SLAC Magnetic Measurements Date: 12-02-2021 Time: 14:14:32 Project: DUMMY Magnet Type: Phase Shifter Magnet Name: SXHEPS-000 Dataset Number: 1 Run Purpose: Tuning Run Type: Background Run Number: 8 Measurement Device: Stretched Wire Operator: YL Comment: 14:14:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:41 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:14:43 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:14:44 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:14:46 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.000500 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 14:14:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:14:59 Integrated Voltage Measurement... 14:15:08 Voltage Offset Correction: v_off_ini = 24.579 uV, v_off_fin = 36.399 uV 14:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -22.972 uVs 14:15:08 Integrated Voltage Measurement... 14:15:17 Voltage Offset Correction: v_off_ini = 39.875 uV, v_off_fin = 51.915 uV 14:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.723 uVs 14:15:17 Integrated Voltage Measurement... 14:15:26 Voltage Offset Correction: v_off_ini = 26.812 uV, v_off_fin = 27.227 uV 14:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.626 uVs 14:15:26 Integrated Voltage Measurement... 14:15:35 Voltage Offset Correction: v_off_ini = 30.842 uV, v_off_fin = 45.568 uV 14:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.325 uVs 14:15:35 Integrated Voltage Measurement... 14:15:44 Voltage Offset Correction: v_off_ini = 39.022 uV, v_off_fin = 30.529 uV 14:15:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.159 uVs 14:15:44 Integrated Voltage Measurement... 14:15:53 Voltage Offset Correction: v_off_ini = 15.951 uV, v_off_fin = 40.510 uV 14:15:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 56.833 uVs 14:15:53 Integrated Voltage Measurement... 14:16:02 Voltage Offset Correction: v_off_ini = 40.625 uV, v_off_fin = 36.744 uV 14:16:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.552 uVs 14:16:02 Integrated Voltage Measurement... 14:16:12 Voltage Offset Correction: v_off_ini = 54.957 uV, v_off_fin = 53.804 uV 14:16:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.155 uVs 14:16:12 Integrated Voltage Measurement... 14:16:21 Voltage Offset Correction: v_off_ini = 46.319 uV, v_off_fin = 44.110 uV 14:16:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.051 uVs 14:16:21 Integrated Voltage Measurement... 14:16:30 Voltage Offset Correction: v_off_ini = 54.349 uV, v_off_fin = 53.012 uV 14:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.342 uVs 14:16:34 I1X Average and RMS of Measurements VT = -51.374 +- 5.094 uVs I1X = 10.275 +- 1.019 uTm 14:16:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:41 Integrated Voltage Measurement... 14:16:50 Voltage Offset Correction: v_off_ini = 57.997 uV, v_off_fin = 36.933 uV 14:16:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -151.377 uVs 14:16:50 Integrated Voltage Measurement... 14:16:59 Voltage Offset Correction: v_off_ini = 62.925 uV, v_off_fin = 79.057 uV 14:16:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 130.237 uVs 14:16:59 Integrated Voltage Measurement... 14:17:08 Voltage Offset Correction: v_off_ini = 73.682 uV, v_off_fin = 53.000 uV 14:17:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -156.348 uVs 14:17:08 Integrated Voltage Measurement... 14:17:18 Voltage Offset Correction: v_off_ini = 67.505 uV, v_off_fin = 77.188 uV 14:17:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 137.792 uVs 14:17:18 Integrated Voltage Measurement... 14:17:27 Voltage Offset Correction: v_off_ini = 61.884 uV, v_off_fin = 49.874 uV 14:17:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -147.829 uVs 14:17:27 Integrated Voltage Measurement... 14:17:36 Voltage Offset Correction: v_off_ini = 64.797 uV, v_off_fin = 74.353 uV 14:17:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 159.755 uVs 14:17:36 Integrated Voltage Measurement... 14:17:45 Voltage Offset Correction: v_off_ini = 63.281 uV, v_off_fin = 54.736 uV 14:17:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -150.887 uVs 14:17:45 Integrated Voltage Measurement... 14:17:54 Voltage Offset Correction: v_off_ini = 68.190 uV, v_off_fin = 71.798 uV 14:17:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 149.478 uVs 14:17:54 Integrated Voltage Measurement... 14:18:03 Voltage Offset Correction: v_off_ini = 64.858 uV, v_off_fin = 56.463 uV 14:18:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -135.791 uVs 14:18:03 Integrated Voltage Measurement... 14:18:12 Voltage Offset Correction: v_off_ini = 69.255 uV, v_off_fin = 90.130 uV 14:18:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 153.498 uVs 14:18:17 I1Y Average and RMS of Measurements VT = -147.299 +- 4.466 uVs I1Y = -29.460 +- 0.893 uTm 14:18:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:25 Integrated Voltage Measurement... 14:18:34 Voltage Offset Correction: v_off_ini = 89.033 uV, v_off_fin = 71.617 uV 14:18:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -74.532 uVs 14:18:34 Integrated Voltage Measurement... 14:18:43 Voltage Offset Correction: v_off_ini = 88.329 uV, v_off_fin = 82.689 uV 14:18:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.591 uVs 14:18:44 Integrated Voltage Measurement... 14:18:53 Voltage Offset Correction: v_off_ini = 85.651 uV, v_off_fin = 80.059 uV 14:18:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.798 uVs 14:18:53 Integrated Voltage Measurement... 14:19:02 Voltage Offset Correction: v_off_ini = 87.757 uV, v_off_fin = 83.700 uV 14:19:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 67.883 uVs 14:19:03 Integrated Voltage Measurement... 14:19:12 Voltage Offset Correction: v_off_ini = 85.983 uV, v_off_fin = 87.123 uV 14:19:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.439 uVs 14:19:12 Integrated Voltage Measurement... 14:19:22 Voltage Offset Correction: v_off_ini = 91.631 uV, v_off_fin = 86.356 uV 14:19:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.611 uVs 14:19:22 Integrated Voltage Measurement... 14:19:31 Voltage Offset Correction: v_off_ini = 79.008 uV, v_off_fin = 82.549 uV 14:19:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -77.202 uVs 14:19:31 Integrated Voltage Measurement... 14:19:41 Voltage Offset Correction: v_off_ini = 84.648 uV, v_off_fin = 80.937 uV 14:19:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.186 uVs 14:19:41 Integrated Voltage Measurement... 14:19:50 Voltage Offset Correction: v_off_ini = 88.289 uV, v_off_fin = 68.434 uV 14:19:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.917 uVs 14:19:50 Integrated Voltage Measurement... 14:20:00 Voltage Offset Correction: v_off_ini = 76.270 uV, v_off_fin = 77.798 uV 14:20:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.168 uVs 14:20:02 I2X Average and RMS of Measurements VT = -60.933 +- 11.601 uVs I2X = 4.722 +- 0.899 uTm^2 14:20:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:20:10 Integrated Voltage Measurement... 14:20:19 Voltage Offset Correction: v_off_ini = 65.410 uV, v_off_fin = 70.175 uV 14:20:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -144.804 uVs 14:20:19 Integrated Voltage Measurement... 14:20:29 Voltage Offset Correction: v_off_ini = 65.568 uV, v_off_fin = 62.152 uV 14:20:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.311 uVs 14:20:29 Integrated Voltage Measurement... 14:20:38 Voltage Offset Correction: v_off_ini = 67.596 uV, v_off_fin = 71.106 uV 14:20:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -159.672 uVs 14:20:38 Integrated Voltage Measurement... 14:20:48 Voltage Offset Correction: v_off_ini = 53.431 uV, v_off_fin = 62.305 uV 14:20:48 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 179.919 uVs 14:20:48 Integrated Voltage Measurement... 14:20:57 Voltage Offset Correction: v_off_ini = 78.436 uV, v_off_fin = 74.633 uV 14:20:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.718 uVs 14:20:57 Integrated Voltage Measurement... 14:21:07 Voltage Offset Correction: v_off_ini = 85.637 uV, v_off_fin = 67.867 uV 14:21:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 173.904 uVs 14:21:07 Integrated Voltage Measurement... 14:21:16 Voltage Offset Correction: v_off_ini = 64.828 uV, v_off_fin = 62.520 uV 14:21:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -151.083 uVs 14:21:16 Integrated Voltage Measurement... 14:21:26 Voltage Offset Correction: v_off_ini = 73.121 uV, v_off_fin = 72.919 uV 14:21:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 171.304 uVs 14:21:26 Integrated Voltage Measurement... 14:21:35 Voltage Offset Correction: v_off_ini = 60.684 uV, v_off_fin = 64.068 uV 14:21:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -148.098 uVs 14:21:35 Integrated Voltage Measurement... 14:21:45 Voltage Offset Correction: v_off_ini = 66.074 uV, v_off_fin = 59.557 uV 14:21:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.609 uVs 14:21:48 I2Y Average and RMS of Measurements VT = -170.742 +- 15.537 uVs I2Y = -13.233 +- 1.204 uTm^2 14:21:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:31:56 Wire Position: X0 = 40.0000 mm, Y0 = 0.0000 mm