SLAC Magnetic Measurements Date: 05-10-2011 Time: 09:11:04 Project: LCLS Device Type: Hall probe Data Type: Serial Number: SENTRON_441 Run Number: 230 Measurement Type: Reference magnet Operator: YL Comment: S/N37 Run 66 ; re-calibrated voltmeter 5.755274 -0.369721 0.067375 -0.369720 0.000749 -0.369722 5.755145 -0.369716 0.067721 -0.369727 0.000770 -0.369725 Field = -0.369017 Adjusted for T = 19.9500 Field = -0.368999 5.755284 -0.369705 0.066851 -0.369708 0.000921 -0.369702 5.755029 -0.369701 0.067330 -0.369721 0.000613 -0.369720 Field = -0.369019 Adjusted for T = 19.9600 Field = -0.369004 5.755159 -0.369718 0.067319 -0.369719 0.000871 -0.369716 5.755187 -0.369716 0.067552 -0.369717 0.000714 -0.369726 Field = -0.369042 Not adjusted for T