SLAC Magnetic Measurements Date: 05-21-2025 Time: 10:32:23 Project: A-line Magnet Type: Quad Magnet Name: Q38 Serial Number: 10 Run Number: 2 Measurement Device: 10wire Operator: sda Comment: Integrated gradient vs current from 0-300-0 in 20 A steps Standardization for MAIN: 3 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for MAIN (A): 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00 200.00 220.00 240.00 260.00 280.00 300.00 280.00 260.00 240.00 220.00 200.00 180.00 160.00 140.00 120.00 100.00 80.00 60.00 40.00 20.00 0.00 10:32:48 Position moved: 0.000000 m 10:32:52 Magnet Current for MAIN, Imag = -0.0065 A Vtrans = -0.000065 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:53 Magnet Current for MAIN, Imag = -0.0061 A Vtrans = -0.000061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:54 Magnet Current for MAIN, Imag = -0.0061 A Vtrans = -0.000061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:55 Magnet Current for MAIN, Imag = -0.0057 A Vtrans = -0.000057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:55 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0061 +- 0.0003 A 10:33:01 Initial Zero Current Measurement for MAIN, Imag_zero = -0.0061 A 10:33:01 Ambient Measurement Device(s) Being Used, type = None 10:33:02 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 10:33:02 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 10:33:03 Ambient Measurement Device(s) Being Used, type = HP34970 10:33:03 Magnet system MAIN current ramping to 300.0000 A... 10:33:32 Magnet Current for MAIN, Imag = 300.0012 A Vtrans = 2.999951 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:33:33 Main (V) Voltage Measurement, V = 10.309672 V 10:33:34 Temperature Measurement, Probe Number = 0, T = 28.156000 C 10:33:41 Temperature Measurement, Probe Number = 1, T = 28.785000 C 10:33:42 Temperature Measurement, Probe Number = 2, T = 28.563000 C 10:33:43 Temperature Measurement, Probe Number = 3, T = 28.688000 C 10:33:44 Temperature Measurement, Probe Number = 4, T = 21.243000 C 10:33:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.351506 V 10:33:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.351506 (V, A, ohm, ...), Measured Value = 28.770918 (C, atm, Hz, ...) 10:33:45 Sensor Voltage Measurement, Sensor Number = 1, V = 2.266905 V 10:33:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.266905 (V, A, ohm, ...), Measured Value = 27.595897 (C, atm, Hz, ...) 10:33:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656217 V 10:33:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656217 (V, A, ohm, ...), Measured Value = 124.216305 (C, atm, Hz, ...) 10:33:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095470 V 10:33:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095470 (V, A, ohm, ...), Measured Value = 7.160220 (C, atm, Hz, ...) 10:33:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003241 V 10:33:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003241 (V, A, ohm, ...), Measured Value = 3.240579 (C, atm, Hz, ...) 10:33:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.31 P2 = Top Right Coil, Value = 28.16 P3 = Bottom Right Coil, Value = 28.79 P4 = Top Left Coil, Value = 28.56 P5 = Bottom Left Coil, Value = 28.69 P6 = Ambient, Value = 21.24 P7 = Supply Temp(C), Value = 28.77 P8 = Return Temp(C), Value = 27.60 P9 = Supply Pres(psi), Value = 124.22 P10 = Return Pres(psi), Value = 7.16 P11 = Flow Rate(gpm), Value = 3.24 10:34:51 Magnet Current for MAIN, Imag = 300.0023 A Vtrans = 2.999962 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:34:52 Main (V) Voltage Measurement, V = 10.326955 V 10:34:53 Temperature Measurement, Probe Number = 0, T = 29.490000 C 10:34:57 Temperature Measurement, Probe Number = 1, T = 30.023000 C 10:34:58 Temperature Measurement, Probe Number = 2, T = 29.284000 C 10:34:59 Temperature Measurement, Probe Number = 3, T = 30.210000 C 10:35:00 Temperature Measurement, Probe Number = 4, T = 21.278000 C 10:35:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.351875 V 10:35:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.351875 (V, A, ohm, ...), Measured Value = 28.776038 (C, atm, Hz, ...) 10:35:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.274063 V 10:35:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.274063 (V, A, ohm, ...), Measured Value = 27.695324 (C, atm, Hz, ...) 10:35:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.647678 V 10:35:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.647678 (V, A, ohm, ...), Measured Value = 123.575872 (C, atm, Hz, ...) 10:35:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095364 V 10:35:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095364 (V, A, ohm, ...), Measured Value = 7.152315 (C, atm, Hz, ...) 10:35:06 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003244 V 10:35:06 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003244 (V, A, ohm, ...), Measured Value = 3.243520 (C, atm, Hz, ...) 10:35:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 29.49 P3 = Bottom Right Coil, Value = 30.02 P4 = Top Left Coil, Value = 29.28 P5 = Bottom Left Coil, Value = 30.21 P6 = Ambient, Value = 21.28 P7 = Supply Temp(C), Value = 28.78 P8 = Return Temp(C), Value = 27.70 P9 = Supply Pres(psi), Value = 123.58 P10 = Return Pres(psi), Value = 7.15 P11 = Flow Rate(gpm), Value = 3.24 10:36:07 Magnet Current for MAIN, Imag = 300.0038 A Vtrans = 2.999977 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:36:08 Main (V) Voltage Measurement, V = 10.327304 V 10:36:09 Temperature Measurement, Probe Number = 0, T = 29.957000 C 10:36:13 Temperature Measurement, Probe Number = 1, T = 30.335000 C 10:36:14 Temperature Measurement, Probe Number = 2, T = 29.555000 C 10:36:15 Temperature Measurement, Probe Number = 3, T = 30.547000 C 10:36:15 Temperature Measurement, Probe Number = 4, T = 21.277000 C 10:36:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.352290 V 10:36:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352290 (V, A, ohm, ...), Measured Value = 28.781811 (C, atm, Hz, ...) 10:36:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.291754 V 10:36:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.291754 (V, A, ohm, ...), Measured Value = 27.941029 (C, atm, Hz, ...) 10:36:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670047 V 10:36:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670047 (V, A, ohm, ...), Measured Value = 125.253495 (C, atm, Hz, ...) 10:36:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097971 V 10:36:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097971 (V, A, ohm, ...), Measured Value = 7.347833 (C, atm, Hz, ...) 10:36:22 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003239 V 10:36:22 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003239 (V, A, ohm, ...), Measured Value = 3.239407 (C, atm, Hz, ...) 10:36:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 29.96 P3 = Bottom Right Coil, Value = 30.34 P4 = Top Left Coil, Value = 29.55 P5 = Bottom Left Coil, Value = 30.55 P6 = Ambient, Value = 21.28 P7 = Supply Temp(C), Value = 28.78 P8 = Return Temp(C), Value = 27.94 P9 = Supply Pres(psi), Value = 125.25 P10 = Return Pres(psi), Value = 7.35 P11 = Flow Rate(gpm), Value = 3.24 10:37:23 Magnet Current for MAIN, Imag = 300.0026 A Vtrans = 2.999965 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:37:24 Main (V) Voltage Measurement, V = 10.327524 V 10:37:25 Temperature Measurement, Probe Number = 0, T = 30.068000 C 10:37:29 Temperature Measurement, Probe Number = 1, T = 30.384000 C 10:37:29 Temperature Measurement, Probe Number = 2, T = 29.600000 C 10:37:30 Temperature Measurement, Probe Number = 3, T = 30.618000 C 10:37:31 Temperature Measurement, Probe Number = 4, T = 21.372000 C 10:37:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.352616 V 10:37:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352616 (V, A, ohm, ...), Measured Value = 28.786331 (C, atm, Hz, ...) 10:37:33 Sensor Voltage Measurement, Sensor Number = 1, V = 2.313104 V 10:37:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313104 (V, A, ohm, ...), Measured Value = 28.237561 (C, atm, Hz, ...) 10:37:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660069 V 10:37:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660069 (V, A, ohm, ...), Measured Value = 124.505153 (C, atm, Hz, ...) 10:37:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096148 V 10:37:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096148 (V, A, ohm, ...), Measured Value = 7.211130 (C, atm, Hz, ...) 10:37:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003235 V 10:37:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003235 (V, A, ohm, ...), Measured Value = 3.234838 (C, atm, Hz, ...) 10:37:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 30.07 P3 = Bottom Right Coil, Value = 30.38 P4 = Top Left Coil, Value = 29.60 P5 = Bottom Left Coil, Value = 30.62 P6 = Ambient, Value = 21.37 P7 = Supply Temp(C), Value = 28.79 P8 = Return Temp(C), Value = 28.24 P9 = Supply Pres(psi), Value = 124.51 P10 = Return Pres(psi), Value = 7.21 P11 = Flow Rate(gpm), Value = 3.23 10:38:39 Magnet Current for MAIN, Imag = 300.0030 A Vtrans = 2.999969 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:38:40 Main (V) Voltage Measurement, V = 10.327626 V 10:38:41 Temperature Measurement, Probe Number = 0, T = 30.094000 C 10:38:44 Temperature Measurement, Probe Number = 1, T = 30.399000 C 10:38:45 Temperature Measurement, Probe Number = 2, T = 29.632000 C 10:38:46 Temperature Measurement, Probe Number = 3, T = 30.651000 C 10:38:47 Temperature Measurement, Probe Number = 4, T = 21.405000 C 10:38:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.352606 V 10:38:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352606 (V, A, ohm, ...), Measured Value = 28.786189 (C, atm, Hz, ...) 10:38:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.335189 V 10:38:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335189 (V, A, ohm, ...), Measured Value = 28.544296 (C, atm, Hz, ...) 10:38:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.644122 V 10:38:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.644122 (V, A, ohm, ...), Measured Value = 123.309135 (C, atm, Hz, ...) 10:38:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096541 V 10:38:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096541 (V, A, ohm, ...), Measured Value = 7.240590 (C, atm, Hz, ...) 10:38:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003238 V 10:38:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003238 (V, A, ohm, ...), Measured Value = 3.237638 (C, atm, Hz, ...) 10:38:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 30.09 P3 = Bottom Right Coil, Value = 30.40 P4 = Top Left Coil, Value = 29.63 P5 = Bottom Left Coil, Value = 30.65 P6 = Ambient, Value = 21.41 P7 = Supply Temp(C), Value = 28.79 P8 = Return Temp(C), Value = 28.54 P9 = Supply Pres(psi), Value = 123.31 P10 = Return Pres(psi), Value = 7.24 P11 = Flow Rate(gpm), Value = 3.24 10:39:55 Magnet Current for MAIN, Imag = 300.0031 A Vtrans = 2.999970 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:39:55 Main (V) Voltage Measurement, V = 10.328094 V 10:39:56 Temperature Measurement, Probe Number = 0, T = 30.132000 C 10:40:00 Temperature Measurement, Probe Number = 1, T = 30.390000 C 10:40:01 Temperature Measurement, Probe Number = 2, T = 29.656000 C 10:40:02 Temperature Measurement, Probe Number = 3, T = 30.598000 C 10:40:03 Temperature Measurement, Probe Number = 4, T = 21.473000 C 10:40:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.352869 V 10:40:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352869 (V, A, ohm, ...), Measured Value = 28.789843 (C, atm, Hz, ...) 10:40:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355274 V 10:40:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355274 (V, A, ohm, ...), Measured Value = 28.823244 (C, atm, Hz, ...) 10:40:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659062 V 10:40:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659062 (V, A, ohm, ...), Measured Value = 124.429650 (C, atm, Hz, ...) 10:40:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096550 V 10:40:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096550 (V, A, ohm, ...), Measured Value = 7.241257 (C, atm, Hz, ...) 10:40:09 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003245 V 10:40:09 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003245 (V, A, ohm, ...), Measured Value = 3.244752 (C, atm, Hz, ...) 10:40:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 30.13 P3 = Bottom Right Coil, Value = 30.39 P4 = Top Left Coil, Value = 29.66 P5 = Bottom Left Coil, Value = 30.60 P6 = Ambient, Value = 21.47 P7 = Supply Temp(C), Value = 28.79 P8 = Return Temp(C), Value = 28.82 P9 = Supply Pres(psi), Value = 124.43 P10 = Return Pres(psi), Value = 7.24 P11 = Flow Rate(gpm), Value = 3.24 10:41:10 Magnet Current for MAIN, Imag = 300.0045 A Vtrans = 2.999984 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:41:11 Main (V) Voltage Measurement, V = 10.328513 V 10:41:12 Temperature Measurement, Probe Number = 0, T = 30.152000 C 10:41:16 Temperature Measurement, Probe Number = 1, T = 30.391000 C 10:41:17 Temperature Measurement, Probe Number = 2, T = 29.613000 C 10:41:18 Temperature Measurement, Probe Number = 3, T = 30.667000 C 10:41:18 Temperature Measurement, Probe Number = 4, T = 21.459000 C 10:41:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.353006 V 10:41:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353006 (V, A, ohm, ...), Measured Value = 28.791750 (C, atm, Hz, ...) 10:41:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.373042 V 10:41:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.373042 (V, A, ohm, ...), Measured Value = 29.070026 (C, atm, Hz, ...) 10:41:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655124 V 10:41:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655124 (V, A, ohm, ...), Measured Value = 124.134315 (C, atm, Hz, ...) 10:41:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096181 V 10:41:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096181 (V, A, ohm, ...), Measured Value = 7.213612 (C, atm, Hz, ...) 10:41:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003233 V 10:41:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003233 (V, A, ohm, ...), Measured Value = 3.232968 (C, atm, Hz, ...) 10:41:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 30.15 P3 = Bottom Right Coil, Value = 30.39 P4 = Top Left Coil, Value = 29.61 P5 = Bottom Left Coil, Value = 30.67 P6 = Ambient, Value = 21.46 P7 = Supply Temp(C), Value = 28.79 P8 = Return Temp(C), Value = 29.07 P9 = Supply Pres(psi), Value = 124.13 P10 = Return Pres(psi), Value = 7.21 P11 = Flow Rate(gpm), Value = 3.23 10:42:26 Magnet Current for MAIN, Imag = 300.0040 A Vtrans = 2.999979 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:42:27 Main (V) Voltage Measurement, V = 10.328480 V 10:42:28 Temperature Measurement, Probe Number = 0, T = 30.186000 C 10:42:32 Temperature Measurement, Probe Number = 1, T = 30.433000 C 10:42:33 Temperature Measurement, Probe Number = 2, T = 29.677000 C 10:42:33 Temperature Measurement, Probe Number = 3, T = 30.646000 C 10:42:34 Temperature Measurement, Probe Number = 4, T = 21.423000 C 10:42:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.353155 V 10:42:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353155 (V, A, ohm, ...), Measured Value = 28.793815 (C, atm, Hz, ...) 10:42:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.388370 V 10:42:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.388370 (V, A, ohm, ...), Measured Value = 29.282914 (C, atm, Hz, ...) 10:42:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.644668 V 10:42:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.644668 (V, A, ohm, ...), Measured Value = 123.350130 (C, atm, Hz, ...) 10:42:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096070 V 10:42:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096070 (V, A, ohm, ...), Measured Value = 7.205220 (C, atm, Hz, ...) 10:42:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003243 V 10:42:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003243 (V, A, ohm, ...), Measured Value = 3.243002 (C, atm, Hz, ...) 10:42:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.00 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 30.19 P3 = Bottom Right Coil, Value = 30.43 P4 = Top Left Coil, Value = 29.68 P5 = Bottom Left Coil, Value = 30.65 P6 = Ambient, Value = 21.42 P7 = Supply Temp(C), Value = 28.79 P8 = Return Temp(C), Value = 29.28 P9 = Supply Pres(psi), Value = 123.35 P10 = Return Pres(psi), Value = 7.21 P11 = Flow Rate(gpm), Value = 3.24 10:43:42 Magnet Current for MAIN, Imag = 300.0059 A Vtrans = 2.999998 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:43:43 Main (V) Voltage Measurement, V = 10.328755 V 10:43:44 Temperature Measurement, Probe Number = 0, T = 30.184000 C 10:43:47 Temperature Measurement, Probe Number = 1, T = 30.449000 C 10:43:48 Temperature Measurement, Probe Number = 2, T = 29.693000 C 10:43:49 Temperature Measurement, Probe Number = 3, T = 30.671000 C 10:43:50 Temperature Measurement, Probe Number = 4, T = 21.403000 C 10:43:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.353386 V 10:43:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353386 (V, A, ohm, ...), Measured Value = 28.797028 (C, atm, Hz, ...) 10:43:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.401818 V 10:43:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.401818 (V, A, ohm, ...), Measured Value = 29.469692 (C, atm, Hz, ...) 10:43:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651128 V 10:43:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651128 (V, A, ohm, ...), Measured Value = 123.834600 (C, atm, Hz, ...) 10:43:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096309 V 10:43:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096309 (V, A, ohm, ...), Measured Value = 7.223145 (C, atm, Hz, ...) 10:43:57 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003229 V 10:43:57 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003229 (V, A, ohm, ...), Measured Value = 3.228607 (C, atm, Hz, ...) 10:43:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.01 P1 = Main (V), Value = 10.33 P2 = Top Right Coil, Value = 30.18 P3 = Bottom Right Coil, Value = 30.45 P4 = Top Left Coil, Value = 29.69 P5 = Bottom Left Coil, Value = 30.67 P6 = Ambient, Value = 21.40 P7 = Supply Temp(C), Value = 28.80 P8 = Return Temp(C), Value = 29.47 P9 = Supply Pres(psi), Value = 123.83 P10 = Return Pres(psi), Value = 7.22 P11 = Flow Rate(gpm), Value = 3.23 10:43:57 Magnet system MAIN current ramping to 0.0000 A... 10:44:46 Magnet system MAIN current ramping to 300.0000 A... 10:45:34 Magnet system MAIN current ramping to 0.0000 A... 10:46:23 Magnet system MAIN current ramping to 300.0000 A... 10:47:11 Magnet system MAIN current ramping to 0.0000 A... 10:48:00 Magnet system MAIN current ramping to 300.0000 A... 10:48:48 Magnet system MAIN current ramping to 0.0000 A... 10:49:40 Position moved: 0.000000 m 10:49:42 Magnet system MAIN current ramping to 0.0000 A... 10:50:04 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:50:05 Main (V) Voltage Measurement, V = 0.000281 V 10:50:06 Temperature Measurement, Probe Number = 0, T = 28.661000 C 10:50:10 Temperature Measurement, Probe Number = 1, T = 28.794000 C 10:50:10 Temperature Measurement, Probe Number = 2, T = 28.645000 C 10:50:11 Temperature Measurement, Probe Number = 3, T = 28.795000 C 10:50:12 Temperature Measurement, Probe Number = 4, T = 21.495000 C 10:50:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.353593 V 10:50:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353593 (V, A, ohm, ...), Measured Value = 28.799906 (C, atm, Hz, ...) 10:50:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.402727 V 10:50:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.402727 (V, A, ohm, ...), Measured Value = 29.482314 (C, atm, Hz, ...) 10:50:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653500 V 10:50:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653500 (V, A, ohm, ...), Measured Value = 124.012485 (C, atm, Hz, ...) 10:50:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096945 V 10:50:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096945 (V, A, ohm, ...), Measured Value = 7.270905 (C, atm, Hz, ...) 10:50:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003206 V 10:50:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003206 (V, A, ohm, ...), Measured Value = 3.205534 (C, atm, Hz, ...) 10:50:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = Main (V), Value = 0.00 P2 = Top Right Coil, Value = 28.66 P3 = Bottom Right Coil, Value = 28.79 P4 = Top Left Coil, Value = 28.64 P5 = Bottom Left Coil, Value = 28.80 P6 = Ambient, Value = 21.50 P7 = Supply Temp(C), Value = 28.80 P8 = Return Temp(C), Value = 29.48 P9 = Supply Pres(psi), Value = 124.01 P10 = Return Pres(psi), Value = 7.27 P11 = Flow Rate(gpm), Value = 3.21 10:50:19 Magnetic Field Measurement Measuring the magnet strength... 10:50:19 Integrated Voltage Measurement... 10:50:20 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:50:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000037116 Vs 10:50:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000041587 Vs 10:50:40 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:50:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000036104 Vs 10:50:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000042008 Vs 10:50:59 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:51:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000035741 Vs 10:51:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000042007 Vs 10:51:19 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:51:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000035983 Vs 10:51:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000041247 Vs 10:51:37 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000038974 +- 0.000000268 Vs 10:51:37 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000038974 +- 0.000000268 Vs BL = 0.00038974 +- 0.00000268 Tm 10:51:37 Integrated Voltage Measurement... 10:51:38 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:51:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000022756 Vs 10:51:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000027142 Vs 10:51:58 Magnet Current for MAIN, Imag = 0.0094 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:52:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000022253 Vs 10:52:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000026969 Vs 10:52:18 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:52:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000023184 Vs 10:52:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000026519 Vs 10:52:37 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:52:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000023367 Vs 10:52:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000026726 Vs 10:52:55 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000024865 +- 0.000000162 Vs 10:52:55 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000024865 +- 0.000000162 Vs BL = 0.00024865 +- 0.00000162 Tm 10:52:55 Integrated Voltage Measurement... 10:52:56 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:53:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000009164 Vs 10:53:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000014079 Vs 10:53:16 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:53:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000009165 Vs 10:53:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000014520 Vs 10:53:36 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:53:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000008601 Vs 10:53:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000014861 Vs 10:53:55 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:54:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000008645 Vs 10:54:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000015017 Vs 10:54:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000011756 +- 0.000000089 Vs 10:54:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000011756 +- 0.000000089 Vs BL = 0.00011756 +- 0.00000089 Tm 10:54:13 Integrated Voltage Measurement... 10:54:14 Magnet Current for MAIN, Imag = 0.0085 A Vtrans = 0.000024 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:54:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000019238 Vs 10:54:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000012673 Vs 10:54:35 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:54:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000020089 Vs 10:54:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000012692 Vs 10:54:54 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:55:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000019138 Vs 10:55:12 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000013712 Vs 10:55:13 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:55:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000018791 Vs 10:55:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000012986 Vs 10:55:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000016165 +- 0.000000244 Vs 10:55:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000016165 +- 0.000000244 Vs BL = -0.00016165 +- 0.00000244 Tm 10:55:31 Integrated Voltage Measurement... 10:55:32 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:55:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000033108 Vs 10:55:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000027642 Vs 10:55:53 Magnet Current for MAIN, Imag = 0.0088 A Vtrans = 0.000027 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:56:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000032345 Vs 10:56:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000028520 Vs 10:56:12 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:56:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000032159 Vs 10:56:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000028474 Vs 10:56:31 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:56:40 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000031923 Vs 10:56:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000028310 Vs 10:56:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000030310 +- 0.000000119 Vs 10:56:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000030310 +- 0.000000119 Vs BL = -0.00030310 +- 0.00000119 Tm 10:56:49 Integrated Voltage Measurement... 10:56:50 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000028 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:57:00 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000044679 Vs 10:57:09 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000042102 Vs 10:57:11 Magnet Current for MAIN, Imag = 0.0088 A Vtrans = 0.000027 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:57:20 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000046055 Vs 10:57:29 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000041432 Vs 10:57:30 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:57:39 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000046035 Vs 10:57:48 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000041197 Vs 10:57:49 Magnet Current for MAIN, Imag = 0.0092 A Vtrans = 0.000030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:57:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000046737 Vs 10:58:07 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000040837 Vs 10:58:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000043634 +- 0.000000154 Vs 10:58:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000043634 +- 0.000000154 Vs BL = -0.00043634 +- 0.00000154 Tm 10:58:11 Position moved: 0.000000 m 10:58:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00002 0.00000 1 -0.01379 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.00039 0.00000 0.00039 0.00000 -0.0200000 0.00025 0.00000 0.00025 -0.00000 -0.0100000 0.00012 0.00000 0.00011 0.00000 0.0100000 -0.00016 0.00000 -0.00016 0.00000 0.0200000 -0.00030 0.00000 -0.00030 -0.00000 0.0300000 -0.00044 0.00000 -0.00044 0.00000 10:58:11 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.00039 0.00000 -0.0200 0.00025 0.00000 -0.0100 0.00012 0.00000 0.0100 -0.00016 0.00000 0.0200 -0.00030 0.00000 0.0300 -0.00044 0.00000 SL = -0.0137891 +- 0.0000373 Tm^2/m^n 10:58:11 Quadrupole Strength Calculation Check Slope = -0.013789 Tm/m, Inter = -0.000024 Tm, Sig_slope = 0.000057 Tm/m, Est_sig = 0.000003 Tm GL = -0.013789 +- 0.000057 T 10:58:11 Magnet Strength Measurement Harmonic Number = 2 SL = -0.0137891 +- 0.0000373 Tm^2/m^n 10:58:14 Position moved: 0.000000 m 10:58:14 Magnet system MAIN current ramping to 20.0000 A... 10:58:37 Magnet Current for MAIN, Imag = 19.9773 A Vtrans = 0.199712 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:58:38 Main (V) Voltage Measurement, V = 0.682708 V 10:58:39 Temperature Measurement, Probe Number = 0, T = 28.086000 C 10:58:43 Temperature Measurement, Probe Number = 1, T = 28.413000 C 10:58:44 Temperature Measurement, Probe Number = 2, T = 28.345000 C 10:58:44 Temperature Measurement, Probe Number = 3, T = 28.362000 C 10:58:45 Temperature Measurement, Probe Number = 4, T = 21.673000 C 10:58:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.354333 V 10:58:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354333 (V, A, ohm, ...), Measured Value = 28.810181 (C, atm, Hz, ...) 10:58:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.324022 V 10:58:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324022 (V, A, ohm, ...), Measured Value = 28.389190 (C, atm, Hz, ...) 10:58:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653604 V 10:58:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653604 (V, A, ohm, ...), Measured Value = 124.020300 (C, atm, Hz, ...) 10:58:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097352 V 10:58:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097352 (V, A, ohm, ...), Measured Value = 7.301407 (C, atm, Hz, ...) 10:58:52 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003202 V 10:58:52 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003202 (V, A, ohm, ...), Measured Value = 3.201940 (C, atm, Hz, ...) 10:58:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = Main (V), Value = 0.68 P2 = Top Right Coil, Value = 28.09 P3 = Bottom Right Coil, Value = 28.41 P4 = Top Left Coil, Value = 28.34 P5 = Bottom Left Coil, Value = 28.36 P6 = Ambient, Value = 21.67 P7 = Supply Temp(C), Value = 28.81 P8 = Return Temp(C), Value = 28.39 P9 = Supply Pres(psi), Value = 124.02 P10 = Return Pres(psi), Value = 7.30 P11 = Flow Rate(gpm), Value = 3.20 10:58:52 Magnetic Field Measurement Measuring the magnet strength... 10:58:52 Integrated Voltage Measurement... 10:58:53 Magnet Current for MAIN, Imag = 19.9771 A Vtrans = 0.199710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:59:03 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001143929 Vs 10:59:12 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001147173 Vs 10:59:13 Magnet Current for MAIN, Imag = 19.9771 A Vtrans = 0.199710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:59:22 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001143362 Vs 10:59:32 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001147495 Vs 10:59:33 Magnet Current for MAIN, Imag = 19.9775 A Vtrans = 0.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 10:59:42 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001143476 Vs 10:59:51 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001147813 Vs 10:59:52 Magnet Current for MAIN, Imag = 19.9767 A Vtrans = 0.199706 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:00:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001143188 Vs 11:00:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001147746 Vs 11:00:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001145523 +- 0.000000083 Vs 11:00:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001145523 +- 0.000000083 Vs BL = 0.01145523 +- 0.00000083 Tm 11:00:10 Integrated Voltage Measurement... 11:00:11 Magnet Current for MAIN, Imag = 19.9771 A Vtrans = 0.199710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:00:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000762643 Vs 11:00:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000766129 Vs 11:00:31 Magnet Current for MAIN, Imag = 19.9768 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:00:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000761941 Vs 11:00:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000765778 Vs 11:00:51 Magnet Current for MAIN, Imag = 19.9771 A Vtrans = 0.199710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:01:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000762092 Vs 11:01:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000765402 Vs 11:01:10 Magnet Current for MAIN, Imag = 19.9776 A Vtrans = 0.199715 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:01:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000762132 Vs 11:01:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000765453 Vs 11:01:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000763946 +- 0.000000257 Vs 11:01:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000763946 +- 0.000000257 Vs BL = 0.00763946 +- 0.00000257 Tm 11:01:28 Integrated Voltage Measurement... 11:01:29 Magnet Current for MAIN, Imag = 19.9772 A Vtrans = 0.199711 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:01:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000381949 Vs 11:01:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000385826 Vs 11:01:49 Magnet Current for MAIN, Imag = 19.9775 A Vtrans = 0.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:01:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000381357 Vs 11:02:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000385985 Vs 11:02:09 Magnet Current for MAIN, Imag = 19.9768 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:02:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000381413 Vs 11:02:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000385649 Vs 11:02:28 Magnet Current for MAIN, Imag = 19.9770 A Vtrans = 0.199709 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:02:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000380967 Vs 11:02:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000386238 Vs 11:02:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000383673 +- 0.000000133 Vs 11:02:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000383673 +- 0.000000133 Vs BL = 0.00383673 +- 0.00000133 Tm 11:02:46 Integrated Voltage Measurement... 11:02:47 Magnet Current for MAIN, Imag = 19.9770 A Vtrans = 0.199709 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:02:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000379653 Vs 11:03:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000374272 Vs 11:03:07 Magnet Current for MAIN, Imag = 19.9768 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:03:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000380225 Vs 11:03:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000374177 Vs 11:03:27 Magnet Current for MAIN, Imag = 19.9770 A Vtrans = 0.199709 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:03:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000380012 Vs 11:03:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000373664 Vs 11:03:46 Magnet Current for MAIN, Imag = 19.9768 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:03:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000380227 Vs 11:04:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000373812 Vs 11:04:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000377005 +- 0.000000131 Vs 11:04:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000377005 +- 0.000000131 Vs BL = -0.00377005 +- 0.00000131 Tm 11:04:04 Integrated Voltage Measurement... 11:04:05 Magnet Current for MAIN, Imag = 19.9768 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:04:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000760866 Vs 11:04:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000754496 Vs 11:04:25 Magnet Current for MAIN, Imag = 19.9770 A Vtrans = 0.199709 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:04:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000761688 Vs 11:04:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000754747 Vs 11:04:44 Magnet Current for MAIN, Imag = 19.9767 A Vtrans = 0.199706 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:04:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000761284 Vs 11:05:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000754677 Vs 11:05:04 Magnet Current for MAIN, Imag = 19.9767 A Vtrans = 0.199706 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:05:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000760706 Vs 11:05:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000754704 Vs 11:05:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000757896 +- 0.000000220 Vs 11:05:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000757896 +- 0.000000220 Vs BL = -0.00757896 +- 0.00000220 Tm 11:05:22 Integrated Voltage Measurement... 11:05:23 Magnet Current for MAIN, Imag = 19.9770 A Vtrans = 0.199709 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:05:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001140364 Vs 11:05:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001136290 Vs 11:05:43 Magnet Current for MAIN, Imag = 19.9768 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:05:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001140647 Vs 11:06:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001136129 Vs 11:06:02 Magnet Current for MAIN, Imag = 19.9771 A Vtrans = 0.199710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:06:11 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001141192 Vs 11:06:20 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001136062 Vs 11:06:21 Magnet Current for MAIN, Imag = 19.9770 A Vtrans = 0.199709 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:06:31 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001141053 Vs 11:06:40 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001135937 Vs 11:06:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001138459 +- 0.000000114 Vs 11:06:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001138459 +- 0.000000114 Vs BL = -0.01138459 +- 0.00000114 Tm 11:06:44 Position moved: 0.000000 m 11:06:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00003 0.00000 1 -0.38058 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.01146 0.00000 0.01145 0.00000 -0.0200000 0.00764 0.00000 0.00764 -0.00001 -0.0100000 0.00384 0.00000 0.00384 -0.00000 0.0100000 -0.00377 0.00000 -0.00377 0.00000 0.0200000 -0.00758 0.00000 -0.00758 -0.00000 0.0300000 -0.01138 0.00000 -0.01138 -0.00000 11:06:44 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.01146 0.00000 -0.0200 0.00764 0.00000 -0.0100 0.00384 0.00000 0.0100 -0.00377 0.00000 0.0200 -0.00758 0.00000 0.0300 -0.01138 0.00000 SL = -0.3805824 +- 0.0000293 Tm^2/m^n 11:06:44 Quadrupole Strength Calculation Check Slope = -0.380582 Tm/m, Inter = 0.000033 Tm, Sig_slope = 0.000074 Tm/m, Est_sig = 0.000004 Tm GL = -0.380582 +- 0.000074 T 11:06:44 Magnet Strength Measurement Harmonic Number = 2 SL = -0.3805824 +- 0.0000293 Tm^2/m^n 11:06:47 Position moved: 0.000000 m 11:06:47 Magnet system MAIN current ramping to 40.0000 A... 11:07:10 Magnet Current for MAIN, Imag = 39.9605 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:07:11 Main (V) Voltage Measurement, V = 1.365746 V 11:07:12 Temperature Measurement, Probe Number = 0, T = 28.126000 C 11:07:15 Temperature Measurement, Probe Number = 1, T = 28.456000 C 11:07:16 Temperature Measurement, Probe Number = 2, T = 28.416000 C 11:07:17 Temperature Measurement, Probe Number = 3, T = 28.387000 C 11:07:18 Temperature Measurement, Probe Number = 4, T = 21.813000 C 11:07:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355265 V 11:07:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355265 (V, A, ohm, ...), Measured Value = 28.823121 (C, atm, Hz, ...) 11:07:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.306576 V 11:07:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.306576 (V, A, ohm, ...), Measured Value = 28.146890 (C, atm, Hz, ...) 11:07:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657814 V 11:07:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657814 (V, A, ohm, ...), Measured Value = 124.336035 (C, atm, Hz, ...) 11:07:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095929 V 11:07:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095929 (V, A, ohm, ...), Measured Value = 7.194638 (C, atm, Hz, ...) 11:07:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003236 V 11:07:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003236 (V, A, ohm, ...), Measured Value = 3.236440 (C, atm, Hz, ...) 11:07:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = Main (V), Value = 1.37 P2 = Top Right Coil, Value = 28.13 P3 = Bottom Right Coil, Value = 28.46 P4 = Top Left Coil, Value = 28.42 P5 = Bottom Left Coil, Value = 28.39 P6 = Ambient, Value = 21.81 P7 = Supply Temp(C), Value = 28.82 P8 = Return Temp(C), Value = 28.15 P9 = Supply Pres(psi), Value = 124.34 P10 = Return Pres(psi), Value = 7.19 P11 = Flow Rate(gpm), Value = 3.24 11:07:25 Magnetic Field Measurement Measuring the magnet strength... 11:07:25 Integrated Voltage Measurement... 11:07:26 Magnet Current for MAIN, Imag = 39.9609 A Vtrans = 0.399548 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:07:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002253211 Vs 11:07:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002258639 Vs 11:07:46 Magnet Current for MAIN, Imag = 39.9605 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:07:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002253413 Vs 11:08:04 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002258061 Vs 11:08:05 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:08:14 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002253769 Vs 11:08:23 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002258164 Vs 11:08:24 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:08:33 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002253767 Vs 11:08:43 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002258585 Vs 11:08:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002255951 +- 0.000000156 Vs 11:08:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002255951 +- 0.000000156 Vs BL = 0.02255951 +- 0.00000156 Tm 11:08:43 Integrated Voltage Measurement... 11:08:44 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:08:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001502164 Vs 11:09:03 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001508131 Vs 11:09:04 Magnet Current for MAIN, Imag = 39.9604 A Vtrans = 0.399543 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:09:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001502789 Vs 11:09:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001507672 Vs 11:09:23 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:09:32 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001503498 Vs 11:09:41 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001506822 Vs 11:09:42 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:09:51 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001503555 Vs 11:10:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001506755 Vs 11:10:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001505173 +- 0.000000033 Vs 11:10:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001505173 +- 0.000000033 Vs BL = 0.01505173 +- 0.00000033 Tm 11:10:00 Integrated Voltage Measurement... 11:10:02 Magnet Current for MAIN, Imag = 39.9610 A Vtrans = 0.399549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:10:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000755443 Vs 11:10:21 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000759447 Vs 11:10:22 Magnet Current for MAIN, Imag = 39.9607 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:10:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000755109 Vs 11:10:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000759871 Vs 11:10:41 Magnet Current for MAIN, Imag = 39.9605 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:10:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000754430 Vs 11:10:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000759814 Vs 11:11:00 Magnet Current for MAIN, Imag = 39.9607 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:11:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000754217 Vs 11:11:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000759775 Vs 11:11:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000757263 +- 0.000000210 Vs 11:11:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000757263 +- 0.000000210 Vs BL = 0.00757263 +- 0.00000210 Tm 11:11:18 Integrated Voltage Measurement... 11:11:20 Magnet Current for MAIN, Imag = 39.9607 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:11:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000741732 Vs 11:11:39 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000737178 Vs 11:11:40 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:11:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000741037 Vs 11:11:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000737874 Vs 11:11:59 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:12:08 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000741472 Vs 11:12:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000737083 Vs 11:12:18 Magnet Current for MAIN, Imag = 39.9603 A Vtrans = 0.399542 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:12:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000741771 Vs 11:12:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000736983 Vs 11:12:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000739391 +- 0.000000073 Vs 11:12:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000739391 +- 0.000000073 Vs BL = -0.00739391 +- 0.00000073 Tm 11:12:37 Integrated Voltage Measurement... 11:12:38 Magnet Current for MAIN, Imag = 39.9605 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:12:48 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001491459 Vs 11:12:57 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001485564 Vs 11:12:58 Magnet Current for MAIN, Imag = 39.9607 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:13:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001489883 Vs 11:13:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001485738 Vs 11:13:17 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:13:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001490875 Vs 11:13:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001485289 Vs 11:13:36 Magnet Current for MAIN, Imag = 39.9605 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:13:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001491034 Vs 11:13:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001486099 Vs 11:13:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001488242 +- 0.000000312 Vs 11:13:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001488242 +- 0.000000312 Vs BL = -0.01488242 +- 0.00000312 Tm 11:13:55 Integrated Voltage Measurement... 11:13:56 Magnet Current for MAIN, Imag = 39.9607 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:14:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002239163 Vs 11:14:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002235389 Vs 11:14:16 Magnet Current for MAIN, Imag = 39.9603 A Vtrans = 0.399542 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:14:25 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002238983 Vs 11:14:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002235494 Vs 11:14:35 Magnet Current for MAIN, Imag = 39.9607 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:14:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002239862 Vs 11:14:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002235147 Vs 11:14:54 Magnet Current for MAIN, Imag = 39.9605 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:15:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002239820 Vs 11:15:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002234979 Vs 11:15:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002237355 +- 0.000000105 Vs 11:15:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002237355 +- 0.000000105 Vs BL = -0.02237355 +- 0.00000105 Tm 11:15:16 Position moved: 0.000000 m 11:15:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00009 0.00000 1 -0.74869 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.02256 0.00000 0.02255 0.00001 -0.0200000 0.01505 0.00000 0.01506 -0.00001 -0.0100000 0.00757 0.00000 0.00758 -0.00000 0.0100000 -0.00739 0.00000 -0.00740 0.00000 0.0200000 -0.01488 0.00000 -0.01488 0.00000 0.0300000 -0.02237 0.00000 -0.02237 -0.00000 11:15:16 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.02256 0.00000 -0.0200 0.01505 0.00000 -0.0100 0.00757 0.00000 0.0100 -0.00739 0.00000 0.0200 -0.01488 0.00000 0.0300 -0.02237 0.00000 SL = -0.7486930 +- 0.0000312 Tm^2/m^n 11:15:17 Quadrupole Strength Calculation Check Slope = -0.748693 Tm/m, Inter = 0.000089 Tm, Sig_slope = 0.000151 Tm/m, Est_sig = 0.000008 Tm GL = -0.748693 +- 0.000151 T 11:15:17 Magnet Strength Measurement Harmonic Number = 2 SL = -0.7486930 +- 0.0000312 Tm^2/m^n 11:15:19 Position moved: 0.000000 m 11:15:19 Magnet system MAIN current ramping to 60.0000 A... 11:15:43 Magnet Current for MAIN, Imag = 59.9373 A Vtrans = 0.599312 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:15:43 Main (V) Voltage Measurement, V = 2.048822 V 11:15:44 Temperature Measurement, Probe Number = 0, T = 28.178000 C 11:15:48 Temperature Measurement, Probe Number = 1, T = 28.498000 C 11:15:49 Temperature Measurement, Probe Number = 2, T = 28.450000 C 11:15:50 Temperature Measurement, Probe Number = 3, T = 28.442000 C 11:15:51 Temperature Measurement, Probe Number = 4, T = 21.948000 C 11:15:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355103 V 11:15:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355103 (V, A, ohm, ...), Measured Value = 28.820879 (C, atm, Hz, ...) 11:15:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.302875 V 11:15:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302875 (V, A, ohm, ...), Measured Value = 28.095482 (C, atm, Hz, ...) 11:15:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.675116 V 11:15:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.675116 (V, A, ohm, ...), Measured Value = 125.633678 (C, atm, Hz, ...) 11:15:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097055 V 11:15:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097055 (V, A, ohm, ...), Measured Value = 7.279102 (C, atm, Hz, ...) 11:15:57 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003254 V 11:15:57 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003254 (V, A, ohm, ...), Measured Value = 3.253525 (C, atm, Hz, ...) 11:15:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.94 P1 = Main (V), Value = 2.05 P2 = Top Right Coil, Value = 28.18 P3 = Bottom Right Coil, Value = 28.50 P4 = Top Left Coil, Value = 28.45 P5 = Bottom Left Coil, Value = 28.44 P6 = Ambient, Value = 21.95 P7 = Supply Temp(C), Value = 28.82 P8 = Return Temp(C), Value = 28.10 P9 = Supply Pres(psi), Value = 125.63 P10 = Return Pres(psi), Value = 7.28 P11 = Flow Rate(gpm), Value = 3.25 11:15:57 Magnetic Field Measurement Measuring the magnet strength... 11:15:57 Integrated Voltage Measurement... 11:15:58 Magnet Current for MAIN, Imag = 59.9374 A Vtrans = 0.599313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:16:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003366855 Vs 11:16:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003371748 Vs 11:16:19 Magnet Current for MAIN, Imag = 59.9369 A Vtrans = 0.599308 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:16:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003367149 Vs 11:16:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003372241 Vs 11:16:38 Magnet Current for MAIN, Imag = 59.9382 A Vtrans = 0.599321 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:16:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003367432 Vs 11:16:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003372091 Vs 11:16:57 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599316 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:17:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003367103 Vs 11:17:15 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003372338 Vs 11:17:15 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003369620 +- 0.000000185 Vs 11:17:15 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003369620 +- 0.000000185 Vs BL = 0.03369620 +- 0.00000185 Tm 11:17:15 Integrated Voltage Measurement... 11:17:16 Magnet Current for MAIN, Imag = 59.9374 A Vtrans = 0.599313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:17:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002246354 Vs 11:17:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002252379 Vs 11:17:37 Magnet Current for MAIN, Imag = 59.9371 A Vtrans = 0.599310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:17:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002246435 Vs 11:17:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002252531 Vs 11:17:56 Magnet Current for MAIN, Imag = 59.9375 A Vtrans = 0.599314 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:18:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002246343 Vs 11:18:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002252192 Vs 11:18:15 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599316 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:18:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002247031 Vs 11:18:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002250730 Vs 11:18:33 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002249250 +- 0.000000226 Vs 11:18:33 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002249250 +- 0.000000226 Vs BL = 0.02249250 +- 0.00000226 Tm 11:18:33 Integrated Voltage Measurement... 11:18:34 Magnet Current for MAIN, Imag = 59.9374 A Vtrans = 0.599313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:18:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001130433 Vs 11:18:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001132463 Vs 11:18:55 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599316 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:19:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001130018 Vs 11:19:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001133143 Vs 11:19:14 Magnet Current for MAIN, Imag = 59.9373 A Vtrans = 0.599312 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:19:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001130441 Vs 11:19:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001133493 Vs 11:19:33 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599316 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:19:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001129488 Vs 11:19:52 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001133189 Vs 11:19:52 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001131583 +- 0.000000237 Vs 11:19:52 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001131583 +- 0.000000237 Vs BL = 0.01131583 +- 0.00000237 Tm 11:19:52 Integrated Voltage Measurement... 11:19:53 Magnet Current for MAIN, Imag = 59.9374 A Vtrans = 0.599313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:20:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001105003 Vs 11:20:12 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001100722 Vs 11:20:13 Magnet Current for MAIN, Imag = 59.9380 A Vtrans = 0.599319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:20:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001105383 Vs 11:20:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001099872 Vs 11:20:32 Magnet Current for MAIN, Imag = 59.9378 A Vtrans = 0.599317 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:20:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001105492 Vs 11:20:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001099907 Vs 11:20:51 Magnet Current for MAIN, Imag = 59.9378 A Vtrans = 0.599317 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:21:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001105295 Vs 11:21:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001099866 Vs 11:21:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001102692 +- 0.000000107 Vs 11:21:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001102692 +- 0.000000107 Vs BL = -0.01102692 +- 0.00000107 Tm 11:21:10 Integrated Voltage Measurement... 11:21:11 Magnet Current for MAIN, Imag = 59.9379 A Vtrans = 0.599318 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:21:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002223969 Vs 11:21:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002217348 Vs 11:21:31 Magnet Current for MAIN, Imag = 59.9382 A Vtrans = 0.599321 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:21:40 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002224345 Vs 11:21:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002217726 Vs 11:21:50 Magnet Current for MAIN, Imag = 59.9380 A Vtrans = 0.599319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:21:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002223758 Vs 11:22:08 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002218566 Vs 11:22:09 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599316 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:22:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002222997 Vs 11:22:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002219180 Vs 11:22:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002220986 +- 0.000000194 Vs 11:22:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002220986 +- 0.000000194 Vs BL = -0.02220986 +- 0.00000194 Tm 11:22:28 Integrated Voltage Measurement... 11:22:29 Magnet Current for MAIN, Imag = 59.9378 A Vtrans = 0.599317 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:22:39 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003342233 Vs 11:22:48 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003337650 Vs 11:22:49 Magnet Current for MAIN, Imag = 59.9383 A Vtrans = 0.599322 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:22:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003342596 Vs 11:23:07 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003337631 Vs 11:23:08 Magnet Current for MAIN, Imag = 59.9379 A Vtrans = 0.599318 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:23:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003342409 Vs 11:23:27 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003337368 Vs 11:23:28 Magnet Current for MAIN, Imag = 59.9380 A Vtrans = 0.599319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:23:37 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003341725 Vs 11:23:46 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003338308 Vs 11:23:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003339990 +- 0.000000085 Vs 11:23:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003339990 +- 0.000000085 Vs BL = -0.03339990 +- 0.00000085 Tm 11:23:50 Position moved: 0.000000 m 11:23:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00014 0.00000 1 -1.11798 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.03370 0.00000 0.03368 0.00001 -0.0200000 0.02249 0.00000 0.02250 -0.00001 -0.0100000 0.01132 0.00000 0.01132 -0.00001 0.0100000 -0.01103 0.00000 -0.01104 0.00001 0.0200000 -0.02221 0.00000 -0.02222 0.00001 0.0300000 -0.03340 0.00000 -0.03339 -0.00000 11:23:50 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.03370 0.00000 -0.0200 0.02249 0.00000 -0.0100 0.01132 0.00000 0.0100 -0.01103 0.00000 0.0200 -0.02221 0.00000 0.0300 -0.03340 0.00000 SL = -1.1179849 +- 0.0000319 Tm^2/m^n 11:23:50 Quadrupole Strength Calculation Check Slope = -1.117985 Tm/m, Inter = 0.000145 Tm, Sig_slope = 0.000207 Tm/m, Est_sig = 0.000011 Tm GL = -1.117985 +- 0.000207 T 11:23:50 Magnet Strength Measurement Harmonic Number = 2 SL = -1.1179849 +- 0.0000319 Tm^2/m^n 11:23:52 Position moved: 0.000000 m 11:23:52 Magnet system MAIN current ramping to 80.0000 A... 11:24:16 Magnet Current for MAIN, Imag = 80.0047 A Vtrans = 0.799986 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:24:17 Main (V) Voltage Measurement, V = 2.735558 V 11:24:17 Temperature Measurement, Probe Number = 0, T = 28.271000 C 11:24:21 Temperature Measurement, Probe Number = 1, T = 28.584000 C 11:24:22 Temperature Measurement, Probe Number = 2, T = 28.511000 C 11:24:23 Temperature Measurement, Probe Number = 3, T = 28.537000 C 11:24:24 Temperature Measurement, Probe Number = 4, T = 22.146000 C 11:24:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355785 V 11:24:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355785 (V, A, ohm, ...), Measured Value = 28.830342 (C, atm, Hz, ...) 11:24:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.304836 V 11:24:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.304836 (V, A, ohm, ...), Measured Value = 28.122722 (C, atm, Hz, ...) 11:24:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663673 V 11:24:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663673 (V, A, ohm, ...), Measured Value = 124.775512 (C, atm, Hz, ...) 11:24:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096155 V 11:24:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096155 (V, A, ohm, ...), Measured Value = 7.211610 (C, atm, Hz, ...) 11:24:31 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003229 V 11:24:31 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003229 (V, A, ohm, ...), Measured Value = 3.228626 (C, atm, Hz, ...) 11:24:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.00 P1 = Main (V), Value = 2.74 P2 = Top Right Coil, Value = 28.27 P3 = Bottom Right Coil, Value = 28.58 P4 = Top Left Coil, Value = 28.51 P5 = Bottom Left Coil, Value = 28.54 P6 = Ambient, Value = 22.15 P7 = Supply Temp(C), Value = 28.83 P8 = Return Temp(C), Value = 28.12 P9 = Supply Pres(psi), Value = 124.78 P10 = Return Pres(psi), Value = 7.21 P11 = Flow Rate(gpm), Value = 3.23 11:24:31 Magnetic Field Measurement Measuring the magnet strength... 11:24:31 Integrated Voltage Measurement... 11:24:32 Magnet Current for MAIN, Imag = 80.0054 A Vtrans = 0.799993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:24:42 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004488368 Vs 11:24:51 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004491426 Vs 11:24:52 Magnet Current for MAIN, Imag = 80.0054 A Vtrans = 0.799993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:25:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004488131 Vs 11:25:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004492204 Vs 11:25:11 Magnet Current for MAIN, Imag = 80.0056 A Vtrans = 0.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:25:20 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004488498 Vs 11:25:29 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004491980 Vs 11:25:30 Magnet Current for MAIN, Imag = 80.0055 A Vtrans = 0.799994 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:25:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004487762 Vs 11:25:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004492920 Vs 11:25:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004490161 +- 0.000000165 Vs 11:25:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004490161 +- 0.000000165 Vs BL = 0.04490161 +- 0.00000165 Tm 11:25:49 Integrated Voltage Measurement... 11:25:50 Magnet Current for MAIN, Imag = 80.0065 A Vtrans = 0.800004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:26:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002994614 Vs 11:26:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003000380 Vs 11:26:10 Magnet Current for MAIN, Imag = 80.0054 A Vtrans = 0.799993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:26:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002994818 Vs 11:26:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003000477 Vs 11:26:29 Magnet Current for MAIN, Imag = 80.0041 A Vtrans = 0.799980 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:26:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002994353 Vs 11:26:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003000787 Vs 11:26:48 Magnet Current for MAIN, Imag = 80.0056 A Vtrans = 0.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:26:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002995087 Vs 11:27:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002999566 Vs 11:27:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002997510 +- 0.000000119 Vs 11:27:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002997510 +- 0.000000119 Vs BL = 0.02997510 +- 0.00000119 Tm 11:27:07 Integrated Voltage Measurement... 11:27:08 Magnet Current for MAIN, Imag = 80.0060 A Vtrans = 0.799999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:27:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001506341 Vs 11:27:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001510414 Vs 11:27:28 Magnet Current for MAIN, Imag = 80.0056 A Vtrans = 0.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:27:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001506265 Vs 11:27:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001510850 Vs 11:27:47 Magnet Current for MAIN, Imag = 80.0060 A Vtrans = 0.799999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:27:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001505962 Vs 11:28:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001511090 Vs 11:28:06 Magnet Current for MAIN, Imag = 80.0054 A Vtrans = 0.799993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:28:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001506518 Vs 11:28:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001510859 Vs 11:28:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001508537 +- 0.000000111 Vs 11:28:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001508537 +- 0.000000111 Vs BL = 0.01508537 +- 0.00000111 Tm 11:28:25 Integrated Voltage Measurement... 11:28:26 Magnet Current for MAIN, Imag = 80.0046 A Vtrans = 0.799985 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:28:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001471793 Vs 11:28:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001466133 Vs 11:28:46 Magnet Current for MAIN, Imag = 80.0056 A Vtrans = 0.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:28:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001471172 Vs 11:29:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001467061 Vs 11:29:05 Magnet Current for MAIN, Imag = 80.0050 A Vtrans = 0.799989 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:29:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001470607 Vs 11:29:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001467058 Vs 11:29:24 Magnet Current for MAIN, Imag = 80.0061 A Vtrans = 0.800000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:29:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001470846 Vs 11:29:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001467730 Vs 11:29:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001469050 +- 0.000000170 Vs 11:29:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001469050 +- 0.000000170 Vs BL = -0.01469050 +- 0.00000170 Tm 11:29:43 Integrated Voltage Measurement... 11:29:44 Magnet Current for MAIN, Imag = 80.0064 A Vtrans = 0.800003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:29:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002958839 Vs 11:30:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002957268 Vs 11:30:04 Magnet Current for MAIN, Imag = 80.0040 A Vtrans = 0.799979 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:30:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002958924 Vs 11:30:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002957182 Vs 11:30:23 Magnet Current for MAIN, Imag = 80.0046 A Vtrans = 0.799985 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:30:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002960016 Vs 11:30:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002955840 Vs 11:30:43 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800061 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:30:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002960705 Vs 11:31:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002955798 Vs 11:31:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002958071 +- 0.000000116 Vs 11:31:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002958071 +- 0.000000116 Vs BL = -0.02958071 +- 0.00000116 Tm 11:31:01 Integrated Voltage Measurement... 11:31:02 Magnet Current for MAIN, Imag = 80.0050 A Vtrans = 0.799989 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:31:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004451330 Vs 11:31:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004446382 Vs 11:31:22 Magnet Current for MAIN, Imag = 80.0028 A Vtrans = 0.799967 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:31:31 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004451872 Vs 11:31:40 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004446859 Vs 11:31:41 Magnet Current for MAIN, Imag = 80.0051 A Vtrans = 0.799990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:31:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004451368 Vs 11:31:59 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004447369 Vs 11:32:00 Magnet Current for MAIN, Imag = 80.0065 A Vtrans = 0.800004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:32:10 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004452619 Vs 11:32:19 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004447603 Vs 11:32:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004449425 +- 0.000000448 Vs 11:32:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004449425 +- 0.000000448 Vs BL = -0.04449425 +- 0.00000448 Tm 11:32:23 Position moved: 0.000000 m 11:32:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00020 0.00000 1 -1.48955 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.04490 0.00000 0.04489 0.00002 -0.0200000 0.02998 0.00000 0.02999 -0.00002 -0.0100000 0.01509 0.00000 0.01509 -0.00001 0.0100000 -0.01469 0.00000 -0.01470 0.00001 0.0200000 -0.02958 0.00000 -0.02959 0.00001 0.0300000 -0.04449 0.00000 -0.04449 -0.00001 11:32:23 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.04490 0.00000 -0.0200 0.02998 0.00000 -0.0100 0.01509 0.00000 0.0100 -0.01469 0.00000 0.0200 -0.02958 0.00000 0.0300 -0.04449 0.00000 SL = -1.4895539 +- 0.0000530 Tm^2/m^n 11:32:23 Quadrupole Strength Calculation Check Slope = -1.489554 Tm/m, Inter = 0.000199 Tm, Sig_slope = 0.000263 Tm/m, Est_sig = 0.000014 Tm GL = -1.489554 +- 0.000263 T 11:32:23 Magnet Strength Measurement Harmonic Number = 2 SL = -1.4895539 +- 0.0000530 Tm^2/m^n 11:32:25 Position moved: 0.000000 m 11:32:25 Magnet system MAIN current ramping to 100.0000 A... 11:32:49 Magnet Current for MAIN, Imag = 99.9919 A Vtrans = 0.999858 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:32:50 Main (V) Voltage Measurement, V = 3.419256 V 11:32:50 Temperature Measurement, Probe Number = 0, T = 28.345000 C 11:32:54 Temperature Measurement, Probe Number = 1, T = 28.679000 C 11:32:55 Temperature Measurement, Probe Number = 2, T = 28.566000 C 11:32:56 Temperature Measurement, Probe Number = 3, T = 28.623000 C 11:32:57 Temperature Measurement, Probe Number = 4, T = 22.301000 C 11:32:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.356285 V 11:32:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356285 (V, A, ohm, ...), Measured Value = 28.837297 (C, atm, Hz, ...) 11:32:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.310827 V 11:32:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310827 (V, A, ohm, ...), Measured Value = 28.205926 (C, atm, Hz, ...) 11:32:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.647563 V 11:32:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.647563 (V, A, ohm, ...), Measured Value = 123.567195 (C, atm, Hz, ...) 11:33:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096123 V 11:33:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096123 (V, A, ohm, ...), Measured Value = 7.209225 (C, atm, Hz, ...) 11:33:04 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003238 V 11:33:04 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003238 (V, A, ohm, ...), Measured Value = 3.238232 (C, atm, Hz, ...) 11:33:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 99.99 P1 = Main (V), Value = 3.42 P2 = Top Right Coil, Value = 28.34 P3 = Bottom Right Coil, Value = 28.68 P4 = Top Left Coil, Value = 28.57 P5 = Bottom Left Coil, Value = 28.62 P6 = Ambient, Value = 22.30 P7 = Supply Temp(C), Value = 28.84 P8 = Return Temp(C), Value = 28.21 P9 = Supply Pres(psi), Value = 123.57 P10 = Return Pres(psi), Value = 7.21 P11 = Flow Rate(gpm), Value = 3.24 11:33:04 Magnetic Field Measurement Measuring the magnet strength... 11:33:04 Integrated Voltage Measurement... 11:33:05 Magnet Current for MAIN, Imag = 99.9750 A Vtrans = 0.999689 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:33:15 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005604433 Vs 11:33:24 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005610341 Vs 11:33:25 Magnet Current for MAIN, Imag = 99.9831 A Vtrans = 0.999770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:33:34 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005602965 Vs 11:33:43 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005609346 Vs 11:33:44 Magnet Current for MAIN, Imag = 99.9740 A Vtrans = 0.999679 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:33:53 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005604847 Vs 11:34:03 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005611134 Vs 11:34:04 Magnet Current for MAIN, Imag = 99.9844 A Vtrans = 0.999783 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:34:13 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005603819 Vs 11:34:22 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005610648 Vs 11:34:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005607191 +- 0.000000662 Vs 11:34:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005607191 +- 0.000000662 Vs BL = 0.05607191 +- 0.00000662 Tm 11:34:22 Integrated Voltage Measurement... 11:34:23 Magnet Current for MAIN, Imag = 99.9852 A Vtrans = 0.999791 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:34:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003740873 Vs 11:34:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003747119 Vs 11:34:43 Magnet Current for MAIN, Imag = 99.9820 A Vtrans = 0.999759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:34:52 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003741002 Vs 11:35:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003747283 Vs 11:35:02 Magnet Current for MAIN, Imag = 99.9838 A Vtrans = 0.999777 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:35:11 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003740244 Vs 11:35:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003745880 Vs 11:35:22 Magnet Current for MAIN, Imag = 99.9713 A Vtrans = 0.999652 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:35:31 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003741044 Vs 11:35:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003746158 Vs 11:35:40 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003743700 +- 0.000000418 Vs 11:35:40 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003743700 +- 0.000000418 Vs BL = 0.03743700 +- 0.00000418 Tm 11:35:40 Integrated Voltage Measurement... 11:35:41 Magnet Current for MAIN, Imag = 99.9826 A Vtrans = 0.999765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:35:51 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001882172 Vs 11:36:00 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001885042 Vs 11:36:01 Magnet Current for MAIN, Imag = 99.9824 A Vtrans = 0.999763 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:36:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001882231 Vs 11:36:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001885251 Vs 11:36:20 Magnet Current for MAIN, Imag = 99.9863 A Vtrans = 0.999802 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:36:30 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001881715 Vs 11:36:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001885614 Vs 11:36:40 Magnet Current for MAIN, Imag = 99.9839 A Vtrans = 0.999778 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:36:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001881485 Vs 11:36:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001886012 Vs 11:36:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001883690 +- 0.000000058 Vs 11:36:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001883690 +- 0.000000058 Vs BL = 0.01883690 +- 0.00000058 Tm 11:36:58 Integrated Voltage Measurement... 11:36:59 Magnet Current for MAIN, Imag = 99.9820 A Vtrans = 0.999759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:37:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001835268 Vs 11:37:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001831593 Vs 11:37:19 Magnet Current for MAIN, Imag = 99.9848 A Vtrans = 0.999787 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:37:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001835985 Vs 11:37:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001831201 Vs 11:37:38 Magnet Current for MAIN, Imag = 99.9836 A Vtrans = 0.999775 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:37:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001836379 Vs 11:37:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001830850 Vs 11:37:58 Magnet Current for MAIN, Imag = 99.9824 A Vtrans = 0.999763 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:38:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001837118 Vs 11:38:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001829684 Vs 11:38:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001833510 +- 0.000000095 Vs 11:38:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001833510 +- 0.000000095 Vs BL = -0.01833510 +- 0.00000095 Tm 11:38:16 Integrated Voltage Measurement... 11:38:17 Magnet Current for MAIN, Imag = 99.9826 A Vtrans = 0.999765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:38:27 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003697137 Vs 11:38:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003689253 Vs 11:38:37 Magnet Current for MAIN, Imag = 99.9820 A Vtrans = 0.999759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:38:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003696912 Vs 11:38:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003690221 Vs 11:38:57 Magnet Current for MAIN, Imag = 99.9824 A Vtrans = 0.999763 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:39:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003697185 Vs 11:39:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003690143 Vs 11:39:16 Magnet Current for MAIN, Imag = 99.9841 A Vtrans = 0.999780 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:39:25 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003696188 Vs 11:39:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003690197 Vs 11:39:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003693405 +- 0.000000214 Vs 11:39:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003693405 +- 0.000000214 Vs BL = -0.03693405 +- 0.00000214 Tm 11:39:34 Integrated Voltage Measurement... 11:39:35 Magnet Current for MAIN, Imag = 99.9850 A Vtrans = 0.999789 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:39:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005556899 Vs 11:39:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005551986 Vs 11:39:55 Magnet Current for MAIN, Imag = 99.9841 A Vtrans = 0.999780 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:40:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005556283 Vs 11:40:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005552362 Vs 11:40:15 Magnet Current for MAIN, Imag = 99.9807 A Vtrans = 0.999746 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:40:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005557048 Vs 11:40:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005552195 Vs 11:40:34 Magnet Current for MAIN, Imag = 99.9864 A Vtrans = 0.999803 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:40:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005557040 Vs 11:40:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005552328 Vs 11:40:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005554518 +- 0.000000143 Vs 11:40:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005554518 +- 0.000000143 Vs BL = -0.05554518 +- 0.00000143 Tm 11:40:56 Position moved: 0.000000 m 11:40:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00026 0.00000 1 -1.85988 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.05607 0.00001 0.05605 0.00002 -0.0200000 0.03744 0.00000 0.03745 -0.00002 -0.0100000 0.01884 0.00000 0.01885 -0.00002 0.0100000 -0.01834 0.00000 -0.01834 0.00001 0.0200000 -0.03693 0.00000 -0.03694 0.00001 0.0300000 -0.05555 0.00000 -0.05554 -0.00000 11:40:56 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.05607 0.00001 -0.0200 0.03744 0.00000 -0.0100 0.01884 0.00000 0.0100 -0.01834 0.00000 0.0200 -0.03693 0.00000 0.0300 -0.05555 0.00000 SL = -1.8598763 +- 0.0000800 Tm^2/m^n 11:40:56 Quadrupole Strength Calculation Check Slope = -1.859876 Tm/m, Inter = 0.000255 Tm, Sig_slope = 0.000315 Tm/m, Est_sig = 0.000017 Tm GL = -1.859876 +- 0.000315 T 11:40:56 Magnet Strength Measurement Harmonic Number = 2 SL = -1.8598763 +- 0.0000800 Tm^2/m^n 11:40:59 Position moved: 0.000000 m 11:40:59 Magnet system MAIN current ramping to 120.0000 A... 11:41:22 Magnet Current for MAIN, Imag = 119.9688 A Vtrans = 1.199626 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:41:23 Main (V) Voltage Measurement, V = 4.104448 V 11:41:24 Temperature Measurement, Probe Number = 0, T = 28.437000 C 11:41:28 Temperature Measurement, Probe Number = 1, T = 28.776000 C 11:41:29 Temperature Measurement, Probe Number = 2, T = 28.626000 C 11:41:30 Temperature Measurement, Probe Number = 3, T = 28.733000 C 11:41:30 Temperature Measurement, Probe Number = 4, T = 22.417000 C 11:41:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355888 V 11:41:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355888 (V, A, ohm, ...), Measured Value = 28.831771 (C, atm, Hz, ...) 11:41:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.317357 V 11:41:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317357 (V, A, ohm, ...), Measured Value = 28.296632 (C, atm, Hz, ...) 11:41:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666207 V 11:41:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666207 (V, A, ohm, ...), Measured Value = 124.965502 (C, atm, Hz, ...) 11:41:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096844 V 11:41:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096844 (V, A, ohm, ...), Measured Value = 7.263277 (C, atm, Hz, ...) 11:41:37 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003236 V 11:41:37 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003236 (V, A, ohm, ...), Measured Value = 3.235615 (C, atm, Hz, ...) 11:41:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 119.97 P1 = Main (V), Value = 4.10 P2 = Top Right Coil, Value = 28.44 P3 = Bottom Right Coil, Value = 28.78 P4 = Top Left Coil, Value = 28.63 P5 = Bottom Left Coil, Value = 28.73 P6 = Ambient, Value = 22.42 P7 = Supply Temp(C), Value = 28.83 P8 = Return Temp(C), Value = 28.30 P9 = Supply Pres(psi), Value = 124.97 P10 = Return Pres(psi), Value = 7.26 P11 = Flow Rate(gpm), Value = 3.24 11:41:37 Magnetic Field Measurement Measuring the magnet strength... 11:41:37 Integrated Voltage Measurement... 11:41:38 Magnet Current for MAIN, Imag = 119.9695 A Vtrans = 1.199634 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:41:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006723085 Vs 11:41:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006728534 Vs 11:41:58 Magnet Current for MAIN, Imag = 119.9693 A Vtrans = 1.199632 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:42:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006721999 Vs 11:42:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006729252 Vs 11:42:18 Magnet Current for MAIN, Imag = 119.9695 A Vtrans = 1.199634 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:42:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006722755 Vs 11:42:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006728081 Vs 11:42:37 Magnet Current for MAIN, Imag = 119.9658 A Vtrans = 1.199597 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:42:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006722935 Vs 11:42:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006726896 Vs 11:42:55 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006725442 +- 0.000000334 Vs 11:42:55 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006725442 +- 0.000000334 Vs BL = 0.06725442 +- 0.00000334 Tm 11:42:55 Integrated Voltage Measurement... 11:42:56 Magnet Current for MAIN, Imag = 119.9795 A Vtrans = 1.199734 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:43:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004489719 Vs 11:43:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004490951 Vs 11:43:16 Magnet Current for MAIN, Imag = 119.9670 A Vtrans = 1.199609 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:43:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004490166 Vs 11:43:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004490476 Vs 11:43:36 Magnet Current for MAIN, Imag = 119.9673 A Vtrans = 1.199612 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:43:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004489469 Vs 11:43:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004491120 Vs 11:43:55 Magnet Current for MAIN, Imag = 119.9682 A Vtrans = 1.199621 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:44:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004488720 Vs 11:44:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004491744 Vs 11:44:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004490296 +- 0.000000039 Vs 11:44:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004490296 +- 0.000000039 Vs BL = 0.04490296 +- 0.00000039 Tm 11:44:13 Integrated Voltage Measurement... 11:44:14 Magnet Current for MAIN, Imag = 119.9679 A Vtrans = 1.199618 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:44:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002259197 Vs 11:44:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002261249 Vs 11:44:34 Magnet Current for MAIN, Imag = 119.9610 A Vtrans = 1.199549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:44:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002258386 Vs 11:44:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002261672 Vs 11:44:54 Magnet Current for MAIN, Imag = 119.9680 A Vtrans = 1.199619 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:45:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002256954 Vs 11:45:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002262420 Vs 11:45:13 Magnet Current for MAIN, Imag = 119.9686 A Vtrans = 1.199625 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:45:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002256764 Vs 11:45:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002263757 Vs 11:45:31 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002260050 +- 0.000000227 Vs 11:45:31 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002260050 +- 0.000000227 Vs BL = 0.02260050 +- 0.00000227 Tm 11:45:31 Integrated Voltage Measurement... 11:45:32 Magnet Current for MAIN, Imag = 119.9663 A Vtrans = 1.199602 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:45:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002201590 Vs 11:45:51 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002196183 Vs 11:45:52 Magnet Current for MAIN, Imag = 119.9677 A Vtrans = 1.199616 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:46:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002201459 Vs 11:46:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002195718 Vs 11:46:12 Magnet Current for MAIN, Imag = 119.9673 A Vtrans = 1.199612 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:46:21 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002201590 Vs 11:46:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002196813 Vs 11:46:31 Magnet Current for MAIN, Imag = 119.9665 A Vtrans = 1.199604 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:46:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002201679 Vs 11:46:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002195806 Vs 11:46:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002198855 +- 0.000000226 Vs 11:46:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002198855 +- 0.000000226 Vs BL = -0.02198855 +- 0.00000226 Tm 11:46:49 Integrated Voltage Measurement... 11:46:50 Magnet Current for MAIN, Imag = 119.9680 A Vtrans = 1.199619 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:47:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004431474 Vs 11:47:09 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004426081 Vs 11:47:10 Magnet Current for MAIN, Imag = 119.9673 A Vtrans = 1.199612 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:47:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004431858 Vs 11:47:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004426431 Vs 11:47:30 Magnet Current for MAIN, Imag = 119.9676 A Vtrans = 1.199615 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:47:39 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004432131 Vs 11:47:48 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004426293 Vs 11:47:49 Magnet Current for MAIN, Imag = 119.9695 A Vtrans = 1.199634 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:47:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004431618 Vs 11:48:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004426301 Vs 11:48:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004429023 +- 0.000000169 Vs 11:48:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004429023 +- 0.000000169 Vs BL = -0.04429023 +- 0.00000169 Tm 11:48:07 Integrated Voltage Measurement... 11:48:08 Magnet Current for MAIN, Imag = 119.9676 A Vtrans = 1.199615 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:48:18 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006664140 Vs 11:48:28 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006658488 Vs 11:48:29 Magnet Current for MAIN, Imag = 119.9666 A Vtrans = 1.199605 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:48:38 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006664276 Vs 11:48:47 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006659125 Vs 11:48:48 Magnet Current for MAIN, Imag = 119.9676 A Vtrans = 1.199615 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:48:57 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006662889 Vs 11:49:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006660614 Vs 11:49:07 Magnet Current for MAIN, Imag = 119.9644 A Vtrans = 1.199583 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:49:16 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006662829 Vs 11:49:25 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006659835 Vs 11:49:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006661525 +- 0.000000202 Vs 11:49:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006661525 +- 0.000000202 Vs BL = -0.06661525 +- 0.00000202 Tm 11:49:29 Position moved: 0.000000 m 11:49:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00031 0.00000 1 -2.23066 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.06725 0.00000 0.06723 0.00002 -0.0200000 0.04490 0.00000 0.04492 -0.00002 -0.0100000 0.02260 0.00000 0.02262 -0.00002 0.0100000 -0.02199 0.00000 -0.02200 0.00001 0.0200000 -0.04429 0.00000 -0.04430 0.00001 0.0300000 -0.06662 0.00000 -0.06661 -0.00001 11:49:29 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.06725 0.00000 -0.0200 0.04490 0.00000 -0.0100 0.02260 0.00000 0.0100 -0.02199 0.00000 0.0200 -0.04429 0.00000 0.0300 -0.06662 0.00000 SL = -2.2306587 +- 0.0000451 Tm^2/m^n 11:49:29 Quadrupole Strength Calculation Check Slope = -2.230659 Tm/m, Inter = 0.000311 Tm, Sig_slope = 0.000370 Tm/m, Est_sig = 0.000020 Tm GL = -2.230659 +- 0.000370 T 11:49:29 Magnet Strength Measurement Harmonic Number = 2 SL = -2.2306587 +- 0.0000451 Tm^2/m^n 11:49:32 Position moved: 0.000000 m 11:49:32 Magnet system MAIN current ramping to 140.0000 A... 11:49:55 Magnet Current for MAIN, Imag = 139.9444 A Vtrans = 1.399383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006100 A 11:49:56 Main (V) Voltage Measurement, V = 4.790216 V 11:49:57 Temperature Measurement, Probe Number = 0, T = 28.589000 C 11:50:01 Temperature Measurement, Probe Number = 1, T = 28.904000 C 11:50:02 Temperature Measurement, Probe Number = 2, T = 28.739000 C 11:50:03 Temperature Measurement, Probe Number = 3, T = 28.919000 C 11:50:04 Temperature Measurement, Probe Number = 4, T = 22.614000 C 11:50:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355482 V 11:50:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355482 (V, A, ohm, ...), Measured Value = 28.826139 (C, atm, Hz, ...) 11:50:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.327779 V 11:50:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327779 (V, A, ohm, ...), Measured Value = 28.441375 (C, atm, Hz, ...) 11:50:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660873 V 11:50:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660873 (V, A, ohm, ...), Measured Value = 124.565498 (C, atm, Hz, ...) 11:50:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096403 V 11:50:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096403 (V, A, ohm, ...), Measured Value = 7.230195 (C, atm, Hz, ...) 11:50:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003198 V 11:50:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003198 (V, A, ohm, ...), Measured Value = 3.198380 (C, atm, Hz, ...) 11:50:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.94 P1 = Main (V), Value = 4.79 P2 = Top Right Coil, Value = 28.59 P3 = Bottom Right Coil, Value = 28.90 P4 = Top Left Coil, Value = 28.74 P5 = Bottom Left Coil, Value = 28.92 P6 = Ambient, Value = 22.61 P7 = Supply Temp(C), Value = 28.83 P8 = Return Temp(C), Value = 28.44 P9 = Supply Pres(psi), Value = 124.57 P10 = Return Pres(psi), Value = 7.23 P11 = Flow Rate(gpm), Value = 3.20 12:15:08 Position moved: 0.000000 m 12:15:11 Magnet Current for MAIN, Imag = -0.0047 A Vtrans = -0.000047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:12 Magnet Current for MAIN, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:13 Magnet Current for MAIN, Imag = -0.0044 A Vtrans = -0.000044 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:14 Magnet Current for MAIN, Imag = -0.0042 A Vtrans = -0.000042 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:14 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0043 +- 0.0003 A 12:15:20 Initial Zero Current Measurement for MAIN, Imag_zero = -0.00432 A 12:15:20 Ambient Measurement Device(s) Being Used, type = None 12:15:20 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 12:15:21 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:15:22 Ambient Measurement Device(s) Being Used, type = HP34970 12:15:22 Magnet system MAIN current ramping to 300.0000 A... 12:16:10 Magnet system MAIN current ramping to 0.0000 A... 12:16:59 Magnet system MAIN current ramping to 300.0000 A... 12:17:47 Magnet system MAIN current ramping to 0.0000 A... 12:18:36 Magnet system MAIN current ramping to 300.0000 A... 12:19:24 Magnet system MAIN current ramping to 0.0000 A... 12:20:15 Position moved: 0.000000 m 12:20:18 Magnet system MAIN current ramping to 140.0000 A... 12:20:52 Magnet Current for MAIN, Imag = 139.9455 A Vtrans = 1.399412 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:20:53 Main (V) Voltage Measurement, V = 4.791640 V 12:20:54 Temperature Measurement, Probe Number = 0, T = 28.902000 C 12:21:01 Temperature Measurement, Probe Number = 1, T = 29.176000 C 12:21:02 Temperature Measurement, Probe Number = 2, T = 28.974000 C 12:21:03 Temperature Measurement, Probe Number = 3, T = 29.165000 C 12:21:04 Temperature Measurement, Probe Number = 4, T = 23.286000 C 12:21:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.359477 V 12:21:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359477 (V, A, ohm, ...), Measured Value = 28.881625 (C, atm, Hz, ...) 12:21:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367603 V 12:21:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367603 (V, A, ohm, ...), Measured Value = 28.994486 (C, atm, Hz, ...) 12:21:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655789 V 12:21:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655789 (V, A, ohm, ...), Measured Value = 124.184175 (C, atm, Hz, ...) 12:21:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096831 V 12:21:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096831 (V, A, ohm, ...), Measured Value = 7.262325 (C, atm, Hz, ...) 12:21:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003223 V 12:21:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003223 (V, A, ohm, ...), Measured Value = 3.223013 (C, atm, Hz, ...) 12:21:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.95 P1 = Main (V), Value = 4.79 P2 = Top Right Coil, Value = 28.90 P3 = Bottom Right Coil, Value = 29.18 P4 = Top Left Coil, Value = 28.97 P5 = Bottom Left Coil, Value = 29.16 P6 = Ambient, Value = 23.29 P7 = Supply Temp(C), Value = 28.88 P8 = Return Temp(C), Value = 28.99 P9 = Supply Pres(psi), Value = 124.18 P10 = Return Pres(psi), Value = 7.26 P11 = Flow Rate(gpm), Value = 3.22 12:21:10 Magnetic Field Measurement Measuring the magnet strength... 12:21:10 Integrated Voltage Measurement... 12:21:11 Magnet Current for MAIN, Imag = 139.9432 A Vtrans = 1.399389 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:21:22 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007844028 Vs 12:21:31 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007850568 Vs 12:21:32 Magnet Current for MAIN, Imag = 139.9327 A Vtrans = 1.399283 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:21:41 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007844436 Vs 12:21:50 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007848707 Vs 12:21:51 Magnet Current for MAIN, Imag = 139.9451 A Vtrans = 1.399408 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:22:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007842747 Vs 12:22:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007848299 Vs 12:22:11 Magnet Current for MAIN, Imag = 139.9447 A Vtrans = 1.399404 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:22:20 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007845204 Vs 12:22:29 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007849563 Vs 12:22:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007846694 +- 0.000000746 Vs 12:22:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007846694 +- 0.000000746 Vs BL = 0.07846694 +- 0.00000746 Tm 12:22:29 Integrated Voltage Measurement... 12:22:30 Magnet Current for MAIN, Imag = 139.9385 A Vtrans = 1.399342 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:22:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005236306 Vs 12:22:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005241865 Vs 12:22:51 Magnet Current for MAIN, Imag = 139.9441 A Vtrans = 1.399398 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:23:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005236787 Vs 12:23:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005242391 Vs 12:23:10 Magnet Current for MAIN, Imag = 139.9422 A Vtrans = 1.399379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:23:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005234383 Vs 12:23:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005243590 Vs 12:23:30 Magnet Current for MAIN, Imag = 139.9456 A Vtrans = 1.399413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:23:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005236230 Vs 12:23:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005242596 Vs 12:23:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005239269 +- 0.000000243 Vs 12:23:48 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005239269 +- 0.000000243 Vs BL = 0.05239269 +- 0.00000243 Tm 12:23:48 Integrated Voltage Measurement... 12:23:49 Magnet Current for MAIN, Imag = 139.9439 A Vtrans = 1.399395 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:23:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002633571 Vs 12:24:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002640960 Vs 12:24:09 Magnet Current for MAIN, Imag = 139.9450 A Vtrans = 1.399407 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:24:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002634078 Vs 12:24:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002640095 Vs 12:24:29 Magnet Current for MAIN, Imag = 139.9436 A Vtrans = 1.399393 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:24:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002635284 Vs 12:24:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002639818 Vs 12:24:48 Magnet Current for MAIN, Imag = 139.9451 A Vtrans = 1.399408 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:24:57 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002635047 Vs 12:25:07 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002639438 Vs 12:25:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002637286 +- 0.000000167 Vs 12:25:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002637286 +- 0.000000167 Vs BL = 0.02637286 +- 0.00000167 Tm 12:25:07 Integrated Voltage Measurement... 12:25:08 Magnet Current for MAIN, Imag = 139.9446 A Vtrans = 1.399403 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:25:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002565996 Vs 12:25:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002562447 Vs 12:25:28 Magnet Current for MAIN, Imag = 139.9454 A Vtrans = 1.399411 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:25:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002566056 Vs 12:25:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002563138 Vs 12:25:48 Magnet Current for MAIN, Imag = 139.9442 A Vtrans = 1.399399 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:25:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002565254 Vs 12:26:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002563328 Vs 12:26:07 Magnet Current for MAIN, Imag = 139.9440 A Vtrans = 1.399397 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:26:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002565533 Vs 12:26:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002562458 Vs 12:26:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002564276 +- 0.000000215 Vs 12:26:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002564276 +- 0.000000215 Vs BL = -0.02564276 +- 0.00000215 Tm 12:26:25 Integrated Voltage Measurement... 12:26:26 Magnet Current for MAIN, Imag = 139.9430 A Vtrans = 1.399387 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:26:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005168022 Vs 12:26:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005164429 Vs 12:26:47 Magnet Current for MAIN, Imag = 139.9454 A Vtrans = 1.399411 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:26:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005168752 Vs 12:27:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005163716 Vs 12:27:06 Magnet Current for MAIN, Imag = 139.9445 A Vtrans = 1.399402 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:27:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005168584 Vs 12:27:25 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005163919 Vs 12:27:26 Magnet Current for MAIN, Imag = 139.9436 A Vtrans = 1.399393 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:27:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005168707 Vs 12:27:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005164944 Vs 12:27:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005166384 +- 0.000000255 Vs 12:27:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005166384 +- 0.000000255 Vs BL = -0.05166384 +- 0.00000255 Tm 12:27:44 Integrated Voltage Measurement... 12:27:45 Magnet Current for MAIN, Imag = 139.9442 A Vtrans = 1.399399 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:27:55 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007773687 Vs 12:28:04 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007768291 Vs 12:28:05 Magnet Current for MAIN, Imag = 139.9449 A Vtrans = 1.399406 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:28:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007774183 Vs 12:28:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007768894 Vs 12:28:25 Magnet Current for MAIN, Imag = 139.9449 A Vtrans = 1.399406 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:28:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007774694 Vs 12:28:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007766802 Vs 12:28:44 Magnet Current for MAIN, Imag = 139.9426 A Vtrans = 1.399383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:28:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007774394 Vs 12:29:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007767654 Vs 12:29:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007771075 +- 0.000000288 Vs 12:29:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007771075 +- 0.000000288 Vs BL = -0.07771075 +- 0.00000288 Tm 12:29:07 Position moved: 0.000000 m 12:29:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00037 0.00000 1 -2.60236 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.07847 0.00001 0.07844 0.00003 -0.0200000 0.05239 0.00000 0.05242 -0.00002 -0.0100000 0.02637 0.00000 0.02639 -0.00002 0.0100000 -0.02564 0.00000 -0.02565 0.00001 0.0200000 -0.05166 0.00000 -0.05168 0.00001 0.0300000 -0.07771 0.00000 -0.07770 -0.00001 12:29:07 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.07847 0.00001 -0.0200 0.05239 0.00000 -0.0100 0.02637 0.00000 0.0100 -0.02564 0.00000 0.0200 -0.05166 0.00000 0.0300 -0.07771 0.00000 SL = -2.6023634 +- 0.0000898 Tm^2/m^n 12:29:07 Quadrupole Strength Calculation Check Slope = -2.602363 Tm/m, Inter = 0.000369 Tm, Sig_slope = 0.000434 Tm/m, Est_sig = 0.000023 Tm GL = -2.602363 +- 0.000434 T 12:29:07 Magnet Strength Measurement Harmonic Number = 2 SL = -2.6023634 +- 0.0000898 Tm^2/m^n 12:29:09 Position moved: 0.000000 m 12:29:09 Magnet system MAIN current ramping to 160.0000 A... 12:29:33 Magnet Current for MAIN, Imag = 160.0222 A Vtrans = 1.600178 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:29:34 Main (V) Voltage Measurement, V = 5.482211 V 12:29:34 Temperature Measurement, Probe Number = 0, T = 28.835000 C 12:29:38 Temperature Measurement, Probe Number = 1, T = 29.169000 C 12:29:39 Temperature Measurement, Probe Number = 2, T = 28.985000 C 12:29:40 Temperature Measurement, Probe Number = 3, T = 29.194000 C 12:29:41 Temperature Measurement, Probe Number = 4, T = 23.417000 C 12:29:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.359485 V 12:29:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359485 (V, A, ohm, ...), Measured Value = 28.881731 (C, atm, Hz, ...) 12:29:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.364016 V 12:29:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.364016 (V, A, ohm, ...), Measured Value = 28.944667 (C, atm, Hz, ...) 12:29:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.643013 V 12:29:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.643013 (V, A, ohm, ...), Measured Value = 123.226005 (C, atm, Hz, ...) 12:29:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097517 V 12:29:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097517 (V, A, ohm, ...), Measured Value = 7.313798 (C, atm, Hz, ...) 12:29:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003213 V 12:29:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003213 (V, A, ohm, ...), Measured Value = 3.213049 (C, atm, Hz, ...) 12:29:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.02 P1 = Main (V), Value = 5.48 P2 = Top Right Coil, Value = 28.84 P3 = Bottom Right Coil, Value = 29.17 P4 = Top Left Coil, Value = 28.98 P5 = Bottom Left Coil, Value = 29.19 P6 = Ambient, Value = 23.42 P7 = Supply Temp(C), Value = 28.88 P8 = Return Temp(C), Value = 28.94 P9 = Supply Pres(psi), Value = 123.23 P10 = Return Pres(psi), Value = 7.31 P11 = Flow Rate(gpm), Value = 3.21 12:29:47 Magnetic Field Measurement Measuring the magnet strength... 12:29:47 Integrated Voltage Measurement... 12:29:49 Magnet Current for MAIN, Imag = 160.0233 A Vtrans = 1.600190 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:29:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.008967547 Vs 12:30:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.008974441 Vs 12:30:09 Magnet Current for MAIN, Imag = 160.0222 A Vtrans = 1.600178 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:30:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.008968108 Vs 12:30:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.008973432 Vs 12:30:28 Magnet Current for MAIN, Imag = 160.0214 A Vtrans = 1.600171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:30:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.008966703 Vs 12:30:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.008974208 Vs 12:30:48 Magnet Current for MAIN, Imag = 160.0225 A Vtrans = 1.600182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:30:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.008966284 Vs 12:31:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.008975626 Vs 12:31:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.008970794 +- 0.000000213 Vs 12:31:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.008970794 +- 0.000000213 Vs BL = 0.08970794 +- 0.00000213 Tm 12:31:06 Integrated Voltage Measurement... 12:31:07 Magnet Current for MAIN, Imag = 160.0211 A Vtrans = 1.600168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:31:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005985569 Vs 12:31:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005993191 Vs 12:31:28 Magnet Current for MAIN, Imag = 160.0230 A Vtrans = 1.600187 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:31:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005987118 Vs 12:31:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005993885 Vs 12:31:47 Magnet Current for MAIN, Imag = 160.0220 A Vtrans = 1.600177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:31:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005987445 Vs 12:32:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005992719 Vs 12:32:06 Magnet Current for MAIN, Imag = 160.0226 A Vtrans = 1.600183 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:32:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005987442 Vs 12:32:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005992885 Vs 12:32:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005990032 +- 0.000000408 Vs 12:32:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005990032 +- 0.000000408 Vs BL = 0.05990032 +- 0.00000408 Tm 12:32:25 Integrated Voltage Measurement... 12:32:26 Magnet Current for MAIN, Imag = 160.0219 A Vtrans = 1.600176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:32:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003011801 Vs 12:32:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003017204 Vs 12:32:47 Magnet Current for MAIN, Imag = 160.0214 A Vtrans = 1.600171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:32:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003012382 Vs 12:33:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003017970 Vs 12:33:06 Magnet Current for MAIN, Imag = 160.0229 A Vtrans = 1.600186 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:33:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003011837 Vs 12:33:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003018734 Vs 12:33:25 Magnet Current for MAIN, Imag = 160.0228 A Vtrans = 1.600185 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:33:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003011779 Vs 12:33:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003018355 Vs 12:33:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003015008 +- 0.000000302 Vs 12:33:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003015008 +- 0.000000302 Vs BL = 0.03015008 +- 0.00000302 Tm 12:33:44 Integrated Voltage Measurement... 12:33:45 Magnet Current for MAIN, Imag = 160.0241 A Vtrans = 1.600197 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:33:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002933671 Vs 12:34:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002928903 Vs 12:34:05 Magnet Current for MAIN, Imag = 160.0216 A Vtrans = 1.600173 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:34:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002931855 Vs 12:34:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002930117 Vs 12:34:25 Magnet Current for MAIN, Imag = 160.0239 A Vtrans = 1.600196 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:34:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002932488 Vs 12:34:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002930388 Vs 12:34:44 Magnet Current for MAIN, Imag = 160.0216 A Vtrans = 1.600173 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:34:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002932518 Vs 12:35:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002929702 Vs 12:35:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002931205 +- 0.000000172 Vs 12:35:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002931205 +- 0.000000172 Vs BL = -0.02931205 +- 0.00000172 Tm 12:35:02 Integrated Voltage Measurement... 12:35:03 Magnet Current for MAIN, Imag = 160.0226 A Vtrans = 1.600183 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:35:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005907504 Vs 12:35:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005903669 Vs 12:35:24 Magnet Current for MAIN, Imag = 160.0223 A Vtrans = 1.600180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:35:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005908610 Vs 12:35:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005902256 Vs 12:35:43 Magnet Current for MAIN, Imag = 160.0223 A Vtrans = 1.600180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:35:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005908467 Vs 12:36:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005900967 Vs 12:36:03 Magnet Current for MAIN, Imag = 160.0218 A Vtrans = 1.600174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:36:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005909737 Vs 12:36:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005900542 Vs 12:36:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005905219 +- 0.000000331 Vs 12:36:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005905219 +- 0.000000331 Vs BL = -0.05905219 +- 0.00000331 Tm 12:36:21 Integrated Voltage Measurement... 12:36:22 Magnet Current for MAIN, Imag = 160.0222 A Vtrans = 1.600178 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:36:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008887652 Vs 12:36:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008878519 Vs 12:36:43 Magnet Current for MAIN, Imag = 160.0225 A Vtrans = 1.600182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:36:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008888085 Vs 12:37:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008878343 Vs 12:37:02 Magnet Current for MAIN, Imag = 160.0222 A Vtrans = 1.600178 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:37:11 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008888042 Vs 12:37:20 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008878181 Vs 12:37:21 Magnet Current for MAIN, Imag = 160.0216 A Vtrans = 1.600173 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:37:31 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008888295 Vs 12:37:40 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008879858 Vs 12:37:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008883372 +- 0.000000410 Vs 12:37:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008883372 +- 0.000000410 Vs BL = -0.08883372 +- 0.00000410 Tm 12:37:44 Position moved: 0.000000 m 12:37:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00043 0.00000 1 -2.97497 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.08971 0.00000 0.08968 0.00003 -0.0200000 0.05990 0.00000 0.05993 -0.00003 -0.0100000 0.03015 0.00000 0.03018 -0.00003 0.0100000 -0.02931 0.00000 -0.02932 0.00001 0.0200000 -0.05905 0.00000 -0.05907 0.00002 0.0300000 -0.08883 0.00000 -0.08882 -0.00001 12:37:44 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.08971 0.00000 -0.0200 0.05990 0.00000 -0.0100 0.03015 0.00000 0.0100 -0.02931 0.00000 0.0200 -0.05905 0.00000 0.0300 -0.08883 0.00000 SL = -2.9749719 +- 0.0000633 Tm^2/m^n 12:37:44 Quadrupole Strength Calculation Check Slope = -2.974972 Tm/m, Inter = 0.000427 Tm, Sig_slope = 0.000523 Tm/m, Est_sig = 0.000028 Tm GL = -2.974972 +- 0.000523 T 12:37:44 Magnet Strength Measurement Harmonic Number = 2 SL = -2.9749719 +- 0.0000633 Tm^2/m^n 12:37:46 Position moved: 0.000000 m 12:37:46 Magnet system MAIN current ramping to 180.0000 A... 12:38:10 Magnet Current for MAIN, Imag = 179.9960 A Vtrans = 1.799916 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:38:11 Main (V) Voltage Measurement, V = 6.170346 V 12:38:12 Temperature Measurement, Probe Number = 0, T = 28.988000 C 12:38:15 Temperature Measurement, Probe Number = 1, T = 29.320000 C 12:38:16 Temperature Measurement, Probe Number = 2, T = 29.050000 C 12:38:17 Temperature Measurement, Probe Number = 3, T = 29.361000 C 12:38:18 Temperature Measurement, Probe Number = 4, T = 23.659000 C 12:38:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.359835 V 12:38:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359835 (V, A, ohm, ...), Measured Value = 28.886604 (C, atm, Hz, ...) 12:38:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370347 V 12:38:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370347 (V, A, ohm, ...), Measured Value = 29.032600 (C, atm, Hz, ...) 12:38:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660192 V 12:38:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660192 (V, A, ohm, ...), Measured Value = 124.514400 (C, atm, Hz, ...) 12:38:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097524 V 12:38:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097524 (V, A, ohm, ...), Measured Value = 7.314277 (C, atm, Hz, ...) 12:38:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003247 V 12:38:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003247 (V, A, ohm, ...), Measured Value = 3.247278 (C, atm, Hz, ...) 12:38:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.00 P1 = Main (V), Value = 6.17 P2 = Top Right Coil, Value = 28.99 P3 = Bottom Right Coil, Value = 29.32 P4 = Top Left Coil, Value = 29.05 P5 = Bottom Left Coil, Value = 29.36 P6 = Ambient, Value = 23.66 P7 = Supply Temp(C), Value = 28.89 P8 = Return Temp(C), Value = 29.03 P9 = Supply Pres(psi), Value = 124.51 P10 = Return Pres(psi), Value = 7.31 P11 = Flow Rate(gpm), Value = 3.25 12:38:25 Magnetic Field Measurement Measuring the magnet strength... 12:38:25 Integrated Voltage Measurement... 12:38:26 Magnet Current for MAIN, Imag = 179.9976 A Vtrans = 1.799933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:38:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010085812 Vs 12:38:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010092155 Vs 12:38:46 Magnet Current for MAIN, Imag = 179.9981 A Vtrans = 1.799938 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:38:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010084303 Vs 12:39:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010093049 Vs 12:39:06 Magnet Current for MAIN, Imag = 179.9967 A Vtrans = 1.799924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:39:15 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010087144 Vs 12:39:24 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010091601 Vs 12:39:25 Magnet Current for MAIN, Imag = 179.9975 A Vtrans = 1.799932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:39:34 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010088024 Vs 12:39:44 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010091551 Vs 12:39:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010089205 +- 0.000000417 Vs 12:39:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010089205 +- 0.000000417 Vs BL = 0.10089205 +- 0.00000417 Tm 12:39:44 Integrated Voltage Measurement... 12:39:45 Magnet Current for MAIN, Imag = 179.9975 A Vtrans = 1.799932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:39:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006734359 Vs 12:40:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006740115 Vs 12:40:05 Magnet Current for MAIN, Imag = 179.9967 A Vtrans = 1.799924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:40:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006735337 Vs 12:40:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006739274 Vs 12:40:25 Magnet Current for MAIN, Imag = 179.9960 A Vtrans = 1.799916 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:40:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006735178 Vs 12:40:43 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006738093 Vs 12:40:44 Magnet Current for MAIN, Imag = 179.9956 A Vtrans = 1.799913 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:40:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006735678 Vs 12:41:03 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006739103 Vs 12:41:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006737142 +- 0.000000297 Vs 12:41:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006737142 +- 0.000000297 Vs BL = 0.06737142 +- 0.00000297 Tm 12:41:03 Integrated Voltage Measurement... 12:41:04 Magnet Current for MAIN, Imag = 179.9979 A Vtrans = 1.799935 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:41:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003390611 Vs 12:41:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003392334 Vs 12:41:25 Magnet Current for MAIN, Imag = 179.9989 A Vtrans = 1.799946 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:41:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003389782 Vs 12:41:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003393564 Vs 12:41:44 Magnet Current for MAIN, Imag = 179.9974 A Vtrans = 1.799930 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:41:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003389004 Vs 12:42:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003393623 Vs 12:42:04 Magnet Current for MAIN, Imag = 179.9970 A Vtrans = 1.799927 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:42:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003389693 Vs 12:42:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003393106 Vs 12:42:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003391465 +- 0.000000133 Vs 12:42:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003391465 +- 0.000000133 Vs BL = 0.03391465 +- 0.00000133 Tm 12:42:22 Integrated Voltage Measurement... 12:42:23 Magnet Current for MAIN, Imag = 179.9990 A Vtrans = 1.799947 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:42:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003297085 Vs 12:42:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003296639 Vs 12:42:44 Magnet Current for MAIN, Imag = 179.9982 A Vtrans = 1.799939 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:42:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003296660 Vs 12:43:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003295961 Vs 12:43:04 Magnet Current for MAIN, Imag = 179.9961 A Vtrans = 1.799918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:43:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003297089 Vs 12:43:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003295589 Vs 12:43:23 Magnet Current for MAIN, Imag = 179.9971 A Vtrans = 1.799928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:43:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003296919 Vs 12:43:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003295134 Vs 12:43:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003296385 +- 0.000000301 Vs 12:43:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003296385 +- 0.000000301 Vs BL = -0.03296385 +- 0.00000301 Tm 12:43:42 Integrated Voltage Measurement... 12:43:43 Magnet Current for MAIN, Imag = 179.9953 A Vtrans = 1.799910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:43:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006642383 Vs 12:44:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006640733 Vs 12:44:03 Magnet Current for MAIN, Imag = 179.9960 A Vtrans = 1.799916 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:44:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006641751 Vs 12:44:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006640173 Vs 12:44:23 Magnet Current for MAIN, Imag = 179.9965 A Vtrans = 1.799921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:44:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006643517 Vs 12:44:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006639142 Vs 12:44:42 Magnet Current for MAIN, Imag = 179.9962 A Vtrans = 1.799919 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:44:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006643459 Vs 12:45:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006639999 Vs 12:45:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006641395 +- 0.000000287 Vs 12:45:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006641395 +- 0.000000287 Vs BL = -0.06641395 +- 0.00000287 Tm 12:45:01 Integrated Voltage Measurement... 12:45:02 Magnet Current for MAIN, Imag = 179.9967 A Vtrans = 1.799924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:45:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009994700 Vs 12:45:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009988057 Vs 12:45:22 Magnet Current for MAIN, Imag = 179.9985 A Vtrans = 1.799942 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:45:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009994098 Vs 12:45:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009987252 Vs 12:45:42 Magnet Current for MAIN, Imag = 179.9972 A Vtrans = 1.799929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:45:51 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009994781 Vs 12:46:00 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009987211 Vs 12:46:01 Magnet Current for MAIN, Imag = 179.9967 A Vtrans = 1.799924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:46:11 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009994679 Vs 12:46:20 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009986895 Vs 12:46:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009990959 +- 0.000000268 Vs 12:46:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.009990959 +- 0.000000268 Vs BL = -0.09990959 +- 0.00000268 Tm 12:46:24 Position moved: 0.000000 m 12:46:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00048 0.00000 1 -3.34591 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.10089 0.00000 0.10086 0.00003 -0.0200000 0.06737 0.00000 0.06740 -0.00003 -0.0100000 0.03391 0.00000 0.03394 -0.00003 0.0100000 -0.03296 0.00000 -0.03298 0.00001 0.0200000 -0.06641 0.00000 -0.06644 0.00002 0.0300000 -0.09991 0.00000 -0.09990 -0.00001 12:46:24 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.10089 0.00000 -0.0200 0.06737 0.00000 -0.0100 0.03391 0.00000 0.0100 -0.03296 0.00000 0.0200 -0.06641 0.00000 0.0300 -0.09991 0.00000 SL = -3.3459077 +- 0.0000619 Tm^2/m^n 12:46:24 Quadrupole Strength Calculation Check Slope = -3.345908 Tm/m, Inter = 0.000482 Tm, Sig_slope = 0.000557 Tm/m, Est_sig = 0.000029 Tm GL = -3.345908 +- 0.000557 T 12:46:24 Magnet Strength Measurement Harmonic Number = 2 SL = -3.3459077 +- 0.0000619 Tm^2/m^n 12:46:27 Position moved: 0.000000 m 12:46:27 Magnet system MAIN current ramping to 200.0000 A... 12:46:50 Magnet Current for MAIN, Imag = 199.9861 A Vtrans = 1.999817 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:46:51 Main (V) Voltage Measurement, V = 6.860001 V 12:46:52 Temperature Measurement, Probe Number = 0, T = 29.164000 C 12:46:56 Temperature Measurement, Probe Number = 1, T = 29.527000 C 12:46:57 Temperature Measurement, Probe Number = 2, T = 29.201000 C 12:46:57 Temperature Measurement, Probe Number = 3, T = 29.617000 C 12:46:58 Temperature Measurement, Probe Number = 4, T = 23.822000 C 12:46:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.359680 V 12:46:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359680 (V, A, ohm, ...), Measured Value = 28.884450 (C, atm, Hz, ...) 12:47:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.384881 V 12:47:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.384881 (V, A, ohm, ...), Measured Value = 29.234454 (C, atm, Hz, ...) 12:47:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.638448 V 12:47:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.638448 (V, A, ohm, ...), Measured Value = 122.883585 (C, atm, Hz, ...) 12:47:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098077 V 12:47:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098077 (V, A, ohm, ...), Measured Value = 7.355745 (C, atm, Hz, ...) 12:47:05 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003203 V 12:47:05 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003203 (V, A, ohm, ...), Measured Value = 3.203114 (C, atm, Hz, ...) 12:47:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = Main (V), Value = 6.86 P2 = Top Right Coil, Value = 29.16 P3 = Bottom Right Coil, Value = 29.53 P4 = Top Left Coil, Value = 29.20 P5 = Bottom Left Coil, Value = 29.62 P6 = Ambient, Value = 23.82 P7 = Supply Temp(C), Value = 28.88 P8 = Return Temp(C), Value = 29.23 P9 = Supply Pres(psi), Value = 122.88 P10 = Return Pres(psi), Value = 7.36 P11 = Flow Rate(gpm), Value = 3.20 12:47:05 Magnetic Field Measurement Measuring the magnet strength... 12:47:05 Integrated Voltage Measurement... 12:47:06 Magnet Current for MAIN, Imag = 199.9862 A Vtrans = 1.999818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:47:16 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011204904 Vs 12:47:25 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011214873 Vs 12:47:26 Magnet Current for MAIN, Imag = 199.9866 A Vtrans = 1.999822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:47:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011206570 Vs 12:47:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011212262 Vs 12:47:46 Magnet Current for MAIN, Imag = 199.9861 A Vtrans = 1.999817 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:47:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011204211 Vs 12:48:04 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011213621 Vs 12:48:05 Magnet Current for MAIN, Imag = 199.9854 A Vtrans = 1.999811 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:48:15 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011204771 Vs 12:48:24 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011213481 Vs 12:48:24 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011209337 +- 0.000000365 Vs 12:48:24 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.011209337 +- 0.000000365 Vs BL = 0.11209337 +- 0.00000365 Tm 12:48:24 Integrated Voltage Measurement... 12:48:25 Magnet Current for MAIN, Imag = 199.9861 A Vtrans = 1.999817 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:48:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007481970 Vs 12:48:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007488662 Vs 12:48:46 Magnet Current for MAIN, Imag = 199.9862 A Vtrans = 1.999818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:48:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007482011 Vs 12:49:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007489740 Vs 12:49:05 Magnet Current for MAIN, Imag = 199.9873 A Vtrans = 1.999830 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:49:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007482173 Vs 12:49:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007488329 Vs 12:49:25 Magnet Current for MAIN, Imag = 199.9873 A Vtrans = 1.999830 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:49:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007484029 Vs 12:49:43 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007486813 Vs 12:49:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007485466 +- 0.000000244 Vs 12:49:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007485466 +- 0.000000244 Vs BL = 0.07485466 +- 0.00000244 Tm 12:49:43 Integrated Voltage Measurement... 12:49:44 Magnet Current for MAIN, Imag = 199.9867 A Vtrans = 1.999824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:49:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003766396 Vs 12:50:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003770797 Vs 12:50:05 Magnet Current for MAIN, Imag = 199.9881 A Vtrans = 1.999838 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:50:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003766985 Vs 12:50:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003768819 Vs 12:50:24 Magnet Current for MAIN, Imag = 199.9869 A Vtrans = 1.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:50:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003767263 Vs 12:50:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003769728 Vs 12:50:44 Magnet Current for MAIN, Imag = 199.9875 A Vtrans = 1.999831 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:50:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003765448 Vs 12:51:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003771427 Vs 12:51:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003768358 +- 0.000000269 Vs 12:51:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003768358 +- 0.000000269 Vs BL = 0.03768358 +- 0.00000269 Tm 12:51:03 Integrated Voltage Measurement... 12:51:04 Magnet Current for MAIN, Imag = 199.9858 A Vtrans = 1.999815 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:51:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003664961 Vs 12:51:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003658455 Vs 12:51:24 Magnet Current for MAIN, Imag = 199.9869 A Vtrans = 1.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:51:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003664647 Vs 12:51:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003658691 Vs 12:51:44 Magnet Current for MAIN, Imag = 199.9863 A Vtrans = 1.999820 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:51:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003664364 Vs 12:52:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003658747 Vs 12:52:03 Magnet Current for MAIN, Imag = 199.9871 A Vtrans = 1.999827 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:52:12 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003664792 Vs 12:52:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003658360 Vs 12:52:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003661627 +- 0.000000063 Vs 12:52:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003661627 +- 0.000000063 Vs BL = -0.03661627 +- 0.00000063 Tm 12:52:22 Integrated Voltage Measurement... 12:52:23 Magnet Current for MAIN, Imag = 199.9867 A Vtrans = 1.999824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:52:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007381764 Vs 12:52:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007374704 Vs 12:52:43 Magnet Current for MAIN, Imag = 199.9866 A Vtrans = 1.999822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:52:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007381005 Vs 12:53:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007376490 Vs 12:53:03 Magnet Current for MAIN, Imag = 199.9868 A Vtrans = 1.999825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:53:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007379189 Vs 12:53:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007377752 Vs 12:53:22 Magnet Current for MAIN, Imag = 199.9866 A Vtrans = 1.999822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:53:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007379818 Vs 12:53:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007377522 Vs 12:53:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007378530 +- 0.000000199 Vs 12:53:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007378530 +- 0.000000199 Vs BL = -0.07378530 +- 0.00000199 Tm 12:53:41 Integrated Voltage Measurement... 12:53:42 Magnet Current for MAIN, Imag = 199.9871 A Vtrans = 1.999827 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:53:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011099925 Vs 12:54:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011098197 Vs 12:54:02 Magnet Current for MAIN, Imag = 199.9867 A Vtrans = 1.999824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:54:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011100050 Vs 12:54:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011099135 Vs 12:54:22 Magnet Current for MAIN, Imag = 199.9867 A Vtrans = 1.999824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:54:31 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011099149 Vs 12:54:40 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011098954 Vs 12:54:41 Magnet Current for MAIN, Imag = 199.9872 A Vtrans = 1.999829 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:54:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011101125 Vs 12:55:00 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011097386 Vs 12:55:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011099240 +- 0.000000219 Vs 12:55:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.011099240 +- 0.000000219 Vs BL = -0.11099240 +- 0.00000219 Tm 12:55:04 Position moved: 0.000000 m 12:55:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00054 0.00000 1 -3.71728 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.11209 0.00000 0.11206 0.00004 -0.0200000 0.07485 0.00000 0.07489 -0.00003 -0.0100000 0.03768 0.00000 0.03771 -0.00003 0.0100000 -0.03662 0.00000 -0.03663 0.00002 0.0200000 -0.07379 0.00000 -0.07381 0.00002 0.0300000 -0.11099 0.00000 -0.11098 -0.00001 12:55:04 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.11209 0.00000 -0.0200 0.07485 0.00000 -0.0100 0.03768 0.00000 0.0100 -0.03662 0.00000 0.0200 -0.07379 0.00000 0.0300 -0.11099 0.00000 SL = -3.7172753 +- 0.0000518 Tm^2/m^n 12:55:04 Quadrupole Strength Calculation Check Slope = -3.717275 Tm/m, Inter = 0.000540 Tm, Sig_slope = 0.000591 Tm/m, Est_sig = 0.000031 Tm GL = -3.717275 +- 0.000591 T 12:55:04 Magnet Strength Measurement Harmonic Number = 2 SL = -3.7172753 +- 0.0000518 Tm^2/m^n 12:55:07 Position moved: 0.000000 m 12:55:07 Magnet system MAIN current ramping to 220.0000 A... 12:55:30 Magnet Current for MAIN, Imag = 219.9648 A Vtrans = 2.199605 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:55:31 Main (V) Voltage Measurement, V = 7.551601 V 12:55:32 Temperature Measurement, Probe Number = 0, T = 29.410000 C 12:55:36 Temperature Measurement, Probe Number = 1, T = 29.742000 C 12:55:36 Temperature Measurement, Probe Number = 2, T = 29.344000 C 12:55:37 Temperature Measurement, Probe Number = 3, T = 29.886000 C 12:55:38 Temperature Measurement, Probe Number = 4, T = 23.993000 C 12:55:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.361872 V 12:55:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361872 (V, A, ohm, ...), Measured Value = 28.914885 (C, atm, Hz, ...) 12:55:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.402456 V 12:55:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.402456 (V, A, ohm, ...), Measured Value = 29.478553 (C, atm, Hz, ...) 12:55:41 Sensor Voltage Measurement, Sensor Number = 2, V = 2.645089 V 12:55:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645089 (V, A, ohm, ...), Measured Value = 123.381682 (C, atm, Hz, ...) 12:55:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097605 V 12:55:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097605 (V, A, ohm, ...), Measured Value = 7.320383 (C, atm, Hz, ...) 12:55:45 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003243 V 12:55:45 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003243 (V, A, ohm, ...), Measured Value = 3.242640 (C, atm, Hz, ...) 12:55:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 219.96 P1 = Main (V), Value = 7.55 P2 = Top Right Coil, Value = 29.41 P3 = Bottom Right Coil, Value = 29.74 P4 = Top Left Coil, Value = 29.34 P5 = Bottom Left Coil, Value = 29.89 P6 = Ambient, Value = 23.99 P7 = Supply Temp(C), Value = 28.91 P8 = Return Temp(C), Value = 29.48 P9 = Supply Pres(psi), Value = 123.38 P10 = Return Pres(psi), Value = 7.32 P11 = Flow Rate(gpm), Value = 3.24 12:55:45 Magnetic Field Measurement Measuring the magnet strength... 12:55:45 Integrated Voltage Measurement... 12:55:46 Magnet Current for MAIN, Imag = 219.9649 A Vtrans = 2.199606 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:55:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012327363 Vs 12:56:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012332167 Vs 12:56:07 Magnet Current for MAIN, Imag = 219.9647 A Vtrans = 2.199603 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:56:16 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012325755 Vs 12:56:25 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012333734 Vs 12:56:26 Magnet Current for MAIN, Imag = 219.9645 A Vtrans = 2.199602 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:56:35 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012324319 Vs 12:56:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012334300 Vs 12:56:46 Magnet Current for MAIN, Imag = 219.9652 A Vtrans = 2.199609 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:56:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012325679 Vs 12:57:04 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012332071 Vs 12:57:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012329424 +- 0.000000365 Vs 12:57:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.012329424 +- 0.000000365 Vs BL = 0.12329424 +- 0.00000365 Tm 12:57:04 Integrated Voltage Measurement... 12:57:05 Magnet Current for MAIN, Imag = 219.9631 A Vtrans = 2.199588 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:57:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008229517 Vs 12:57:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008236347 Vs 12:57:26 Magnet Current for MAIN, Imag = 219.9637 A Vtrans = 2.199593 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:57:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008230415 Vs 12:57:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008236630 Vs 12:57:45 Magnet Current for MAIN, Imag = 219.9639 A Vtrans = 2.199596 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:57:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008229343 Vs 12:58:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008236615 Vs 12:58:05 Magnet Current for MAIN, Imag = 219.9638 A Vtrans = 2.199594 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:58:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008230388 Vs 12:58:23 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008236835 Vs 12:58:23 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008233261 +- 0.000000308 Vs 12:58:23 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.008233261 +- 0.000000308 Vs BL = 0.08233261 +- 0.00000308 Tm 12:58:23 Integrated Voltage Measurement... 12:58:24 Magnet Current for MAIN, Imag = 219.9649 A Vtrans = 2.199606 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:58:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004141715 Vs 12:58:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004147113 Vs 12:58:45 Magnet Current for MAIN, Imag = 219.9638 A Vtrans = 2.199594 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:58:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004142919 Vs 12:59:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004147841 Vs 12:59:05 Magnet Current for MAIN, Imag = 219.9648 A Vtrans = 2.199605 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:59:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004142164 Vs 12:59:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004147233 Vs 12:59:24 Magnet Current for MAIN, Imag = 219.9661 A Vtrans = 2.199617 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:59:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004142906 Vs 12:59:42 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004147341 Vs 12:59:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004144904 +- 0.000000373 Vs 12:59:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004144904 +- 0.000000373 Vs BL = 0.04144904 +- 0.00000373 Tm 12:59:43 Integrated Voltage Measurement... 12:59:44 Magnet Current for MAIN, Imag = 219.9649 A Vtrans = 2.199606 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 12:59:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004029883 Vs 13:00:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004024421 Vs 13:00:04 Magnet Current for MAIN, Imag = 219.9650 A Vtrans = 2.199607 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:00:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004030310 Vs 13:00:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004023977 Vs 13:00:24 Magnet Current for MAIN, Imag = 219.9657 A Vtrans = 2.199614 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:00:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004029217 Vs 13:00:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004024362 Vs 13:00:43 Magnet Current for MAIN, Imag = 219.9647 A Vtrans = 2.199603 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:00:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004030355 Vs 13:01:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004023567 Vs 13:01:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004027011 +- 0.000000149 Vs 13:01:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004027011 +- 0.000000149 Vs BL = -0.04027011 +- 0.00000149 Tm 13:01:02 Integrated Voltage Measurement... 13:01:03 Magnet Current for MAIN, Imag = 219.9629 A Vtrans = 2.199586 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:01:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008118170 Vs 13:01:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008111373 Vs 13:01:24 Magnet Current for MAIN, Imag = 219.9640 A Vtrans = 2.199597 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:01:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008119011 Vs 13:01:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008110568 Vs 13:01:43 Magnet Current for MAIN, Imag = 219.9650 A Vtrans = 2.199607 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:01:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008120085 Vs 13:02:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008109020 Vs 13:02:03 Magnet Current for MAIN, Imag = 219.9658 A Vtrans = 2.199615 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:02:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008120224 Vs 13:02:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008110570 Vs 13:02:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008114878 +- 0.000000314 Vs 13:02:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008114878 +- 0.000000314 Vs BL = -0.08114878 +- 0.00000314 Tm 13:02:21 Integrated Voltage Measurement... 13:02:22 Magnet Current for MAIN, Imag = 219.9644 A Vtrans = 2.199601 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:02:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012213148 Vs 13:02:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012202383 Vs 13:02:43 Magnet Current for MAIN, Imag = 219.9659 A Vtrans = 2.199616 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:02:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012212550 Vs 13:03:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012203355 Vs 13:03:03 Magnet Current for MAIN, Imag = 219.9657 A Vtrans = 2.199614 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:03:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012210781 Vs 13:03:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012204325 Vs 13:03:22 Magnet Current for MAIN, Imag = 219.9648 A Vtrans = 2.199605 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:03:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012209543 Vs 13:03:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012204987 Vs 13:03:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012207634 +- 0.000000256 Vs 13:03:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.012207634 +- 0.000000256 Vs BL = -0.12207634 +- 0.00000256 Tm 13:03:45 Position moved: 0.000000 m 13:03:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00060 0.00000 1 -4.08855 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.12329 0.00000 0.12325 0.00004 -0.0200000 0.08233 0.00000 0.08237 -0.00004 -0.0100000 0.04145 0.00000 0.04148 -0.00003 0.0100000 -0.04027 0.00000 -0.04029 0.00002 0.0200000 -0.08115 0.00000 -0.08117 0.00003 0.0300000 -0.12208 0.00000 -0.12206 -0.00002 13:03:45 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.12329 0.00000 -0.0200 0.08233 0.00000 -0.0100 0.04145 0.00000 0.0100 -0.04027 0.00000 0.0200 -0.08115 0.00000 0.0300 -0.12208 0.00000 SL = -4.0885488 +- 0.0000589 Tm^2/m^n 13:03:45 Quadrupole Strength Calculation Check Slope = -4.088549 Tm/m, Inter = 0.000597 Tm, Sig_slope = 0.000687 Tm/m, Est_sig = 0.000036 Tm GL = -4.088549 +- 0.000687 T 13:03:45 Magnet Strength Measurement Harmonic Number = 2 SL = -4.0885488 +- 0.0000589 Tm^2/m^n 13:03:48 Position moved: 0.000000 m 13:03:48 Magnet system MAIN current ramping to 240.0000 A... 13:04:12 Magnet Current for MAIN, Imag = 240.0514 A Vtrans = 2.400470 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:04:13 Main (V) Voltage Measurement, V = 8.247136 V 13:04:14 Temperature Measurement, Probe Number = 0, T = 29.622000 C 13:04:17 Temperature Measurement, Probe Number = 1, T = 29.979000 C 13:04:18 Temperature Measurement, Probe Number = 2, T = 29.532000 C 13:04:19 Temperature Measurement, Probe Number = 3, T = 30.126000 C 13:04:20 Temperature Measurement, Probe Number = 4, T = 24.143000 C 13:04:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.361100 V 13:04:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361100 (V, A, ohm, ...), Measured Value = 28.904169 (C, atm, Hz, ...) 13:04:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.423440 V 13:04:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.423440 (V, A, ohm, ...), Measured Value = 29.770003 (C, atm, Hz, ...) 13:04:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.641869 V 13:04:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.641869 (V, A, ohm, ...), Measured Value = 123.140212 (C, atm, Hz, ...) 13:04:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097824 V 13:04:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097824 (V, A, ohm, ...), Measured Value = 7.336777 (C, atm, Hz, ...) 13:04:27 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003222 V 13:04:27 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003222 (V, A, ohm, ...), Measured Value = 3.222104 (C, atm, Hz, ...) 13:04:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 240.05 P1 = Main (V), Value = 8.25 P2 = Top Right Coil, Value = 29.62 P3 = Bottom Right Coil, Value = 29.98 P4 = Top Left Coil, Value = 29.53 P5 = Bottom Left Coil, Value = 30.13 P6 = Ambient, Value = 24.14 P7 = Supply Temp(C), Value = 28.90 P8 = Return Temp(C), Value = 29.77 P9 = Supply Pres(psi), Value = 123.14 P10 = Return Pres(psi), Value = 7.34 P11 = Flow Rate(gpm), Value = 3.22 13:04:27 Magnetic Field Measurement Measuring the magnet strength... 13:04:27 Integrated Voltage Measurement... 13:04:28 Magnet Current for MAIN, Imag = 240.0374 A Vtrans = 2.400331 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:04:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013452145 Vs 13:04:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013459207 Vs 13:04:48 Magnet Current for MAIN, Imag = 240.0362 A Vtrans = 2.400319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:04:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013449833 Vs 13:05:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013458772 Vs 13:05:08 Magnet Current for MAIN, Imag = 240.0381 A Vtrans = 2.400338 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:05:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013450513 Vs 13:05:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013459065 Vs 13:05:27 Magnet Current for MAIN, Imag = 240.0384 A Vtrans = 2.400341 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:05:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013450858 Vs 13:05:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013458864 Vs 13:05:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013454907 +- 0.000000493 Vs 13:05:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.013454907 +- 0.000000493 Vs BL = 0.13454907 +- 0.00000493 Tm 13:05:46 Integrated Voltage Measurement... 13:05:47 Magnet Current for MAIN, Imag = 240.0373 A Vtrans = 2.400329 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:05:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008979268 Vs 13:06:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008989514 Vs 13:06:08 Magnet Current for MAIN, Imag = 240.0379 A Vtrans = 2.400336 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:06:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008981262 Vs 13:06:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008989506 Vs 13:06:27 Magnet Current for MAIN, Imag = 240.0358 A Vtrans = 2.400315 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:06:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008980869 Vs 13:06:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008987589 Vs 13:06:47 Magnet Current for MAIN, Imag = 240.0390 A Vtrans = 2.400347 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:06:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008982011 Vs 13:07:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008988116 Vs 13:07:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008984767 +- 0.000000474 Vs 13:07:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.008984767 +- 0.000000474 Vs BL = 0.08984767 +- 0.00000474 Tm 13:07:05 Integrated Voltage Measurement... 13:07:06 Magnet Current for MAIN, Imag = 240.0383 A Vtrans = 2.400339 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:07:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004520059 Vs 13:07:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004527311 Vs 13:07:27 Magnet Current for MAIN, Imag = 240.0392 A Vtrans = 2.400348 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:07:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004519012 Vs 13:07:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004527831 Vs 13:07:46 Magnet Current for MAIN, Imag = 240.0380 A Vtrans = 2.400337 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:07:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004517912 Vs 13:08:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004526476 Vs 13:08:06 Magnet Current for MAIN, Imag = 240.0385 A Vtrans = 2.400342 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:08:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004521090 Vs 13:08:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004525663 Vs 13:08:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004523169 +- 0.000000575 Vs 13:08:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004523169 +- 0.000000575 Vs BL = 0.04523169 +- 0.00000575 Tm 13:08:25 Integrated Voltage Measurement... 13:08:26 Magnet Current for MAIN, Imag = 240.0376 A Vtrans = 2.400333 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:08:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004397478 Vs 13:08:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004390603 Vs 13:08:46 Magnet Current for MAIN, Imag = 240.0381 A Vtrans = 2.400338 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:08:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004397832 Vs 13:09:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004390272 Vs 13:09:06 Magnet Current for MAIN, Imag = 240.0415 A Vtrans = 2.400371 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:09:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004398170 Vs 13:09:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004390796 Vs 13:09:25 Magnet Current for MAIN, Imag = 240.0388 A Vtrans = 2.400345 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:09:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004397392 Vs 13:09:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004391157 Vs 13:09:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004394213 +- 0.000000182 Vs 13:09:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004394213 +- 0.000000182 Vs BL = -0.04394213 +- 0.00000182 Tm 13:09:44 Integrated Voltage Measurement... 13:09:45 Magnet Current for MAIN, Imag = 240.0384 A Vtrans = 2.400341 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:09:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008857581 Vs 13:10:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008853872 Vs 13:10:05 Magnet Current for MAIN, Imag = 240.0386 A Vtrans = 2.400343 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:10:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008857569 Vs 13:10:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008852835 Vs 13:10:25 Magnet Current for MAIN, Imag = 240.0380 A Vtrans = 2.400337 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:10:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008857855 Vs 13:10:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008852668 Vs 13:10:45 Magnet Current for MAIN, Imag = 240.0407 A Vtrans = 2.400364 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:10:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008857963 Vs 13:11:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008853306 Vs 13:11:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008855456 +- 0.000000228 Vs 13:11:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008855456 +- 0.000000228 Vs BL = -0.08855456 +- 0.00000228 Tm 13:11:03 Integrated Voltage Measurement... 13:11:04 Magnet Current for MAIN, Imag = 240.0404 A Vtrans = 2.400361 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:11:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013322271 Vs 13:11:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013318567 Vs 13:11:25 Magnet Current for MAIN, Imag = 240.0384 A Vtrans = 2.400341 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:11:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013323968 Vs 13:11:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013318776 Vs 13:11:45 Magnet Current for MAIN, Imag = 240.0394 A Vtrans = 2.400351 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:11:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013324185 Vs 13:12:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013318139 Vs 13:12:04 Magnet Current for MAIN, Imag = 240.0390 A Vtrans = 2.400347 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:12:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013324034 Vs 13:12:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013318098 Vs 13:12:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013321005 +- 0.000000356 Vs 13:12:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.013321005 +- 0.000000356 Vs BL = -0.13321005 +- 0.00000356 Tm 13:12:27 Position moved: 0.000000 m 13:12:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00065 0.00000 1 -4.46163 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.13455 0.00000 0.13450 0.00005 -0.0200000 0.08985 0.00000 0.08989 -0.00004 -0.0100000 0.04523 0.00001 0.04527 -0.00004 0.0100000 -0.04394 0.00000 -0.04396 0.00002 0.0200000 -0.08855 0.00000 -0.08858 0.00002 0.0300000 -0.13321 0.00000 -0.13320 -0.00001 13:12:27 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.13455 0.00000 -0.0200 0.08985 0.00000 -0.0100 0.04523 0.00001 0.0100 -0.04394 0.00000 0.0200 -0.08855 0.00000 0.0300 -0.13321 0.00000 SL = -4.4616273 +- 0.0000782 Tm^2/m^n 13:12:27 Quadrupole Strength Calculation Check Slope = -4.461627 Tm/m, Inter = 0.000654 Tm, Sig_slope = 0.000753 Tm/m, Est_sig = 0.000040 Tm GL = -4.461627 +- 0.000753 T 13:12:27 Magnet Strength Measurement Harmonic Number = 2 SL = -4.4616273 +- 0.0000782 Tm^2/m^n 13:12:29 Position moved: 0.000000 m 13:12:29 Magnet system MAIN current ramping to 260.0000 A... 13:12:53 Magnet Current for MAIN, Imag = 259.9872 A Vtrans = 2.599829 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:12:54 Main (V) Voltage Measurement, V = 8.940161 V 13:12:54 Temperature Measurement, Probe Number = 0, T = 29.907000 C 13:12:58 Temperature Measurement, Probe Number = 1, T = 30.230000 C 13:12:59 Temperature Measurement, Probe Number = 2, T = 29.690000 C 13:13:00 Temperature Measurement, Probe Number = 3, T = 30.405000 C 13:13:01 Temperature Measurement, Probe Number = 4, T = 24.279000 C 13:13:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.360293 V 13:13:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.360293 (V, A, ohm, ...), Measured Value = 28.892958 (C, atm, Hz, ...) 13:13:03 Sensor Voltage Measurement, Sensor Number = 1, V = 2.445898 V 13:13:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.445898 (V, A, ohm, ...), Measured Value = 30.081910 (C, atm, Hz, ...) 13:13:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.675226 V 13:13:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.675226 (V, A, ohm, ...), Measured Value = 125.641972 (C, atm, Hz, ...) 13:13:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097807 V 13:13:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097807 (V, A, ohm, ...), Measured Value = 7.335540 (C, atm, Hz, ...) 13:13:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003248 V 13:13:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003248 (V, A, ohm, ...), Measured Value = 3.248251 (C, atm, Hz, ...) 13:13:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 259.99 P1 = Main (V), Value = 8.94 P2 = Top Right Coil, Value = 29.91 P3 = Bottom Right Coil, Value = 30.23 P4 = Top Left Coil, Value = 29.69 P5 = Bottom Left Coil, Value = 30.41 P6 = Ambient, Value = 24.28 P7 = Supply Temp(C), Value = 28.89 P8 = Return Temp(C), Value = 30.08 P9 = Supply Pres(psi), Value = 125.64 P10 = Return Pres(psi), Value = 7.34 P11 = Flow Rate(gpm), Value = 3.25 13:13:07 Magnetic Field Measurement Measuring the magnet strength... 13:13:07 Integrated Voltage Measurement... 13:13:09 Magnet Current for MAIN, Imag = 259.9890 A Vtrans = 2.599846 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:13:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014573466 Vs 13:13:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014576191 Vs 13:13:29 Magnet Current for MAIN, Imag = 259.9899 A Vtrans = 2.599855 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:13:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014568795 Vs 13:13:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014577478 Vs 13:13:49 Magnet Current for MAIN, Imag = 259.9882 A Vtrans = 2.599839 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:13:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014567496 Vs 13:14:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014574955 Vs 13:14:08 Magnet Current for MAIN, Imag = 259.9896 A Vtrans = 2.599853 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:14:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014573524 Vs 13:14:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014576927 Vs 13:14:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014573604 +- 0.000001581 Vs 13:14:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.014573604 +- 0.000001581 Vs BL = 0.14573604 +- 0.00001581 Tm 13:14:27 Integrated Voltage Measurement... 13:14:28 Magnet Current for MAIN, Imag = 259.9897 A Vtrans = 2.599854 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:14:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009730910 Vs 13:14:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009731499 Vs 13:14:49 Magnet Current for MAIN, Imag = 259.9893 A Vtrans = 2.599850 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:14:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009731652 Vs 13:15:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009734347 Vs 13:15:08 Magnet Current for MAIN, Imag = 259.9890 A Vtrans = 2.599846 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:15:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009730298 Vs 13:15:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009735255 Vs 13:15:28 Magnet Current for MAIN, Imag = 259.9895 A Vtrans = 2.599852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:15:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009727044 Vs 13:15:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009736297 Vs 13:15:47 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009732163 +- 0.000000748 Vs 13:15:47 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.009732163 +- 0.000000748 Vs BL = 0.09732163 +- 0.00000748 Tm 13:15:47 Integrated Voltage Measurement... 13:15:48 Magnet Current for MAIN, Imag = 259.9900 A Vtrans = 2.599857 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:15:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004895414 Vs 13:16:07 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004904306 Vs 13:16:08 Magnet Current for MAIN, Imag = 259.9888 A Vtrans = 2.599845 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:16:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004895495 Vs 13:16:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004904391 Vs 13:16:28 Magnet Current for MAIN, Imag = 259.9858 A Vtrans = 2.599815 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:16:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004896484 Vs 13:16:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004905277 Vs 13:16:47 Magnet Current for MAIN, Imag = 259.9895 A Vtrans = 2.599852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:16:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004894943 Vs 13:17:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004903561 Vs 13:17:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004899984 +- 0.000000582 Vs 13:17:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004899984 +- 0.000000582 Vs BL = 0.04899984 +- 0.00000582 Tm 13:17:06 Integrated Voltage Measurement... 13:17:07 Magnet Current for MAIN, Imag = 259.9883 A Vtrans = 2.599840 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:17:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004765177 Vs 13:17:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004755671 Vs 13:17:27 Magnet Current for MAIN, Imag = 259.9877 A Vtrans = 2.599834 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:17:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004764232 Vs 13:17:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004754588 Vs 13:17:47 Magnet Current for MAIN, Imag = 259.9901 A Vtrans = 2.599858 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:17:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004764717 Vs 13:18:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004753655 Vs 13:18:06 Magnet Current for MAIN, Imag = 259.9890 A Vtrans = 2.599846 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:18:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004764828 Vs 13:18:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004753424 Vs 13:18:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004759536 +- 0.000000523 Vs 13:18:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004759536 +- 0.000000523 Vs BL = -0.04759536 +- 0.00000523 Tm 13:18:25 Integrated Voltage Measurement... 13:18:26 Magnet Current for MAIN, Imag = 259.9905 A Vtrans = 2.599862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:18:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009595553 Vs 13:18:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009585691 Vs 13:18:46 Magnet Current for MAIN, Imag = 259.9905 A Vtrans = 2.599862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:18:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009595056 Vs 13:19:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009586311 Vs 13:19:06 Magnet Current for MAIN, Imag = 259.9892 A Vtrans = 2.599849 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:19:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009596923 Vs 13:19:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009585803 Vs 13:19:25 Magnet Current for MAIN, Imag = 259.9946 A Vtrans = 2.599902 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:19:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009597656 Vs 13:19:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009585461 Vs 13:19:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009591057 +- 0.000000410 Vs 13:19:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.009591057 +- 0.000000410 Vs BL = -0.09591057 +- 0.00000410 Tm 13:19:44 Integrated Voltage Measurement... 13:19:45 Magnet Current for MAIN, Imag = 259.9911 A Vtrans = 2.599868 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:19:55 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014431681 Vs 13:20:04 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014424826 Vs 13:20:05 Magnet Current for MAIN, Imag = 259.9909 A Vtrans = 2.599865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:20:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014431253 Vs 13:20:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014426650 Vs 13:20:25 Magnet Current for MAIN, Imag = 259.9905 A Vtrans = 2.599862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:20:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014430721 Vs 13:20:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014427310 Vs 13:20:45 Magnet Current for MAIN, Imag = 259.9914 A Vtrans = 2.599871 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:20:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014429609 Vs 13:21:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014425192 Vs 13:21:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014428405 +- 0.000000653 Vs 13:21:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.014428405 +- 0.000000653 Vs BL = -0.14428405 +- 0.00000653 Tm 13:21:07 Position moved: 0.000000 m 13:21:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00071 0.00000 1 -4.83257 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.14574 0.00002 0.14569 0.00005 -0.0200000 0.09732 0.00001 0.09736 -0.00004 -0.0100000 0.04900 0.00001 0.04904 -0.00004 0.0100000 -0.04760 0.00001 -0.04761 0.00002 0.0200000 -0.09591 0.00000 -0.09594 0.00003 0.0300000 -0.14428 0.00001 -0.14427 -0.00002 13:21:07 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.14574 0.00002 -0.0200 0.09732 0.00001 -0.0100 0.04900 0.00001 0.0100 -0.04760 0.00001 0.0200 -0.09591 0.00000 0.0300 -0.14428 0.00001 SL = -4.8325710 +- 0.0001952 Tm^2/m^n 13:21:07 Quadrupole Strength Calculation Check Slope = -4.832571 Tm/m, Inter = 0.000711 Tm, Sig_slope = 0.000785 Tm/m, Est_sig = 0.000042 Tm GL = -4.832571 +- 0.000785 T 13:21:07 Magnet Strength Measurement Harmonic Number = 2 SL = -4.8325710 +- 0.0001952 Tm^2/m^n 13:21:10 Position moved: 0.000000 m 13:21:10 Magnet system MAIN current ramping to 280.0000 A... 13:21:33 Magnet Current for MAIN, Imag = 279.9723 A Vtrans = 2.799680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:21:34 Main (V) Voltage Measurement, V = 9.636041 V 13:21:35 Temperature Measurement, Probe Number = 0, T = 30.170000 C 13:21:39 Temperature Measurement, Probe Number = 1, T = 30.504000 C 13:21:40 Temperature Measurement, Probe Number = 2, T = 29.889000 C 13:21:40 Temperature Measurement, Probe Number = 3, T = 30.708000 C 13:21:41 Temperature Measurement, Probe Number = 4, T = 24.426000 C 13:21:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.359555 V 13:21:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359555 (V, A, ohm, ...), Measured Value = 28.882703 (C, atm, Hz, ...) 13:21:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.469785 V 13:21:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.469785 (V, A, ohm, ...), Measured Value = 30.413678 (C, atm, Hz, ...) 13:21:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664675 V 13:21:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664675 (V, A, ohm, ...), Measured Value = 124.850633 (C, atm, Hz, ...) 13:21:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097925 V 13:21:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097925 (V, A, ohm, ...), Measured Value = 7.344405 (C, atm, Hz, ...) 13:21:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003232 V 13:21:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003232 (V, A, ohm, ...), Measured Value = 3.231640 (C, atm, Hz, ...) 13:21:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 279.97 P1 = Main (V), Value = 9.64 P2 = Top Right Coil, Value = 30.17 P3 = Bottom Right Coil, Value = 30.50 P4 = Top Left Coil, Value = 29.89 P5 = Bottom Left Coil, Value = 30.71 P6 = Ambient, Value = 24.43 P7 = Supply Temp(C), Value = 28.88 P8 = Return Temp(C), Value = 30.41 P9 = Supply Pres(psi), Value = 124.85 P10 = Return Pres(psi), Value = 7.34 P11 = Flow Rate(gpm), Value = 3.23 13:21:48 Magnetic Field Measurement Measuring the magnet strength... 13:21:48 Integrated Voltage Measurement... 13:21:49 Magnet Current for MAIN, Imag = 279.9728 A Vtrans = 2.799685 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:21:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015688232 Vs 13:22:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015700168 Vs 13:22:10 Magnet Current for MAIN, Imag = 279.9727 A Vtrans = 2.799684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:22:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015690692 Vs 13:22:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015696807 Vs 13:22:29 Magnet Current for MAIN, Imag = 279.9736 A Vtrans = 2.799693 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:22:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015691123 Vs 13:22:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015694924 Vs 13:22:49 Magnet Current for MAIN, Imag = 279.9727 A Vtrans = 2.799684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:22:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015689407 Vs 13:23:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015700123 Vs 13:23:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015693935 +- 0.000000637 Vs 13:23:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.015693935 +- 0.000000637 Vs BL = 0.15693935 +- 0.00000637 Tm 13:23:07 Integrated Voltage Measurement... 13:23:08 Magnet Current for MAIN, Imag = 279.9731 A Vtrans = 2.799688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:23:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010478180 Vs 13:23:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010486228 Vs 13:23:29 Magnet Current for MAIN, Imag = 279.9744 A Vtrans = 2.799700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:23:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010479649 Vs 13:23:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010483521 Vs 13:23:49 Magnet Current for MAIN, Imag = 279.9726 A Vtrans = 2.799683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:23:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010475613 Vs 13:24:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010482728 Vs 13:24:08 Magnet Current for MAIN, Imag = 279.9716 A Vtrans = 2.799672 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:24:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010475687 Vs 13:24:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010484393 Vs 13:24:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010480750 +- 0.000001205 Vs 13:24:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010480750 +- 0.000001205 Vs BL = 0.10480750 +- 0.00001205 Tm 13:24:27 Integrated Voltage Measurement... 13:24:28 Magnet Current for MAIN, Imag = 279.9722 A Vtrans = 2.799679 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:24:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005272512 Vs 13:24:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005282833 Vs 13:24:48 Magnet Current for MAIN, Imag = 279.9718 A Vtrans = 2.799675 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:24:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005271099 Vs 13:25:07 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005282302 Vs 13:25:08 Magnet Current for MAIN, Imag = 279.9723 A Vtrans = 2.799680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:25:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005273406 Vs 13:25:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005278990 Vs 13:25:27 Magnet Current for MAIN, Imag = 279.9726 A Vtrans = 2.799683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:25:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005272160 Vs 13:25:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005281638 Vs 13:25:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005276868 +- 0.000000530 Vs 13:25:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005276868 +- 0.000000530 Vs BL = 0.05276868 +- 0.00000530 Tm 13:25:46 Integrated Voltage Measurement... 13:25:47 Magnet Current for MAIN, Imag = 279.9718 A Vtrans = 2.799675 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:25:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005129093 Vs 13:26:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005121390 Vs 13:26:07 Magnet Current for MAIN, Imag = 279.9740 A Vtrans = 2.799697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:26:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005127030 Vs 13:26:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005122148 Vs 13:26:27 Magnet Current for MAIN, Imag = 279.9745 A Vtrans = 2.799702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:26:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005128428 Vs 13:26:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005122061 Vs 13:26:47 Magnet Current for MAIN, Imag = 279.9723 A Vtrans = 2.799680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:26:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005127974 Vs 13:27:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005122182 Vs 13:27:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005125038 +- 0.000000268 Vs 13:27:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005125038 +- 0.000000268 Vs BL = -0.05125038 +- 0.00000268 Tm 13:27:05 Integrated Voltage Measurement... 13:27:06 Magnet Current for MAIN, Imag = 279.9726 A Vtrans = 2.799683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:27:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010331508 Vs 13:27:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010325292 Vs 13:27:27 Magnet Current for MAIN, Imag = 279.9741 A Vtrans = 2.799698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:27:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010331824 Vs 13:27:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010324359 Vs 13:27:46 Magnet Current for MAIN, Imag = 279.9731 A Vtrans = 2.799688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:27:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010330901 Vs 13:28:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010324852 Vs 13:28:06 Magnet Current for MAIN, Imag = 279.9724 A Vtrans = 2.799681 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:28:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010331522 Vs 13:28:25 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010324280 Vs 13:28:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010328067 +- 0.000000209 Vs 13:28:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.010328067 +- 0.000000209 Vs BL = -0.10328067 +- 0.00000209 Tm 13:28:25 Integrated Voltage Measurement... 13:28:26 Magnet Current for MAIN, Imag = 279.9758 A Vtrans = 2.799714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:28:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015539973 Vs 13:28:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015535229 Vs 13:28:46 Magnet Current for MAIN, Imag = 279.9716 A Vtrans = 2.799672 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:28:56 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015540124 Vs 13:29:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015535354 Vs 13:29:06 Magnet Current for MAIN, Imag = 279.9732 A Vtrans = 2.799689 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:29:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015538497 Vs 13:29:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015535983 Vs 13:29:25 Magnet Current for MAIN, Imag = 279.9721 A Vtrans = 2.799678 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:29:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015538523 Vs 13:29:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015534321 Vs 13:29:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015537250 +- 0.000000512 Vs 13:29:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.015537250 +- 0.000000512 Vs BL = -0.15537250 +- 0.00000512 Tm 13:29:48 Position moved: 0.000000 m 13:29:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00077 0.00000 1 -5.20404 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.15694 0.00001 0.15689 0.00005 -0.0200000 0.10481 0.00001 0.10485 -0.00004 -0.0100000 0.05277 0.00001 0.05281 -0.00004 0.0100000 -0.05125 0.00000 -0.05127 0.00002 0.0200000 -0.10328 0.00000 -0.10331 0.00003 0.0300000 -0.15537 0.00001 -0.15535 -0.00002 13:29:48 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.15694 0.00001 -0.0200 0.10481 0.00001 -0.0100 0.05277 0.00001 0.0100 -0.05125 0.00000 0.0200 -0.10328 0.00000 0.0300 -0.15537 0.00001 SL = -5.2040391 +- 0.0001255 Tm^2/m^n 13:29:48 Quadrupole Strength Calculation Check Slope = -5.204039 Tm/m, Inter = 0.000769 Tm, Sig_slope = 0.000828 Tm/m, Est_sig = 0.000044 Tm GL = -5.204039 +- 0.000828 T 13:29:48 Magnet Strength Measurement Harmonic Number = 2 SL = -5.2040391 +- 0.0001255 Tm^2/m^n 13:29:50 Position moved: 0.000000 m 13:29:50 Magnet system MAIN current ramping to 300.0000 A... 13:30:14 Magnet Current for MAIN, Imag = 300.0234 A Vtrans = 3.000191 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:30:15 Main (V) Voltage Measurement, V = 10.336647 V 13:30:16 Temperature Measurement, Probe Number = 0, T = 30.454000 C 13:30:19 Temperature Measurement, Probe Number = 1, T = 30.716000 C 13:30:20 Temperature Measurement, Probe Number = 2, T = 30.041000 C 13:30:21 Temperature Measurement, Probe Number = 3, T = 31.043000 C 13:30:22 Temperature Measurement, Probe Number = 4, T = 24.470000 C 13:30:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.359176 V 13:30:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359176 (V, A, ohm, ...), Measured Value = 28.877442 (C, atm, Hz, ...) 13:30:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.495787 V 13:30:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.495787 (V, A, ohm, ...), Measured Value = 30.774821 (C, atm, Hz, ...) 13:30:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664005 V 13:30:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664005 (V, A, ohm, ...), Measured Value = 124.800390 (C, atm, Hz, ...) 13:30:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098276 V 13:30:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098276 (V, A, ohm, ...), Measured Value = 7.370715 (C, atm, Hz, ...) 13:30:29 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003268 V 13:30:29 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003268 (V, A, ohm, ...), Measured Value = 3.268236 (C, atm, Hz, ...) 13:30:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.02 P1 = Main (V), Value = 10.34 P2 = Top Right Coil, Value = 30.45 P3 = Bottom Right Coil, Value = 30.72 P4 = Top Left Coil, Value = 30.04 P5 = Bottom Left Coil, Value = 31.04 P6 = Ambient, Value = 24.47 P7 = Supply Temp(C), Value = 28.88 P8 = Return Temp(C), Value = 30.77 P9 = Supply Pres(psi), Value = 124.80 P10 = Return Pres(psi), Value = 7.37 P11 = Flow Rate(gpm), Value = 3.27 13:30:29 Magnetic Field Measurement Measuring the magnet strength... 13:30:29 Integrated Voltage Measurement... 13:30:30 Magnet Current for MAIN, Imag = 300.0247 A Vtrans = 3.000204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:30:40 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.016816531 Vs 13:30:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.016818462 Vs 13:30:50 Magnet Current for MAIN, Imag = 300.0234 A Vtrans = 3.000191 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:30:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.016816686 Vs 13:31:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.016819871 Vs 13:31:10 Magnet Current for MAIN, Imag = 300.0245 A Vtrans = 3.000201 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:31:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.016814855 Vs 13:31:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.016823678 Vs 13:31:29 Magnet Current for MAIN, Imag = 300.0265 A Vtrans = 3.000222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:31:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.016814133 Vs 13:31:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.016819738 Vs 13:31:47 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.016817994 +- 0.000000876 Vs 13:31:47 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.016817994 +- 0.000000876 Vs BL = 0.16817994 +- 0.00000876 Tm 13:31:47 Integrated Voltage Measurement... 13:31:48 Magnet Current for MAIN, Imag = 300.0275 A Vtrans = 3.000232 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:31:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011231394 Vs 13:32:08 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011234980 Vs 13:32:09 Magnet Current for MAIN, Imag = 300.0237 A Vtrans = 3.000194 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:32:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011229414 Vs 13:32:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011233361 Vs 13:32:28 Magnet Current for MAIN, Imag = 300.0232 A Vtrans = 3.000189 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:32:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011232075 Vs 13:32:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011235469 Vs 13:32:48 Magnet Current for MAIN, Imag = 300.0246 A Vtrans = 3.000202 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:32:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011229501 Vs 13:33:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011233707 Vs 13:33:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011232487 +- 0.000001016 Vs 13:33:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.011232487 +- 0.000001016 Vs BL = 0.11232487 +- 0.00001016 Tm 13:33:06 Integrated Voltage Measurement... 13:33:07 Magnet Current for MAIN, Imag = 300.0223 A Vtrans = 3.000180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:33:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005653625 Vs 13:33:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005657832 Vs 13:33:28 Magnet Current for MAIN, Imag = 300.0248 A Vtrans = 3.000205 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:33:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005654847 Vs 13:33:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005655670 Vs 13:33:47 Magnet Current for MAIN, Imag = 300.0252 A Vtrans = 3.000209 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:33:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005655890 Vs 13:34:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005656063 Vs 13:34:06 Magnet Current for MAIN, Imag = 300.0242 A Vtrans = 3.000199 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:34:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005652882 Vs 13:34:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005657863 Vs 13:34:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005655584 +- 0.000000285 Vs 13:34:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005655584 +- 0.000000285 Vs BL = 0.05655584 +- 0.00000285 Tm 13:34:25 Integrated Voltage Measurement... 13:34:26 Magnet Current for MAIN, Imag = 300.0265 A Vtrans = 3.000222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:34:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005493733 Vs 13:34:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005489840 Vs 13:34:46 Magnet Current for MAIN, Imag = 300.0274 A Vtrans = 3.000230 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:34:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005492897 Vs 13:35:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005489838 Vs 13:35:06 Magnet Current for MAIN, Imag = 300.0233 A Vtrans = 3.000190 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:35:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005494705 Vs 13:35:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005489099 Vs 13:35:25 Magnet Current for MAIN, Imag = 300.0234 A Vtrans = 3.000191 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:35:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005495498 Vs 13:35:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005488834 Vs 13:35:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005491805 +- 0.000000288 Vs 13:35:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005491805 +- 0.000000288 Vs BL = -0.05491805 +- 0.00000288 Tm 13:35:44 Integrated Voltage Measurement... 13:35:45 Magnet Current for MAIN, Imag = 300.0241 A Vtrans = 3.000197 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:35:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.011070499 Vs 13:36:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.011065736 Vs 13:36:05 Magnet Current for MAIN, Imag = 300.0256 A Vtrans = 3.000213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:36:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.011070062 Vs 13:36:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.011066669 Vs 13:36:24 Magnet Current for MAIN, Imag = 300.0245 A Vtrans = 3.000201 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:36:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.011070593 Vs 13:36:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.011066330 Vs 13:36:44 Magnet Current for MAIN, Imag = 300.0242 A Vtrans = 3.000199 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:36:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.011068763 Vs 13:37:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.011065863 Vs 13:37:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.011068064 +- 0.000000452 Vs 13:37:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.011068064 +- 0.000000452 Vs BL = -0.11068064 +- 0.00000452 Tm 13:37:02 Integrated Voltage Measurement... 13:37:03 Magnet Current for MAIN, Imag = 300.0745 A Vtrans = 3.000702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:37:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016652335 Vs 13:37:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016646427 Vs 13:37:24 Magnet Current for MAIN, Imag = 300.0233 A Vtrans = 3.000190 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:37:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016653938 Vs 13:37:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016647001 Vs 13:37:43 Magnet Current for MAIN, Imag = 300.0248 A Vtrans = 3.000205 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:37:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016655547 Vs 13:38:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016646196 Vs 13:38:03 Magnet Current for MAIN, Imag = 300.0239 A Vtrans = 3.000196 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:38:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016656881 Vs 13:38:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016645655 Vs 13:38:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016650498 +- 0.000000704 Vs 13:38:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.016650498 +- 0.000000704 Vs BL = -0.16650498 +- 0.00000704 Tm 13:38:25 Position moved: 0.000000 m 13:38:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00083 0.00000 1 -5.57693 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.16818 0.00001 0.16813 0.00005 -0.0200000 0.11232 0.00001 0.11236 -0.00004 -0.0100000 0.05656 0.00000 0.05660 -0.00004 0.0100000 -0.05492 0.00000 -0.05494 0.00003 0.0200000 -0.11068 0.00000 -0.11071 0.00003 0.0300000 -0.16650 0.00001 -0.16648 -0.00002 13:38:25 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.16818 0.00001 -0.0200 0.11232 0.00001 -0.0100 0.05656 0.00000 0.0100 -0.05492 0.00000 0.0200 -0.11068 0.00000 0.0300 -0.16650 0.00001 SL = -5.5769274 +- 0.0001449 Tm^2/m^n 13:38:25 Quadrupole Strength Calculation Check Slope = -5.576927 Tm/m, Inter = 0.000826 Tm, Sig_slope = 0.000815 Tm/m, Est_sig = 0.000043 Tm GL = -5.576927 +- 0.000815 T 13:38:25 Magnet Strength Measurement Harmonic Number = 2 SL = -5.5769274 +- 0.0001449 Tm^2/m^n 13:38:28 Position moved: 0.000000 m 13:38:28 Magnet system MAIN current ramping to 280.0000 A... 13:38:51 Magnet Current for MAIN, Imag = 279.9764 A Vtrans = 2.799721 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:38:52 Main (V) Voltage Measurement, V = 9.640704 V 13:38:53 Temperature Measurement, Probe Number = 0, T = 30.724000 C 13:38:57 Temperature Measurement, Probe Number = 1, T = 30.933000 C 13:38:57 Temperature Measurement, Probe Number = 2, T = 30.167000 C 13:38:58 Temperature Measurement, Probe Number = 3, T = 31.243000 C 13:38:59 Temperature Measurement, Probe Number = 4, T = 24.477000 C 13:39:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.360287 V 13:39:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.360287 (V, A, ohm, ...), Measured Value = 28.892871 (C, atm, Hz, ...) 13:39:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.524129 V 13:39:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.524129 (V, A, ohm, ...), Measured Value = 31.168453 (C, atm, Hz, ...) 13:39:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.645278 V 13:39:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645278 (V, A, ohm, ...), Measured Value = 123.395887 (C, atm, Hz, ...) 13:39:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098924 V 13:39:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098924 (V, A, ohm, ...), Measured Value = 7.419330 (C, atm, Hz, ...) 13:39:06 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003255 V 13:39:06 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003255 (V, A, ohm, ...), Measured Value = 3.254627 (C, atm, Hz, ...) 13:39:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 279.98 P1 = Main (V), Value = 9.64 P2 = Top Right Coil, Value = 30.72 P3 = Bottom Right Coil, Value = 30.93 P4 = Top Left Coil, Value = 30.17 P5 = Bottom Left Coil, Value = 31.24 P6 = Ambient, Value = 24.48 P7 = Supply Temp(C), Value = 28.89 P8 = Return Temp(C), Value = 31.17 P9 = Supply Pres(psi), Value = 123.40 P10 = Return Pres(psi), Value = 7.42 P11 = Flow Rate(gpm), Value = 3.25 13:39:06 Magnetic Field Measurement Measuring the magnet strength... 13:39:06 Integrated Voltage Measurement... 13:39:07 Magnet Current for MAIN, Imag = 279.9780 A Vtrans = 2.799737 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:39:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015706989 Vs 13:39:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015712219 Vs 13:39:27 Magnet Current for MAIN, Imag = 279.9798 A Vtrans = 2.799755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:39:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015708331 Vs 13:39:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015714892 Vs 13:39:47 Magnet Current for MAIN, Imag = 279.9758 A Vtrans = 2.799714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:39:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015709404 Vs 13:40:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015711770 Vs 13:40:06 Magnet Current for MAIN, Imag = 279.9771 A Vtrans = 2.799728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:40:15 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015711255 Vs 13:40:25 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015714303 Vs 13:40:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015711146 +- 0.000001180 Vs 13:40:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.015711146 +- 0.000001180 Vs BL = 0.15711146 +- 0.00001180 Tm 13:40:25 Integrated Voltage Measurement... 13:40:26 Magnet Current for MAIN, Imag = 279.9764 A Vtrans = 2.799721 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:40:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010492884 Vs 13:40:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010495756 Vs 13:40:47 Magnet Current for MAIN, Imag = 279.9761 A Vtrans = 2.799718 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:40:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010491397 Vs 13:41:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010491881 Vs 13:41:06 Magnet Current for MAIN, Imag = 279.9761 A Vtrans = 2.799718 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:41:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010489882 Vs 13:41:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010491872 Vs 13:41:26 Magnet Current for MAIN, Imag = 279.9789 A Vtrans = 2.799746 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:41:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010491617 Vs 13:41:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010493425 Vs 13:41:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010492339 +- 0.000001283 Vs 13:41:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010492339 +- 0.000001283 Vs BL = 0.10492339 +- 0.00001283 Tm 13:41:44 Integrated Voltage Measurement... 13:41:45 Magnet Current for MAIN, Imag = 279.9755 A Vtrans = 2.799712 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:41:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005283790 Vs 13:42:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005284305 Vs 13:42:06 Magnet Current for MAIN, Imag = 279.9756 A Vtrans = 2.799713 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:42:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005279978 Vs 13:42:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005283003 Vs 13:42:25 Magnet Current for MAIN, Imag = 279.9759 A Vtrans = 2.799716 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:42:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005279292 Vs 13:42:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005282856 Vs 13:42:45 Magnet Current for MAIN, Imag = 279.9759 A Vtrans = 2.799716 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:42:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005280337 Vs 13:43:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005286586 Vs 13:43:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005282519 +- 0.000001262 Vs 13:43:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005282519 +- 0.000001262 Vs BL = 0.05282519 +- 0.00001262 Tm 13:43:03 Integrated Voltage Measurement... 13:43:04 Magnet Current for MAIN, Imag = 279.9779 A Vtrans = 2.799736 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:43:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005133695 Vs 13:43:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005128330 Vs 13:43:25 Magnet Current for MAIN, Imag = 279.9759 A Vtrans = 2.799716 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:43:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005132149 Vs 13:43:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005129292 Vs 13:43:44 Magnet Current for MAIN, Imag = 279.9768 A Vtrans = 2.799724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:43:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005132533 Vs 13:44:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005128454 Vs 13:44:04 Magnet Current for MAIN, Imag = 279.9750 A Vtrans = 2.799707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:44:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005132905 Vs 13:44:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005128285 Vs 13:44:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005130705 +- 0.000000195 Vs 13:44:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005130705 +- 0.000000195 Vs BL = -0.05130705 +- 0.00000195 Tm 13:44:22 Integrated Voltage Measurement... 13:44:24 Magnet Current for MAIN, Imag = 279.9783 A Vtrans = 2.799740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:44:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010341762 Vs 13:44:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010337444 Vs 13:44:44 Magnet Current for MAIN, Imag = 279.9765 A Vtrans = 2.799722 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:44:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010343481 Vs 13:45:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010335955 Vs 13:45:04 Magnet Current for MAIN, Imag = 279.9764 A Vtrans = 2.799721 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:45:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010344278 Vs 13:45:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010335360 Vs 13:45:23 Magnet Current for MAIN, Imag = 279.9768 A Vtrans = 2.799724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:45:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010344775 Vs 13:45:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010334608 Vs 13:45:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010339708 +- 0.000000077 Vs 13:45:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.010339708 +- 0.000000077 Vs BL = -0.10339708 +- 0.00000077 Tm 13:45:42 Integrated Voltage Measurement... 13:45:43 Magnet Current for MAIN, Imag = 279.9771 A Vtrans = 2.799728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:45:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015559106 Vs 13:46:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015549582 Vs 13:46:03 Magnet Current for MAIN, Imag = 279.9754 A Vtrans = 2.799711 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:46:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015557945 Vs 13:46:22 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015551297 Vs 13:46:23 Magnet Current for MAIN, Imag = 279.9765 A Vtrans = 2.799722 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:46:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015556848 Vs 13:46:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015551537 Vs 13:46:42 Magnet Current for MAIN, Imag = 279.9764 A Vtrans = 2.799721 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:46:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015556070 Vs 13:47:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.015551756 Vs 13:47:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.015554268 +- 0.000000256 Vs 13:47:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.015554268 +- 0.000000256 Vs BL = -0.15554268 +- 0.00000256 Tm 13:47:05 Position moved: 0.000000 m 13:47:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00077 0.00000 1 -5.20977 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.15711 0.00001 0.15706 0.00005 -0.0200000 0.10492 0.00001 0.10496 -0.00004 -0.0100000 0.05283 0.00001 0.05287 -0.00004 0.0100000 -0.05131 0.00000 -0.05133 0.00002 0.0200000 -0.10340 0.00000 -0.10343 0.00003 0.0300000 -0.15554 0.00000 -0.15552 -0.00002 13:47:05 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.15711 0.00001 -0.0200 0.10492 0.00001 -0.0100 0.05283 0.00001 0.0100 -0.05131 0.00000 0.0200 -0.10340 0.00000 0.0300 -0.15554 0.00000 SL = -5.2097699 +- 0.0001651 Tm^2/m^n 13:47:05 Quadrupole Strength Calculation Check Slope = -5.209770 Tm/m, Inter = 0.000769 Tm, Sig_slope = 0.000819 Tm/m, Est_sig = 0.000043 Tm GL = -5.209770 +- 0.000819 T 13:47:05 Magnet Strength Measurement Harmonic Number = 2 SL = -5.2097699 +- 0.0001651 Tm^2/m^n 13:47:08 Position moved: 0.000000 m 13:47:08 Magnet system MAIN current ramping to 260.0000 A... 13:47:31 Magnet Current for MAIN, Imag = 259.9948 A Vtrans = 2.599905 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:47:32 Main (V) Voltage Measurement, V = 8.944487 V 13:47:33 Temperature Measurement, Probe Number = 0, T = 30.456000 C 13:47:37 Temperature Measurement, Probe Number = 1, T = 30.691000 C 13:47:38 Temperature Measurement, Probe Number = 2, T = 29.998000 C 13:47:38 Temperature Measurement, Probe Number = 3, T = 30.981000 C 13:47:39 Temperature Measurement, Probe Number = 4, T = 24.670000 C 13:47:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.360465 V 13:47:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.360465 (V, A, ohm, ...), Measured Value = 28.895342 (C, atm, Hz, ...) 13:47:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.523932 V 13:47:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.523932 (V, A, ohm, ...), Measured Value = 31.165717 (C, atm, Hz, ...) 13:47:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.671737 V 13:47:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671737 (V, A, ohm, ...), Measured Value = 125.380290 (C, atm, Hz, ...) 13:47:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098542 V 13:47:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098542 (V, A, ohm, ...), Measured Value = 7.390635 (C, atm, Hz, ...) 13:47:46 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003274 V 13:47:46 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003274 (V, A, ohm, ...), Measured Value = 3.273905 (C, atm, Hz, ...) 13:47:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 259.99 P1 = Main (V), Value = 8.94 P2 = Top Right Coil, Value = 30.46 P3 = Bottom Right Coil, Value = 30.69 P4 = Top Left Coil, Value = 30.00 P5 = Bottom Left Coil, Value = 30.98 P6 = Ambient, Value = 24.67 P7 = Supply Temp(C), Value = 28.90 P8 = Return Temp(C), Value = 31.17 P9 = Supply Pres(psi), Value = 125.38 P10 = Return Pres(psi), Value = 7.39 P11 = Flow Rate(gpm), Value = 3.27 13:47:46 Magnetic Field Measurement Measuring the magnet strength... 13:47:46 Integrated Voltage Measurement... 13:47:47 Magnet Current for MAIN, Imag = 259.9954 A Vtrans = 2.599911 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:47:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014602608 Vs 13:48:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014602746 Vs 13:48:07 Magnet Current for MAIN, Imag = 259.9937 A Vtrans = 2.599893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:48:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014602591 Vs 13:48:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014604267 Vs 13:48:27 Magnet Current for MAIN, Imag = 259.9942 A Vtrans = 2.599899 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:48:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014601046 Vs 13:48:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014604166 Vs 13:48:46 Magnet Current for MAIN, Imag = 259.9947 A Vtrans = 2.599904 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:48:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014601028 Vs 13:49:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.014601642 Vs 13:49:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.014602512 +- 0.000000752 Vs 13:49:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.014602512 +- 0.000000752 Vs BL = 0.14602512 +- 0.00000752 Tm 13:49:05 Integrated Voltage Measurement... 13:49:06 Magnet Current for MAIN, Imag = 259.9951 A Vtrans = 2.599907 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:49:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009749857 Vs 13:49:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009756927 Vs 13:49:27 Magnet Current for MAIN, Imag = 259.9929 A Vtrans = 2.599886 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:49:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009747993 Vs 13:49:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009753156 Vs 13:49:46 Magnet Current for MAIN, Imag = 259.9939 A Vtrans = 2.599896 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:49:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009746166 Vs 13:50:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009756494 Vs 13:50:05 Magnet Current for MAIN, Imag = 259.9940 A Vtrans = 2.599897 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:50:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009748874 Vs 13:50:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009752680 Vs 13:50:24 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009751518 +- 0.000001117 Vs 13:50:24 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.009751518 +- 0.000001117 Vs BL = 0.09751518 +- 0.00001117 Tm 13:50:24 Integrated Voltage Measurement... 13:50:25 Magnet Current for MAIN, Imag = 259.9932 A Vtrans = 2.599888 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:50:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004907499 Vs 13:50:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004913366 Vs 13:50:46 Magnet Current for MAIN, Imag = 259.9951 A Vtrans = 2.599907 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:50:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004906669 Vs 13:51:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004912788 Vs 13:51:05 Magnet Current for MAIN, Imag = 259.9921 A Vtrans = 2.599878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:51:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004906253 Vs 13:51:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004911767 Vs 13:51:25 Magnet Current for MAIN, Imag = 259.9938 A Vtrans = 2.599895 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:51:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004906615 Vs 13:51:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004912082 Vs 13:51:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004909630 +- 0.000000529 Vs 13:51:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004909630 +- 0.000000529 Vs BL = 0.04909630 +- 0.00000529 Tm 13:51:44 Integrated Voltage Measurement... 13:51:45 Magnet Current for MAIN, Imag = 259.9942 A Vtrans = 2.599899 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:51:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004772642 Vs 13:52:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004764441 Vs 13:52:05 Magnet Current for MAIN, Imag = 259.9925 A Vtrans = 2.599882 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:52:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004773448 Vs 13:52:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004763852 Vs 13:52:25 Magnet Current for MAIN, Imag = 259.9947 A Vtrans = 2.599904 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:52:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004773404 Vs 13:52:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004764374 Vs 13:52:44 Magnet Current for MAIN, Imag = 259.9937 A Vtrans = 2.599893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:52:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004773010 Vs 13:53:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004765609 Vs 13:53:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004768848 +- 0.000000295 Vs 13:53:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004768848 +- 0.000000295 Vs BL = -0.04768848 +- 0.00000295 Tm 13:53:03 Integrated Voltage Measurement... 13:53:04 Magnet Current for MAIN, Imag = 259.9954 A Vtrans = 2.599911 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:53:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009612052 Vs 13:53:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009607220 Vs 13:53:24 Magnet Current for MAIN, Imag = 259.9957 A Vtrans = 2.599914 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:53:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009613083 Vs 13:53:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009606192 Vs 13:53:44 Magnet Current for MAIN, Imag = 259.9947 A Vtrans = 2.599904 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:53:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009613417 Vs 13:54:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009606331 Vs 13:54:03 Magnet Current for MAIN, Imag = 259.9932 A Vtrans = 2.599888 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:54:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009613270 Vs 13:54:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009607567 Vs 13:54:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009609892 +- 0.000000319 Vs 13:54:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.009609892 +- 0.000000319 Vs BL = -0.09609892 +- 0.00000319 Tm 13:54:22 Integrated Voltage Measurement... 13:54:23 Magnet Current for MAIN, Imag = 259.9935 A Vtrans = 2.599892 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:54:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014460186 Vs 13:54:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014453278 Vs 13:54:43 Magnet Current for MAIN, Imag = 259.9935 A Vtrans = 2.599892 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:54:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014460763 Vs 13:55:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014453725 Vs 13:55:03 Magnet Current for MAIN, Imag = 259.9952 A Vtrans = 2.599909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:55:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014458800 Vs 13:55:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014454098 Vs 13:55:22 Magnet Current for MAIN, Imag = 259.9953 A Vtrans = 2.599910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:55:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014458704 Vs 13:55:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014453652 Vs 13:55:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014456651 +- 0.000000395 Vs 13:55:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.014456651 +- 0.000000395 Vs BL = -0.14456651 +- 0.00000395 Tm 13:55:45 Position moved: 0.000000 m 13:55:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00071 0.00000 1 -4.84210 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.14603 0.00001 0.14598 0.00005 -0.0200000 0.09752 0.00001 0.09756 -0.00004 -0.0100000 0.04910 0.00001 0.04913 -0.00004 0.0100000 -0.04769 0.00000 -0.04771 0.00002 0.0200000 -0.09610 0.00000 -0.09613 0.00003 0.0300000 -0.14457 0.00000 -0.14455 -0.00002 13:55:45 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.14603 0.00001 -0.0200 0.09752 0.00001 -0.0100 0.04910 0.00001 0.0100 -0.04769 0.00000 0.0200 -0.09610 0.00000 0.0300 -0.14457 0.00000 SL = -4.8420995 +- 0.0001250 Tm^2/m^n 13:55:45 Quadrupole Strength Calculation Check Slope = -4.842099 Tm/m, Inter = 0.000714 Tm, Sig_slope = 0.000789 Tm/m, Est_sig = 0.000042 Tm GL = -4.842099 +- 0.000789 T 13:55:45 Magnet Strength Measurement Harmonic Number = 2 SL = -4.8420995 +- 0.0001250 Tm^2/m^n 13:55:48 Position moved: 0.000000 m 13:55:48 Magnet system MAIN current ramping to 240.0000 A... 13:56:11 Magnet Current for MAIN, Imag = 240.0437 A Vtrans = 2.400394 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:56:12 Main (V) Voltage Measurement, V = 8.251535 V 13:56:13 Temperature Measurement, Probe Number = 0, T = 30.218000 C 13:56:17 Temperature Measurement, Probe Number = 1, T = 30.477000 C 13:56:18 Temperature Measurement, Probe Number = 2, T = 29.871000 C 13:56:18 Temperature Measurement, Probe Number = 3, T = 30.717000 C 13:56:19 Temperature Measurement, Probe Number = 4, T = 24.762000 C 13:56:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.361096 V 13:56:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361096 (V, A, ohm, ...), Measured Value = 28.904117 (C, atm, Hz, ...) 13:56:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.510397 V 13:56:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.510397 (V, A, ohm, ...), Measured Value = 30.977735 (C, atm, Hz, ...) 13:56:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660575 V 13:56:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660575 (V, A, ohm, ...), Measured Value = 124.543095 (C, atm, Hz, ...) 13:56:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098431 V 13:56:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098431 (V, A, ohm, ...), Measured Value = 7.382348 (C, atm, Hz, ...) 13:56:26 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003231 V 13:56:26 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003231 (V, A, ohm, ...), Measured Value = 3.230530 (C, atm, Hz, ...) 13:56:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 240.04 P1 = Main (V), Value = 8.25 P2 = Top Right Coil, Value = 30.22 P3 = Bottom Right Coil, Value = 30.48 P4 = Top Left Coil, Value = 29.87 P5 = Bottom Left Coil, Value = 30.72 P6 = Ambient, Value = 24.76 P7 = Supply Temp(C), Value = 28.90 P8 = Return Temp(C), Value = 30.98 P9 = Supply Pres(psi), Value = 124.54 P10 = Return Pres(psi), Value = 7.38 P11 = Flow Rate(gpm), Value = 3.23 13:56:26 Magnetic Field Measurement Measuring the magnet strength... 13:56:26 Integrated Voltage Measurement... 13:56:27 Magnet Current for MAIN, Imag = 240.0435 A Vtrans = 2.400392 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:56:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013486241 Vs 13:56:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013493444 Vs 13:56:48 Magnet Current for MAIN, Imag = 240.0436 A Vtrans = 2.400393 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:56:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013487123 Vs 13:57:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013493638 Vs 13:57:07 Magnet Current for MAIN, Imag = 240.0441 A Vtrans = 2.400398 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:57:16 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013488292 Vs 13:57:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013493670 Vs 13:57:27 Magnet Current for MAIN, Imag = 240.0425 A Vtrans = 2.400381 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:57:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013489653 Vs 13:57:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013492439 Vs 13:57:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013490562 +- 0.000000490 Vs 13:57:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.013490562 +- 0.000000490 Vs BL = 0.13490562 +- 0.00000490 Tm 13:57:45 Integrated Voltage Measurement... 13:57:46 Magnet Current for MAIN, Imag = 240.0436 A Vtrans = 2.400393 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:57:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009006530 Vs 13:58:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009009638 Vs 13:58:07 Magnet Current for MAIN, Imag = 240.0439 A Vtrans = 2.400395 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:58:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009007779 Vs 13:58:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009011981 Vs 13:58:26 Magnet Current for MAIN, Imag = 240.0425 A Vtrans = 2.400381 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:58:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009006317 Vs 13:58:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009011492 Vs 13:58:46 Magnet Current for MAIN, Imag = 240.0442 A Vtrans = 2.400399 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:58:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009006271 Vs 13:59:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.009012184 Vs 13:59:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.009009024 +- 0.000000647 Vs 13:59:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.009009024 +- 0.000000647 Vs BL = 0.09009024 +- 0.00000647 Tm 13:59:04 Integrated Voltage Measurement... 13:59:05 Magnet Current for MAIN, Imag = 240.0447 A Vtrans = 2.400404 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:59:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004533480 Vs 13:59:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004538831 Vs 13:59:26 Magnet Current for MAIN, Imag = 240.0440 A Vtrans = 2.400397 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:59:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004532386 Vs 13:59:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004538726 Vs 13:59:45 Magnet Current for MAIN, Imag = 240.0432 A Vtrans = 2.400389 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 13:59:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004534374 Vs 14:00:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004536860 Vs 14:00:05 Magnet Current for MAIN, Imag = 240.0439 A Vtrans = 2.400395 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:00:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004534122 Vs 14:00:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004538757 Vs 14:00:23 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004535942 +- 0.000000370 Vs 14:00:23 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004535942 +- 0.000000370 Vs BL = 0.04535942 +- 0.00000370 Tm 14:00:23 Integrated Voltage Measurement... 14:00:24 Magnet Current for MAIN, Imag = 240.0439 A Vtrans = 2.400395 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:00:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004408763 Vs 14:00:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004404344 Vs 14:00:45 Magnet Current for MAIN, Imag = 240.0428 A Vtrans = 2.400385 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:00:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004407433 Vs 14:01:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004405439 Vs 14:01:04 Magnet Current for MAIN, Imag = 240.0440 A Vtrans = 2.400397 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:01:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004406995 Vs 14:01:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004406547 Vs 14:01:24 Magnet Current for MAIN, Imag = 240.0437 A Vtrans = 2.400394 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:01:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004406864 Vs 14:01:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004405756 Vs 14:01:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004406517 +- 0.000000170 Vs 14:01:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004406517 +- 0.000000170 Vs BL = -0.04406517 +- 0.00000170 Tm 14:01:43 Integrated Voltage Measurement... 14:01:44 Magnet Current for MAIN, Imag = 240.0432 A Vtrans = 2.400389 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:01:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008881926 Vs 14:02:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008877040 Vs 14:02:04 Magnet Current for MAIN, Imag = 240.0431 A Vtrans = 2.400388 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:02:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008880299 Vs 14:02:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008877328 Vs 14:02:23 Magnet Current for MAIN, Imag = 240.0437 A Vtrans = 2.400394 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:02:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008881965 Vs 14:02:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008875582 Vs 14:02:43 Magnet Current for MAIN, Imag = 240.0449 A Vtrans = 2.400406 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:02:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008883798 Vs 14:03:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008874561 Vs 14:03:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008879062 +- 0.000000290 Vs 14:03:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008879062 +- 0.000000290 Vs BL = -0.08879062 +- 0.00000290 Tm 14:03:02 Integrated Voltage Measurement... 14:03:03 Magnet Current for MAIN, Imag = 240.0421 A Vtrans = 2.400378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:03:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013359950 Vs 14:03:22 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013354642 Vs 14:03:23 Magnet Current for MAIN, Imag = 240.0440 A Vtrans = 2.400397 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:03:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013359540 Vs 14:03:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013354141 Vs 14:03:43 Magnet Current for MAIN, Imag = 240.0447 A Vtrans = 2.400404 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:03:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013360078 Vs 14:04:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013354319 Vs 14:04:02 Magnet Current for MAIN, Imag = 240.0441 A Vtrans = 2.400398 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:04:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013360164 Vs 14:04:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.013353455 Vs 14:04:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.013357036 +- 0.000000214 Vs 14:04:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.013357036 +- 0.000000214 Vs BL = -0.13357036 +- 0.00000214 Tm 14:04:25 Position moved: 0.000000 m 14:04:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00065 0.00000 1 -4.47362 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.13491 0.00000 0.13486 0.00004 -0.0200000 0.09009 0.00001 0.09013 -0.00004 -0.0100000 0.04536 0.00000 0.04539 -0.00003 0.0100000 -0.04407 0.00000 -0.04408 0.00002 0.0200000 -0.08879 0.00000 -0.08882 0.00003 0.0300000 -0.13357 0.00000 -0.13355 -0.00002 14:04:25 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.13491 0.00000 -0.0200 0.09009 0.00001 -0.0100 0.04536 0.00000 0.0100 -0.04407 0.00000 0.0200 -0.08879 0.00000 0.0300 -0.13357 0.00000 SL = -4.4736225 +- 0.0000778 Tm^2/m^n 14:04:25 Quadrupole Strength Calculation Check Slope = -4.473622 Tm/m, Inter = 0.000655 Tm, Sig_slope = 0.000695 Tm/m, Est_sig = 0.000037 Tm GL = -4.473622 +- 0.000695 T 14:04:25 Magnet Strength Measurement Harmonic Number = 2 SL = -4.4736225 +- 0.0000778 Tm^2/m^n 14:04:28 Position moved: 0.000000 m 14:04:28 Magnet system MAIN current ramping to 220.0000 A... 14:04:51 Magnet Current for MAIN, Imag = 219.9701 A Vtrans = 2.199658 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:04:52 Main (V) Voltage Measurement, V = 7.555344 V 14:04:53 Temperature Measurement, Probe Number = 0, T = 30.001000 C 14:04:57 Temperature Measurement, Probe Number = 1, T = 30.240000 C 14:04:58 Temperature Measurement, Probe Number = 2, T = 29.707000 C 14:04:58 Temperature Measurement, Probe Number = 3, T = 30.427000 C 14:04:59 Temperature Measurement, Probe Number = 4, T = 24.841000 C 14:05:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.360282 V 14:05:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.360282 (V, A, ohm, ...), Measured Value = 28.892800 (C, atm, Hz, ...) 14:05:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.492331 V 14:05:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.492331 (V, A, ohm, ...), Measured Value = 30.726821 (C, atm, Hz, ...) 14:05:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651551 V 14:05:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651551 (V, A, ohm, ...), Measured Value = 123.866340 (C, atm, Hz, ...) 14:05:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098417 V 14:05:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098417 (V, A, ohm, ...), Measured Value = 7.381297 (C, atm, Hz, ...) 14:05:06 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003242 V 14:05:06 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003242 (V, A, ohm, ...), Measured Value = 3.241729 (C, atm, Hz, ...) 14:05:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 219.97 P1 = Main (V), Value = 7.56 P2 = Top Right Coil, Value = 30.00 P3 = Bottom Right Coil, Value = 30.24 P4 = Top Left Coil, Value = 29.71 P5 = Bottom Left Coil, Value = 30.43 P6 = Ambient, Value = 24.84 P7 = Supply Temp(C), Value = 28.89 P8 = Return Temp(C), Value = 30.73 P9 = Supply Pres(psi), Value = 123.87 P10 = Return Pres(psi), Value = 7.38 P11 = Flow Rate(gpm), Value = 3.24 14:05:06 Magnetic Field Measurement Measuring the magnet strength... 14:05:06 Integrated Voltage Measurement... 14:05:07 Magnet Current for MAIN, Imag = 219.9701 A Vtrans = 2.199658 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:05:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012367624 Vs 14:05:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012372957 Vs 14:05:28 Magnet Current for MAIN, Imag = 219.9709 A Vtrans = 2.199666 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:05:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012367149 Vs 14:05:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012373942 Vs 14:05:47 Magnet Current for MAIN, Imag = 219.9703 A Vtrans = 2.199659 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:05:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012368015 Vs 14:06:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012372197 Vs 14:06:07 Magnet Current for MAIN, Imag = 219.9703 A Vtrans = 2.199659 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:06:16 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012366836 Vs 14:06:25 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.012372764 Vs 14:06:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.012370185 +- 0.000000272 Vs 14:06:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.012370185 +- 0.000000272 Vs BL = 0.12370185 +- 0.00000272 Tm 14:06:25 Integrated Voltage Measurement... 14:06:26 Magnet Current for MAIN, Imag = 219.9698 A Vtrans = 2.199654 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:06:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008256811 Vs 14:06:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008264637 Vs 14:06:47 Magnet Current for MAIN, Imag = 219.9699 A Vtrans = 2.199656 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:06:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008258047 Vs 14:07:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008262771 Vs 14:07:06 Magnet Current for MAIN, Imag = 219.9698 A Vtrans = 2.199654 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:07:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008257640 Vs 14:07:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008265302 Vs 14:07:26 Magnet Current for MAIN, Imag = 219.9704 A Vtrans = 2.199661 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:07:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008255886 Vs 14:07:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008266293 Vs 14:07:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008260923 +- 0.000000398 Vs 14:07:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.008260923 +- 0.000000398 Vs BL = 0.08260923 +- 0.00000398 Tm 14:07:44 Integrated Voltage Measurement... 14:07:45 Magnet Current for MAIN, Imag = 219.9690 A Vtrans = 2.199647 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:07:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004153739 Vs 14:08:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004165431 Vs 14:08:06 Magnet Current for MAIN, Imag = 219.9700 A Vtrans = 2.199657 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:08:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004153171 Vs 14:08:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004164627 Vs 14:08:26 Magnet Current for MAIN, Imag = 219.9694 A Vtrans = 2.199651 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:08:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004152414 Vs 14:08:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004164268 Vs 14:08:45 Magnet Current for MAIN, Imag = 219.9689 A Vtrans = 2.199645 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:08:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004153633 Vs 14:09:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004163124 Vs 14:09:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004158801 +- 0.000000504 Vs 14:09:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004158801 +- 0.000000504 Vs BL = 0.04158801 +- 0.00000504 Tm 14:09:04 Integrated Voltage Measurement... 14:09:05 Magnet Current for MAIN, Imag = 219.9678 A Vtrans = 2.199635 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:09:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004045237 Vs 14:09:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004038354 Vs 14:09:25 Magnet Current for MAIN, Imag = 219.9687 A Vtrans = 2.199644 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:09:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004042902 Vs 14:09:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004036902 Vs 14:09:45 Magnet Current for MAIN, Imag = 219.9685 A Vtrans = 2.199642 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:09:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004044085 Vs 14:10:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004037109 Vs 14:10:04 Magnet Current for MAIN, Imag = 219.9685 A Vtrans = 2.199642 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:10:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004044853 Vs 14:10:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004036106 Vs 14:10:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004040693 +- 0.000000688 Vs 14:10:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004040693 +- 0.000000688 Vs BL = -0.04040693 +- 0.00000688 Tm 14:10:23 Integrated Voltage Measurement... 14:10:24 Magnet Current for MAIN, Imag = 219.9684 A Vtrans = 2.199640 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:10:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008146973 Vs 14:10:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008137601 Vs 14:10:44 Magnet Current for MAIN, Imag = 219.9682 A Vtrans = 2.199639 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:10:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008147361 Vs 14:11:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008137733 Vs 14:11:04 Magnet Current for MAIN, Imag = 219.9678 A Vtrans = 2.199635 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:11:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008147333 Vs 14:11:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008137638 Vs 14:11:24 Magnet Current for MAIN, Imag = 219.9690 A Vtrans = 2.199647 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:11:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008146463 Vs 14:11:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008137999 Vs 14:11:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008142388 +- 0.000000132 Vs 14:11:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008142388 +- 0.000000132 Vs BL = -0.08142388 +- 0.00000132 Tm 14:11:42 Integrated Voltage Measurement... 14:11:43 Magnet Current for MAIN, Imag = 219.9682 A Vtrans = 2.199639 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:11:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012252537 Vs 14:12:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012244762 Vs 14:12:04 Magnet Current for MAIN, Imag = 219.9676 A Vtrans = 2.199633 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:12:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012251388 Vs 14:12:22 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012245065 Vs 14:12:23 Magnet Current for MAIN, Imag = 219.9696 A Vtrans = 2.199653 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:12:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012250132 Vs 14:12:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012246498 Vs 14:12:43 Magnet Current for MAIN, Imag = 219.9694 A Vtrans = 2.199651 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:12:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012250073 Vs 14:13:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012246491 Vs 14:13:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012248368 +- 0.000000165 Vs 14:13:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.012248368 +- 0.000000165 Vs BL = -0.12248368 +- 0.00000165 Tm 14:13:05 Position moved: 0.000000 m 14:13:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00060 0.00000 1 -4.10221 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.12370 0.00000 0.12366 0.00004 -0.0200000 0.08261 0.00000 0.08264 -0.00003 -0.0100000 0.04159 0.00001 0.04162 -0.00003 0.0100000 -0.04041 0.00001 -0.04042 0.00002 0.0200000 -0.08142 0.00000 -0.08145 0.00002 0.0300000 -0.12248 0.00000 -0.12247 -0.00001 14:13:05 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.12370 0.00000 -0.0200 0.08261 0.00000 -0.0100 0.04159 0.00001 0.0100 -0.04041 0.00001 0.0200 -0.08142 0.00000 0.0300 -0.12248 0.00000 SL = -4.1022063 +- 0.0000546 Tm^2/m^n 14:13:05 Quadrupole Strength Calculation Check Slope = -4.102206 Tm/m, Inter = 0.000597 Tm, Sig_slope = 0.000638 Tm/m, Est_sig = 0.000034 Tm GL = -4.102206 +- 0.000638 T 14:13:05 Magnet Strength Measurement Harmonic Number = 2 SL = -4.1022063 +- 0.0000546 Tm^2/m^n 14:13:08 Position moved: 0.000000 m 14:13:08 Magnet system MAIN current ramping to 200.0000 A... 14:13:32 Magnet Current for MAIN, Imag = 199.9916 A Vtrans = 1.999873 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:13:32 Main (V) Voltage Measurement, V = 6.864793 V 14:13:33 Temperature Measurement, Probe Number = 0, T = 29.804000 C 14:13:37 Temperature Measurement, Probe Number = 1, T = 30.051000 C 14:13:38 Temperature Measurement, Probe Number = 2, T = 29.586000 C 14:13:39 Temperature Measurement, Probe Number = 3, T = 30.216000 C 14:13:40 Temperature Measurement, Probe Number = 4, T = 24.911000 C 14:13:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.361788 V 14:13:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361788 (V, A, ohm, ...), Measured Value = 28.913719 (C, atm, Hz, ...) 14:13:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.473149 V 14:13:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.473149 (V, A, ohm, ...), Measured Value = 30.460407 (C, atm, Hz, ...) 14:13:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.672577 V 14:13:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.672577 (V, A, ohm, ...), Measured Value = 125.443297 (C, atm, Hz, ...) 14:13:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098183 V 14:13:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098183 (V, A, ohm, ...), Measured Value = 7.363755 (C, atm, Hz, ...) 14:13:46 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003222 V 14:13:46 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003222 (V, A, ohm, ...), Measured Value = 3.221983 (C, atm, Hz, ...) 14:13:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = Main (V), Value = 6.86 P2 = Top Right Coil, Value = 29.80 P3 = Bottom Right Coil, Value = 30.05 P4 = Top Left Coil, Value = 29.59 P5 = Bottom Left Coil, Value = 30.22 P6 = Ambient, Value = 24.91 P7 = Supply Temp(C), Value = 28.91 P8 = Return Temp(C), Value = 30.46 P9 = Supply Pres(psi), Value = 125.44 P10 = Return Pres(psi), Value = 7.36 P11 = Flow Rate(gpm), Value = 3.22 14:13:46 Magnetic Field Measurement Measuring the magnet strength... 14:13:46 Integrated Voltage Measurement... 14:13:47 Magnet Current for MAIN, Imag = 199.9923 A Vtrans = 1.999880 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:13:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011251493 Vs 14:14:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011256704 Vs 14:14:08 Magnet Current for MAIN, Imag = 199.9922 A Vtrans = 1.999878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:14:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011252394 Vs 14:14:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011254408 Vs 14:14:27 Magnet Current for MAIN, Imag = 199.9928 A Vtrans = 1.999885 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:14:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011251358 Vs 14:14:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011254960 Vs 14:14:47 Magnet Current for MAIN, Imag = 199.9925 A Vtrans = 1.999882 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:14:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011251226 Vs 14:15:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.011255938 Vs 14:15:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.011253560 +- 0.000000345 Vs 14:15:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.011253560 +- 0.000000345 Vs BL = 0.11253560 +- 0.00000345 Tm 14:15:06 Integrated Voltage Measurement... 14:15:07 Magnet Current for MAIN, Imag = 199.9916 A Vtrans = 1.999873 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:15:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007510136 Vs 14:15:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007519319 Vs 14:15:27 Magnet Current for MAIN, Imag = 199.9911 A Vtrans = 1.999868 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:15:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007511149 Vs 14:15:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007517976 Vs 14:15:47 Magnet Current for MAIN, Imag = 199.9922 A Vtrans = 1.999878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:15:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007511235 Vs 14:16:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007518031 Vs 14:16:06 Magnet Current for MAIN, Imag = 199.9911 A Vtrans = 1.999868 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:16:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007510728 Vs 14:16:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007518289 Vs 14:16:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007514608 +- 0.000000082 Vs 14:16:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007514608 +- 0.000000082 Vs BL = 0.07514608 +- 0.00000082 Tm 14:16:25 Integrated Voltage Measurement... 14:16:26 Magnet Current for MAIN, Imag = 199.9914 A Vtrans = 1.999871 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:16:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003779502 Vs 14:16:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003787247 Vs 14:16:46 Magnet Current for MAIN, Imag = 199.9924 A Vtrans = 1.999881 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:16:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003779845 Vs 14:17:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003786510 Vs 14:17:06 Magnet Current for MAIN, Imag = 199.9922 A Vtrans = 1.999878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:17:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003780223 Vs 14:17:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003786356 Vs 14:17:25 Magnet Current for MAIN, Imag = 199.9919 A Vtrans = 1.999876 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:17:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003777032 Vs 14:17:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003787711 Vs 14:17:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003783053 +- 0.000000400 Vs 14:17:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003783053 +- 0.000000400 Vs BL = 0.03783053 +- 0.00000400 Tm 14:17:44 Integrated Voltage Measurement... 14:17:45 Magnet Current for MAIN, Imag = 199.9918 A Vtrans = 1.999874 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:17:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003678947 Vs 14:18:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003675583 Vs 14:18:06 Magnet Current for MAIN, Imag = 199.9919 A Vtrans = 1.999876 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:18:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003677320 Vs 14:18:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003686395 Vs 14:18:25 Magnet Current for MAIN, Imag = 199.9919 A Vtrans = 1.999876 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:18:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003677961 Vs 14:18:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003674720 Vs 14:18:45 Magnet Current for MAIN, Imag = 199.9922 A Vtrans = 1.999878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:18:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003677899 Vs 14:19:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003675197 Vs 14:19:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003678003 +- 0.000002252 Vs 14:19:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003678003 +- 0.000002252 Vs BL = -0.03678003 +- 0.00002252 Tm 14:19:03 Integrated Voltage Measurement... 14:19:04 Magnet Current for MAIN, Imag = 199.9928 A Vtrans = 1.999885 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:19:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007409522 Vs 14:19:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007405668 Vs 14:19:25 Magnet Current for MAIN, Imag = 199.9927 A Vtrans = 1.999883 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:19:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007410054 Vs 14:19:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007406594 Vs 14:19:44 Magnet Current for MAIN, Imag = 199.9929 A Vtrans = 1.999886 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:19:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007409450 Vs 14:20:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007406731 Vs 14:20:04 Magnet Current for MAIN, Imag = 199.9925 A Vtrans = 1.999882 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:20:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007408589 Vs 14:20:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007407171 Vs 14:20:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007407972 +- 0.000000269 Vs 14:20:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007407972 +- 0.000000269 Vs BL = -0.07407972 +- 0.00000269 Tm 14:20:22 Integrated Voltage Measurement... 14:20:23 Magnet Current for MAIN, Imag = 199.9928 A Vtrans = 1.999885 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:20:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011144708 Vs 14:20:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011141169 Vs 14:20:44 Magnet Current for MAIN, Imag = 199.9920 A Vtrans = 1.999877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:20:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011147066 Vs 14:21:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011140698 Vs 14:21:04 Magnet Current for MAIN, Imag = 199.9916 A Vtrans = 1.999873 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:21:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011145672 Vs 14:21:22 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011140271 Vs 14:21:23 Magnet Current for MAIN, Imag = 199.9929 A Vtrans = 1.999886 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:21:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011145301 Vs 14:21:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.011141426 Vs 14:21:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.011143289 +- 0.000000381 Vs 14:21:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.011143289 +- 0.000000381 Vs BL = -0.11143289 +- 0.00000381 Tm 14:21:46 Position moved: 0.000000 m 14:21:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00054 0.00000 1 -3.73203 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.11254 0.00000 0.11250 0.00004 -0.0200000 0.07515 0.00000 0.07518 -0.00003 -0.0100000 0.03783 0.00000 0.03786 -0.00003 0.0100000 -0.03678 0.00002 -0.03678 0.00000 0.0200000 -0.07408 0.00000 -0.07410 0.00002 0.0300000 -0.11143 0.00000 -0.11142 -0.00001 14:21:46 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.11254 0.00000 -0.0200 0.07515 0.00000 -0.0100 0.03783 0.00000 0.0100 -0.03678 0.00002 0.0200 -0.07408 0.00000 0.0300 -0.11143 0.00000 SL = -3.7320272 +- 0.0001005 Tm^2/m^n 14:21:46 Quadrupole Strength Calculation Check Slope = -3.732027 Tm/m, Inter = 0.000537 Tm, Sig_slope = 0.000582 Tm/m, Est_sig = 0.000031 Tm GL = -3.732027 +- 0.000582 T 14:21:46 Magnet Strength Measurement Harmonic Number = 2 SL = -3.7320272 +- 0.0001005 Tm^2/m^n 14:21:48 Position moved: 0.000000 m 14:21:48 Magnet system MAIN current ramping to 180.0000 A... 14:22:12 Magnet Current for MAIN, Imag = 180.0026 A Vtrans = 1.799983 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:22:13 Main (V) Voltage Measurement, V = 6.174877 V 14:22:14 Temperature Measurement, Probe Number = 0, T = 29.591000 C 14:22:17 Temperature Measurement, Probe Number = 1, T = 29.890000 C 14:22:18 Temperature Measurement, Probe Number = 2, T = 29.497000 C 14:22:19 Temperature Measurement, Probe Number = 3, T = 29.998000 C 14:22:20 Temperature Measurement, Probe Number = 4, T = 24.933000 C 14:22:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.362627 V 14:22:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362627 (V, A, ohm, ...), Measured Value = 28.925371 (C, atm, Hz, ...) 14:22:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.455933 V 14:22:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.455933 (V, A, ohm, ...), Measured Value = 30.221286 (C, atm, Hz, ...) 14:22:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660058 V 14:22:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660058 (V, A, ohm, ...), Measured Value = 124.504387 (C, atm, Hz, ...) 14:22:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097942 V 14:22:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097942 (V, A, ohm, ...), Measured Value = 7.345642 (C, atm, Hz, ...) 14:22:27 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003228 V 14:22:27 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003228 (V, A, ohm, ...), Measured Value = 3.227956 (C, atm, Hz, ...) 14:22:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.00 P1 = Main (V), Value = 6.17 P2 = Top Right Coil, Value = 29.59 P3 = Bottom Right Coil, Value = 29.89 P4 = Top Left Coil, Value = 29.50 P5 = Bottom Left Coil, Value = 30.00 P6 = Ambient, Value = 24.93 P7 = Supply Temp(C), Value = 28.93 P8 = Return Temp(C), Value = 30.22 P9 = Supply Pres(psi), Value = 124.50 P10 = Return Pres(psi), Value = 7.35 P11 = Flow Rate(gpm), Value = 3.23 14:22:27 Magnetic Field Measurement Measuring the magnet strength... 14:22:27 Integrated Voltage Measurement... 14:22:28 Magnet Current for MAIN, Imag = 180.0035 A Vtrans = 1.799991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:22:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010134776 Vs 14:22:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010136171 Vs 14:22:48 Magnet Current for MAIN, Imag = 180.0031 A Vtrans = 1.799988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:22:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010133866 Vs 14:23:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010136880 Vs 14:23:08 Magnet Current for MAIN, Imag = 180.0036 A Vtrans = 1.799993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:23:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010133716 Vs 14:23:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010135773 Vs 14:23:27 Magnet Current for MAIN, Imag = 180.0032 A Vtrans = 1.799989 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:23:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010135683 Vs 14:23:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010134454 Vs 14:23:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010135165 +- 0.000000285 Vs 14:23:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010135165 +- 0.000000285 Vs BL = 0.10135165 +- 0.00000285 Tm 14:23:46 Integrated Voltage Measurement... 14:23:47 Magnet Current for MAIN, Imag = 180.0031 A Vtrans = 1.799988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:23:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006767409 Vs 14:24:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006768406 Vs 14:24:07 Magnet Current for MAIN, Imag = 180.0036 A Vtrans = 1.799993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:24:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006767948 Vs 14:24:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006768130 Vs 14:24:27 Magnet Current for MAIN, Imag = 180.0031 A Vtrans = 1.799988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:24:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006767168 Vs 14:24:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006769550 Vs 14:24:46 Magnet Current for MAIN, Imag = 180.0028 A Vtrans = 1.799985 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:24:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006766376 Vs 14:25:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006771883 Vs 14:25:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006768359 +- 0.000000474 Vs 14:25:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006768359 +- 0.000000474 Vs BL = 0.06768359 +- 0.00000474 Tm 14:25:05 Integrated Voltage Measurement... 14:25:06 Magnet Current for MAIN, Imag = 180.0031 A Vtrans = 1.799988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:25:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003404569 Vs 14:25:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003409567 Vs 14:25:27 Magnet Current for MAIN, Imag = 180.0033 A Vtrans = 1.799990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:25:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003404406 Vs 14:25:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003410017 Vs 14:25:46 Magnet Current for MAIN, Imag = 180.0037 A Vtrans = 1.799994 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:25:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003404944 Vs 14:26:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003411452 Vs 14:26:06 Magnet Current for MAIN, Imag = 180.0035 A Vtrans = 1.799991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:26:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003403252 Vs 14:26:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003410564 Vs 14:26:24 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003407346 +- 0.000000503 Vs 14:26:24 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003407346 +- 0.000000503 Vs BL = 0.03407346 +- 0.00000503 Tm 14:26:24 Integrated Voltage Measurement... 14:26:25 Magnet Current for MAIN, Imag = 180.0040 A Vtrans = 1.799996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:26:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003314020 Vs 14:26:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003309501 Vs 14:26:46 Magnet Current for MAIN, Imag = 180.0036 A Vtrans = 1.799993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:26:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003313601 Vs 14:27:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003308301 Vs 14:27:06 Magnet Current for MAIN, Imag = 180.0038 A Vtrans = 1.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:27:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003314674 Vs 14:27:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003308792 Vs 14:27:25 Magnet Current for MAIN, Imag = 180.0035 A Vtrans = 1.799991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:27:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003315509 Vs 14:27:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003308390 Vs 14:27:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003311599 +- 0.000000383 Vs 14:27:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003311599 +- 0.000000383 Vs BL = -0.03311599 +- 0.00000383 Tm 14:27:43 Integrated Voltage Measurement... 14:27:44 Magnet Current for MAIN, Imag = 180.0038 A Vtrans = 1.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:27:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006676040 Vs 14:28:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006669061 Vs 14:28:05 Magnet Current for MAIN, Imag = 180.0031 A Vtrans = 1.799988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:28:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006676437 Vs 14:28:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006667666 Vs 14:28:25 Magnet Current for MAIN, Imag = 180.0032 A Vtrans = 1.799989 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:28:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006677927 Vs 14:28:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006666953 Vs 14:28:44 Magnet Current for MAIN, Imag = 180.0038 A Vtrans = 1.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:28:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006677903 Vs 14:29:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006667575 Vs 14:29:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006672445 +- 0.000000251 Vs 14:29:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006672445 +- 0.000000251 Vs BL = -0.06672445 +- 0.00000251 Tm 14:29:03 Integrated Voltage Measurement... 14:29:04 Magnet Current for MAIN, Imag = 180.0033 A Vtrans = 1.799990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:29:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.010040266 Vs 14:29:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.010032471 Vs 14:29:24 Magnet Current for MAIN, Imag = 180.0032 A Vtrans = 1.799989 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:29:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.010040307 Vs 14:29:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.010034028 Vs 14:29:44 Magnet Current for MAIN, Imag = 180.0038 A Vtrans = 1.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:29:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.010040104 Vs 14:30:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.010033040 Vs 14:30:04 Magnet Current for MAIN, Imag = 180.0035 A Vtrans = 1.799991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:30:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.010039912 Vs 14:30:22 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.010033987 Vs 14:30:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.010036764 +- 0.000000312 Vs 14:30:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.010036764 +- 0.000000312 Vs BL = -0.10036764 +- 0.00000312 Tm 14:30:26 Position moved: 0.000000 m 14:30:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00048 0.00000 1 -3.36130 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.10135 0.00000 0.10132 0.00003 -0.0200000 0.06768 0.00000 0.06771 -0.00003 -0.0100000 0.03407 0.00001 0.03410 -0.00002 0.0100000 -0.03312 0.00000 -0.03313 0.00001 0.0200000 -0.06672 0.00000 -0.06674 0.00002 0.0300000 -0.10037 0.00000 -0.10036 -0.00001 14:30:26 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.10135 0.00000 -0.0200 0.06768 0.00000 -0.0100 0.03407 0.00001 0.0100 -0.03312 0.00000 0.0200 -0.06672 0.00000 0.0300 -0.10037 0.00000 SL = -3.3612979 +- 0.0000635 Tm^2/m^n 14:30:26 Quadrupole Strength Calculation Check Slope = -3.361298 Tm/m, Inter = 0.000483 Tm, Sig_slope = 0.000492 Tm/m, Est_sig = 0.000026 Tm GL = -3.361298 +- 0.000492 T 14:30:26 Magnet Strength Measurement Harmonic Number = 2 SL = -3.3612979 +- 0.0000635 Tm^2/m^n 14:30:29 Position moved: 0.000000 m 14:30:29 Magnet system MAIN current ramping to 160.0000 A... 14:30:52 Magnet Current for MAIN, Imag = 160.0294 A Vtrans = 1.600251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:30:53 Main (V) Voltage Measurement, V = 5.486602 V 14:30:54 Temperature Measurement, Probe Number = 0, T = 29.428000 C 14:30:58 Temperature Measurement, Probe Number = 1, T = 29.706000 C 14:30:59 Temperature Measurement, Probe Number = 2, T = 29.371000 C 14:31:00 Temperature Measurement, Probe Number = 3, T = 29.827000 C 14:31:00 Temperature Measurement, Probe Number = 4, T = 24.946000 C 14:31:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.362641 V 14:31:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362641 (V, A, ohm, ...), Measured Value = 28.925565 (C, atm, Hz, ...) 14:31:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.439010 V 14:31:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.439010 (V, A, ohm, ...), Measured Value = 29.986244 (C, atm, Hz, ...) 14:31:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656664 V 14:31:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656664 (V, A, ohm, ...), Measured Value = 124.249763 (C, atm, Hz, ...) 14:31:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098106 V 14:31:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098106 (V, A, ohm, ...), Measured Value = 7.357942 (C, atm, Hz, ...) 14:31:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003202 V 14:31:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003202 (V, A, ohm, ...), Measured Value = 3.201674 (C, atm, Hz, ...) 14:31:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.03 P1 = Main (V), Value = 5.49 P2 = Top Right Coil, Value = 29.43 P3 = Bottom Right Coil, Value = 29.71 P4 = Top Left Coil, Value = 29.37 P5 = Bottom Left Coil, Value = 29.83 P6 = Ambient, Value = 24.95 P7 = Supply Temp(C), Value = 28.93 P8 = Return Temp(C), Value = 29.99 P9 = Supply Pres(psi), Value = 124.25 P10 = Return Pres(psi), Value = 7.36 P11 = Flow Rate(gpm), Value = 3.20 14:31:07 Magnetic Field Measurement Measuring the magnet strength... 14:31:07 Integrated Voltage Measurement... 14:31:08 Magnet Current for MAIN, Imag = 160.0294 A Vtrans = 1.600251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:31:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.009014777 Vs 14:31:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.009019421 Vs 14:31:29 Magnet Current for MAIN, Imag = 160.0295 A Vtrans = 1.600252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:31:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.009013909 Vs 14:31:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.009019389 Vs 14:31:48 Magnet Current for MAIN, Imag = 160.0291 A Vtrans = 1.600248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:31:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.009015023 Vs 14:32:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.009019140 Vs 14:32:08 Magnet Current for MAIN, Imag = 160.0290 A Vtrans = 1.600247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:32:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.009014398 Vs 14:32:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.009017308 Vs 14:32:26 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.009016671 +- 0.000000505 Vs 14:32:26 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.009016671 +- 0.000000505 Vs BL = 0.09016671 +- 0.00000505 Tm 14:32:26 Integrated Voltage Measurement... 14:32:27 Magnet Current for MAIN, Imag = 160.0291 A Vtrans = 1.600248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:32:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006019371 Vs 14:32:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006023252 Vs 14:32:48 Magnet Current for MAIN, Imag = 160.0293 A Vtrans = 1.600249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:32:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006016847 Vs 14:33:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006025090 Vs 14:33:07 Magnet Current for MAIN, Imag = 160.0298 A Vtrans = 1.600254 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:33:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006017140 Vs 14:33:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006025555 Vs 14:33:27 Magnet Current for MAIN, Imag = 160.0293 A Vtrans = 1.600249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:33:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006018277 Vs 14:33:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006023362 Vs 14:33:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006021112 +- 0.000000224 Vs 14:33:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006021112 +- 0.000000224 Vs BL = 0.06021112 +- 0.00000224 Tm 14:33:45 Integrated Voltage Measurement... 14:33:46 Magnet Current for MAIN, Imag = 160.0290 A Vtrans = 1.600247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:33:57 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003028686 Vs 14:34:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003035109 Vs 14:34:07 Magnet Current for MAIN, Imag = 160.0288 A Vtrans = 1.600244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:34:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003027050 Vs 14:34:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003034320 Vs 14:34:26 Magnet Current for MAIN, Imag = 160.0291 A Vtrans = 1.600248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:34:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003027888 Vs 14:34:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003033412 Vs 14:34:46 Magnet Current for MAIN, Imag = 160.0291 A Vtrans = 1.600248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:34:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003028899 Vs 14:35:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003032996 Vs 14:35:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003031045 +- 0.000000505 Vs 14:35:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003031045 +- 0.000000505 Vs BL = 0.03031045 +- 0.00000505 Tm 14:35:05 Integrated Voltage Measurement... 14:35:06 Magnet Current for MAIN, Imag = 160.0295 A Vtrans = 1.600252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:35:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002949175 Vs 14:35:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002942694 Vs 14:35:26 Magnet Current for MAIN, Imag = 160.0294 A Vtrans = 1.600251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:35:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002950395 Vs 14:35:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002942166 Vs 14:35:46 Magnet Current for MAIN, Imag = 160.0295 A Vtrans = 1.600252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:35:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002950004 Vs 14:36:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002942934 Vs 14:36:05 Magnet Current for MAIN, Imag = 160.0289 A Vtrans = 1.600246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:36:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002950835 Vs 14:36:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002942813 Vs 14:36:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002946377 +- 0.000000321 Vs 14:36:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002946377 +- 0.000000321 Vs BL = -0.02946377 +- 0.00000321 Tm 14:36:24 Integrated Voltage Measurement... 14:36:25 Magnet Current for MAIN, Imag = 160.0293 A Vtrans = 1.600249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:36:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005939711 Vs 14:36:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005933497 Vs 14:36:45 Magnet Current for MAIN, Imag = 160.0293 A Vtrans = 1.600249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:36:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005938508 Vs 14:37:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005933065 Vs 14:37:05 Magnet Current for MAIN, Imag = 160.0290 A Vtrans = 1.600247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:37:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005939169 Vs 14:37:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005933333 Vs 14:37:24 Magnet Current for MAIN, Imag = 160.0296 A Vtrans = 1.600253 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:37:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005939818 Vs 14:37:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005933680 Vs 14:37:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005936348 +- 0.000000371 Vs 14:37:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005936348 +- 0.000000371 Vs BL = -0.05936348 +- 0.00000371 Tm 14:37:43 Integrated Voltage Measurement... 14:37:44 Magnet Current for MAIN, Imag = 160.0291 A Vtrans = 1.600248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:37:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008934820 Vs 14:38:04 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008927054 Vs 14:38:05 Magnet Current for MAIN, Imag = 160.0295 A Vtrans = 1.600252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:38:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008933528 Vs 14:38:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008928425 Vs 14:38:24 Magnet Current for MAIN, Imag = 160.0293 A Vtrans = 1.600249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:38:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008931810 Vs 14:38:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008928918 Vs 14:38:44 Magnet Current for MAIN, Imag = 160.0293 A Vtrans = 1.600249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:38:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008932877 Vs 14:39:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.008928107 Vs 14:39:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.008930693 +- 0.000000269 Vs 14:39:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008930693 +- 0.000000269 Vs BL = -0.08930693 +- 0.00000269 Tm 14:39:06 Position moved: 0.000000 m 14:39:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00043 0.00000 1 -2.99052 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.09017 0.00001 0.09014 0.00003 -0.0200000 0.06021 0.00000 0.06024 -0.00002 -0.0100000 0.03031 0.00001 0.03033 -0.00002 0.0100000 -0.02946 0.00000 -0.02948 0.00002 0.0200000 -0.05936 0.00000 -0.05938 0.00002 0.0300000 -0.08931 0.00000 -0.08929 -0.00002 14:39:06 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.09017 0.00001 -0.0200 0.06021 0.00000 -0.0100 0.03031 0.00001 0.0100 -0.02946 0.00000 0.0200 -0.05936 0.00000 0.0300 -0.08931 0.00000 SL = -2.9905154 +- 0.0000720 Tm^2/m^n 14:39:06 Quadrupole Strength Calculation Check Slope = -2.990515 Tm/m, Inter = 0.000426 Tm, Sig_slope = 0.000489 Tm/m, Est_sig = 0.000026 Tm GL = -2.990515 +- 0.000489 T 14:39:06 Magnet Strength Measurement Harmonic Number = 2 SL = -2.9905154 +- 0.0000720 Tm^2/m^n 14:39:09 Position moved: 0.000000 m 14:39:09 Magnet system MAIN current ramping to 140.0000 A... 14:39:32 Magnet Current for MAIN, Imag = 139.9524 A Vtrans = 1.399480 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:39:33 Main (V) Voltage Measurement, V = 4.795583 V 14:39:34 Temperature Measurement, Probe Number = 0, T = 29.265000 C 14:39:38 Temperature Measurement, Probe Number = 1, T = 29.551000 C 14:39:39 Temperature Measurement, Probe Number = 2, T = 29.281000 C 14:39:40 Temperature Measurement, Probe Number = 3, T = 29.619000 C 14:39:41 Temperature Measurement, Probe Number = 4, T = 25.113000 C 14:39:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.362093 V 14:39:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362093 (V, A, ohm, ...), Measured Value = 28.917957 (C, atm, Hz, ...) 14:39:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.424296 V 14:39:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.424296 (V, A, ohm, ...), Measured Value = 29.781883 (C, atm, Hz, ...) 14:39:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654246 V 14:39:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654246 (V, A, ohm, ...), Measured Value = 124.068442 (C, atm, Hz, ...) 14:39:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097983 V 14:39:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097983 (V, A, ohm, ...), Measured Value = 7.348695 (C, atm, Hz, ...) 14:39:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003228 V 14:39:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003228 (V, A, ohm, ...), Measured Value = 3.228418 (C, atm, Hz, ...) 14:39:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.95 P1 = Main (V), Value = 4.80 P2 = Top Right Coil, Value = 29.27 P3 = Bottom Right Coil, Value = 29.55 P4 = Top Left Coil, Value = 29.28 P5 = Bottom Left Coil, Value = 29.62 P6 = Ambient, Value = 25.11 P7 = Supply Temp(C), Value = 28.92 P8 = Return Temp(C), Value = 29.78 P9 = Supply Pres(psi), Value = 124.07 P10 = Return Pres(psi), Value = 7.35 P11 = Flow Rate(gpm), Value = 3.23 14:39:47 Magnetic Field Measurement Measuring the magnet strength... 14:39:47 Integrated Voltage Measurement... 14:39:48 Magnet Current for MAIN, Imag = 139.9524 A Vtrans = 1.399480 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:39:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007891623 Vs 14:40:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007893882 Vs 14:40:09 Magnet Current for MAIN, Imag = 139.9527 A Vtrans = 1.399484 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:40:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007890905 Vs 14:40:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007892889 Vs 14:40:28 Magnet Current for MAIN, Imag = 139.9525 A Vtrans = 1.399482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:40:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007890674 Vs 14:40:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007893357 Vs 14:40:48 Magnet Current for MAIN, Imag = 139.9519 A Vtrans = 1.399475 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:40:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007890565 Vs 14:41:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.007893885 Vs 14:41:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.007892223 +- 0.000000328 Vs 14:41:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007892223 +- 0.000000328 Vs BL = 0.07892223 +- 0.00000328 Tm 14:41:06 Integrated Voltage Measurement... 14:41:07 Magnet Current for MAIN, Imag = 139.9523 A Vtrans = 1.399479 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:41:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005268214 Vs 14:41:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005271158 Vs 14:41:28 Magnet Current for MAIN, Imag = 139.9525 A Vtrans = 1.399482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:41:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005268178 Vs 14:41:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005271861 Vs 14:41:47 Magnet Current for MAIN, Imag = 139.9527 A Vtrans = 1.399484 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:41:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005267472 Vs 14:42:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005272334 Vs 14:42:07 Magnet Current for MAIN, Imag = 139.9525 A Vtrans = 1.399482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:42:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005268292 Vs 14:42:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005272919 Vs 14:42:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005270054 +- 0.000000341 Vs 14:42:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005270054 +- 0.000000341 Vs BL = 0.05270054 +- 0.00000341 Tm 14:42:25 Integrated Voltage Measurement... 14:42:26 Magnet Current for MAIN, Imag = 139.9530 A Vtrans = 1.399487 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:42:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002649629 Vs 14:42:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002657093 Vs 14:42:47 Magnet Current for MAIN, Imag = 139.9523 A Vtrans = 1.399479 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:42:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002656261 Vs 14:43:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002655486 Vs 14:43:06 Magnet Current for MAIN, Imag = 139.9530 A Vtrans = 1.399487 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:43:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002650231 Vs 14:43:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002655312 Vs 14:43:26 Magnet Current for MAIN, Imag = 139.9526 A Vtrans = 1.399483 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:43:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002648868 Vs 14:43:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002656140 Vs 14:43:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002653628 +- 0.000001333 Vs 14:43:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002653628 +- 0.000001333 Vs BL = 0.02653628 +- 0.00001333 Tm 14:43:45 Integrated Voltage Measurement... 14:43:46 Magnet Current for MAIN, Imag = 139.9526 A Vtrans = 1.399483 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:43:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002584155 Vs 14:44:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002576370 Vs 14:44:06 Magnet Current for MAIN, Imag = 139.9527 A Vtrans = 1.399484 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:44:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002583401 Vs 14:44:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002575292 Vs 14:44:26 Magnet Current for MAIN, Imag = 139.9526 A Vtrans = 1.399483 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:44:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002584439 Vs 14:44:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002574211 Vs 14:44:45 Magnet Current for MAIN, Imag = 139.9525 A Vtrans = 1.399482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:44:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002584551 Vs 14:45:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002573760 Vs 14:45:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002579522 +- 0.000000433 Vs 14:45:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002579522 +- 0.000000433 Vs BL = -0.02579522 +- 0.00000433 Tm 14:45:04 Integrated Voltage Measurement... 14:45:05 Magnet Current for MAIN, Imag = 139.9521 A Vtrans = 1.399478 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:45:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005200014 Vs 14:45:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005193713 Vs 14:45:25 Magnet Current for MAIN, Imag = 139.9531 A Vtrans = 1.399488 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:45:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005200262 Vs 14:45:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005194729 Vs 14:45:45 Magnet Current for MAIN, Imag = 139.9525 A Vtrans = 1.399482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:45:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005199190 Vs 14:46:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005196412 Vs 14:46:04 Magnet Current for MAIN, Imag = 139.9525 A Vtrans = 1.399482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:46:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005198762 Vs 14:46:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005194290 Vs 14:46:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005197172 +- 0.000000503 Vs 14:46:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005197172 +- 0.000000503 Vs BL = -0.05197172 +- 0.00000503 Tm 14:46:23 Integrated Voltage Measurement... 14:46:24 Magnet Current for MAIN, Imag = 139.9531 A Vtrans = 1.399488 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:46:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007818447 Vs 14:46:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007814731 Vs 14:46:45 Magnet Current for MAIN, Imag = 139.9526 A Vtrans = 1.399483 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:46:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007821734 Vs 14:47:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007814850 Vs 14:47:04 Magnet Current for MAIN, Imag = 139.9524 A Vtrans = 1.399480 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:47:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007819464 Vs 14:47:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007815358 Vs 14:47:24 Magnet Current for MAIN, Imag = 139.9519 A Vtrans = 1.399475 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:47:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007820680 Vs 14:47:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.007814018 Vs 14:47:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.007817410 +- 0.000000603 Vs 14:47:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007817410 +- 0.000000603 Vs BL = -0.07817410 +- 0.00000603 Tm 14:47:46 Position moved: 0.000000 m 14:47:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00037 0.00000 1 -2.61773 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.07892 0.00000 0.07890 0.00002 -0.0200000 0.05270 0.00000 0.05272 -0.00002 -0.0100000 0.02654 0.00001 0.02655 -0.00001 0.0100000 -0.02580 0.00000 -0.02581 0.00001 0.0200000 -0.05197 0.00001 -0.05198 0.00001 0.0300000 -0.07817 0.00001 -0.07816 -0.00001 14:47:46 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.07892 0.00000 -0.0200 0.05270 0.00000 -0.0100 0.02654 0.00001 0.0100 -0.02580 0.00000 0.0200 -0.05197 0.00001 0.0300 -0.07817 0.00001 SL = -2.6177321 +- 0.0000990 Tm^2/m^n 14:47:46 Quadrupole Strength Calculation Check Slope = -2.617732 Tm/m, Inter = 0.000370 Tm, Sig_slope = 0.000375 Tm/m, Est_sig = 0.000020 Tm GL = -2.617732 +- 0.000375 T 14:47:46 Magnet Strength Measurement Harmonic Number = 2 SL = -2.6177321 +- 0.0000990 Tm^2/m^n 14:47:49 Position moved: 0.000000 m 14:47:49 Magnet system MAIN current ramping to 120.0000 A... 14:48:12 Magnet Current for MAIN, Imag = 119.9752 A Vtrans = 1.199709 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:48:13 Main (V) Voltage Measurement, V = 4.109331 V 14:48:14 Temperature Measurement, Probe Number = 0, T = 29.167000 C 14:48:18 Temperature Measurement, Probe Number = 1, T = 29.422000 C 14:48:19 Temperature Measurement, Probe Number = 2, T = 29.210000 C 14:48:20 Temperature Measurement, Probe Number = 3, T = 29.477000 C 14:48:21 Temperature Measurement, Probe Number = 4, T = 25.198000 C 14:48:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.362721 V 14:48:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362721 (V, A, ohm, ...), Measured Value = 28.926678 (C, atm, Hz, ...) 14:48:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.410297 V 14:48:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.410297 (V, A, ohm, ...), Measured Value = 29.587460 (C, atm, Hz, ...) 14:48:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655756 V 14:48:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655756 (V, A, ohm, ...), Measured Value = 124.181700 (C, atm, Hz, ...) 14:48:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097703 V 14:48:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097703 (V, A, ohm, ...), Measured Value = 7.327718 (C, atm, Hz, ...) 14:48:27 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003218 V 14:48:27 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003218 (V, A, ohm, ...), Measured Value = 3.218054 (C, atm, Hz, ...) 14:48:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 119.98 P1 = Main (V), Value = 4.11 P2 = Top Right Coil, Value = 29.17 P3 = Bottom Right Coil, Value = 29.42 P4 = Top Left Coil, Value = 29.21 P5 = Bottom Left Coil, Value = 29.48 P6 = Ambient, Value = 25.20 P7 = Supply Temp(C), Value = 28.93 P8 = Return Temp(C), Value = 29.59 P9 = Supply Pres(psi), Value = 124.18 P10 = Return Pres(psi), Value = 7.33 P11 = Flow Rate(gpm), Value = 3.22 14:48:27 Magnetic Field Measurement Measuring the magnet strength... 14:48:27 Integrated Voltage Measurement... 14:48:28 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:48:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006764974 Vs 14:48:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006774724 Vs 14:48:49 Magnet Current for MAIN, Imag = 119.9761 A Vtrans = 1.199718 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:48:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006770691 Vs 14:49:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006775055 Vs 14:49:08 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:49:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006770652 Vs 14:49:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006775322 Vs 14:49:28 Magnet Current for MAIN, Imag = 119.9759 A Vtrans = 1.199715 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:49:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006772182 Vs 14:49:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006774070 Vs 14:49:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006772209 +- 0.000001365 Vs 14:49:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006772209 +- 0.000001365 Vs BL = 0.06772209 +- 0.00001365 Tm 14:49:46 Integrated Voltage Measurement... 14:49:47 Magnet Current for MAIN, Imag = 119.9756 A Vtrans = 1.199713 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:49:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004520019 Vs 14:50:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004525102 Vs 14:50:08 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:50:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004520673 Vs 14:50:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004523876 Vs 14:50:27 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:50:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004519410 Vs 14:50:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004524114 Vs 14:50:47 Magnet Current for MAIN, Imag = 119.9756 A Vtrans = 1.199713 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:50:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004521206 Vs 14:51:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004523474 Vs 14:51:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004522234 +- 0.000000292 Vs 14:51:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004522234 +- 0.000000292 Vs BL = 0.04522234 +- 0.00000292 Tm 14:51:06 Integrated Voltage Measurement... 14:51:07 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:51:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002274670 Vs 14:51:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002273834 Vs 14:51:27 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:51:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002277116 Vs 14:51:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002276614 Vs 14:51:47 Magnet Current for MAIN, Imag = 119.9756 A Vtrans = 1.199713 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:51:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002276304 Vs 14:52:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002276476 Vs 14:52:06 Magnet Current for MAIN, Imag = 119.9754 A Vtrans = 1.199710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:52:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002275810 Vs 14:52:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002277459 Vs 14:52:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002276035 +- 0.000001043 Vs 14:52:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002276035 +- 0.000001043 Vs BL = 0.02276035 +- 0.00001043 Tm 14:52:25 Integrated Voltage Measurement... 14:52:26 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:52:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002214704 Vs 14:52:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002211908 Vs 14:52:47 Magnet Current for MAIN, Imag = 119.9756 A Vtrans = 1.199713 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:52:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002214733 Vs 14:53:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002216779 Vs 14:53:06 Magnet Current for MAIN, Imag = 119.9755 A Vtrans = 1.199712 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:53:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002213646 Vs 14:53:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002214528 Vs 14:53:26 Magnet Current for MAIN, Imag = 119.9759 A Vtrans = 1.199715 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:53:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002216592 Vs 14:53:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002211216 Vs 14:53:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002214263 +- 0.000000909 Vs 14:53:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002214263 +- 0.000000909 Vs BL = -0.02214263 +- 0.00000909 Tm 14:53:44 Integrated Voltage Measurement... 14:53:45 Magnet Current for MAIN, Imag = 119.9755 A Vtrans = 1.199712 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:53:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004461876 Vs 14:54:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004461097 Vs 14:54:06 Magnet Current for MAIN, Imag = 119.9764 A Vtrans = 1.199721 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:54:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004457358 Vs 14:54:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004460052 Vs 14:54:25 Magnet Current for MAIN, Imag = 119.9759 A Vtrans = 1.199715 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:54:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004460996 Vs 14:54:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004459404 Vs 14:54:45 Magnet Current for MAIN, Imag = 119.9755 A Vtrans = 1.199712 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:54:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004463170 Vs 14:55:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004458636 Vs 14:55:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004460324 +- 0.000001040 Vs 14:55:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004460324 +- 0.000001040 Vs BL = -0.04460324 +- 0.00001040 Tm 14:55:03 Integrated Voltage Measurement... 14:55:04 Magnet Current for MAIN, Imag = 119.9768 A Vtrans = 1.199724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:55:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006709873 Vs 14:55:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006706388 Vs 14:55:25 Magnet Current for MAIN, Imag = 119.9761 A Vtrans = 1.199718 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:55:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006712575 Vs 14:55:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006705332 Vs 14:55:44 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:55:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006712859 Vs 14:56:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006704214 Vs 14:56:04 Magnet Current for MAIN, Imag = 119.9757 A Vtrans = 1.199714 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:56:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006713205 Vs 14:56:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006706656 Vs 14:56:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006708888 +- 0.000000669 Vs 14:56:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006708888 +- 0.000000669 Vs BL = -0.06708888 +- 0.00000669 Tm 14:56:26 Position moved: 0.000000 m 14:56:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00031 0.00000 1 -2.24638 0.00019 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.06772 0.00001 0.06770 0.00002 -0.0200000 0.04522 0.00000 0.04524 -0.00002 -0.0100000 0.02276 0.00001 0.02278 -0.00002 0.0100000 -0.02214 0.00001 -0.02215 0.00001 0.0200000 -0.04460 0.00001 -0.04462 0.00001 0.0300000 -0.06709 0.00001 -0.06708 -0.00001 14:56:26 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.06772 0.00001 -0.0200 0.04522 0.00000 -0.0100 0.02276 0.00001 0.0100 -0.02214 0.00001 0.0200 -0.04460 0.00001 0.0300 -0.06709 0.00001 SL = -2.2463823 +- 0.0001869 Tm^2/m^n 14:56:26 Quadrupole Strength Calculation Check Slope = -2.246382 Tm/m, Inter = 0.000312 Tm, Sig_slope = 0.000329 Tm/m, Est_sig = 0.000017 Tm GL = -2.246382 +- 0.000329 T 14:56:26 Magnet Strength Measurement Harmonic Number = 2 SL = -2.2463823 +- 0.0001869 Tm^2/m^n 14:56:29 Position moved: 0.000000 m 14:56:29 Magnet system MAIN current ramping to 100.0000 A... 14:56:53 Magnet Current for MAIN, Imag = 99.9909 A Vtrans = 0.999866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:56:53 Main (V) Voltage Measurement, V = 3.423351 V 14:56:54 Temperature Measurement, Probe Number = 0, T = 29.051000 C 14:56:58 Temperature Measurement, Probe Number = 1, T = 29.325000 C 14:56:59 Temperature Measurement, Probe Number = 2, T = 29.155000 C 14:57:00 Temperature Measurement, Probe Number = 3, T = 29.364000 C 14:57:01 Temperature Measurement, Probe Number = 4, T = 25.305000 C 14:57:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.361803 V 14:57:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361803 (V, A, ohm, ...), Measured Value = 28.913932 (C, atm, Hz, ...) 14:57:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.398845 V 14:57:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.398845 (V, A, ohm, ...), Measured Value = 29.428399 (C, atm, Hz, ...) 14:57:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667811 V 14:57:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667811 (V, A, ohm, ...), Measured Value = 125.085810 (C, atm, Hz, ...) 14:57:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097890 V 14:57:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097890 (V, A, ohm, ...), Measured Value = 7.341735 (C, atm, Hz, ...) 14:57:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003223 V 14:57:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003223 (V, A, ohm, ...), Measured Value = 3.223004 (C, atm, Hz, ...) 14:57:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 99.99 P1 = Main (V), Value = 3.42 P2 = Top Right Coil, Value = 29.05 P3 = Bottom Right Coil, Value = 29.32 P4 = Top Left Coil, Value = 29.16 P5 = Bottom Left Coil, Value = 29.36 P6 = Ambient, Value = 25.30 P7 = Supply Temp(C), Value = 28.91 P8 = Return Temp(C), Value = 29.43 P9 = Supply Pres(psi), Value = 125.09 P10 = Return Pres(psi), Value = 7.34 P11 = Flow Rate(gpm), Value = 3.22 14:57:07 Magnetic Field Measurement Measuring the magnet strength... 14:57:07 Integrated Voltage Measurement... 14:57:08 Magnet Current for MAIN, Imag = 99.9905 A Vtrans = 0.999862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:57:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005650874 Vs 14:57:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005653516 Vs 14:57:29 Magnet Current for MAIN, Imag = 99.9909 A Vtrans = 0.999866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:57:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005649432 Vs 14:57:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005656020 Vs 14:57:49 Magnet Current for MAIN, Imag = 99.9908 A Vtrans = 0.999864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:57:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005646985 Vs 14:58:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005656972 Vs 14:58:09 Magnet Current for MAIN, Imag = 99.9911 A Vtrans = 0.999868 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:58:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005648252 Vs 14:58:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005657207 Vs 14:58:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005652407 +- 0.000000329 Vs 14:58:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005652407 +- 0.000000329 Vs BL = 0.05652407 +- 0.00000329 Tm 14:58:27 Integrated Voltage Measurement... 14:58:28 Magnet Current for MAIN, Imag = 99.9909 A Vtrans = 0.999866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:58:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003769751 Vs 14:58:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003775764 Vs 14:58:49 Magnet Current for MAIN, Imag = 99.9906 A Vtrans = 0.999863 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:58:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003771918 Vs 14:59:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003776424 Vs 14:59:08 Magnet Current for MAIN, Imag = 99.9908 A Vtrans = 0.999864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:59:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003770680 Vs 14:59:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003776766 Vs 14:59:28 Magnet Current for MAIN, Imag = 99.9905 A Vtrans = 0.999862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:59:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003771299 Vs 14:59:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003778626 Vs 14:59:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003773904 +- 0.000000797 Vs 14:59:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003773904 +- 0.000000797 Vs BL = 0.03773904 +- 0.00000797 Tm 14:59:46 Integrated Voltage Measurement... 14:59:47 Magnet Current for MAIN, Imag = 99.9906 A Vtrans = 0.999863 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 14:59:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001896300 Vs 15:00:07 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001902049 Vs 15:00:08 Magnet Current for MAIN, Imag = 99.9904 A Vtrans = 0.999861 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:00:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001897028 Vs 15:00:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001901942 Vs 15:00:27 Magnet Current for MAIN, Imag = 99.9902 A Vtrans = 0.999859 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:00:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001898049 Vs 15:00:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001899009 Vs 15:00:47 Magnet Current for MAIN, Imag = 99.9908 A Vtrans = 0.999864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:00:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001897411 Vs 15:01:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001901184 Vs 15:01:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001899121 +- 0.000000359 Vs 15:01:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001899121 +- 0.000000359 Vs BL = 0.01899121 +- 0.00000359 Tm 15:01:05 Integrated Voltage Measurement... 15:01:06 Magnet Current for MAIN, Imag = 99.9909 A Vtrans = 0.999866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:01:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001851850 Vs 15:01:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001845829 Vs 15:01:27 Magnet Current for MAIN, Imag = 99.9908 A Vtrans = 0.999864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:01:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001853150 Vs 15:01:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001845487 Vs 15:01:46 Magnet Current for MAIN, Imag = 99.9906 A Vtrans = 0.999863 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:01:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001850636 Vs 15:02:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001846161 Vs 15:02:06 Magnet Current for MAIN, Imag = 99.9906 A Vtrans = 0.999863 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:02:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001850054 Vs 15:02:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001846126 Vs 15:02:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001848662 +- 0.000000464 Vs 15:02:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001848662 +- 0.000000464 Vs BL = -0.01848662 +- 0.00000464 Tm 15:02:25 Integrated Voltage Measurement... 15:02:26 Magnet Current for MAIN, Imag = 99.9910 A Vtrans = 0.999867 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:02:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003724610 Vs 15:02:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003720966 Vs 15:02:46 Magnet Current for MAIN, Imag = 99.9908 A Vtrans = 0.999864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:02:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003725728 Vs 15:03:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003720878 Vs 15:03:06 Magnet Current for MAIN, Imag = 99.9909 A Vtrans = 0.999866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:03:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003724467 Vs 15:03:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003719477 Vs 15:03:25 Magnet Current for MAIN, Imag = 99.9909 A Vtrans = 0.999866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:03:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003727663 Vs 15:03:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003720858 Vs 15:03:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003723081 +- 0.000000830 Vs 15:03:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003723081 +- 0.000000830 Vs BL = -0.03723081 +- 0.00000830 Tm 15:03:44 Integrated Voltage Measurement... 15:03:45 Magnet Current for MAIN, Imag = 99.9913 A Vtrans = 0.999869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:03:55 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005603092 Vs 15:04:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005597021 Vs 15:04:06 Magnet Current for MAIN, Imag = 99.9913 A Vtrans = 0.999869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:04:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005603817 Vs 15:04:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005597586 Vs 15:04:25 Magnet Current for MAIN, Imag = 99.9910 A Vtrans = 0.999867 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:04:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005603571 Vs 15:04:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005597762 Vs 15:04:45 Magnet Current for MAIN, Imag = 99.9909 A Vtrans = 0.999866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:04:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005602970 Vs 15:05:04 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.005598015 Vs 15:05:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.005600479 +- 0.000000256 Vs 15:05:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005600479 +- 0.000000256 Vs BL = -0.05600479 +- 0.00000256 Tm 15:05:07 Position moved: 0.000000 m 15:05:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00026 0.00000 1 -1.87501 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.05652 0.00000 0.05651 0.00002 -0.0200000 0.03774 0.00001 0.03776 -0.00002 -0.0100000 0.01899 0.00000 0.01901 -0.00001 0.0100000 -0.01849 0.00000 -0.01849 0.00001 0.0200000 -0.03723 0.00001 -0.03724 0.00001 0.0300000 -0.05600 0.00000 -0.05600 -0.00001 15:05:07 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.05652 0.00000 -0.0200 0.03774 0.00001 -0.0100 0.01899 0.00000 0.0100 -0.01849 0.00000 0.0200 -0.03723 0.00001 0.0300 -0.05600 0.00000 SL = -1.8750147 +- 0.0000959 Tm^2/m^n 15:05:07 Quadrupole Strength Calculation Check Slope = -1.875015 Tm/m, Inter = 0.000255 Tm, Sig_slope = 0.000324 Tm/m, Est_sig = 0.000017 Tm GL = -1.875015 +- 0.000324 T 15:05:07 Magnet Strength Measurement Harmonic Number = 2 SL = -1.8750147 +- 0.0000959 Tm^2/m^n 15:05:10 Position moved: 0.000000 m 15:05:10 Magnet system MAIN current ramping to 80.0000 A... 15:05:33 Magnet Current for MAIN, Imag = 80.0120 A Vtrans = 0.800077 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:05:34 Main (V) Voltage Measurement, V = 2.738615 V 15:05:35 Temperature Measurement, Probe Number = 0, T = 29.010000 C 15:05:39 Temperature Measurement, Probe Number = 1, T = 29.261000 C 15:05:40 Temperature Measurement, Probe Number = 2, T = 29.112000 C 15:05:41 Temperature Measurement, Probe Number = 3, T = 29.275000 C 15:05:42 Temperature Measurement, Probe Number = 4, T = 25.527000 C 15:05:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.362502 V 15:05:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362502 (V, A, ohm, ...), Measured Value = 28.923642 (C, atm, Hz, ...) 15:05:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.389393 V 15:05:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.389393 (V, A, ohm, ...), Measured Value = 29.297125 (C, atm, Hz, ...) 15:05:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.635603 V 15:05:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.635603 (V, A, ohm, ...), Measured Value = 122.670232 (C, atm, Hz, ...) 15:05:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097624 V 15:05:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097624 (V, A, ohm, ...), Measured Value = 7.321807 (C, atm, Hz, ...) 15:05:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003213 V 15:05:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003213 (V, A, ohm, ...), Measured Value = 3.213225 (C, atm, Hz, ...) 15:05:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.01 P1 = Main (V), Value = 2.74 P2 = Top Right Coil, Value = 29.01 P3 = Bottom Right Coil, Value = 29.26 P4 = Top Left Coil, Value = 29.11 P5 = Bottom Left Coil, Value = 29.27 P6 = Ambient, Value = 25.53 P7 = Supply Temp(C), Value = 28.92 P8 = Return Temp(C), Value = 29.30 P9 = Supply Pres(psi), Value = 122.67 P10 = Return Pres(psi), Value = 7.32 P11 = Flow Rate(gpm), Value = 3.21 15:05:48 Magnetic Field Measurement Measuring the magnet strength... 15:05:48 Integrated Voltage Measurement... 15:05:49 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:06:00 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004527887 Vs 15:06:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004533892 Vs 15:06:10 Magnet Current for MAIN, Imag = 80.0124 A Vtrans = 0.800080 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:06:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004529502 Vs 15:06:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004535413 Vs 15:06:29 Magnet Current for MAIN, Imag = 80.0127 A Vtrans = 0.800084 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:06:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004528425 Vs 15:06:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004536163 Vs 15:06:49 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:06:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004528308 Vs 15:07:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.004536793 Vs 15:07:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.004532048 +- 0.000000675 Vs 15:07:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004532048 +- 0.000000675 Vs BL = 0.04532048 +- 0.00000675 Tm 15:07:07 Integrated Voltage Measurement... 15:07:08 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:07:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003022212 Vs 15:07:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003029097 Vs 15:07:29 Magnet Current for MAIN, Imag = 80.0120 A Vtrans = 0.800077 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:07:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003022143 Vs 15:07:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003028669 Vs 15:07:48 Magnet Current for MAIN, Imag = 80.0120 A Vtrans = 0.800077 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:07:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003023886 Vs 15:08:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003027841 Vs 15:08:08 Magnet Current for MAIN, Imag = 80.0125 A Vtrans = 0.800082 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:08:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003021902 Vs 15:08:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003029272 Vs 15:08:26 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003025628 +- 0.000000164 Vs 15:08:26 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003025628 +- 0.000000164 Vs BL = 0.03025628 +- 0.00000164 Tm 15:08:26 Integrated Voltage Measurement... 15:08:27 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:08:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001518224 Vs 15:08:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001526331 Vs 15:08:48 Magnet Current for MAIN, Imag = 80.0121 A Vtrans = 0.800078 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:08:57 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001517454 Vs 15:09:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001526214 Vs 15:09:07 Magnet Current for MAIN, Imag = 80.0126 A Vtrans = 0.800083 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:09:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001519501 Vs 15:09:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001524424 Vs 15:09:27 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:09:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001520297 Vs 15:09:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001525032 Vs 15:09:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001522185 +- 0.000000321 Vs 15:09:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001522185 +- 0.000000321 Vs BL = 0.01522185 +- 0.00000321 Tm 15:09:45 Integrated Voltage Measurement... 15:09:46 Magnet Current for MAIN, Imag = 80.0117 A Vtrans = 0.800074 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:09:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001482765 Vs 15:10:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001481237 Vs 15:10:07 Magnet Current for MAIN, Imag = 80.0116 A Vtrans = 0.800073 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:10:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001485099 Vs 15:10:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001480375 Vs 15:10:27 Magnet Current for MAIN, Imag = 80.0121 A Vtrans = 0.800078 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:10:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001485714 Vs 15:10:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001478048 Vs 15:10:46 Magnet Current for MAIN, Imag = 80.0125 A Vtrans = 0.800082 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:10:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001488679 Vs 15:11:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001479253 Vs 15:11:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001482646 +- 0.000000829 Vs 15:11:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001482646 +- 0.000000829 Vs BL = -0.01482646 +- 0.00000829 Tm 15:11:05 Integrated Voltage Measurement... 15:11:06 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:11:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002990099 Vs 15:11:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002982399 Vs 15:11:27 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:11:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002990083 Vs 15:11:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002984285 Vs 15:11:46 Magnet Current for MAIN, Imag = 80.0121 A Vtrans = 0.800078 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:11:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002989654 Vs 15:12:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002982899 Vs 15:12:06 Magnet Current for MAIN, Imag = 80.0121 A Vtrans = 0.800078 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:12:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002989665 Vs 15:12:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002982267 Vs 15:12:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002986419 +- 0.000000458 Vs 15:12:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002986419 +- 0.000000458 Vs BL = -0.02986419 +- 0.00000458 Tm 15:12:24 Integrated Voltage Measurement... 15:12:25 Magnet Current for MAIN, Imag = 80.0125 A Vtrans = 0.800082 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:12:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004497344 Vs 15:12:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004484929 Vs 15:12:46 Magnet Current for MAIN, Imag = 80.0122 A Vtrans = 0.800079 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:12:55 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004496021 Vs 15:13:04 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004486876 Vs 15:13:05 Magnet Current for MAIN, Imag = 80.0124 A Vtrans = 0.800080 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:13:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004496198 Vs 15:13:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004486659 Vs 15:13:25 Magnet Current for MAIN, Imag = 80.0126 A Vtrans = 0.800083 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:13:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004493849 Vs 15:13:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.004487226 Vs 15:13:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.004491138 +- 0.000000368 Vs 15:13:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004491138 +- 0.000000368 Vs BL = -0.04491138 +- 0.00000368 Tm 15:13:48 Position moved: 0.000000 m 15:13:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00020 0.00000 1 -1.50352 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.04532 0.00001 0.04530 0.00002 -0.0200000 0.03026 0.00000 0.03027 -0.00001 -0.0100000 0.01522 0.00000 0.01523 -0.00001 0.0100000 -0.01483 0.00001 -0.01484 0.00001 0.0200000 -0.02986 0.00000 -0.02987 0.00001 0.0300000 -0.04491 0.00000 -0.04491 -0.00001 15:13:48 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.04532 0.00001 -0.0200 0.03026 0.00000 -0.0100 0.01522 0.00000 0.0100 -0.01483 0.00001 0.0200 -0.02986 0.00000 0.0300 -0.04491 0.00000 SL = -1.5035172 +- 0.0000949 Tm^2/m^n 15:13:48 Quadrupole Strength Calculation Check Slope = -1.503517 Tm/m, Inter = 0.000199 Tm, Sig_slope = 0.000258 Tm/m, Est_sig = 0.000014 Tm GL = -1.503517 +- 0.000258 T 15:13:48 Magnet Strength Measurement Harmonic Number = 2 SL = -1.5035172 +- 0.0000949 Tm^2/m^n 15:13:50 Position moved: 0.000000 m 15:13:50 Magnet system MAIN current ramping to 60.0000 A... 15:14:14 Magnet Current for MAIN, Imag = 59.9426 A Vtrans = 0.599383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:14:15 Main (V) Voltage Measurement, V = 2.051146 V 15:14:16 Temperature Measurement, Probe Number = 0, T = 28.954000 C 15:14:19 Temperature Measurement, Probe Number = 1, T = 29.190000 C 15:14:20 Temperature Measurement, Probe Number = 2, T = 29.052000 C 15:14:21 Temperature Measurement, Probe Number = 3, T = 29.202000 C 15:14:22 Temperature Measurement, Probe Number = 4, T = 25.662000 C 15:14:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.361939 V 15:14:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361939 (V, A, ohm, ...), Measured Value = 28.915821 (C, atm, Hz, ...) 15:14:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.381404 V 15:14:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.381404 (V, A, ohm, ...), Measured Value = 29.186171 (C, atm, Hz, ...) 15:14:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655110 V 15:14:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655110 (V, A, ohm, ...), Measured Value = 124.133273 (C, atm, Hz, ...) 15:14:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097774 V 15:14:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097774 (V, A, ohm, ...), Measured Value = 7.333058 (C, atm, Hz, ...) 15:14:29 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003221 V 15:14:29 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003221 (V, A, ohm, ...), Measured Value = 3.220830 (C, atm, Hz, ...) 15:14:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.94 P1 = Main (V), Value = 2.05 P2 = Top Right Coil, Value = 28.95 P3 = Bottom Right Coil, Value = 29.19 P4 = Top Left Coil, Value = 29.05 P5 = Bottom Left Coil, Value = 29.20 P6 = Ambient, Value = 25.66 P7 = Supply Temp(C), Value = 28.92 P8 = Return Temp(C), Value = 29.19 P9 = Supply Pres(psi), Value = 124.13 P10 = Return Pres(psi), Value = 7.33 P11 = Flow Rate(gpm), Value = 3.22 15:14:29 Magnetic Field Measurement Measuring the magnet strength... 15:14:29 Integrated Voltage Measurement... 15:14:30 Magnet Current for MAIN, Imag = 59.9418 A Vtrans = 0.599375 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:14:40 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003403506 Vs 15:14:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003408648 Vs 15:14:50 Magnet Current for MAIN, Imag = 59.9422 A Vtrans = 0.599379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:14:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003402178 Vs 15:15:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003408454 Vs 15:15:10 Magnet Current for MAIN, Imag = 59.9421 A Vtrans = 0.599378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:15:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003403628 Vs 15:15:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003407560 Vs 15:15:29 Magnet Current for MAIN, Imag = 59.9426 A Vtrans = 0.599383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:15:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003404035 Vs 15:15:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003408643 Vs 15:15:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003405831 +- 0.000000400 Vs 15:15:48 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003405831 +- 0.000000400 Vs BL = 0.03405831 +- 0.00000400 Tm 15:15:48 Integrated Voltage Measurement... 15:15:49 Magnet Current for MAIN, Imag = 59.9426 A Vtrans = 0.599383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:15:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002270959 Vs 15:16:08 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002278020 Vs 15:16:09 Magnet Current for MAIN, Imag = 59.9425 A Vtrans = 0.599382 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:16:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002269385 Vs 15:16:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002276645 Vs 15:16:29 Magnet Current for MAIN, Imag = 59.9427 A Vtrans = 0.599384 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:16:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002270788 Vs 15:16:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002275841 Vs 15:16:48 Magnet Current for MAIN, Imag = 59.9421 A Vtrans = 0.599378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:16:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002270561 Vs 15:17:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002275836 Vs 15:17:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002273504 +- 0.000000579 Vs 15:17:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002273504 +- 0.000000579 Vs BL = 0.02273504 +- 0.00000579 Tm 15:17:07 Integrated Voltage Measurement... 15:17:08 Magnet Current for MAIN, Imag = 59.9422 A Vtrans = 0.599379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:17:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001143008 Vs 15:17:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001145738 Vs 15:17:29 Magnet Current for MAIN, Imag = 59.9421 A Vtrans = 0.599378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:17:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001140859 Vs 15:17:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001147363 Vs 15:17:48 Magnet Current for MAIN, Imag = 59.9422 A Vtrans = 0.599379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:17:57 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001139727 Vs 15:18:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001149850 Vs 15:18:07 Magnet Current for MAIN, Imag = 59.9422 A Vtrans = 0.599379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:18:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001137196 Vs 15:18:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001147598 Vs 15:18:26 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001143918 +- 0.000000910 Vs 15:18:26 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001143918 +- 0.000000910 Vs BL = 0.01143918 +- 0.00000910 Tm 15:18:26 Integrated Voltage Measurement... 15:18:27 Magnet Current for MAIN, Imag = 59.9423 A Vtrans = 0.599380 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:18:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001118660 Vs 15:18:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001112796 Vs 15:18:48 Magnet Current for MAIN, Imag = 59.9426 A Vtrans = 0.599383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:18:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001117217 Vs 15:19:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001114933 Vs 15:19:07 Magnet Current for MAIN, Imag = 59.9422 A Vtrans = 0.599379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:19:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001118204 Vs 15:19:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001112331 Vs 15:19:27 Magnet Current for MAIN, Imag = 59.9425 A Vtrans = 0.599382 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:19:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001118948 Vs 15:19:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001112429 Vs 15:19:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001115690 +- 0.000000286 Vs 15:19:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001115690 +- 0.000000286 Vs BL = -0.01115690 +- 0.00000286 Tm 15:19:45 Integrated Voltage Measurement... 15:19:46 Magnet Current for MAIN, Imag = 59.9427 A Vtrans = 0.599384 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:19:57 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002250820 Vs 15:20:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002240539 Vs 15:20:07 Magnet Current for MAIN, Imag = 59.9427 A Vtrans = 0.599384 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:20:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002249088 Vs 15:20:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002242462 Vs 15:20:27 Magnet Current for MAIN, Imag = 59.9429 A Vtrans = 0.599385 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:20:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002249237 Vs 15:20:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002241652 Vs 15:20:46 Magnet Current for MAIN, Imag = 59.9427 A Vtrans = 0.599384 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:20:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002248817 Vs 15:21:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002241947 Vs 15:21:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002245570 +- 0.000000162 Vs 15:21:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002245570 +- 0.000000162 Vs BL = -0.02245570 +- 0.00000162 Tm 15:21:05 Integrated Voltage Measurement... 15:21:06 Magnet Current for MAIN, Imag = 59.9427 A Vtrans = 0.599384 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:21:16 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003380531 Vs 15:21:25 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003372604 Vs 15:21:26 Magnet Current for MAIN, Imag = 59.9429 A Vtrans = 0.599385 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:21:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003380361 Vs 15:21:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003373014 Vs 15:21:46 Magnet Current for MAIN, Imag = 59.9421 A Vtrans = 0.599378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:21:55 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003380670 Vs 15:22:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003373063 Vs 15:22:06 Magnet Current for MAIN, Imag = 59.9421 A Vtrans = 0.599378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:22:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003380689 Vs 15:22:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003372503 Vs 15:22:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003376679 +- 0.000000117 Vs 15:22:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003376679 +- 0.000000117 Vs BL = -0.03376679 +- 0.00000117 Tm 15:22:28 Position moved: 0.000000 m 15:22:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00014 0.00000 1 -1.13019 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.03406 0.00000 0.03405 0.00001 -0.0200000 0.02274 0.00001 0.02275 -0.00001 -0.0100000 0.01144 0.00001 0.01144 -0.00000 0.0100000 -0.01116 0.00000 -0.01116 0.00000 0.0200000 -0.02246 0.00000 -0.02246 0.00001 0.0300000 -0.03377 0.00000 -0.03376 -0.00000 15:22:28 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.03406 0.00000 -0.0200 0.02274 0.00001 -0.0100 0.01144 0.00001 0.0100 -0.01116 0.00000 0.0200 -0.02246 0.00000 0.0300 -0.03377 0.00000 SL = -1.1301889 +- 0.0000707 Tm^2/m^n 15:22:28 Quadrupole Strength Calculation Check Slope = -1.130189 Tm/m, Inter = 0.000142 Tm, Sig_slope = 0.000165 Tm/m, Est_sig = 0.000009 Tm GL = -1.130189 +- 0.000165 T 15:22:28 Magnet Strength Measurement Harmonic Number = 2 SL = -1.1301889 +- 0.0000707 Tm^2/m^n 15:22:31 Position moved: 0.000000 m 15:22:31 Magnet system MAIN current ramping to 40.0000 A... 15:22:54 Magnet Current for MAIN, Imag = 39.9637 A Vtrans = 0.399594 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:22:55 Main (V) Voltage Measurement, V = 1.367317 V 15:22:56 Temperature Measurement, Probe Number = 0, T = 28.893000 C 15:23:00 Temperature Measurement, Probe Number = 1, T = 29.142000 C 15:23:01 Temperature Measurement, Probe Number = 2, T = 29.024000 C 15:23:02 Temperature Measurement, Probe Number = 3, T = 29.147000 C 15:23:02 Temperature Measurement, Probe Number = 4, T = 25.723000 C 15:23:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.362573 V 15:23:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362573 (V, A, ohm, ...), Measured Value = 28.924631 (C, atm, Hz, ...) 15:23:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.374818 V 15:23:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.374818 (V, A, ohm, ...), Measured Value = 29.094689 (C, atm, Hz, ...) 15:23:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663268 V 15:23:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663268 (V, A, ohm, ...), Measured Value = 124.745100 (C, atm, Hz, ...) 15:23:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098477 V 15:23:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098477 (V, A, ohm, ...), Measured Value = 7.385775 (C, atm, Hz, ...) 15:23:09 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003253 V 15:23:09 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003253 (V, A, ohm, ...), Measured Value = 3.252524 (C, atm, Hz, ...) 15:23:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = Main (V), Value = 1.37 P2 = Top Right Coil, Value = 28.89 P3 = Bottom Right Coil, Value = 29.14 P4 = Top Left Coil, Value = 29.02 P5 = Bottom Left Coil, Value = 29.15 P6 = Ambient, Value = 25.72 P7 = Supply Temp(C), Value = 28.92 P8 = Return Temp(C), Value = 29.09 P9 = Supply Pres(psi), Value = 124.75 P10 = Return Pres(psi), Value = 7.39 P11 = Flow Rate(gpm), Value = 3.25 15:23:09 Magnetic Field Measurement Measuring the magnet strength... 15:23:09 Integrated Voltage Measurement... 15:23:10 Magnet Current for MAIN, Imag = 39.9637 A Vtrans = 0.399594 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:23:20 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002283398 Vs 15:23:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002286431 Vs 15:23:31 Magnet Current for MAIN, Imag = 39.9636 A Vtrans = 0.399593 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:23:40 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002282700 Vs 15:23:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002288315 Vs 15:23:50 Magnet Current for MAIN, Imag = 39.9640 A Vtrans = 0.399597 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:24:00 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002282232 Vs 15:24:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002288223 Vs 15:24:10 Magnet Current for MAIN, Imag = 39.9636 A Vtrans = 0.399593 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:24:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002281627 Vs 15:24:29 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.002287932 Vs 15:24:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.002285107 +- 0.000000282 Vs 15:24:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002285107 +- 0.000000282 Vs BL = 0.02285107 +- 0.00000282 Tm 15:24:29 Integrated Voltage Measurement... 15:24:30 Magnet Current for MAIN, Imag = 39.9635 A Vtrans = 0.399591 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:24:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001519569 Vs 15:24:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001531128 Vs 15:24:50 Magnet Current for MAIN, Imag = 39.9632 A Vtrans = 0.399589 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:25:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001518142 Vs 15:25:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001529715 Vs 15:25:10 Magnet Current for MAIN, Imag = 39.9640 A Vtrans = 0.399597 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:25:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001520310 Vs 15:25:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001529928 Vs 15:25:30 Magnet Current for MAIN, Imag = 39.9633 A Vtrans = 0.399590 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:25:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001520442 Vs 15:25:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001528619 Vs 15:25:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001524732 +- 0.000000551 Vs 15:25:48 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001524732 +- 0.000000551 Vs BL = 0.01524732 +- 0.00000551 Tm 15:25:48 Integrated Voltage Measurement... 15:25:49 Magnet Current for MAIN, Imag = 39.9635 A Vtrans = 0.399591 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:25:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000763627 Vs 15:26:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000768172 Vs 15:26:10 Magnet Current for MAIN, Imag = 39.9635 A Vtrans = 0.399591 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:26:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000764824 Vs 15:26:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000768350 Vs 15:26:29 Magnet Current for MAIN, Imag = 39.9637 A Vtrans = 0.399594 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:26:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000764938 Vs 15:26:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000769143 Vs 15:26:49 Magnet Current for MAIN, Imag = 39.9632 A Vtrans = 0.399589 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:26:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000764458 Vs 15:27:07 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000768897 Vs 15:27:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000766551 +- 0.000000412 Vs 15:27:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000766551 +- 0.000000412 Vs BL = 0.00766551 +- 0.00000412 Tm 15:27:07 Integrated Voltage Measurement... 15:27:08 Magnet Current for MAIN, Imag = 39.9633 A Vtrans = 0.399590 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:27:19 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000751650 Vs 15:27:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000748393 Vs 15:27:29 Magnet Current for MAIN, Imag = 39.9635 A Vtrans = 0.399591 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:27:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000750764 Vs 15:27:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000747872 Vs 15:27:49 Magnet Current for MAIN, Imag = 39.9636 A Vtrans = 0.399593 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:27:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000751887 Vs 15:28:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000746977 Vs 15:28:08 Magnet Current for MAIN, Imag = 39.9633 A Vtrans = 0.399590 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:28:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000752287 Vs 15:28:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000746899 Vs 15:28:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000749591 +- 0.000000267 Vs 15:28:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000749591 +- 0.000000267 Vs BL = -0.00749591 +- 0.00000267 Tm 15:28:27 Integrated Voltage Measurement... 15:28:28 Magnet Current for MAIN, Imag = 39.9633 A Vtrans = 0.399590 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:28:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001511077 Vs 15:28:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001503824 Vs 15:28:48 Magnet Current for MAIN, Imag = 39.9640 A Vtrans = 0.399597 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:28:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001513573 Vs 15:29:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001502800 Vs 15:29:08 Magnet Current for MAIN, Imag = 39.9637 A Vtrans = 0.399594 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:29:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001513288 Vs 15:29:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001504056 Vs 15:29:27 Magnet Current for MAIN, Imag = 39.9633 A Vtrans = 0.399590 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:29:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001512797 Vs 15:29:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001503843 Vs 15:29:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001508157 +- 0.000000445 Vs 15:29:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001508157 +- 0.000000445 Vs BL = -0.01508157 +- 0.00000445 Tm 15:29:46 Integrated Voltage Measurement... 15:29:47 Magnet Current for MAIN, Imag = 39.9633 A Vtrans = 0.399590 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:29:57 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002270734 Vs 15:30:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002265322 Vs 15:30:07 Magnet Current for MAIN, Imag = 39.9638 A Vtrans = 0.399595 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:30:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002270045 Vs 15:30:26 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002265540 Vs 15:30:27 Magnet Current for MAIN, Imag = 39.9635 A Vtrans = 0.399591 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:30:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002269036 Vs 15:30:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002265676 Vs 15:30:46 Magnet Current for MAIN, Imag = 39.9632 A Vtrans = 0.399589 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:30:56 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002268914 Vs 15:31:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.002266774 Vs 15:31:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.002267755 +- 0.000000247 Vs 15:31:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002267755 +- 0.000000247 Vs BL = -0.02267755 +- 0.00000247 Tm 15:31:09 Position moved: 0.000000 m 15:31:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00008 0.00000 1 -0.75859 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.02285 0.00000 0.02284 0.00001 -0.0200000 0.01525 0.00001 0.01526 -0.00001 -0.0100000 0.00767 0.00000 0.00767 -0.00001 0.0100000 -0.00750 0.00000 -0.00750 0.00001 0.0200000 -0.01508 0.00000 -0.01509 0.00001 0.0300000 -0.02268 0.00000 -0.02267 -0.00000 15:31:09 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.02285 0.00000 -0.0200 0.01525 0.00001 -0.0100 0.00767 0.00000 0.0100 -0.00750 0.00000 0.0200 -0.01508 0.00000 0.0300 -0.02268 0.00000 SL = -0.7585896 +- 0.0000670 Tm^2/m^n 15:31:09 Quadrupole Strength Calculation Check Slope = -0.758590 Tm/m, Inter = 0.000085 Tm, Sig_slope = 0.000154 Tm/m, Est_sig = 0.000008 Tm GL = -0.758590 +- 0.000154 T 15:31:09 Magnet Strength Measurement Harmonic Number = 2 SL = -0.7585896 +- 0.0000670 Tm^2/m^n 15:31:12 Position moved: 0.000000 m 15:31:12 Magnet system MAIN current ramping to 20.0000 A... 15:31:35 Magnet Current for MAIN, Imag = 19.9786 A Vtrans = 0.199743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:31:36 Main (V) Voltage Measurement, V = 0.683537 V 15:31:37 Temperature Measurement, Probe Number = 0, T = 28.870000 C 15:31:41 Temperature Measurement, Probe Number = 1, T = 29.119000 C 15:31:42 Temperature Measurement, Probe Number = 2, T = 29.017000 C 15:31:42 Temperature Measurement, Probe Number = 3, T = 29.110000 C 15:31:43 Temperature Measurement, Probe Number = 4, T = 25.826000 C 15:31:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.363349 V 15:31:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.363349 (V, A, ohm, ...), Measured Value = 28.935399 (C, atm, Hz, ...) 15:31:45 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370410 V 15:31:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370410 (V, A, ohm, ...), Measured Value = 29.033465 (C, atm, Hz, ...) 15:31:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659270 V 15:31:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659270 (V, A, ohm, ...), Measured Value = 124.445287 (C, atm, Hz, ...) 15:31:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098101 V 15:31:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098101 (V, A, ohm, ...), Measured Value = 7.357560 (C, atm, Hz, ...) 15:31:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003232 V 15:31:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003232 (V, A, ohm, ...), Measured Value = 3.231546 (C, atm, Hz, ...) 15:31:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = Main (V), Value = 0.68 P2 = Top Right Coil, Value = 28.87 P3 = Bottom Right Coil, Value = 29.12 P4 = Top Left Coil, Value = 29.02 P5 = Bottom Left Coil, Value = 29.11 P6 = Ambient, Value = 25.83 P7 = Supply Temp(C), Value = 28.94 P8 = Return Temp(C), Value = 29.03 P9 = Supply Pres(psi), Value = 124.45 P10 = Return Pres(psi), Value = 7.36 P11 = Flow Rate(gpm), Value = 3.23 15:31:50 Magnetic Field Measurement Measuring the magnet strength... 15:31:50 Integrated Voltage Measurement... 15:31:51 Magnet Current for MAIN, Imag = 19.9790 A Vtrans = 0.199747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:32:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001161146 Vs 15:32:11 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001167585 Vs 15:32:12 Magnet Current for MAIN, Imag = 19.9791 A Vtrans = 0.199748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:32:21 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001160102 Vs 15:32:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001166854 Vs 15:32:31 Magnet Current for MAIN, Imag = 19.9789 A Vtrans = 0.199745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:32:40 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001160428 Vs 15:32:50 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001167444 Vs 15:32:51 Magnet Current for MAIN, Imag = 19.9791 A Vtrans = 0.199748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:33:00 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001160108 Vs 15:33:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.001167223 Vs 15:33:09 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.001163861 +- 0.000000334 Vs 15:33:09 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001163861 +- 0.000000334 Vs BL = 0.01163861 +- 0.00000334 Tm 15:33:09 Integrated Voltage Measurement... 15:33:10 Magnet Current for MAIN, Imag = 19.9783 A Vtrans = 0.199740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:33:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000773257 Vs 15:33:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000778680 Vs 15:33:31 Magnet Current for MAIN, Imag = 19.9786 A Vtrans = 0.199743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:33:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000772442 Vs 15:33:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000778856 Vs 15:33:51 Magnet Current for MAIN, Imag = 19.9786 A Vtrans = 0.199743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:34:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000773386 Vs 15:34:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000779283 Vs 15:34:10 Magnet Current for MAIN, Imag = 19.9791 A Vtrans = 0.199748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:34:20 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000773525 Vs 15:34:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000777769 Vs 15:34:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000775900 +- 0.000000283 Vs 15:34:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000775900 +- 0.000000283 Vs BL = 0.00775900 +- 0.00000283 Tm 15:34:29 Integrated Voltage Measurement... 15:34:30 Magnet Current for MAIN, Imag = 19.9789 A Vtrans = 0.199745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:34:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000387323 Vs 15:34:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000392218 Vs 15:34:51 Magnet Current for MAIN, Imag = 19.9789 A Vtrans = 0.199745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:35:00 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000387801 Vs 15:35:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000391917 Vs 15:35:10 Magnet Current for MAIN, Imag = 19.9786 A Vtrans = 0.199743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:35:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000386966 Vs 15:35:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000392320 Vs 15:35:30 Magnet Current for MAIN, Imag = 19.9787 A Vtrans = 0.199744 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:35:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000386911 Vs 15:35:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000391703 Vs 15:35:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000389645 +- 0.000000210 Vs 15:35:48 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000389645 +- 0.000000210 Vs BL = 0.00389645 +- 0.00000210 Tm 15:35:48 Integrated Voltage Measurement... 15:35:49 Magnet Current for MAIN, Imag = 19.9789 A Vtrans = 0.199745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:36:00 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000387688 Vs 15:36:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000379204 Vs 15:36:10 Magnet Current for MAIN, Imag = 19.9789 A Vtrans = 0.199745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:36:19 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000387531 Vs 15:36:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000379841 Vs 15:36:29 Magnet Current for MAIN, Imag = 19.9790 A Vtrans = 0.199747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:36:39 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000387434 Vs 15:36:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000380032 Vs 15:36:49 Magnet Current for MAIN, Imag = 19.9791 A Vtrans = 0.199748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:36:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000387869 Vs 15:37:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000378747 Vs 15:37:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000383543 +- 0.000000174 Vs 15:37:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000383543 +- 0.000000174 Vs BL = -0.00383543 +- 0.00000174 Tm 15:37:07 Integrated Voltage Measurement... 15:37:08 Magnet Current for MAIN, Imag = 19.9790 A Vtrans = 0.199747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:37:18 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000775916 Vs 15:37:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000767150 Vs 15:37:29 Magnet Current for MAIN, Imag = 19.9785 A Vtrans = 0.199742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:37:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000773308 Vs 15:37:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000768303 Vs 15:37:48 Magnet Current for MAIN, Imag = 19.9790 A Vtrans = 0.199747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:37:57 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000772565 Vs 15:38:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000767963 Vs 15:38:08 Magnet Current for MAIN, Imag = 19.9785 A Vtrans = 0.199742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:38:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000772243 Vs 15:38:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000768296 Vs 15:38:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000770718 +- 0.000000519 Vs 15:38:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000770718 +- 0.000000519 Vs BL = -0.00770718 +- 0.00000519 Tm 15:38:26 Integrated Voltage Measurement... 15:38:27 Magnet Current for MAIN, Imag = 19.9790 A Vtrans = 0.199747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:38:38 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001159023 Vs 15:38:47 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001155144 Vs 15:38:48 Magnet Current for MAIN, Imag = 19.9785 A Vtrans = 0.199742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:38:57 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001159402 Vs 15:39:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001155910 Vs 15:39:07 Magnet Current for MAIN, Imag = 19.9789 A Vtrans = 0.199745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:39:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001159845 Vs 15:39:26 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001155708 Vs 15:39:27 Magnet Current for MAIN, Imag = 19.9790 A Vtrans = 0.199747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:39:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001160251 Vs 15:39:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.001154136 Vs 15:39:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.001157428 +- 0.000000295 Vs 15:39:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001157428 +- 0.000000295 Vs BL = -0.01157428 +- 0.00000295 Tm 15:39:49 Position moved: 0.000000 m 15:39:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00003 0.00000 1 -0.38680 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.01164 0.00000 0.01163 0.00001 -0.0200000 0.00776 0.00000 0.00777 -0.00001 -0.0100000 0.00390 0.00000 0.00390 -0.00000 0.0100000 -0.00384 0.00000 -0.00384 0.00000 0.0200000 -0.00771 0.00001 -0.00771 -0.00000 0.0300000 -0.01157 0.00000 -0.01157 0.00000 15:39:49 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.01164 0.00000 -0.0200 0.00776 0.00000 -0.0100 0.00390 0.00000 0.0100 -0.00384 0.00000 0.0200 -0.00771 0.00001 0.0300 -0.01157 0.00000 SL = -0.3867961 +- 0.0000645 Tm^2/m^n 15:39:49 Quadrupole Strength Calculation Check Slope = -0.386796 Tm/m, Inter = 0.000030 Tm, Sig_slope = 0.000084 Tm/m, Est_sig = 0.000004 Tm GL = -0.386796 +- 0.000084 T 15:39:49 Magnet Strength Measurement Harmonic Number = 2 SL = -0.3867961 +- 0.0000645 Tm^2/m^n 15:39:52 Position moved: 0.000000 m 15:39:52 Magnet system MAIN current ramping to 0.0000 A... 15:40:16 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:40:16 Main (V) Voltage Measurement, V = 0.000231 V 15:40:17 Temperature Measurement, Probe Number = 0, T = 28.861000 C 15:40:21 Temperature Measurement, Probe Number = 1, T = 29.108000 C 15:40:22 Temperature Measurement, Probe Number = 2, T = 29.009000 C 15:40:23 Temperature Measurement, Probe Number = 3, T = 29.094000 C 15:40:24 Temperature Measurement, Probe Number = 4, T = 25.961000 C 15:40:24 Sensor Voltage Measurement, Sensor Number = 0, V = 2.362920 V 15:40:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362920 (V, A, ohm, ...), Measured Value = 28.929450 (C, atm, Hz, ...) 15:40:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367918 V 15:40:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367918 (V, A, ohm, ...), Measured Value = 28.998864 (C, atm, Hz, ...) 15:40:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651628 V 15:40:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651628 (V, A, ohm, ...), Measured Value = 123.872062 (C, atm, Hz, ...) 15:40:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098054 V 15:40:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098054 (V, A, ohm, ...), Measured Value = 7.354027 (C, atm, Hz, ...) 15:40:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.003231 V 15:40:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.003231 (V, A, ohm, ...), Measured Value = 3.231020 (C, atm, Hz, ...) 15:40:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = Main (V), Value = 0.00 P2 = Top Right Coil, Value = 28.86 P3 = Bottom Right Coil, Value = 29.11 P4 = Top Left Coil, Value = 29.01 P5 = Bottom Left Coil, Value = 29.09 P6 = Ambient, Value = 25.96 P7 = Supply Temp(C), Value = 28.93 P8 = Return Temp(C), Value = 29.00 P9 = Supply Pres(psi), Value = 123.87 P10 = Return Pres(psi), Value = 7.35 P11 = Flow Rate(gpm), Value = 3.23 15:40:30 Magnetic Field Measurement Measuring the magnet strength... 15:40:30 Integrated Voltage Measurement... 15:40:31 Magnet Current for MAIN, Imag = 0.0077 A Vtrans = 0.000034 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:40:42 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000042160 Vs 15:40:51 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000043633 Vs 15:40:52 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:41:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000041349 Vs 15:41:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000043812 Vs 15:41:12 Magnet Current for MAIN, Imag = 0.0077 A Vtrans = 0.000034 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:41:21 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000042030 Vs 15:41:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000044983 Vs 15:41:31 Magnet Current for MAIN, Imag = 0.0076 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:41:40 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000040250 Vs 15:41:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.000046192 Vs 15:41:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.000043051 +- 0.000000347 Vs 15:41:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000043051 +- 0.000000347 Vs BL = 0.00043051 +- 0.00000347 Tm 15:41:49 Integrated Voltage Measurement... 15:41:50 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:42:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000024859 Vs 15:42:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000031090 Vs 15:42:11 Magnet Current for MAIN, Imag = 0.0080 A Vtrans = 0.000037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:42:20 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000023722 Vs 15:42:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000030962 Vs 15:42:31 Magnet Current for MAIN, Imag = 0.0081 A Vtrans = 0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:42:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000023956 Vs 15:42:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000031342 Vs 15:42:50 Magnet Current for MAIN, Imag = 0.0077 A Vtrans = 0.000034 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:43:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000024479 Vs 15:43:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000030359 Vs 15:43:09 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000027596 +- 0.000000246 Vs 15:43:09 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000027596 +- 0.000000246 Vs BL = 0.00027596 +- 0.00000246 Tm 15:43:09 Integrated Voltage Measurement... 15:43:10 Magnet Current for MAIN, Imag = 0.0076 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:43:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000009192 Vs 15:43:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000016401 Vs 15:43:30 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:43:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000008225 Vs 15:43:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000016894 Vs 15:43:50 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:43:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000009245 Vs 15:44:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000017377 Vs 15:44:10 Magnet Current for MAIN, Imag = 0.0080 A Vtrans = 0.000037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:44:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000008035 Vs 15:44:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000018107 Vs 15:44:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000012934 +- 0.000000283 Vs 15:44:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000012934 +- 0.000000283 Vs BL = 0.00012934 +- 0.00000283 Tm 15:44:28 Integrated Voltage Measurement... 15:44:29 Magnet Current for MAIN, Imag = 0.0080 A Vtrans = 0.000037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:44:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000022366 Vs 15:44:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000012543 Vs 15:44:50 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:44:59 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000021890 Vs 15:45:08 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000012681 Vs 15:45:09 Magnet Current for MAIN, Imag = 0.0077 A Vtrans = 0.000034 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:45:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000021981 Vs 15:45:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000014137 Vs 15:45:29 Magnet Current for MAIN, Imag = 0.0077 A Vtrans = 0.000034 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:45:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000020385 Vs 15:45:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000015013 Vs 15:45:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000017624 +- 0.000000291 Vs 15:45:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000017624 +- 0.000000291 Vs BL = -0.00017624 +- 0.00000291 Tm 15:45:47 Integrated Voltage Measurement... 15:45:48 Magnet Current for MAIN, Imag = 0.0077 A Vtrans = 0.000034 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:45:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000035262 Vs 15:46:08 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000031610 Vs 15:46:09 Magnet Current for MAIN, Imag = 0.0076 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:46:18 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000035665 Vs 15:46:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000030689 Vs 15:46:29 Magnet Current for MAIN, Imag = 0.0076 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:46:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000035816 Vs 15:46:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000029703 Vs 15:46:48 Magnet Current for MAIN, Imag = 0.0072 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:46:57 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000036329 Vs 15:47:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000029700 Vs 15:47:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000033097 +- 0.000000246 Vs 15:47:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000033097 +- 0.000000246 Vs BL = -0.00033097 +- 0.00000246 Tm 15:47:07 Integrated Voltage Measurement... 15:47:08 Magnet Current for MAIN, Imag = 0.0080 A Vtrans = 0.000037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:47:18 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000050300 Vs 15:47:27 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000045616 Vs 15:47:28 Magnet Current for MAIN, Imag = 0.0076 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:47:38 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000049803 Vs 15:47:47 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000046240 Vs 15:47:48 Magnet Current for MAIN, Imag = 0.0076 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:47:57 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000049760 Vs 15:48:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000044923 Vs 15:48:07 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004320 A 15:48:16 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000051009 Vs 15:48:26 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.000043901 Vs 15:48:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.000047694 +- 0.000000299 Vs 15:48:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000047694 +- 0.000000299 Vs BL = -0.00047694 +- 0.00000299 Tm 15:48:29 Position moved: 0.000000 m 15:48:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00002 0.00000 1 -0.01515 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 0.00043 0.00000 0.00043 0.00000 -0.0200000 0.00028 0.00000 0.00028 -0.00000 -0.0100000 0.00013 0.00000 0.00013 0.00000 0.0100000 -0.00018 0.00000 -0.00018 -0.00000 0.0200000 -0.00033 0.00000 -0.00033 -0.00000 0.0300000 -0.00048 0.00000 -0.00048 0.00000 15:48:29 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 6 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.00043 0.00000 -0.0200 0.00028 0.00000 -0.0100 0.00013 0.00000 0.0100 -0.00018 0.00000 0.0200 -0.00033 0.00000 0.0300 -0.00048 0.00000 SL = -0.0151493 +- 0.0000569 Tm^2/m^n 15:48:29 Quadrupole Strength Calculation Check Slope = -0.015149 Tm/m, Inter = -0.000025 Tm, Sig_slope = 0.000050 Tm/m, Est_sig = 0.000003 Tm GL = -0.015149 +- 0.000050 T 15:48:29 Magnet Strength Measurement Harmonic Number = 2 SL = -0.0151493 +- 0.0000569 Tm^2/m^n 15:48:32 Position moved: 0.000000 m 15:48:35 Position moved: 0.000000 m 15:48:38 Magnet system MAIN current ramping to 0.0000 A...