SLAC Magnetic Measurements Date: 05-24-2016 Time: 16:18:18 Project: SSRL Magnet Type: Septum Magnet Name: B9V2 Serial Number: Run Number: 21 Measurement Device: 1wire Operator: sda Comment: By vs x intrgral in field free region. Currents = 233 A. Scan from 12 to 3.5 in septum coordinates. Wire x = 0 is septum +17.5 mm Standardization for B9V2: 3 cycles from 0.0 A to 265.0 A to 0.0 A Test Currents for B9V2 (A): 233.00 16:18:38 Stage Position Measurement, x_pos = 0.000000 m, y_pos = 0.000000 m 16:18:42 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 16:18:42 MoveXY Devices: Move Device = ESP300, Read Device = ESP300 16:19:09 Position moved: 0.000000 m 16:19:40 Magnet Current for B9V2, Imag = -0.0009 A Vtrans = -0.000009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:41 Magnet Current for B9V2, Imag = -0.0010 A Vtrans = -0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:41 Magnet Current for B9V2, Imag = -0.0010 A Vtrans = -0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:41 Magnet Avgerage Current Measurement for B9V2 : Imag = -0.0010 +- 0.0000 A 16:20:06 Initial Zero Current Measurement for B9V2, Imag_zero = -0.000966167 A 16:20:06 Ambient Measurement Device(s) Being Used, type = None 16:20:06 Magnet Voltage Measurement Device(s) Being Used, type = None 16:20:06 Temperature Measurement Device(s) Being Used, type = None 16:20:06 XMAG Device(s) Being Used, type = None 16:20:06 Ambient Measurement Device(s) Being Used, type = None 16:20:06 Magnet system B9V2 current ramping to 265.0000 A... 16:23:06 Magnet system B9V2 current ramping to 0.0000 A... 16:26:07 Magnet system B9V2 current ramping to 265.0000 A... 16:29:07 Magnet system B9V2 current ramping to 0.0000 A... 16:32:08 Magnet system B9V2 current ramping to 265.0000 A... 16:35:08 Magnet system B9V2 current ramping to 0.0000 A... 16:38:12 Position moved: 0.000000 m 16:38:15 Magnet system B9V2 current ramping to 233.0000 A... 16:39:23 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 16:39:23 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:39:23 ‰” Voltage Measurement, V = 0.000000 V 16:39:23 Magnet Test Parameter Measurements P0 = B9V2, Value = 233.10 16:39:24 Integrated Voltage Measurement... 16:39:24 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:39:32 Voltage Offset Correction: v_off_ini = 0.000022857 V, v_off_fin = 0.000022460 V 16:39:32 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000378 Vs 16:39:38 Voltage Offset Correction: v_off_ini = 0.000016259 V, v_off_fin = 0.000015974 V 16:39:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000411 Vs 16:39:39 Magnet Current for B9V2, Imag = 233.1029 A Vtrans = 2.331019 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:39:45 Voltage Offset Correction: v_off_ini = 0.000011593 V, v_off_fin = 0.000011395 V 16:39:45 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000431 Vs 16:39:51 Voltage Offset Correction: v_off_ini = 0.000008447 V, v_off_fin = 0.000008320 V 16:39:51 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000470 Vs 16:39:52 Magnet Current for B9V2, Imag = 233.1029 A Vtrans = 2.331019 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:39:58 Voltage Offset Correction: v_off_ini = 0.000005895 V, v_off_fin = 0.000005593 V 16:39:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000494 Vs 16:40:04 Voltage Offset Correction: v_off_ini = 0.000003937 V, v_off_fin = 0.000003885 V 16:40:04 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000474 Vs 16:40:05 Magnet Current for B9V2, Imag = 233.1035 A Vtrans = 2.331025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:40:11 Voltage Offset Correction: v_off_ini = 0.000002533 V, v_off_fin = 0.000003299 V 16:40:11 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000610 Vs 16:40:17 Voltage Offset Correction: v_off_ini = 0.000001742 V, v_off_fin = 0.000001738 V 16:40:17 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000489 Vs 16:40:18 Magnet Current for B9V2, Imag = 233.1033 A Vtrans = 2.331023 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:40:24 Voltage Offset Correction: v_off_ini = 0.000000948 V, v_off_fin = 0.000000929 V 16:40:24 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000541 Vs 16:40:30 Voltage Offset Correction: v_off_ini = 0.000000601 V, v_off_fin = 0.000000977 V 16:40:30 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000539 Vs 16:40:31 Magnet Current for B9V2, Imag = 233.1031 A Vtrans = 2.331022 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:40:37 Voltage Offset Correction: v_off_ini = -0.000000244 V, v_off_fin = -0.000000247 V 16:40:37 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000508 Vs 16:40:44 Voltage Offset Correction: v_off_ini = -0.000000420 V, v_off_fin = -0.000000269 V 16:40:44 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000560 Vs 16:40:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000492 +- 0.000000056 Vs 16:40:44 First Field Integral, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000492 +- 0.000000056 Vs FI1 = 0.00098433 +- 0.00011142 Tm 16:40:44 Integrated Voltage Measurement... 16:40:44 Magnet Current for B9V2, Imag = 233.1031 A Vtrans = 2.331022 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:40:52 Voltage Offset Correction: v_off_ini = -0.000000836 V, v_off_fin = -0.000000805 V 16:40:52 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 16:40:58 Voltage Offset Correction: v_off_ini = -0.000001000 V, v_off_fin = -0.000001039 V 16:40:58 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000528 Vs 16:40:59 Magnet Current for B9V2, Imag = 233.1031 A Vtrans = 2.331022 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:41:05 Voltage Offset Correction: v_off_ini = -0.000001056 V, v_off_fin = -0.000000847 V 16:41:05 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000493 Vs 16:41:11 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000001091 V 16:41:11 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000492 Vs 16:41:12 Magnet Current for B9V2, Imag = 233.1033 A Vtrans = 2.331023 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:41:18 Voltage Offset Correction: v_off_ini = -0.000001245 V, v_off_fin = -0.000001346 V 16:41:18 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000512 Vs 16:41:24 Voltage Offset Correction: v_off_ini = -0.000001430 V, v_off_fin = -0.000001307 V 16:41:24 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000539 Vs 16:41:25 Magnet Current for B9V2, Imag = 233.1029 A Vtrans = 2.331019 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:41:31 Voltage Offset Correction: v_off_ini = -0.000001364 V, v_off_fin = -0.000001505 V 16:41:31 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000524 Vs 16:41:37 Voltage Offset Correction: v_off_ini = -0.000001470 V, v_off_fin = -0.000001613 V 16:41:37 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000531 Vs 16:41:38 Magnet Current for B9V2, Imag = 233.1030 A Vtrans = 2.331020 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:41:44 Voltage Offset Correction: v_off_ini = -0.000001602 V, v_off_fin = -0.000001542 V 16:41:44 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000519 Vs 16:41:50 Voltage Offset Correction: v_off_ini = -0.000001460 V, v_off_fin = -0.000001428 V 16:41:50 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000522 Vs 16:41:51 Magnet Current for B9V2, Imag = 233.1027 A Vtrans = 2.331018 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:41:57 Voltage Offset Correction: v_off_ini = -0.000001421 V, v_off_fin = -0.000001541 V 16:41:57 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000518 Vs 16:42:03 Voltage Offset Correction: v_off_ini = -0.000001707 V, v_off_fin = -0.000001432 V 16:42:03 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000544 Vs 16:42:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000519 +- 0.000000013 Vs 16:42:03 First Field Integral, Average and RMS of Measurements X0 = 0.0055000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000519 +- 0.000000013 Vs FI1 = 0.00103879 +- 0.00002531 Tm 16:42:03 Integrated Voltage Measurement... 16:42:04 Magnet Current for B9V2, Imag = 233.1026 A Vtrans = 2.331017 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:42:11 Voltage Offset Correction: v_off_ini = -0.000001629 V, v_off_fin = -0.000001618 V 16:42:11 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000511 Vs 16:42:18 Voltage Offset Correction: v_off_ini = -0.000001599 V, v_off_fin = -0.000001733 V 16:42:18 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000552 Vs 16:42:18 Magnet Current for B9V2, Imag = 233.1025 A Vtrans = 2.331015 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:42:24 Voltage Offset Correction: v_off_ini = -0.000001703 V, v_off_fin = -0.000001343 V 16:42:24 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000481 Vs 16:42:31 Voltage Offset Correction: v_off_ini = -0.000001707 V, v_off_fin = -0.000001658 V 16:42:31 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000531 Vs 16:42:31 Magnet Current for B9V2, Imag = 233.1026 A Vtrans = 2.331017 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:42:38 Voltage Offset Correction: v_off_ini = -0.000001646 V, v_off_fin = -0.000001500 V 16:42:38 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000497 Vs 16:42:44 Voltage Offset Correction: v_off_ini = -0.000001758 V, v_off_fin = -0.000002016 V 16:42:44 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000470 Vs 16:42:45 Magnet Current for B9V2, Imag = 233.1026 A Vtrans = 2.331017 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:42:51 Voltage Offset Correction: v_off_ini = -0.000001597 V, v_off_fin = -0.000001420 V 16:42:51 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000533 Vs 16:42:57 Voltage Offset Correction: v_off_ini = -0.000001620 V, v_off_fin = -0.000001668 V 16:42:57 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 16:42:58 Magnet Current for B9V2, Imag = 233.1024 A Vtrans = 2.331014 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:43:04 Voltage Offset Correction: v_off_ini = -0.000001533 V, v_off_fin = -0.000000975 V 16:43:04 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000479 Vs 16:43:10 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000001305 V 16:43:10 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000544 Vs 16:43:11 Magnet Current for B9V2, Imag = 233.1022 A Vtrans = 2.331013 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:43:17 Voltage Offset Correction: v_off_ini = -0.000001803 V, v_off_fin = -0.000001858 V 16:43:17 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000530 Vs 16:43:23 Voltage Offset Correction: v_off_ini = -0.000001719 V, v_off_fin = -0.000001693 V 16:43:23 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000504 Vs 16:43:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000513 +- 0.000000016 Vs 16:43:23 First Field Integral, Average and RMS of Measurements X0 = 0.0060000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000513 +- 0.000000016 Vs FI1 = 0.00102593 +- 0.00003178 Tm 16:43:23 Integrated Voltage Measurement... 16:43:24 Magnet Current for B9V2, Imag = 233.1021 A Vtrans = 2.331011 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:43:31 Voltage Offset Correction: v_off_ini = -0.000001648 V, v_off_fin = -0.000001713 V 16:43:31 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000553 Vs 16:43:38 Voltage Offset Correction: v_off_ini = -0.000001871 V, v_off_fin = -0.000001841 V 16:43:38 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000570 Vs 16:43:38 Magnet Current for B9V2, Imag = 233.1018 A Vtrans = 2.331009 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:43:44 Voltage Offset Correction: v_off_ini = -0.000001690 V, v_off_fin = -0.000001920 V 16:43:45 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000510 Vs 16:43:51 Voltage Offset Correction: v_off_ini = -0.000001658 V, v_off_fin = -0.000001643 V 16:43:51 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000517 Vs 16:43:51 Magnet Current for B9V2, Imag = 233.1021 A Vtrans = 2.331011 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:43:58 Voltage Offset Correction: v_off_ini = -0.000001743 V, v_off_fin = -0.000001855 V 16:43:58 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000503 Vs 16:44:04 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000001650 V 16:44:04 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000518 Vs 16:44:05 Magnet Current for B9V2, Imag = 233.1016 A Vtrans = 2.331006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:44:11 Voltage Offset Correction: v_off_ini = -0.000001855 V, v_off_fin = -0.000001880 V 16:44:11 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 16:44:17 Voltage Offset Correction: v_off_ini = -0.000001742 V, v_off_fin = -0.000001830 V 16:44:17 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000550 Vs 16:44:18 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:44:24 Voltage Offset Correction: v_off_ini = -0.000001494 V, v_off_fin = -0.000001246 V 16:44:24 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000473 Vs 16:44:30 Voltage Offset Correction: v_off_ini = -0.000001850 V, v_off_fin = -0.000001899 V 16:44:30 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000611 Vs 16:44:31 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:44:37 Voltage Offset Correction: v_off_ini = -0.000001834 V, v_off_fin = -0.000001756 V 16:44:37 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000485 Vs 16:44:43 Voltage Offset Correction: v_off_ini = -0.000001651 V, v_off_fin = -0.000001662 V 16:44:43 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000474 Vs 16:44:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000523 +- 0.000000026 Vs 16:44:43 First Field Integral, Average and RMS of Measurements X0 = 0.0065000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000523 +- 0.000000026 Vs FI1 = 0.00104573 +- 0.00005173 Tm 16:44:43 Integrated Voltage Measurement... 16:44:44 Magnet Current for B9V2, Imag = 233.1017 A Vtrans = 2.331008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:44:51 Voltage Offset Correction: v_off_ini = -0.000001781 V, v_off_fin = -0.000001996 V 16:44:51 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000495 Vs 16:44:58 Voltage Offset Correction: v_off_ini = -0.000001692 V, v_off_fin = -0.000001726 V 16:44:58 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000527 Vs 16:44:58 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:45:05 Voltage Offset Correction: v_off_ini = -0.000001642 V, v_off_fin = -0.000001563 V 16:45:05 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000540 Vs 16:45:11 Voltage Offset Correction: v_off_ini = -0.000001652 V, v_off_fin = -0.000001648 V 16:45:11 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000526 Vs 16:45:12 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:45:18 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = -0.000001407 V 16:45:18 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000575 Vs 16:45:24 Voltage Offset Correction: v_off_ini = -0.000001834 V, v_off_fin = -0.000001701 V 16:45:24 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000535 Vs 16:45:25 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:45:31 Voltage Offset Correction: v_off_ini = -0.000001709 V, v_off_fin = -0.000001717 V 16:45:31 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 16:45:37 Voltage Offset Correction: v_off_ini = -0.000001612 V, v_off_fin = -0.000001638 V 16:45:37 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000537 Vs 16:45:38 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:45:44 Voltage Offset Correction: v_off_ini = -0.000001566 V, v_off_fin = -0.000001570 V 16:45:44 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000499 Vs 16:45:50 Voltage Offset Correction: v_off_ini = -0.000001525 V, v_off_fin = -0.000001630 V 16:45:50 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000532 Vs 16:45:51 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:45:57 Voltage Offset Correction: v_off_ini = -0.000001563 V, v_off_fin = -0.000001568 V 16:45:57 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000512 Vs 16:46:03 Voltage Offset Correction: v_off_ini = -0.000001773 V, v_off_fin = -0.000001908 V 16:46:03 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000495 Vs 16:46:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000523 +- 0.000000017 Vs 16:46:03 First Field Integral, Average and RMS of Measurements X0 = 0.0070000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000523 +- 0.000000017 Vs FI1 = 0.00104680 +- 0.00003422 Tm 16:46:03 Integrated Voltage Measurement... 16:46:04 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:46:11 Voltage Offset Correction: v_off_ini = -0.000001772 V, v_off_fin = -0.000001546 V 16:46:11 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 16:46:18 Voltage Offset Correction: v_off_ini = -0.000001707 V, v_off_fin = -0.000001556 V 16:46:18 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000538 Vs 16:46:18 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:46:25 Voltage Offset Correction: v_off_ini = -0.000001504 V, v_off_fin = -0.000001584 V 16:46:25 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000562 Vs 16:46:31 Voltage Offset Correction: v_off_ini = -0.000001862 V, v_off_fin = -0.000001942 V 16:46:31 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000538 Vs 16:46:31 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:46:38 Voltage Offset Correction: v_off_ini = -0.000001514 V, v_off_fin = -0.000001713 V 16:46:38 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000561 Vs 16:46:44 Voltage Offset Correction: v_off_ini = -0.000001547 V, v_off_fin = -0.000001512 V 16:46:44 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000590 Vs 16:46:45 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:46:51 Voltage Offset Correction: v_off_ini = -0.000001711 V, v_off_fin = -0.000001775 V 16:46:51 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 16:46:57 Voltage Offset Correction: v_off_ini = -0.000001704 V, v_off_fin = -0.000001596 V 16:46:57 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000525 Vs 16:46:58 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:47:04 Voltage Offset Correction: v_off_ini = -0.000002075 V, v_off_fin = -0.000002051 V 16:47:04 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000539 Vs 16:47:10 Voltage Offset Correction: v_off_ini = -0.000001695 V, v_off_fin = -0.000001712 V 16:47:10 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000555 Vs 16:47:11 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:47:17 Voltage Offset Correction: v_off_ini = -0.000001569 V, v_off_fin = -0.000001448 V 16:47:17 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000499 Vs 16:47:23 Voltage Offset Correction: v_off_ini = -0.000001702 V, v_off_fin = -0.000001813 V 16:47:23 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 16:47:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000544 +- 0.000000016 Vs 16:47:23 First Field Integral, Average and RMS of Measurements X0 = 0.0075000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000544 +- 0.000000016 Vs FI1 = 0.00108891 +- 0.00003203 Tm 16:47:23 Integrated Voltage Measurement... 16:47:24 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:47:31 Voltage Offset Correction: v_off_ini = -0.000001571 V, v_off_fin = -0.000001800 V 16:47:31 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000557 Vs 16:47:38 Voltage Offset Correction: v_off_ini = -0.000001651 V, v_off_fin = -0.000001799 V 16:47:38 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000538 Vs 16:47:38 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:47:45 Voltage Offset Correction: v_off_ini = -0.000001710 V, v_off_fin = -0.000002062 V 16:47:45 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000570 Vs 16:47:51 Voltage Offset Correction: v_off_ini = -0.000001810 V, v_off_fin = -0.000002010 V 16:47:51 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000556 Vs 16:47:52 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:47:58 Voltage Offset Correction: v_off_ini = -0.000001816 V, v_off_fin = -0.000001712 V 16:47:58 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000543 Vs 16:48:04 Voltage Offset Correction: v_off_ini = -0.000001619 V, v_off_fin = -0.000001582 V 16:48:04 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000552 Vs 16:48:05 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:48:11 Voltage Offset Correction: v_off_ini = -0.000001744 V, v_off_fin = -0.000001720 V 16:48:11 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000529 Vs 16:48:17 Voltage Offset Correction: v_off_ini = -0.000001814 V, v_off_fin = -0.000001806 V 16:48:17 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000542 Vs 16:48:18 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:48:24 Voltage Offset Correction: v_off_ini = -0.000001715 V, v_off_fin = -0.000001824 V 16:48:24 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000503 Vs 16:48:30 Voltage Offset Correction: v_off_ini = -0.000001625 V, v_off_fin = -0.000001510 V 16:48:30 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000558 Vs 16:48:31 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:48:37 Voltage Offset Correction: v_off_ini = -0.000001676 V, v_off_fin = -0.000001692 V 16:48:37 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000553 Vs 16:48:43 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000001291 V 16:48:43 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000560 Vs 16:48:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000547 +- 0.000000011 Vs 16:48:43 First Field Integral, Average and RMS of Measurements X0 = 0.0080000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000547 +- 0.000000011 Vs FI1 = 0.00109344 +- 0.00002270 Tm 16:48:44 Integrated Voltage Measurement... 16:48:44 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:48:52 Voltage Offset Correction: v_off_ini = -0.000001698 V, v_off_fin = -0.000001619 V 16:48:52 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000522 Vs 16:48:58 Voltage Offset Correction: v_off_ini = -0.000001687 V, v_off_fin = -0.000001675 V 16:48:58 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000543 Vs 16:48:58 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:49:05 Voltage Offset Correction: v_off_ini = -0.000001629 V, v_off_fin = -0.000001647 V 16:49:05 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000517 Vs 16:49:11 Voltage Offset Correction: v_off_ini = -0.000001838 V, v_off_fin = -0.000001792 V 16:49:11 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000530 Vs 16:49:12 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:49:18 Voltage Offset Correction: v_off_ini = -0.000001764 V, v_off_fin = -0.000001429 V 16:49:18 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000575 Vs 16:49:24 Voltage Offset Correction: v_off_ini = -0.000001841 V, v_off_fin = -0.000001790 V 16:49:24 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000550 Vs 16:49:25 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:49:31 Voltage Offset Correction: v_off_ini = -0.000001920 V, v_off_fin = -0.000001901 V 16:49:31 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000529 Vs 16:49:37 Voltage Offset Correction: v_off_ini = -0.000001741 V, v_off_fin = -0.000001317 V 16:49:37 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000596 Vs 16:49:38 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:49:44 Voltage Offset Correction: v_off_ini = -0.000001797 V, v_off_fin = -0.000001846 V 16:49:44 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000512 Vs 16:49:50 Voltage Offset Correction: v_off_ini = -0.000001760 V, v_off_fin = -0.000001875 V 16:49:50 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000556 Vs 16:49:51 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:49:57 Voltage Offset Correction: v_off_ini = -0.000001791 V, v_off_fin = -0.000001851 V 16:49:57 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000526 Vs 16:50:03 Voltage Offset Correction: v_off_ini = -0.000001627 V, v_off_fin = -0.000001622 V 16:50:03 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000566 Vs 16:50:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000544 +- 0.000000015 Vs 16:50:03 First Field Integral, Average and RMS of Measurements X0 = 0.0085000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000544 +- 0.000000015 Vs FI1 = 0.00108703 +- 0.00003005 Tm 16:50:03 Integrated Voltage Measurement... 16:50:04 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:50:12 Voltage Offset Correction: v_off_ini = -0.000001895 V, v_off_fin = -0.000001879 V 16:50:12 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000550 Vs 16:50:18 Voltage Offset Correction: v_off_ini = -0.000001731 V, v_off_fin = -0.000001783 V 16:50:18 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 16:50:18 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:50:25 Voltage Offset Correction: v_off_ini = -0.000001788 V, v_off_fin = -0.000001795 V 16:50:25 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 16:50:31 Voltage Offset Correction: v_off_ini = -0.000001843 V, v_off_fin = -0.000001756 V 16:50:31 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000562 Vs 16:50:32 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:50:38 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000001817 V 16:50:38 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000541 Vs 16:50:44 Voltage Offset Correction: v_off_ini = -0.000001673 V, v_off_fin = -0.000001765 V 16:50:44 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 16:50:45 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:50:51 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = -0.000001837 V 16:50:51 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000549 Vs 16:50:57 Voltage Offset Correction: v_off_ini = -0.000001823 V, v_off_fin = -0.000001754 V 16:50:57 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000549 Vs 16:50:58 Magnet Current for B9V2, Imag = 233.0998 A Vtrans = 2.330988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:51:04 Voltage Offset Correction: v_off_ini = -0.000001865 V, v_off_fin = -0.000001891 V 16:51:04 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000543 Vs 16:51:10 Voltage Offset Correction: v_off_ini = -0.000001877 V, v_off_fin = -0.000001632 V 16:51:10 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000566 Vs 16:51:11 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:51:17 Voltage Offset Correction: v_off_ini = -0.000001723 V, v_off_fin = -0.000001803 V 16:51:17 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000539 Vs 16:51:23 Voltage Offset Correction: v_off_ini = -0.000001540 V, v_off_fin = -0.000001476 V 16:51:23 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000548 Vs 16:51:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000548 +- 0.000000008 Vs 16:51:23 First Field Integral, Average and RMS of Measurements X0 = 0.0090000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000548 +- 0.000000008 Vs FI1 = 0.00109562 +- 0.00001601 Tm 16:51:23 Integrated Voltage Measurement... 16:51:24 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:51:31 Voltage Offset Correction: v_off_ini = -0.000001749 V, v_off_fin = -0.000001948 V 16:51:31 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000604 Vs 16:51:37 Voltage Offset Correction: v_off_ini = -0.000001691 V, v_off_fin = -0.000001865 V 16:51:38 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000546 Vs 16:51:38 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:51:44 Voltage Offset Correction: v_off_ini = -0.000001506 V, v_off_fin = -0.000001363 V 16:51:44 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000585 Vs 16:51:51 Voltage Offset Correction: v_off_ini = -0.000001613 V, v_off_fin = -0.000001764 V 16:51:51 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000603 Vs 16:51:51 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:51:58 Voltage Offset Correction: v_off_ini = -0.000001650 V, v_off_fin = -0.000001749 V 16:51:58 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000571 Vs 16:52:04 Voltage Offset Correction: v_off_ini = -0.000001554 V, v_off_fin = -0.000001371 V 16:52:04 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000536 Vs 16:52:05 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:52:11 Voltage Offset Correction: v_off_ini = -0.000001484 V, v_off_fin = -0.000001596 V 16:52:11 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000580 Vs 16:52:17 Voltage Offset Correction: v_off_ini = -0.000001540 V, v_off_fin = -0.000001604 V 16:52:17 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000525 Vs 16:52:18 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:52:24 Voltage Offset Correction: v_off_ini = -0.000001621 V, v_off_fin = -0.000001796 V 16:52:24 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000524 Vs 16:52:30 Voltage Offset Correction: v_off_ini = -0.000001656 V, v_off_fin = -0.000001668 V 16:52:30 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000559 Vs 16:52:31 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:52:37 Voltage Offset Correction: v_off_ini = -0.000001548 V, v_off_fin = -0.000001391 V 16:52:37 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000539 Vs 16:52:43 Voltage Offset Correction: v_off_ini = -0.000001749 V, v_off_fin = -0.000001589 V 16:52:43 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 16:52:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000560 +- 0.000000019 Vs 16:52:43 First Field Integral, Average and RMS of Measurements X0 = 0.0095000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000560 +- 0.000000019 Vs FI1 = 0.00111923 +- 0.00003767 Tm 16:52:43 Integrated Voltage Measurement... 16:52:44 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:52:52 Voltage Offset Correction: v_off_ini = -0.000001599 V, v_off_fin = -0.000001701 V 16:52:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000534 Vs 16:52:58 Voltage Offset Correction: v_off_ini = -0.000001592 V, v_off_fin = -0.000001552 V 16:52:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000583 Vs 16:52:58 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:53:05 Voltage Offset Correction: v_off_ini = -0.000001808 V, v_off_fin = -0.000001837 V 16:53:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000561 Vs 16:53:11 Voltage Offset Correction: v_off_ini = -0.000001635 V, v_off_fin = -0.000001575 V 16:53:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000552 Vs 16:53:12 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:53:18 Voltage Offset Correction: v_off_ini = -0.000001737 V, v_off_fin = -0.000001687 V 16:53:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000549 Vs 16:53:24 Voltage Offset Correction: v_off_ini = -0.000001567 V, v_off_fin = -0.000001584 V 16:53:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000551 Vs 16:53:25 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:53:31 Voltage Offset Correction: v_off_ini = -0.000001769 V, v_off_fin = -0.000001391 V 16:53:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 16:53:37 Voltage Offset Correction: v_off_ini = -0.000001752 V, v_off_fin = -0.000001727 V 16:53:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000565 Vs 16:53:38 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:53:44 Voltage Offset Correction: v_off_ini = -0.000001677 V, v_off_fin = -0.000001540 V 16:53:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000545 Vs 16:53:50 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000001899 V 16:53:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000583 Vs 16:53:51 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:53:57 Voltage Offset Correction: v_off_ini = -0.000001890 V, v_off_fin = -0.000001936 V 16:53:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000565 Vs 16:54:03 Voltage Offset Correction: v_off_ini = -0.000001738 V, v_off_fin = -0.000001626 V 16:54:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000584 Vs 16:54:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000557 +- 0.000000012 Vs 16:54:03 First Field Integral, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000557 +- 0.000000012 Vs FI1 = 0.00111319 +- 0.00002328 Tm 16:54:03 Integrated Voltage Measurement... 16:54:04 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:54:12 Voltage Offset Correction: v_off_ini = -0.000001774 V, v_off_fin = -0.000001883 V 16:54:12 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000561 Vs 16:54:18 Voltage Offset Correction: v_off_ini = -0.000001839 V, v_off_fin = -0.000001750 V 16:54:18 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000572 Vs 16:54:18 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:54:25 Voltage Offset Correction: v_off_ini = -0.000001753 V, v_off_fin = -0.000001697 V 16:54:25 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000584 Vs 16:54:31 Voltage Offset Correction: v_off_ini = -0.000001684 V, v_off_fin = -0.000001556 V 16:54:31 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000548 Vs 16:54:31 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:54:38 Voltage Offset Correction: v_off_ini = -0.000002258 V, v_off_fin = -0.000002318 V 16:54:38 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000534 Vs 16:54:44 Voltage Offset Correction: v_off_ini = -0.000001743 V, v_off_fin = -0.000001758 V 16:54:44 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000562 Vs 16:54:45 Magnet Current for B9V2, Imag = 233.0997 A Vtrans = 2.330987 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:54:51 Voltage Offset Correction: v_off_ini = -0.000001966 V, v_off_fin = -0.000001616 V 16:54:51 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 16:54:57 Voltage Offset Correction: v_off_ini = -0.000001955 V, v_off_fin = -0.000001965 V 16:54:57 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000505 Vs 16:54:58 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:55:04 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000001683 V 16:55:04 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000533 Vs 16:55:10 Voltage Offset Correction: v_off_ini = -0.000001693 V, v_off_fin = -0.000001599 V 16:55:10 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000569 Vs 16:55:11 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:55:17 Voltage Offset Correction: v_off_ini = -0.000001642 V, v_off_fin = -0.000001578 V 16:55:17 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 16:55:23 Voltage Offset Correction: v_off_ini = -0.000001784 V, v_off_fin = -0.000001602 V 16:55:23 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000579 Vs 16:55:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000554 +- 0.000000014 Vs 16:55:23 First Field Integral, Average and RMS of Measurements X0 = 0.0105000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000554 +- 0.000000014 Vs FI1 = 0.00110709 +- 0.00002811 Tm 16:55:23 Integrated Voltage Measurement... 16:55:24 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:55:31 Voltage Offset Correction: v_off_ini = -0.000001576 V, v_off_fin = -0.000001897 V 16:55:31 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 16:55:37 Voltage Offset Correction: v_off_ini = -0.000001557 V, v_off_fin = -0.000001353 V 16:55:38 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000589 Vs 16:55:38 Magnet Current for B9V2, Imag = 233.0998 A Vtrans = 2.330988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:55:44 Voltage Offset Correction: v_off_ini = -0.000001525 V, v_off_fin = -0.000001701 V 16:55:44 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000546 Vs 16:55:51 Voltage Offset Correction: v_off_ini = -0.000001515 V, v_off_fin = -0.000001204 V 16:55:51 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000596 Vs 16:55:51 Magnet Current for B9V2, Imag = 233.0997 A Vtrans = 2.330987 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:55:57 Voltage Offset Correction: v_off_ini = -0.000001677 V, v_off_fin = -0.000001831 V 16:55:57 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000519 Vs 16:56:04 Voltage Offset Correction: v_off_ini = -0.000001594 V, v_off_fin = -0.000001783 V 16:56:04 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000456 Vs 16:56:04 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:56:11 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000001456 V 16:56:11 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 16:56:17 Voltage Offset Correction: v_off_ini = -0.000001533 V, v_off_fin = -0.000001280 V 16:56:17 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000556 Vs 16:56:17 Magnet Current for B9V2, Imag = 233.0998 A Vtrans = 2.330988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:56:24 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000001542 V 16:56:24 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000564 Vs 16:56:30 Voltage Offset Correction: v_off_ini = -0.000001579 V, v_off_fin = -0.000001647 V 16:56:30 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000554 Vs 16:56:31 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:56:37 Voltage Offset Correction: v_off_ini = -0.000001691 V, v_off_fin = -0.000001905 V 16:56:37 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000558 Vs 16:56:43 Voltage Offset Correction: v_off_ini = -0.000001869 V, v_off_fin = -0.000001745 V 16:56:43 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000536 Vs 16:56:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000545 +- 0.000000028 Vs 16:56:43 First Field Integral, Average and RMS of Measurements X0 = 0.0110000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000545 +- 0.000000028 Vs FI1 = 0.00109081 +- 0.00005623 Tm 16:56:43 Integrated Voltage Measurement... 16:56:44 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:56:51 Voltage Offset Correction: v_off_ini = -0.000001695 V, v_off_fin = -0.000001481 V 16:56:51 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000538 Vs 16:56:57 Voltage Offset Correction: v_off_ini = -0.000001563 V, v_off_fin = -0.000001805 V 16:56:57 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000532 Vs 16:56:58 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:57:04 Voltage Offset Correction: v_off_ini = -0.000001572 V, v_off_fin = -0.000001865 V 16:57:04 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000573 Vs 16:57:10 Voltage Offset Correction: v_off_ini = -0.000001585 V, v_off_fin = -0.000001728 V 16:57:10 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 16:57:11 Magnet Current for B9V2, Imag = 233.0997 A Vtrans = 2.330987 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:57:17 Voltage Offset Correction: v_off_ini = -0.000001532 V, v_off_fin = -0.000001691 V 16:57:17 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000525 Vs 16:57:23 Voltage Offset Correction: v_off_ini = -0.000001551 V, v_off_fin = -0.000001366 V 16:57:23 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000588 Vs 16:57:24 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:57:30 Voltage Offset Correction: v_off_ini = -0.000001371 V, v_off_fin = -0.000001400 V 16:57:30 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000520 Vs 16:57:37 Voltage Offset Correction: v_off_ini = -0.000001754 V, v_off_fin = -0.000001841 V 16:57:37 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000551 Vs 16:57:37 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:57:43 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = -0.000001529 V 16:57:43 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000551 Vs 16:57:50 Voltage Offset Correction: v_off_ini = -0.000001554 V, v_off_fin = -0.000001469 V 16:57:50 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000551 Vs 16:57:50 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:57:56 Voltage Offset Correction: v_off_ini = -0.000001420 V, v_off_fin = -0.000001478 V 16:57:57 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 16:58:03 Voltage Offset Correction: v_off_ini = -0.000001304 V, v_off_fin = -0.000001192 V 16:58:03 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000542 Vs 16:58:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000547 +- 0.000000010 Vs 16:58:03 First Field Integral, Average and RMS of Measurements X0 = 0.0115000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000547 +- 0.000000010 Vs FI1 = 0.00109393 +- 0.00001910 Tm 16:58:03 Integrated Voltage Measurement... 16:58:04 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:58:11 Voltage Offset Correction: v_off_ini = -0.000001787 V, v_off_fin = -0.000001684 V 16:58:11 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000515 Vs 16:58:17 Voltage Offset Correction: v_off_ini = -0.000001533 V, v_off_fin = -0.000001546 V 16:58:17 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000547 Vs 16:58:18 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:58:24 Voltage Offset Correction: v_off_ini = -0.000001485 V, v_off_fin = -0.000001383 V 16:58:24 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000581 Vs 16:58:30 Voltage Offset Correction: v_off_ini = -0.000001667 V, v_off_fin = -0.000001772 V 16:58:30 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000543 Vs 16:58:31 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:58:37 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000001612 V 16:58:37 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000584 Vs 16:58:43 Voltage Offset Correction: v_off_ini = -0.000001456 V, v_off_fin = -0.000001389 V 16:58:43 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000539 Vs 16:58:44 Magnet Current for B9V2, Imag = 233.0998 A Vtrans = 2.330988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:58:50 Voltage Offset Correction: v_off_ini = -0.000001432 V, v_off_fin = -0.000001351 V 16:58:50 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000557 Vs 16:58:57 Voltage Offset Correction: v_off_ini = -0.000001670 V, v_off_fin = -0.000001731 V 16:58:57 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000543 Vs 16:58:57 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:59:04 Voltage Offset Correction: v_off_ini = -0.000001409 V, v_off_fin = -0.000001660 V 16:59:04 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000496 Vs 16:59:10 Voltage Offset Correction: v_off_ini = -0.000001768 V, v_off_fin = -0.000001587 V 16:59:10 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000536 Vs 16:59:11 Magnet Current for B9V2, Imag = 233.0998 A Vtrans = 2.330988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:59:17 Voltage Offset Correction: v_off_ini = -0.000001660 V, v_off_fin = -0.000001864 V 16:59:17 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000521 Vs 16:59:23 Voltage Offset Correction: v_off_ini = -0.000001839 V, v_off_fin = -0.000001832 V 16:59:23 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000588 Vs 16:59:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000546 +- 0.000000017 Vs 16:59:23 First Field Integral, Average and RMS of Measurements X0 = 0.0120000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000546 +- 0.000000017 Vs FI1 = 0.00109172 +- 0.00003361 Tm 16:59:23 Integrated Voltage Measurement... 16:59:24 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:59:31 Voltage Offset Correction: v_off_ini = -0.000001475 V, v_off_fin = -0.000001611 V 16:59:31 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000533 Vs 16:59:37 Voltage Offset Correction: v_off_ini = -0.000001652 V, v_off_fin = -0.000001851 V 16:59:37 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000528 Vs 16:59:38 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:59:44 Voltage Offset Correction: v_off_ini = -0.000001568 V, v_off_fin = -0.000001719 V 16:59:44 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000535 Vs 16:59:50 Voltage Offset Correction: v_off_ini = -0.000001753 V, v_off_fin = -0.000001684 V 16:59:50 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000532 Vs 16:59:51 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 16:59:57 Voltage Offset Correction: v_off_ini = -0.000001472 V, v_off_fin = -0.000001639 V 16:59:57 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000545 Vs 17:00:03 Voltage Offset Correction: v_off_ini = -0.000001706 V, v_off_fin = -0.000001438 V 17:00:03 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000574 Vs 17:00:04 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:00:10 Voltage Offset Correction: v_off_ini = -0.000001553 V, v_off_fin = -0.000001438 V 17:00:10 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000493 Vs 17:00:17 Voltage Offset Correction: v_off_ini = -0.000001591 V, v_off_fin = -0.000001964 V 17:00:17 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 17:00:17 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:00:24 Voltage Offset Correction: v_off_ini = -0.000001754 V, v_off_fin = -0.000001937 V 17:00:24 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000507 Vs 17:00:30 Voltage Offset Correction: v_off_ini = -0.000001625 V, v_off_fin = -0.000001434 V 17:00:30 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000541 Vs 17:00:30 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:00:37 Voltage Offset Correction: v_off_ini = -0.000001537 V, v_off_fin = -0.000001749 V 17:00:37 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000532 Vs 17:00:43 Voltage Offset Correction: v_off_ini = -0.000001758 V, v_off_fin = -0.000001856 V 17:00:43 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000493 Vs 17:00:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000530 +- 0.000000015 Vs 17:00:43 First Field Integral, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000530 +- 0.000000015 Vs FI1 = 0.00105983 +- 0.00002963 Tm 17:00:43 Integrated Voltage Measurement... 17:00:44 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:00:51 Voltage Offset Correction: v_off_ini = -0.000001557 V, v_off_fin = -0.000001559 V 17:00:51 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000443 Vs 17:00:57 Voltage Offset Correction: v_off_ini = -0.000001482 V, v_off_fin = -0.000001463 V 17:00:57 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000521 Vs 17:00:58 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:01:04 Voltage Offset Correction: v_off_ini = -0.000001624 V, v_off_fin = -0.000002133 V 17:01:04 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000533 Vs 17:01:10 Voltage Offset Correction: v_off_ini = -0.000001664 V, v_off_fin = -0.000002106 V 17:01:10 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000513 Vs 17:01:11 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:01:17 Voltage Offset Correction: v_off_ini = -0.000001472 V, v_off_fin = -0.000001164 V 17:01:17 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000482 Vs 17:01:24 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000001597 V 17:01:24 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000515 Vs 17:01:24 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:01:30 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = -0.000001725 V 17:01:30 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000515 Vs 17:01:37 Voltage Offset Correction: v_off_ini = -0.000001532 V, v_off_fin = -0.000001263 V 17:01:37 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000513 Vs 17:01:37 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:01:44 Voltage Offset Correction: v_off_ini = -0.000001759 V, v_off_fin = -0.000001611 V 17:01:44 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000492 Vs 17:01:50 Voltage Offset Correction: v_off_ini = -0.000001724 V, v_off_fin = -0.000001654 V 17:01:50 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000532 Vs 17:01:51 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:01:57 Voltage Offset Correction: v_off_ini = -0.000001732 V, v_off_fin = -0.000001767 V 17:01:57 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000491 Vs 17:02:03 Voltage Offset Correction: v_off_ini = -0.000001561 V, v_off_fin = -0.000001310 V 17:02:03 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000542 Vs 17:02:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000508 +- 0.000000014 Vs 17:02:03 First Field Integral, Average and RMS of Measurements X0 = 0.0130000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000508 +- 0.000000014 Vs FI1 = 0.00101543 +- 0.00002731 Tm 17:02:03 Integrated Voltage Measurement... 17:02:04 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:02:11 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000001356 V 17:02:11 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000473 Vs 17:02:17 Voltage Offset Correction: v_off_ini = -0.000001531 V, v_off_fin = -0.000002086 V 17:02:17 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000475 Vs 17:02:18 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:02:24 Voltage Offset Correction: v_off_ini = -0.000001616 V, v_off_fin = -0.000001716 V 17:02:24 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000443 Vs 17:02:30 Voltage Offset Correction: v_off_ini = -0.000001747 V, v_off_fin = -0.000001579 V 17:02:30 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000470 Vs 17:02:31 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:02:37 Voltage Offset Correction: v_off_ini = -0.000001464 V, v_off_fin = -0.000001619 V 17:02:37 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000445 Vs 17:02:43 Voltage Offset Correction: v_off_ini = -0.000001618 V, v_off_fin = -0.000001485 V 17:02:43 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000449 Vs 17:02:44 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:02:50 Voltage Offset Correction: v_off_ini = -0.000001567 V, v_off_fin = -0.000001628 V 17:02:50 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000475 Vs 17:02:56 Voltage Offset Correction: v_off_ini = -0.000001484 V, v_off_fin = -0.000001280 V 17:02:56 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000437 Vs 17:02:57 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:03:03 Voltage Offset Correction: v_off_ini = -0.000001683 V, v_off_fin = -0.000001729 V 17:03:03 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000454 Vs 17:03:10 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000001582 V 17:03:10 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000479 Vs 17:03:10 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:03:17 Voltage Offset Correction: v_off_ini = -0.000001711 V, v_off_fin = -0.000001758 V 17:03:17 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000465 Vs 17:03:23 Voltage Offset Correction: v_off_ini = -0.000001468 V, v_off_fin = -0.000001676 V 17:03:23 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000461 Vs 17:03:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000460 +- 0.000000009 Vs 17:03:23 First Field Integral, Average and RMS of Measurements X0 = 0.0135000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000460 +- 0.000000009 Vs FI1 = 0.00092100 +- 0.00001706 Tm 17:03:23 Integrated Voltage Measurement... 17:03:24 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:03:31 Voltage Offset Correction: v_off_ini = -0.000001891 V, v_off_fin = -0.000001918 V 17:03:31 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000388 Vs 17:03:37 Voltage Offset Correction: v_off_ini = -0.000001653 V, v_off_fin = -0.000001421 V 17:03:37 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000450 Vs 17:03:38 Magnet Current for B9V2, Imag = 233.0999 A Vtrans = 2.330990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:03:44 Voltage Offset Correction: v_off_ini = -0.000001514 V, v_off_fin = -0.000001439 V 17:03:44 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000402 Vs 17:03:50 Voltage Offset Correction: v_off_ini = -0.000001612 V, v_off_fin = -0.000001471 V 17:03:50 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000415 Vs 17:03:51 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:03:57 Voltage Offset Correction: v_off_ini = -0.000001724 V, v_off_fin = -0.000001632 V 17:03:57 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000362 Vs 17:04:03 Voltage Offset Correction: v_off_ini = -0.000001656 V, v_off_fin = -0.000001808 V 17:04:03 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000383 Vs 17:04:04 Magnet Current for B9V2, Imag = 233.0998 A Vtrans = 2.330988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:04:10 Voltage Offset Correction: v_off_ini = -0.000001832 V, v_off_fin = -0.000001993 V 17:04:10 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000434 Vs 17:04:16 Voltage Offset Correction: v_off_ini = -0.000001598 V, v_off_fin = -0.000001684 V 17:04:16 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000440 Vs 17:04:17 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:04:23 Voltage Offset Correction: v_off_ini = -0.000001628 V, v_off_fin = -0.000001692 V 17:04:23 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000418 Vs 17:04:29 Voltage Offset Correction: v_off_ini = -0.000001410 V, v_off_fin = -0.000001529 V 17:04:29 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000427 Vs 17:04:30 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:04:36 Voltage Offset Correction: v_off_ini = -0.000001613 V, v_off_fin = -0.000001730 V 17:04:36 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000398 Vs 17:04:43 Voltage Offset Correction: v_off_ini = -0.000001606 V, v_off_fin = -0.000001522 V 17:04:43 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000407 Vs 17:04:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000410 +- 0.000000020 Vs 17:04:43 First Field Integral, Average and RMS of Measurements X0 = 0.0140000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000410 +- 0.000000020 Vs FI1 = 0.00082054 +- 0.00004032 Tm 17:04:47 Position moved: 0.000000 m 17:04:48 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:04:48 ‰” Voltage Measurement, V = 0.000000 V 17:04:48 Magnet Test Parameter Measurements P0 = B9V2, Value = 233.10 17:04:48 Integrated Voltage Measurement... 17:04:49 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:04:56 Voltage Offset Correction: v_off_ini = -0.000001556 V, v_off_fin = -0.000001712 V 17:04:56 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000491 Vs 17:05:03 Voltage Offset Correction: v_off_ini = -0.000001605 V, v_off_fin = -0.000001523 V 17:05:03 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000540 Vs 17:05:03 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:05:10 Voltage Offset Correction: v_off_ini = -0.000001573 V, v_off_fin = -0.000001668 V 17:05:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000499 Vs 17:05:16 Voltage Offset Correction: v_off_ini = -0.000001690 V, v_off_fin = -0.000001603 V 17:05:16 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000517 Vs 17:05:17 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:05:23 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000001494 V 17:05:23 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000494 Vs 17:05:29 Voltage Offset Correction: v_off_ini = -0.000001551 V, v_off_fin = -0.000001542 V 17:05:29 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 17:05:30 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:05:36 Voltage Offset Correction: v_off_ini = -0.000001657 V, v_off_fin = -0.000001725 V 17:05:36 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000522 Vs 17:05:42 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000001402 V 17:05:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 17:05:43 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:05:49 Voltage Offset Correction: v_off_ini = -0.000001343 V, v_off_fin = -0.000001448 V 17:05:49 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 17:05:55 Voltage Offset Correction: v_off_ini = -0.000001430 V, v_off_fin = -0.000001469 V 17:05:55 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000502 Vs 17:05:56 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:06:02 Voltage Offset Correction: v_off_ini = -0.000001578 V, v_off_fin = -0.000002027 V 17:06:02 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000572 Vs 17:06:09 Voltage Offset Correction: v_off_ini = -0.000001569 V, v_off_fin = -0.000001597 V 17:06:09 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000518 Vs 17:06:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000518 +- 0.000000014 Vs 17:06:09 First Field Integral, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000518 +- 0.000000014 Vs FI1 = 0.00103514 +- 0.00002708 Tm 17:06:09 Integrated Voltage Measurement... 17:06:09 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:06:17 Voltage Offset Correction: v_off_ini = -0.000001532 V, v_off_fin = -0.000001721 V 17:06:17 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000571 Vs 17:06:23 Voltage Offset Correction: v_off_ini = -0.000001568 V, v_off_fin = -0.000001888 V 17:06:23 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000587 Vs 17:06:24 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:06:30 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000001548 V 17:06:30 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000538 Vs 17:06:36 Voltage Offset Correction: v_off_ini = -0.000001454 V, v_off_fin = -0.000001405 V 17:06:36 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000519 Vs 17:06:37 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:06:43 Voltage Offset Correction: v_off_ini = -0.000001619 V, v_off_fin = -0.000001747 V 17:06:43 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000538 Vs 17:06:49 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000001392 V 17:06:49 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000535 Vs 17:06:50 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:06:56 Voltage Offset Correction: v_off_ini = -0.000001635 V, v_off_fin = -0.000001622 V 17:06:56 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000506 Vs 17:07:02 Voltage Offset Correction: v_off_ini = -0.000001755 V, v_off_fin = -0.000001613 V 17:07:02 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 17:07:03 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:07:09 Voltage Offset Correction: v_off_ini = -0.000001560 V, v_off_fin = -0.000001151 V 17:07:09 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000537 Vs 17:07:15 Voltage Offset Correction: v_off_ini = -0.000001664 V, v_off_fin = -0.000001724 V 17:07:15 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000530 Vs 17:07:16 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:07:22 Voltage Offset Correction: v_off_ini = -0.000001435 V, v_off_fin = -0.000001539 V 17:07:22 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 17:07:28 Voltage Offset Correction: v_off_ini = -0.000001578 V, v_off_fin = -0.000001548 V 17:07:28 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000554 Vs 17:07:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000539 +- 0.000000018 Vs 17:07:28 First Field Integral, Average and RMS of Measurements X0 = 0.0055000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000539 +- 0.000000018 Vs FI1 = 0.00107830 +- 0.00003647 Tm 17:07:29 Integrated Voltage Measurement... 17:07:29 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:07:37 Voltage Offset Correction: v_off_ini = -0.000001596 V, v_off_fin = -0.000001611 V 17:07:37 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000530 Vs 17:07:43 Voltage Offset Correction: v_off_ini = -0.000001627 V, v_off_fin = -0.000001634 V 17:07:43 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000520 Vs 17:07:43 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:07:50 Voltage Offset Correction: v_off_ini = -0.000001731 V, v_off_fin = -0.000001788 V 17:07:50 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 17:07:56 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000001423 V 17:07:56 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000536 Vs 17:07:57 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:08:03 Voltage Offset Correction: v_off_ini = -0.000001594 V, v_off_fin = -0.000001632 V 17:08:03 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000511 Vs 17:08:09 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000001434 V 17:08:09 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000547 Vs 17:08:10 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:08:15 Voltage Offset Correction: v_off_ini = -0.000001599 V, v_off_fin = -0.000001065 V 17:08:15 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000555 Vs 17:08:21 Voltage Offset Correction: v_off_ini = -0.000001585 V, v_off_fin = -0.000001444 V 17:08:21 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000538 Vs 17:08:22 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:08:28 Voltage Offset Correction: v_off_ini = -0.000001734 V, v_off_fin = -0.000001911 V 17:08:28 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000521 Vs 17:08:34 Voltage Offset Correction: v_off_ini = -0.000001581 V, v_off_fin = -0.000001628 V 17:08:34 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000487 Vs 17:08:35 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:08:41 Voltage Offset Correction: v_off_ini = -0.000001543 V, v_off_fin = -0.000001444 V 17:08:41 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000522 Vs 17:08:47 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = -0.000001775 V 17:08:47 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000513 Vs 17:08:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000527 +- 0.000000014 Vs 17:08:48 First Field Integral, Average and RMS of Measurements X0 = 0.0060000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000527 +- 0.000000014 Vs FI1 = 0.00105443 +- 0.00002887 Tm 17:08:48 Integrated Voltage Measurement... 17:08:48 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:08:56 Voltage Offset Correction: v_off_ini = -0.000001635 V, v_off_fin = -0.000001674 V 17:08:56 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000535 Vs 17:09:02 Voltage Offset Correction: v_off_ini = -0.000001518 V, v_off_fin = -0.000001486 V 17:09:02 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000498 Vs 17:09:03 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:09:09 Voltage Offset Correction: v_off_ini = -0.000001707 V, v_off_fin = -0.000001464 V 17:09:09 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000589 Vs 17:09:15 Voltage Offset Correction: v_off_ini = -0.000001475 V, v_off_fin = -0.000001683 V 17:09:15 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000498 Vs 17:09:16 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:09:22 Voltage Offset Correction: v_off_ini = -0.000001585 V, v_off_fin = -0.000001732 V 17:09:22 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000527 Vs 17:09:28 Voltage Offset Correction: v_off_ini = -0.000001761 V, v_off_fin = -0.000001821 V 17:09:28 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000512 Vs 17:09:29 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:09:35 Voltage Offset Correction: v_off_ini = -0.000001486 V, v_off_fin = -0.000001297 V 17:09:35 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000513 Vs 17:09:41 Voltage Offset Correction: v_off_ini = -0.000001713 V, v_off_fin = -0.000003122 V 17:09:41 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000500 Vs 17:09:42 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:09:48 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000001630 V 17:09:48 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000499 Vs 17:09:54 Voltage Offset Correction: v_off_ini = -0.000001579 V, v_off_fin = -0.000001445 V 17:09:54 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000537 Vs 17:09:55 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:10:01 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000001693 V 17:10:01 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000518 Vs 17:10:08 Voltage Offset Correction: v_off_ini = -0.000001693 V, v_off_fin = -0.000001486 V 17:10:08 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000530 Vs 17:10:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000521 +- 0.000000011 Vs 17:10:08 First Field Integral, Average and RMS of Measurements X0 = 0.0065000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000521 +- 0.000000011 Vs FI1 = 0.00104262 +- 0.00002230 Tm 17:10:08 Integrated Voltage Measurement... 17:10:08 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:10:16 Voltage Offset Correction: v_off_ini = -0.000001815 V, v_off_fin = -0.000001864 V 17:10:16 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000521 Vs 17:10:22 Voltage Offset Correction: v_off_ini = -0.000001643 V, v_off_fin = -0.000001549 V 17:10:22 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000516 Vs 17:10:23 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:10:29 Voltage Offset Correction: v_off_ini = -0.000001480 V, v_off_fin = -0.000001497 V 17:10:29 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000521 Vs 17:10:35 Voltage Offset Correction: v_off_ini = -0.000001671 V, v_off_fin = -0.000001886 V 17:10:35 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 17:10:36 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:10:42 Voltage Offset Correction: v_off_ini = -0.000001970 V, v_off_fin = -0.000002128 V 17:10:42 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000545 Vs 17:10:48 Voltage Offset Correction: v_off_ini = -0.000001623 V, v_off_fin = -0.000001569 V 17:10:48 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000510 Vs 17:10:49 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:10:55 Voltage Offset Correction: v_off_ini = -0.000001660 V, v_off_fin = -0.000001757 V 17:10:55 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000535 Vs 17:11:01 Voltage Offset Correction: v_off_ini = -0.000001538 V, v_off_fin = -0.000001679 V 17:11:01 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000550 Vs 17:11:02 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:11:08 Voltage Offset Correction: v_off_ini = -0.000001685 V, v_off_fin = -0.000001872 V 17:11:08 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000516 Vs 17:11:14 Voltage Offset Correction: v_off_ini = -0.000001796 V, v_off_fin = -0.000001592 V 17:11:14 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000532 Vs 17:11:15 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:11:21 Voltage Offset Correction: v_off_ini = -0.000001494 V, v_off_fin = -0.000001600 V 17:11:21 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 17:11:28 Voltage Offset Correction: v_off_ini = -0.000001644 V, v_off_fin = -0.000001503 V 17:11:28 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000561 Vs 17:11:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000531 +- 0.000000008 Vs 17:11:28 First Field Integral, Average and RMS of Measurements X0 = 0.0070000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000531 +- 0.000000008 Vs FI1 = 0.00106205 +- 0.00001690 Tm 17:11:28 Integrated Voltage Measurement... 17:11:28 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:11:36 Voltage Offset Correction: v_off_ini = -0.000001601 V, v_off_fin = -0.000001569 V 17:11:36 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000540 Vs 17:11:42 Voltage Offset Correction: v_off_ini = -0.000001509 V, v_off_fin = -0.000001503 V 17:11:42 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000556 Vs 17:11:43 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:11:49 Voltage Offset Correction: v_off_ini = -0.000001523 V, v_off_fin = -0.000000969 V 17:11:49 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000600 Vs 17:11:55 Voltage Offset Correction: v_off_ini = -0.000001483 V, v_off_fin = -0.000001495 V 17:11:55 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 17:11:56 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:12:02 Voltage Offset Correction: v_off_ini = -0.000001406 V, v_off_fin = -0.000001449 V 17:12:02 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:12:08 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = -0.000001403 V 17:12:08 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000568 Vs 17:12:09 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:12:15 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000001655 V 17:12:15 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000540 Vs 17:12:21 Voltage Offset Correction: v_off_ini = -0.000001569 V, v_off_fin = -0.000001330 V 17:12:21 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000575 Vs 17:12:22 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:12:28 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000001661 V 17:12:28 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000533 Vs 17:12:34 Voltage Offset Correction: v_off_ini = -0.000001403 V, v_off_fin = -0.000001256 V 17:12:34 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000563 Vs 17:12:35 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:12:41 Voltage Offset Correction: v_off_ini = -0.000001630 V, v_off_fin = -0.000001482 V 17:12:41 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 17:12:47 Voltage Offset Correction: v_off_ini = -0.000001521 V, v_off_fin = -0.000001245 V 17:12:47 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 17:12:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000554 +- 0.000000012 Vs 17:12:47 First Field Integral, Average and RMS of Measurements X0 = 0.0075000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000554 +- 0.000000012 Vs FI1 = 0.00110718 +- 0.00002448 Tm 17:12:48 Integrated Voltage Measurement... 17:12:48 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:12:56 Voltage Offset Correction: v_off_ini = -0.000001499 V, v_off_fin = -0.000001429 V 17:12:56 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000521 Vs 17:13:02 Voltage Offset Correction: v_off_ini = -0.000001545 V, v_off_fin = -0.000001400 V 17:13:02 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000529 Vs 17:13:02 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:13:09 Voltage Offset Correction: v_off_ini = -0.000001572 V, v_off_fin = -0.000001562 V 17:13:09 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000561 Vs 17:13:15 Voltage Offset Correction: v_off_ini = -0.000001869 V, v_off_fin = -0.000001976 V 17:13:15 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000537 Vs 17:13:16 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:13:22 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000001847 V 17:13:22 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000551 Vs 17:13:28 Voltage Offset Correction: v_off_ini = -0.000001572 V, v_off_fin = -0.000001451 V 17:13:28 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000540 Vs 17:13:29 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:13:35 Voltage Offset Correction: v_off_ini = -0.000001600 V, v_off_fin = -0.000001690 V 17:13:35 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000503 Vs 17:13:41 Voltage Offset Correction: v_off_ini = -0.000001523 V, v_off_fin = -0.000001580 V 17:13:41 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000553 Vs 17:13:42 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:13:48 Voltage Offset Correction: v_off_ini = -0.000001605 V, v_off_fin = -0.000001688 V 17:13:48 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000476 Vs 17:13:54 Voltage Offset Correction: v_off_ini = -0.000001625 V, v_off_fin = -0.000001536 V 17:13:54 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000553 Vs 17:13:55 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:14:01 Voltage Offset Correction: v_off_ini = -0.000001706 V, v_off_fin = -0.000001782 V 17:14:01 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000572 Vs 17:14:07 Voltage Offset Correction: v_off_ini = -0.000001771 V, v_off_fin = -0.000001579 V 17:14:07 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000535 Vs 17:14:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000536 +- 0.000000014 Vs 17:14:07 First Field Integral, Average and RMS of Measurements X0 = 0.0080000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000536 +- 0.000000014 Vs FI1 = 0.00107186 +- 0.00002850 Tm 17:14:08 Integrated Voltage Measurement... 17:14:08 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:14:15 Voltage Offset Correction: v_off_ini = -0.000001736 V, v_off_fin = -0.000001632 V 17:14:15 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000519 Vs 17:14:22 Voltage Offset Correction: v_off_ini = -0.000001557 V, v_off_fin = -0.000001492 V 17:14:22 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000549 Vs 17:14:22 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:14:29 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000001524 V 17:14:29 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000550 Vs 17:14:35 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000001738 V 17:14:35 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000623 Vs 17:14:35 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:14:42 Voltage Offset Correction: v_off_ini = -0.000001483 V, v_off_fin = -0.000001632 V 17:14:42 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000499 Vs 17:14:48 Voltage Offset Correction: v_off_ini = -0.000001600 V, v_off_fin = -0.000001392 V 17:14:48 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 17:14:49 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:14:55 Voltage Offset Correction: v_off_ini = -0.000001556 V, v_off_fin = -0.000001853 V 17:14:55 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000569 Vs 17:15:01 Voltage Offset Correction: v_off_ini = -0.000001545 V, v_off_fin = -0.000001661 V 17:15:01 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000518 Vs 17:15:02 Magnet Current for B9V2, Imag = 233.0998 A Vtrans = 2.330988 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:15:08 Voltage Offset Correction: v_off_ini = -0.000001637 V, v_off_fin = -0.000001628 V 17:15:08 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000526 Vs 17:15:14 Voltage Offset Correction: v_off_ini = -0.000001799 V, v_off_fin = -0.000001981 V 17:15:14 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000563 Vs 17:15:15 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:15:21 Voltage Offset Correction: v_off_ini = -0.000001520 V, v_off_fin = -0.000001441 V 17:15:21 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000546 Vs 17:15:27 Voltage Offset Correction: v_off_ini = -0.000001479 V, v_off_fin = -0.000001431 V 17:15:27 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000539 Vs 17:15:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000547 +- 0.000000019 Vs 17:15:27 First Field Integral, Average and RMS of Measurements X0 = 0.0085000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000547 +- 0.000000019 Vs FI1 = 0.00109321 +- 0.00003769 Tm 17:15:27 Integrated Voltage Measurement... 17:15:28 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:15:35 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000001414 V 17:15:35 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000534 Vs 17:15:41 Voltage Offset Correction: v_off_ini = -0.000001759 V, v_off_fin = -0.000001919 V 17:15:41 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000552 Vs 17:15:42 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:15:48 Voltage Offset Correction: v_off_ini = -0.000001577 V, v_off_fin = -0.000001719 V 17:15:48 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000558 Vs 17:15:54 Voltage Offset Correction: v_off_ini = -0.000001427 V, v_off_fin = -0.000001368 V 17:15:54 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000551 Vs 17:15:55 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:16:01 Voltage Offset Correction: v_off_ini = -0.000001561 V, v_off_fin = -0.000001497 V 17:16:01 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 17:16:08 Voltage Offset Correction: v_off_ini = -0.000001753 V, v_off_fin = -0.000001935 V 17:16:08 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000535 Vs 17:16:08 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:16:14 Voltage Offset Correction: v_off_ini = -0.000001582 V, v_off_fin = -0.000001128 V 17:16:14 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000545 Vs 17:16:21 Voltage Offset Correction: v_off_ini = -0.000001743 V, v_off_fin = -0.000001845 V 17:16:21 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000510 Vs 17:16:21 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:16:28 Voltage Offset Correction: v_off_ini = -0.000001601 V, v_off_fin = -0.000001592 V 17:16:28 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000518 Vs 17:16:34 Voltage Offset Correction: v_off_ini = -0.000001384 V, v_off_fin = -0.000001394 V 17:16:34 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000559 Vs 17:16:34 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:16:41 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000001158 V 17:16:41 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000464 Vs 17:16:47 Voltage Offset Correction: v_off_ini = -0.000001513 V, v_off_fin = -0.000001515 V 17:16:47 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 17:16:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000535 +- 0.000000016 Vs 17:16:47 First Field Integral, Average and RMS of Measurements X0 = 0.0090000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000535 +- 0.000000016 Vs FI1 = 0.00106980 +- 0.00003143 Tm 17:16:47 Integrated Voltage Measurement... 17:16:48 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:16:55 Voltage Offset Correction: v_off_ini = -0.000001519 V, v_off_fin = -0.000001497 V 17:16:55 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000520 Vs 17:17:01 Voltage Offset Correction: v_off_ini = -0.000001688 V, v_off_fin = -0.000001719 V 17:17:01 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000547 Vs 17:17:02 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:17:08 Voltage Offset Correction: v_off_ini = -0.000001506 V, v_off_fin = -0.000001470 V 17:17:08 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000545 Vs 17:17:14 Voltage Offset Correction: v_off_ini = -0.000001568 V, v_off_fin = -0.000001562 V 17:17:14 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000567 Vs 17:17:15 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:17:21 Voltage Offset Correction: v_off_ini = -0.000001518 V, v_off_fin = -0.000001623 V 17:17:21 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000561 Vs 17:17:27 Voltage Offset Correction: v_off_ini = -0.000001469 V, v_off_fin = -0.000001882 V 17:17:28 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000543 Vs 17:17:28 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:17:35 Voltage Offset Correction: v_off_ini = -0.000001616 V, v_off_fin = -0.000001525 V 17:17:35 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000549 Vs 17:17:41 Voltage Offset Correction: v_off_ini = -0.000001718 V, v_off_fin = -0.000001566 V 17:17:41 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000566 Vs 17:17:42 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:17:48 Voltage Offset Correction: v_off_ini = -0.000001550 V, v_off_fin = -0.000001565 V 17:17:48 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000518 Vs 17:17:54 Voltage Offset Correction: v_off_ini = -0.000001591 V, v_off_fin = -0.000001506 V 17:17:54 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000584 Vs 17:17:55 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:18:01 Voltage Offset Correction: v_off_ini = -0.000001677 V, v_off_fin = -0.000001610 V 17:18:01 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000552 Vs 17:18:07 Voltage Offset Correction: v_off_ini = -0.000001480 V, v_off_fin = -0.000001487 V 17:18:07 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000598 Vs 17:18:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000554 +- 0.000000012 Vs 17:18:07 First Field Integral, Average and RMS of Measurements X0 = 0.0095000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000554 +- 0.000000012 Vs FI1 = 0.00110810 +- 0.00002459 Tm 17:18:07 Integrated Voltage Measurement... 17:18:08 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:18:15 Voltage Offset Correction: v_off_ini = -0.000001554 V, v_off_fin = -0.000001836 V 17:18:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000512 Vs 17:18:21 Voltage Offset Correction: v_off_ini = -0.000001479 V, v_off_fin = -0.000001529 V 17:18:21 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000533 Vs 17:18:22 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:18:28 Voltage Offset Correction: v_off_ini = -0.000001457 V, v_off_fin = -0.000001332 V 17:18:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000512 Vs 17:18:35 Voltage Offset Correction: v_off_ini = -0.000001431 V, v_off_fin = -0.000001520 V 17:18:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000567 Vs 17:18:35 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:18:41 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000001502 V 17:18:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000588 Vs 17:18:48 Voltage Offset Correction: v_off_ini = -0.000001672 V, v_off_fin = -0.000001778 V 17:18:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000568 Vs 17:18:48 Magnet Current for B9V2, Imag = 233.1001 A Vtrans = 2.330991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:18:55 Voltage Offset Correction: v_off_ini = -0.000001608 V, v_off_fin = -0.000001558 V 17:18:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000507 Vs 17:19:01 Voltage Offset Correction: v_off_ini = -0.000001508 V, v_off_fin = -0.000001459 V 17:19:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000583 Vs 17:19:02 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:19:08 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000001455 V 17:19:08 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000564 Vs 17:19:14 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = -0.000001723 V 17:19:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 17:19:15 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:19:21 Voltage Offset Correction: v_off_ini = -0.000001576 V, v_off_fin = -0.000001583 V 17:19:21 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000568 Vs 17:19:27 Voltage Offset Correction: v_off_ini = -0.000001377 V, v_off_fin = -0.000001275 V 17:19:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000578 Vs 17:19:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000552 +- 0.000000019 Vs 17:19:27 First Field Integral, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000552 +- 0.000000019 Vs FI1 = 0.00110400 +- 0.00003813 Tm 17:19:27 Integrated Voltage Measurement... 17:19:28 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:19:35 Voltage Offset Correction: v_off_ini = -0.000001678 V, v_off_fin = -0.000001558 V 17:19:35 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 17:19:42 Voltage Offset Correction: v_off_ini = -0.000001606 V, v_off_fin = -0.000001641 V 17:19:42 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000551 Vs 17:19:42 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:19:48 Voltage Offset Correction: v_off_ini = -0.000001378 V, v_off_fin = -0.000001716 V 17:19:48 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000561 Vs 17:19:55 Voltage Offset Correction: v_off_ini = -0.000001415 V, v_off_fin = -0.000001634 V 17:19:55 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000579 Vs 17:19:55 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:20:02 Voltage Offset Correction: v_off_ini = -0.000001431 V, v_off_fin = -0.000001872 V 17:20:02 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000535 Vs 17:20:08 Voltage Offset Correction: v_off_ini = -0.000001638 V, v_off_fin = -0.000001297 V 17:20:08 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000553 Vs 17:20:09 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:20:15 Voltage Offset Correction: v_off_ini = -0.000001574 V, v_off_fin = -0.000001632 V 17:20:15 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000560 Vs 17:20:21 Voltage Offset Correction: v_off_ini = -0.000001478 V, v_off_fin = -0.000001688 V 17:20:21 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000556 Vs 17:20:22 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:20:28 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000001578 V 17:20:28 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000549 Vs 17:20:34 Voltage Offset Correction: v_off_ini = -0.000001628 V, v_off_fin = -0.000001480 V 17:20:34 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000561 Vs 17:20:35 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:20:41 Voltage Offset Correction: v_off_ini = -0.000001510 V, v_off_fin = -0.000001775 V 17:20:41 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000542 Vs 17:20:47 Voltage Offset Correction: v_off_ini = -0.000001480 V, v_off_fin = -0.000001230 V 17:20:47 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000560 Vs 17:20:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000553 +- 0.000000010 Vs 17:20:47 First Field Integral, Average and RMS of Measurements X0 = 0.0105000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000553 +- 0.000000010 Vs FI1 = 0.00110513 +- 0.00002067 Tm 17:20:47 Integrated Voltage Measurement... 17:20:48 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:20:55 Voltage Offset Correction: v_off_ini = -0.000001561 V, v_off_fin = -0.000001673 V 17:20:55 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000555 Vs 17:21:02 Voltage Offset Correction: v_off_ini = -0.000001542 V, v_off_fin = -0.000001600 V 17:21:02 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000542 Vs 17:21:02 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:21:09 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000001668 V 17:21:09 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000517 Vs 17:21:15 Voltage Offset Correction: v_off_ini = -0.000001473 V, v_off_fin = -0.000001612 V 17:21:15 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000569 Vs 17:21:15 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:21:22 Voltage Offset Correction: v_off_ini = -0.000001772 V, v_off_fin = -0.000001820 V 17:21:22 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 17:21:28 Voltage Offset Correction: v_off_ini = -0.000001666 V, v_off_fin = -0.000001791 V 17:21:28 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000562 Vs 17:21:29 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:21:35 Voltage Offset Correction: v_off_ini = -0.000001748 V, v_off_fin = -0.000001788 V 17:21:35 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000562 Vs 17:21:41 Voltage Offset Correction: v_off_ini = -0.000001619 V, v_off_fin = -0.000001492 V 17:21:41 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 17:21:42 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:21:48 Voltage Offset Correction: v_off_ini = -0.000001495 V, v_off_fin = -0.000001504 V 17:21:48 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 17:21:54 Voltage Offset Correction: v_off_ini = -0.000001535 V, v_off_fin = -0.000000596 V 17:21:54 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000567 Vs 17:21:55 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:22:01 Voltage Offset Correction: v_off_ini = -0.000001548 V, v_off_fin = -0.000001615 V 17:22:01 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000573 Vs 17:22:07 Voltage Offset Correction: v_off_ini = -0.000001719 V, v_off_fin = -0.000001547 V 17:22:07 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000578 Vs 17:22:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000554 +- 0.000000011 Vs 17:22:07 First Field Integral, Average and RMS of Measurements X0 = 0.0110000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000554 +- 0.000000011 Vs FI1 = 0.00110769 +- 0.00002247 Tm 17:22:07 Integrated Voltage Measurement... 17:22:08 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:22:15 Voltage Offset Correction: v_off_ini = -0.000001788 V, v_off_fin = -0.000001907 V 17:22:15 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000554 Vs 17:22:22 Voltage Offset Correction: v_off_ini = -0.000001494 V, v_off_fin = -0.000001477 V 17:22:22 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000567 Vs 17:22:22 Magnet Current for B9V2, Imag = 233.1002 A Vtrans = 2.330992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:22:29 Voltage Offset Correction: v_off_ini = -0.000001406 V, v_off_fin = -0.000001116 V 17:22:29 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000542 Vs 17:22:35 Voltage Offset Correction: v_off_ini = -0.000001592 V, v_off_fin = -0.000001523 V 17:22:35 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000575 Vs 17:22:36 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:22:42 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = -0.000001525 V 17:22:42 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000562 Vs 17:22:48 Voltage Offset Correction: v_off_ini = -0.000001579 V, v_off_fin = -0.000001418 V 17:22:48 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000573 Vs 17:22:49 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:22:55 Voltage Offset Correction: v_off_ini = -0.000001523 V, v_off_fin = -0.000001714 V 17:22:55 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000522 Vs 17:23:01 Voltage Offset Correction: v_off_ini = -0.000001461 V, v_off_fin = -0.000001110 V 17:23:01 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000558 Vs 17:23:02 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:23:08 Voltage Offset Correction: v_off_ini = -0.000001594 V, v_off_fin = -0.000001521 V 17:23:08 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000559 Vs 17:23:14 Voltage Offset Correction: v_off_ini = -0.000001555 V, v_off_fin = -0.000001508 V 17:23:14 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000568 Vs 17:23:15 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:23:21 Voltage Offset Correction: v_off_ini = -0.000001638 V, v_off_fin = -0.000001845 V 17:23:21 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 17:23:27 Voltage Offset Correction: v_off_ini = -0.000001570 V, v_off_fin = -0.000001556 V 17:23:27 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000558 Vs 17:23:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000557 +- 0.000000009 Vs 17:23:27 First Field Integral, Average and RMS of Measurements X0 = 0.0115000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000557 +- 0.000000009 Vs FI1 = 0.00111428 +- 0.00001766 Tm 17:23:28 Integrated Voltage Measurement... 17:23:28 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:23:36 Voltage Offset Correction: v_off_ini = -0.000001480 V, v_off_fin = -0.000001642 V 17:23:36 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000526 Vs 17:23:42 Voltage Offset Correction: v_off_ini = -0.000001557 V, v_off_fin = -0.000001531 V 17:23:42 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000581 Vs 17:23:42 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:23:49 Voltage Offset Correction: v_off_ini = -0.000001525 V, v_off_fin = -0.000001511 V 17:23:49 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000527 Vs 17:23:55 Voltage Offset Correction: v_off_ini = -0.000001593 V, v_off_fin = -0.000001591 V 17:23:55 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000570 Vs 17:23:56 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:24:02 Voltage Offset Correction: v_off_ini = -0.000001592 V, v_off_fin = -0.000001667 V 17:24:02 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000553 Vs 17:24:08 Voltage Offset Correction: v_off_ini = -0.000001534 V, v_off_fin = -0.000001551 V 17:24:08 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000549 Vs 17:24:09 Magnet Current for B9V2, Imag = 233.1004 A Vtrans = 2.330995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:24:15 Voltage Offset Correction: v_off_ini = -0.000001421 V, v_off_fin = -0.000001236 V 17:24:15 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000566 Vs 17:24:21 Voltage Offset Correction: v_off_ini = -0.000001791 V, v_off_fin = -0.000001753 V 17:24:21 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000550 Vs 17:24:22 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:24:28 Voltage Offset Correction: v_off_ini = -0.000001732 V, v_off_fin = -0.000001808 V 17:24:28 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000556 Vs 17:24:34 Voltage Offset Correction: v_off_ini = -0.000001632 V, v_off_fin = -0.000001859 V 17:24:34 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000595 Vs 17:24:35 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:24:41 Voltage Offset Correction: v_off_ini = -0.000001611 V, v_off_fin = -0.000001628 V 17:24:41 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000540 Vs 17:24:47 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = -0.000001569 V 17:24:47 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000561 Vs 17:24:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000556 +- 0.000000009 Vs 17:24:48 First Field Integral, Average and RMS of Measurements X0 = 0.0120000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000556 +- 0.000000009 Vs FI1 = 0.00111226 +- 0.00001845 Tm 17:24:48 Integrated Voltage Measurement... 17:24:48 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:24:56 Voltage Offset Correction: v_off_ini = -0.000001775 V, v_off_fin = -0.000001565 V 17:24:56 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000489 Vs 17:25:02 Voltage Offset Correction: v_off_ini = -0.000001594 V, v_off_fin = -0.000001643 V 17:25:02 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000522 Vs 17:25:03 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:25:09 Voltage Offset Correction: v_off_ini = -0.000001568 V, v_off_fin = -0.000001629 V 17:25:09 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 17:25:15 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000001830 V 17:25:15 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000514 Vs 17:25:16 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:25:22 Voltage Offset Correction: v_off_ini = -0.000001421 V, v_off_fin = -0.000001501 V 17:25:22 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000544 Vs 17:25:28 Voltage Offset Correction: v_off_ini = -0.000001713 V, v_off_fin = -0.000001655 V 17:25:28 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000490 Vs 17:25:29 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:25:35 Voltage Offset Correction: v_off_ini = -0.000001778 V, v_off_fin = -0.000001556 V 17:25:35 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000530 Vs 17:25:41 Voltage Offset Correction: v_off_ini = -0.000001561 V, v_off_fin = -0.000001511 V 17:25:41 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000531 Vs 17:25:42 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:25:48 Voltage Offset Correction: v_off_ini = -0.000001592 V, v_off_fin = -0.000001412 V 17:25:48 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000537 Vs 17:25:54 Voltage Offset Correction: v_off_ini = -0.000001701 V, v_off_fin = -0.000001595 V 17:25:55 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000522 Vs 17:25:55 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:26:01 Voltage Offset Correction: v_off_ini = -0.000001808 V, v_off_fin = -0.000001868 V 17:26:01 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000545 Vs 17:26:08 Voltage Offset Correction: v_off_ini = -0.000001665 V, v_off_fin = -0.000001744 V 17:26:08 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 17:26:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000524 +- 0.000000013 Vs 17:26:08 First Field Integral, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000524 +- 0.000000013 Vs FI1 = 0.00104878 +- 0.00002513 Tm 17:26:08 Integrated Voltage Measurement... 17:26:09 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:26:16 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = -0.000001561 V 17:26:16 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 17:26:22 Voltage Offset Correction: v_off_ini = -0.000001630 V, v_off_fin = -0.000001727 V 17:26:22 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000484 Vs 17:26:23 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:26:29 Voltage Offset Correction: v_off_ini = -0.000001956 V, v_off_fin = -0.000002012 V 17:26:29 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000478 Vs 17:26:35 Voltage Offset Correction: v_off_ini = -0.000001508 V, v_off_fin = -0.000001597 V 17:26:35 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000507 Vs 17:26:36 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:26:42 Voltage Offset Correction: v_off_ini = -0.000001696 V, v_off_fin = -0.000001409 V 17:26:42 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000543 Vs 17:26:49 Voltage Offset Correction: v_off_ini = -0.000001769 V, v_off_fin = -0.000001893 V 17:26:49 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 17:26:49 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:26:56 Voltage Offset Correction: v_off_ini = -0.000001781 V, v_off_fin = -0.000001803 V 17:26:56 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000479 Vs 17:27:02 Voltage Offset Correction: v_off_ini = -0.000001563 V, v_off_fin = -0.000001473 V 17:27:02 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000465 Vs 17:27:03 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:27:09 Voltage Offset Correction: v_off_ini = -0.000001761 V, v_off_fin = -0.000001649 V 17:27:09 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000475 Vs 17:27:15 Voltage Offset Correction: v_off_ini = -0.000001256 V, v_off_fin = -0.000001292 V 17:27:15 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000439 Vs 17:27:16 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:27:22 Voltage Offset Correction: v_off_ini = -0.000001777 V, v_off_fin = -0.000001727 V 17:27:22 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000484 Vs 17:27:28 Voltage Offset Correction: v_off_ini = -0.000001731 V, v_off_fin = -0.000001851 V 17:27:28 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000498 Vs 17:27:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000490 +- 0.000000023 Vs 17:27:28 First Field Integral, Average and RMS of Measurements X0 = 0.0130000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000490 +- 0.000000023 Vs FI1 = 0.00098078 +- 0.00004698 Tm 17:27:28 Integrated Voltage Measurement... 17:27:29 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:27:36 Voltage Offset Correction: v_off_ini = -0.000001694 V, v_off_fin = -0.000001940 V 17:27:36 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000469 Vs 17:27:43 Voltage Offset Correction: v_off_ini = -0.000001763 V, v_off_fin = -0.000001494 V 17:27:43 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000478 Vs 17:27:43 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:27:50 Voltage Offset Correction: v_off_ini = -0.000001607 V, v_off_fin = -0.000001875 V 17:27:50 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000462 Vs 17:27:56 Voltage Offset Correction: v_off_ini = -0.000001462 V, v_off_fin = -0.000001365 V 17:27:56 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000489 Vs 17:27:57 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:28:03 Voltage Offset Correction: v_off_ini = -0.000001587 V, v_off_fin = -0.000001485 V 17:28:03 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000462 Vs 17:28:09 Voltage Offset Correction: v_off_ini = -0.000001669 V, v_off_fin = -0.000002096 V 17:28:09 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000426 Vs 17:28:10 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:28:16 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000001779 V 17:28:16 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000472 Vs 17:28:22 Voltage Offset Correction: v_off_ini = -0.000001829 V, v_off_fin = -0.000002194 V 17:28:22 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000554 Vs 17:28:23 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:28:29 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = -0.000001500 V 17:28:29 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000449 Vs 17:28:35 Voltage Offset Correction: v_off_ini = -0.000001682 V, v_off_fin = -0.000001642 V 17:28:35 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000518 Vs 17:28:36 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:28:42 Voltage Offset Correction: v_off_ini = -0.000001683 V, v_off_fin = -0.000001628 V 17:28:42 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000472 Vs 17:28:49 Voltage Offset Correction: v_off_ini = -0.000001642 V, v_off_fin = -0.000001775 V 17:28:49 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000479 Vs 17:28:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000477 +- 0.000000020 Vs 17:28:49 First Field Integral, Average and RMS of Measurements X0 = 0.0135000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000477 +- 0.000000020 Vs FI1 = 0.00095493 +- 0.00004019 Tm 17:28:49 Integrated Voltage Measurement... 17:28:49 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:28:57 Voltage Offset Correction: v_off_ini = -0.000001533 V, v_off_fin = -0.000001733 V 17:28:57 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000341 Vs 17:29:03 Voltage Offset Correction: v_off_ini = -0.000001528 V, v_off_fin = -0.000001402 V 17:29:03 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000363 Vs 17:29:04 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:29:10 Voltage Offset Correction: v_off_ini = -0.000001567 V, v_off_fin = -0.000001534 V 17:29:10 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000412 Vs 17:29:16 Voltage Offset Correction: v_off_ini = -0.000001653 V, v_off_fin = -0.000001470 V 17:29:16 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000462 Vs 17:29:17 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:29:23 Voltage Offset Correction: v_off_ini = -0.000001640 V, v_off_fin = -0.000001721 V 17:29:23 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000423 Vs 17:29:29 Voltage Offset Correction: v_off_ini = -0.000001783 V, v_off_fin = -0.000001905 V 17:29:29 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000396 Vs 17:29:30 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:29:36 Voltage Offset Correction: v_off_ini = -0.000001442 V, v_off_fin = -0.000001265 V 17:29:36 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000377 Vs 17:29:42 Voltage Offset Correction: v_off_ini = -0.000001562 V, v_off_fin = -0.000001410 V 17:29:42 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000471 Vs 17:29:43 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:29:49 Voltage Offset Correction: v_off_ini = -0.000001729 V, v_off_fin = -0.000001505 V 17:29:49 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000415 Vs 17:29:56 Voltage Offset Correction: v_off_ini = -0.000001504 V, v_off_fin = -0.000001633 V 17:29:56 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000431 Vs 17:29:56 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:30:03 Voltage Offset Correction: v_off_ini = -0.000001556 V, v_off_fin = -0.000001807 V 17:30:03 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000414 Vs 17:30:09 Voltage Offset Correction: v_off_ini = -0.000001492 V, v_off_fin = -0.000001355 V 17:30:09 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000430 Vs 17:30:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000411 +- 0.000000028 Vs 17:30:09 First Field Integral, Average and RMS of Measurements X0 = 0.0140000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000411 +- 0.000000028 Vs FI1 = 0.00082245 +- 0.00005560 Tm 17:30:14 Position moved: 0.000000 m 17:30:14 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:30:14 ‰” Voltage Measurement, V = 0.000000 V 17:30:14 Magnet Test Parameter Measurements P0 = B9V2, Value = 233.10 17:30:14 Integrated Voltage Measurement... 17:30:15 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:30:22 Voltage Offset Correction: v_off_ini = -0.000001390 V, v_off_fin = -0.000001522 V 17:30:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000481 Vs 17:30:29 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = -0.000001237 V 17:30:29 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000489 Vs 17:30:29 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:30:35 Voltage Offset Correction: v_off_ini = -0.000001628 V, v_off_fin = -0.000001755 V 17:30:36 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000528 Vs 17:30:42 Voltage Offset Correction: v_off_ini = -0.000001528 V, v_off_fin = -0.000001507 V 17:30:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000521 Vs 17:30:42 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:30:49 Voltage Offset Correction: v_off_ini = -0.000001516 V, v_off_fin = -0.000001544 V 17:30:49 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000505 Vs 17:30:55 Voltage Offset Correction: v_off_ini = -0.000000943 V, v_off_fin = -0.000000977 V 17:30:55 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000505 Vs 17:30:56 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:31:02 Voltage Offset Correction: v_off_ini = -0.000001401 V, v_off_fin = -0.000001218 V 17:31:02 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000503 Vs 17:31:08 Voltage Offset Correction: v_off_ini = -0.000001406 V, v_off_fin = -0.000001120 V 17:31:08 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000527 Vs 17:31:09 Magnet Current for B9V2, Imag = 233.1015 A Vtrans = 2.331005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:31:15 Voltage Offset Correction: v_off_ini = -0.000001425 V, v_off_fin = -0.000001273 V 17:31:15 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 17:31:21 Voltage Offset Correction: v_off_ini = -0.000001657 V, v_off_fin = -0.000001691 V 17:31:21 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000514 Vs 17:31:22 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:31:28 Voltage Offset Correction: v_off_ini = -0.000001499 V, v_off_fin = -0.000001509 V 17:31:28 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000508 Vs 17:31:34 Voltage Offset Correction: v_off_ini = -0.000001410 V, v_off_fin = -0.000001421 V 17:31:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0005000 m VT = -0.000000487 Vs 17:31:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0005000 m VT = 0.000000506 +- 0.000000013 Vs 17:31:34 First Field Integral, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000506 +- 0.000000013 Vs FI1 = 0.00101288 +- 0.00002531 Tm 17:31:34 Integrated Voltage Measurement... 17:31:35 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:31:42 Voltage Offset Correction: v_off_ini = -0.000001597 V, v_off_fin = -0.000001598 V 17:31:42 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000533 Vs 17:31:49 Voltage Offset Correction: v_off_ini = -0.000001420 V, v_off_fin = -0.000001318 V 17:31:49 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000537 Vs 17:31:49 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:31:55 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = -0.000001783 V 17:31:55 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000537 Vs 17:32:02 Voltage Offset Correction: v_off_ini = -0.000001482 V, v_off_fin = -0.000001484 V 17:32:02 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000540 Vs 17:32:02 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:32:09 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = -0.000001498 V 17:32:09 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 17:32:15 Voltage Offset Correction: v_off_ini = -0.000001325 V, v_off_fin = -0.000001304 V 17:32:15 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 17:32:16 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:32:22 Voltage Offset Correction: v_off_ini = -0.000001556 V, v_off_fin = -0.000001494 V 17:32:22 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000464 Vs 17:32:28 Voltage Offset Correction: v_off_ini = -0.000001455 V, v_off_fin = -0.000001325 V 17:32:28 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000535 Vs 17:32:29 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:32:35 Voltage Offset Correction: v_off_ini = -0.000001489 V, v_off_fin = -0.000001881 V 17:32:35 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000599 Vs 17:32:41 Voltage Offset Correction: v_off_ini = -0.000001477 V, v_off_fin = -0.000001289 V 17:32:41 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000531 Vs 17:32:42 Magnet Current for B9V2, Imag = 233.1003 A Vtrans = 2.330993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:32:48 Voltage Offset Correction: v_off_ini = -0.000001563 V, v_off_fin = -0.000001322 V 17:32:48 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000466 Vs 17:32:54 Voltage Offset Correction: v_off_ini = -0.000001800 V, v_off_fin = -0.000001763 V 17:32:54 Integrated Voltage Measurement X0 = 0.0055000 m, Delta X = -0.0005000 m VT = -0.000000511 Vs 17:32:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0055000 m, Delta X = 0.0005000 m VT = 0.000000524 +- 0.000000026 Vs 17:32:54 First Field Integral, Average and RMS of Measurements X0 = 0.0055000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000524 +- 0.000000026 Vs FI1 = 0.00104745 +- 0.00005126 Tm 17:32:55 Integrated Voltage Measurement... 17:32:55 Magnet Current for B9V2, Imag = 233.1017 A Vtrans = 2.331008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:33:03 Voltage Offset Correction: v_off_ini = -0.000001490 V, v_off_fin = -0.000001483 V 17:33:03 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 17:33:09 Voltage Offset Correction: v_off_ini = -0.000001519 V, v_off_fin = -0.000001394 V 17:33:09 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000556 Vs 17:33:10 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:33:16 Voltage Offset Correction: v_off_ini = -0.000001606 V, v_off_fin = -0.000001336 V 17:33:16 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 17:33:22 Voltage Offset Correction: v_off_ini = -0.000001601 V, v_off_fin = -0.000001548 V 17:33:22 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000504 Vs 17:33:23 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:33:29 Voltage Offset Correction: v_off_ini = -0.000001524 V, v_off_fin = -0.000001492 V 17:33:29 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000507 Vs 17:33:35 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = -0.000001901 V 17:33:35 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000536 Vs 17:33:36 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:33:42 Voltage Offset Correction: v_off_ini = -0.000001708 V, v_off_fin = -0.000001658 V 17:33:42 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000505 Vs 17:33:48 Voltage Offset Correction: v_off_ini = -0.000001586 V, v_off_fin = -0.000001306 V 17:33:48 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000540 Vs 17:33:49 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:33:55 Voltage Offset Correction: v_off_ini = -0.000001723 V, v_off_fin = -0.000001656 V 17:33:55 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000516 Vs 17:34:02 Voltage Offset Correction: v_off_ini = -0.000001532 V, v_off_fin = -0.000001938 V 17:34:02 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000624 Vs 17:34:02 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:34:09 Voltage Offset Correction: v_off_ini = -0.000001605 V, v_off_fin = -0.000001586 V 17:34:09 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000501 Vs 17:34:15 Voltage Offset Correction: v_off_ini = -0.000001349 V, v_off_fin = -0.000001284 V 17:34:15 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0005000 m VT = -0.000000561 Vs 17:34:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0060000 m, Delta X = 0.0005000 m VT = 0.000000535 +- 0.000000017 Vs 17:34:15 First Field Integral, Average and RMS of Measurements X0 = 0.0060000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000535 +- 0.000000017 Vs FI1 = 0.00107026 +- 0.00003338 Tm 17:34:15 Integrated Voltage Measurement... 17:34:16 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:34:23 Voltage Offset Correction: v_off_ini = -0.000001643 V, v_off_fin = -0.000001742 V 17:34:23 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000537 Vs 17:34:29 Voltage Offset Correction: v_off_ini = -0.000001678 V, v_off_fin = -0.000002164 V 17:34:29 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000450 Vs 17:34:30 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:34:36 Voltage Offset Correction: v_off_ini = -0.000001469 V, v_off_fin = -0.000001426 V 17:34:36 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:34:42 Voltage Offset Correction: v_off_ini = -0.000001539 V, v_off_fin = -0.000001284 V 17:34:42 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000558 Vs 17:34:43 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:34:49 Voltage Offset Correction: v_off_ini = -0.000001596 V, v_off_fin = -0.000002028 V 17:34:49 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000456 Vs 17:34:56 Voltage Offset Correction: v_off_ini = -0.000001683 V, v_off_fin = -0.000001203 V 17:34:56 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000515 Vs 17:34:56 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:35:02 Voltage Offset Correction: v_off_ini = -0.000001593 V, v_off_fin = -0.000001620 V 17:35:03 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000508 Vs 17:35:09 Voltage Offset Correction: v_off_ini = -0.000001783 V, v_off_fin = -0.000001608 V 17:35:09 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000553 Vs 17:35:09 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:35:16 Voltage Offset Correction: v_off_ini = -0.000001647 V, v_off_fin = -0.000001916 V 17:35:16 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000510 Vs 17:35:22 Voltage Offset Correction: v_off_ini = -0.000001742 V, v_off_fin = -0.000001523 V 17:35:22 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000549 Vs 17:35:23 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:35:29 Voltage Offset Correction: v_off_ini = -0.000001628 V, v_off_fin = -0.000001359 V 17:35:29 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000490 Vs 17:35:35 Voltage Offset Correction: v_off_ini = -0.000001501 V, v_off_fin = -0.000001349 V 17:35:35 Integrated Voltage Measurement X0 = 0.0065000 m, Delta X = -0.0005000 m VT = -0.000000526 Vs 17:35:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0065000 m, Delta X = 0.0005000 m VT = 0.000000515 +- 0.000000021 Vs 17:35:35 First Field Integral, Average and RMS of Measurements X0 = 0.0065000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000515 +- 0.000000021 Vs FI1 = 0.00103011 +- 0.00004242 Tm 17:35:35 Integrated Voltage Measurement... 17:35:36 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:35:43 Voltage Offset Correction: v_off_ini = -0.000001507 V, v_off_fin = -0.000001466 V 17:35:43 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000535 Vs 17:35:50 Voltage Offset Correction: v_off_ini = -0.000001618 V, v_off_fin = -0.000001707 V 17:35:50 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000599 Vs 17:35:50 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:35:57 Voltage Offset Correction: v_off_ini = -0.000001555 V, v_off_fin = -0.000001519 V 17:35:57 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000503 Vs 17:36:03 Voltage Offset Correction: v_off_ini = -0.000001505 V, v_off_fin = -0.000001822 V 17:36:03 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000578 Vs 17:36:04 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:36:10 Voltage Offset Correction: v_off_ini = -0.000001551 V, v_off_fin = -0.000001678 V 17:36:10 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000566 Vs 17:36:16 Voltage Offset Correction: v_off_ini = -0.000001384 V, v_off_fin = -0.000001369 V 17:36:16 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000514 Vs 17:36:17 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:36:23 Voltage Offset Correction: v_off_ini = -0.000001334 V, v_off_fin = -0.000001196 V 17:36:23 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 17:36:29 Voltage Offset Correction: v_off_ini = -0.000001304 V, v_off_fin = -0.000001131 V 17:36:29 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000533 Vs 17:36:30 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:36:36 Voltage Offset Correction: v_off_ini = -0.000001274 V, v_off_fin = -0.000001333 V 17:36:36 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:36:42 Voltage Offset Correction: v_off_ini = -0.000001636 V, v_off_fin = -0.000001688 V 17:36:42 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000482 Vs 17:36:43 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:36:49 Voltage Offset Correction: v_off_ini = -0.000001388 V, v_off_fin = -0.000001131 V 17:36:49 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:36:56 Voltage Offset Correction: v_off_ini = -0.000001564 V, v_off_fin = -0.000001587 V 17:36:56 Integrated Voltage Measurement X0 = 0.0070000 m, Delta X = -0.0005000 m VT = -0.000000566 Vs 17:36:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0070000 m, Delta X = 0.0005000 m VT = 0.000000538 +- 0.000000019 Vs 17:36:56 First Field Integral, Average and RMS of Measurements X0 = 0.0070000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000538 +- 0.000000019 Vs FI1 = 0.00107689 +- 0.00003707 Tm 17:36:56 Integrated Voltage Measurement... 17:36:56 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:37:04 Voltage Offset Correction: v_off_ini = -0.000001566 V, v_off_fin = -0.000001825 V 17:37:04 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000519 Vs 17:37:10 Voltage Offset Correction: v_off_ini = -0.000001554 V, v_off_fin = -0.000001358 V 17:37:10 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000595 Vs 17:37:11 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:37:17 Voltage Offset Correction: v_off_ini = -0.000001736 V, v_off_fin = -0.000001757 V 17:37:17 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000506 Vs 17:37:23 Voltage Offset Correction: v_off_ini = -0.000001540 V, v_off_fin = -0.000001186 V 17:37:23 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000567 Vs 17:37:24 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:37:30 Voltage Offset Correction: v_off_ini = -0.000001637 V, v_off_fin = -0.000001693 V 17:37:30 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000545 Vs 17:37:36 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = -0.000002065 V 17:37:36 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000597 Vs 17:37:37 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:37:43 Voltage Offset Correction: v_off_ini = -0.000001681 V, v_off_fin = -0.000001662 V 17:37:43 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000544 Vs 17:37:50 Voltage Offset Correction: v_off_ini = -0.000001738 V, v_off_fin = -0.000001760 V 17:37:50 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000554 Vs 17:37:50 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:37:57 Voltage Offset Correction: v_off_ini = -0.000001777 V, v_off_fin = -0.000001858 V 17:37:57 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000537 Vs 17:38:03 Voltage Offset Correction: v_off_ini = -0.000001496 V, v_off_fin = -0.000001363 V 17:38:03 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000563 Vs 17:38:03 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:38:10 Voltage Offset Correction: v_off_ini = -0.000001562 V, v_off_fin = -0.000001769 V 17:38:10 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000513 Vs 17:38:16 Voltage Offset Correction: v_off_ini = -0.000001466 V, v_off_fin = -0.000001651 V 17:38:16 Integrated Voltage Measurement X0 = 0.0075000 m, Delta X = -0.0005000 m VT = -0.000000542 Vs 17:38:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0075000 m, Delta X = 0.0005000 m VT = 0.000000549 +- 0.000000014 Vs 17:38:16 First Field Integral, Average and RMS of Measurements X0 = 0.0075000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000549 +- 0.000000014 Vs FI1 = 0.00109708 +- 0.00002802 Tm 17:38:16 Integrated Voltage Measurement... 17:38:17 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:38:24 Voltage Offset Correction: v_off_ini = -0.000001581 V, v_off_fin = -0.000001757 V 17:38:24 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000528 Vs 17:38:30 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = -0.000001279 V 17:38:30 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 17:38:31 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:38:37 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000001612 V 17:38:37 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000527 Vs 17:38:43 Voltage Offset Correction: v_off_ini = -0.000001738 V, v_off_fin = -0.000001842 V 17:38:43 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000547 Vs 17:38:44 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:38:50 Voltage Offset Correction: v_off_ini = -0.000001668 V, v_off_fin = -0.000001649 V 17:38:50 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 17:38:57 Voltage Offset Correction: v_off_ini = -0.000001535 V, v_off_fin = -0.000001515 V 17:38:57 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000537 Vs 17:38:57 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:39:04 Voltage Offset Correction: v_off_ini = -0.000001712 V, v_off_fin = -0.000001479 V 17:39:04 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000523 Vs 17:39:10 Voltage Offset Correction: v_off_ini = -0.000001321 V, v_off_fin = -0.000001437 V 17:39:10 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000540 Vs 17:39:10 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:39:17 Voltage Offset Correction: v_off_ini = -0.000001593 V, v_off_fin = -0.000001435 V 17:39:17 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000501 Vs 17:39:23 Voltage Offset Correction: v_off_ini = -0.000001509 V, v_off_fin = -0.000001465 V 17:39:23 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000551 Vs 17:39:24 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:39:30 Voltage Offset Correction: v_off_ini = -0.000001417 V, v_off_fin = -0.000001560 V 17:39:30 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000540 Vs 17:39:36 Voltage Offset Correction: v_off_ini = -0.000001398 V, v_off_fin = -0.000001495 V 17:39:36 Integrated Voltage Measurement X0 = 0.0080000 m, Delta X = -0.0005000 m VT = -0.000000555 Vs 17:39:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0080000 m, Delta X = 0.0005000 m VT = 0.000000538 +- 0.000000007 Vs 17:39:36 First Field Integral, Average and RMS of Measurements X0 = 0.0080000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000538 +- 0.000000007 Vs FI1 = 0.00107559 +- 0.00001462 Tm 17:39:36 Integrated Voltage Measurement... 17:39:37 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:39:44 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000001729 V 17:39:44 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:39:51 Voltage Offset Correction: v_off_ini = -0.000001540 V, v_off_fin = -0.000001594 V 17:39:51 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000569 Vs 17:39:51 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:39:58 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = -0.000001187 V 17:39:58 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000542 Vs 17:40:04 Voltage Offset Correction: v_off_ini = -0.000001624 V, v_off_fin = -0.000001645 V 17:40:04 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000562 Vs 17:40:05 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:40:11 Voltage Offset Correction: v_off_ini = -0.000001535 V, v_off_fin = -0.000001572 V 17:40:11 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000556 Vs 17:40:17 Voltage Offset Correction: v_off_ini = -0.000002024 V, v_off_fin = -0.000002138 V 17:40:17 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000531 Vs 17:40:18 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:40:24 Voltage Offset Correction: v_off_ini = -0.000001611 V, v_off_fin = -0.000001196 V 17:40:24 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000611 Vs 17:40:30 Voltage Offset Correction: v_off_ini = -0.000001704 V, v_off_fin = -0.000001671 V 17:40:30 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000544 Vs 17:40:31 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:40:37 Voltage Offset Correction: v_off_ini = -0.000001811 V, v_off_fin = -0.000001889 V 17:40:37 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000572 Vs 17:40:43 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000001665 V 17:40:43 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 17:40:44 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:40:50 Voltage Offset Correction: v_off_ini = -0.000001531 V, v_off_fin = -0.000001555 V 17:40:50 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000518 Vs 17:40:56 Voltage Offset Correction: v_off_ini = -0.000001706 V, v_off_fin = -0.000001601 V 17:40:56 Integrated Voltage Measurement X0 = 0.0085000 m, Delta X = -0.0005000 m VT = -0.000000575 Vs 17:40:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0085000 m, Delta X = 0.0005000 m VT = 0.000000553 +- 0.000000011 Vs 17:40:57 First Field Integral, Average and RMS of Measurements X0 = 0.0085000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000553 +- 0.000000011 Vs FI1 = 0.00110550 +- 0.00002290 Tm 17:40:57 Integrated Voltage Measurement... 17:40:57 Magnet Current for B9V2, Imag = 233.1018 A Vtrans = 2.331009 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:41:05 Voltage Offset Correction: v_off_ini = -0.000001752 V, v_off_fin = -0.000001951 V 17:41:05 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000542 Vs 17:41:11 Voltage Offset Correction: v_off_ini = -0.000001701 V, v_off_fin = -0.000001646 V 17:41:11 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000547 Vs 17:41:12 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:41:18 Voltage Offset Correction: v_off_ini = -0.000001715 V, v_off_fin = -0.000001404 V 17:41:18 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000505 Vs 17:41:24 Voltage Offset Correction: v_off_ini = -0.000001662 V, v_off_fin = -0.000001824 V 17:41:24 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000549 Vs 17:41:25 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:41:31 Voltage Offset Correction: v_off_ini = -0.000001774 V, v_off_fin = -0.000001664 V 17:41:31 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000557 Vs 17:41:37 Voltage Offset Correction: v_off_ini = -0.000001718 V, v_off_fin = -0.000001753 V 17:41:37 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000523 Vs 17:41:38 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:41:44 Voltage Offset Correction: v_off_ini = -0.000001631 V, v_off_fin = -0.000001683 V 17:41:44 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000530 Vs 17:41:50 Voltage Offset Correction: v_off_ini = -0.000001591 V, v_off_fin = -0.000001685 V 17:41:50 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000529 Vs 17:41:51 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:41:57 Voltage Offset Correction: v_off_ini = -0.000001370 V, v_off_fin = -0.000001253 V 17:41:57 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000528 Vs 17:42:04 Voltage Offset Correction: v_off_ini = -0.000001378 V, v_off_fin = -0.000001426 V 17:42:04 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000554 Vs 17:42:04 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:42:10 Voltage Offset Correction: v_off_ini = -0.000001581 V, v_off_fin = -0.000002059 V 17:42:11 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000541 Vs 17:42:17 Voltage Offset Correction: v_off_ini = -0.000001509 V, v_off_fin = -0.000001454 V 17:42:17 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0005000 m VT = -0.000000555 Vs 17:42:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0090000 m, Delta X = 0.0005000 m VT = 0.000000538 +- 0.000000008 Vs 17:42:17 First Field Integral, Average and RMS of Measurements X0 = 0.0090000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000538 +- 0.000000008 Vs FI1 = 0.00107634 +- 0.00001554 Tm 17:42:17 Integrated Voltage Measurement... 17:42:18 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:42:25 Voltage Offset Correction: v_off_ini = -0.000001373 V, v_off_fin = -0.000001232 V 17:42:25 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000556 Vs 17:42:31 Voltage Offset Correction: v_off_ini = -0.000001579 V, v_off_fin = -0.000002021 V 17:42:31 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000511 Vs 17:42:32 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:42:38 Voltage Offset Correction: v_off_ini = -0.000001530 V, v_off_fin = -0.000001849 V 17:42:38 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000533 Vs 17:42:43 Voltage Offset Correction: v_off_ini = -0.000001436 V, v_off_fin = -0.000001488 V 17:42:43 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000550 Vs 17:42:44 Magnet Current for B9V2, Imag = 233.1006 A Vtrans = 2.330996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:42:50 Voltage Offset Correction: v_off_ini = -0.000001461 V, v_off_fin = -0.000001245 V 17:42:50 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000578 Vs 17:42:56 Voltage Offset Correction: v_off_ini = -0.000001447 V, v_off_fin = -0.000001320 V 17:42:56 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000565 Vs 17:42:57 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:43:03 Voltage Offset Correction: v_off_ini = -0.000001462 V, v_off_fin = -0.000001380 V 17:43:03 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000549 Vs 17:43:09 Voltage Offset Correction: v_off_ini = -0.000001569 V, v_off_fin = -0.000001497 V 17:43:09 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000603 Vs 17:43:10 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:43:16 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = -0.000001704 V 17:43:16 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000569 Vs 17:43:22 Voltage Offset Correction: v_off_ini = -0.000001530 V, v_off_fin = -0.000001473 V 17:43:22 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000561 Vs 17:43:23 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:43:29 Voltage Offset Correction: v_off_ini = -0.000001687 V, v_off_fin = -0.000001767 V 17:43:29 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000502 Vs 17:43:36 Voltage Offset Correction: v_off_ini = -0.000001615 V, v_off_fin = -0.000001466 V 17:43:36 Integrated Voltage Measurement X0 = 0.0095000 m, Delta X = -0.0005000 m VT = -0.000000545 Vs 17:43:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0095000 m, Delta X = 0.0005000 m VT = 0.000000552 +- 0.000000020 Vs 17:43:36 First Field Integral, Average and RMS of Measurements X0 = 0.0095000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000552 +- 0.000000020 Vs FI1 = 0.00110364 +- 0.00003974 Tm 17:43:36 Integrated Voltage Measurement... 17:43:37 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:43:44 Voltage Offset Correction: v_off_ini = -0.000001432 V, v_off_fin = -0.000001606 V 17:43:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 17:43:50 Voltage Offset Correction: v_off_ini = -0.000001760 V, v_off_fin = -0.000001845 V 17:43:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000517 Vs 17:43:51 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:43:57 Voltage Offset Correction: v_off_ini = -0.000001569 V, v_off_fin = -0.000001417 V 17:43:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000519 Vs 17:44:03 Voltage Offset Correction: v_off_ini = -0.000001699 V, v_off_fin = -0.000001653 V 17:44:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000591 Vs 17:44:04 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:44:10 Voltage Offset Correction: v_off_ini = -0.000001732 V, v_off_fin = -0.000001739 V 17:44:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000553 Vs 17:44:16 Voltage Offset Correction: v_off_ini = -0.000001607 V, v_off_fin = -0.000001857 V 17:44:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000558 Vs 17:44:17 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:44:23 Voltage Offset Correction: v_off_ini = -0.000001493 V, v_off_fin = -0.000001541 V 17:44:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000538 Vs 17:44:30 Voltage Offset Correction: v_off_ini = -0.000001658 V, v_off_fin = -0.000001781 V 17:44:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000579 Vs 17:44:30 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:44:37 Voltage Offset Correction: v_off_ini = -0.000001752 V, v_off_fin = -0.000001632 V 17:44:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000584 Vs 17:44:43 Voltage Offset Correction: v_off_ini = -0.000001826 V, v_off_fin = -0.000001229 V 17:44:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000549 Vs 17:44:44 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:44:50 Voltage Offset Correction: v_off_ini = -0.000001568 V, v_off_fin = -0.000001647 V 17:44:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000570 Vs 17:44:56 Voltage Offset Correction: v_off_ini = -0.000001745 V, v_off_fin = -0.000001701 V 17:44:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0005000 m VT = -0.000000596 Vs 17:44:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0005000 m VT = 0.000000558 +- 0.000000015 Vs 17:44:56 First Field Integral, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000558 +- 0.000000015 Vs FI1 = 0.00111686 +- 0.00003073 Tm 17:44:56 Integrated Voltage Measurement... 17:44:57 Magnet Current for B9V2, Imag = 233.1016 A Vtrans = 2.331006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:45:04 Voltage Offset Correction: v_off_ini = -0.000001691 V, v_off_fin = -0.000001496 V 17:45:04 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000540 Vs 17:45:10 Voltage Offset Correction: v_off_ini = -0.000001511 V, v_off_fin = -0.000001546 V 17:45:10 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000582 Vs 17:45:11 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:45:17 Voltage Offset Correction: v_off_ini = -0.000001485 V, v_off_fin = -0.000001718 V 17:45:17 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000550 Vs 17:45:24 Voltage Offset Correction: v_off_ini = -0.000001866 V, v_off_fin = -0.000001438 V 17:45:24 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000603 Vs 17:45:24 Magnet Current for B9V2, Imag = 233.1008 A Vtrans = 2.330999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:45:30 Voltage Offset Correction: v_off_ini = -0.000001417 V, v_off_fin = -0.000001446 V 17:45:31 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000570 Vs 17:45:37 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000001359 V 17:45:37 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000580 Vs 17:45:37 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:45:44 Voltage Offset Correction: v_off_ini = -0.000001564 V, v_off_fin = -0.000001542 V 17:45:44 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000549 Vs 17:45:50 Voltage Offset Correction: v_off_ini = -0.000001751 V, v_off_fin = -0.000001766 V 17:45:50 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000570 Vs 17:45:51 Magnet Current for B9V2, Imag = 233.1018 A Vtrans = 2.331009 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:45:57 Voltage Offset Correction: v_off_ini = -0.000001155 V, v_off_fin = -0.000001321 V 17:45:57 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000559 Vs 17:46:03 Voltage Offset Correction: v_off_ini = -0.000001438 V, v_off_fin = -0.000001055 V 17:46:03 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000584 Vs 17:46:04 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:46:10 Voltage Offset Correction: v_off_ini = -0.000001554 V, v_off_fin = -0.000001098 V 17:46:10 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000614 Vs 17:46:16 Voltage Offset Correction: v_off_ini = -0.000001550 V, v_off_fin = -0.000001245 V 17:46:16 Integrated Voltage Measurement X0 = 0.0105000 m, Delta X = -0.0005000 m VT = -0.000000583 Vs 17:46:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0105000 m, Delta X = 0.0005000 m VT = 0.000000574 +- 0.000000013 Vs 17:46:16 First Field Integral, Average and RMS of Measurements X0 = 0.0105000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000574 +- 0.000000013 Vs FI1 = 0.00114719 +- 0.00002571 Tm 17:46:16 Integrated Voltage Measurement... 17:46:17 Magnet Current for B9V2, Imag = 233.1016 A Vtrans = 2.331006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:46:24 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = -0.000001143 V 17:46:24 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000546 Vs 17:46:31 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = -0.000001346 V 17:46:31 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000547 Vs 17:46:31 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:46:38 Voltage Offset Correction: v_off_ini = -0.000001608 V, v_off_fin = -0.000001417 V 17:46:38 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000571 Vs 17:46:44 Voltage Offset Correction: v_off_ini = -0.000001658 V, v_off_fin = -0.000001555 V 17:46:44 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000539 Vs 17:46:44 Magnet Current for B9V2, Imag = 233.1017 A Vtrans = 2.331008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:46:51 Voltage Offset Correction: v_off_ini = -0.000001474 V, v_off_fin = -0.000001482 V 17:46:51 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000574 Vs 17:46:57 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000001212 V 17:46:57 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000580 Vs 17:46:58 Magnet Current for B9V2, Imag = 233.1017 A Vtrans = 2.331008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:47:04 Voltage Offset Correction: v_off_ini = -0.000001540 V, v_off_fin = -0.000001575 V 17:47:04 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:47:10 Voltage Offset Correction: v_off_ini = -0.000001689 V, v_off_fin = -0.000001559 V 17:47:10 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000586 Vs 17:47:11 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:47:17 Voltage Offset Correction: v_off_ini = -0.000001679 V, v_off_fin = -0.000001494 V 17:47:17 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000539 Vs 17:47:23 Voltage Offset Correction: v_off_ini = -0.000001622 V, v_off_fin = -0.000001453 V 17:47:23 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000582 Vs 17:47:24 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:47:30 Voltage Offset Correction: v_off_ini = -0.000001638 V, v_off_fin = -0.000001699 V 17:47:30 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000520 Vs 17:47:37 Voltage Offset Correction: v_off_ini = -0.000001710 V, v_off_fin = -0.000002067 V 17:47:37 Integrated Voltage Measurement X0 = 0.0110000 m, Delta X = -0.0005000 m VT = -0.000000609 Vs 17:47:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0110000 m, Delta X = 0.0005000 m VT = 0.000000560 +- 0.000000009 Vs 17:47:37 First Field Integral, Average and RMS of Measurements X0 = 0.0110000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000560 +- 0.000000009 Vs FI1 = 0.00112047 +- 0.00001857 Tm 17:47:37 Integrated Voltage Measurement... 17:47:37 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:47:45 Voltage Offset Correction: v_off_ini = -0.000001598 V, v_off_fin = -0.000001672 V 17:47:45 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000584 Vs 17:47:51 Voltage Offset Correction: v_off_ini = -0.000001881 V, v_off_fin = -0.000002131 V 17:47:51 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000580 Vs 17:47:52 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:47:58 Voltage Offset Correction: v_off_ini = -0.000001641 V, v_off_fin = -0.000001658 V 17:47:58 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:48:04 Voltage Offset Correction: v_off_ini = -0.000001444 V, v_off_fin = -0.000001430 V 17:48:04 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000610 Vs 17:48:05 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:48:11 Voltage Offset Correction: v_off_ini = -0.000001621 V, v_off_fin = -0.000001887 V 17:48:11 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000535 Vs 17:48:17 Voltage Offset Correction: v_off_ini = -0.000001486 V, v_off_fin = -0.000001348 V 17:48:17 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000591 Vs 17:48:18 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:48:24 Voltage Offset Correction: v_off_ini = -0.000001647 V, v_off_fin = -0.000001661 V 17:48:24 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000568 Vs 17:48:31 Voltage Offset Correction: v_off_ini = -0.000001547 V, v_off_fin = -0.000001197 V 17:48:31 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000604 Vs 17:48:31 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:48:38 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001256 V 17:48:38 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 17:48:44 Voltage Offset Correction: v_off_ini = -0.000001563 V, v_off_fin = -0.000001698 V 17:48:44 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000556 Vs 17:48:45 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:48:51 Voltage Offset Correction: v_off_ini = -0.000001509 V, v_off_fin = -0.000001409 V 17:48:51 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000548 Vs 17:48:57 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000001701 V 17:48:57 Integrated Voltage Measurement X0 = 0.0115000 m, Delta X = -0.0005000 m VT = -0.000000521 Vs 17:48:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0115000 m, Delta X = 0.0005000 m VT = 0.000000565 +- 0.000000018 Vs 17:48:57 First Field Integral, Average and RMS of Measurements X0 = 0.0115000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000565 +- 0.000000018 Vs FI1 = 0.00112926 +- 0.00003562 Tm 17:48:57 Integrated Voltage Measurement... 17:48:58 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:49:05 Voltage Offset Correction: v_off_ini = -0.000001652 V, v_off_fin = -0.000001920 V 17:49:05 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000516 Vs 17:49:11 Voltage Offset Correction: v_off_ini = -0.000001333 V, v_off_fin = -0.000001345 V 17:49:11 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000583 Vs 17:49:12 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:49:18 Voltage Offset Correction: v_off_ini = -0.000001553 V, v_off_fin = -0.000001692 V 17:49:18 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000538 Vs 17:49:25 Voltage Offset Correction: v_off_ini = -0.000001482 V, v_off_fin = -0.000001677 V 17:49:25 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000551 Vs 17:49:25 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:49:32 Voltage Offset Correction: v_off_ini = -0.000001415 V, v_off_fin = -0.000001601 V 17:49:32 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 17:49:38 Voltage Offset Correction: v_off_ini = -0.000001516 V, v_off_fin = -0.000001674 V 17:49:38 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000555 Vs 17:49:39 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:49:45 Voltage Offset Correction: v_off_ini = -0.000001447 V, v_off_fin = -0.000001382 V 17:49:45 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000552 Vs 17:49:51 Voltage Offset Correction: v_off_ini = -0.000001429 V, v_off_fin = -0.000001462 V 17:49:51 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000517 Vs 17:49:52 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:49:58 Voltage Offset Correction: v_off_ini = -0.000001453 V, v_off_fin = -0.000001297 V 17:49:58 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000508 Vs 17:50:04 Voltage Offset Correction: v_off_ini = -0.000001286 V, v_off_fin = -0.000001417 V 17:50:04 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000527 Vs 17:50:05 Magnet Current for B9V2, Imag = 233.1016 A Vtrans = 2.331006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:50:11 Voltage Offset Correction: v_off_ini = -0.000001516 V, v_off_fin = -0.000001651 V 17:50:11 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000570 Vs 17:50:17 Voltage Offset Correction: v_off_ini = -0.000001456 V, v_off_fin = -0.000001504 V 17:50:17 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0005000 m VT = -0.000000531 Vs 17:50:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0120000 m, Delta X = 0.0005000 m VT = 0.000000541 +- 0.000000012 Vs 17:50:17 First Field Integral, Average and RMS of Measurements X0 = 0.0120000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000541 +- 0.000000012 Vs FI1 = 0.00108250 +- 0.00002411 Tm 17:50:17 Integrated Voltage Measurement... 17:50:18 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:50:25 Voltage Offset Correction: v_off_ini = -0.000001484 V, v_off_fin = -0.000001332 V 17:50:25 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000513 Vs 17:50:32 Voltage Offset Correction: v_off_ini = -0.000001144 V, v_off_fin = -0.000001049 V 17:50:32 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000498 Vs 17:50:32 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:50:39 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000001282 V 17:50:39 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000529 Vs 17:50:45 Voltage Offset Correction: v_off_ini = -0.000001396 V, v_off_fin = -0.000001490 V 17:50:45 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000532 Vs 17:50:45 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:50:52 Voltage Offset Correction: v_off_ini = -0.000001528 V, v_off_fin = -0.000001446 V 17:50:52 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000489 Vs 17:50:58 Voltage Offset Correction: v_off_ini = -0.000001385 V, v_off_fin = -0.000001554 V 17:50:58 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000544 Vs 17:50:59 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:51:05 Voltage Offset Correction: v_off_ini = -0.000001250 V, v_off_fin = -0.000001075 V 17:51:05 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:51:11 Voltage Offset Correction: v_off_ini = -0.000001542 V, v_off_fin = -0.000001365 V 17:51:11 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000557 Vs 17:51:12 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:51:18 Voltage Offset Correction: v_off_ini = -0.000001488 V, v_off_fin = -0.000001375 V 17:51:18 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000507 Vs 17:51:24 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001409 V 17:51:24 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000536 Vs 17:51:25 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:51:31 Voltage Offset Correction: v_off_ini = -0.000001413 V, v_off_fin = -0.000001555 V 17:51:31 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000554 Vs 17:51:37 Voltage Offset Correction: v_off_ini = -0.000001457 V, v_off_fin = -0.000001258 V 17:51:37 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0005000 m VT = -0.000000546 Vs 17:51:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0005000 m VT = 0.000000528 +- 0.000000015 Vs 17:51:38 First Field Integral, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000528 +- 0.000000015 Vs FI1 = 0.00105636 +- 0.00003064 Tm 17:51:38 Integrated Voltage Measurement... 17:51:38 Magnet Current for B9V2, Imag = 233.1007 A Vtrans = 2.330997 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:51:46 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000001238 V 17:51:46 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000511 Vs 17:51:52 Voltage Offset Correction: v_off_ini = -0.000001462 V, v_off_fin = -0.000001339 V 17:51:52 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000549 Vs 17:51:53 Magnet Current for B9V2, Imag = 233.1017 A Vtrans = 2.331008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:51:59 Voltage Offset Correction: v_off_ini = -0.000001643 V, v_off_fin = -0.000001569 V 17:51:59 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000531 Vs 17:52:05 Voltage Offset Correction: v_off_ini = -0.000001602 V, v_off_fin = -0.000001626 V 17:52:05 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000511 Vs 17:52:06 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:52:12 Voltage Offset Correction: v_off_ini = -0.000001368 V, v_off_fin = -0.000001063 V 17:52:12 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000554 Vs 17:52:18 Voltage Offset Correction: v_off_ini = -0.000001544 V, v_off_fin = -0.000001622 V 17:52:18 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000492 Vs 17:52:19 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:52:25 Voltage Offset Correction: v_off_ini = -0.000001638 V, v_off_fin = -0.000001670 V 17:52:25 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000506 Vs 17:52:31 Voltage Offset Correction: v_off_ini = -0.000001528 V, v_off_fin = -0.000001596 V 17:52:31 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000485 Vs 17:52:32 Magnet Current for B9V2, Imag = 233.1015 A Vtrans = 2.331005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:52:38 Voltage Offset Correction: v_off_ini = -0.000001510 V, v_off_fin = -0.000001454 V 17:52:38 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000498 Vs 17:52:44 Voltage Offset Correction: v_off_ini = -0.000001738 V, v_off_fin = -0.000001615 V 17:52:44 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000496 Vs 17:52:45 Magnet Current for B9V2, Imag = 233.1011 A Vtrans = 2.331001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:52:51 Voltage Offset Correction: v_off_ini = -0.000001574 V, v_off_fin = -0.000001651 V 17:52:51 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000499 Vs 17:52:58 Voltage Offset Correction: v_off_ini = -0.000001486 V, v_off_fin = -0.000001765 V 17:52:58 Integrated Voltage Measurement X0 = 0.0130000 m, Delta X = -0.0005000 m VT = -0.000000470 Vs 17:52:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0130000 m, Delta X = 0.0005000 m VT = 0.000000508 +- 0.000000017 Vs 17:52:58 First Field Integral, Average and RMS of Measurements X0 = 0.0130000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000508 +- 0.000000017 Vs FI1 = 0.00101675 +- 0.00003395 Tm 17:52:58 Integrated Voltage Measurement... 17:52:58 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:53:06 Voltage Offset Correction: v_off_ini = -0.000001520 V, v_off_fin = -0.000001446 V 17:53:06 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000487 Vs 17:53:12 Voltage Offset Correction: v_off_ini = -0.000001646 V, v_off_fin = -0.000001507 V 17:53:12 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000468 Vs 17:53:13 Magnet Current for B9V2, Imag = 233.1017 A Vtrans = 2.331008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:53:19 Voltage Offset Correction: v_off_ini = -0.000001744 V, v_off_fin = -0.000001853 V 17:53:19 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000462 Vs 17:53:25 Voltage Offset Correction: v_off_ini = -0.000001460 V, v_off_fin = -0.000001271 V 17:53:25 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000459 Vs 17:53:26 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:53:32 Voltage Offset Correction: v_off_ini = -0.000001560 V, v_off_fin = -0.000001360 V 17:53:32 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000472 Vs 17:53:38 Voltage Offset Correction: v_off_ini = -0.000001687 V, v_off_fin = -0.000001674 V 17:53:38 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000469 Vs 17:53:39 Magnet Current for B9V2, Imag = 233.1016 A Vtrans = 2.331006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:53:45 Voltage Offset Correction: v_off_ini = -0.000001621 V, v_off_fin = -0.000001529 V 17:53:45 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000480 Vs 17:53:51 Voltage Offset Correction: v_off_ini = -0.000001458 V, v_off_fin = -0.000001584 V 17:53:51 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000495 Vs 17:53:52 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:53:58 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000001881 V 17:53:58 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000498 Vs 17:54:04 Voltage Offset Correction: v_off_ini = -0.000001606 V, v_off_fin = -0.000002027 V 17:54:04 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000507 Vs 17:54:05 Magnet Current for B9V2, Imag = 233.1017 A Vtrans = 2.331008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:54:11 Voltage Offset Correction: v_off_ini = -0.000001843 V, v_off_fin = -0.000001627 V 17:54:11 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000466 Vs 17:54:18 Voltage Offset Correction: v_off_ini = -0.000001362 V, v_off_fin = -0.000001240 V 17:54:18 Integrated Voltage Measurement X0 = 0.0135000 m, Delta X = -0.0005000 m VT = -0.000000485 Vs 17:54:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0135000 m, Delta X = 0.0005000 m VT = 0.000000479 +- 0.000000013 Vs 17:54:18 First Field Integral, Average and RMS of Measurements X0 = 0.0135000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000479 +- 0.000000013 Vs FI1 = 0.00095811 +- 0.00002642 Tm 17:54:18 Integrated Voltage Measurement... 17:54:19 Magnet Current for B9V2, Imag = 233.1015 A Vtrans = 2.331005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:54:26 Voltage Offset Correction: v_off_ini = -0.000001605 V, v_off_fin = -0.000001832 V 17:54:26 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000437 Vs 17:54:32 Voltage Offset Correction: v_off_ini = -0.000001803 V, v_off_fin = -0.000001932 V 17:54:32 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000401 Vs 17:54:33 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:54:39 Voltage Offset Correction: v_off_ini = -0.000001700 V, v_off_fin = -0.000001894 V 17:54:39 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000397 Vs 17:54:45 Voltage Offset Correction: v_off_ini = -0.000001652 V, v_off_fin = -0.000001481 V 17:54:45 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000435 Vs 17:54:46 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:54:52 Voltage Offset Correction: v_off_ini = -0.000001550 V, v_off_fin = -0.000001559 V 17:54:52 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000415 Vs 17:54:58 Voltage Offset Correction: v_off_ini = -0.000001438 V, v_off_fin = -0.000001512 V 17:54:58 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000429 Vs 17:54:59 Magnet Current for B9V2, Imag = 233.1010 A Vtrans = 2.331000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:55:05 Voltage Offset Correction: v_off_ini = -0.000001548 V, v_off_fin = -0.000001535 V 17:55:05 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000410 Vs 17:55:11 Voltage Offset Correction: v_off_ini = -0.000001776 V, v_off_fin = -0.000002351 V 17:55:11 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000365 Vs 17:55:12 Magnet Current for B9V2, Imag = 233.1013 A Vtrans = 2.331004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:55:18 Voltage Offset Correction: v_off_ini = -0.000001385 V, v_off_fin = -0.000001364 V 17:55:18 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000422 Vs 17:55:25 Voltage Offset Correction: v_off_ini = -0.000001608 V, v_off_fin = -0.000001523 V 17:55:25 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000429 Vs 17:55:25 Magnet Current for B9V2, Imag = 233.1012 A Vtrans = 2.331002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000966 A 17:55:32 Voltage Offset Correction: v_off_ini = -0.000001761 V, v_off_fin = -0.000001857 V 17:55:32 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000420 Vs 17:55:38 Voltage Offset Correction: v_off_ini = -0.000001706 V, v_off_fin = -0.000001671 V 17:55:38 Integrated Voltage Measurement X0 = 0.0140000 m, Delta X = -0.0005000 m VT = -0.000000372 Vs 17:55:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0140000 m, Delta X = 0.0005000 m VT = 0.000000411 +- 0.000000014 Vs 17:55:38 First Field Integral, Average and RMS of Measurements X0 = 0.0140000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000411 +- 0.000000014 Vs FI1 = 0.00082223 +- 0.00002823 Tm 17:55:43 Position moved: 0.000000 m 17:55:46 Position moved: 0.000000 m 17:55:54 Move Stages, x_position = 0.000000 m, y_position = 0.000000 m 17:55:54 Magnet system B9V2 current ramping to 0.0000 A...