SLAC Magnetic Measurements Date: 02-05-2025 Time: 09:31:43 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_10088 Dataset Number: 1 Run Purpose: Final Results Run Type: Stretched Wire Run Number: 6 Measurement Device: Operator: YL Comment: Background 09:31:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:31:53 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:31:55 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:31:56 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:31:58 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:34:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:34:28 Integrated Voltage Measurement... 09:34:37 Voltage Offset Correction: v_off_ini = 636.202 uV, v_off_fin = 632.189 uV 09:34:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.583 uVs 09:34:37 Integrated Voltage Measurement... 09:34:46 Voltage Offset Correction: v_off_ini = 640.773 uV, v_off_fin = 624.612 uV 09:34:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 113.319 uVs 09:34:46 Integrated Voltage Measurement... 09:34:55 Voltage Offset Correction: v_off_ini = 623.872 uV, v_off_fin = 605.738 uV 09:34:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -131.856 uVs 09:34:55 Integrated Voltage Measurement... 09:35:04 Voltage Offset Correction: v_off_ini = 603.423 uV, v_off_fin = 632.774 uV 09:35:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 101.342 uVs 09:35:04 Integrated Voltage Measurement... 09:35:13 Voltage Offset Correction: v_off_ini = 620.802 uV, v_off_fin = 622.615 uV 09:35:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -108.283 uVs 09:35:13 Integrated Voltage Measurement... 09:35:22 Voltage Offset Correction: v_off_ini = 615.976 uV, v_off_fin = 634.823 uV 09:35:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 126.207 uVs 09:35:26 I1X Average and RMS of Measurements VT = -115.432 +- 2.124 uVs I1X = 23.086 +- 0.425 uTm 09:35:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:35:33 Integrated Voltage Measurement... 09:35:42 Voltage Offset Correction: v_off_ini = 631.862 uV, v_off_fin = 652.060 uV 09:35:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -214.568 uVs 09:35:42 Integrated Voltage Measurement... 09:35:51 Voltage Offset Correction: v_off_ini = 645.198 uV, v_off_fin = 643.978 uV 09:35:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.845 uVs 09:35:51 Integrated Voltage Measurement... 09:36:00 Voltage Offset Correction: v_off_ini = 633.665 uV, v_off_fin = 628.417 uV 09:36:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -237.632 uVs 09:36:00 Integrated Voltage Measurement... 09:36:09 Voltage Offset Correction: v_off_ini = 653.210 uV, v_off_fin = 657.939 uV 09:36:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 208.893 uVs 09:36:09 Integrated Voltage Measurement... 09:36:18 Voltage Offset Correction: v_off_ini = 642.518 uV, v_off_fin = 631.393 uV 09:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -215.371 uVs 09:36:18 Integrated Voltage Measurement... 09:36:27 Voltage Offset Correction: v_off_ini = 615.481 uV, v_off_fin = 640.147 uV 09:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.712 uVs 09:36:31 I1Y Average and RMS of Measurements VT = -224.003 +- 2.771 uVs I1Y = -44.801 +- 0.554 uTm 09:36:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:36:39 Integrated Voltage Measurement... 09:36:48 Voltage Offset Correction: v_off_ini = 630.384 uV, v_off_fin = 627.414 uV 09:36:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -126.673 uVs 09:36:48 Integrated Voltage Measurement... 09:36:57 Voltage Offset Correction: v_off_ini = 636.080 uV, v_off_fin = 642.319 uV 09:36:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 138.273 uVs 09:36:57 Integrated Voltage Measurement... 09:37:06 Voltage Offset Correction: v_off_ini = 648.321 uV, v_off_fin = 641.360 uV 09:37:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -150.607 uVs 09:37:06 Integrated Voltage Measurement... 09:37:15 Voltage Offset Correction: v_off_ini = 652.402 uV, v_off_fin = 667.680 uV 09:37:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 101.734 uVs 09:37:15 Integrated Voltage Measurement... 09:37:24 Voltage Offset Correction: v_off_ini = 646.832 uV, v_off_fin = 623.744 uV 09:37:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -119.175 uVs 09:37:24 Integrated Voltage Measurement... 09:37:33 Voltage Offset Correction: v_off_ini = 649.962 uV, v_off_fin = 651.454 uV 09:37:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 117.526 uVs 09:37:36 I2X Average and RMS of Measurements VT = -125.665 +- 5.777 uVs I2X = 11.561 +- 0.531 uTm^2 09:37:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:37:43 Integrated Voltage Measurement... 09:37:52 Voltage Offset Correction: v_off_ini = 638.226 uV, v_off_fin = 627.710 uV 09:37:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -210.163 uVs 09:37:53 Integrated Voltage Measurement... 09:38:02 Voltage Offset Correction: v_off_ini = 645.595 uV, v_off_fin = 642.011 uV 09:38:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 247.753 uVs 09:38:02 Integrated Voltage Measurement... 09:38:11 Voltage Offset Correction: v_off_ini = 636.620 uV, v_off_fin = 626.882 uV 09:38:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.196 uVs 09:38:11 Integrated Voltage Measurement... 09:38:20 Voltage Offset Correction: v_off_ini = 626.916 uV, v_off_fin = 650.698 uV 09:38:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.553 uVs 09:38:20 Integrated Voltage Measurement... 09:38:29 Voltage Offset Correction: v_off_ini = 602.683 uV, v_off_fin = 624.198 uV 09:38:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -208.006 uVs 09:38:29 Integrated Voltage Measurement... 09:38:38 Voltage Offset Correction: v_off_ini = 633.803 uV, v_off_fin = 642.405 uV 09:38:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 269.371 uVs 09:38:40 I2Y Average and RMS of Measurements VT = -232.507 +- 4.387 uVs I2Y = -21.391 +- 0.404 uTm^2 09:38:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:41:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:41:54 Integrated Voltage Measurement... 09:42:03 Voltage Offset Correction: v_off_ini = 634.587 uV, v_off_fin = 631.593 uV 09:42:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -100.840 uVs 09:42:03 Integrated Voltage Measurement... 09:42:12 Voltage Offset Correction: v_off_ini = 620.577 uV, v_off_fin = 636.114 uV 09:42:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 127.374 uVs 09:42:12 Integrated Voltage Measurement... 09:42:21 Voltage Offset Correction: v_off_ini = 649.848 uV, v_off_fin = 642.762 uV 09:42:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -128.194 uVs 09:42:21 Integrated Voltage Measurement... 09:42:30 Voltage Offset Correction: v_off_ini = 655.363 uV, v_off_fin = 662.885 uV 09:42:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 128.278 uVs 09:42:30 Integrated Voltage Measurement... 09:42:39 Voltage Offset Correction: v_off_ini = 663.412 uV, v_off_fin = 631.791 uV 09:42:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -94.684 uVs 09:42:39 Integrated Voltage Measurement... 09:42:48 Voltage Offset Correction: v_off_ini = 655.137 uV, v_off_fin = 656.154 uV 09:42:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 102.604 uVs 09:42:52 I1X Average and RMS of Measurements VT = -113.662 +- 12.085 uVs I1X = 22.732 +- 2.417 uTm 09:42:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:42:59 Integrated Voltage Measurement... 09:43:08 Voltage Offset Correction: v_off_ini = 658.444 uV, v_off_fin = 655.649 uV 09:43:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -212.461 uVs 09:43:08 Integrated Voltage Measurement... 09:43:17 Voltage Offset Correction: v_off_ini = 646.879 uV, v_off_fin = 657.603 uV 09:43:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.791 uVs 09:43:17 Integrated Voltage Measurement... 09:43:26 Voltage Offset Correction: v_off_ini = 647.988 uV, v_off_fin = 659.855 uV 09:43:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.893 uVs 09:43:26 Integrated Voltage Measurement... 09:43:35 Voltage Offset Correction: v_off_ini = 668.332 uV, v_off_fin = 669.948 uV 09:43:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.720 uVs 09:43:35 Integrated Voltage Measurement... 09:43:44 Voltage Offset Correction: v_off_ini = 671.624 uV, v_off_fin = 648.774 uV 09:43:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -213.240 uVs 09:43:44 Integrated Voltage Measurement... 09:43:53 Voltage Offset Correction: v_off_ini = 660.482 uV, v_off_fin = 659.500 uV 09:43:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 240.443 uVs 09:43:57 I1Y Average and RMS of Measurements VT = -221.258 +- 4.951 uVs I1Y = -44.252 +- 0.989 uTm 09:44:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:44:05 Integrated Voltage Measurement... 09:44:14 Voltage Offset Correction: v_off_ini = 645.986 uV, v_off_fin = 679.303 uV 09:44:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -102.705 uVs 09:44:14 Integrated Voltage Measurement... 09:44:23 Voltage Offset Correction: v_off_ini = 667.124 uV, v_off_fin = 677.559 uV 09:44:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 151.157 uVs 09:44:23 Integrated Voltage Measurement... 09:44:32 Voltage Offset Correction: v_off_ini = 680.636 uV, v_off_fin = 645.099 uV 09:44:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -96.647 uVs 09:44:32 Integrated Voltage Measurement... 09:44:41 Voltage Offset Correction: v_off_ini = 659.249 uV, v_off_fin = 682.360 uV 09:44:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 143.561 uVs 09:44:41 Integrated Voltage Measurement... 09:44:50 Voltage Offset Correction: v_off_ini = 669.340 uV, v_off_fin = 654.531 uV 09:44:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -116.917 uVs 09:44:50 Integrated Voltage Measurement... 09:44:59 Voltage Offset Correction: v_off_ini = 667.390 uV, v_off_fin = 677.249 uV 09:44:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 155.000 uVs 09:45:01 I2X Average and RMS of Measurements VT = -127.665 +- 6.493 uVs I2X = 11.745 +- 0.597 uTm^2 09:45:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:45:09 Integrated Voltage Measurement... 09:45:18 Voltage Offset Correction: v_off_ini = 652.212 uV, v_off_fin = 661.161 uV 09:45:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -230.174 uVs 09:45:18 Integrated Voltage Measurement... 09:45:27 Voltage Offset Correction: v_off_ini = 639.798 uV, v_off_fin = 631.020 uV 09:45:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.471 uVs 09:45:27 Integrated Voltage Measurement... 09:45:36 Voltage Offset Correction: v_off_ini = 642.244 uV, v_off_fin = 629.589 uV 09:45:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.544 uVs 09:45:36 Integrated Voltage Measurement... 09:45:45 Voltage Offset Correction: v_off_ini = 646.219 uV, v_off_fin = 659.451 uV 09:45:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.407 uVs 09:45:45 Integrated Voltage Measurement... 09:45:54 Voltage Offset Correction: v_off_ini = 652.175 uV, v_off_fin = 640.058 uV 09:45:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -226.937 uVs 09:45:54 Integrated Voltage Measurement... 09:46:03 Voltage Offset Correction: v_off_ini = 626.144 uV, v_off_fin = 667.269 uV 09:46:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.629 uVs 09:46:06 I2Y Average and RMS of Measurements VT = -225.860 +- 8.895 uVs I2Y = -20.780 +- 0.818 uTm^2 09:46:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm