Coil Constant for 1DQB Coil 2 Main Centered using magnet CAL Magnet Sext TB05SX1 New Calibrated Coil Constant = 317364.86567, File coilpar.ru (Old) Coil Constant = 316623.70720 New Constant/Old Constant = 1.0023, Old Coil Radius = 0.0124310, New Radius = 0.0025104, Number of coils = 1 (Only change radius if Number of coils = 1!) Wire Strength = 10.278539 T/m/A, Coil Strength = 10.254535 T/m/A, Magnet Type is Quadrupole at Imag = 7.000 for coil. Number of Coil Turns = 1 Coil Constant Calculated from radius, turns and magnet order = 12942.4907 (Should be within 5% of Calibrated Coil Constant)