SLAC Magnetic Measurements Date: 05-06-1998 Time: 09:21:59 Project: PEP2INT Magnet Type: DIPOLE Magnet Name (Serial #): B1R Bar Code Number: Test Stand: 5 Measurement System: STRETCHED WIRE Operator: zw Run Number: 1 Comment: scale = 13.0, roll determination 09:22:05 Integrated Voltage Measurement... 09:22:07 Wire moved to X = -.5 cm 09:22:12 Wire moved by DX = 1 cm 09:22:20 X0 = 0 cm, dx = 1 cm, VT = 3.529388E-03 VS 09:22:22 Wire moved to X = .5 cm 09:22:27 Wire moved by DX = -1 cm 09:22:35 X0 = 0 cm, dx = -1 cm, VT = -3.508096E-03 VS 09:22:37 Wire moved to X = -.5 cm 09:22:42 Wire moved by DX = 1 cm 09:22:50 X0 = 0 cm, dx = 1 cm, VT = 3.522622E-03 VS 09:22:51 Wire moved to X = .5 cm 09:22:56 Wire moved by DX = -1 cm 09:23:04 X0 = 0 cm, dx = -1 cm, VT = -3.516883E-03 VS 09:23:06 Wire moved to X = -.5 cm 09:23:11 Wire moved by DX = 1 cm 09:23:19 X0 = 0 cm, dx = 1 cm, VT = 3.52117E-03 VS 09:23:20 Wire moved to X = .5 cm 09:23:26 Wire moved by DX = -1 cm 09:23:34 X0 = 0 cm, dx = -1 cm, VT = -3.516642E-03 VS 09:23:35 Wire moved to X = -.5 cm 09:23:40 Wire moved by DX = 1 cm 09:23:48 X0 = 0 cm, dx = 1 cm, VT = 3.518904E-03 VS 09:23:50 Wire moved to X = .5 cm 09:23:55 Wire moved by DX = -1 cm 09:24:03 X0 = 0 cm, dx = -1 cm, VT = -3.516953E-03 VS 09:24:03 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 3.518832E-03 +- 6.476124E-07 VS (= Tm^2) 09:24:03 The integrated field strength is BL = 3.518832E-02 +- 6.476124E-06 Tm 09:24:05 Wire moved to X = 0 cm