SLAC Magnetic Measurements Date: 05-21-2025 Time: 08:19:10 Project: A-line Magnet Type: Quad Magnet Name: Q38 Serial Number: 10 Run Number: 2 Measurement Device: 10wire Operator: sda Comment: Test Standardization for MAIN: 1 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for MAIN (A): 160.00 Integrated Quadrupole Gradient Distance the wire was to be moved = 0.010000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 MAIN +/- sigma GL sigGL GL/I sigGL/I (A) (A) (T) (T) (T/A) (T/A) ------------+---------- -------------+------------ -------------+------------- 160.0111 0.0008 2.974863 0.000037 0.018592 0.000000