SLAC Magnetic Measurements Date: 01-14-2022 Time: 10:22:00 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: SXU_1M_PROTOTYPE DATASET Number: 1 Tuning Stage: Tuning Run Number: 59 Measurement Type: Long Coil Scans Operator: YL Comment: Cross-talk test; 7.2mm/35mm gaps, 15 cm distance Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1Y_VS_X 0.000E-03 -8.052E-06 -107.342E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1Y_VS_X 0.000E-03 -8.243E-06 -109.884E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1Y_VS_X 0.000E-03 -8.332E-06 -111.078E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I1X_VS_X 0.000E-03 4.961E-06 66.127E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1X_VS_X 0.000E-03 4.572E-06 60.946E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0 I1X_VS_X 0.000E-03 4.826E-06 64.336E-06 7.20000 0.00360 0 0.00360 0 0.00360 0 0.00360 0