SLAC Magnetic Measurements Date: 04-13-2011 Time: 09:40:46 Project: LCLS Device Type: Hall probe Data Type: Serial Number: SENTRON_441 Run Number: 225 Measurement Type: Reference magnet Operator: YL Comment: S/N13 Run 66 5.755125 -0.369690 0.067465 -0.369693 0.000690 -0.369692 5.755211 -0.369700 0.067554 -0.369705 0.000829 -0.369698 Field = -0.368999 Adjusted for T = 19.9700 Field = -0.368988 5.755125 -0.369703 0.067474 -0.369708 0.000771 -0.369710 5.755092 -0.369715 0.067527 -0.369712 0.000768 -0.369712 Field = -0.369002 Adjusted for T = 19.9600 Field = -0.368988 5.754986 -0.369719 0.067439 -0.369715 0.000708 -0.369722 5.755066 -0.369731 0.067470 -0.369726 0.000744 -0.369727 Field = -0.369007 Not adjusted for T