SLAC Magnetic Measurements Date: 01-14-2022 Time: 12:02:23 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: SXU_1M_PROTOTYPE DATASET Number: 1 Tuning Stage: Tuning Run Number: 87 Measurement Type: Long Coil Scans Operator: YL Comment: Cross-talk test; 7.2mm/35mm gaps, 10.0 cm distance Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 -7.568E-06 -100.891E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1Y_VS_X 0.000E-03 -7.602E-06 -101.343E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1Y_VS_X 0.000E-03 -7.781E-06 -103.732E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_X 0.000E-03 4.695E-06 62.586E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1X_VS_X 0.000E-03 4.595E-06 61.254E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1X_VS_X 0.000E-03 4.763E-06 63.498E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0