SLAC Magnetic Measurements Date: 01-06-2022 Time: 09:17:44 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: SXHEPS-000 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched wire2 Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: 09:17:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:17:54 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:17:56 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:17:57 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:17:59 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:21:12 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:21:16 Integrated Voltage Measurement... 09:21:25 Voltage Offset Correction: v_off_ini = 66.785 uV, v_off_fin = 71.799 uV 09:21:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.134 uVs 09:21:25 Integrated Voltage Measurement... 09:21:34 Voltage Offset Correction: v_off_ini = 63.799 uV, v_off_fin = 82.917 uV 09:21:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.561 uVs 09:21:34 Integrated Voltage Measurement... 09:21:43 Voltage Offset Correction: v_off_ini = 67.482 uV, v_off_fin = 67.602 uV 09:21:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.032 uVs 09:21:43 Integrated Voltage Measurement... 09:21:53 Voltage Offset Correction: v_off_ini = 69.721 uV, v_off_fin = 72.461 uV 09:21:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.322 uVs 09:21:53 Integrated Voltage Measurement... 09:22:02 Voltage Offset Correction: v_off_ini = 64.835 uV, v_off_fin = 48.087 uV 09:22:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.572 uVs 09:22:02 Integrated Voltage Measurement... 09:22:11 Voltage Offset Correction: v_off_ini = 46.422 uV, v_off_fin = 62.296 uV 09:22:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.547 uVs 09:22:15 I1X Average and RMS of Measurements VT = -52.861 +- 8.539 uVs I1X = 10.572 +- 1.708 uTm 09:22:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:22:22 Integrated Voltage Measurement... 09:22:31 Voltage Offset Correction: v_off_ini = 51.101 uV, v_off_fin = 49.346 uV 09:22:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -218.959 uVs 09:22:31 Integrated Voltage Measurement... 09:22:40 Voltage Offset Correction: v_off_ini = 63.490 uV, v_off_fin = 83.617 uV 09:22:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 230.202 uVs 09:22:40 Integrated Voltage Measurement... 09:22:49 Voltage Offset Correction: v_off_ini = 54.129 uV, v_off_fin = 52.548 uV 09:22:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.045 uVs 09:22:50 Integrated Voltage Measurement... 09:22:59 Voltage Offset Correction: v_off_ini = 61.866 uV, v_off_fin = 77.974 uV 09:22:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 238.105 uVs 09:22:59 Integrated Voltage Measurement... 09:23:08 Voltage Offset Correction: v_off_ini = 53.975 uV, v_off_fin = 30.838 uV 09:23:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -232.275 uVs 09:23:08 Integrated Voltage Measurement... 09:23:17 Voltage Offset Correction: v_off_ini = 33.721 uV, v_off_fin = 53.208 uV 09:23:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.748 uVs 09:23:21 I1Y Average and RMS of Measurements VT = -231.722 +- 7.456 uVs I1Y = -46.344 +- 1.491 uTm 09:23:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:23:29 Integrated Voltage Measurement... 09:23:39 Voltage Offset Correction: v_off_ini = 16.749 uV, v_off_fin = 38.216 uV 09:23:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.875 uVs 09:23:39 Integrated Voltage Measurement... 09:23:48 Voltage Offset Correction: v_off_ini = 31.628 uV, v_off_fin = 48.811 uV 09:23:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 62.908 uVs 09:23:48 Integrated Voltage Measurement... 09:23:58 Voltage Offset Correction: v_off_ini = 35.247 uV, v_off_fin = 25.639 uV 09:23:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.092 uVs 09:23:58 Integrated Voltage Measurement... 09:24:07 Voltage Offset Correction: v_off_ini = 47.607 uV, v_off_fin = 50.303 uV 09:24:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.261 uVs 09:24:07 Integrated Voltage Measurement... 09:24:17 Voltage Offset Correction: v_off_ini = 49.180 uV, v_off_fin = 44.520 uV 09:24:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -46.137 uVs 09:24:17 Integrated Voltage Measurement... 09:24:26 Voltage Offset Correction: v_off_ini = 52.938 uV, v_off_fin = 48.904 uV 09:24:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.256 uVs 09:24:29 I2X Average and RMS of Measurements VT = -33.588 +- 3.892 uVs I2X = 2.603 +- 0.302 uTm^2 09:24:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:24:37 Integrated Voltage Measurement... 09:24:46 Voltage Offset Correction: v_off_ini = 43.497 uV, v_off_fin = 50.734 uV 09:24:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.823 uVs 09:24:46 Integrated Voltage Measurement... 09:24:56 Voltage Offset Correction: v_off_ini = 46.916 uV, v_off_fin = 47.423 uV 09:24:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.163 uVs 09:24:56 Integrated Voltage Measurement... 09:25:05 Voltage Offset Correction: v_off_ini = 47.806 uV, v_off_fin = 40.411 uV 09:25:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -275.034 uVs 09:25:05 Integrated Voltage Measurement... 09:25:15 Voltage Offset Correction: v_off_ini = 43.753 uV, v_off_fin = 48.168 uV 09:25:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.103 uVs 09:25:15 Integrated Voltage Measurement... 09:25:24 Voltage Offset Correction: v_off_ini = 36.629 uV, v_off_fin = 38.928 uV 09:25:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -223.920 uVs 09:25:24 Integrated Voltage Measurement... 09:25:34 Voltage Offset Correction: v_off_ini = 34.447 uV, v_off_fin = 36.695 uV 09:25:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.190 uVs 09:25:36 I2Y Average and RMS of Measurements VT = -251.372 +- 18.497 uVs I2Y = -19.481 +- 1.434 uTm^2 09:25:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:48:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:48:40 Integrated Voltage Measurement... 09:48:49 Voltage Offset Correction: v_off_ini = -383.967 uV, v_off_fin = -384.570 uV 09:48:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 29.896 uVs 09:48:49 Integrated Voltage Measurement... 09:48:58 Voltage Offset Correction: v_off_ini = -367.750 uV, v_off_fin = -368.454 uV 09:48:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -36.542 uVs 09:48:58 Integrated Voltage Measurement... 09:49:07 Voltage Offset Correction: v_off_ini = -367.971 uV, v_off_fin = -353.008 uV 09:49:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 34.491 uVs 09:49:07 Integrated Voltage Measurement... 09:49:17 Voltage Offset Correction: v_off_ini = -344.084 uV, v_off_fin = -340.387 uV 09:49:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -22.648 uVs 09:49:17 Integrated Voltage Measurement... 09:49:26 Voltage Offset Correction: v_off_ini = -337.251 uV, v_off_fin = -328.687 uV 09:49:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 14.899 uVs 09:49:26 Integrated Voltage Measurement... 09:49:35 Voltage Offset Correction: v_off_ini = -338.075 uV, v_off_fin = -336.757 uV 09:49:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.146 uVs 09:49:39 I1X Average and RMS of Measurements VT = 19.722 +- 15.914 uVs I1X = -3.944 +- 3.183 uTm 09:49:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:49:46 Integrated Voltage Measurement... 09:49:55 Voltage Offset Correction: v_off_ini = -314.128 uV, v_off_fin = -320.382 uV 09:49:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -164.847 uVs 09:49:55 Integrated Voltage Measurement... 09:50:04 Voltage Offset Correction: v_off_ini = -288.028 uV, v_off_fin = -286.401 uV 09:50:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 165.018 uVs 09:50:04 Integrated Voltage Measurement... 09:50:13 Voltage Offset Correction: v_off_ini = -289.955 uV, v_off_fin = -298.547 uV 09:50:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -163.970 uVs 09:50:13 Integrated Voltage Measurement... 09:50:23 Voltage Offset Correction: v_off_ini = -261.862 uV, v_off_fin = -269.752 uV 09:50:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.222 uVs 09:50:23 Integrated Voltage Measurement... 09:50:32 Voltage Offset Correction: v_off_ini = -300.442 uV, v_off_fin = -294.535 uV 09:50:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.788 uVs 09:50:32 Integrated Voltage Measurement... 09:50:41 Voltage Offset Correction: v_off_ini = -282.826 uV, v_off_fin = -266.562 uV 09:50:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 171.765 uVs 09:50:45 I1Y Average and RMS of Measurements VT = -165.268 +- 0.976 uVs I1Y = -33.054 +- 0.195 uTm 09:50:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:50:53 Integrated Voltage Measurement... 09:51:03 Voltage Offset Correction: v_off_ini = -268.612 uV, v_off_fin = -257.995 uV 09:51:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 33.289 uVs 09:51:03 Integrated Voltage Measurement... 09:51:12 Voltage Offset Correction: v_off_ini = -252.628 uV, v_off_fin = -247.861 uV 09:51:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.262 uVs 09:51:12 Integrated Voltage Measurement... 09:51:22 Voltage Offset Correction: v_off_ini = -243.743 uV, v_off_fin = -251.584 uV 09:51:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 22.417 uVs 09:51:22 Integrated Voltage Measurement... 09:51:31 Voltage Offset Correction: v_off_ini = -251.515 uV, v_off_fin = -246.306 uV 09:51:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -14.948 uVs 09:51:31 Integrated Voltage Measurement... 09:51:41 Voltage Offset Correction: v_off_ini = -259.737 uV, v_off_fin = -264.159 uV 09:51:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 39.879 uVs 09:51:41 Integrated Voltage Measurement... 09:51:50 Voltage Offset Correction: v_off_ini = -259.635 uV, v_off_fin = -249.946 uV 09:51:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -13.362 uVs 09:51:53 I2X Average and RMS of Measurements VT = 21.526 +- 3.610 uVs I2X = -1.668 +- 0.280 uTm^2 09:51:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:52:01 Integrated Voltage Measurement... 09:52:10 Voltage Offset Correction: v_off_ini = -250.937 uV, v_off_fin = -249.798 uV 09:52:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.728 uVs 09:52:10 Integrated Voltage Measurement... 09:52:20 Voltage Offset Correction: v_off_ini = -249.287 uV, v_off_fin = -255.894 uV 09:52:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.399 uVs 09:52:20 Integrated Voltage Measurement... 09:52:29 Voltage Offset Correction: v_off_ini = -244.795 uV, v_off_fin = -255.721 uV 09:52:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.187 uVs 09:52:29 Integrated Voltage Measurement... 09:52:39 Voltage Offset Correction: v_off_ini = -255.156 uV, v_off_fin = -234.763 uV 09:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 226.309 uVs 09:52:39 Integrated Voltage Measurement... 09:52:48 Voltage Offset Correction: v_off_ini = -223.558 uV, v_off_fin = -229.580 uV 09:52:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -221.719 uVs 09:52:48 Integrated Voltage Measurement... 09:52:58 Voltage Offset Correction: v_off_ini = -232.486 uV, v_off_fin = -221.609 uV 09:52:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.903 uVs 09:53:00 I2Y Average and RMS of Measurements VT = -211.374 +- 4.468 uVs I2Y = -16.382 +- 0.346 uTm^2 09:53:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:01:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:01:13 Integrated Voltage Measurement... 10:01:22 Voltage Offset Correction: v_off_ini = -248.182 uV, v_off_fin = -252.157 uV 10:01:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -230.458 uVs 10:01:22 Integrated Voltage Measurement... 10:01:31 Voltage Offset Correction: v_off_ini = -277.322 uV, v_off_fin = -276.877 uV 10:01:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 41.572 uVs 10:01:31 Integrated Voltage Measurement... 10:01:40 Voltage Offset Correction: v_off_ini = -278.250 uV, v_off_fin = -289.494 uV 10:01:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.650 uVs 10:01:40 Integrated Voltage Measurement... 10:01:50 Voltage Offset Correction: v_off_ini = -270.269 uV, v_off_fin = -262.430 uV 10:01:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -51.588 uVs 10:01:50 Integrated Voltage Measurement... 10:01:59 Voltage Offset Correction: v_off_ini = -396.976 uV, v_off_fin = -255.410 uV 10:01:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 142.713 uVs 10:01:59 Integrated Voltage Measurement... 10:02:08 Voltage Offset Correction: v_off_ini = -299.976 uV, v_off_fin = -273.232 uV 10:02:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 42.069 uVs 10:02:12 I1X Average and RMS of Measurements VT = -24.908 +- 80.190 uVs I1X = 4.983 +- 16.039 uTm 10:02:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:02:19 Integrated Voltage Measurement... 10:02:28 Voltage Offset Correction: v_off_ini = -281.985 uV, v_off_fin = -269.828 uV 10:02:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -183.328 uVs 10:02:28 Integrated Voltage Measurement... 10:02:37 Voltage Offset Correction: v_off_ini = -261.686 uV, v_off_fin = -173.724 uV 10:02:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 141.503 uVs 10:02:37 Integrated Voltage Measurement... 10:02:46 Voltage Offset Correction: v_off_ini = -216.776 uV, v_off_fin = -309.991 uV 10:02:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -390.734 uVs 10:02:46 Integrated Voltage Measurement... 10:02:56 Voltage Offset Correction: v_off_ini = -247.743 uV, v_off_fin = -233.358 uV 10:02:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 141.739 uVs 10:02:56 Integrated Voltage Measurement... 10:03:05 Voltage Offset Correction: v_off_ini = -218.524 uV, v_off_fin = -255.160 uV 10:03:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.189 uVs 10:03:05 Integrated Voltage Measurement... 10:03:14 Voltage Offset Correction: v_off_ini = -246.804 uV, v_off_fin = -215.407 uV 10:03:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 188.661 uVs 10:03:18 I1Y Average and RMS of Measurements VT = -203.526 +- 45.053 uVs I1Y = -40.706 +- 9.010 uTm 10:03:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:03:26 Integrated Voltage Measurement... 10:03:36 Voltage Offset Correction: v_off_ini = -280.794 uV, v_off_fin = -266.670 uV 10:03:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.622 uVs 10:03:36 Integrated Voltage Measurement... 10:03:45 Voltage Offset Correction: v_off_ini = -237.069 uV, v_off_fin = -229.637 uV 10:03:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.523 uVs 10:03:45 Integrated Voltage Measurement... 10:03:55 Voltage Offset Correction: v_off_ini = -232.587 uV, v_off_fin = -237.848 uV 10:03:55 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -25.265 uVs 10:03:55 Integrated Voltage Measurement... 10:04:04 Voltage Offset Correction: v_off_ini = -250.520 uV, v_off_fin = -235.403 uV 10:04:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.619 uVs 10:04:04 Integrated Voltage Measurement... 10:04:14 Voltage Offset Correction: v_off_ini = -231.204 uV, v_off_fin = -242.050 uV 10:04:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.282 uVs 10:04:14 Integrated Voltage Measurement... 10:04:23 Voltage Offset Correction: v_off_ini = -250.012 uV, v_off_fin = -241.008 uV 10:04:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.648 uVs 10:04:26 I2X Average and RMS of Measurements VT = -20.326 +- 7.958 uVs I2X = 1.575 +- 0.617 uTm^2 10:04:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:04:34 Integrated Voltage Measurement... 10:04:43 Voltage Offset Correction: v_off_ini = -203.708 uV, v_off_fin = -225.531 uV 10:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -233.631 uVs 10:04:43 Integrated Voltage Measurement... 10:04:53 Voltage Offset Correction: v_off_ini = -234.200 uV, v_off_fin = -216.650 uV 10:04:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 214.285 uVs 10:04:53 Integrated Voltage Measurement... 10:05:02 Voltage Offset Correction: v_off_ini = -218.854 uV, v_off_fin = -224.051 uV 10:05:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.431 uVs 10:05:02 Integrated Voltage Measurement... 10:05:12 Voltage Offset Correction: v_off_ini = -226.581 uV, v_off_fin = -212.251 uV 10:05:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.698 uVs 10:05:12 Integrated Voltage Measurement... 10:05:21 Voltage Offset Correction: v_off_ini = -201.698 uV, v_off_fin = -202.286 uV 10:05:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.264 uVs 10:05:21 Integrated Voltage Measurement... 10:05:31 Voltage Offset Correction: v_off_ini = -201.075 uV, v_off_fin = -220.059 uV 10:05:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 189.192 uVs 10:05:33 I2Y Average and RMS of Measurements VT = -207.084 +- 12.034 uVs I2Y = -16.049 +- 0.933 uTm^2 10:05:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:05:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:05:56 Integrated Voltage Measurement... 10:06:05 Voltage Offset Correction: v_off_ini = -226.656 uV, v_off_fin = -219.831 uV 10:06:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -17.238 uVs 10:06:05 Integrated Voltage Measurement... 10:06:14 Voltage Offset Correction: v_off_ini = -212.399 uV, v_off_fin = -201.365 uV 10:06:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.703 uVs 10:06:14 Integrated Voltage Measurement... 10:06:24 Voltage Offset Correction: v_off_ini = -224.057 uV, v_off_fin = -232.952 uV 10:06:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -9.309 uVs 10:06:24 Integrated Voltage Measurement... 10:06:33 Voltage Offset Correction: v_off_ini = -222.457 uV, v_off_fin = -221.657 uV 10:06:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.278 uVs 10:06:33 Integrated Voltage Measurement... 10:06:42 Voltage Offset Correction: v_off_ini = -224.833 uV, v_off_fin = -235.615 uV 10:06:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.549 uVs 10:06:42 Integrated Voltage Measurement... 10:06:51 Voltage Offset Correction: v_off_ini = -252.502 uV, v_off_fin = -237.563 uV 10:06:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.326 uVs 10:06:55 I1X Average and RMS of Measurements VT = -33.400 +- 11.447 uVs I1X = 6.680 +- 2.289 uTm 10:06:58 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:07:02 Integrated Voltage Measurement... 10:07:11 Voltage Offset Correction: v_off_ini = -197.789 uV, v_off_fin = -213.649 uV 10:07:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -180.480 uVs 10:07:11 Integrated Voltage Measurement... 10:07:21 Voltage Offset Correction: v_off_ini = -208.913 uV, v_off_fin = -199.185 uV 10:07:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 172.170 uVs 10:07:21 Integrated Voltage Measurement... 10:07:30 Voltage Offset Correction: v_off_ini = -191.676 uV, v_off_fin = -224.898 uV 10:07:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.594 uVs 10:07:30 Integrated Voltage Measurement... 10:07:39 Voltage Offset Correction: v_off_ini = -217.373 uV, v_off_fin = -180.388 uV 10:07:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.004 uVs 10:07:39 Integrated Voltage Measurement... 10:07:48 Voltage Offset Correction: v_off_ini = -199.099 uV, v_off_fin = -218.546 uV 10:07:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -167.981 uVs 10:07:48 Integrated Voltage Measurement... 10:07:57 Voltage Offset Correction: v_off_ini = -200.528 uV, v_off_fin = -187.411 uV 10:07:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 186.663 uVs 10:08:01 I1Y Average and RMS of Measurements VT = -182.315 +- 7.777 uVs I1Y = -36.463 +- 1.555 uTm 10:08:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:08:09 Integrated Voltage Measurement... 10:08:19 Voltage Offset Correction: v_off_ini = -202.233 uV, v_off_fin = -196.305 uV 10:08:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 0.410 uVs 10:08:19 Integrated Voltage Measurement... 10:08:28 Voltage Offset Correction: v_off_ini = -208.635 uV, v_off_fin = -193.618 uV 10:08:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.221 uVs 10:08:28 Integrated Voltage Measurement... 10:08:38 Voltage Offset Correction: v_off_ini = -201.216 uV, v_off_fin = -208.245 uV 10:08:38 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -2.221 uVs 10:08:38 Integrated Voltage Measurement... 10:08:47 Voltage Offset Correction: v_off_ini = -203.126 uV, v_off_fin = -182.341 uV 10:08:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.724 uVs 10:08:48 Integrated Voltage Measurement... 10:08:57 Voltage Offset Correction: v_off_ini = -209.021 uV, v_off_fin = -208.139 uV 10:08:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.592 uVs 10:08:57 Integrated Voltage Measurement... 10:09:07 Voltage Offset Correction: v_off_ini = -212.187 uV, v_off_fin = -193.351 uV 10:09:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.279 uVs 10:09:09 I2X Average and RMS of Measurements VT = -8.771 +- 3.707 uVs I2X = 0.680 +- 0.287 uTm^2 10:09:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:09:17 Integrated Voltage Measurement... 10:09:27 Voltage Offset Correction: v_off_ini = -205.176 uV, v_off_fin = -197.361 uV 10:09:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.245 uVs 10:09:27 Integrated Voltage Measurement... 10:09:36 Voltage Offset Correction: v_off_ini = -205.378 uV, v_off_fin = -196.148 uV 10:09:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.842 uVs 10:09:36 Integrated Voltage Measurement... 10:09:46 Voltage Offset Correction: v_off_ini = -188.592 uV, v_off_fin = -192.446 uV 10:09:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -222.379 uVs 10:09:46 Integrated Voltage Measurement... 10:09:55 Voltage Offset Correction: v_off_ini = -191.781 uV, v_off_fin = -190.426 uV 10:09:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0001 mm dXY = -1.0000 mm VT = 192.212 uVs 10:09:55 Integrated Voltage Measurement... 10:10:05 Voltage Offset Correction: v_off_ini = -204.806 uV, v_off_fin = -188.222 uV 10:10:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.320 uVs 10:10:05 Integrated Voltage Measurement... 10:10:14 Voltage Offset Correction: v_off_ini = -188.712 uV, v_off_fin = -198.925 uV 10:10:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 207.403 uVs 10:10:17 I2Y Average and RMS of Measurements VT = -199.400 +- 7.477 uVs I2Y = -15.453 +- 0.579 uTm^2 10:10:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm