SLAC Magnetic Measurements Date: 07-28-2021 Time: 15:03:00 Project: LCLS-II Device Type: Reference magnet Data Type: Serial Number: SENTRON_463 Run Number: 71 Measurement Type: Run Operator: YL Comment: SXU_021, DS 002, life-time test; after 200 cycles; re-calibrated -5.537520 -0.381821 0.131939 -0.381788 -0.000206 -0.381787 -5.537461 -0.381831 0.132144 -0.381806 -0.000225 -0.381801 Field = -0.382255 Not adjusted for T -5.537395 -0.381835 0.132156 -0.381819 -0.000274 -0.381821 -5.537283 -0.381829 0.132046 -0.381848 -0.000343 -0.381848 Field = -0.382302 Not adjusted for T