Sextupole
Magnet Checks |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Date: |
|
Magnet: |
|
|
|
Operator(s): |
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

|
|
Magnetic
Fiducial Coordinates: (inches) |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fiducial |
Z |
X |
Y |
|
|
|
|
|
|
|
|
-4.3115 |
4.2203 |
15.5105 |
|
|
|
|
|
|
|
|
|
4.3306 |
4.2022 |
15.5006 |
|
|
|
|
|
|
|
|
|
-4.3810 |
-10.4585 |
12.5644 |
|
|
Offset: |
|
|
|
|
|
|
3.5307 |
-10.4785 |
12.5519 |
|
|
0.0000 |
inches |
|
|
|
|
|
-4.5603 |
-15.0652 |
0.0650 |
|
|
|
|
|
|
|
|
|
4.5174 |
-15.0615 |
0.0475 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Description: |
|
|
|
|
|
|
|
|
|
|
|
Fiducial
values based on the measured mechanical center line. |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
Sextupole
Mechanical Centerline Checks:
|
Mandrel Check (4 Positions): |
X (in) |
Y (in) |
|
0.0000 |
-0.0006 |
|
|
-0.0008 |
-0.0015 |
|
|
0.0021 |
-0.0020 |
|
|
0.0019 |
-0.0010 |
|
|
0.0020 |
-0.0007 |
|
|
0.0005 |
-0.0012 |

|
Mandrel Check (Position 1): |
X (in) |
Y (in) |
|
0.0016 |
-0.0005 |
|
|
0.0014 |
0.0003 |
|
|
0.0026 |
-0.0016 |
|
|
NA |
NA |
|
|
NA |
NA |

|
|
|
|
Gap Measurements: |
|
|
Upstream (in) |
Downstream (in) |
Approval ________________________
|
|
|
Sextupole Magnet Fiducialization Traveller |
|
Approval must be obtained before removing the magnet from the test stand. |
|
Magnetic Measurements Approval by – Jack Tanabe or Tony King. |
|
IHEP Magnetic Measurements Operator: ____________ Date:_____________ |
|
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
|
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
|
SLAC Magnetic Measurements Operator: ____________ Date:_____________ |
|
Measured Magnetic Center Offset Dx =__________ mm Dy =___________ mm |
|
Measured at: Integrated Field: ____________ T-m @ Current_____________ Amps |
|
Fiducialization: |

|
Fiducial – Measured Coordinates |
z |
x |
y |
|
(in) |
(in) |
(in) |
|
|
-4.3115 |
4.2203 |
15.5105 |
|
|
4.3306 |
4.2022 |
15.5006 |
|
|
-4.3810 |
-10.4585 |
12.5644 |
|
|
3.5307 |
-10.4785 |
12.5519 |
|
|
-4.5603 |
-15.0652 |
0.0650 |
|
|
4.5174 |
-15.0615 |
0.0475 |
(For x, y corrected coordinates, use SLAC data if available. If not, use IHEP data.)
|
Fiducial – Corrected Coordinates |
z |
x |
y |
|
(in) |
(in) |
(in) |
|
|
TB1 |
|
|
|
|
TB2 |
|
|
|
|
TB3 |
|
|
|
|
TB4 |
|
|
|
|
TB5 |
|
|
|
|
TB6 |
|
|
|
Check Measurements:
|
Flat Center |
xmeasured |
xnominal |
ymeasured |
ynominal |
|
Upstream |
|
0.0 in |
|
12.8 in |
|
Downstream |
|
0.0 in |
|
12.8 in |
|
Position 1 (x,y)=(0,0) |
x (in) |
y (in) |
|
-0.0008 |
-0.0008 |
|
|
0.0021 |
-0.0014 |
|
|
0.0019 |
-0.0004 |
|
|
0.0020 |
-0.0001 |
|
|
0.0005 |
-0.0005 |
Approval ________________________