SLAC Magnetic Measurements Date: 01-06-2022 Time: 10:15:13 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: SXHEPS-000 Dataset Number: 1 Run Purpose: Tuning Run Type: Stretched wire Run Number: 1 Measurement Device: Stretched Wire Operator: YL Comment: Parameters: Measurement Type = I12XY VS X VS GAP I1X dy = 0.5000 mm I1Y dx = 0.5000 mm I2X dy = 1.0000 mm I2Y dx = 1.0000 mm Wire # Turns = 1 Preamplifier Gain = 10000.00 Field Integrals: Gap (mm) X0 (mm) Y0 (mm) I1x (uTm) I1y (uTm) I2x (uTm^2) I2y (uTm^2) ---------- ---------- ---------- ---------------------- ---------------------- ---------------------- ---------------------- 15.000 0.000 0.000 14.199+- 0.579 -32.808+- 1.924 3.720+- 0.230 -15.281+- 1.468