fin = 2677.866 uV 15:09:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.462 uVs 15:09:40 Integrated Voltage Measurement... 15:09:49 Voltage Offset Correction: v_off_ini = 2713.433 uV, v_off_fin = 2729.892 uV 15:09:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.332 uVs 15:09:49 Integrated Voltage Measurement... 15:09:58 Voltage Offset Correction: v_off_ini = 2737.749 uV, v_off_fin = 2714.016 uV 15:09:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.929 uVs 15:09:58 Integrated Voltage Measurement... 15:10:07 Voltage Offset Correction: v_off_ini = 2691.885 uV, v_off_fin = 2707.293 uV 15:10:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.348 uVs 15:10:11 I1Y Average and RMS of Measurements VT = -219.783 +- 4.979 uVs I1Y = -43.957 +- 0.996 uTm 15:10:16 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:10:19 Integrated Voltage Measurement... 15:10:28 Voltage Offset Correction: v_off_ini = 2705.864 uV, v_off_fin = 2678.671 uV 15:10:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.724 uVs 15:10:28 Integrated Voltage Measurement... 15:10:37 Voltage Offset Correction: v_off_ini = 2695.778 uV, v_off_fin = 2719.840 uV 15:10:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.594 uVs 15:10:37 Integrated Voltage Measurement... 15:10:46 Voltage Offset Correction: v_off_ini = 2709.973 uV, v_off_fin = 2696.043 uV 15:10:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.031 uVs 15:10:46 Integrated Voltage Measurement... 15:10:55 Voltage Offset Correction: v_off_ini = 2716.688 uV, v_off_fin = 2714.376 uV 15:10:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 95.693 uVs 15:10:55 Integrated Voltage Measurement... 15:11:04 Voltage Offset Correction: v_off_ini = 2690.316 uV, v_off_fin = 2698.071 uV 15:11:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.105 uVs 15:11:04 Integrated Voltage Measurement... 15:11:13 Voltage Offset Correction: v_off_ini = 2706.251 uV, v_off_fin = 2720.748 uV 15:11:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.699 uVs 15:11:16 I2X Average and RMS of Measurements VT = -96.641 +- 10.560 uVs I2X = 8.891 +- 0.972 uTm^2 15:11:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:11:23 Integrated Voltage Measurement... 15:11:32 Voltage Offset Correction: v_off_ini = 2704.878 uV, v_off_fin = 2720.622 uV 15:11:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -231.372 uVs 15:11:32 Integrated Voltage Measurement... 15:11:41 Voltage Offset Correction: v_off_ini = 2741.282 uV, v_off_fin = 2718.173 uV 15:11:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 231.732 uVs 15:11:41 Integrated Voltage Measurement... 15:11:50 Voltage Offset Correction: v_off_ini = 2703.327 uV, v_off_fin = 2700.604 uV 15:11:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.332 uVs 15:11:50 Integrated Voltage Measurement... 15:11:59 Voltage Offset Correction: v_off_ini = 2707.771 uV, v_off_fin = 2702.199 uV 15:11:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 213.611 uVs 15:11:59 Integrated Voltage Measurement... 15:12:08 Voltage Offset Correction: v_off_ini = 2726.482 uV, v_off_fin = 2723.906 uV 15:12:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.097 uVs 15:12:08 Integrated Voltage Measurement... 15:12:17 Voltage Offset Correction: v_off_ini = 2726.917 uV, v_off_fin = 2730.563 uV 15:12:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.606 uVs 15:12:20 I2Y Average and RMS of Measurements VT = -217.625 +- 10.889 uVs I2Y = -20.021 +- 1.002 uTm^2 15:12:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:12:29 Integrated Voltage Measurement... 15:12:38 Voltage Offset Correction: v_off_ini = 2742.661 uV, v_off_fin = 2725.121 uV 15:12:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.284 uVs 15:12:38 Integrated Voltage Measurement... 15:12:47 Voltage Offset Correction: v_off_ini = 2720.943 uV, v_off_fin = 2738.719 uV 15:12:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.901 uVs 15:12:47 Integrated Voltage Measurement... 15:12:56 Voltage Offset Correction: v_off_ini = 2717.865 uV, v_off_fin = 2711.109 uV 15:12:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.313 uVs 15:12:56 Integrated Voltage Measurement... 15:13:05 Voltage Offset Correction: v_off_ini = 2744.371 uV, v_off_fin = 2759.026 uV 15:13:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 151.614 uVs 15:13:05 Integrated Voltage Measurement... 15:13:14 Voltage Offset Correction: v_off_ini = 2751.490 uV, v_off_fin = 2741.421 uV 15:13:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -134.367 uVs 15:13:14 Integrated Voltage Measurement... 15:13:23 Voltage Offset Correction: v_off_ini = 2744.107 uV, v_off_fin = 2737.217 uV 15:13:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.303 uVs 15:13:27 I1X Average and RMS of Measurements VT = -133.964 +- 1.505 uVs I1X = 26.793 +- 0.301 uTm 15:13:29 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:13:34 Integrated Voltage Measurement... 15:13:43 Voltage Offset Correction: v_off_ini = 2754.339 uV, v_off_fin = 2737.058 uV 15:13:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.202 uVs 15:13:43 Integrated Voltage Measurement... 15:13:52 Voltage Offset Correction: v_off_ini = 2765.769 uV, v_off_fin = 2778.885 uV 15:13:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.954 uVs 15:13:52 Integrated Voltage Measurement... 15:14:01 Voltage Offset Correction: v_off_ini = 2760.316 uV, v_off_fin = 2759.142 uV 15:14:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.877 uVs 15:14:01 Integrated Voltage Measurement... 15:14:10 Voltage Offset Correction: v_off_ini = 2753.940 uV, v_off_fin = 2769.000 uV 15:14:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.180 uVs 15:14:10 Integrated Voltage Measurement... 15:14:19 Voltage Offset Correction: v_off_ini = 2776.380 uV, v_off_fin = 2742.664 uV 15:14:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.638 uVs 15:14:19 Integrated Voltage Measurement... 15:14:28 Voltage Offset Correction: v_off_ini = 2732.231 uV, v_off_fin = 2760.861 uV 15:14:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.404 uVs 15:14:32 I1Y Average and RMS of Measurements VT = -226.042 +- 3.624 uVs I1Y = -45.208 +- 0.725 uTm 15:14:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:14:39 Integrated Voltage Measurement... 15:14:48 Voltage Offset Correction: v_off_ini = 2727.153 uV, v_off_fin = 2707.913 uV 15:14:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.484 uVs 15:14:48 Integrated Voltage Measurement... 15:14:57 Voltage Offset Correction: v_off_ini = 2741.851 uV, v_off_fin = 2733.413 uV 15:14:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 97.311 uVs 15:14:58 Integrated Voltage Measurement... 15:15:06 Voltage Offset Correction: v_off_ini = 2717.580 uV, v_off_fin = 2713.684 uV 15:15:07 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -75.638 uVs 15:15:07 Integrated Voltage Measurement... 15:15:16 Voltage Offset Correction: v_off_ini = 2715.567 uV, v_off_fin = 2719.549 uV 15:15:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 90.571 uVs 15:15:16 Integrated Voltage Measurement... 15:15:25 Voltage Offset Correction: v_off_ini = 2737.992 uV, v_off_fin = 2711.929 uV 15:15:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -102.882 uVs 15:15:25 Integrated Voltage Measurement... 15:15:34 Voltage Offset Correction: v_off_ini = 2720.415 uV, v_off_fin = 2729.685 uV 15:15:34 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 94.107 uVs 15:15:36 I2X Average and RMS of Measurements VT = -96.166 +- 9.852 uVs I2X = 8.848 +- 0.906 uTm^2 15:15:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:15:44 Integrated Voltage Measurement... 15:15:53 Voltage Offset Correction: v_off_ini = 2736.342 uV, v_off_fin = 2739.628 uV 15:15:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.865 uVs 15:15:53 Integrated Voltage Measurement... 15:16:02 Voltage Offset Correction: v_off_ini = 2726.300 uV, v_off_fin = 2724.589 uV 15:16:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.568 uVs 15:16:02 Integrated Voltage Measurement... 15:16:11 Voltage Offset Correction: v_off_ini = 2733.664 uV, v_off_fin = 2714.789 uV 15:16:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.260 uVs 15:16:11 Integrated Voltage Measurement... 15:16:20 Voltage Offset Correction: v_off_ini = 2711.907 uV, v_off_fin = 2741.804 uV 15:16:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.568 uVs 15:16:20 Integrated Voltage Measurement... 15:16:29 Voltage Offset Correction: v_off_ini = 2748.284 uV, v_off_fin = 2757.807 uV 15:16:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.894 uVs 15:16:29 Integrated Voltage Measurement... 15:16:38 Voltage Offset Correction: v_off_ini = 2756.255 uV, v_off_fin = 2749.776 uV 15:16:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.442 uVs 15:16:40 I2Y Average and RMS of Measurements VT = -215.599 +- 11.761 uVs I2Y = -19.835 +- 1.082 uTm^2 15:16:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:16:52 Integrated Voltage Measurement... 15:17:01 Voltage Offset Correction: v_off_ini = 2724.656 uV, v_off_fin = 2721.595 uV 15:17:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -157.103 uVs 15:17:01 Integrated Voltage Measurement... 15:17:10 Voltage Offset Correction: v_off_ini = 2723.757 uV, v_off_fin = 2720.842 uV 15:17:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 124.352 uVs 15:17:10 Integrated Voltage Measurement... 15:17:19 Voltage Offset Correction: v_off_ini = 2708.202 uV, v_off_fin = 2707.879 uV 15:17:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -109.854 uVs 15:17:19 Integrated Voltage Measurement... 15:17:28 Voltage Offset Correction: v_off_ini = 2740.293 uV, v_off_fin = 2730.471 uV 15:17:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.333 uVs 15:17:28 Integrated Voltage Measurement... 15:17:37 Voltage Offset Correction: v_off_ini = 2712.302 uV, v_off_fin = 2718.090 uV 15:17:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.282 uVs 15:17:37 Integrated Voltage Measurement... 15:17:46 Voltage Offset Correction: v_off_ini = 2709.125 uV, v_off_fin = 2716.906 uV 15:17:46 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 126.018 uVs 15:17:50 I1X Average and RMS of Measurements VT = -131.824 +- 8.657 uVs I1X = 26.366 +- 1.732 uTm 15:17:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:17:57 Integrated Voltage Measurement... 15:18:06 Voltage Offset Correction: v_off_ini = 2690.113 uV, v_off_fin = 2692.814 uV 15:18:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.287 uVs 15:18:06 Integrated Voltage Measurement... 15:18:15 Voltage Offset Correction: v_off_ini = 2724.601 uV, v_off_fin = 2718.858 uV 15:18:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.074 uVs 15:18:15 Integrated Voltage Measurement... 15:18:24 Voltage Offset Correction: v_off_ini = 2717.874 uV, v_off_fin = 2715.140 uV 15:18:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.414 uVs 15:18:24 Integrated Voltage Measurement... 15:18:33 Voltage Offset Correction: v_off_ini = 2697.987 uV, v_off_fin = 2727.230 uV 15:18:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.531 uVs 15:18:33 Integrated Voltage Measurement... 15:18:42 Voltage Offset Correction: v_off_ini = 2703.139 uV, v_off_fin = 2702.555 uV 15:18:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.562 uVs 15:18:42 Integrated Voltage Measurement... 15:18:51 Voltage Offset Correction: v_off_ini = 2735.302 uV, v_off_fin = 2738.916 uV 15:18:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.625 uVs 15:18:55 I1Y Average and RMS of Measurements VT = -217.416 +- 5.476 uVs I1Y = -43.483 +- 1.095 uTm 15:18:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:19:00 Integrated Voltage Measurement... 15:19:09 Voltage Offset Correction: v_off_ini = 2760.323 uV, v_off_fin = 2731.439 uV 15:19:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.759 uVs 15:19:09 Integrated Voltage Measurement... 15:19:18 Voltage Offset Correction: v_off_ini = 2732.272 uV, v_off_fin = 2740.311 uV 15:19:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.926 uVs 15:19:18 Integrated Voltage Measurement... 15:19:27 Voltage Offset Correction: v_off_ini = 2733.566 uV, v_off_fin = 2726.295 uV 15:19:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.312 uVs 15:19:27 Integrated Voltage Measurement... 15:19:36 Voltage Offset Correction: v_off_ini = 2729.042 uV, v_off_fin = 2739.291 uV 15:19:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.543 uVs 15:19:36 Integrated Voltage Measurement... 15:19:45 Voltage Offset Correction: v_off_ini = 2720.048 uV, v_off_fin = 2724.306 uV 15:19:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.094 uVs 15:19:45 Integrated Voltage Measurement... 15:19:54 Voltage Offset Correction: v_off_ini = 2742.882 uV, v_off_fin = 2738.272 uV 15:19:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.980 uVs 15:19:57 I2X Average and RMS of Measurements VT = -97.936 +- 5.582 uVs I2X = 9.010 +- 0.514 uTm^2 15:19:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 15:20:02 Integrated Voltage Measurement... 15:20:11 Voltage Offset Correction: v_off_ini = 2719.450 uV, v_off_fin = 2729.503 uV 15:20:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.607 uVs 15:20:11 Integrated Voltage Measurement... 15:20:20 Voltage Offset Correction: v_off_ini = 2720.083 uV, v_off_fin = 2747.352 uV 15:20:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 230.460 uVs 15:20:20 Integrated Voltage Measurement... 15:20:29 Voltage Offset Correction: v_off_ini = 2743.448 uV, v_off_fin = 2730.727 uV 15:20:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -228.614 uVs 15:20:29 Integrated Voltage Measurement... 15:20:38 Voltage Offset Correction: v_off_ini = 2741.044 uV, v_off_fin = 2729.821 uV 15:20:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.853 uVs 15:20:38 Integrated Voltage Measurement... 15:20:47 Voltage Offset Correction: v_off_ini = 2733.664 uV, v_off_fin = 2724.273 uV 15:20:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.461 uVs 15:20:47 Integrated Voltage Measurement... 15:20:56 Voltage Offset Correction: v_off_ini = 2732.873 uV, v_off_fin = 2752.516 uV 15:20:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.941 uVs 15:20:59 I2Y Average and RMS of Measurements VT = -224.823 +- 0.558 uVs I2Y = -20.684 +- 0.051 uTm^2 15:21:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:21:07 Integrated Voltage Measurement... 15:21:16 Voltage Offset Correction: v_off_ini = 2721.929 uV, v_off_fin = 2724.347 uV 15:21:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -150.294 uVs 15:21:16 Integrated Voltage Measurement... 15:21:25 Voltage Offset Correction: v_off_ini = 2740.316 uV, v_off_fin = 2719.306 uV 15:21:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 139.451 uVs 15:21:25 Integrated Voltage Measurement... 15:21:34 Voltage Offset Correction: v_off_ini = 2730.486 uV, v_off_fin = 2728.163 uV 15:21:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -120.094 uVs 15:21:34 Integrated Voltage Measurement... 15:21:43 Voltage Offset Correction: v_off_ini = 2732.640 uV, v_off_fin = 2733.183 uV 15:21:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.163 uVs 15:21:43 Integrated Voltage Measurement... 15:21:52 Voltage Offset Correction: v_off_ini = 2741.026 uV, v_off_fin = 2736.261 uV 15:21:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -114.348 uVs 15:21:52 Integrated Voltage Measurement... 15:22:01 Voltage Offset Correction: v_off_ini = 2773.795 uV, v_off_fin = 2757.788 uV 15:22:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.784 uVs 15:22:05 I1X Average and RMS of Measurements VT = -132.689 +- 8.615 uVs I1X = 26.538 +- 1.723 uTm 15:22:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:22:12 Integrated Voltage Measurement... 15:22:21 Voltage Offset Correction: v_off_ini = 2763.894 uV, v_off_fin = 2759.389 uV 15:22:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.284 uVs 15:22:21 Integrated Voltage Measurement... 15:22:30 Voltage Offset Correction: v_off_ini = 2758.730 uV, v_off_fin = 2771.590 uV 15:22:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.923 uVs 15:22:30 Integrated Voltage Measurement... 15:22:39 Voltage Offset Correction: v_off_ini = 2792.155 uV, v_off_fin = 2769.127 uV 15:22:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.858 uVs 15:22:39 Integrated Voltage Measurement... 15:22:48 Voltage Offset Correction: v_off_ini = 2755.487 uV, v_off_fin = 2758.309 uV 15:22:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.504 uVs 15:22:48 Integrated Voltage Measurement... 15:22:57 Voltage Offset Correction: v_off_ini = 2759.272 uV, v_off_fin = 2755.374 uV 15:22:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.567 uVs 15:22:57 Integrated Voltage Measurement... 15:23:06 Voltage Offset Correction: v_off_ini = 2740.449 uV, v_off_fin = 2731.712 uV 15:23:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.180 uVs 15:23:10 I1Y Average and RMS of Measurements VT = -217.553 +- 4.806 uVs I1Y = -43.511 +- 0.961 uTm 15:23:12 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:23:15 Integrated Voltage Measurement... 15:23:24 Voltage Offset Correction: v_off_ini = 2747.324 uV, v_off_fin = 2738.324 uV 15:23:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.937 uVs 15:23:24 Integrated Voltage Measurement... 15:23:33 Voltage Offset Correction: v_off_ini = 2746.662 uV, v_off_fin = 2749.279 uV 15:23:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.504 uVs 15:23:33 Integrated Voltage Measurement... 15:23:42 Voltage Offset Correction: v_off_ini = 2760.514 uV, v_off_fin = 2733.924 uV 15:23:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.422 uVs 15:23:42 Integrated Voltage Measurement... 15:23:51 Voltage Offset Correction: v_off_ini = 2742.722 uV, v_off_fin = 2751.783 uV 15:23:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 90.160 uVs 15:23:51 Integrated Voltage Measurement... 15:24:00 Voltage Offset Correction: v_off_ini = 2729.191 uV, v_off_fin = 2723.535 uV 15:24:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.039 uVs 15:24:00 Integrated Voltage Measurement... 15:24:09 Voltage Offset Correction: v_off_ini = 2743.770 uV, v_off_fin = 2753.521 uV 15:24:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.776 uVs 15:24:12 I2X Average and RMS of Measurements VT = -98.806 +- 7.709 uVs I2X = 9.090 +- 0.709 uTm^2 15:24:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:24:17 Integrated Voltage Measurement... 15:24:26 Voltage Offset Correction: v_off_ini = 2734.084 uV, v_off_fin = 2746.637 uV 15:24:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.247 uVs 15:24:26 Integrated Voltage Measurement... 15:24:35 Voltage Offset Correction: v_off_ini = 2745.321 uV, v_off_fin = 2750.476 uV 15:24:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.965 uVs 15:24:35 Integrated Voltage Measurement... 15:24:44 Voltage Offset Correction: v_off_ini = 2740.984 uV, v_off_fin = 2736.594 uV 15:24:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.643 uVs 15:24:44 Integrated Voltage Measurement... 15:24:53 Voltage Offset Correction: v_off_ini = 2760.386 uV, v_off_fin = 2768.119 uV 15:24:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.533 uVs 15:24:53 Integrated Voltage Measurement... 15:25:02 Voltage Offset Correction: v_off_ini = 2778.209 uV, v_off_fin = 2777.323 uV 15:25:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.624 uVs 15:25:02 Integrated Voltage Measurement... 15:25:11 Voltage Offset Correction: v_off_ini = 2756.751 uV, v_off_fin = 2760.282 uV 15:25:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.821 uVs 15:25:13 I2Y Average and RMS of Measurements VT = -207.805 +- 4.240 uVs I2Y = -19.118 +- 0.390 uTm^2 15:25:17 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:25:21 Integrated Voltage Measurement... 15:25:30 Voltage Offset Correction: v_off_ini = 2758.915 uV, v_off_fin = 2750.868 uV 15:25:30 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -150.657 uVs 15:25:30 Integrated Voltage Measurement... 15:25:39 Voltage Offset Correction: v_off_ini = 2749.239 uV, v_off_fin = 2768.771 uV 15:25:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 134.652 uVs 15:25:39 Integrated Voltage Measurement... 15:25:48 Voltage Offset Correction: v_off_ini = 2774.410 uV, v_off_fin = 2766.122 uV 15:25:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -122.828 uVs 15:25:48 Integrated Voltage Measurement... 15:25:57 Voltage Offset Correction: v_off_ini = 2782.035 uV, v_off_fin = 2775.934 uV 15:25:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.003 uVs 15:25:58 Integrated Voltage Measurement... 15:26:06 Voltage Offset Correction: v_off_ini = 2788.697 uV, v_off_fin = 2762.035 uV 15:26:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.114 uVs 15:26:07 Integrated Voltage Measurement... 15:26:15 Voltage Offset Correction: v_off_ini = 2780.562 uV, v_off_fin = 2763.734 uV 15:26:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 108.119 uVs 15:26:20 I1X Average and RMS of Measurements VT = -131.896 +- 9.004 uVs I1X = 26.380 +- 1.802 uTm 15:26:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:26:26 Integrated Voltage Measurement... 15:26:35 Voltage Offset Correction: v_off_ini = 2794.422 uV, v_off_fin = 2782.164 uV 15:26:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.892 uVs 15:26:35 Integrated Voltage Measurement... 15:26:44 Voltage Offset Correction: v_off_ini = 2771.724 uV, v_off_fin = 2785.944 uV 15:26:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.292 uVs 15:26:44 Integrated Voltage Measurement... 15:26:53 Voltage Offset Correction: v_off_ini = 2779.228 uV, v_off_fin = 2770.682 uV 15:26:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.173 uVs 15:26:53 Integrated Voltage Measurement... 15:27:02 Voltage Offset Correction: v_off_ini = 2763.510 uV, v_off_fin = 2780.770 uV 15:27:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.416 uVs 15:27:02 Integrated Voltage Measurement... 15:27:11 Voltage Offset Correction: v_off_ini = 2761.599 uV, v_off_fin = 2744.198 uV 15:27:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.991 uVs 15:27:11 Integrated Voltage Measurement... 15:27:20 Voltage Offset Correction: v_off_ini = 2742.335 uV, v_off_fin = 2754.312 uV 15:27:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.925 uVs 15:27:25 I1Y Average and RMS of Measurements VT = -222.948 +- 5.476 uVs I1Y = -44.590 +- 1.095 uTm 15:27:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:27:30 Integrated Voltage Measurement... 15:27:39 Voltage Offset Correction: v_off_ini = 2712.486 uV, v_off_fin = 2718.355 uV 15:27:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.909 uVs 15:27:39 Integrated Voltage Measurement... 15:27:48 Voltage Offset Correction: v_off_ini = 2711.396 uV, v_off_fin = 2740.874 uV 15:27:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.093 uVs 15:27:48 Integrated Voltage Measurement... 15:27:57 Voltage Offset Correction: v_off_ini = 2721.930 uV, v_off_fin = 2689.222 uV 15:27:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.352 uVs 15:27:57 Integrated Voltage Measurement... 15:28:06 Voltage Offset Correction: v_off_ini = 2737.366 uV, v_off_fin = 2714.691 uV 15:28:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.578 uVs 15:28:06 Integrated Voltage Measurement... 15:28:15 Voltage Offset Correction: v_off_ini = 2725.722 uV, v_off_fin = 2727.574 uV 15:28:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.701 uVs 15:28:15 Integrated Voltage Measurement... 15:28:24 Voltage Offset Correction: v_off_ini = 2734.427 uV, v_off_fin = 2722.477 uV 15:28:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.228 uVs 15:28:26 I2X Average and RMS of Measurements VT = -93.977 +- 9.404 uVs I2X = 8.646 +- 0.865 uTm^2 15:28:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:28:31 Integrated Voltage Measurement... 15:28:40 Voltage Offset Correction: v_off_ini = 2749.550 uV, v_off_fin = 2750.002 uV 15:28:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.668 uVs 15:28:40 Integrated Voltage Measurement... 15:28:49 Voltage Offset Correction: v_off_ini = 2726.864 uV, v_off_fin = 2727.605 uV 15:28:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.774 uVs 15:28:49 Integrated Voltage Measurement... 15:28:58 Voltage Offset Correction: v_off_ini = 2743.312 uV, v_off_fin = 2740.190 uV 15:28:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.593 uVs 15:28:58 Integrated Voltage Measurement... 15:29:07 Voltage Offset Correction: v_off_ini = 2735.271 uV, v_off_fin = 2748.112 uV 15:29:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.934 uVs 15:29:07 Integrated Voltage Measurement... 15:29:16 Voltage Offset Correction: v_off_ini = 2756.897 uV, v_off_fin = 2736.545 uV 15:29:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.528 uVs 15:29:16 Integrated Voltage Measurement... 15:29:25 Voltage Offset Correction: v_off_ini = 2724.609 uV, v_off_fin = 2714.163 uV 15:29:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.149 uVs 15:29:28 I2Y Average and RMS of Measurements VT = -207.441 +- 2.989 uVs I2Y = -19.085 +- 0.275 uTm^2 15:29:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:29:36 Integrated Voltage Measurement... 15:29:45 Voltage Offset Correction: v_off_ini = 2755.049 uV, v_off_fin = 2717.781 uV 15:29:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -163.233 uVs 15:29:45 Integrated Voltage Measurement... 15:29:54 Voltage Offset Correction: v_off_ini = 2731.046 uV, v_off_fin = 2744.291 uV 15:29:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.863 uVs 15:29:54 Integrated Voltage Measurement... 15:30:03 Voltage Offset Correction: v_off_ini = 2724.439 uV, v_off_fin = 2743.159 uV 15:30:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.437 uVs 15:30:03 Integrated Voltage Measurement... 15:30:12 Voltage Offset Correction: v_off_ini = 2747.360 uV, v_off_fin = 2741.308 uV 15:30:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.162 uVs 15:30:12 Integrated Voltage Measurement... 15:30:21 Voltage Offset Correction: v_off_ini = 2735.525 uV, v_off_fin = 2742.330 uV 15:30:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.141 uVs 15:30:21 Integrated Voltage Measurement... 15:30:30 Voltage Offset Correction: v_off_ini = 2725.065 uV, v_off_fin = 2738.477 uV 15:30:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.355 uVs 15:30:34 I1X Average and RMS of Measurements VT = -135.532 +- 9.460 uVs I1X = 27.108 +- 1.893 uTm 15:30:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:30:41 Integrated Voltage Measurement... 15:30:50 Voltage Offset Correction: v_off_ini = 2702.584 uV, v_off_fin = 2718.897 uV 15:30:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.056 uVs 15:30:50 Integrated Voltage Measurement... 15:30:59 Voltage Offset Correction: v_off_ini = 2728.861 uV, v_off_fin = 2745.064 uV 15:30:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 229.661 uVs 15:30:59 Integrated Voltage Measurement... 15:31:08 Voltage Offset Correction: v_off_ini = 2754.776 uV, v_off_fin = 2720.643 uV 15:31:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.775 uVs 15:31:08 Integrated Voltage Measurement... 15:31:17 Voltage Offset Correction: v_off_ini = 2743.854 uV, v_off_fin = 2745.210 uV 15:31:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.394 uVs 15:31:17 Integrated Voltage Measurement... 15:31:26 Voltage Offset Correction: v_off_ini = 2730.618 uV, v_off_fin = 2729.705 uV 15:31:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.243 uVs 15:31:26 Integrated Voltage Measurement... 15:31:35 Voltage Offset Correction: v_off_ini = 2749.824 uV, v_off_fin = 2748.163 uV 15:31:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 226.284 uVs 15:31:39 I1Y Average and RMS of Measurements VT = -219.069 +- 3.528 uVs I1Y = -43.810 +- 0.706 uTm 15:31:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:31:44 Integrated Voltage Measurement... 15:31:53 Voltage Offset Correction: v_off_ini = 2727.534 uV, v_off_fin = 2734.749 uV 15:31:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -61.556 uVs 15:31:53 Integrated Voltage Measurement... 15:32:02 Voltage Offset Correction: v_off_ini = 2717.633 uV, v_off_fin = 2752.004 uV 15:32:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 79.874 uVs 15:32:02 Integrated Voltage Measurement... 15:32:11 Voltage Offset Correction: v_off_ini = 2737.023 uV, v_off_fin = 2730.032 uV 15:32:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.348 uVs 15:32:11 Integrated Voltage Measurement... 15:32:20 Voltage Offset Correction: v_off_ini = 2734.591 uV, v_off_fin = 2756.810 uV 15:32:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 74.081 uVs 15:32:20 Integrated Voltage Measurement... 15:32:29 Voltage Offset Correction: v_off_ini = 2764.801 uV, v_off_fin = 2745.478 uV 15:32:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.132 uVs 15:32:29 Integrated Voltage Measurement... 15:32:38 Voltage Offset Correction: v_off_ini = 2756.952 uV, v_off_fin = 2761.369 uV 15:32:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.184 uVs 15:32:41 I2X Average and RMS of Measurements VT = -88.029 +- 12.567 uVs I2X = 8.099 +- 1.156 uTm^2 15:32:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:32:46 Integrated Voltage Measurement... 15:32:55 Voltage Offset Correction: v_off_ini = 2784.783 uV, v_off_fin = 2783.446 uV 15:32:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.242 uVs 15:32:55 Integrated Voltage Measurement... 15:33:04 Voltage Offset Correction: v_off_ini = 2742.334 uV, v_off_fin = 2762.828 uV 15:33:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.698 uVs 15:33:04 Integrated Voltage Measurement... 15:33:13 Voltage Offset Correction: v_off_ini = 2770.355 uV, v_off_fin = 2782.521 uV 15:33:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -183.489 uVs 15:33:13 Integrated Voltage Measurement... 15:33:22 Voltage Offset Correction: v_off_ini = 2768.193 uV, v_off_fin = 2765.098 uV 15:33:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.780 uVs 15:33:22 Integrated Voltage Measurement... 15:33:31 Voltage Offset Correction: v_off_ini = 2753.531 uV, v_off_fin = 2738.712 uV 15:33:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -205.121 uVs 15:33:31 Integrated Voltage Measurement... 15:33:40 Voltage Offset Correction: v_off_ini = 2724.112 uV, v_off_fin = 2754.219 uV 15:33:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 217.774 uVs 15:33:42 I2Y Average and RMS of Measurements VT = -200.684 +- 9.126 uVs I2Y = -18.463 +- 0.840 uTm^2 15:33:46 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:33:51 Integrated Voltage Measurement... 15:34:00 Voltage Offset Correction: v_off_ini = 2768.515 uV, v_off_fin = 2766.774 uV 15:34:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -144.192 uVs 15:34:00 Integrated Voltage Measurement... 15:34:09 Voltage Offset Correction: v_off_ini = 2784.826 uV, v_off_fin = 2785.201 uV 15:34:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.484 uVs 15:34:09 Integrated Voltage Measurement... 15:34:18 Voltage Offset Correction: v_off_ini = 2787.072 uV, v_off_fin = 2779.247 uV 15:34:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -150.034 uVs 15:34:18 Integrated Voltage Measurement... 15:34:27 Voltage Offset Correction: v_off_ini = 2768.587 uV, v_off_fin = 2786.944 uV 15:34:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 124.553 uVs 15:34:27 Integrated Voltage Measurement... 15:34:36 Voltage Offset Correction: v_off_ini = 2771.669 uV, v_off_fin = 2762.621 uV 15:34:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.449 uVs 15:34:36 Integrated Voltage Measurement... 15:34:45 Voltage Offset Correction: v_off_ini = 2778.278 uV, v_off_fin = 2758.926 uV 15:34:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 106.067 uVs 15:34:49 I1X Average and RMS of Measurements VT = -131.463 +- 10.472 uVs I1X = 26.294 +- 2.095 uTm 15:34:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:34:56 Integrated Voltage Measurement... 15:35:05 Voltage Offset Correction: v_off_ini = 2755.629 uV, v_off_fin = 2759.540 uV 15:35:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.252 uVs 15:35:05 Integrated Voltage Measurement... 15:35:14 Voltage Offset Correction: v_off_ini = 2772.704 uV, v_off_fin = 2776.755 uV 15:35:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.998 uVs 15:35:14 Integrated Voltage Measurement... 15:35:23 Voltage Offset Correction: v_off_ini = 2765.505 uV, v_off_fin = 2749.542 uV 15:35:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.688 uVs 15:35:23 Integrated Voltage Measurement... 15:35:32 Voltage Offset Correction: v_off_ini = 2775.509 uV, v_off_fin = 2785.188 uV 15:35:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.931 uVs 15:35:32 Integrated Voltage Measurement... 15:35:41 Voltage Offset Correction: v_off_ini = 2766.546 uV, v_off_fin = 2746.642 uV 15:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -213.599 uVs 15:35:41 Integrated Voltage Measurement... 15:35:50 Voltage Offset Correction: v_off_ini = 2763.158 uV, v_off_fin = 2774.900 uV 15:35:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 216.026 uVs 15:35:54 I1Y Average and RMS of Measurements VT = -212.249 +- 2.118 uVs I1Y = -42.448 +- 0.422 uTm 15:35:56 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:35:59 Integrated Voltage Measurement... 15:36:08 Voltage Offset Correction: v_off_ini = 2755.463 uV, v_off_fin = 2745.241 uV 15:36:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.925 uVs 15:36:08 Integrated Voltage Measurement... 15:36:17 Voltage Offset Correction: v_off_ini = 2739.561 uV, v_off_fin = 2739.472 uV 15:36:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 78.207 uVs 15:36:17 Integrated Voltage Measurement... 15:36:26 Voltage Offset Correction: v_off_ini = 2764.414 uV, v_off_fin = 2739.076 uV 15:36:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.246 uVs 15:36:26 Integrated Voltage Measurement... 15:36:35 Voltage Offset Correction: v_off_ini = 2747.629 uV, v_off_fin = 2738.988 uV 15:36:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.835 uVs 15:36:35 Integrated Voltage Measurement... 15:36:44 Voltage Offset Correction: v_off_ini = 2739.267 uV, v_off_fin = 2716.971 uV 15:36:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.833 uVs 15:36:44 Integrated Voltage Measurement... 15:36:53 Voltage Offset Correction: v_off_ini = 2741.062 uV, v_off_fin = 2746.663 uV 15:36:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.835 uVs 15:36:55 I2X Average and RMS of Measurements VT = -79.814 +- 8.494 uVs I2X = 7.343 +- 0.781 uTm^2 15:36:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:37:01 Integrated Voltage Measurement... 15:37:10 Voltage Offset Correction: v_off_ini = 2732.090 uV, v_off_fin = 2750.902 uV 15:37:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -196.687 uVs 15:37:10 Integrated Voltage Measurement... 15:37:19 Voltage Offset Correction: v_off_ini = 2736.886 uV, v_off_fin = 2740.529 uV 15:37:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.688 uVs 15:37:19 Integrated Voltage Measurement... 15:37:28 Voltage Offset Correction: v_off_ini = 2725.520 uV, v_off_fin = 2730.823 uV 15:37:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.426 uVs 15:37:28 Integrated Voltage Measurement... 15:37:37 Voltage Offset Correction: v_off_ini = 2724.411 uV, v_off_fin = 2727.474 uV 15:37:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.658 uVs 15:37:37 Integrated Voltage Measurement... 15:37:46 Voltage Offset Correction: v_off_ini = 2730.496 uV, v_off_fin = 2743.005 uV 15:37:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.202 uVs 15:37:46 Integrated Voltage Measurement... 15:37:55 Voltage Offset Correction: v_off_ini = 2739.364 uV, v_off_fin = 2734.873 uV 15:37:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.457 uVs 15:37:57 I2Y Average and RMS of Measurements VT = -197.853 +- 1.587 uVs I2Y = -18.203 +- 0.146 uTm^2 15:38:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:38:18 Integrated Voltage Measurement... 15:38:27 Voltage Offset Correction: v_off_ini = 2744.604 uV, v_off_fin = 2729.882 uV 15:38:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -145.356 uVs 15:38:27 Integrated Voltage Measurement... 15:38:36 Voltage Offset Correction: v_off_ini = 2742.347 uV, v_off_fin = 2744.819 uV 15:38:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.438 uVs 15:38:36 Integrated Voltage Measurement... 15:38:45 Voltage Offset Correction: v_off_ini = 2750.133 uV, v_off_fin = 2749.441 uV 15:38:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -118.055 uVs 15:38:45 Integrated Voltage Measurement... 15:38:54 Voltage Offset Correction: v_off_ini = 2786.860 uV, v_off_fin = 2776.544 uV 15:38:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 140.130 uVs 15:38:54 Integrated Voltage Measurement... 15:39:03 Voltage Offset Correction: v_off_ini = 2768.222 uV, v_off_fin = 2751.158 uV 15:39:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.727 uVs 15:39:03 Integrated Voltage Measurement... 15:39:12 Voltage Offset Correction: v_off_ini = 2746.529 uV, v_off_fin = 2750.750 uV 15:39:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.686 uVs 15:39:17 I1X Average and RMS of Measurements VT = -144.399 +- 10.879 uVs I1X = 28.880 +- 2.176 uTm 15:39:19 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:39:23 Integrated Voltage Measurement... 15:39:32 Voltage Offset Correction: v_off_ini = 2724.532 uV, v_off_fin = 2714.401 uV 15:39:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.663 uVs 15:39:32 Integrated Voltage Measurement... 15:39:41 Voltage Offset Correction: v_off_ini = 2733.893 uV, v_off_fin = 2757.969 uV 15:39:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.123 uVs 15:39:41 Integrated Voltage Measurement... 15:39:50 Voltage Offset Correction: v_off_ini = 2741.652 uV, v_off_fin = 2741.453 uV 15:39:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.397 uVs 15:39:50 Integrated Voltage Measurement... 15:39:59 Voltage Offset Correction: v_off_ini = 2732.101 uV, v_off_fin = 2757.547 uV 15:39:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 191.507 uVs 15:39:59 Integrated Voltage Measurement... 15:40:08 Voltage Offset Correction: v_off_ini = 2754.512 uV, v_off_fin = 2754.307 uV 15:40:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.357 uVs 15:40:08 Integrated Voltage Measurement... 15:40:17 Voltage Offset Correction: v_off_ini = 2771.257 uV, v_off_fin = 2776.456 uV 15:40:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.520 uVs 15:40:21 I1Y Average and RMS of Measurements VT = -202.428 +- 8.372 uVs I1Y = -40.486 +- 1.674 uTm 15:40:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:40:29 Integrated Voltage Measurement... 15:40:38 Voltage Offset Correction: v_off_ini = 2741.510 uV, v_off_fin = 2754.037 uV 15:40:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.974 uVs 15:40:38 Integrated Voltage Measurement... 15:40:47 Voltage Offset Correction: v_off_ini = 2771.618 uV, v_off_fin = 2774.871 uV 15:40:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 136.649 uVs 15:40:47 Integrated Voltage Measurement... 15:40:56 Voltage Offset Correction: v_off_ini = 2758.081 uV, v_off_fin = 2768.709 uV 15:40:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.332 uVs 15:40:56 Integrated Voltage Measurement... 15:41:05 Voltage Offset Correction: v_off_ini = 2773.470 uV, v_off_fin = 2786.338 uV 15:41:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.680 uVs 15:41:05 Integrated Voltage Measurement... 15:41:14 Voltage Offset Correction: v_off_ini = 2780.486 uV, v_off_fin = 2748.795 uV 15:41:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.515 uVs 15:41:14 Integrated Voltage Measurement... 15:41:23 Voltage Offset Correction: v_off_ini = 2757.608 uV, v_off_fin = 2766.186 uV 15:41:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.529 uVs 15:41:26 I2X Average and RMS of Measurements VT = -116.446 +- 12.168 uVs I2X = 10.713 +- 1.119 uTm^2 15:41:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 15:41:33 Integrated Voltage Measurement... 15:41:42 Voltage Offset Correction: v_off_ini = 2766.843 uV, v_off_fin = 2760.220 uV 15:41:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.947 uVs 15:41:42 Integrated Voltage Measurement... 15:41:51 Voltage Offset Correction: v_off_ini = 2773.387 uV, v_off_fin = 2799.181 uV 15:41:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 156.554 uVs 15:41:51 Integrated Voltage Measurement... 15:42:00 Voltage Offset Correction: v_off_ini = 2759.978 uV, v_off_fin = 2786.236 uV 15:42:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.897 uVs 15:42:00 Integrated Voltage Measurement... 15:42:09 Voltage Offset Correction: v_off_ini = 2787.705 uV, v_off_fin = 2786.366 uV 15:42:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.621 uVs 15:42:09 Integrated Voltage Measurement... 15:42:18 Voltage Offset Correction: v_off_ini = 2781.004 uV, v_off_fin = 2770.300 uV 15:42:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.243 uVs 15:42:19 Integrated Voltage Measurement... 15:42:27 Voltage Offset Correction: v_off_ini = 2773.154 uV, v_off_fin = 2772.470 uV 15:42:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.579 uVs 15:42:30 I2Y Average and RMS of Measurements VT = -188.974 +- 19.023 uVs I2Y = -17.386 +- 1.750 uTm^2 15:42:35 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:42:39 Integrated Voltage Measurement... 15:42:48 Voltage Offset Correction: v_off_ini = 2789.171 uV, v_off_fin = 2775.440 uV 15:42:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -139.091 uVs 15:42:48 Integrated Voltage Measurement... 15:42:57 Voltage Offset Correction: v_off_ini = 2794.631 uV, v_off_fin = 2795.799 uV 15:42:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.340 uVs 15:42:57 Integrated Voltage Measurement... 15:43:06 Voltage Offset Correction: v_off_ini = 2788.331 uV, v_off_fin = 2792.452 uV 15:43:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -166.854 uVs 15:43:06 Integrated Voltage Measurement... 15:43:15 Voltage Offset Correction: v_off_ini = 2791.618 uV, v_off_fin = 2772.447 uV 15:43:15 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.051 uVs 15:43:15 Integrated Voltage Measurement... 15:43:24 Voltage Offset Correction: v_off_ini = 2773.084 uV, v_off_fin = 2767.552 uV 15:43:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.791 uVs 15:43:24 Integrated Voltage Measurement... 15:43:33 Voltage Offset Correction: v_off_ini = 2770.773 uV, v_off_fin = 2765.898 uV 15:43:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.521 uVs 15:43:37 I1X Average and RMS of Measurements VT = -140.941 +- 7.083 uVs I1X = 28.190 +- 1.417 uTm 15:43:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:43:44 Integrated Voltage Measurement... 15:43:53 Voltage Offset Correction: v_off_ini = 2785.291 uV, v_off_fin = 2779.624 uV 15:43:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.955 uVs 15:43:53 Integrated Voltage Measurement... 15:44:02 Voltage Offset Correction: v_off_ini = 2784.028 uV, v_off_fin = 2778.905 uV 15:44:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.521 uVs 15:44:02 Integrated Voltage Measurement... 15:44:11 Voltage Offset Correction: v_off_ini = 2777.622 uV, v_off_fin = 2772.226 uV 15:44:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.143 uVs 15:44:11 Integrated Voltage Measurement... 15:44:20 Voltage Offset Correction: v_off_ini = 2760.099 uV, v_off_fin = 2756.095 uV 15:44:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.323 uVs 15:44:20 Integrated Voltage Measurement... 15:44:29 Voltage Offset Correction: v_off_ini = 2747.946 uV, v_off_fin = 2751.095 uV 15:44:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.848 uVs 15:44:29 Integrated Voltage Measurement... 15:44:38 Voltage Offset Correction: v_off_ini = 2760.296 uV, v_off_fin = 2760.078 uV 15:44:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.429 uVs 15:44:42 I1Y Average and RMS of Measurements VT = -198.536 +- 1.911 uVs I1Y = -39.707 +- 0.382 uTm 15:44:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:44:50 Integrated Voltage Measurement... 15:44:59 Voltage Offset Correction: v_off_ini = 2722.936 uV, v_off_fin = 2721.765 uV 15:44:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -97.784 uVs 15:44:59 Integrated Voltage Measurement... 15:45:08 Voltage Offset Correction: v_off_ini = 2715.716 uV, v_off_fin = 2742.402 uV 15:45:08 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 113.756 uVs 15:45:08 Integrated Voltage Measurement... 15:45:17 Voltage Offset Correction: v_off_ini = 2747.228 uV, v_off_fin = 2734.715 uV 15:45:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.144 uVs 15:45:17 Integrated Voltage Measurement... 15:45:26 Voltage Offset Correction: v_off_ini = 2712.118 uV, v_off_fin = 2737.867 uV 15:45:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 122.425 uVs 15:45:26 Integrated Voltage Measurement... 15:45:35 Voltage Offset Correction: v_off_ini = 2744.009 uV, v_off_fin = 2717.356 uV 15:45:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -100.290 uVs 15:45:35 Integrated Voltage Measurement... 15:45:44 Voltage Offset Correction: v_off_ini = 2736.669 uV, v_off_fin = 2739.370 uV 15:45:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 141.594 uVs 15:45:46 I2X Average and RMS of Measurements VT = -115.165 +- 6.702 uVs I2X = 10.595 +- 0.616 uTm^2 15:45:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 15:45:54 Integrated Voltage Measurement... 15:46:03 Voltage Offset Correction: v_off_ini = 2726.006 uV, v_off_fin = 2734.158 uV 15:46:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -174.037 uVs 15:46:03 Integrated Voltage Measurement... 15:46:12 Voltage Offset Correction: v_off_ini = 2722.585 uV, v_off_fin = 2717.471 uV 15:46:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.197 uVs 15:46:12 Integrated Voltage Measurement... 15:46:21 Voltage Offset Correction: v_off_ini = 2710.304 uV, v_off_fin = 2709.372 uV 15:46:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -198.935 uVs 15:46:21 Integrated Voltage Measurement... 15:46:30 Voltage Offset Correction: v_off_ini = 2713.119 uV, v_off_fin = 2736.710 uV 15:46:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.342 uVs 15:46:30 Integrated Voltage Measurement... 15:46:39 Voltage Offset Correction: v_off_ini = 2732.280 uV, v_off_fin = 2748.381 uV 15:46:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.962 uVs 15:46:39 Integrated Voltage Measurement... 15:46:48 Voltage Offset Correction: v_off_ini = 2727.906 uV, v_off_fin = 2736.750 uV 15:46:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 196.403 uVs 15:46:50 I2Y Average and RMS of Measurements VT = -190.313 +- 5.456 uVs I2Y = -17.509 +- 0.502 uTm^2 15:46:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:46:59 Integrated Voltage Measurement... 15:47:08 Voltage Offset Correction: v_off_ini = 2742.934 uV, v_off_fin = 2729.154 uV 15:47:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.977 uVs 15:47:08 Integrated Voltage Measurement... 15:47:17 Voltage Offset Correction: v_off_ini = 2726.874 uV, v_off_fin = 2728.328 uV 15:47:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.737 uVs 15:47:17 Integrated Voltage Measurement... 15:47:26 Voltage Offset Correction: v_off_ini = 2729.451 uV, v_off_fin = 2738.983 uV 15:47:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.742 uVs 15:47:26 Integrated Voltage Measurement... 15:47:35 Voltage Offset Correction: v_off_ini = 2738.622 uV, v_off_fin = 2742.112 uV 15:47:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.853 uVs 15:47:35 Integrated Voltage Measurement... 15:47:44 Voltage Offset Correction: v_off_ini = 2730.458 uV, v_off_fin = 2736.513 uV 15:47:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -133.314 uVs 15:47:44 Integrated Voltage Measurement... 15:47:53 Voltage Offset Correction: v_off_ini = 2719.911 uV, v_off_fin = 2715.844 uV 15:47:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 144.748 uVs 15:47:57 I1X Average and RMS of Measurements VT = -139.062 +- 5.127 uVs I1X = 27.812 +- 1.025 uTm 15:48:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:48:04 Integrated Voltage Measurement... 15:48:13 Voltage Offset Correction: v_off_ini = 2735.817 uV, v_off_fin = 2710.265 uV 15:48:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.676 uVs 15:48:13 Integrated Voltage Measurement... 15:48:22 Voltage Offset Correction: v_off_ini = 2720.978 uV, v_off_fin = 2741.667 uV 15:48:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.243 uVs 15:48:22 Integrated Voltage Measurement... 15:48:31 Voltage Offset Correction: v_off_ini = 2743.106 uV, v_off_fin = 2752.051 uV 15:48:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.424 uVs 15:48:31 Integrated Voltage Measurement... 15:48:40 Voltage Offset Correction: v_off_ini = 2722.037 uV, v_off_fin = 2734.904 uV 15:48:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.570 uVs 15:48:40 Integrated Voltage Measurement... 15:48:49 Voltage Offset Correction: v_off_ini = 2723.825 uV, v_off_fin = 2730.165 uV 15:48:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.497 uVs 15:48:49 Integrated Voltage Measurement... 15:48:58 Voltage Offset Correction: v_off_ini = 2727.903 uV, v_off_fin = 2752.941 uV 15:48:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.812 uVs 15:49:02 I1Y Average and RMS of Measurements VT = -209.204 +- 4.988 uVs I1Y = -41.841 +- 0.998 uTm 15:49:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:49:10 Integrated Voltage Measurement... 15:49:19 Voltage Offset Correction: v_off_ini = 2732.872 uV, v_off_fin = 2729.020 uV 15:49:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.994 uVs 15:49:19 Integrated Voltage Measurement... 15:49:28 Voltage Offset Correction: v_off_ini = 2746.899 uV, v_off_fin = 2738.835 uV 15:49:28 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.160 uVs 15:49:28 Integrated Voltage Measurement... 15:49:37 Voltage Offset Correction: v_off_ini = 2731.733 uV, v_off_fin = 2707.842 uV 15:49:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -101.467 uVs 15:49:37 Integrated Voltage Measurement... 15:49:46 Voltage Offset Correction: v_off_ini = 2727.849 uV, v_off_fin = 2734.019 uV 15:49:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 80.017 uVs 15:49:46 Integrated Voltage Measurement... 15:49:55 Voltage Offset Correction: v_off_ini = 2729.554 uV, v_off_fin = 2705.352 uV 15:49:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -117.526 uVs 15:49:55 Integrated Voltage Measurement... 15:50:04 Voltage Offset Correction: v_off_ini = 2709.809 uV, v_off_fin = 2706.837 uV 15:50:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.927 uVs 15:50:07 I2X Average and RMS of Measurements VT = -101.682 +- 9.904 uVs I2X = 9.355 +- 0.911 uTm^2 15:50:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:50:14 Integrated Voltage Measurement... 15:50:23 Voltage Offset Correction: v_off_ini = 2715.309 uV, v_off_fin = 2709.363 uV 15:50:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.961 uVs 15:50:23 Integrated Voltage Measurement... 15:50:32 Voltage Offset Correction: v_off_ini = 2707.113 uV, v_off_fin = 2710.100 uV 15:50:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 209.475 uVs 15:50:32 Integrated Voltage Measurement... 15:50:41 Voltage Offset Correction: v_off_ini = 2691.785 uV, v_off_fin = 2702.195 uV 15:50:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.410 uVs 15:50:41 Integrated Voltage Measurement... 15:50:50 Voltage Offset Correction: v_off_ini = 2696.295 uV, v_off_fin = 2699.267 uV 15:50:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.111 uVs 15:50:50 Integrated Voltage Measurement... 15:50:59 Voltage Offset Correction: v_off_ini = 2697.394 uV, v_off_fin = 2691.246 uV 15:50:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.994 uVs 15:50:59 Integrated Voltage Measurement... 15:51:08 Voltage Offset Correction: v_off_ini = 2703.311 uV, v_off_fin = 2701.903 uV 15:51:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.854 uVs 15:51:11 I2Y Average and RMS of Measurements VT = -191.467 +- 7.340 uVs I2Y = -17.615 +- 0.675 uTm^2 15:51:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:51:20 Integrated Voltage Measurement... 15:51:29 Voltage Offset Correction: v_off_ini = 2677.234 uV, v_off_fin = 2674.080 uV 15:51:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.393 uVs 15:51:29 Integrated Voltage Measurement... 15:51:38 Voltage Offset Correction: v_off_ini = 2680.202 uV, v_off_fin = 2696.627 uV 15:51:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 142.184 uVs 15:51:38 Integrated Voltage Measurement... 15:51:47 Voltage Offset Correction: v_off_ini = 2714.346 uV, v_off_fin = 2684.728 uV 15:51:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -152.481 uVs 15:51:47 Integrated Voltage Measurement... 15:51:56 Voltage Offset Correction: v_off_ini = 2665.619 uV, v_off_fin = 2678.054 uV 15:51:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 133.932 uVs 15:51:56 Integrated Voltage Measurement... 15:52:05 Voltage Offset Correction: v_off_ini = 2674.910 uV, v_off_fin = 2690.719 uV 15:52:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -148.493 uVs 15:52:05 Integrated Voltage Measurement... 15:52:14 Voltage Offset Correction: v_off_ini = 2701.342 uV, v_off_fin = 2701.915 uV 15:52:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 122.244 uVs 15:52:18 I1X Average and RMS of Measurements VT = -139.288 +- 3.200 uVs I1X = 27.859 +- 0.641 uTm 15:52:20 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:52:25 Integrated Voltage Measurement... 15:52:34 Voltage Offset Correction: v_off_ini = 2710.105 uV, v_off_fin = 2689.885 uV 15:52:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.237 uVs 15:52:34 Integrated Voltage Measurement... 15:52:43 Voltage Offset Correction: v_off_ini = 2715.835 uV, v_off_fin = 2701.046 uV 15:52:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.306 uVs 15:52:43 Integrated Voltage Measurement... 15:52:52 Voltage Offset Correction: v_off_ini = 2714.340 uV, v_off_fin = 2701.668 uV 15:52:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.948 uVs 15:52:52 Integrated Voltage Measurement... 15:53:01 Voltage Offset Correction: v_off_ini = 2732.187 uV, v_off_fin = 2729.087 uV 15:53:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.856 uVs 15:53:01 Integrated Voltage Measurement... 15:53:10 Voltage Offset Correction: v_off_ini = 2743.775 uV, v_off_fin = 2762.098 uV 15:53:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.322 uVs 15:53:10 Integrated Voltage Measurement... 15:53:19 Voltage Offset Correction: v_off_ini = 2718.106 uV, v_off_fin = 2767.925 uV 15:53:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.586 uVs 15:53:23 I1Y Average and RMS of Measurements VT = -213.709 +- 6.218 uVs I1Y = -42.742 +- 1.244 uTm 15:53:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:53:30 Integrated Voltage Measurement... 15:53:39 Voltage Offset Correction: v_off_ini = 2738.662 uV, v_off_fin = 2734.489 uV 15:53:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -89.855 uVs 15:53:39 Integrated Voltage Measurement... 15:53:48 Voltage Offset Correction: v_off_ini = 2749.095 uV, v_off_fin = 2742.682 uV 15:53:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.802 uVs 15:53:48 Integrated Voltage Measurement... 15:53:57 Voltage Offset Correction: v_off_ini = 2735.080 uV, v_off_fin = 2726.225 uV 15:53:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.135 uVs 15:53:58 Integrated Voltage Measurement... 15:54:06 Voltage Offset Correction: v_off_ini = 2705.104 uV, v_off_fin = 2736.040 uV 15:54:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 121.307 uVs 15:54:07 Integrated Voltage Measurement... 15:54:16 Voltage Offset Correction: v_off_ini = 2715.863 uV, v_off_fin = 2714.283 uV 15:54:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.475 uVs 15:54:16 Integrated Voltage Measurement... 15:54:25 Voltage Offset Correction: v_off_ini = 2716.068 uV, v_off_fin = 2706.957 uV 15:54:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.142 uVs 15:54:27 I2X Average and RMS of Measurements VT = -100.286 +- 14.156 uVs I2X = 9.226 +- 1.302 uTm^2 15:54:32 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 15:54:35 Integrated Voltage Measurement... 15:54:44 Voltage Offset Correction: v_off_ini = 2693.328 uV, v_off_fin = 2690.359 uV 15:54:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.649 uVs 15:54:44 Integrated Voltage Measurement... 15:54:53 Voltage Offset Correction: v_off_ini = 2686.950 uV, v_off_fin = 2694.466 uV 15:54:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.662 uVs 15:54:53 Integrated Voltage Measurement... 15:55:02 Voltage Offset Correction: v_off_ini = 2711.804 uV, v_off_fin = 2701.949 uV 15:55:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.911 uVs 15:55:02 Integrated Voltage Measurement... 15:55:11 Voltage Offset Correction: v_off_ini = 2701.924 uV, v_off_fin = 2692.150 uV 15:55:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.667 uVs 15:55:11 Integrated Voltage Measurement... 15:55:20 Voltage Offset Correction: v_off_ini = 2698.402 uV, v_off_fin = 2690.009 uV 15:55:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.306 uVs 15:55:20 Integrated Voltage Measurement... 15:55:29 Voltage Offset Correction: v_off_ini = 2658.835 uV, v_off_fin = 2668.535 uV 15:55:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.375 uVs 15:55:31 I2Y Average and RMS of Measurements VT = -210.762 +- 1.866 uVs I2Y = -19.390 +- 0.172 uTm^2 15:55:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:55:40 Integrated Voltage Measurement... 15:55:49 Voltage Offset Correction: v_off_ini = 2685.100 uV, v_off_fin = 2671.697 uV 15:55:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.299 uVs 15:55:49 Integrated Voltage Measurement... 15:55:58 Voltage Offset Correction: v_off_ini = 2685.252 uV, v_off_fin = 2671.956 uV 15:55:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.455 uVs 15:55:58 Integrated Voltage Measurement... 15:56:07 Voltage Offset Correction: v_off_ini = 2667.051 uV, v_off_fin = 2646.228 uV 15:56:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.932 uVs 15:56:07 Integrated Voltage Measurement... 15:56:16 Voltage Offset Correction: v_off_ini = 2659.801 uV, v_off_fin = 2676.065 uV 15:56:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.429 uVs 15:56:16 Integrated Voltage Measurement... 15:56:25 Voltage Offset Correction: v_off_ini = 2694.709 uV, v_off_fin = 2684.524 uV 15:56:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.817 uVs 15:56:25 Integrated Voltage Measurement... 15:56:34 Voltage Offset Correction: v_off_ini = 2698.825 uV, v_off_fin = 2688.220 uV 15:56:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 168.517 uVs 15:56:38 I1X Average and RMS of Measurements VT = -140.908 +- 13.644 uVs I1X = 28.182 +- 2.729 uTm 15:56:41 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:56:45 Integrated Voltage Measurement... 15:56:54 Voltage Offset Correction: v_off_ini = 2697.617 uV, v_off_fin = 2676.068 uV 15:56:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.423 uVs 15:56:54 Integrated Voltage Measurement... 15:57:03 Voltage Offset Correction: v_off_ini = 2683.933 uV, v_off_fin = 2687.617 uV 15:57:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.921 uVs 15:57:03 Integrated Voltage Measurement... 15:57:12 Voltage Offset Correction: v_off_ini = 2723.653 uV, v_off_fin = 2685.433 uV 15:57:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.164 uVs 15:57:12 Integrated Voltage Measurement... 15:57:21 Voltage Offset Correction: v_off_ini = 2693.948 uV, v_off_fin = 2724.780 uV 15:57:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.586 uVs 15:57:21 Integrated Voltage Measurement... 15:57:30 Voltage Offset Correction: v_off_ini = 2709.377 uV, v_off_fin = 2682.300 uV 15:57:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.705 uVs 15:57:30 Integrated Voltage Measurement... 15:57:39 Voltage Offset Correction: v_off_ini = 2699.525 uV, v_off_fin = 2717.800 uV 15:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.751 uVs 15:57:43 I1Y Average and RMS of Measurements VT = -216.425 +- 8.242 uVs I1Y = -43.285 +- 1.648 uTm 15:57:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:57:51 Integrated Voltage Measurement... 15:58:00 Voltage Offset Correction: v_off_ini = 2697.041 uV, v_off_fin = 2682.300 uV 15:58:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.738 uVs 15:58:00 Integrated Voltage Measurement... 15:58:09 Voltage Offset Correction: v_off_ini = 2693.753 uV, v_off_fin = 2697.258 uV 15:58:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.610 uVs 15:58:09 Integrated Voltage Measurement... 15:58:18 Voltage Offset Correction: v_off_ini = 2697.702 uV, v_off_fin = 2694.527 uV 15:58:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -113.879 uVs 15:58:18 Integrated Voltage Measurement... 15:58:27 Voltage Offset Correction: v_off_ini = 2718.068 uV, v_off_fin = 2722.854 uV 15:58:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 89.372 uVs 15:58:27 Integrated Voltage Measurement... 15:58:36 Voltage Offset Correction: v_off_ini = 2705.645 uV, v_off_fin = 2706.013 uV 15:58:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.267 uVs 15:58:36 Integrated Voltage Measurement... 15:58:45 Voltage Offset Correction: v_off_ini = 2714.065 uV, v_off_fin = 2718.667 uV 15:58:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 100.477 uVs 15:58:47 I2X Average and RMS of Measurements VT = -90.891 +- 8.380 uVs I2X = 8.362 +- 0.771 uTm^2 15:58:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 15:58:55 Integrated Voltage Measurement... 15:59:04 Voltage Offset Correction: v_off_ini = 2727.333 uV, v_off_fin = 2711.640 uV 15:59:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -225.542 uVs 15:59:04 Integrated Voltage Measurement... 15:59:13 Voltage Offset Correction: v_off_ini = 2714.052 uV, v_off_fin = 2707.763 uV 15:59:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.542 uVs 15:59:13 Integrated Voltage Measurement... 15:59:22 Voltage Offset Correction: v_off_ini = 2680.069 uV, v_off_fin = 2700.870 uV 15:59:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -214.296 uVs 15:59:22 Integrated Voltage Measurement... 15:59:31 Voltage Offset Correction: v_off_ini = 2690.406 uV, v_off_fin = 2678.272 uV 15:59:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.264 uVs 15:59:31 Integrated Voltage Measurement... 15:59:40 Voltage Offset Correction: v_off_ini = 2686.785 uV, v_off_fin = 2677.992 uV 15:59:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -206.970 uVs 15:59:40 Integrated Voltage Measurement... 15:59:49 Voltage Offset Correction: v_off_ini = 2683.605 uV, v_off_fin = 2690.274 uV 15:59:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.368 uVs 15:59:52 I2Y Average and RMS of Measurements VT = -210.663 +- 7.290 uVs I2Y = -19.381 +- 0.671 uTm^2 15:59:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:00:04 Integrated Voltage Measurement... 16:00:13 Voltage Offset Correction: v_off_ini = 2712.207 uV, v_off_fin = 2700.343 uV 16:00:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -132.291 uVs 16:00:13 Integrated Voltage Measurement... 16:00:22 Voltage Offset Correction: v_off_ini = 2705.505 uV, v_off_fin = 2726.848 uV 16:00:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 152.411 uVs 16:00:22 Integrated Voltage Measurement... 16:00:31 Voltage Offset Correction: v_off_ini = 2713.279 uV, v_off_fin = 2727.811 uV 16:00:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -137.084 uVs 16:00:31 Integrated Voltage Measurement... 16:00:40 Voltage Offset Correction: v_off_ini = 2715.872 uV, v_off_fin = 2709.203 uV 16:00:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 161.622 uVs 16:00:40 Integrated Voltage Measurement... 16:00:49 Voltage Offset Correction: v_off_ini = 2693.437 uV, v_off_fin = 2701.485 uV 16:00:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -113.262 uVs 16:00:49 Integrated Voltage Measurement... 16:00:58 Voltage Offset Correction: v_off_ini = 2708.443 uV, v_off_fin = 2702.272 uV 16:00:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 141.706 uVs 16:01:02 I1X Average and RMS of Measurements VT = -139.729 +- 9.118 uVs I1X = 27.947 +- 1.824 uTm 16:01:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:01:09 Integrated Voltage Measurement... 16:01:18 Voltage Offset Correction: v_off_ini = 2679.931 uV, v_off_fin = 2672.494 uV 16:01:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.641 uVs 16:01:18 Integrated Voltage Measurement... 16:01:27 Voltage Offset Correction: v_off_ini = 2668.017 uV, v_off_fin = 2700.771 uV 16:01:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.339 uVs 16:01:27 Integrated Voltage Measurement... 16:01:36 Voltage Offset Correction: v_off_ini = 2683.062 uV, v_off_fin = 2688.575 uV 16:01:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -199.950 uVs 16:01:36 Integrated Voltage Measurement... 16:01:45 Voltage Offset Correction: v_off_ini = 2709.248 uV, v_off_fin = 2712.051 uV 16:01:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.287 uVs 16:01:45 Integrated Voltage Measurement... 16:01:54 Voltage Offset Correction: v_off_ini = 2694.212 uV, v_off_fin = 2689.207 uV 16:01:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.954 uVs 16:01:54 Integrated Voltage Measurement... 16:02:03 Voltage Offset Correction: v_off_ini = 2699.504 uV, v_off_fin = 2701.884 uV 16:02:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.599 uVs 16:02:07 I1Y Average and RMS of Measurements VT = -213.462 +- 2.536 uVs I1Y = -42.692 +- 0.507 uTm 16:02:09 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:02:12 Integrated Voltage Measurement... 16:02:21 Voltage Offset Correction: v_off_ini = 2708.496 uV, v_off_fin = 2708.031 uV 16:02:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.878 uVs 16:02:21 Integrated Voltage Measurement... 16:02:30 Voltage Offset Correction: v_off_ini = 2737.071 uV, v_off_fin = 2742.122 uV 16:02:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.304 uVs 16:02:30 Integrated Voltage Measurement... 16:02:39 Voltage Offset Correction: v_off_ini = 2691.649 uV, v_off_fin = 2708.355 uV 16:02:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.169 uVs 16:02:39 Integrated Voltage Measurement... 16:02:48 Voltage Offset Correction: v_off_ini = 2746.631 uV, v_off_fin = 2734.220 uV 16:02:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.821 uVs 16:02:48 Integrated Voltage Measurement... 16:02:57 Voltage Offset Correction: v_off_ini = 2714.621 uV, v_off_fin = 2704.845 uV 16:02:57 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -96.322 uVs 16:02:57 Integrated Voltage Measurement... 16:03:06 Voltage Offset Correction: v_off_ini = 2702.554 uV, v_off_fin = 2705.401 uV 16:03:06 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 131.491 uVs 16:03:08 I2X Average and RMS of Measurements VT = -93.997 +- 15.336 uVs I2X = 8.648 +- 1.411 uTm^2 16:03:11 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:03:14 Integrated Voltage Measurement... 16:03:23 Voltage Offset Correction: v_off_ini = 2702.349 uV, v_off_fin = 2715.220 uV 16:03:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.532 uVs 16:03:23 Integrated Voltage Measurement... 16:03:32 Voltage Offset Correction: v_off_ini = 2742.153 uV, v_off_fin = 2744.003 uV 16:03:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.597 uVs 16:03:32 Integrated Voltage Measurement... 16:03:41 Voltage Offset Correction: v_off_ini = 2729.383 uV, v_off_fin = 2719.701 uV 16:03:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.075 uVs 16:03:41 Integrated Voltage Measurement... 16:03:50 Voltage Offset Correction: v_off_ini = 2712.308 uV, v_off_fin = 2735.472 uV 16:03:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.696 uVs 16:03:50 Integrated Voltage Measurement... 16:03:59 Voltage Offset Correction: v_off_ini = 2742.183 uV, v_off_fin = 2741.858 uV 16:03:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.708 uVs 16:03:59 Integrated Voltage Measurement... 16:04:08 Voltage Offset Correction: v_off_ini = 2727.186 uV, v_off_fin = 2733.906 uV 16:04:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.419 uVs 16:04:10 I2Y Average and RMS of Measurements VT = -205.838 +- 8.732 uVs I2Y = -18.937 +- 0.803 uTm^2 16:04:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:04:18 Integrated Voltage Measurement... 16:04:27 Voltage Offset Correction: v_off_ini = 2736.579 uV, v_off_fin = 2725.259 uV 16:04:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -158.669 uVs 16:04:27 Integrated Voltage Measurement... 16:04:36 Voltage Offset Correction: v_off_ini = 2713.188 uV, v_off_fin = 2720.366 uV 16:04:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 150.773 uVs 16:04:36 Integrated Voltage Measurement... 16:04:45 Voltage Offset Correction: v_off_ini = 2707.761 uV, v_off_fin = 2703.556 uV 16:04:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -154.702 uVs 16:04:45 Integrated Voltage Measurement... 16:04:54 Voltage Offset Correction: v_off_ini = 2722.534 uV, v_off_fin = 2716.891 uV 16:04:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.398 uVs 16:04:54 Integrated Voltage Measurement... 16:05:03 Voltage Offset Correction: v_off_ini = 2719.271 uV, v_off_fin = 2710.795 uV 16:05:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -140.908 uVs 16:05:03 Integrated Voltage Measurement... 16:05:12 Voltage Offset Correction: v_off_ini = 2711.509 uV, v_off_fin = 2710.472 uV 16:05:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.870 uVs 16:05:17 I1X Average and RMS of Measurements VT = -148.220 +- 6.766 uVs I1X = 29.645 +- 1.354 uTm 16:05:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:05:23 Integrated Voltage Measurement... 16:05:32 Voltage Offset Correction: v_off_ini = 2709.891 uV, v_off_fin = 2713.132 uV 16:05:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.813 uVs 16:05:32 Integrated Voltage Measurement... 16:05:41 Voltage Offset Correction: v_off_ini = 2719.050 uV, v_off_fin = 2759.082 uV 16:05:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.244 uVs 16:05:41 Integrated Voltage Measurement... 16:05:50 Voltage Offset Correction: v_off_ini = 2730.253 uV, v_off_fin = 2733.113 uV 16:05:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -208.303 uVs 16:05:50 Integrated Voltage Measurement... 16:05:59 Voltage Offset Correction: v_off_ini = 2766.185 uV, v_off_fin = 2770.373 uV 16:05:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.334 uVs 16:05:59 Integrated Voltage Measurement... 16:06:08 Voltage Offset Correction: v_off_ini = 2748.149 uV, v_off_fin = 2754.980 uV 16:06:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.224 uVs 16:06:08 Integrated Voltage Measurement... 16:06:17 Voltage Offset Correction: v_off_ini = 2734.063 uV, v_off_fin = 2744.239 uV 16:06:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.900 uVs 16:06:22 I1Y Average and RMS of Measurements VT = -211.470 +- 5.346 uVs I1Y = -42.294 +- 1.069 uTm 16:06:24 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:06:27 Integrated Voltage Measurement... 16:06:36 Voltage Offset Correction: v_off_ini = 2710.073 uV, v_off_fin = 2702.152 uV 16:06:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -92.981 uVs 16:06:36 Integrated Voltage Measurement... 16:06:45 Voltage Offset Correction: v_off_ini = 2708.930 uV, v_off_fin = 2719.297 uV 16:06:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.057 uVs 16:06:45 Integrated Voltage Measurement... 16:06:54 Voltage Offset Correction: v_off_ini = 2727.283 uV, v_off_fin = 2711.696 uV 16:06:54 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -93.291 uVs 16:06:54 Integrated Voltage Measurement... 16:07:03 Voltage Offset Correction: v_off_ini = 2725.813 uV, v_off_fin = 2710.899 uV 16:07:03 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 76.725 uVs 16:07:03 Integrated Voltage Measurement... 16:07:12 Voltage Offset Correction: v_off_ini = 2723.954 uV, v_off_fin = 2731.557 uV 16:07:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -98.112 uVs 16:07:12 Integrated Voltage Measurement... 16:07:21 Voltage Offset Correction: v_off_ini = 2719.153 uV, v_off_fin = 2725.458 uV 16:07:21 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 58.531 uVs 16:07:23 I2X Average and RMS of Measurements VT = -88.450 +- 9.976 uVs I2X = 8.138 +- 0.917 uTm^2 16:07:26 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:07:28 Integrated Voltage Measurement... 16:07:37 Voltage Offset Correction: v_off_ini = 2744.640 uV, v_off_fin = 2741.376 uV 16:07:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.393 uVs 16:07:37 Integrated Voltage Measurement... 16:07:46 Voltage Offset Correction: v_off_ini = 2740.564 uV, v_off_fin = 2740.161 uV 16:07:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.690 uVs 16:07:46 Integrated Voltage Measurement... 16:07:55 Voltage Offset Correction: v_off_ini = 2738.672 uV, v_off_fin = 2743.250 uV 16:07:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.828 uVs 16:07:55 Integrated Voltage Measurement... 16:08:04 Voltage Offset Correction: v_off_ini = 2739.942 uV, v_off_fin = 2743.506 uV 16:08:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 219.984 uVs 16:08:04 Integrated Voltage Measurement... 16:08:13 Voltage Offset Correction: v_off_ini = 2733.735 uV, v_off_fin = 2745.512 uV 16:08:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.980 uVs 16:08:13 Integrated Voltage Measurement... 16:08:22 Voltage Offset Correction: v_off_ini = 2741.726 uV, v_off_fin = 2750.345 uV 16:08:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.380 uVs 16:08:25 I2Y Average and RMS of Measurements VT = -200.542 +- 9.510 uVs I2Y = -18.450 +- 0.875 uTm^2 16:08:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:08:33 Integrated Voltage Measurement... 16:08:42 Voltage Offset Correction: v_off_ini = 2775.263 uV, v_off_fin = 2764.732 uV 16:08:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -166.651 uVs 16:08:42 Integrated Voltage Measurement... 16:08:51 Voltage Offset Correction: v_off_ini = 2761.753 uV, v_off_fin = 2776.340 uV 16:08:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.452 uVs 16:08:51 Integrated Voltage Measurement... 16:09:00 Voltage Offset Correction: v_off_ini = 2780.695 uV, v_off_fin = 2784.516 uV 16:09:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -139.403 uVs 16:09:00 Integrated Voltage Measurement... 16:09:09 Voltage Offset Correction: v_off_ini = 2763.445 uV, v_off_fin = 2781.568 uV 16:09:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.383 uVs 16:09:09 Integrated Voltage Measurement... 16:09:18 Voltage Offset Correction: v_off_ini = 2760.143 uV, v_off_fin = 2784.065 uV 16:09:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -144.976 uVs 16:09:18 Integrated Voltage Measurement... 16:09:27 Voltage Offset Correction: v_off_ini = 2766.940 uV, v_off_fin = 2785.066 uV 16:09:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 155.698 uVs 16:09:31 I1X Average and RMS of Measurements VT = -147.094 +- 2.853 uVs I1X = 29.419 +- 0.571 uTm 16:09:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:09:38 Integrated Voltage Measurement... 16:09:47 Voltage Offset Correction: v_off_ini = 2777.000 uV, v_off_fin = 2760.864 uV 16:09:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -207.588 uVs 16:09:47 Integrated Voltage Measurement... 16:09:56 Voltage Offset Correction: v_off_ini = 2764.877 uV, v_off_fin = 2765.237 uV 16:09:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.637 uVs 16:09:56 Integrated Voltage Measurement... 16:10:05 Voltage Offset Correction: v_off_ini = 2763.951 uV, v_off_fin = 2759.645 uV 16:10:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.886 uVs 16:10:05 Integrated Voltage Measurement... 16:10:14 Voltage Offset Correction: v_off_ini = 2781.031 uV, v_off_fin = 2776.912 uV 16:10:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.567 uVs 16:10:14 Integrated Voltage Measurement... 16:10:23 Voltage Offset Correction: v_off_ini = 2782.791 uV, v_off_fin = 2764.680 uV 16:10:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.680 uVs 16:10:23 Integrated Voltage Measurement... 16:10:32 Voltage Offset Correction: v_off_ini = 2767.317 uV, v_off_fin = 2774.269 uV 16:10:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.728 uVs 16:10:36 I1Y Average and RMS of Measurements VT = -205.014 +- 2.094 uVs I1Y = -41.003 +- 0.419 uTm 16:10:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:10:41 Integrated Voltage Measurement... 16:10:50 Voltage Offset Correction: v_off_ini = 2776.814 uV, v_off_fin = 2778.633 uV 16:10:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.597 uVs 16:10:50 Integrated Voltage Measurement... 16:10:59 Voltage Offset Correction: v_off_ini = 2767.254 uV, v_off_fin = 2771.738 uV 16:10:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.327 uVs 16:10:59 Integrated Voltage Measurement... 16:11:08 Voltage Offset Correction: v_off_ini = 2782.089 uV, v_off_fin = 2757.791 uV 16:11:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.069 uVs 16:11:08 Integrated Voltage Measurement... 16:11:17 Voltage Offset Correction: v_off_ini = 2758.354 uV, v_off_fin = 2768.653 uV 16:11:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 114.003 uVs 16:11:17 Integrated Voltage Measurement... 16:11:26 Voltage Offset Correction: v_off_ini = 2763.422 uV, v_off_fin = 2774.625 uV 16:11:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.105 uVs 16:11:26 Integrated Voltage Measurement... 16:11:35 Voltage Offset Correction: v_off_ini = 2812.097 uV, v_off_fin = 2789.198 uV 16:11:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 77.160 uVs 16:11:38 I2X Average and RMS of Measurements VT = -101.377 +- 2.724 uVs I2X = 9.327 +- 0.251 uTm^2 16:11:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:11:43 Integrated Voltage Measurement... 16:11:52 Voltage Offset Correction: v_off_ini = 2772.404 uV, v_off_fin = 2769.411 uV 16:11:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.857 uVs 16:11:52 Integrated Voltage Measurement... 16:12:01 Voltage Offset Correction: v_off_ini = 2768.580 uV, v_off_fin = 2769.639 uV 16:12:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.422 uVs 16:12:01 Integrated Voltage Measurement... 16:12:10 Voltage Offset Correction: v_off_ini = 2770.364 uV, v_off_fin = 2751.058 uV 16:12:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -217.597 uVs 16:12:10 Integrated Voltage Measurement... 16:12:19 Voltage Offset Correction: v_off_ini = 2780.764 uV, v_off_fin = 2782.069 uV 16:12:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.329 uVs 16:12:19 Integrated Voltage Measurement... 16:12:28 Voltage Offset Correction: v_off_ini = 2779.384 uV, v_off_fin = 2768.942 uV 16:12:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.912 uVs 16:12:28 Integrated Voltage Measurement... 16:12:37 Voltage Offset Correction: v_off_ini = 2768.789 uV, v_off_fin = 2795.583 uV 16:12:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.603 uVs 16:12:39 I2Y Average and RMS of Measurements VT = -197.453 +- 4.617 uVs I2Y = -18.166 +- 0.425 uTm^2 16:12:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:12:48 Integrated Voltage Measurement... 16:12:57 Voltage Offset Correction: v_off_ini = 2786.938 uV, v_off_fin = 2789.141 uV 16:12:57 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -156.686 uVs 16:12:57 Integrated Voltage Measurement... 16:13:06 Voltage Offset Correction: v_off_ini = 2776.547 uV, v_off_fin = 2781.615 uV 16:13:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.706 uVs 16:13:06 Integrated Voltage Measurement... 16:13:15 Voltage Offset Correction: v_off_ini = 2784.266 uV, v_off_fin = 2795.718 uV 16:13:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.465 uVs 16:13:15 Integrated Voltage Measurement... 16:13:24 Voltage Offset Correction: v_off_ini = 2794.286 uV, v_off_fin = 2792.893 uV 16:13:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.431 uVs 16:13:24 Integrated Voltage Measurement... 16:13:33 Voltage Offset Correction: v_off_ini = 2778.087 uV, v_off_fin = 2775.611 uV 16:13:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -116.241 uVs 16:13:33 Integrated Voltage Measurement... 16:13:42 Voltage Offset Correction: v_off_ini = 2771.759 uV, v_off_fin = 2786.091 uV 16:13:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.548 uVs 16:13:46 I1X Average and RMS of Measurements VT = -129.346 +- 8.735 uVs I1X = 25.870 +- 1.748 uTm 16:13:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:13:53 Integrated Voltage Measurement... 16:14:02 Voltage Offset Correction: v_off_ini = 2773.826 uV, v_off_fin = 2758.762 uV 16:14:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -201.711 uVs 16:14:02 Integrated Voltage Measurement... 16:14:11 Voltage Offset Correction: v_off_ini = 2777.676 uV, v_off_fin = 2783.142 uV 16:14:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.428 uVs 16:14:11 Integrated Voltage Measurement... 16:14:20 Voltage Offset Correction: v_off_ini = 2786.584 uV, v_off_fin = 2774.669 uV 16:14:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.428 uVs 16:14:20 Integrated Voltage Measurement... 16:14:29 Voltage Offset Correction: v_off_ini = 2768.681 uV, v_off_fin = 2782.772 uV 16:14:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.291 uVs 16:14:29 Integrated Voltage Measurement... 16:14:38 Voltage Offset Correction: v_off_ini = 2791.075 uV, v_off_fin = 2779.163 uV 16:14:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.398 uVs 16:14:38 Integrated Voltage Measurement... 16:14:47 Voltage Offset Correction: v_off_ini = 2774.908 uV, v_off_fin = 2786.877 uV 16:14:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.189 uVs 16:14:51 I1Y Average and RMS of Measurements VT = -200.241 +- 6.252 uVs I1Y = -40.048 +- 1.250 uTm 16:14:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:14:56 Integrated Voltage Measurement... 16:15:05 Voltage Offset Correction: v_off_ini = 2798.191 uV, v_off_fin = 2779.235 uV 16:15:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -128.678 uVs 16:15:05 Integrated Voltage Measurement... 16:15:14 Voltage Offset Correction: v_off_ini = 2809.702 uV, v_off_fin = 2806.616 uV 16:15:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.603 uVs 16:15:14 Integrated Voltage Measurement... 16:15:23 Voltage Offset Correction: v_off_ini = 2812.160 uV, v_off_fin = 2811.599 uV 16:15:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.776 uVs 16:15:23 Integrated Voltage Measurement... 16:15:32 Voltage Offset Correction: v_off_ini = 2809.605 uV, v_off_fin = 2811.021 uV 16:15:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 86.037 uVs 16:15:32 Integrated Voltage Measurement... 16:15:41 Voltage Offset Correction: v_off_ini = 2787.578 uV, v_off_fin = 2782.790 uV 16:15:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.137 uVs 16:15:41 Integrated Voltage Measurement... 16:15:50 Voltage Offset Correction: v_off_ini = 2814.104 uV, v_off_fin = 2808.885 uV 16:15:50 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 104.889 uVs 16:15:52 I2X Average and RMS of Measurements VT = -108.687 +- 9.946 uVs I2X = 9.999 +- 0.915 uTm^2 16:15:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:15:57 Integrated Voltage Measurement... 16:16:06 Voltage Offset Correction: v_off_ini = 2775.706 uV, v_off_fin = 2778.012 uV 16:16:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -179.238 uVs 16:16:07 Integrated Voltage Measurement... 16:16:15 Voltage Offset Correction: v_off_ini = 2820.335 uV, v_off_fin = 2824.513 uV 16:16:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.018 uVs 16:16:16 Integrated Voltage Measurement... 16:16:25 Voltage Offset Correction: v_off_ini = 2805.257 uV, v_off_fin = 2804.338 uV 16:16:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.013 uVs 16:16:25 Integrated Voltage Measurement... 16:16:34 Voltage Offset Correction: v_off_ini = 2806.240 uV, v_off_fin = 2779.053 uV 16:16:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 193.964 uVs 16:16:34 Integrated Voltage Measurement... 16:16:43 Voltage Offset Correction: v_off_ini = 2783.558 uV, v_off_fin = 2795.033 uV 16:16:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.711 uVs 16:16:43 Integrated Voltage Measurement... 16:16:52 Voltage Offset Correction: v_off_ini = 2796.925 uV, v_off_fin = 2781.305 uV 16:16:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 163.162 uVs 16:16:54 I2Y Average and RMS of Measurements VT = -187.684 +- 0.532 uVs I2Y = -17.267 +- 0.049 uTm^2 16:16:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:17:02 Integrated Voltage Measurement... 16:17:11 Voltage Offset Correction: v_off_ini = 2776.460 uV, v_off_fin = 2754.320 uV 16:17:11 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -154.936 uVs 16:17:11 Integrated Voltage Measurement... 16:17:20 Voltage Offset Correction: v_off_ini = 2745.586 uV, v_off_fin = 2780.420 uV 16:17:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 111.160 uVs 16:17:20 Integrated Voltage Measurement... 16:17:29 Voltage Offset Correction: v_off_ini = 2789.004 uV, v_off_fin = 2790.117 uV 16:17:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -132.274 uVs 16:17:29 Integrated Voltage Measurement... 16:17:38 Voltage Offset Correction: v_off_ini = 2754.079 uV, v_off_fin = 2779.878 uV 16:17:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 142.645 uVs 16:17:38 Integrated Voltage Measurement... 16:17:47 Voltage Offset Correction: v_off_ini = 2765.142 uV, v_off_fin = 2760.459 uV 16:17:47 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -157.219 uVs 16:17:47 Integrated Voltage Measurement... 16:17:56 Voltage Offset Correction: v_off_ini = 2766.569 uV, v_off_fin = 2793.541 uV 16:17:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 107.450 uVs 16:18:01 I1X Average and RMS of Measurements VT = -134.281 +- 2.267 uVs I1X = 26.860 +- 0.453 uTm 16:18:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:18:07 Integrated Voltage Measurement... 16:18:16 Voltage Offset Correction: v_off_ini = 2768.915 uV, v_off_fin = 2764.035 uV 16:18:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.295 uVs 16:18:16 Integrated Voltage Measurement... 16:18:25 Voltage Offset Correction: v_off_ini = 2761.472 uV, v_off_fin = 2787.607 uV 16:18:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.764 uVs 16:18:25 Integrated Voltage Measurement... 16:18:34 Voltage Offset Correction: v_off_ini = 2800.692 uV, v_off_fin = 2775.245 uV 16:18:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -211.871 uVs 16:18:34 Integrated Voltage Measurement... 16:18:43 Voltage Offset Correction: v_off_ini = 2772.945 uV, v_off_fin = 2792.117 uV 16:18:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 235.606 uVs 16:18:43 Integrated Voltage Measurement... 16:18:52 Voltage Offset Correction: v_off_ini = 2797.449 uV, v_off_fin = 2782.886 uV 16:18:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -187.495 uVs 16:18:52 Integrated Voltage Measurement... 16:19:01 Voltage Offset Correction: v_off_ini = 2797.624 uV, v_off_fin = 2782.465 uV 16:19:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 206.359 uVs 16:19:06 I1Y Average and RMS of Measurements VT = -207.398 +- 11.706 uVs I1Y = -41.477 +- 2.340 uTm 16:19:08 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:19:11 Integrated Voltage Measurement... 16:19:20 Voltage Offset Correction: v_off_ini = 2804.473 uV, v_off_fin = 2794.424 uV 16:19:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -123.987 uVs 16:19:20 Integrated Voltage Measurement... 16:19:29 Voltage Offset Correction: v_off_ini = 2801.885 uV, v_off_fin = 2806.627 uV 16:19:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.988 uVs 16:19:29 Integrated Voltage Measurement... 16:19:38 Voltage Offset Correction: v_off_ini = 2793.005 uV, v_off_fin = 2785.229 uV 16:19:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.835 uVs 16:19:38 Integrated Voltage Measurement... 16:19:47 Voltage Offset Correction: v_off_ini = 2787.947 uV, v_off_fin = 2792.735 uV 16:19:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 82.857 uVs 16:19:47 Integrated Voltage Measurement... 16:19:56 Voltage Offset Correction: v_off_ini = 2774.896 uV, v_off_fin = 2759.529 uV 16:19:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.026 uVs 16:19:56 Integrated Voltage Measurement... 16:20:05 Voltage Offset Correction: v_off_ini = 2768.762 uV, v_off_fin = 2775.817 uV 16:20:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.903 uVs 16:20:07 I2X Average and RMS of Measurements VT = -96.266 +- 15.069 uVs I2X = 8.856 +- 1.386 uTm^2 16:20:10 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 16:20:12 Integrated Voltage Measurement... 16:20:21 Voltage Offset Correction: v_off_ini = 2777.046 uV, v_off_fin = 2739.881 uV 16:20:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -176.401 uVs 16:20:21 Integrated Voltage Measurement... 16:20:30 Voltage Offset Correction: v_off_ini = 2744.014 uV, v_off_fin = 2732.027 uV 16:20:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.376 uVs 16:20:30 Integrated Voltage Measurement... 16:20:39 Voltage Offset Correction: v_off_ini = 2757.883 uV, v_off_fin = 2759.600 uV 16:20:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.085 uVs 16:20:39 Integrated Voltage Measurement... 16:20:48 Voltage Offset Correction: v_off_ini = 2754.794 uV, v_off_fin = 2750.841 uV 16:20:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.684 uVs 16:20:48 Integrated Voltage Measurement... 16:20:57 Voltage Offset Correction: v_off_ini = 2743.353 uV, v_off_fin = 2746.748 uV 16:20:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.910 uVs 16:20:57 Integrated Voltage Measurement... 16:21:06 Voltage Offset Correction: v_off_ini = 2751.045 uV, v_off_fin = 2771.389 uV 16:21:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.119 uVs 16:21:09 I2Y Average and RMS of Measurements VT = -192.762 +- 7.884 uVs I2Y = -17.734 +- 0.725 uTm^2 16:21:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:21:30 Integrated Voltage Measurement... 16:21:39 Voltage Offset Correction: v_off_ini = 2793.044 uV, v_off_fin = 2795.193 uV 16:21:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -151.806 uVs 16:21:39 Integrated Voltage Measurement... 16:21:48 Voltage Offset Correction: v_off_ini = 2797.563 uV, v_off_fin = 2794.250 uV 16:21:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 122.821 uVs 16:21:48 Integrated Voltage Measurement... 16:21:57 Voltage Offset Correction: v_off_ini = 2804.150 uV, v_off_fin = 2798.752 uV 16:21:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -132.215 uVs 16:21:57 Integrated Voltage Measurement... 16:22:06 Voltage Offset Correction: v_off_ini = 2824.363 uV, v_off_fin = 2816.733 uV 16:22:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.900 uVs 16:22:06 Integrated Voltage Measurement... 16:22:15 Voltage Offset Correction: v_off_ini = 2799.899 uV, v_off_fin = 2773.790 uV 16:22:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.046 uVs 16:22:15 Integrated Voltage Measurement... 16:22:24 Voltage Offset Correction: v_off_ini = 2824.448 uV, v_off_fin = 2829.555 uV 16:22:24 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 135.241 uVs 16:22:28 I1X Average and RMS of Measurements VT = -137.005 +- 5.551 uVs I1X = 27.403 +- 1.111 uTm 16:22:31 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:22:35 Integrated Voltage Measurement... 16:22:44 Voltage Offset Correction: v_off_ini = 2835.214 uV, v_off_fin = 2799.893 uV 16:22:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.308 uVs 16:22:44 Integrated Voltage Measurement... 16:22:53 Voltage Offset Correction: v_off_ini = 2793.888 uV, v_off_fin = 2824.490 uV 16:22:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.967 uVs 16:22:53 Integrated Voltage Measurement... 16:23:02 Voltage Offset Correction: v_off_ini = 2784.560 uV, v_off_fin = 2779.693 uV 16:23:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.537 uVs 16:23:02 Integrated Voltage Measurement... 16:23:11 Voltage Offset Correction: v_off_ini = 2810.727 uV, v_off_fin = 2813.650 uV 16:23:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 194.467 uVs 16:23:11 Integrated Voltage Measurement... 16:23:20 Voltage Offset Correction: v_off_ini = 2801.803 uV, v_off_fin = 2772.930 uV 16:23:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -210.212 uVs 16:23:20 Integrated Voltage Measurement... 16:23:29 Voltage Offset Correction: v_off_ini = 2788.004 uV, v_off_fin = 2787.925 uV 16:23:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.819 uVs 16:23:33 I1Y Average and RMS of Measurements VT = -205.552 +- 2.332 uVs I1Y = -41.110 +- 0.466 uTm 16:23:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:23:41 Integrated Voltage Measurement... 16:23:50 Voltage Offset Correction: v_off_ini = 2752.566 uV, v_off_fin = 2752.726 uV 16:23:50 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -92.815 uVs 16:23:50 Integrated Voltage Measurement... 16:23:59 Voltage Offset Correction: v_off_ini = 2755.492 uV, v_off_fin = 2767.052 uV 16:23:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.972 uVs 16:23:59 Integrated Voltage Measurement... 16:24:08 Voltage Offset Correction: v_off_ini = 2747.776 uV, v_off_fin = 2749.620 uV 16:24:08 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -115.168 uVs 16:24:08 Integrated Voltage Measurement... 16:24:17 Voltage Offset Correction: v_off_ini = 2795.579 uV, v_off_fin = 2792.429 uV 16:24:17 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 107.955 uVs 16:24:17 Integrated Voltage Measurement... 16:24:26 Voltage Offset Correction: v_off_ini = 2758.762 uV, v_off_fin = 2732.004 uV 16:24:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.603 uVs 16:24:26 Integrated Voltage Measurement... 16:24:35 Voltage Offset Correction: v_off_ini = 2758.096 uV, v_off_fin = 2758.736 uV 16:24:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 113.871 uVs 16:24:37 I2X Average and RMS of Measurements VT = -109.564 +- 6.421 uVs I2X = 10.080 +- 0.591 uTm^2 16:24:42 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 16:24:45 Integrated Voltage Measurement... 16:24:54 Voltage Offset Correction: v_off_ini = 2783.279 uV, v_off_fin = 2769.577 uV 16:24:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -180.619 uVs 16:24:54 Integrated Voltage Measurement... 16:25:03 Voltage Offset Correction: v_off_ini = 2788.179 uV, v_off_fin = 2779.427 uV 16:25:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.789 uVs 16:25:03 Integrated Voltage Measurement... 16:25:12 Voltage Offset Correction: v_off_ini = 2776.109 uV, v_off_fin = 2769.752 uV 16:25:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.391 uVs 16:25:12 Integrated Voltage Measurement... 16:25:21 Voltage Offset Correction: v_off_ini = 2753.838 uV, v_off_fin = 2746.573 uV 16:25:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 170.350 uVs 16:25:21 Integrated Voltage Measurement... 16:25:30 Voltage Offset Correction: v_off_ini = 2785.979 uV, v_off_fin = 2773.715 uV 16:25:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.724 uVs 16:25:30 Integrated Voltage Measurement... 16:25:39 Voltage Offset Correction: v_off_ini = 2761.672 uV, v_off_fin = 2756.852 uV 16:25:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.381 uVs 16:25:42 I2Y Average and RMS of Measurements VT = -190.542 +- 7.062 uVs I2Y = -17.530 +- 0.650 uTm^2 16:25:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:25:51 Integrated Voltage Measurement... 16:25:59 Voltage Offset Correction: v_off_ini = 2747.537 uV, v_off_fin = 2746.847 uV 16:26:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -143.816 uVs 16:26:00 Integrated Voltage Measurement... 16:26:08 Voltage Offset Correction: v_off_ini = 2760.130 uV, v_off_fin = 2766.438 uV 16:26:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 156.237 uVs 16:26:09 Integrated Voltage Measurement... 16:26:17 Voltage Offset Correction: v_off_ini = 2736.682 uV, v_off_fin = 2721.784 uV 16:26:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -158.754 uVs 16:26:18 Integrated Voltage Measurement... 16:26:27 Voltage Offset Correction: v_off_ini = 2714.849 uV, v_off_fin = 2728.947 uV 16:26:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 148.575 uVs 16:26:27 Integrated Voltage Measurement... 16:26:36 Voltage Offset Correction: v_off_ini = 2727.885 uV, v_off_fin = 2722.328 uV 16:26:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -138.202 uVs 16:26:36 Integrated Voltage Measurement... 16:26:45 Voltage Offset Correction: v_off_ini = 2760.164 uV, v_off_fin = 2784.735 uV 16:26:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 159.966 uVs 16:26:49 I1X Average and RMS of Measurements VT = -150.925 +- 1.975 uVs I1X = 30.186 +- 0.395 uTm 16:26:51 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:26:55 Integrated Voltage Measurement... 16:27:04 Voltage Offset Correction: v_off_ini = 2717.491 uV, v_off_fin = 2709.045 uV 16:27:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.236 uVs 16:27:04 Integrated Voltage Measurement... 16:27:13 Voltage Offset Correction: v_off_ini = 2739.030 uV, v_off_fin = 2744.446 uV 16:27:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.750 uVs 16:27:13 Integrated Voltage Measurement... 16:27:22 Voltage Offset Correction: v_off_ini = 2731.119 uV, v_off_fin = 2737.417 uV 16:27:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.905 uVs 16:27:22 Integrated Voltage Measurement... 16:27:31 Voltage Offset Correction: v_off_ini = 2718.348 uV, v_off_fin = 2728.102 uV 16:27:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.256 uVs 16:27:31 Integrated Voltage Measurement... 16:27:40 Voltage Offset Correction: v_off_ini = 2715.754 uV, v_off_fin = 2719.468 uV 16:27:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.667 uVs 16:27:40 Integrated Voltage Measurement... 16:27:49 Voltage Offset Correction: v_off_ini = 2721.291 uV, v_off_fin = 2762.508 uV 16:27:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.262 uVs 16:27:54 I1Y Average and RMS of Measurements VT = -211.179 +- 6.520 uVs I1Y = -42.236 +- 1.304 uTm 16:27:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:28:01 Integrated Voltage Measurement... 16:28:10 Voltage Offset Correction: v_off_ini = 2727.126 uV, v_off_fin = 2715.776 uV 16:28:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -114.319 uVs 16:28:10 Integrated Voltage Measurement... 16:28:19 Voltage Offset Correction: v_off_ini = 2721.020 uV, v_off_fin = 2742.248 uV 16:28:19 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.765 uVs 16:28:19 Integrated Voltage Measurement... 16:28:28 Voltage Offset Correction: v_off_ini = 2728.814 uV, v_off_fin = 2731.927 uV 16:28:28 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -100.172 uVs 16:28:28 Integrated Voltage Measurement... 16:28:37 Voltage Offset Correction: v_off_ini = 2740.663 uV, v_off_fin = 2746.686 uV 16:28:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 100.611 uVs 16:28:37 Integrated Voltage Measurement... 16:28:46 Voltage Offset Correction: v_off_ini = 2729.677 uV, v_off_fin = 2721.985 uV 16:28:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -94.356 uVs 16:28:46 Integrated Voltage Measurement... 16:28:55 Voltage Offset Correction: v_off_ini = 2723.170 uV, v_off_fin = 2725.198 uV 16:28:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 106.176 uVs 16:28:58 I2X Average and RMS of Measurements VT = -104.733 +- 6.229 uVs I2X = 9.636 +- 0.573 uTm^2 16:29:03 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 16:29:05 Integrated Voltage Measurement... 16:29:14 Voltage Offset Correction: v_off_ini = 2729.151 uV, v_off_fin = 2715.938 uV 16:29:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.863 uVs 16:29:14 Integrated Voltage Measurement... 16:29:23 Voltage Offset Correction: v_off_ini = 2730.000 uV, v_off_fin = 2739.349 uV 16:29:23 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 215.578 uVs 16:29:23 Integrated Voltage Measurement... 16:29:32 Voltage Offset Correction: v_off_ini = 2726.364 uV, v_off_fin = 2735.625 uV 16:29:32 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -187.959 uVs 16:29:32 Integrated Voltage Measurement... 16:29:41 Voltage Offset Correction: v_off_ini = 2753.981 uV, v_off_fin = 2724.077 uV 16:29:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.177 uVs 16:29:42 Integrated Voltage Measurement... 16:29:51 Voltage Offset Correction: v_off_ini = 2722.264 uV, v_off_fin = 2700.330 uV 16:29:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -157.270 uVs 16:29:51 Integrated Voltage Measurement... 16:30:00 Voltage Offset Correction: v_off_ini = 2740.346 uV, v_off_fin = 2749.223 uV 16:30:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.231 uVs 16:30:02 I2Y Average and RMS of Measurements VT = -185.680 +- 12.299 uVs I2Y = -17.083 +- 1.132 uTm^2 16:30:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:30:11 Integrated Voltage Measurement... 16:30:20 Voltage Offset Correction: v_off_ini = 2746.339 uV, v_off_fin = 2754.949 uV 16:30:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -152.746 uVs 16:30:20 Integrated Voltage Measurement... 16:30:29 Voltage Offset Correction: v_off_ini = 2753.146 uV, v_off_fin = 2768.312 uV 16:30:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 146.710 uVs 16:30:29 Integrated Voltage Measurement... 16:30:38 Voltage Offset Correction: v_off_ini = 2747.270 uV, v_off_fin = 2758.991 uV 16:30:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -119.175 uVs 16:30:38 Integrated Voltage Measurement... 16:30:47 Voltage Offset Correction: v_off_ini = 2771.808 uV, v_off_fin = 2758.192 uV 16:30:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.859 uVs 16:30:47 Integrated Voltage Measurement... 16:30:56 Voltage Offset Correction: v_off_ini = 2756.816 uV, v_off_fin = 2775.200 uV 16:30:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -112.768 uVs 16:30:56 Integrated Voltage Measurement... 16:31:05 Voltage Offset Correction: v_off_ini = 2783.660 uV, v_off_fin = 2768.792 uV 16:31:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 117.334 uVs 16:31:09 I1X Average and RMS of Measurements VT = -127.099 +- 16.013 uVs I1X = 25.420 +- 3.203 uTm 16:31:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:31:16 Integrated Voltage Measurement... 16:31:25 Voltage Offset Correction: v_off_ini = 2767.832 uV, v_off_fin = 2765.992 uV 16:31:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.209 uVs 16:31:25 Integrated Voltage Measurement... 16:31:34 Voltage Offset Correction: v_off_ini = 2785.772 uV, v_off_fin = 2784.040 uV 16:31:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.333 uVs 16:31:34 Integrated Voltage Measurement... 16:31:43 Voltage Offset Correction: v_off_ini = 2770.364 uV, v_off_fin = 2763.914 uV 16:31:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.683 uVs 16:31:43 Integrated Voltage Measurement... 16:31:52 Voltage Offset Correction: v_off_ini = 2779.100 uV, v_off_fin = 2777.180 uV 16:31:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.384 uVs 16:31:52 Integrated Voltage Measurement... 16:32:01 Voltage Offset Correction: v_off_ini = 2773.629 uV, v_off_fin = 2762.263 uV 16:32:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.076 uVs 16:32:01 Integrated Voltage Measurement... 16:32:10 Voltage Offset Correction: v_off_ini = 2776.218 uV, v_off_fin = 2830.371 uV 16:32:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.325 uVs 16:32:14 I1Y Average and RMS of Measurements VT = -208.002 +- 7.623 uVs I1Y = -41.600 +- 1.525 uTm 16:32:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:32:22 Integrated Voltage Measurement... 16:32:30 Voltage Offset Correction: v_off_ini = 2819.058 uV, v_off_fin = 2797.492 uV 16:32:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -118.589 uVs 16:32:31 Integrated Voltage Measurement... 16:32:40 Voltage Offset Correction: v_off_ini = 2803.632 uV, v_off_fin = 2789.339 uV 16:32:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 112.563 uVs 16:32:40 Integrated Voltage Measurement... 16:32:49 Voltage Offset Correction: v_off_ini = 2800.667 uV, v_off_fin = 2787.168 uV 16:32:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -109.652 uVs 16:32:49 Integrated Voltage Measurement... 16:32:58 Voltage Offset Correction: v_off_ini = 2800.555 uV, v_off_fin = 2797.748 uV 16:32:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.214 uVs 16:32:58 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = 2788.300 uV, v_off_fin = 2783.059 uV 16:33:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -118.610 uVs 16:33:07 Integrated Voltage Measurement... 16:33:16 Voltage Offset Correction: v_off_ini = 2770.916 uV, v_off_fin = 2773.957 uV 16:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 112.467 uVs 16:33:18 I2X Average and RMS of Measurements VT = -109.182 +- 9.015 uVs I2X = 10.045 +- 0.830 uTm^2 16:33:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:33:26 Integrated Voltage Measurement... 16:33:35 Voltage Offset Correction: v_off_ini = 2776.861 uV, v_off_fin = 2771.649 uV 16:33:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -189.882 uVs 16:33:35 Integrated Voltage Measurement... 16:33:44 Voltage Offset Correction: v_off_ini = 2783.693 uV, v_off_fin = 2777.531 uV 16:33:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.618 uVs 16:33:44 Integrated Voltage Measurement... 16:33:53 Voltage Offset Correction: v_off_ini = 2763.387 uV, v_off_fin = 2767.815 uV 16:33:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.437 uVs 16:33:53 Integrated Voltage Measurement... 16:34:02 Voltage Offset Correction: v_off_ini = 2772.370 uV, v_off_fin = 2791.877 uV 16:34:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.364 uVs 16:34:02 Integrated Voltage Measurement... 16:34:11 Voltage Offset Correction: v_off_ini = 2782.601 uV, v_off_fin = 2762.290 uV 16:34:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.846 uVs 16:34:11 Integrated Voltage Measurement... 16:34:20 Voltage Offset Correction: v_off_ini = 2782.398 uV, v_off_fin = 2788.864 uV 16:34:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.849 uVs 16:34:22 I2Y Average and RMS of Measurements VT = -187.833 +- 7.091 uVs I2Y = -17.281 +- 0.652 uTm^2 16:34:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:34:31 Integrated Voltage Measurement... 16:34:40 Voltage Offset Correction: v_off_ini = 2753.760 uV, v_off_fin = 2760.525 uV 16:34:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.248 uVs 16:34:40 Integrated Voltage Measurement... 16:34:49 Voltage Offset Correction: v_off_ini = 2757.513 uV, v_off_fin = 2754.654 uV 16:34:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.446 uVs 16:34:49 Integrated Voltage Measurement... 16:34:58 Voltage Offset Correction: v_off_ini = 2763.438 uV, v_off_fin = 2776.807 uV 16:34:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.275 uVs 16:34:58 Integrated Voltage Measurement... 16:35:07 Voltage Offset Correction: v_off_ini = 2770.368 uV, v_off_fin = 2770.385 uV 16:35:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 130.929 uVs 16:35:07 Integrated Voltage Measurement... 16:35:16 Voltage Offset Correction: v_off_ini = 2771.807 uV, v_off_fin = 2762.725 uV 16:35:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.758 uVs 16:35:16 Integrated Voltage Measurement... 16:35:25 Voltage Offset Correction: v_off_ini = 2763.960 uV, v_off_fin = 2764.160 uV 16:35:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 125.452 uVs 16:35:29 I1X Average and RMS of Measurements VT = -128.852 +- 4.593 uVs I1X = 25.771 +- 0.919 uTm 16:35:32 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:35:36 Integrated Voltage Measurement... 16:35:45 Voltage Offset Correction: v_off_ini = 2781.883 uV, v_off_fin = 2771.527 uV 16:35:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -210.188 uVs 16:35:45 Integrated Voltage Measurement... 16:35:54 Voltage Offset Correction: v_off_ini = 2758.714 uV, v_off_fin = 2780.241 uV 16:35:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.206 uVs 16:35:54 Integrated Voltage Measurement... 16:36:03 Voltage Offset Correction: v_off_ini = 2772.917 uV, v_off_fin = 2751.495 uV 16:36:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -203.279 uVs 16:36:03 Integrated Voltage Measurement... 16:36:12 Voltage Offset Correction: v_off_ini = 2757.541 uV, v_off_fin = 2770.197 uV 16:36:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.792 uVs 16:36:12 Integrated Voltage Measurement... 16:36:21 Voltage Offset Correction: v_off_ini = 2759.357 uV, v_off_fin = 2755.934 uV 16:36:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.627 uVs 16:36:21 Integrated Voltage Measurement... 16:36:30 Voltage Offset Correction: v_off_ini = 2759.157 uV, v_off_fin = 2767.484 uV 16:36:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.576 uVs 16:36:34 I1Y Average and RMS of Measurements VT = -204.278 +- 1.500 uVs I1Y = -40.856 +- 0.301 uTm 16:36:39 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:36:42 Integrated Voltage Measurement... 16:36:51 Voltage Offset Correction: v_off_ini = 2749.238 uV, v_off_fin = 2758.246 uV 16:36:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -99.164 uVs 16:36:51 Integrated Voltage Measurement... 16:37:00 Voltage Offset Correction: v_off_ini = 2762.529 uV, v_off_fin = 2773.192 uV 16:37:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.816 uVs 16:37:00 Integrated Voltage Measurement... 16:37:09 Voltage Offset Correction: v_off_ini = 2749.597 uV, v_off_fin = 2744.469 uV 16:37:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -106.270 uVs 16:37:09 Integrated Voltage Measurement... 16:37:18 Voltage Offset Correction: v_off_ini = 2736.610 uV, v_off_fin = 2768.568 uV 16:37:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 111.211 uVs 16:37:18 Integrated Voltage Measurement... 16:37:27 Voltage Offset Correction: v_off_ini = 2788.043 uV, v_off_fin = 2748.589 uV 16:37:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -107.808 uVs 16:37:27 Integrated Voltage Measurement... 16:37:36 Voltage Offset Correction: v_off_ini = 2770.434 uV, v_off_fin = 2776.057 uV 16:37:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.825 uVs 16:37:38 I2X Average and RMS of Measurements VT = -95.349 +- 17.253 uVs I2X = 8.772 +- 1.587 uTm^2 16:37:44 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 16:37:46 Integrated Voltage Measurement... 16:37:55 Voltage Offset Correction: v_off_ini = 2786.646 uV, v_off_fin = 2797.847 uV 16:37:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.220 uVs 16:37:55 Integrated Voltage Measurement... 16:38:04 Voltage Offset Correction: v_off_ini = 2776.601 uV, v_off_fin = 2793.192 uV 16:38:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 205.990 uVs 16:38:04 Integrated Voltage Measurement... 16:38:13 Voltage Offset Correction: v_off_ini = 2791.251 uV, v_off_fin = 2791.065 uV 16:38:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.124 uVs 16:38:13 Integrated Voltage Measurement... 16:38:22 Voltage Offset Correction: v_off_ini = 2810.985 uV, v_off_fin = 2826.647 uV 16:38:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.362 uVs 16:38:22 Integrated Voltage Measurement... 16:38:31 Voltage Offset Correction: v_off_ini = 2802.875 uV, v_off_fin = 2792.269 uV 16:38:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -197.033 uVs 16:38:31 Integrated Voltage Measurement... 16:38:40 Voltage Offset Correction: v_off_ini = 2780.089 uV, v_off_fin = 2798.823 uV 16:38:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.988 uVs 16:38:43 I2Y Average and RMS of Measurements VT = -191.453 +- 6.523 uVs I2Y = -17.614 +- 0.600 uTm^2 16:38:47 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:38:52 Integrated Voltage Measurement... 16:39:00 Voltage Offset Correction: v_off_ini = 2762.654 uV, v_off_fin = 2761.418 uV 16:39:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -123.645 uVs 16:39:01 Integrated Voltage Measurement... 16:39:09 Voltage Offset Correction: v_off_ini = 2771.838 uV, v_off_fin = 2785.777 uV 16:39:09 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 133.646 uVs 16:39:10 Integrated Voltage Measurement... 16:39:18 Voltage Offset Correction: v_off_ini = 2769.758 uV, v_off_fin = 2758.464 uV 16:39:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -127.369 uVs 16:39:19 Integrated Voltage Measurement... 16:39:27 Voltage Offset Correction: v_off_ini = 2764.688 uV, v_off_fin = 2763.295 uV 16:39:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 137.379 uVs 16:39:28 Integrated Voltage Measurement... 16:39:37 Voltage Offset Correction: v_off_ini = 2769.147 uV, v_off_fin = 2772.580 uV 16:39:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -138.379 uVs 16:39:37 Integrated Voltage Measurement... 16:39:46 Voltage Offset Correction: v_off_ini = 2761.945 uV, v_off_fin = 2789.383 uV 16:39:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.120 uVs 16:39:50 I1X Average and RMS of Measurements VT = -134.590 +- 5.967 uVs I1X = 26.919 +- 1.193 uTm 16:39:52 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:39:56 Integrated Voltage Measurement... 16:40:05 Voltage Offset Correction: v_off_ini = 2803.595 uV, v_off_fin = 2778.724 uV 16:40:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.703 uVs 16:40:05 Integrated Voltage Measurement... 16:40:14 Voltage Offset Correction: v_off_ini = 2780.528 uV, v_off_fin = 2790.616 uV 16:40:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.175 uVs 16:40:14 Integrated Voltage Measurement... 16:40:23 Voltage Offset Correction: v_off_ini = 2778.444 uV, v_off_fin = 2764.921 uV 16:40:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.345 uVs 16:40:23 Integrated Voltage Measurement... 16:40:32 Voltage Offset Correction: v_off_ini = 2780.534 uV, v_off_fin = 2786.427 uV 16:40:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 205.598 uVs 16:40:32 Integrated Voltage Measurement... 16:40:41 Voltage Offset Correction: v_off_ini = 2769.707 uV, v_off_fin = 2745.738 uV 16:40:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.271 uVs 16:40:41 Integrated Voltage Measurement... 16:40:50 Voltage Offset Correction: v_off_ini = 2765.366 uV, v_off_fin = 2780.256 uV 16:40:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.811 uVs 16:40:55 I1Y Average and RMS of Measurements VT = -204.650 +- 5.691 uVs I1Y = -40.930 +- 1.138 uTm 16:41:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:41:02 Integrated Voltage Measurement... 16:41:11 Voltage Offset Correction: v_off_ini = 2766.593 uV, v_off_fin = 2769.299 uV 16:41:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.583 uVs 16:41:11 Integrated Voltage Measurement... 16:41:20 Voltage Offset Correction: v_off_ini = 2737.672 uV, v_off_fin = 2753.404 uV 16:41:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.336 uVs 16:41:20 Integrated Voltage Measurement... 16:41:29 Voltage Offset Correction: v_off_ini = 2727.916 uV, v_off_fin = 2745.799 uV 16:41:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.420 uVs 16:41:29 Integrated Voltage Measurement... 16:41:38 Voltage Offset Correction: v_off_ini = 2756.762 uV, v_off_fin = 2756.672 uV 16:41:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.417 uVs 16:41:38 Integrated Voltage Measurement... 16:41:47 Voltage Offset Correction: v_off_ini = 2749.814 uV, v_off_fin = 2760.700 uV 16:41:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -95.300 uVs 16:41:47 Integrated Voltage Measurement... 16:41:56 Voltage Offset Correction: v_off_ini = 2755.788 uV, v_off_fin = 2768.575 uV 16:41:56 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 85.373 uVs 16:41:59 I2X Average and RMS of Measurements VT = -82.238 +- 6.157 uVs I2X = 7.566 +- 0.567 uTm^2 16:42:04 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 16:42:06 Integrated Voltage Measurement... 16:42:15 Voltage Offset Correction: v_off_ini = 2747.617 uV, v_off_fin = 2766.160 uV 16:42:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -193.103 uVs 16:42:15 Integrated Voltage Measurement... 16:42:24 Voltage Offset Correction: v_off_ini = 2751.998 uV, v_off_fin = 2749.726 uV 16:42:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 178.886 uVs 16:42:25 Integrated Voltage Measurement... 16:42:33 Voltage Offset Correction: v_off_ini = 2772.504 uV, v_off_fin = 2752.661 uV 16:42:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.095 uVs 16:42:34 Integrated Voltage Measurement... 16:42:43 Voltage Offset Correction: v_off_ini = 2776.335 uV, v_off_fin = 2763.593 uV 16:42:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.854 uVs 16:42:43 Integrated Voltage Measurement... 16:42:52 Voltage Offset Correction: v_off_ini = 2778.898 uV, v_off_fin = 2784.110 uV 16:42:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.606 uVs 16:42:52 Integrated Voltage Measurement... 16:43:01 Voltage Offset Correction: v_off_ini = 2770.894 uV, v_off_fin = 2776.979 uV 16:43:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 190.792 uVs 16:43:03 I2Y Average and RMS of Measurements VT = -193.056 +- 9.842 uVs I2Y = -17.761 +- 0.905 uTm^2 16:43:11 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:43:15 Integrated Voltage Measurement... 16:43:24 Voltage Offset Correction: v_off_ini = 2748.877 uV, v_off_fin = 2751.748 uV 16:43:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -137.480 uVs 16:43:24 Integrated Voltage Measurement... 16:43:33 Voltage Offset Correction: v_off_ini = 2776.434 uV, v_off_fin = 2745.582 uV 16:43:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.195 uVs 16:43:33 Integrated Voltage Measurement... 16:43:42 Voltage Offset Correction: v_off_ini = 2765.077 uV, v_off_fin = 2755.118 uV 16:43:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -147.177 uVs 16:43:42 Integrated Voltage Measurement... 16:43:51 Voltage Offset Correction: v_off_ini = 2756.393 uV, v_off_fin = 2734.006 uV 16:43:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.711 uVs 16:43:51 Integrated Voltage Measurement... 16:44:00 Voltage Offset Correction: v_off_ini = 2758.436 uV, v_off_fin = 2757.507 uV 16:44:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -125.754 uVs 16:44:00 Integrated Voltage Measurement... 16:44:09 Voltage Offset Correction: v_off_ini = 2766.087 uV, v_off_fin = 2786.905 uV 16:44:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.948 uVs 16:44:13 I1X Average and RMS of Measurements VT = -135.711 +- 10.437 uVs I1X = 27.143 +- 2.088 uTm 16:44:16 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:44:20 Integrated Voltage Measurement... 16:44:29 Voltage Offset Correction: v_off_ini = 2774.998 uV, v_off_fin = 2756.411 uV 16:44:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.129 uVs 16:44:29 Integrated Voltage Measurement... 16:44:38 Voltage Offset Correction: v_off_ini = 2770.933 uV, v_off_fin = 2792.989 uV 16:44:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.928 uVs 16:44:38 Integrated Voltage Measurement... 16:44:47 Voltage Offset Correction: v_off_ini = 2764.327 uV, v_off_fin = 2774.707 uV 16:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.249 uVs 16:44:47 Integrated Voltage Measurement... 16:44:56 Voltage Offset Correction: v_off_ini = 2784.576 uV, v_off_fin = 2782.679 uV 16:44:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.321 uVs 16:44:56 Integrated Voltage Measurement... 16:45:05 Voltage Offset Correction: v_off_ini = 2781.038 uV, v_off_fin = 2763.278 uV 16:45:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.180 uVs 16:45:05 Integrated Voltage Measurement... 16:45:14 Voltage Offset Correction: v_off_ini = 2770.406 uV, v_off_fin = 2771.420 uV 16:45:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.521 uVs 16:45:18 I1Y Average and RMS of Measurements VT = -198.555 +- 1.370 uVs I1Y = -39.712 +- 0.273 uTm 16:45:20 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:45:23 Integrated Voltage Measurement... 16:45:32 Voltage Offset Correction: v_off_ini = 2775.503 uV, v_off_fin = 2784.587 uV 16:45:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -93.419 uVs 16:45:32 Integrated Voltage Measurement... 16:45:41 Voltage Offset Correction: v_off_ini = 2775.215 uV, v_off_fin = 2777.164 uV 16:45:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 115.883 uVs 16:45:41 Integrated Voltage Measurement... 16:45:50 Voltage Offset Correction: v_off_ini = 2766.299 uV, v_off_fin = 2761.475 uV 16:45:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -115.336 uVs 16:45:50 Integrated Voltage Measurement... 16:45:59 Voltage Offset Correction: v_off_ini = 2768.264 uV, v_off_fin = 2778.067 uV 16:45:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 134.109 uVs 16:45:59 Integrated Voltage Measurement... 16:46:08 Voltage Offset Correction: v_off_ini = 2809.742 uV, v_off_fin = 2768.903 uV 16:46:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.760 uVs 16:46:08 Integrated Voltage Measurement... 16:46:17 Voltage Offset Correction: v_off_ini = 2820.941 uV, v_off_fin = 2824.174 uV 16:46:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 93.842 uVs 16:46:20 I2X Average and RMS of Measurements VT = -109.558 +- 10.943 uVs I2X = 10.079 +- 1.007 uTm^2 16:46:22 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 16:46:25 Integrated Voltage Measurement... 16:46:34 Voltage Offset Correction: v_off_ini = 2794.566 uV, v_off_fin = 2793.956 uV 16:46:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -185.403 uVs 16:46:34 Integrated Voltage Measurement... 16:46:43 Voltage Offset Correction: v_off_ini = 2806.038 uV, v_off_fin = 2804.024 uV 16:46:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 206.213 uVs 16:46:43 Integrated Voltage Measurement... 16:46:52 Voltage Offset Correction: v_off_ini = 2804.201 uV, v_off_fin = 2799.258 uV 16:46:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.497 uVs 16:46:52 Integrated Voltage Measurement... 16:47:01 Voltage Offset Correction: v_off_ini = 2801.292 uV, v_off_fin = 2797.496 uV 16:47:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.203 uVs 16:47:01 Integrated Voltage Measurement... 16:47:10 Voltage Offset Correction: v_off_ini = 2766.105 uV, v_off_fin = 2790.438 uV 16:47:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.653 uVs 16:47:10 Integrated Voltage Measurement... 16:47:19 Voltage Offset Correction: v_off_ini = 2805.060 uV, v_off_fin = 2810.892 uV 16:47:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 204.007 uVs 16:47:21 I2Y Average and RMS of Measurements VT = -195.996 +- 3.889 uVs I2Y = -18.032 +- 0.358 uTm^2 16:47:25 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:47:30 Integrated Voltage Measurement... 16:47:39 Voltage Offset Correction: v_off_ini = 2762.651 uV, v_off_fin = 2769.225 uV 16:47:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -131.244 uVs 16:47:39 Integrated Voltage Measurement... 16:47:48 Voltage Offset Correction: v_off_ini = 2775.798 uV, v_off_fin = 2753.031 uV 16:47:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 147.142 uVs 16:47:48 Integrated Voltage Measurement... 16:47:57 Voltage Offset Correction: v_off_ini = 2775.828 uV, v_off_fin = 2785.474 uV 16:47:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.124 uVs 16:47:57 Integrated Voltage Measurement... 16:48:06 Voltage Offset Correction: v_off_ini = 2796.550 uV, v_off_fin = 2785.123 uV 16:48:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 162.116 uVs 16:48:06 Integrated Voltage Measurement... 16:48:15 Voltage Offset Correction: v_off_ini = 2773.137 uV, v_off_fin = 2753.261 uV 16:48:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -126.378 uVs 16:48:15 Integrated Voltage Measurement... 16:48:24 Voltage Offset Correction: v_off_ini = 2748.801 uV, v_off_fin = 2768.276 uV 16:48:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 132.143 uVs 16:48:28 I1X Average and RMS of Measurements VT = -137.191 +- 5.833 uVs I1X = 27.439 +- 1.167 uTm 16:48:30 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:48:35 Integrated Voltage Measurement... 16:48:43 Voltage Offset Correction: v_off_ini = 2786.988 uV, v_off_fin = 2776.901 uV 16:48:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -203.255 uVs 16:48:43 Integrated Voltage Measurement... 16:48:52 Voltage Offset Correction: v_off_ini = 2787.138 uV, v_off_fin = 2806.966 uV 16:48:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.006 uVs 16:48:52 Integrated Voltage Measurement... 16:49:01 Voltage Offset Correction: v_off_ini = 2802.330 uV, v_off_fin = 2783.090 uV 16:49:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.694 uVs 16:49:01 Integrated Voltage Measurement... 16:49:10 Voltage Offset Correction: v_off_ini = 2784.781 uV, v_off_fin = 2782.896 uV 16:49:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.748 uVs 16:49:10 Integrated Voltage Measurement... 16:49:19 Voltage Offset Correction: v_off_ini = 2786.181 uV, v_off_fin = 2782.327 uV 16:49:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.341 uVs 16:49:19 Integrated Voltage Measurement... 16:49:28 Voltage Offset Correction: v_off_ini = 2765.738 uV, v_off_fin = 2785.314 uV 16:49:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.636 uVs 16:49:33 I1Y Average and RMS of Measurements VT = -207.280 +- 4.347 uVs I1Y = -41.457 +- 0.870 uTm 16:49:35 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:49:38 Integrated Voltage Measurement... 16:49:47 Voltage Offset Correction: v_off_ini = 2789.251 uV, v_off_fin = 2814.854 uV 16:49:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -112.727 uVs 16:49:47 Integrated Voltage Measurement... 16:49:56 Voltage Offset Correction: v_off_ini = 2805.819 uV, v_off_fin = 2813.419 uV 16:49:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 128.700 uVs 16:49:56 Integrated Voltage Measurement... 16:50:05 Voltage Offset Correction: v_off_ini = 2803.209 uV, v_off_fin = 2790.160 uV 16:50:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -87.099 uVs 16:50:05 Integrated Voltage Measurement... 16:50:14 Voltage Offset Correction: v_off_ini = 2794.149 uV, v_off_fin = 2812.144 uV 16:50:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.545 uVs 16:50:14 Integrated Voltage Measurement... 16:50:23 Voltage Offset Correction: v_off_ini = 2803.223 uV, v_off_fin = 2791.893 uV 16:50:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -98.969 uVs 16:50:23 Integrated Voltage Measurement... 16:50:32 Voltage Offset Correction: v_off_ini = 2805.463 uV, v_off_fin = 2803.726 uV 16:50:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.240 uVs 16:50:34 I2X Average and RMS of Measurements VT = -102.713 +- 13.119 uVs I2X = 9.450 +- 1.207 uTm^2 16:50:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 16:50:39 Integrated Voltage Measurement... 16:50:48 Voltage Offset Correction: v_off_ini = 2824.126 uV, v_off_fin = 2840.686 uV 16:50:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.824 uVs 16:50:48 Integrated Voltage Measurement... 16:50:57 Voltage Offset Correction: v_off_ini = 2837.797 uV, v_off_fin = 2831.193 uV 16:50:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.940 uVs 16:50:57 Integrated Voltage Measurement... 16:51:06 Voltage Offset Correction: v_off_ini = 2809.421 uV, v_off_fin = 2829.139 uV 16:51:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -196.889 uVs 16:51:06 Integrated Voltage Measurement... 16:51:15 Voltage Offset Correction: v_off_ini = 2819.390 uV, v_off_fin = 2817.684 uV 16:51:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.636 uVs 16:51:16 Integrated Voltage Measurement... 16:51:25 Voltage Offset Correction: v_off_ini = 2807.630 uV, v_off_fin = 2807.354 uV 16:51:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.795 uVs 16:51:25 Integrated Voltage Measurement... 16:51:34 Voltage Offset Correction: v_off_ini = 2817.972 uV, v_off_fin = 2811.274 uV 16:51:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.949 uVs 16:51:36 I2Y Average and RMS of Measurements VT = -192.505 +- 8.061 uVs I2Y = -17.710 +- 0.742 uTm^2 16:51:40 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:51:44 Integrated Voltage Measurement... 16:51:53 Voltage Offset Correction: v_off_ini = 2814.783 uV, v_off_fin = 2797.172 uV 16:51:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -165.068 uVs 16:51:53 Integrated Voltage Measurement... 16:52:02 Voltage Offset Correction: v_off_ini = 2795.760 uV, v_off_fin = 2811.116 uV 16:52:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 138.851 uVs 16:52:02 Integrated Voltage Measurement... 16:52:11 Voltage Offset Correction: v_off_ini = 2785.252 uV, v_off_fin = 2785.938 uV 16:52:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -124.509 uVs 16:52:11 Integrated Voltage Measurement... 16:52:20 Voltage Offset Correction: v_off_ini = 2777.948 uV, v_off_fin = 2770.451 uV 16:52:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 131.323 uVs 16:52:20 Integrated Voltage Measurement... 16:52:29 Voltage Offset Correction: v_off_ini = 2759.803 uV, v_off_fin = 2759.430 uV 16:52:29 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -136.910 uVs 16:52:29 Integrated Voltage Measurement... 16:52:38 Voltage Offset Correction: v_off_ini = 2764.266 uV, v_off_fin = 2770.645 uV 16:52:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 120.668 uVs 16:52:42 I1X Average and RMS of Measurements VT = -136.221 +- 11.134 uVs I1X = 27.246 +- 2.229 uTm 16:52:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:52:49 Integrated Voltage Measurement... 16:52:58 Voltage Offset Correction: v_off_ini = 2746.359 uV, v_off_fin = 2769.610 uV 16:52:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -202.675 uVs 16:52:58 Integrated Voltage Measurement... 16:53:07 Voltage Offset Correction: v_off_ini = 2766.777 uV, v_off_fin = 2761.583 uV 16:53:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.466 uVs 16:53:07 Integrated Voltage Measurement... 16:53:16 Voltage Offset Correction: v_off_ini = 2773.856 uV, v_off_fin = 2773.026 uV 16:53:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.699 uVs 16:53:16 Integrated Voltage Measurement... 16:53:25 Voltage Offset Correction: v_off_ini = 2767.348 uV, v_off_fin = 2790.016 uV 16:53:25 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.490 uVs 16:53:25 Integrated Voltage Measurement... 16:53:34 Voltage Offset Correction: v_off_ini = 2804.156 uV, v_off_fin = 2782.821 uV 16:53:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.275 uVs 16:53:34 Integrated Voltage Measurement... 16:53:43 Voltage Offset Correction: v_off_ini = 2792.029 uV, v_off_fin = 2813.882 uV 16:53:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 200.602 uVs 16:53:47 I1Y Average and RMS of Measurements VT = -197.868 +- 11.550 uVs I1Y = -39.574 +- 2.309 uTm 16:53:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:53:52 Integrated Voltage Measurement... 16:54:01 Voltage Offset Correction: v_off_ini = 2776.972 uV, v_off_fin = 2762.571 uV 16:54:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -94.381 uVs 16:54:01 Integrated Voltage Measurement... 16:54:10 Voltage Offset Correction: v_off_ini = 2805.382 uV, v_off_fin = 2818.299 uV 16:54:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 108.951 uVs 16:54:10 Integrated Voltage Measurement... 16:54:19 Voltage Offset Correction: v_off_ini = 2829.126 uV, v_off_fin = 2804.868 uV 16:54:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.892 uVs 16:54:19 Integrated Voltage Measurement... 16:54:28 Voltage Offset Correction: v_off_ini = 2822.578 uV, v_off_fin = 2834.277 uV 16:54:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 116.735 uVs 16:54:28 Integrated Voltage Measurement... 16:54:37 Voltage Offset Correction: v_off_ini = 2835.429 uV, v_off_fin = 2822.062 uV 16:54:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -97.202 uVs 16:54:37 Integrated Voltage Measurement... 16:54:46 Voltage Offset Correction: v_off_ini = 2829.026 uV, v_off_fin = 2845.248 uV 16:54:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 90.988 uVs 16:54:49 I2X Average and RMS of Measurements VT = -99.025 +- 3.489 uVs I2X = 9.111 +- 0.321 uTm^2 16:54:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 16:54:54 Integrated Voltage Measurement... 16:55:03 Voltage Offset Correction: v_off_ini = 2837.957 uV, v_off_fin = 2834.805 uV 16:55:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.688 uVs 16:55:03 Integrated Voltage Measurement... 16:55:12 Voltage Offset Correction: v_off_ini = 2847.715 uV, v_off_fin = 2838.678 uV 16:55:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 172.870 uVs 16:55:12 Integrated Voltage Measurement... 16:55:21 Voltage Offset Correction: v_off_ini = 2856.333 uV, v_off_fin = 2837.652 uV 16:55:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.596 uVs 16:55:21 Integrated Voltage Measurement... 16:55:30 Voltage Offset Correction: v_off_ini = 2841.301 uV, v_off_fin = 2839.896 uV 16:55:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.188 uVs 16:55:30 Integrated Voltage Measurement... 16:55:39 Voltage Offset Correction: v_off_ini = 2843.474 uV, v_off_fin = 2849.868 uV 16:55:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -160.083 uVs 16:55:39 Integrated Voltage Measurement... 16:55:48 Voltage Offset Correction: v_off_ini = 2854.482 uV, v_off_fin = 2852.956 uV 16:55:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 176.659 uVs 16:55:50 I2Y Average and RMS of Measurements VT = -178.514 +- 11.371 uVs I2Y = -16.423 +- 1.046 uTm^2 16:55:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:55:59 Integrated Voltage Measurement... 16:56:08 Voltage Offset Correction: v_off_ini = 2845.610 uV, v_off_fin = 2854.374 uV 16:56:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -140.753 uVs 16:56:08 Integrated Voltage Measurement... 16:56:17 Voltage Offset Correction: v_off_ini = 2846.431 uV, v_off_fin = 2858.293 uV 16:56:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 123.511 uVs 16:56:17 Integrated Voltage Measurement... 16:56:26 Voltage Offset Correction: v_off_ini = 2859.172 uV, v_off_fin = 2876.383 uV 16:56:26 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -141.115 uVs 16:56:26 Integrated Voltage Measurement... 16:56:35 Voltage Offset Correction: v_off_ini = 2878.284 uV, v_off_fin = 2880.236 uV 16:56:35 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.4999 mm dXY = 0.4998 mm VT = 139.456 uVs 16:56:35 Integrated Voltage Measurement... 16:56:44 Voltage Offset Correction: v_off_ini = 2874.436 uV, v_off_fin = 2884.235 uV 16:56:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -142.773 uVs 16:56:44 Integrated Voltage Measurement... 16:56:53 Voltage Offset Correction: v_off_ini = 2876.849 uV, v_off_fin = 2892.421 uV 16:56:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.960 uVs 16:56:57 I1X Average and RMS of Measurements VT = -136.095 +- 3.333 uVs I1X = 27.222 +- 0.668 uTm 16:56:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:57:03 Integrated Voltage Measurement... 16:57:12 Voltage Offset Correction: v_off_ini = 2869.589 uV, v_off_fin = 2864.104 uV 16:57:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -193.671 uVs 16:57:12 Integrated Voltage Measurement... 16:57:21 Voltage Offset Correction: v_off_ini = 2870.801 uV, v_off_fin = 2899.881 uV 16:57:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.134 uVs 16:57:21 Integrated Voltage Measurement... 16:57:30 Voltage Offset Correction: v_off_ini = 2892.882 uV, v_off_fin = 2879.261 uV 16:57:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -196.762 uVs 16:57:30 Integrated Voltage Measurement... 16:57:39 Voltage Offset Correction: v_off_ini = 2890.472 uV, v_off_fin = 2886.608 uV 16:57:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.442 uVs 16:57:39 Integrated Voltage Measurement... 16:57:48 Voltage Offset Correction: v_off_ini = 2901.805 uV, v_off_fin = 2892.988 uV 16:57:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -197.679 uVs 16:57:48 Integrated Voltage Measurement... 16:57:57 Voltage Offset Correction: v_off_ini = 2884.172 uV, v_off_fin = 2916.635 uV 16:57:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.881 uVs 16:58:01 I1Y Average and RMS of Measurements VT = -200.761 +- 1.357 uVs I1Y = -40.152 +- 0.269 uTm 16:58:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:58:07 Integrated Voltage Measurement... 16:58:15 Voltage Offset Correction: v_off_ini = 2856.481 uV, v_off_fin = 2847.540 uV 16:58:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.895 uVs 16:58:16 Integrated Voltage Measurement... 16:58:24 Voltage Offset Correction: v_off_ini = 2869.339 uV, v_off_fin = 2860.969 uV 16:58:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 91.112 uVs 16:58:25 Integrated Voltage Measurement... 16:58:34 Voltage Offset Correction: v_off_ini = 2861.354 uV, v_off_fin = 2842.243 uV 16:58:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -110.764 uVs 16:58:34 Integrated Voltage Measurement... 16:58:43 Voltage Offset Correction: v_off_ini = 2849.109 uV, v_off_fin = 2844.971 uV 16:58:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.860 uVs 16:58:43 Integrated Voltage Measurement... 16:58:52 Voltage Offset Correction: v_off_ini = 2856.882 uV, v_off_fin = 2832.495 uV 16:58:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -104.147 uVs 16:58:52 Integrated Voltage Measurement... 16:59:01 Voltage Offset Correction: v_off_ini = 2854.445 uV, v_off_fin = 2861.058 uV 16:59:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 106.745 uVs 16:59:03 I2X Average and RMS of Measurements VT = -99.921 +- 9.910 uVs I2X = 9.193 +- 0.912 uTm^2 16:59:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 16:59:08 Integrated Voltage Measurement... 16:59:17 Voltage Offset Correction: v_off_ini = 2815.930 uV, v_off_fin = 2792.383 uV 16:59:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -180.738 uVs 16:59:17 Integrated Voltage Measurement... 16:59:26 Voltage Offset Correction: v_off_ini = 2782.570 uV, v_off_fin = 2823.941 uV 16:59:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 201.513 uVs 16:59:26 Integrated Voltage Measurement... 16:59:35 Voltage Offset Correction: v_off_ini = 2834.011 uV, v_off_fin = 2812.381 uV 16:59:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.373 uVs 16:59:35 Integrated Voltage Measurement... 16:59:44 Voltage Offset Correction: v_off_ini = 2812.969 uV, v_off_fin = 2798.195 uV 16:59:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.727 uVs 16:59:44 Integrated Voltage Measurement... 16:59:53 Voltage Offset Correction: v_off_ini = 2793.675 uV, v_off_fin = 2789.917 uV 16:59:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.765 uVs 16:59:53 Integrated Voltage Measurement... 17:00:02 Voltage Offset Correction: v_off_ini = 2780.977 uV, v_off_fin = 2755.298 uV 17:00:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.711 uVs 17:00:04 I2Y Average and RMS of Measurements VT = -186.471 +- 3.308 uVs I2Y = -17.155 +- 0.304 uTm^2 17:00:09 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:00:13 Integrated Voltage Measurement... 17:00:22 Voltage Offset Correction: v_off_ini = 2755.301 uV, v_off_fin = 2757.162 uV 17:00:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -127.394 uVs 17:00:22 Integrated Voltage Measurement... 17:00:31 Voltage Offset Correction: v_off_ini = 2740.880 uV, v_off_fin = 2755.390 uV 17:00:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 149.589 uVs 17:00:31 Integrated Voltage Measurement... 17:00:40 Voltage Offset Correction: v_off_ini = 2750.569 uV, v_off_fin = 2777.795 uV 17:00:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -155.986 uVs 17:00:40 Integrated Voltage Measurement... 17:00:49 Voltage Offset Correction: v_off_ini = 2769.167 uV, v_off_fin = 2767.092 uV 17:00:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 144.114 uVs 17:00:49 Integrated Voltage Measurement... 17:00:58 Voltage Offset Correction: v_off_ini = 2778.686 uV, v_off_fin = 2767.657 uV 17:00:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -149.704 uVs 17:00:58 Integrated Voltage Measurement... 17:01:07 Voltage Offset Correction: v_off_ini = 2748.010 uV, v_off_fin = 2789.910 uV 17:01:07 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 135.734 uVs 17:01:11 I1X Average and RMS of Measurements VT = -143.754 +- 4.775 uVs I1X = 28.753 +- 0.956 uTm 17:01:13 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:01:18 Integrated Voltage Measurement... 17:01:27 Voltage Offset Correction: v_off_ini = 2799.247 uV, v_off_fin = 2778.757 uV 17:01:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -178.742 uVs 17:01:27 Integrated Voltage Measurement... 17:01:36 Voltage Offset Correction: v_off_ini = 2778.553 uV, v_off_fin = 2806.365 uV 17:01:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.355 uVs 17:01:36 Integrated Voltage Measurement... 17:01:45 Voltage Offset Correction: v_off_ini = 2811.810 uV, v_off_fin = 2801.057 uV 17:01:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.669 uVs 17:01:45 Integrated Voltage Measurement... 17:01:54 Voltage Offset Correction: v_off_ini = 2788.680 uV, v_off_fin = 2822.672 uV 17:01:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.395 uVs 17:01:54 Integrated Voltage Measurement... 17:02:03 Voltage Offset Correction: v_off_ini = 2800.254 uV, v_off_fin = 2805.809 uV 17:02:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.970 uVs 17:02:03 Integrated Voltage Measurement... 17:02:11 Voltage Offset Correction: v_off_ini = 2787.400 uV, v_off_fin = 2789.427 uV 17:02:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 195.052 uVs 17:02:16 I1Y Average and RMS of Measurements VT = -190.030 +- 6.412 uVs I1Y = -38.007 +- 1.282 uTm 17:02:18 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:02:21 Integrated Voltage Measurement... 17:02:30 Voltage Offset Correction: v_off_ini = 2799.706 uV, v_off_fin = 2812.405 uV 17:02:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.673 uVs 17:02:30 Integrated Voltage Measurement... 17:02:39 Voltage Offset Correction: v_off_ini = 2815.569 uV, v_off_fin = 2833.002 uV 17:02:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 87.552 uVs 17:02:39 Integrated Voltage Measurement... 17:02:48 Voltage Offset Correction: v_off_ini = 2808.986 uV, v_off_fin = 2797.473 uV 17:02:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -125.961 uVs 17:02:48 Integrated Voltage Measurement... 17:02:57 Voltage Offset Correction: v_off_ini = 2812.172 uV, v_off_fin = 2817.370 uV 17:02:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 94.919 uVs 17:02:57 Integrated Voltage Measurement... 17:03:06 Voltage Offset Correction: v_off_ini = 2832.981 uV, v_off_fin = 2833.050 uV 17:03:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -105.624 uVs 17:03:06 Integrated Voltage Measurement... 17:03:15 Voltage Offset Correction: v_off_ini = 2843.344 uV, v_off_fin = 2815.981 uV 17:03:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 95.261 uVs 17:03:17 I2X Average and RMS of Measurements VT = -98.832 +- 10.200 uVs I2X = 9.093 +- 0.938 uTm^2 17:03:20 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:03:22 Integrated Voltage Measurement... 17:03:31 Voltage Offset Correction: v_off_ini = 2805.511 uV, v_off_fin = 2808.053 uV 17:03:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.541 uVs 17:03:31 Integrated Voltage Measurement... 17:03:40 Voltage Offset Correction: v_off_ini = 2800.791 uV, v_off_fin = 2809.402 uV 17:03:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.602 uVs 17:03:40 Integrated Voltage Measurement... 17:03:49 Voltage Offset Correction: v_off_ini = 2802.261 uV, v_off_fin = 2801.510 uV 17:03:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.289 uVs 17:03:49 Integrated Voltage Measurement... 17:03:58 Voltage Offset Correction: v_off_ini = 2802.878 uV, v_off_fin = 2811.000 uV 17:03:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.105 uVs 17:03:58 Integrated Voltage Measurement... 17:04:07 Voltage Offset Correction: v_off_ini = 2837.170 uV, v_off_fin = 2825.211 uV 17:04:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.538 uVs 17:04:07 Integrated Voltage Measurement... 17:04:16 Voltage Offset Correction: v_off_ini = 2859.370 uV, v_off_fin = 2861.092 uV 17:04:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 174.619 uVs 17:04:19 I2Y Average and RMS of Measurements VT = -188.949 +- 6.081 uVs I2Y = -17.383 +- 0.559 uTm^2 17:04:49 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:04:54 Integrated Voltage Measurement... 17:05:02 Voltage Offset Correction: v_off_ini = 2893.208 uV, v_off_fin = 2904.184 uV 17:05:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.625 uVs 17:05:03 Integrated Voltage Measurement... 17:05:11 Voltage Offset Correction: v_off_ini = 2903.731 uV, v_off_fin = 2874.264 uV 17:05:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.774 uVs 17:05:12 Integrated Voltage Measurement... 17:05:20 Voltage Offset Correction: v_off_ini = 2903.986 uV, v_off_fin = 2905.597 uV 17:05:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.117 uVs 17:05:21 Integrated Voltage Measurement... 17:05:29 Voltage Offset Correction: v_off_ini = 2897.333 uV, v_off_fin = 2875.555 uV 17:05:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.444 uVs 17:05:30 Integrated Voltage Measurement... 17:05:38 Voltage Offset Correction: v_off_ini = 2865.939 uV, v_off_fin = 2874.644 uV 17:05:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -79.737 uVs 17:05:39 Integrated Voltage Measurement... 17:05:47 Voltage Offset Correction: v_off_ini = 2871.182 uV, v_off_fin = 2846.466 uV 17:05:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.568 uVs 17:05:52 I1X Average and RMS of Measurements VT = -69.378 +- 2.760 uVs I1X = 13.876 +- 0.552 uTm 17:05:54 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:05:58 Integrated Voltage Measurement... 17:06:07 Voltage Offset Correction: v_off_ini = 2865.846 uV, v_off_fin = 2842.748 uV 17:06:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.378 uVs 17:06:07 Integrated Voltage Measurement... 17:06:16 Voltage Offset Correction: v_off_ini = 2846.750 uV, v_off_fin = 2874.751 uV 17:06:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.662 uVs 17:06:16 Integrated Voltage Measurement... 17:06:25 Voltage Offset Correction: v_off_ini = 2869.500 uV, v_off_fin = 2868.756 uV 17:06:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.324 uVs 17:06:25 Integrated Voltage Measurement... 17:06:34 Voltage Offset Correction: v_off_ini = 2873.878 uV, v_off_fin = 2859.428 uV 17:06:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.336 uVs 17:06:34 Integrated Voltage Measurement... 17:06:43 Voltage Offset Correction: v_off_ini = 2867.692 uV, v_off_fin = 2850.740 uV 17:06:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.210 uVs 17:06:43 Integrated Voltage Measurement... 17:06:52 Voltage Offset Correction: v_off_ini = 2868.889 uV, v_off_fin = 2861.430 uV 17:06:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.293 uVs 17:06:56 I1Y Average and RMS of Measurements VT = -214.867 +- 0.741 uVs I1Y = -42.973 +- 0.148 uTm 17:07:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:07:04 Integrated Voltage Measurement... 17:07:13 Voltage Offset Correction: v_off_ini = 2877.746 uV, v_off_fin = 2866.523 uV 17:07:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -58.201 uVs 17:07:13 Integrated Voltage Measurement... 17:07:22 Voltage Offset Correction: v_off_ini = 2892.147 uV, v_off_fin = 2894.172 uV 17:07:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.908 uVs 17:07:22 Integrated Voltage Measurement... 17:07:31 Voltage Offset Correction: v_off_ini = 2893.409 uV, v_off_fin = 2886.035 uV 17:07:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.518 uVs 17:07:31 Integrated Voltage Measurement... 17:07:40 Voltage Offset Correction: v_off_ini = 2894.282 uV, v_off_fin = 2918.011 uV 17:07:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.512 uVs 17:07:40 Integrated Voltage Measurement... 17:07:49 Voltage Offset Correction: v_off_ini = 2885.249 uV, v_off_fin = 2878.565 uV 17:07:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.476 uVs 17:07:49 Integrated Voltage Measurement... 17:07:58 Voltage Offset Correction: v_off_ini = 2884.432 uV, v_off_fin = 2888.213 uV 17:07:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.306 uVs 17:08:01 I2X Average and RMS of Measurements VT = -53.320 +- 4.584 uVs I2X = 4.905 +- 0.422 uTm^2 17:08:06 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 17:08:08 Integrated Voltage Measurement... 17:08:17 Voltage Offset Correction: v_off_ini = 2862.891 uV, v_off_fin = 2855.215 uV 17:08:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -181.014 uVs 17:08:17 Integrated Voltage Measurement... 17:08:26 Voltage Offset Correction: v_off_ini = 2876.915 uV, v_off_fin = 2889.634 uV 17:08:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.399 uVs 17:08:26 Integrated Voltage Measurement... 17:08:35 Voltage Offset Correction: v_off_ini = 2892.409 uV, v_off_fin = 2885.456 uV 17:08:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.954 uVs 17:08:35 Integrated Voltage Measurement... 17:08:44 Voltage Offset Correction: v_off_ini = 2896.697 uV, v_off_fin = 2899.523 uV 17:08:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 220.500 uVs 17:08:44 Integrated Voltage Measurement... 17:08:53 Voltage Offset Correction: v_off_ini = 2897.628 uV, v_off_fin = 2908.189 uV 17:08:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.964 uVs 17:08:53 Integrated Voltage Measurement... 17:09:02 Voltage Offset Correction: v_off_ini = 2901.779 uV, v_off_fin = 2911.455 uV 17:09:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.852 uVs 17:09:05 I2Y Average and RMS of Measurements VT = -210.947 +- 10.486 uVs I2Y = -19.407 +- 0.965 uTm^2 17:09:09 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:09:14 Integrated Voltage Measurement... 17:09:23 Voltage Offset Correction: v_off_ini = 2916.734 uV, v_off_fin = 2910.733 uV 17:09:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -56.284 uVs 17:09:23 Integrated Voltage Measurement... 17:09:32 Voltage Offset Correction: v_off_ini = 2901.479 uV, v_off_fin = 2919.708 uV 17:09:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 50.384 uVs 17:09:32 Integrated Voltage Measurement... 17:09:41 Voltage Offset Correction: v_off_ini = 2915.684 uV, v_off_fin = 2904.957 uV 17:09:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.290 uVs 17:09:41 Integrated Voltage Measurement... 17:09:49 Voltage Offset Correction: v_off_ini = 2906.967 uV, v_off_fin = 2912.824 uV 17:09:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 63.084 uVs 17:09:50 Integrated Voltage Measurement... 17:09:58 Voltage Offset Correction: v_off_ini = 2921.327 uV, v_off_fin = 2931.129 uV 17:09:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.772 uVs 17:09:59 Integrated Voltage Measurement... 17:10:07 Voltage Offset Correction: v_off_ini = 2933.293 uV, v_off_fin = 2932.549 uV 17:10:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.267 uVs 17:10:12 I1X Average and RMS of Measurements VT = -66.347 +- 12.954 uVs I1X = 13.270 +- 2.590 uTm 17:10:14 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:10:18 Integrated Voltage Measurement... 17:10:27 Voltage Offset Correction: v_off_ini = 2910.469 uV, v_off_fin = 2891.884 uV 17:10:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.861 uVs 17:10:27 Integrated Voltage Measurement... 17:10:36 Voltage Offset Correction: v_off_ini = 2893.886 uV, v_off_fin = 2906.989 uV 17:10:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.140 uVs 17:10:36 Integrated Voltage Measurement... 17:10:45 Voltage Offset Correction: v_off_ini = 2907.479 uV, v_off_fin = 2901.483 uV 17:10:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.523 uVs 17:10:45 Integrated Voltage Measurement... 17:10:54 Voltage Offset Correction: v_off_ini = 2888.890 uV, v_off_fin = 2900.246 uV 17:10:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.870 uVs 17:10:54 Integrated Voltage Measurement... 17:11:03 Voltage Offset Correction: v_off_ini = 2893.584 uV, v_off_fin = 2874.652 uV 17:11:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.726 uVs 17:11:03 Integrated Voltage Measurement... 17:11:12 Voltage Offset Correction: v_off_ini = 2909.721 uV, v_off_fin = 2932.362 uV 17:11:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.063 uVs 17:11:16 I1Y Average and RMS of Measurements VT = -219.031 +- 2.340 uVs I1Y = -43.806 +- 0.468 uTm 17:11:21 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:11:24 Integrated Voltage Measurement... 17:11:33 Voltage Offset Correction: v_off_ini = 2922.131 uV, v_off_fin = 2921.044 uV 17:11:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.483 uVs 17:11:33 Integrated Voltage Measurement... 17:11:42 Voltage Offset Correction: v_off_ini = 2913.670 uV, v_off_fin = 2912.747 uV 17:11:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.792 uVs 17:11:42 Integrated Voltage Measurement... 17:11:51 Voltage Offset Correction: v_off_ini = 2923.692 uV, v_off_fin = 2915.730 uV 17:11:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.547 uVs 17:11:51 Integrated Voltage Measurement... 17:12:00 Voltage Offset Correction: v_off_ini = 2904.833 uV, v_off_fin = 2920.886 uV 17:12:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.051 uVs 17:12:00 Integrated Voltage Measurement... 17:12:09 Voltage Offset Correction: v_off_ini = 2905.013 uV, v_off_fin = 2901.858 uV 17:12:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.731 uVs 17:12:09 Integrated Voltage Measurement... 17:12:18 Voltage Offset Correction: v_off_ini = 2913.469 uV, v_off_fin = 2911.286 uV 17:12:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.833 uVs 17:12:21 I2X Average and RMS of Measurements VT = -55.239 +- 4.077 uVs I2X = 5.082 +- 0.375 uTm^2 17:12:26 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 17:12:28 Integrated Voltage Measurement... 17:12:37 Voltage Offset Correction: v_off_ini = 2917.228 uV, v_off_fin = 2910.259 uV 17:12:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.666 uVs 17:12:37 Integrated Voltage Measurement... 17:12:46 Voltage Offset Correction: v_off_ini = 2915.963 uV, v_off_fin = 2920.372 uV 17:12:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 212.371 uVs 17:12:46 Integrated Voltage Measurement... 17:12:55 Voltage Offset Correction: v_off_ini = 2901.678 uV, v_off_fin = 2905.696 uV 17:12:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.439 uVs 17:12:55 Integrated Voltage Measurement... 17:13:04 Voltage Offset Correction: v_off_ini = 2907.270 uV, v_off_fin = 2891.772 uV 17:13:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.282 uVs 17:13:04 Integrated Voltage Measurement... 17:13:13 Voltage Offset Correction: v_off_ini = 2893.628 uV, v_off_fin = 2887.210 uV 17:13:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.226 uVs 17:13:13 Integrated Voltage Measurement... 17:13:22 Voltage Offset Correction: v_off_ini = 2881.212 uV, v_off_fin = 2900.742 uV 17:13:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.981 uVs 17:13:25 I2Y Average and RMS of Measurements VT = -217.994 +- 3.152 uVs I2Y = -20.055 +- 0.290 uTm^2 17:13:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:13:34 Integrated Voltage Measurement... 17:13:42 Voltage Offset Correction: v_off_ini = 2913.798 uV, v_off_fin = 2906.386 uV 17:13:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -84.958 uVs 17:13:43 Integrated Voltage Measurement... 17:13:51 Voltage Offset Correction: v_off_ini = 2926.328 uV, v_off_fin = 2918.496 uV 17:13:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 63.192 uVs 17:13:52 Integrated Voltage Measurement... 17:14:00 Voltage Offset Correction: v_off_ini = 2906.952 uV, v_off_fin = 2904.004 uV 17:14:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.838 uVs 17:14:01 Integrated Voltage Measurement... 17:14:09 Voltage Offset Correction: v_off_ini = 2919.764 uV, v_off_fin = 2900.055 uV 17:14:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.200 uVs 17:14:10 Integrated Voltage Measurement... 17:14:18 Voltage Offset Correction: v_off_ini = 2899.096 uV, v_off_fin = 2916.827 uV 17:14:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.133 uVs 17:14:19 Integrated Voltage Measurement... 17:14:27 Voltage Offset Correction: v_off_ini = 2914.130 uV, v_off_fin = 2910.336 uV 17:14:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.800 uVs 17:14:32 I1X Average and RMS of Measurements VT = -65.687 +- 6.266 uVs I1X = 13.138 +- 1.254 uTm 17:14:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:14:38 Integrated Voltage Measurement... 17:14:47 Voltage Offset Correction: v_off_ini = 2931.975 uV, v_off_fin = 2928.473 uV 17:14:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -202.130 uVs 17:14:47 Integrated Voltage Measurement... 17:14:56 Voltage Offset Correction: v_off_ini = 2915.473 uV, v_off_fin = 2934.178 uV 17:14:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.035 uVs 17:14:56 Integrated Voltage Measurement... 17:15:05 Voltage Offset Correction: v_off_ini = 2920.268 uV, v_off_fin = 2905.905 uV 17:15:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -200.133 uVs 17:15:05 Integrated Voltage Measurement... 17:15:14 Voltage Offset Correction: v_off_ini = 2915.053 uV, v_off_fin = 2939.033 uV 17:15:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.992 uVs 17:15:14 Integrated Voltage Measurement... 17:15:23 Voltage Offset Correction: v_off_ini = 2920.434 uV, v_off_fin = 2906.654 uV 17:15:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -205.369 uVs 17:15:23 Integrated Voltage Measurement... 17:15:32 Voltage Offset Correction: v_off_ini = 2931.952 uV, v_off_fin = 2930.019 uV 17:15:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 216.516 uVs 17:15:36 I1Y Average and RMS of Measurements VT = -203.362 +- 5.423 uVs I1Y = -40.673 +- 1.084 uTm 17:15:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:15:44 Integrated Voltage Measurement... 17:15:53 Voltage Offset Correction: v_off_ini = 2909.255 uV, v_off_fin = 2905.185 uV 17:15:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -65.264 uVs 17:15:53 Integrated Voltage Measurement... 17:16:02 Voltage Offset Correction: v_off_ini = 2916.426 uV, v_off_fin = 2926.622 uV 17:16:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.291 uVs 17:16:02 Integrated Voltage Measurement... 17:16:11 Voltage Offset Correction: v_off_ini = 2909.946 uV, v_off_fin = 2932.132 uV 17:16:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.534 uVs 17:16:11 Integrated Voltage Measurement... 17:16:20 Voltage Offset Correction: v_off_ini = 2918.779 uV, v_off_fin = 2913.477 uV 17:16:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.977 uVs 17:16:20 Integrated Voltage Measurement... 17:16:29 Voltage Offset Correction: v_off_ini = 2896.912 uV, v_off_fin = 2871.409 uV 17:16:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.705 uVs 17:16:29 Integrated Voltage Measurement... 17:16:38 Voltage Offset Correction: v_off_ini = 2903.741 uV, v_off_fin = 2901.366 uV 17:16:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.142 uVs 17:16:40 I2X Average and RMS of Measurements VT = -47.485 +- 1.964 uVs I2X = 4.369 +- 0.181 uTm^2 17:16:45 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:16:48 Integrated Voltage Measurement... 17:16:57 Voltage Offset Correction: v_off_ini = 2922.311 uV, v_off_fin = 2902.014 uV 17:16:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.368 uVs 17:16:57 Integrated Voltage Measurement... 17:17:06 Voltage Offset Correction: v_off_ini = 2906.849 uV, v_off_fin = 2891.919 uV 17:17:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.293 uVs 17:17:06 Integrated Voltage Measurement... 17:17:15 Voltage Offset Correction: v_off_ini = 2899.655 uV, v_off_fin = 2893.392 uV 17:17:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -218.299 uVs 17:17:15 Integrated Voltage Measurement... 17:17:24 Voltage Offset Correction: v_off_ini = 2908.685 uV, v_off_fin = 2897.417 uV 17:17:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.789 uVs 17:17:24 Integrated Voltage Measurement... 17:17:33 Voltage Offset Correction: v_off_ini = 2866.467 uV, v_off_fin = 2892.284 uV 17:17:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.395 uVs 17:17:33 Integrated Voltage Measurement... 17:17:42 Voltage Offset Correction: v_off_ini = 2903.002 uV, v_off_fin = 2901.940 uV 17:17:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.307 uVs 17:17:45 I2Y Average and RMS of Measurements VT = -206.075 +- 10.222 uVs I2Y = -18.959 +- 0.940 uTm^2 17:17:49 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:17:53 Integrated Voltage Measurement... 17:18:02 Voltage Offset Correction: v_off_ini = 2917.311 uV, v_off_fin = 2915.059 uV 17:18:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -56.503 uVs 17:18:02 Integrated Voltage Measurement... 17:18:11 Voltage Offset Correction: v_off_ini = 2916.042 uV, v_off_fin = 2911.131 uV 17:18:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.891 uVs 17:18:11 Integrated Voltage Measurement... 17:18:20 Voltage Offset Correction: v_off_ini = 2919.378 uV, v_off_fin = 2905.278 uV 17:18:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.865 uVs 17:18:20 Integrated Voltage Measurement... 17:18:29 Voltage Offset Correction: v_off_ini = 2901.655 uV, v_off_fin = 2906.600 uV 17:18:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.149 uVs 17:18:29 Integrated Voltage Measurement... 17:18:38 Voltage Offset Correction: v_off_ini = 2904.027 uV, v_off_fin = 2890.226 uV 17:18:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.465 uVs 17:18:38 Integrated Voltage Measurement... 17:18:47 Voltage Offset Correction: v_off_ini = 2892.499 uV, v_off_fin = 2886.335 uV 17:18:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.458 uVs 17:18:52 I1X Average and RMS of Measurements VT = -59.889 +- 14.300 uVs I1X = 11.978 +- 2.860 uTm 17:18:54 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:18:58 Integrated Voltage Measurement... 17:19:07 Voltage Offset Correction: v_off_ini = 2913.266 uV, v_off_fin = 2892.148 uV 17:19:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -209.947 uVs 17:19:07 Integrated Voltage Measurement... 17:19:16 Voltage Offset Correction: v_off_ini = 2883.380 uV, v_off_fin = 2911.971 uV 17:19:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.542 uVs 17:19:16 Integrated Voltage Measurement... 17:19:25 Voltage Offset Correction: v_off_ini = 2900.003 uV, v_off_fin = 2906.604 uV 17:19:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.007 uVs 17:19:25 Integrated Voltage Measurement... 17:19:34 Voltage Offset Correction: v_off_ini = 2907.098 uV, v_off_fin = 2923.133 uV 17:19:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.770 uVs 17:19:34 Integrated Voltage Measurement... 17:19:43 Voltage Offset Correction: v_off_ini = 2912.675 uV, v_off_fin = 2908.678 uV 17:19:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.933 uVs 17:19:43 Integrated Voltage Measurement... 17:19:52 Voltage Offset Correction: v_off_ini = 2913.086 uV, v_off_fin = 2892.390 uV 17:19:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.050 uVs 17:19:56 I1Y Average and RMS of Measurements VT = -222.041 +- 2.963 uVs I1Y = -44.409 +- 0.593 uTm 17:20:01 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:20:04 Integrated Voltage Measurement... 17:20:13 Voltage Offset Correction: v_off_ini = 2890.421 uV, v_off_fin = 2894.242 uV 17:20:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.952 uVs 17:20:13 Integrated Voltage Measurement... 17:20:22 Voltage Offset Correction: v_off_ini = 2904.181 uV, v_off_fin = 2907.822 uV 17:20:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.701 uVs 17:20:22 Integrated Voltage Measurement... 17:20:31 Voltage Offset Correction: v_off_ini = 2910.719 uV, v_off_fin = 2896.177 uV 17:20:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.554 uVs 17:20:31 Integrated Voltage Measurement... 17:20:40 Voltage Offset Correction: v_off_ini = 2884.246 uV, v_off_fin = 2879.696 uV 17:20:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.299 uVs 17:20:40 Integrated Voltage Measurement... 17:20:49 Voltage Offset Correction: v_off_ini = 2880.459 uV, v_off_fin = 2883.008 uV 17:20:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.758 uVs 17:20:49 Integrated Voltage Measurement... 17:20:58 Voltage Offset Correction: v_off_ini = 2882.023 uV, v_off_fin = 2893.895 uV 17:20:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 1.476 uVs 17:21:00 I2X Average and RMS of Measurements VT = -37.290 +- 11.704 uVs I2X = 3.431 +- 1.077 uTm^2 17:21:05 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 17:21:08 Integrated Voltage Measurement... 17:21:17 Voltage Offset Correction: v_off_ini = 2876.652 uV, v_off_fin = 2885.615 uV 17:21:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.186 uVs 17:21:17 Integrated Voltage Measurement... 17:21:26 Voltage Offset Correction: v_off_ini = 2867.939 uV, v_off_fin = 2858.298 uV 17:21:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.896 uVs 17:21:26 Integrated Voltage Measurement... 17:21:35 Voltage Offset Correction: v_off_ini = 2870.017 uV, v_off_fin = 2851.486 uV 17:21:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.966 uVs 17:21:35 Integrated Voltage Measurement... 17:21:44 Voltage Offset Correction: v_off_ini = 2865.609 uV, v_off_fin = 2868.627 uV 17:21:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 237.560 uVs 17:21:44 Integrated Voltage Measurement... 17:21:53 Voltage Offset Correction: v_off_ini = 2876.608 uV, v_off_fin = 2882.138 uV 17:21:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -209.725 uVs 17:21:53 Integrated Voltage Measurement... 17:22:02 Voltage Offset Correction: v_off_ini = 2892.901 uV, v_off_fin = 2884.651 uV 17:22:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.675 uVs 17:22:04 I2Y Average and RMS of Measurements VT = -216.835 +- 11.050 uVs I2Y = -19.949 +- 1.017 uTm^2 17:22:09 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:22:13 Integrated Voltage Measurement... 17:22:22 Voltage Offset Correction: v_off_ini = 2871.735 uV, v_off_fin = 2862.960 uV 17:22:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.034 uVs 17:22:22 Integrated Voltage Measurement... 17:22:31 Voltage Offset Correction: v_off_ini = 2874.562 uV, v_off_fin = 2892.102 uV 17:22:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 80.440 uVs 17:22:31 Integrated Voltage Measurement... 17:22:40 Voltage Offset Correction: v_off_ini = 2872.051 uV, v_off_fin = 2903.670 uV 17:22:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.125 uVs 17:22:40 Integrated Voltage Measurement... 17:22:49 Voltage Offset Correction: v_off_ini = 2883.042 uV, v_off_fin = 2901.929 uV 17:22:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.754 uVs 17:22:49 Integrated Voltage Measurement... 17:22:58 Voltage Offset Correction: v_off_ini = 2889.863 uV, v_off_fin = 2877.998 uV 17:22:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.305 uVs 17:22:58 Integrated Voltage Measurement... 17:23:07 Voltage Offset Correction: v_off_ini = 2885.706 uV, v_off_fin = 2875.953 uV 17:23:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.264 uVs 17:23:11 I1X Average and RMS of Measurements VT = -69.987 +- 1.660 uVs I1X = 13.997 +- 0.332 uTm 17:23:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:23:18 Integrated Voltage Measurement... 17:23:27 Voltage Offset Correction: v_off_ini = 2881.785 uV, v_off_fin = 2861.013 uV 17:23:27 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = -225.703 uVs 17:23:27 Integrated Voltage Measurement... 17:23:36 Voltage Offset Correction: v_off_ini = 2859.614 uV, v_off_fin = 2847.957 uV 17:23:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.268 uVs 17:23:36 Integrated Voltage Measurement... 17:23:45 Voltage Offset Correction: v_off_ini = 2841.615 uV, v_off_fin = 2860.029 uV 17:23:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -206.861 uVs 17:23:45 Integrated Voltage Measurement... 17:23:54 Voltage Offset Correction: v_off_ini = 2893.935 uV, v_off_fin = 2887.734 uV 17:23:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 221.292 uVs 17:23:54 Integrated Voltage Measurement... 17:24:03 Voltage Offset Correction: v_off_ini = 2878.396 uV, v_off_fin = 2874.522 uV 17:24:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.147 uVs 17:24:03 Integrated Voltage Measurement... 17:24:12 Voltage Offset Correction: v_off_ini = 2857.681 uV, v_off_fin = 2859.772 uV 17:24:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.027 uVs 17:24:16 I1Y Average and RMS of Measurements VT = -215.216 +- 0.988 uVs I1Y = -43.044 +- 0.199 uTm 17:24:21 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:24:24 Integrated Voltage Measurement... 17:24:33 Voltage Offset Correction: v_off_ini = 2870.276 uV, v_off_fin = 2848.029 uV 17:24:33 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.619 uVs 17:24:33 Integrated Voltage Measurement... 17:24:42 Voltage Offset Correction: v_off_ini = 2867.898 uV, v_off_fin = 2876.359 uV 17:24:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.078 uVs 17:24:42 Integrated Voltage Measurement... 17:24:51 Voltage Offset Correction: v_off_ini = 2867.033 uV, v_off_fin = 2835.687 uV 17:24:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -39.234 uVs 17:24:51 Integrated Voltage Measurement... 17:25:00 Voltage Offset Correction: v_off_ini = 2847.768 uV, v_off_fin = 2867.364 uV 17:25:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.375 uVs 17:25:00 Integrated Voltage Measurement... 17:25:09 Voltage Offset Correction: v_off_ini = 2868.016 uV, v_off_fin = 2855.280 uV 17:25:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.132 uVs 17:25:09 Integrated Voltage Measurement... 17:25:18 Voltage Offset Correction: v_off_ini = 2849.731 uV, v_off_fin = 2830.740 uV 17:25:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.320 uVs 17:25:20 I2X Average and RMS of Measurements VT = -46.793 +- 2.876 uVs I2X = 4.305 +- 0.265 uTm^2 17:25:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 17:25:28 Integrated Voltage Measurement... 17:25:37 Voltage Offset Correction: v_off_ini = 2816.516 uV, v_off_fin = 2823.545 uV 17:25:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -195.393 uVs 17:25:37 Integrated Voltage Measurement... 17:25:46 Voltage Offset Correction: v_off_ini = 2835.561 uV, v_off_fin = 2844.044 uV 17:25:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.067 uVs 17:25:46 Integrated Voltage Measurement... 17:25:55 Voltage Offset Correction: v_off_ini = 2858.216 uV, v_off_fin = 2855.881 uV 17:25:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.591 uVs 17:25:55 Integrated Voltage Measurement... 17:26:04 Voltage Offset Correction: v_off_ini = 2868.603 uV, v_off_fin = 2862.124 uV 17:26:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.875 uVs 17:26:04 Integrated Voltage Measurement... 17:26:13 Voltage Offset Correction: v_off_ini = 2843.435 uV, v_off_fin = 2825.636 uV 17:26:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -194.890 uVs 17:26:13 Integrated Voltage Measurement... 17:26:22 Voltage Offset Correction: v_off_ini = 2843.835 uV, v_off_fin = 2849.027 uV 17:26:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.116 uVs 17:26:24 I2Y Average and RMS of Measurements VT = -216.155 +- 4.704 uVs I2Y = -19.886 +- 0.433 uTm^2 17:26:32 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:26:36 Integrated Voltage Measurement... 17:26:45 Voltage Offset Correction: v_off_ini = 2808.132 uV, v_off_fin = 2812.276 uV 17:26:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.054 uVs 17:26:45 Integrated Voltage Measurement... 17:26:54 Voltage Offset Correction: v_off_ini = 2790.390 uV, v_off_fin = 2809.704 uV 17:26:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.046 uVs 17:26:54 Integrated Voltage Measurement... 17:27:03 Voltage Offset Correction: v_off_ini = 2808.168 uV, v_off_fin = 2830.283 uV 17:27:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.536 uVs 17:27:03 Integrated Voltage Measurement... 17:27:12 Voltage Offset Correction: v_off_ini = 2820.180 uV, v_off_fin = 2836.525 uV 17:27:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.097 uVs 17:27:12 Integrated Voltage Measurement... 17:27:21 Voltage Offset Correction: v_off_ini = 2804.771 uV, v_off_fin = 2824.312 uV 17:27:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.230 uVs 17:27:21 Integrated Voltage Measurement... 17:27:30 Voltage Offset Correction: v_off_ini = 2844.360 uV, v_off_fin = 2845.470 uV 17:27:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.321 uVs 17:27:34 I1X Average and RMS of Measurements VT = -64.880 +- 20.060 uVs I1X = 12.976 +- 4.012 uTm 17:27:37 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:27:41 Integrated Voltage Measurement... 17:27:50 Voltage Offset Correction: v_off_ini = 2830.266 uV, v_off_fin = 2835.248 uV 17:27:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.357 uVs 17:27:50 Integrated Voltage Measurement... 17:27:59 Voltage Offset Correction: v_off_ini = 2860.987 uV, v_off_fin = 2847.248 uV 17:27:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.627 uVs 17:27:59 Integrated Voltage Measurement... 17:28:08 Voltage Offset Correction: v_off_ini = 2832.536 uV, v_off_fin = 2823.067 uV 17:28:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.841 uVs 17:28:08 Integrated Voltage Measurement... 17:28:17 Voltage Offset Correction: v_off_ini = 2831.274 uV, v_off_fin = 2843.648 uV 17:28:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 207.811 uVs 17:28:17 Integrated Voltage Measurement... 17:28:26 Voltage Offset Correction: v_off_ini = 2829.992 uV, v_off_fin = 2805.870 uV 17:28:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.015 uVs 17:28:26 Integrated Voltage Measurement... 17:28:35 Voltage Offset Correction: v_off_ini = 2813.072 uV, v_off_fin = 2821.334 uV 17:28:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.589 uVs 17:28:39 I1Y Average and RMS of Measurements VT = -217.373 +- 3.273 uVs I1Y = -43.475 +- 0.655 uTm 17:28:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:28:44 Integrated Voltage Measurement... 17:28:53 Voltage Offset Correction: v_off_ini = 2829.585 uV, v_off_fin = 2808.855 uV 17:28:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.247 uVs 17:28:53 Integrated Voltage Measurement... 17:29:02 Voltage Offset Correction: v_off_ini = 2819.377 uV, v_off_fin = 2815.240 uV 17:29:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.677 uVs 17:29:02 Integrated Voltage Measurement... 17:29:11 Voltage Offset Correction: v_off_ini = 2819.447 uV, v_off_fin = 2820.884 uV 17:29:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.122 uVs 17:29:11 Integrated Voltage Measurement... 17:29:20 Voltage Offset Correction: v_off_ini = 2815.310 uV, v_off_fin = 2862.272 uV 17:29:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 81.627 uVs 17:29:20 Integrated Voltage Measurement... 17:29:29 Voltage Offset Correction: v_off_ini = 2851.619 uV, v_off_fin = 2861.580 uV 17:29:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.238 uVs 17:29:29 Integrated Voltage Measurement... 17:29:38 Voltage Offset Correction: v_off_ini = 2861.628 uV, v_off_fin = 2854.390 uV 17:29:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.010 uVs 17:29:41 I2X Average and RMS of Measurements VT = -50.820 +- 15.717 uVs I2X = 4.675 +- 1.446 uTm^2 17:29:43 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 17:29:46 Integrated Voltage Measurement... 17:29:55 Voltage Offset Correction: v_off_ini = 2837.136 uV, v_off_fin = 2837.903 uV 17:29:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.119 uVs 17:29:55 Integrated Voltage Measurement... 17:30:04 Voltage Offset Correction: v_off_ini = 2843.213 uV, v_off_fin = 2837.749 uV 17:30:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.266 uVs 17:30:04 Integrated Voltage Measurement... 17:30:13 Voltage Offset Correction: v_off_ini = 2847.771 uV, v_off_fin = 2841.988 uV 17:30:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.895 uVs 17:30:13 Integrated Voltage Measurement... 17:30:22 Voltage Offset Correction: v_off_ini = 2847.043 uV, v_off_fin = 2862.785 uV 17:30:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 210.113 uVs 17:30:22 Integrated Voltage Measurement... 17:30:31 Voltage Offset Correction: v_off_ini = 2829.898 uV, v_off_fin = 2829.072 uV 17:30:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -239.907 uVs 17:30:31 Integrated Voltage Measurement... 17:30:40 Voltage Offset Correction: v_off_ini = 2840.982 uV, v_off_fin = 2848.363 uV 17:30:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 228.958 uVs 17:30:42 I2Y Average and RMS of Measurements VT = -217.543 +- 12.176 uVs I2Y = -20.014 +- 1.120 uTm^2 17:30:46 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:30:50 Integrated Voltage Measurement... 17:30:59 Voltage Offset Correction: v_off_ini = 2852.433 uV, v_off_fin = 2856.328 uV 17:30:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -75.578 uVs 17:30:59 Integrated Voltage Measurement... 17:31:08 Voltage Offset Correction: v_off_ini = 2856.752 uV, v_off_fin = 2860.405 uV 17:31:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.485 uVs 17:31:08 Integrated Voltage Measurement... 17:31:17 Voltage Offset Correction: v_off_ini = 2848.489 uV, v_off_fin = 2838.849 uV 17:31:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.023 uVs 17:31:17 Integrated Voltage Measurement... 17:31:26 Voltage Offset Correction: v_off_ini = 2829.869 uV, v_off_fin = 2839.026 uV 17:31:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.871 uVs 17:31:26 Integrated Voltage Measurement... 17:31:35 Voltage Offset Correction: v_off_ini = 2861.510 uV, v_off_fin = 2859.784 uV 17:31:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.063 uVs 17:31:35 Integrated Voltage Measurement... 17:31:44 Voltage Offset Correction: v_off_ini = 2851.395 uV, v_off_fin = 2835.110 uV 17:31:44 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.344 uVs 17:31:49 I1X Average and RMS of Measurements VT = -68.561 +- 1.884 uVs I1X = 13.713 +- 0.377 uTm 17:31:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:31:55 Integrated Voltage Measurement... 17:32:04 Voltage Offset Correction: v_off_ini = 2813.838 uV, v_off_fin = 2815.189 uV 17:32:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.734 uVs 17:32:04 Integrated Voltage Measurement... 17:32:13 Voltage Offset Correction: v_off_ini = 2826.124 uV, v_off_fin = 2827.685 uV 17:32:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.502 uVs 17:32:13 Integrated Voltage Measurement... 17:32:22 Voltage Offset Correction: v_off_ini = 2837.181 uV, v_off_fin = 2835.724 uV 17:32:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.617 uVs 17:32:22 Integrated Voltage Measurement... 17:32:31 Voltage Offset Correction: v_off_ini = 2833.005 uV, v_off_fin = 2863.328 uV 17:32:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.247 uVs 17:32:31 Integrated Voltage Measurement... 17:32:40 Voltage Offset Correction: v_off_ini = 2838.437 uV, v_off_fin = 2831.843 uV 17:32:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.256 uVs 17:32:40 Integrated Voltage Measurement... 17:32:49 Voltage Offset Correction: v_off_ini = 2856.714 uV, v_off_fin = 2858.535 uV 17:32:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 212.052 uVs 17:32:53 I1Y Average and RMS of Measurements VT = -212.235 +- 5.371 uVs I1Y = -42.447 +- 1.074 uTm 17:32:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:32:58 Integrated Voltage Measurement... 17:33:07 Voltage Offset Correction: v_off_ini = 2841.975 uV, v_off_fin = 2834.437 uV 17:33:07 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -19.175 uVs 17:33:07 Integrated Voltage Measurement... 17:33:16 Voltage Offset Correction: v_off_ini = 2872.676 uV, v_off_fin = 2876.872 uV 17:33:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.518 uVs 17:33:16 Integrated Voltage Measurement... 17:33:25 Voltage Offset Correction: v_off_ini = 2848.835 uV, v_off_fin = 2842.987 uV 17:33:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.625 uVs 17:33:25 Integrated Voltage Measurement... 17:33:34 Voltage Offset Correction: v_off_ini = 2852.262 uV, v_off_fin = 2846.289 uV 17:33:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.050 uVs 17:33:34 Integrated Voltage Measurement... 17:33:43 Voltage Offset Correction: v_off_ini = 2859.576 uV, v_off_fin = 2842.012 uV 17:33:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.559 uVs 17:33:43 Integrated Voltage Measurement... 17:33:52 Voltage Offset Correction: v_off_ini = 2842.657 uV, v_off_fin = 2849.482 uV 17:33:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 65.058 uVs 17:33:55 I2X Average and RMS of Measurements VT = -45.997 +- 8.561 uVs I2X = 4.232 +- 0.788 uTm^2 17:33:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 17:34:00 Integrated Voltage Measurement... 17:34:09 Voltage Offset Correction: v_off_ini = 2864.925 uV, v_off_fin = 2852.056 uV 17:34:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.397 uVs 17:34:09 Integrated Voltage Measurement... 17:34:18 Voltage Offset Correction: v_off_ini = 2876.734 uV, v_off_fin = 2881.501 uV 17:34:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 225.405 uVs 17:34:18 Integrated Voltage Measurement... 17:34:27 Voltage Offset Correction: v_off_ini = 2867.840 uV, v_off_fin = 2860.362 uV 17:34:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.360 uVs 17:34:27 Integrated Voltage Measurement... 17:34:36 Voltage Offset Correction: v_off_ini = 2839.622 uV, v_off_fin = 2836.824 uV 17:34:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.965 uVs 17:34:36 Integrated Voltage Measurement... 17:34:45 Voltage Offset Correction: v_off_ini = 2850.312 uV, v_off_fin = 2846.617 uV 17:34:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.298 uVs 17:34:45 Integrated Voltage Measurement... 17:34:54 Voltage Offset Correction: v_off_ini = 2843.122 uV, v_off_fin = 2836.941 uV 17:34:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.705 uVs 17:34:56 I2Y Average and RMS of Measurements VT = -213.355 +- 4.408 uVs I2Y = -19.629 +- 0.406 uTm^2 17:35:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:35:05 Integrated Voltage Measurement... 17:35:14 Voltage Offset Correction: v_off_ini = 2835.094 uV, v_off_fin = 2826.356 uV 17:35:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -77.441 uVs 17:35:14 Integrated Voltage Measurement... 17:35:23 Voltage Offset Correction: v_off_ini = 2836.735 uV, v_off_fin = 2813.557 uV 17:35:23 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.861 uVs 17:35:23 Integrated Voltage Measurement... 17:35:32 Voltage Offset Correction: v_off_ini = 2838.996 uV, v_off_fin = 2830.724 uV 17:35:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -68.440 uVs 17:35:32 Integrated Voltage Measurement... 17:35:41 Voltage Offset Correction: v_off_ini = 2815.988 uV, v_off_fin = 2828.849 uV 17:35:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.331 uVs 17:35:41 Integrated Voltage Measurement... 17:35:50 Voltage Offset Correction: v_off_ini = 2824.251 uV, v_off_fin = 2810.051 uV 17:35:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -71.730 uVs 17:35:50 Integrated Voltage Measurement... 17:35:59 Voltage Offset Correction: v_off_ini = 2807.434 uV, v_off_fin = 2811.527 uV 17:35:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.398 uVs 17:36:03 I1X Average and RMS of Measurements VT = -66.034 +- 3.675 uVs I1X = 13.208 +- 0.734 uTm 17:36:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:36:09 Integrated Voltage Measurement... 17:36:18 Voltage Offset Correction: v_off_ini = 2825.562 uV, v_off_fin = 2810.855 uV 17:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.099 uVs 17:36:18 Integrated Voltage Measurement... 17:36:27 Voltage Offset Correction: v_off_ini = 2812.423 uV, v_off_fin = 2830.102 uV 17:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.265 uVs 17:36:27 Integrated Voltage Measurement... 17:36:36 Voltage Offset Correction: v_off_ini = 2849.960 uV, v_off_fin = 2821.062 uV 17:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.890 uVs 17:36:36 Integrated Voltage Measurement... 17:36:45 Voltage Offset Correction: v_off_ini = 2806.168 uV, v_off_fin = 2833.632 uV 17:36:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.080 uVs 17:36:45 Integrated Voltage Measurement... 17:36:54 Voltage Offset Correction: v_off_ini = 2797.313 uV, v_off_fin = 2789.097 uV 17:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.950 uVs 17:36:54 Integrated Voltage Measurement... 17:37:03 Voltage Offset Correction: v_off_ini = 2818.176 uV, v_off_fin = 2817.808 uV 17:37:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.985 uVs 17:37:08 I1Y Average and RMS of Measurements VT = -207.711 +- 4.055 uVs I1Y = -41.542 +- 0.811 uTm 17:37:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:37:13 Integrated Voltage Measurement... 17:37:22 Voltage Offset Correction: v_off_ini = 2809.207 uV, v_off_fin = 2786.447 uV 17:37:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.228 uVs 17:37:22 Integrated Voltage Measurement... 17:37:31 Voltage Offset Correction: v_off_ini = 2828.122 uV, v_off_fin = 2816.057 uV 17:37:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.499 uVs 17:37:31 Integrated Voltage Measurement... 17:37:40 Voltage Offset Correction: v_off_ini = 2796.932 uV, v_off_fin = 2811.388 uV 17:37:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.475 uVs 17:37:40 Integrated Voltage Measurement... 17:37:49 Voltage Offset Correction: v_off_ini = 2811.905 uV, v_off_fin = 2814.390 uV 17:37:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.475 uVs 17:37:49 Integrated Voltage Measurement... 17:37:58 Voltage Offset Correction: v_off_ini = 2808.830 uV, v_off_fin = 2798.737 uV 17:37:58 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -46.950 uVs 17:37:58 Integrated Voltage Measurement... 17:38:07 Voltage Offset Correction: v_off_ini = 2791.846 uV, v_off_fin = 2801.602 uV 17:38:07 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 52.692 uVs 17:38:09 I2X Average and RMS of Measurements VT = -55.886 +- 4.448 uVs I2X = 5.142 +- 0.409 uTm^2 17:38:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 17:38:14 Integrated Voltage Measurement... 17:38:23 Voltage Offset Correction: v_off_ini = 2794.636 uV, v_off_fin = 2786.565 uV 17:38:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -212.939 uVs 17:38:23 Integrated Voltage Measurement... 17:38:32 Voltage Offset Correction: v_off_ini = 2822.530 uV, v_off_fin = 2810.036 uV 17:38:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.448 uVs 17:38:32 Integrated Voltage Measurement... 17:38:41 Voltage Offset Correction: v_off_ini = 2847.862 uV, v_off_fin = 2830.431 uV 17:38:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.710 uVs 17:38:41 Integrated Voltage Measurement... 17:38:50 Voltage Offset Correction: v_off_ini = 2835.052 uV, v_off_fin = 2854.679 uV 17:38:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.611 uVs 17:38:50 Integrated Voltage Measurement... 17:38:59 Voltage Offset Correction: v_off_ini = 2837.673 uV, v_off_fin = 2868.892 uV 17:38:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.772 uVs 17:38:59 Integrated Voltage Measurement... 17:39:08 Voltage Offset Correction: v_off_ini = 2828.349 uV, v_off_fin = 2835.673 uV 17:39:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.944 uVs 17:39:11 I2Y Average and RMS of Measurements VT = -210.737 +- 2.979 uVs I2Y = -19.388 +- 0.274 uTm^2 17:39:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:39:19 Integrated Voltage Measurement... 17:39:28 Voltage Offset Correction: v_off_ini = 2829.248 uV, v_off_fin = 2848.615 uV 17:39:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -23.328 uVs 17:39:28 Integrated Voltage Measurement... 17:39:37 Voltage Offset Correction: v_off_ini = 2842.913 uV, v_off_fin = 2821.134 uV 17:39:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.918 uVs 17:39:37 Integrated Voltage Measurement... 17:39:46 Voltage Offset Correction: v_off_ini = 2826.641 uV, v_off_fin = 2810.953 uV 17:39:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -65.090 uVs 17:39:46 Integrated Voltage Measurement... 17:39:55 Voltage Offset Correction: v_off_ini = 2819.317 uV, v_off_fin = 2825.141 uV 17:39:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 112.487 uVs 17:39:55 Integrated Voltage Measurement... 17:40:04 Voltage Offset Correction: v_off_ini = 2789.891 uV, v_off_fin = 2800.995 uV 17:40:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.602 uVs 17:40:04 Integrated Voltage Measurement... 17:40:13 Voltage Offset Correction: v_off_ini = 2776.567 uV, v_off_fin = 2809.665 uV 17:40:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.730 uVs 17:40:17 I1X Average and RMS of Measurements VT = -66.526 +- 17.295 uVs I1X = 13.306 +- 3.459 uTm 17:40:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:40:24 Integrated Voltage Measurement... 17:40:33 Voltage Offset Correction: v_off_ini = 2794.613 uV, v_off_fin = 2791.371 uV 17:40:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -208.275 uVs 17:40:33 Integrated Voltage Measurement... 17:40:42 Voltage Offset Correction: v_off_ini = 2817.786 uV, v_off_fin = 2824.169 uV 17:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 207.088 uVs 17:40:42 Integrated Voltage Measurement... 17:40:51 Voltage Offset Correction: v_off_ini = 2797.278 uV, v_off_fin = 2800.934 uV 17:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.070 uVs 17:40:51 Integrated Voltage Measurement... 17:41:00 Voltage Offset Correction: v_off_ini = 2812.224 uV, v_off_fin = 2829.604 uV 17:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 204.744 uVs 17:41:00 Integrated Voltage Measurement... 17:41:08 Voltage Offset Correction: v_off_ini = 2817.506 uV, v_off_fin = 2816.659 uV 17:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.047 uVs 17:41:09 Integrated Voltage Measurement... 17:41:17 Voltage Offset Correction: v_off_ini = 2807.778 uV, v_off_fin = 2813.297 uV 17:41:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 217.677 uVs 17:41:22 I1Y Average and RMS of Measurements VT = -209.483 +- 5.044 uVs I1Y = -41.895 +- 1.010 uTm 17:41:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:41:27 Integrated Voltage Measurement... 17:41:36 Voltage Offset Correction: v_off_ini = 2794.610 uV, v_off_fin = 2788.190 uV 17:41:36 Integrated Voltage Measurement dXYus = -1.0002 mm, dXYds = 0.0000 mm dXY = -1.0002 mm VT = -52.641 uVs 17:41:36 Integrated Voltage Measurement... 17:41:45 Voltage Offset Correction: v_off_ini = 2791.153 uV, v_off_fin = 2795.979 uV 17:41:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.841 uVs 17:41:45 Integrated Voltage Measurement... 17:41:54 Voltage Offset Correction: v_off_ini = 2806.938 uV, v_off_fin = 2763.329 uV 17:41:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.953 uVs 17:41:54 Integrated Voltage Measurement... 17:42:03 Voltage Offset Correction: v_off_ini = 2787.427 uV, v_off_fin = 2798.713 uV 17:42:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.788 uVs 17:42:03 Integrated Voltage Measurement... 17:42:12 Voltage Offset Correction: v_off_ini = 2789.630 uV, v_off_fin = 2783.872 uV 17:42:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -80.216 uVs 17:42:12 Integrated Voltage Measurement... 17:42:21 Voltage Offset Correction: v_off_ini = 2786.152 uV, v_off_fin = 2789.502 uV 17:42:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 59.793 uVs 17:42:23 I2X Average and RMS of Measurements VT = -59.205 +- 10.283 uVs I2X = 5.447 +- 0.946 uTm^2 17:42:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 17:42:28 Integrated Voltage Measurement... 17:42:37 Voltage Offset Correction: v_off_ini = 2809.609 uV, v_off_fin = 2786.561 uV 17:42:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -211.515 uVs 17:42:37 Integrated Voltage Measurement... 17:42:46 Voltage Offset Correction: v_off_ini = 2780.013 uV, v_off_fin = 2807.561 uV 17:42:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.451 uVs 17:42:46 Integrated Voltage Measurement... 17:42:55 Voltage Offset Correction: v_off_ini = 2792.248 uV, v_off_fin = 2779.384 uV 17:42:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -169.430 uVs 17:42:55 Integrated Voltage Measurement... 17:43:04 Voltage Offset Correction: v_off_ini = 2805.862 uV, v_off_fin = 2813.546 uV 17:43:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 196.340 uVs 17:43:04 Integrated Voltage Measurement... 17:43:13 Voltage Offset Correction: v_off_ini = 2803.398 uV, v_off_fin = 2803.326 uV 17:43:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.093 uVs 17:43:13 Integrated Voltage Measurement... 17:43:22 Voltage Offset Correction: v_off_ini = 2793.541 uV, v_off_fin = 2798.647 uV 17:43:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.686 uVs 17:43:25 I2Y Average and RMS of Measurements VT = -201.752 +- 16.176 uVs I2Y = -18.561 +- 1.488 uTm^2 17:43:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:43:33 Integrated Voltage Measurement... 17:43:42 Voltage Offset Correction: v_off_ini = 2781.263 uV, v_off_fin = 2761.143 uV 17:43:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -43.915 uVs 17:43:42 Integrated Voltage Measurement... 17:43:51 Voltage Offset Correction: v_off_ini = 2783.208 uV, v_off_fin = 2804.997 uV 17:43:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.258 uVs 17:43:51 Integrated Voltage Measurement... 17:44:00 Voltage Offset Correction: v_off_ini = 2799.067 uV, v_off_fin = 2799.787 uV 17:44:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.866 uVs 17:44:00 Integrated Voltage Measurement... 17:44:09 Voltage Offset Correction: v_off_ini = 2788.028 uV, v_off_fin = 2802.080 uV 17:44:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.281 uVs 17:44:09 Integrated Voltage Measurement... 17:44:18 Voltage Offset Correction: v_off_ini = 2767.741 uV, v_off_fin = 2757.111 uV 17:44:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.324 uVs 17:44:18 Integrated Voltage Measurement... 17:44:27 Voltage Offset Correction: v_off_ini = 2784.132 uV, v_off_fin = 2792.004 uV 17:44:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.313 uVs 17:44:31 I1X Average and RMS of Measurements VT = -62.159 +- 4.397 uVs I1X = 12.432 +- 0.879 uTm 17:44:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:44:38 Integrated Voltage Measurement... 17:44:47 Voltage Offset Correction: v_off_ini = 2776.796 uV, v_off_fin = 2744.760 uV 17:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -204.045 uVs 17:44:47 Integrated Voltage Measurement... 17:44:56 Voltage Offset Correction: v_off_ini = 2761.611 uV, v_off_fin = 2767.939 uV 17:44:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 214.031 uVs 17:44:56 Integrated Voltage Measurement... 17:45:05 Voltage Offset Correction: v_off_ini = 2776.691 uV, v_off_fin = 2762.070 uV 17:45:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -169.282 uVs 17:45:05 Integrated Voltage Measurement... 17:45:14 Voltage Offset Correction: v_off_ini = 2779.855 uV, v_off_fin = 2781.805 uV 17:45:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 201.226 uVs 17:45:14 Integrated Voltage Measurement... 17:45:23 Voltage Offset Correction: v_off_ini = 2762.287 uV, v_off_fin = 2756.498 uV 17:45:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -183.675 uVs 17:45:23 Integrated Voltage Measurement... 17:45:32 Voltage Offset Correction: v_off_ini = 2742.339 uV, v_off_fin = 2747.512 uV 17:45:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 217.999 uVs 17:45:36 I1Y Average and RMS of Measurements VT = -198.376 +- 9.864 uVs I1Y = -39.671 +- 1.973 uTm 17:45:38 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:45:41 Integrated Voltage Measurement... 17:45:50 Voltage Offset Correction: v_off_ini = 2755.710 uV, v_off_fin = 2718.700 uV 17:45:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.101 uVs 17:45:50 Integrated Voltage Measurement... 17:45:59 Voltage Offset Correction: v_off_ini = 2729.233 uV, v_off_fin = 2739.819 uV 17:45:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.840 uVs 17:45:59 Integrated Voltage Measurement... 17:46:08 Voltage Offset Correction: v_off_ini = 2736.329 uV, v_off_fin = 2742.413 uV 17:46:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.641 uVs 17:46:08 Integrated Voltage Measurement... 17:46:17 Voltage Offset Correction: v_off_ini = 2760.566 uV, v_off_fin = 2764.420 uV 17:46:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.110 uVs 17:46:17 Integrated Voltage Measurement... 17:46:26 Voltage Offset Correction: v_off_ini = 2762.280 uV, v_off_fin = 2751.918 uV 17:46:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.190 uVs 17:46:26 Integrated Voltage Measurement... 17:46:35 Voltage Offset Correction: v_off_ini = 2753.963 uV, v_off_fin = 2772.475 uV 17:46:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 71.933 uVs 17:46:37 I2X Average and RMS of Measurements VT = -56.636 +- 3.161 uVs I2X = 5.211 +- 0.291 uTm^2 17:46:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 17:46:42 Integrated Voltage Measurement... 17:46:51 Voltage Offset Correction: v_off_ini = 2766.493 uV, v_off_fin = 2753.501 uV 17:46:51 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -199.033 uVs 17:46:51 Integrated Voltage Measurement... 17:47:00 Voltage Offset Correction: v_off_ini = 2788.228 uV, v_off_fin = 2766.243 uV 17:47:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.280 uVs 17:47:00 Integrated Voltage Measurement... 17:47:09 Voltage Offset Correction: v_off_ini = 2757.425 uV, v_off_fin = 2768.060 uV 17:47:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -220.159 uVs 17:47:10 Integrated Voltage Measurement... 17:47:18 Voltage Offset Correction: v_off_ini = 2751.064 uV, v_off_fin = 2750.249 uV 17:47:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 216.578 uVs 17:47:19 Integrated Voltage Measurement... 17:47:27 Voltage Offset Correction: v_off_ini = 2760.072 uV, v_off_fin = 2764.473 uV 17:47:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -201.557 uVs 17:47:28 Integrated Voltage Measurement... 17:47:37 Voltage Offset Correction: v_off_ini = 2754.932 uV, v_off_fin = 2751.384 uV 17:47:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.972 uVs 17:47:39 I2Y Average and RMS of Measurements VT = -209.430 +- 12.568 uVs I2Y = -19.268 +- 1.156 uTm^2 17:47:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 08:45:59 Wire Position: X0 = 50.0000 mm, Y0 = 0.0000 mm