SLAC Magnetic Measurements Date: 09-01-2011 Time: 10:51:02 Project: NSLSII Magnet Type: Quad Magnet Name: MG_QDP_5200#0 Serial Number: Run Number: 2 & 3 Measurement Device: 10 wire Operator: sda Comment: Mean and Standard Deviation for wireplt.ru2 and ru3 for coil callibration. Standardization: 5 cycles from 5.0 A to 175.0 A to 5.0 A Test Currents (A): 175.0 175.0 175.0 175.0 Integrated Gradient Distance the wire was to be moved = 0.006000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 Imag sigImag GL sigGL GL/I sigGL/I (A) (T) (T/A) ----------+---------- ----------+---------- ----------+---------- 175.05797 0.00018 -2.15610 0.00035 -0.012316 0.000002 175.05813 0.00017 -2.15790 0.00025 -0.012327 0.000001 175.05838 0.00010 -2.15761 0.00036 -0.012325 0.000002 175.05880 0.00014 -2.15765 0.00030 -0.012325 0.000002 175.05818 0.00020 -2.15775 0.00046 -0.012326 0.000003 175.05965 0.00019 -2.15779 0.00025 -0.012326 0.000001 175.06077 0.00016 -2.15763 0.00047 -0.012325 0.000003 175.06141 0.00011 -2.15744 0.00032 -0.012324 0.000002 175.05916 0.00131 -2.15748 0.00058 -0.0123243 3.269529e-006 Mean +/- Stdev